Zoneomics Logo
search icon

Blooming Grove City Zoning Code

ARTICLE 3

BASE DISTRICT REGULATION

§ 1 Specific Purpose.

This district is intended to be composed primarily of single-family dwellings (including duplexes).
(Ordinance 348 adopted 6/19/18)

§ 2 Use Regulations.

A. 
Area, Yard and Height Regulations.
“R” Area, Yard & Height Regulations
Lot Width (Min.)
60 feet
Lot Depth (Min.)
100 feet
Front Yard Setback (Min.)
15 feet
(25 feet for HUD-Code Manufactured Homes)
Side Yard Setback (Min.)
 
Interior Lot Lines
5 feet
(10 feet for HUD-Code Manufactured Homes)
Street Lot Lines
10 feet
Rear Yard Setback (Min.)
10 feet
Height (Max.)
30 feet
Lot Coverage (Max.)
50%
B. 
Height. The height of a permitted nonresidential structure shall not exceed forty (40) feet.
C. 
Minimum Dwelling Size. Minimum Dwelling Size shall be no less than 1,000 square feet of living area.
(Ordinance 348 adopted 6/19/18; Ordinance 369 adopted 8/1/2022; Ordinance 375 adopted 7/3/2023)

§ 3 Off-Street Parking Regulations.

A. 
Off-street parking shall be provided in accordance with Article 7, Division 105 Vehicle Parking Regulations.
B. 
No parking space shall occupy any part of the required front yard of a nonresidential use.
C. 
Vehicles may not be parked or stored on grass.
(Ordinance 348 adopted 6/19/18)

§ 1 Specific Purpose.

Apartments and other multifamily residential structures (not including duplexes) are permitted by special permit in residential and commercial zones.
(Ordinance 348 adopted 6/19/18)

§ 2 “MF” Density, Area, Yard, & Height Regulations.

“MF” Area, Yard, & Height Regulations
Setbacks (Min.)
 
From Internal Streets
30 feet from centerline
From Public Rights-of-Way
15 feet from right-of-way
From Facing Structures
30 feet
From Adjacent Structures
30 feet
Rear Yard Setback (Min.)
15 feet
Height (Max.)
40 feet
Unit Area (Min.)
250 sq. ft. living area
(Ordinance 348 adopted 6/19/18)

§ 3 Off-Street Parking Regulations.

A. 
Off-street parking shall be provided in accordance with Article 7 Division 105 Vehicle Parking Regulations.
B. 
Parking must be located on the opposite side of the apartment building from the street.
(Ordinance 348 adopted 6/19/18)

§ 1 Purpose.

This district is intended to accommodate all types and sizes of commercial enterprises.
(Ordinance 348 adopted 6/19/18)

§ 2 Use Regulations.

Land and structures in this zoning district shall be used according to the regulations for this district as listed in Article 2 - Permitted Uses.
(Ordinance 348 adopted 6/19/18)

§ 3 Height Regulations.

There shall be a maximum height of forty (40) feet.
(Ordinance 348 adopted 6/19/18)

§ 4 Area Regulations.

A. 
There is no minimum lot area for nonresidential uses in this district.
B. 
There is no maximum building area devoted to any permissible use in this district.
(Ordinance 348 adopted 6/19/18)

§ 5 Yard Regulations.

A. 
The minimum yard abutting a public street shall be ten (10) feet.
B. 
There shall be no minimum interior side yard requirement.
C. 
On any lot in this district used for commercial purposes which adjoins any residential district, the minimum building line setback adjacent to such residential district, shall be twenty (20') feet. Within that 20' setback, a ten (10') foot wide landscaped buffer yard with no paving, dumpsters or other improvements shall be provided and the screening requirement of Article 5, Division 80 Screening Devices shall be complied with.
D. 
When a multi-story commercial structure is erected upon a lot in this district which adjoins any residential district, the minimum yard adjacent to such residential district shall be increased five (5) feet for each story more than one.
(Ordinance 348 adopted 6/19/18)

§ 6 Off-Street Parking Regulations.

A. 
For each permissible use in this district, off-street parking shall be provided in accordance with Article 7 Division 105 Vehicle Parking Regulations.
B. 
A maximum of forty percent (40%) of the curbline and parkway adjacent to property in this district shall be used for vehicular access to such property.
(Ordinance 348 adopted 6/19/18)

§ 7 Special Conditions.

Outside sales and storage shall not be allowed within fifty feet (50') of any residentially zoned property. No sale or storage of materials shall be allowed within any designated emergency access easement or fire lane.
(Ordinance 348 adopted 6/19/18)

§ 1 Purpose.

This district is intended to accommodate all types of industrial uses and all other uses not prohibited by ordinance.
(Ordinance 348 adopted 6/19/18)

§ 2 Use Regulations.

Land and structures in this zoning district shall be used according to the regulations for this district as listed in Article 2 - Permitted Uses.
(Ordinance 348 adopted 6/19/18)

§ 3 Height Regulations.

There shall be a maximum height of fifty (50) feet.
(Ordinance 348 adopted 6/19/18)

§ 4 Yard Regulations.

A. 
The minimum yard abutting a public street shall be ten (10) feet from the property line.
B. 
There shall be no minimum interior side yard in this district.
C. 
On any lot in this district used for industrial purposes which adjoins any residential district, the minimum building line setback adjacent to such residential district shall be twenty feet (20'). Within that 20' setback, a ten foot (10') wide landscaped buffer yard with no paving, dumpsters or other improvements shall be provided and the screening requirement of Article 5, Division 80 Screening Devices shall be complied with. For multi-story industrial buildings or structures, the building line setback adjacent to residential property shall be increased five (5) feet for each story more than one.
D. 
There shall be no minimum rear yard in this District.
(Ordinance 348 adopted 6/19/18)