12 DIMENSIONAL STANDARDS
Table 18.12.020-2 Standard Lot Dimensional Standards for Residential Zone Districts [Numbers in brackets indicate additional requirements listed at the end of the table] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
ZONING DISTRICT DIMENSIONAL STANDARD | R-0.4 | R-1 | R-2 | R-2.9 | R-3.5 | R-4.3 | R-5 | R-6 | R-8 | R-14 |
MINIMUM LOT AREA Note: Additional regulations on lot dimensions may apply pursuant to: (a) BIMC § 17.12.030.A, flexible lot subdivision open space development option, or (b) BIMC § 17.12.030.B, flexible lot subdivision cluster development option. | ||||||||||
Standard Lots | 100,000 sq. ft. | 40,000 sq. ft. | 20,000 sq. ft. | 15,000 sq. ft. | 12,500 sq. ft. | 10,000 sq. ft. | 8,500 sq. ft. | 7,260 sq. ft. | 5,400 sq. ft. | 3,100 sq. ft. |
MAXIMUM DENSITY (Minimum lot area per dwelling unit) Note: Additional regulations on density may apply pursuant to: (a) BIMC § 16.20.160.F.5.a, Additional Development Standards for Regulated Uses, Land Divisions and Land Use Permits, Density Calculation. | ||||||||||
Standard Lots | ||||||||||
Base Density | 100,000 sq. ft. | 40,000 sq. ft. | 20,000 sq. ft.[1] | 15,000 sq. ft.[2] | 12,500 sq. ft.[2] | 10,000 sq. ft.[2] | 8,500 sq. ft. | 7,260 sq. ft. | 5,400 sq. ft. | 3,100 sq. ft. |
Bonus Density pursuant to BIMC § 18.12.030.A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | 3,630 sq. ft. | 2,074 sq. ft. |
MINIMUM LOT DIMENSIONS Note: Additional regulations on lot dimensions may apply pursuant to: (a) BIMC § 17.12.030.A, flexible lot subdivision open space development option, or (b) BIMC § 17.12.030.B, flexible lot subdivision cluster development option. | ||||||||||
Standard Lots | ||||||||||
Depth | 110 ft. | 80 ft. | 80 ft. | N/A | N/A | N/A | N/A | 60 ft. | 60 ft. | 60 ft. |
Width | 110 ft. | 80 ft. | 80 ft. [70 ft. for lots that abut the shoreline] | N/A | N/A | N/A | N/A | 60 ft. | 60 ft. | 60 ft. |
MAXIMUM LOT COVERAGE | ||||||||||
Standard Lots | ||||||||||
Base | 10% | 15% | 20% | 25% | 25% | 25% | 25% | N/A | 25% | 40% |
Bonus | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | 40% Pursuant to BIMC § 18.12.030.A | 50% Pursuant to BIMC § 18.12.030.B |
MINIMUM SETBACKS Note: Landscaped areas may serve as setbacks (i.e., setbacks are not in addition to landscaped areas), and some encroachments into setback areas are permitted pursuant to BIMC § 18.12.040. Note: Additional setbacks may be required by: (a) Chapter 16.08 or 16.12 BIMC, or (b) Chapter 16.20 BIMC, Critical Areas, or (c) BIMC § 16.28.040, mining regulations, or (d) BIMC § 18.09.030, Use Specific Standards, or (e) BIMC § 16.12.030.B.3.i, Regulations – Shoreline Structure Setback View Requirement, or (f) BIMC § 18.15.010, Landscaping and Screening. | ||||||||||
Standard Lots | ||||||||||
Front/Street | ||||||||||
2 stories or less | 25 ft. | 25 ft. | 5 ft. from edge of paved portion of Point Monroe Dr. | 25 ft. | ||||||
More than 2 stories | Add 4 feet for each story over 2 stories [3] | Same as for R-0.4 through R-5 | ||||||||
Side (not adjacent to street) | ||||||||||
2 stories or less | 15 ft. each side | 10 ft. min., 25 ft. total | 5 ft. min., 15 ft. total | 5 ft. min., 15 ft. total | 5 ft. min., 10 ft. total | 5 ft. min., 15 ft. total | ||||
More than 2 stories | Add 5 ft. on each side, and 10 ft. to the total setback required, for each story over 2. If there is only one side yard, it is increased by 5 ft. for each story over 2 [3] | Same as for R-0.4 through R-5 | ||||||||
Rear (not adjacent to street) | ||||||||||
2 stories or less | 25 ft. | 15 ft. | 15 ft. | 15 ft. | 15 ft. | |||||
More than 2 stories | Add 4 feet for each story over 2 [3] | Same as for R-0.4 through R-5 | ||||||||
Shoreline Jurisdiction | See Table 16.12.030-2, Dimensional Standards Table, and BIMC § 16.12.030.B.3.i, Regulations – Shoreline Structure Setback View Requirement. | |||||||||
MAXIMUM BUILDING AND STRUCTURE HEIGHT [4] Note: Bonus may not be available in the shoreline jurisdiction | ||||||||||
All lots | ||||||||||
Base | 30 ft. | 30 ft. | 25 ft. | 30 ft. | 35 | |||||
Bonus for Nonresidential Uses If Conditional Use Permit Conditions Met | 35 ft. | 35 ft. | 30 ft. | 35 ft. | 40 ft. | 40 ft. See BIMC § 18.12.030.B | ||||
Distribution Utility Poles | 55 ft. in height above grade. Alternative height limits may apply if additional conditional use permit provisions of BIMC § 2.16.050.F are met. See BIMC § 18.09.030.F.2 for use standards. | |||||||||
Transmission Utility Poles | Up to a 25 percent increase above existing pole height above grade with a maximum height of 100 ft. Alternative height limits may apply if additional conditional use permit provisions of BIMC § 2.16.050.F are met. See BIMC § 18.09.030.F.2 for use standards. | |||||||||
Exemption | Alternative height limits may apply for nonresidential uses if additional conditional use permit provisions of BIMC Title 2 are met. Some encroachments through height limits are permitted under BIMC § 18.12.040. | |||||||||
Shoreline Jurisdiction | See Table 16.12.030-2, Dimensional Standards Table, and BIMC § 16.12.030.B.3.i, Regulations – Shoreline Structure Setback View Requirement. | |||||||||
[1] | The base density for that parcel in the Lynwood Center special planning area designated as R-2 is one unit per 20,000 sq. ft., but may be increased up to 3 units per acre; provided, that a public access easement is granted for that portion of the parcel that lies to the south of Point White Drive along the waters of Rich Passage. The base density of some parcels in the Fort Ward historic overlay district may be increased as shown in BIMC § 18.24.110. |
[2] | Pursuant to Chapters 18.18 and 18.27 BIMC the minimum lot area for a dwelling unit shall be 5,400 square feet for that area designated on the official land use map as the urban single-family overlay district (R-8SF). All other requirements of this chapter shall apply. |
[3] | Additional setbacks for taller buildings must be from the ground upward – i.e., this is not a “step-back” requirement for upper floors. |
[4] | For community and educational facilities (as listed in Table 18.09.020), spires, towers and other vertical features with horizontal cross-sections no more than five percent of the footprint of the primary structure may have a maximum height of 10 feet above the maximum base height, and shall be reviewed through a conditional use permit. |
Table 18.12.020-2 Standard Lot Dimensional Standards for Residential Zone Districts [Numbers in brackets indicate additional requirements listed at the end of the table] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
ZONING DISTRICT DIMENSIONAL STANDARD | R-0.4 | R-1 | R-2 | R-2.9 | R-3.5 | R-4.3 | R-5 | R-6 | R-8 | R-14 |
MINIMUM LOT AREA Note: Additional regulations on lot dimensions may apply pursuant to: (a) BIMC § 17.12.030.A, flexible lot subdivision open space development option, or (b) BIMC § 17.12.030.B, flexible lot subdivision cluster development option. | ||||||||||
Standard Lots | 100,000 sq. ft. | 40,000 sq. ft. | 20,000 sq. ft. | 15,000 sq. ft. | 12,500 sq. ft. | 10,000 sq. ft. | 8,500 sq. ft. | 7,260 sq. ft. | 5,400 sq. ft. | 3,100 sq. ft. |
MAXIMUM DENSITY (Minimum lot area per dwelling unit) Note: Additional regulations on density may apply pursuant to: (a) BIMC § 16.20.160.F.5.a, Additional Development Standards for Regulated Uses, Land Divisions and Land Use Permits, Density Calculation. | ||||||||||
Standard Lots | ||||||||||
Base Density | 100,000 sq. ft. | 40,000 sq. ft. | 20,000 sq. ft.[1] | 15,000 sq. ft.[2] | 12,500 sq. ft.[2] | 10,000 sq. ft.[2] | 8,500 sq. ft. | 7,260 sq. ft. | 5,400 sq. ft. | 3,100 sq. ft. |
Bonus Density pursuant to BIMC § 18.12.030.A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | 3,630 sq. ft. | 2,074 sq. ft. |
MINIMUM LOT DIMENSIONS Note: Additional regulations on lot dimensions may apply pursuant to: (a) BIMC § 17.12.030.A, flexible lot subdivision open space development option, or (b) BIMC § 17.12.030.B, flexible lot subdivision cluster development option. | ||||||||||
Standard Lots | ||||||||||
Depth | 110 ft. | 80 ft. | 80 ft. | N/A | N/A | N/A | N/A | 60 ft. | 60 ft. | 60 ft. |
Width | 110 ft. | 80 ft. | 80 ft. [70 ft. for lots that abut the shoreline] | N/A | N/A | N/A | N/A | 60 ft. | 60 ft. | 60 ft. |
MAXIMUM LOT COVERAGE | ||||||||||
Standard Lots | ||||||||||
Base | 10% | 15% | 20% | 25% | 25% | 25% | 25% | N/A | 25% | 40% |
Bonus | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | 40% Pursuant to BIMC § 18.12.030.A | 50% Pursuant to BIMC § 18.12.030.B |
MINIMUM SETBACKS Note: Landscaped areas may serve as setbacks (i.e., setbacks are not in addition to landscaped areas), and some encroachments into setback areas are permitted pursuant to BIMC § 18.12.040. Note: Additional setbacks may be required by: (a) Chapter 16.08 or 16.12 BIMC, or (b) Chapter 16.20 BIMC, Critical Areas, or (c) BIMC § 16.28.040, mining regulations, or (d) BIMC § 18.09.030, Use Specific Standards, or (e) BIMC § 16.12.030.B.3.i, Regulations – Shoreline Structure Setback View Requirement, or (f) BIMC § 18.15.010, Landscaping and Screening. | ||||||||||
Standard Lots | ||||||||||
Front/Street | ||||||||||
2 stories or less | 25 ft. | 25 ft. | 5 ft. from edge of paved portion of Point Monroe Dr. | 25 ft. | ||||||
More than 2 stories | Add 4 feet for each story over 2 stories [3] | Same as for R-0.4 through R-5 | ||||||||
Side (not adjacent to street) | ||||||||||
2 stories or less | 15 ft. each side | 10 ft. min., 25 ft. total | 5 ft. min., 15 ft. total | 5 ft. min., 15 ft. total | 5 ft. min., 10 ft. total | 5 ft. min., 15 ft. total | ||||
More than 2 stories | Add 5 ft. on each side, and 10 ft. to the total setback required, for each story over 2. If there is only one side yard, it is increased by 5 ft. for each story over 2 [3] | Same as for R-0.4 through R-5 | ||||||||
Rear (not adjacent to street) | ||||||||||
2 stories or less | 25 ft. | 15 ft. | 15 ft. | 15 ft. | 15 ft. | |||||
More than 2 stories | Add 4 feet for each story over 2 [3] | Same as for R-0.4 through R-5 | ||||||||
Shoreline Jurisdiction | See Table 16.12.030-2, Dimensional Standards Table, and BIMC § 16.12.030.B.3.i, Regulations – Shoreline Structure Setback View Requirement. | |||||||||
MAXIMUM BUILDING AND STRUCTURE HEIGHT [4] Note: Bonus may not be available in the shoreline jurisdiction | ||||||||||
All lots | ||||||||||
Base | 30 ft. | 30 ft. | 25 ft. | 30 ft. | 35 | |||||
Bonus for Nonresidential Uses If Conditional Use Permit Conditions Met | 35 ft. | 35 ft. | 30 ft. | 35 ft. | 40 ft. | 40 ft. See BIMC § 18.12.030.B | ||||
Distribution Utility Poles | 55 ft. in height above grade. Alternative height limits may apply if additional conditional use permit provisions of BIMC § 2.16.050.F are met. See BIMC § 18.09.030.F.2 for use standards. | |||||||||
Transmission Utility Poles | Up to a 25 percent increase above existing pole height above grade with a maximum height of 100 ft. Alternative height limits may apply if additional conditional use permit provisions of BIMC § 2.16.050.F are met. See BIMC § 18.09.030.F.2 for use standards. | |||||||||
Exemption | Alternative height limits may apply for nonresidential uses if additional conditional use permit provisions of BIMC Title 2 are met. Some encroachments through height limits are permitted under BIMC § 18.12.040. | |||||||||
Shoreline Jurisdiction | See Table 16.12.030-2, Dimensional Standards Table, and BIMC § 16.12.030.B.3.i, Regulations – Shoreline Structure Setback View Requirement. | |||||||||
[1] | The base density for that parcel in the Lynwood Center special planning area designated as R-2 is one unit per 20,000 sq. ft., but may be increased up to 3 units per acre; provided, that a public access easement is granted for that portion of the parcel that lies to the south of Point White Drive along the waters of Rich Passage. The base density of some parcels in the Fort Ward historic overlay district may be increased as shown in BIMC § 18.24.110. |
[2] | Pursuant to Chapters 18.18 and 18.27 BIMC the minimum lot area for a dwelling unit shall be 5,400 square feet for that area designated on the official land use map as the urban single-family overlay district (R-8SF). All other requirements of this chapter shall apply. |
[3] | Additional setbacks for taller buildings must be from the ground upward – i.e., this is not a “step-back” requirement for upper floors. |
[4] | For community and educational facilities (as listed in Table 18.09.020), spires, towers and other vertical features with horizontal cross-sections no more than five percent of the footprint of the primary structure may have a maximum height of 10 feet above the maximum base height, and shall be reviewed through a conditional use permit. |
![]() |
Table 18.12.030: Optional Affordable Housing Bonus Summary Table | |||
|---|---|---|---|
Size of Development | Residential development less than 10,000 sq. ft. | Residential development of 10,000 sq. ft. but less than 60,000 sq. ft. | Residential development more than 60,000 sq. ft. |
Affordable Housing FAR Bonus | Must provide 100 percent of bonus square footage for extremely low, very low, or moderate income groups. | Must comply with following ratios: (a) 100 percent of bonus for all moderate; OR (b) 0.2 of bonus for extremely low, very low, or low income groups; 0.5 of bonus for moderate income group; and 0.3 of bonus for middle income group. | Must comply with following ratios: 0.1 of bonus for extremely low, very low or low income groups; 0.6 of bonus for moderate income group; and 0.3 of bonus for middle income group. |
Table 18.12.040: Permitted Setback/Height Modifications | ||
|---|---|---|
Type of Encroachment | Encroachment Permitted | Conditions |
Permitted Setback Modifications | ||
Fence or combined fence and berm up to 6 feet high | In any required setback subject to applicable regulations in BIMC Title 15 | Except as provided in BIMC § 18.12.040.B and Chapter 16.12 BIMC |
Nonscreening fences or combined nonscreening fence and berm up to 8 feet high | In any required setback subject to applicable regulations in BIMC Title 15 | Except as provided in Chapter 16.12 BIMC |
Chimneys, flues, awnings, bay windows, and greenhouse windows | Up to 18 inches into any required setback | |
Covered porches, bay windows and eaves within the Ericksen Avenue overlay district | Up to 5 feet into the front yard | Bay windows must be cantilevered outward from the wall, and may not result in any portion of the building floor area extending into the setback |
Any structures, including but not limited to uncovered steps, porches, and decks less than or equal to 30 inches in height | Up to 2 feet into front and side setbacks. Up to 5 feet into required rear setbacks. | |
Eaves | May extend up to 24 inches in any required setback except shoreline structure setback | |
At or near grade structures such as uncovered patios, sidewalks, and driveways | In any required setback | May not exceed 4 inches in height |
Signs | In any required setback | Must conform to Chapter 15.08 BIMC |
Overhead or underground primary utilities and accessory utilities when they are not the principal use of the site | In any required setback, perimeter or roadside buffer | Must conform to Chapters 16.12 and 16.20 BIMC. Does not apply to above ground utilities such as propane tanks. |
Composting bins | In side or rear setback areas | |
Bioretention/rain gardens | In any required setback | In accordance with Chapter 15.20 BIMC |
Rain barrels/cisterns | In any required setback | In accordance with Chapter 15.20 BIMC |
Wall-mounted on-demand hot water heaters | Up to 18 inches into side or rear setbacks | Permitted if buffered or enclosed to prevent noise impacts to neighboring properties |
Below-ground geothermal equipment | In any required setback, perimeter or roadside buffer | Must conform to Chapters 16.12 and 16.20 BIMC. Permitted if any excavated areas are promptly relandscaped after installation is complete. |
Rockeries and retaining walls less than 4 feet in height | In any required setback | Rockeries and retaining walls greater than 4 feet in height may be permitted with qualified geotechnical engineer determination, and city concurrence, that it is necessary for slope stabilization. |
Public communications tower | In any required setback subject to applicable regulations in BIMC Title 15 | Must conform to Chapters 16.12 and 16.20 BIMC |
Permitted Height Modifications | ||
Small wind energy generators | Up to 18 inches above the maximum building height in the district | |
Solar panels | Up to 18 inches above the maximum building height in the district | |
Noncommercial, nonparabolic antennas affixed to noncommercial communication towers | Up to 50 feet in height above grade | |
One flagpole per parcel | Up to 45 feet in height above grade | |
Public communications tower | Up to 120 feet in height above grade | A building permit is required for a public communications tower. A conditional use permit shall be required for a public communications tower to be constructed between 71 feet and 120 feet above grade. A public communications tower shall not exceed 120 feet in height. |
![]() |
![]() |