DEVELOPMENT REGULATIONS
Table 2A. Site Regulations by District: Residential (20.24.020) | |||||
|---|---|---|---|---|---|
Standard | Zoning District | ||||
R-1 | R-2 | R-3(20) | R-4(1) | RHD(2) | |
Maximum Density (dwelling units/acre) | 12 (3)(10) | 35 | 63(21) | 87 | 6 or 9(4) |
Maximum FAR (floor area/lot area ratio) | |||||
Single-family dwelling Multifamily dwelling | 0.55(5) | 0.55(5) | 0.55(5) 1.50/2.0(6)(7) | N/A | 0.50(8) |
Minimum Lot Size (square feet)(10) | |||||
Single-family 2-family Multiple-family Public/quasi-public | 3,750 N/A N/A 10,000 | 3,750 3,750 3,750 10,000 | 3,750 3,750 3,750 10,000 | 5,000(8) | |
Minimum Lot Width (feet) | |||||
Single-family 2-family Multiple-family Public/quasi-public | 35 N/A N/A 75 | 35 37.5 37.5 75 | 50 50 50 75 | 50(8) | |
Maximum Lot Coverage (% of lot area) | N/A | 50% | 50% | ||
Single-family 2-family Multiple-family Public/quasi-public | 50% N/A N/A(11) | 50% 50% 50%(11) | 50% 50% 70%(11) | 40%(8) | |
Maximum Building Height (feet) | |||||
Single-family 2-family Multiple-family Public/quasi-public | 28(12) N/A N/A 35 | 28(12) 35/28(14) 35/28(14) 35 | 35 35/28(14) 50/35/28(14) 35 | (13)(8) | |
Minimum Yard Setbacks (feet) | |||||
Single-, Two-, Multiple-family: | |||||
Front | 15(15) | 15(15) | 15(15) | 15(8)(15) | |
Side, interior | (16) | (16) | (16) | (17)(8) | |
Side, exterior | 7.5 | 7.5(18) | 7.5(18) | 17) (8) | |
Rear | 20 | 15 | 15 | 20(8) | |
Single-family second-story addition | (19) | (19) | (19) | ||
Public/quasi-public | (11) | (11) | (11) | ||
Maximum Fence Height | See Subsection 20.24.110 | ||||
Minimum Usable Open Space (multifamily dwellings) | See Subsection 20.24.090 | ||||
Accessory Buildings | See Subsection 20.24.130 | ||||
Notes, Table 2A: | |||
|---|---|---|---|
1. In R-4 District, site regulations not specified will be determined by the Planning and Zoning Commission on consideration of an application for a use permit. Existing densities of developed sites are deemed to be conforming, but existing densities will not be permitted to be increased above the maximum density permitted in the R-3 District. | |||
2. In the RHD District, all multiple-family development, and any single-family development which comprises two or more acres of land area, shall be processed as a development plan under planned unit development procedures specified in Subsection 20.100.060. See Subsection 20.24.040 for development regulations applicable to the RHD District in addition to the regulations stated in this table. | |||
3. The higher maximum density stated in the General Plan takes into account the pre-existence of substandard nonconforming lots. | |||
4. The Albany General Plan divides the area subject to the RHD District into two density classifications: Low density = 6 dwelling units/acre. High density = 9 dwelling units/acre. Through the planned unit development process (Subsection 20.100.060), allowable density may be reduced according to slope density restrictions and/or the presence of natural topographic features. The City may permit the transfer of density from one portion of a development site to another, upon making a finding that the density transfer is necessary to accomplish the purposes of this chapter. | |||
5. The Planning and Zoning Commission may approve a floor/area ratio of up to 0.60 based on determination that any of the following conditions exist: (a) The site is of such a size that application of the 0.55 floor/area ratio would result in a gross square footage of less than 1,500 square feet. (b) The site is in a zone other than R-1 and buildings on any surrounding properties exceed FAR 0.60, and the higher FAR is warranted by considerations of harmonious transition among properties. (c) The proposed design has architectural features that contribute substantially to neighborhood quality, which could not be achieved in a smaller building mass. | |||
6. FAR may be increased to 1.75 where open space is provided at twice the minimum requirement stated in Subsection 20.24.090.B. As an incentive for lot consolidation, FAR may be increased to 2.0 within the San Pablo Avenue Specific Plan planning area on through-lots extending to San Pablo Avenue. | |||
7. Enclosed off-street parking shall be included in the calculation of the FAR, except that such parking area that is located entirely below grade may be excluded. (See Subsection 20.24.050.C.) | |||
8. Applies to single-family development in RHD District on land comprising less than two acres. Also shall be considered to be the minimum standards required for development of a single-family planned unit development on two acres or more, except that modified development standards may be approved if deemed appropriate by the Planning and Zoning Commission and City Council. | |||
9. (Reserved) | |||
10. Existing lots which do not meet minimum area standards may be developed or improved as provided in § 20.44, Nonconforming Uses, Structures and Lots. | |||
11. For public and quasi-public uses, lot coverage and yard setbacks will be determined by the Planning and Zoning Commission on consideration of an application for a use permit or design review. | |||
12. Planning and Zoning Commission, subject to design review criteria, may grant a use permit to allow greater height for second-story additions, up to 35 feet, measured in accordance with Subsection 20.24.080, and based on at least one of the following findings: a. The existing house has a partial ground story that causes an increase in the overall height of the building, and there are sound design reasons for considering a roofline which exceeds 28 feet. b. The natural downward or upward topography of the site causes an increase in the overall height of the building. The minimum roof pitch has been maintained on the addition to be consistent with the existing architectural design of the house. The height has been measured from the natural or finished grade to the highest point of the roof. c. The existing architectural character and design of the house is maintained. Design factors have been considered to offset or minimize the increased height, such as breakup in the mass and bulk, offsetting one or more portions of the addition from the ground-story wall line, and adding architectural details and elements such as horizontal trim or other features to create interest. | |||
13. Height limits in RHD District are specified for single-family residences only. The maximum building height for a single-family residence on a downhill site shall be 35 feet above the original grade of a site measured from the midpoint of the building envelope. The maximum permitted height for a single-family residence on an uphill site shall be 28 feet above the original grade of a site measured from the midpoint of the building envelope. | |||
14. Maximum building height is three stories and 35 feet, above natural or finished grade, whichever is lower, except within the San Pablo Avenue Specific Plan planning area on through-lots extending to San Pablo Avenue, maximum building height is 50 feet and five stories, as an incentive for lot consolidation. The maximum height allowed at the front setback line shall be 28 feet plus a forty-five-degree daylight plane. (See Subsection 20.24.070.B.), except within the San Pablo Avenue Specific Plan planning area on through-lots extending to San Pablo Avenue, where stepbacks are required pursuant to Subsection 20.24.070.C. | |||
15. Through lots are deemed to have two front property lines, one at each street, and front yard setback requirements shall be applicable to both lines. | |||
16. 10% of lot width, up to a maximum of five feet, with a minimum requirement of three feet, except that the minimum setback for multifamily structures in the R-3 District is five feet. | |||
17. 10% of lot width, or five feet, whichever is greater. | |||
18. One foot shall be added for each 12 feet of height above the lowest 15 feet of building height. Except within the San Pablo Avenue Specific Plan planning area, where no additional setback shall apply. | |||
19. Exceptions to setback requirements may be made in the case of a second-story addition to a single-family dwelling, as follows: | |||
(a) Vertical extension of nonconforming walls. Existing nonconforming walls which encroach into required setback areas shall be allowed to extend in a vertical plane under or over an existing wall, subject to design review by the Planning and Zoning Commission and obtaining a use permit. | |||
(b) Horizontal extension of nonconforming walls. Existing nonconforming walls which encroach into the required front yard or side yard setback areas may be extended in a in a horizontal plane, subject to design review by the Planning and Zoning Commission and obtaining a use permit. Such extensions shall not further encroach on any required setback (i.e., a nonconforming wall which encroaches one foot into a required setback shall not be permitted to encroach two feet), nor shall any such extension create a new encroachment in another direction. Required conditional use permit and design review findings for the extension of a nonconforming front wall shall be made separately from findings required for extension of other nonconforming walls. | |||
20. Projects in the San Pablo Avenue Specific Plan planning area shall also meet relevant regulations in the SanPablo Avenue Design Guidelines and Objective Design Standards, and required community benefits (Subsection 20.24.190), which may be updated from time to time. | |||
21. The San Pablo Avenue Specific Plan Planning area has no maximum residential density standard. |
Table 2B. Site Regulations by District: Nonresidential (20.24.020) | |||||
|---|---|---|---|---|---|
Standard | Zoning District | ||||
SC | SPC(13) | CMX | WF(1) | PF(1) | |
Residential Density (dwelling units/acre where residential development is proposed) | Minimum 20 Maximum 63 | Minimum 30 Maximum N/A | N/A | N/A | N/A |
Maximum FAR (floor area/lot area ratio) | |||||
Mixed-use development (more than 1 use, including residential and commercial or other permitted nonresidential uses) | 1.25 | 4.0/4.5(11) | 0.5 | 0.5 | N/A |
Commercial portion of any development (not to be exceeded, regardless of mix with other uses, or any bonus increase in the total FAR of development) | 1.25 | 0.95 | 0.5 | 0.5 | N/A |
Multifamily dwelling, where it is the sole use of a site(12) | 1.25 | 4.0/4.5(11) | N/A | N/A | N/A |
Live/work space | N/A | 4.0/4.5(11) | (4) | N/A | N/A |
Minimum Lot Area per Dwelling Unit (square feet) | N/A | N/A | (2) | N/A | N/A |
Minimum Lot Size (square feet) | None | None | 5,000 | None | |
Minimum Lot Width (feet) | None | None | 50 | None | |
Maximum Lot Coverage (% of lot area) | 100% | 100% | 80% | ||
Maximum Building Height (feet) | 35 | 68/85(4, 11) | 45 | 40 | |
Minimum Yard Setbacks (feet) | |||||
Front, or exterior side | (6)(7) | (6)(7) | None | (5) | |
Side, interior | (8) | (8) | (9) | ||
Rear | (8)(10) | (8)(10) | (9) | ||
Maximum Fence Height | See Subsection 20.24.110 | ||||
Minimum Usable Open Space (multifamily dwellings) | See Subsection 20.24.090 | ||||
Notes, Table 2B: |
|---|
1. In the WF and PF Districts, and in cases of public/semipublic uses in all districts, site regulations not otherwise specified will be determined by the Planning and Zoning Commission on a use permit/design review basis. |
2. Live/work space will be included in the calculation of commercial floor area and will be subject to the maximum FAR standards for each district. District standards for minimum lot area per dwelling shall not apply to live/work units. See Table 1 for land use permitting procedures for live/work in individual districts. |
3. (Reserved) |
4. See Subsection 20.24.070C for upper story stepback requirements. No projections shall be allowed in the area between the stepback and rear property line. |
5. No enclosed structure shall be located within 100 feet of the shoreline, except as specified in the Waterfront Master Plan. Continuous public access to the water's edge shall be preserved and established consistent with The Bay Trail—Planning for a Recreational Ring Around the Bay (ABAG, July 1989). |
6. Through lots are deemed to have two front property lines, one at each street, and front yard setback requirements shall be applicable to both lines. |
7. None required along San Pablo Avenue. If front setback is provided, it shall not exceed a depth of four feet at street level. Where fronting a street immediately parallel to San Pablo Avenue: 15 feet, plus a daylight plane. (See Subsection 20.24.070.B.) Where a property in the SC District has an exterior lot line at a street that intersects with Solano Avenue, and any property located directly across such a street is in a residential district: 15 feet, plus a daylight plane. (See Subsection 20.24.070.B.) |
8. None, except where an interior side or rear yard of a nonresidential property abuts an R District: See Subsection 20.24.070.A. |
9. The minimum setbacks where a lot abuts an R District shall be 10 feet at either side or rear yards. |
10. May be waived by Planning and Zoning Commission, except where rear yard abuts an R District. |
11. Up to 4.5 FAR and 85 feet building height permitted in the northern node, as depicted in the San Pablo Avenue Specific Plan Zoning District & Overlays map (Figure 2-2), in exchange for providing San Pablo Avenue Specific Plan community benefits (Subsection 20.24.190). |
12. Permitted for projects in which 100% of the units are affordable up to 120% of Area Median Income, with the exception of building manager's unit. |
13. Projects in the San Pablo Avenue Specific Plan planning area shall also meet relevant regulations in the San Pablo Avenue Design Guidelines and Objective Design Standards, and required community benefits, pursuant to Subsection 20.24.190, which may be updated from time to time. |
Specific P District Regulations | ||||||||
|---|---|---|---|---|---|---|---|---|
Uses | Min. Lot Area | Max. Ht. | Min Lot Width | Max. Lot Coverage(1) | Minimum Yards (1) | |||
Front | Rear | Side, Corner | Side, Interior | |||||
See a above | 5,000 sq. ft. | Same as underlying district | 50 ft. | 70% | 15 ft. | 10 ft. (1) | 5 ft. (2) | 5 ft. |
Average slope shall be measured by utilizing the following formula: | |
S= | .00229 IL A |
S = Average cross slope of the ground in percent |
I = Contour interval in feet |
L = Combined length of all contours (in feet) |
A = Area of the parcel in acres |
Example: | |
|---|---|
13.74% = | .00229 x 2 x 3000 1.0 |
S = 14% (rounded) |
I = 2 feet (vertical interval between contour lines) |
L = 3000 feet (sum of measured horizontal length of contour lines) |
A = 1.0 acre (43,560 square feet) |
Table 3: Setback Areas, Encroachments (20.24.060) | ||||||
|---|---|---|---|---|---|---|
Type of Projection | Limitations | Maximum Projection into Required Setback Area | Minimum Distance from a Property Line for any Projection | |||
Required Front Yard | Required Rear Yard | Required Interior Side Yard | Required Exterior Side Yard | |||
Chimneys | 3 feet (any required setback) | 3 ft. | 3 ft. | |||
Open Stairways or landings | May be covered but not enclosed by walls on more than two (2) sides | 2 ft. (side yard) 6 ft. (front or rear yard) Except, no maximum projection within San Pablo Avenue Specific Plan planning area | 3 ft. | 3 ft. | ||
Balconies, Porches and Decks | No projection permitted (side yard) 6 ft. (front or rear yard) | |||||
Cornices, Eaves and Permanent Decorative Ornaments | Minimum seven (7) feet above grade | 2 ft. 6 in. | 2 ft. 6 in. | |||
Canopies and Awnings | Minimum seven (7) feet above grade | 6 ft. | 6 ft. | 2 ft. 6 in. | 2 ft. 6 in. | |
Projecting Bays | Maximum width equal to 25 percent of the wall plane from which bay projects. | 2 ft. 6 in. (any required setback) | 3 ft. | 3 ft. | ||
Table 3.B Required Setback for Mechanical Equipment | ||||
|---|---|---|---|---|
Height of Equipment (as measured from grade) | Minimum Distance from a Property Line | |||
Front(1) | Rear | Interior Side | Exterior Side(1,2) | |
Up to 3 feet in height | 10 feet | 3 feet | ||
Up to 5 feet in height | Not permitted | Not permitted | ||
Greater than 5 feet in height (including rooftop equipment) | 5 feet | |||
Notes, Table 3B: | |
|---|---|
1. | Mechanical equipment located in a street-facing (i.e. front or exterior side) yard shall be screened in compliance with subsection 20.24.110. |
2. | Mechanical equipment located in the street side yard, shall be oriented perpendicular to the property line so that fan exhaust is not directed to the adjacent right-of-way. |
DEVELOPMENT REGULATIONS
Table 2A. Site Regulations by District: Residential (20.24.020) | |||||
|---|---|---|---|---|---|
Standard | Zoning District | ||||
R-1 | R-2 | R-3(20) | R-4(1) | RHD(2) | |
Maximum Density (dwelling units/acre) | 12 (3)(10) | 35 | 63(21) | 87 | 6 or 9(4) |
Maximum FAR (floor area/lot area ratio) | |||||
Single-family dwelling Multifamily dwelling | 0.55(5) | 0.55(5) | 0.55(5) 1.50/2.0(6)(7) | N/A | 0.50(8) |
Minimum Lot Size (square feet)(10) | |||||
Single-family 2-family Multiple-family Public/quasi-public | 3,750 N/A N/A 10,000 | 3,750 3,750 3,750 10,000 | 3,750 3,750 3,750 10,000 | 5,000(8) | |
Minimum Lot Width (feet) | |||||
Single-family 2-family Multiple-family Public/quasi-public | 35 N/A N/A 75 | 35 37.5 37.5 75 | 50 50 50 75 | 50(8) | |
Maximum Lot Coverage (% of lot area) | N/A | 50% | 50% | ||
Single-family 2-family Multiple-family Public/quasi-public | 50% N/A N/A(11) | 50% 50% 50%(11) | 50% 50% 70%(11) | 40%(8) | |
Maximum Building Height (feet) | |||||
Single-family 2-family Multiple-family Public/quasi-public | 28(12) N/A N/A 35 | 28(12) 35/28(14) 35/28(14) 35 | 35 35/28(14) 50/35/28(14) 35 | (13)(8) | |
Minimum Yard Setbacks (feet) | |||||
Single-, Two-, Multiple-family: | |||||
Front | 15(15) | 15(15) | 15(15) | 15(8)(15) | |
Side, interior | (16) | (16) | (16) | (17)(8) | |
Side, exterior | 7.5 | 7.5(18) | 7.5(18) | 17) (8) | |
Rear | 20 | 15 | 15 | 20(8) | |
Single-family second-story addition | (19) | (19) | (19) | ||
Public/quasi-public | (11) | (11) | (11) | ||
Maximum Fence Height | See Subsection 20.24.110 | ||||
Minimum Usable Open Space (multifamily dwellings) | See Subsection 20.24.090 | ||||
Accessory Buildings | See Subsection 20.24.130 | ||||
Notes, Table 2A: | |||
|---|---|---|---|
1. In R-4 District, site regulations not specified will be determined by the Planning and Zoning Commission on consideration of an application for a use permit. Existing densities of developed sites are deemed to be conforming, but existing densities will not be permitted to be increased above the maximum density permitted in the R-3 District. | |||
2. In the RHD District, all multiple-family development, and any single-family development which comprises two or more acres of land area, shall be processed as a development plan under planned unit development procedures specified in Subsection 20.100.060. See Subsection 20.24.040 for development regulations applicable to the RHD District in addition to the regulations stated in this table. | |||
3. The higher maximum density stated in the General Plan takes into account the pre-existence of substandard nonconforming lots. | |||
4. The Albany General Plan divides the area subject to the RHD District into two density classifications: Low density = 6 dwelling units/acre. High density = 9 dwelling units/acre. Through the planned unit development process (Subsection 20.100.060), allowable density may be reduced according to slope density restrictions and/or the presence of natural topographic features. The City may permit the transfer of density from one portion of a development site to another, upon making a finding that the density transfer is necessary to accomplish the purposes of this chapter. | |||
5. The Planning and Zoning Commission may approve a floor/area ratio of up to 0.60 based on determination that any of the following conditions exist: (a) The site is of such a size that application of the 0.55 floor/area ratio would result in a gross square footage of less than 1,500 square feet. (b) The site is in a zone other than R-1 and buildings on any surrounding properties exceed FAR 0.60, and the higher FAR is warranted by considerations of harmonious transition among properties. (c) The proposed design has architectural features that contribute substantially to neighborhood quality, which could not be achieved in a smaller building mass. | |||
6. FAR may be increased to 1.75 where open space is provided at twice the minimum requirement stated in Subsection 20.24.090.B. As an incentive for lot consolidation, FAR may be increased to 2.0 within the San Pablo Avenue Specific Plan planning area on through-lots extending to San Pablo Avenue. | |||
7. Enclosed off-street parking shall be included in the calculation of the FAR, except that such parking area that is located entirely below grade may be excluded. (See Subsection 20.24.050.C.) | |||
8. Applies to single-family development in RHD District on land comprising less than two acres. Also shall be considered to be the minimum standards required for development of a single-family planned unit development on two acres or more, except that modified development standards may be approved if deemed appropriate by the Planning and Zoning Commission and City Council. | |||
9. (Reserved) | |||
10. Existing lots which do not meet minimum area standards may be developed or improved as provided in § 20.44, Nonconforming Uses, Structures and Lots. | |||
11. For public and quasi-public uses, lot coverage and yard setbacks will be determined by the Planning and Zoning Commission on consideration of an application for a use permit or design review. | |||
12. Planning and Zoning Commission, subject to design review criteria, may grant a use permit to allow greater height for second-story additions, up to 35 feet, measured in accordance with Subsection 20.24.080, and based on at least one of the following findings: a. The existing house has a partial ground story that causes an increase in the overall height of the building, and there are sound design reasons for considering a roofline which exceeds 28 feet. b. The natural downward or upward topography of the site causes an increase in the overall height of the building. The minimum roof pitch has been maintained on the addition to be consistent with the existing architectural design of the house. The height has been measured from the natural or finished grade to the highest point of the roof. c. The existing architectural character and design of the house is maintained. Design factors have been considered to offset or minimize the increased height, such as breakup in the mass and bulk, offsetting one or more portions of the addition from the ground-story wall line, and adding architectural details and elements such as horizontal trim or other features to create interest. | |||
13. Height limits in RHD District are specified for single-family residences only. The maximum building height for a single-family residence on a downhill site shall be 35 feet above the original grade of a site measured from the midpoint of the building envelope. The maximum permitted height for a single-family residence on an uphill site shall be 28 feet above the original grade of a site measured from the midpoint of the building envelope. | |||
14. Maximum building height is three stories and 35 feet, above natural or finished grade, whichever is lower, except within the San Pablo Avenue Specific Plan planning area on through-lots extending to San Pablo Avenue, maximum building height is 50 feet and five stories, as an incentive for lot consolidation. The maximum height allowed at the front setback line shall be 28 feet plus a forty-five-degree daylight plane. (See Subsection 20.24.070.B.), except within the San Pablo Avenue Specific Plan planning area on through-lots extending to San Pablo Avenue, where stepbacks are required pursuant to Subsection 20.24.070.C. | |||
15. Through lots are deemed to have two front property lines, one at each street, and front yard setback requirements shall be applicable to both lines. | |||
16. 10% of lot width, up to a maximum of five feet, with a minimum requirement of three feet, except that the minimum setback for multifamily structures in the R-3 District is five feet. | |||
17. 10% of lot width, or five feet, whichever is greater. | |||
18. One foot shall be added for each 12 feet of height above the lowest 15 feet of building height. Except within the San Pablo Avenue Specific Plan planning area, where no additional setback shall apply. | |||
19. Exceptions to setback requirements may be made in the case of a second-story addition to a single-family dwelling, as follows: | |||
(a) Vertical extension of nonconforming walls. Existing nonconforming walls which encroach into required setback areas shall be allowed to extend in a vertical plane under or over an existing wall, subject to design review by the Planning and Zoning Commission and obtaining a use permit. | |||
(b) Horizontal extension of nonconforming walls. Existing nonconforming walls which encroach into the required front yard or side yard setback areas may be extended in a in a horizontal plane, subject to design review by the Planning and Zoning Commission and obtaining a use permit. Such extensions shall not further encroach on any required setback (i.e., a nonconforming wall which encroaches one foot into a required setback shall not be permitted to encroach two feet), nor shall any such extension create a new encroachment in another direction. Required conditional use permit and design review findings for the extension of a nonconforming front wall shall be made separately from findings required for extension of other nonconforming walls. | |||
20. Projects in the San Pablo Avenue Specific Plan planning area shall also meet relevant regulations in the SanPablo Avenue Design Guidelines and Objective Design Standards, and required community benefits (Subsection 20.24.190), which may be updated from time to time. | |||
21. The San Pablo Avenue Specific Plan Planning area has no maximum residential density standard. |
Table 2B. Site Regulations by District: Nonresidential (20.24.020) | |||||
|---|---|---|---|---|---|
Standard | Zoning District | ||||
SC | SPC(13) | CMX | WF(1) | PF(1) | |
Residential Density (dwelling units/acre where residential development is proposed) | Minimum 20 Maximum 63 | Minimum 30 Maximum N/A | N/A | N/A | N/A |
Maximum FAR (floor area/lot area ratio) | |||||
Mixed-use development (more than 1 use, including residential and commercial or other permitted nonresidential uses) | 1.25 | 4.0/4.5(11) | 0.5 | 0.5 | N/A |
Commercial portion of any development (not to be exceeded, regardless of mix with other uses, or any bonus increase in the total FAR of development) | 1.25 | 0.95 | 0.5 | 0.5 | N/A |
Multifamily dwelling, where it is the sole use of a site(12) | 1.25 | 4.0/4.5(11) | N/A | N/A | N/A |
Live/work space | N/A | 4.0/4.5(11) | (4) | N/A | N/A |
Minimum Lot Area per Dwelling Unit (square feet) | N/A | N/A | (2) | N/A | N/A |
Minimum Lot Size (square feet) | None | None | 5,000 | None | |
Minimum Lot Width (feet) | None | None | 50 | None | |
Maximum Lot Coverage (% of lot area) | 100% | 100% | 80% | ||
Maximum Building Height (feet) | 35 | 68/85(4, 11) | 45 | 40 | |
Minimum Yard Setbacks (feet) | |||||
Front, or exterior side | (6)(7) | (6)(7) | None | (5) | |
Side, interior | (8) | (8) | (9) | ||
Rear | (8)(10) | (8)(10) | (9) | ||
Maximum Fence Height | See Subsection 20.24.110 | ||||
Minimum Usable Open Space (multifamily dwellings) | See Subsection 20.24.090 | ||||
Notes, Table 2B: |
|---|
1. In the WF and PF Districts, and in cases of public/semipublic uses in all districts, site regulations not otherwise specified will be determined by the Planning and Zoning Commission on a use permit/design review basis. |
2. Live/work space will be included in the calculation of commercial floor area and will be subject to the maximum FAR standards for each district. District standards for minimum lot area per dwelling shall not apply to live/work units. See Table 1 for land use permitting procedures for live/work in individual districts. |
3. (Reserved) |
4. See Subsection 20.24.070C for upper story stepback requirements. No projections shall be allowed in the area between the stepback and rear property line. |
5. No enclosed structure shall be located within 100 feet of the shoreline, except as specified in the Waterfront Master Plan. Continuous public access to the water's edge shall be preserved and established consistent with The Bay Trail—Planning for a Recreational Ring Around the Bay (ABAG, July 1989). |
6. Through lots are deemed to have two front property lines, one at each street, and front yard setback requirements shall be applicable to both lines. |
7. None required along San Pablo Avenue. If front setback is provided, it shall not exceed a depth of four feet at street level. Where fronting a street immediately parallel to San Pablo Avenue: 15 feet, plus a daylight plane. (See Subsection 20.24.070.B.) Where a property in the SC District has an exterior lot line at a street that intersects with Solano Avenue, and any property located directly across such a street is in a residential district: 15 feet, plus a daylight plane. (See Subsection 20.24.070.B.) |
8. None, except where an interior side or rear yard of a nonresidential property abuts an R District: See Subsection 20.24.070.A. |
9. The minimum setbacks where a lot abuts an R District shall be 10 feet at either side or rear yards. |
10. May be waived by Planning and Zoning Commission, except where rear yard abuts an R District. |
11. Up to 4.5 FAR and 85 feet building height permitted in the northern node, as depicted in the San Pablo Avenue Specific Plan Zoning District & Overlays map (Figure 2-2), in exchange for providing San Pablo Avenue Specific Plan community benefits (Subsection 20.24.190). |
12. Permitted for projects in which 100% of the units are affordable up to 120% of Area Median Income, with the exception of building manager's unit. |
13. Projects in the San Pablo Avenue Specific Plan planning area shall also meet relevant regulations in the San Pablo Avenue Design Guidelines and Objective Design Standards, and required community benefits, pursuant to Subsection 20.24.190, which may be updated from time to time. |
Specific P District Regulations | ||||||||
|---|---|---|---|---|---|---|---|---|
Uses | Min. Lot Area | Max. Ht. | Min Lot Width | Max. Lot Coverage(1) | Minimum Yards (1) | |||
Front | Rear | Side, Corner | Side, Interior | |||||
See a above | 5,000 sq. ft. | Same as underlying district | 50 ft. | 70% | 15 ft. | 10 ft. (1) | 5 ft. (2) | 5 ft. |
Average slope shall be measured by utilizing the following formula: | |
S= | .00229 IL A |
S = Average cross slope of the ground in percent |
I = Contour interval in feet |
L = Combined length of all contours (in feet) |
A = Area of the parcel in acres |
Example: | |
|---|---|
13.74% = | .00229 x 2 x 3000 1.0 |
S = 14% (rounded) |
I = 2 feet (vertical interval between contour lines) |
L = 3000 feet (sum of measured horizontal length of contour lines) |
A = 1.0 acre (43,560 square feet) |
Table 3: Setback Areas, Encroachments (20.24.060) | ||||||
|---|---|---|---|---|---|---|
Type of Projection | Limitations | Maximum Projection into Required Setback Area | Minimum Distance from a Property Line for any Projection | |||
Required Front Yard | Required Rear Yard | Required Interior Side Yard | Required Exterior Side Yard | |||
Chimneys | 3 feet (any required setback) | 3 ft. | 3 ft. | |||
Open Stairways or landings | May be covered but not enclosed by walls on more than two (2) sides | 2 ft. (side yard) 6 ft. (front or rear yard) Except, no maximum projection within San Pablo Avenue Specific Plan planning area | 3 ft. | 3 ft. | ||
Balconies, Porches and Decks | No projection permitted (side yard) 6 ft. (front or rear yard) | |||||
Cornices, Eaves and Permanent Decorative Ornaments | Minimum seven (7) feet above grade | 2 ft. 6 in. | 2 ft. 6 in. | |||
Canopies and Awnings | Minimum seven (7) feet above grade | 6 ft. | 6 ft. | 2 ft. 6 in. | 2 ft. 6 in. | |
Projecting Bays | Maximum width equal to 25 percent of the wall plane from which bay projects. | 2 ft. 6 in. (any required setback) | 3 ft. | 3 ft. | ||
Table 3.B Required Setback for Mechanical Equipment | ||||
|---|---|---|---|---|
Height of Equipment (as measured from grade) | Minimum Distance from a Property Line | |||
Front(1) | Rear | Interior Side | Exterior Side(1,2) | |
Up to 3 feet in height | 10 feet | 3 feet | ||
Up to 5 feet in height | Not permitted | Not permitted | ||
Greater than 5 feet in height (including rooftop equipment) | 5 feet | |||
Notes, Table 3B: | |
|---|---|
1. | Mechanical equipment located in a street-facing (i.e. front or exterior side) yard shall be screened in compliance with subsection 20.24.110. |
2. | Mechanical equipment located in the street side yard, shall be oriented perpendicular to the property line so that fan exhaust is not directed to the adjacent right-of-way. |