Specific Criteria
Zones | ||
|---|---|---|
AC, RA | RS-1, RS-2, RS-3 | |
Density by group | ||
Group 1 | 12 per acre 50 max. | 10 per acre 30 max. |
Group 2 | 3 per acre 20 max. | 3 per acre 12 max. |
Group 3 | 1 per acre 10 max. | 1 per 2 acres 8 max. |
Housing structure setbacks1 | ||
Group 1, up to 4 animals | 25 feet | 25 feet |
Group 1, over 4 animals | 50 feet | 50 feet |
Group 2, up to 2 animals | 25 feet | 25 feet |
Group 2, over 2 animals | 50 feet | 50 feet |
Group 3, up to 2 animals | 50 feet | 50 feet |
Group 3, over 3 animals | 75 feet | 75 feet |
NOTES: | |
|---|---|
1 | Setbacks from all property lines. Should one structure be used to house a combination of animal types, the most restrictive setback shall apply. |
Quarry-Related Feature | Existing Residential Use (feet) | Existing Nonresidential Building (feet) | Adjoining Road (feet) | Public/Nonprofit Park (feet) | Cemetery or Stream Bank (feet) | Adjoining Property (feet) |
|---|---|---|---|---|---|---|
Stockpiles or spoil piles (from toe of slope) | 300 | 300 | 200 | 300 | 100 | 300 |
Mineral processing equipment (e.g., rushers, sorters, conveyors, dryers, etc.) | 500 | 300 | 200 | 300 | 100 | 300 |
Quarry pit (top of natural slope of any excavation) | 500 | 300 | 200 | 300 | 300 | 300 |
On-site access roads and off-street parking, loading and vehicle storage and weighing and washing facilities | 300 | 300 | 200 | 300 | 300 | 300 |
Other operational equipment, structures and/or improvements | 500 | 300 | 300 | 300 | 100 | 100 |
Shopping Center Design Requirements | |||||||
|---|---|---|---|---|---|---|---|
Required Minimum Yard Setbacks | |||||||
Use | Minimum Required Lot Width (feet) | Minimum Required Lot Depth (feet) | Front, as Measured from Street ROW | One Side** | Both Sides** | Rear | Minimum Required Setback from Either Residential Zone or Use as Specified Below* |
Shopping center, as defined herein, with up to 50,000 square feet of gross floor area | 250, at the building setback line | 250 | 35 feet for buildings and structures (except permitted signs); 20 feet for off-street parking; off-street loading or dumpsters are required to be placed between the rear wall of the building and the rear property line. (The rear wall shall be the wall closest to the rear property line.) | 50 feet for buildings and structures (except permitted signs); 15 feet for off-street parking and loading spaces and dumpsters | 50 feet for buildings and structures (except permitted signs); 30 feet for off-street parking and loading spaces and dumpsters | 25 feet for all buildings, structures, off-street parking and loading spaces and dumpsters | 50 feet for buildings, structures, off-street parking and loading spaces and dumpsters for both residential zone and a residential use outside of a residential zone |
Shopping center, as defined herein, with between 50,000 and 100,000 square feet of gross floor area | 300, at the building setback line | 500 | 50 feet for buildings and structures (except permitted signs); 25 feet for off-street parking; off-street loading or dumpsters are required to be placed between the rear wall of the building and the rear property line. (The rear wall shall be the wall closest to the rear property line.) | 60 feet for buildings and structures (except permitted signs); 20 feet for off-street parking and loading spaces and dumpsters | 60 feet for buildings and structures (except permitted signs); 40 feet for off-street parking and loading spaces and dumpsters | 30 feet for all buildings, structures, off-street parking and loading spaces and dumpsters | 100 feet for buildings, structures, off-street parking and loading spaces and dumpsters for residential zone, and 50 feet for buildings structures, off-street parking, loading spaces and dumpsters for a residential use outside of a residential zone |
Shopping center, as defined herein, over 100,000 square feet of gross floor area | 500, at the building setback line | 750 | 100 feet for buildings and structures (except permitted signs); 40 feet for off-street parking; off-street loading nor dumpsters are required to be placed between the rear wall of the building and the rear property line. (The rear wall shall be the wall closest to the rear property line.) | 100 feet for buildings and structures (except permitted signs); 25 feet for off-street parking and loading spaces and dumpsters | 100 feet for buildings and structures (except permitted signs); 50 feet for off-street parking and loading spaces and dumpsters | 40 feet for all buildings, structures, off street parking and loading spaces and dumpsters | 200 feet for buildings, structures, off-street parking and loading spaces and dumpsters for residential zone; 50 feet for buildings structures, off-street parking, loading spaces and dumpsters for residential use outside of a residential zone |
Shopping Center Design Requirements | |||||||
|---|---|---|---|---|---|---|---|
Required Minimum Yard Setbacks | |||||||
Use | Minimum Required Lot Width (feet) | Minimum Required Lot Depth (feet) | Front, as Measured from Street ROW | One Side** | Both Sides** | Rear | Minimum Required Setback from Either Residential Zone or Use as Specified Below* |
Shopping center, as defined herein, with up to 50,000 square feet of gross floor area | 250, at the building setback line | 250 | 35 feet for buildings and structures (except permitted signs); 20 feet for off-street parking; off-street loading or dumpsters are required to be placed between the rear wall of the building and the rear property line. (The rear wall shall be the wall closest to the rear property line.) | 50 feet for buildings and structures (except permitted signs); 15 feet for off-street parking and loading spaces and dumpsters | 50 feet for buildings and structures (except permitted signs); 30 feet for off-street parking and loading spaces and dumpsters | 25 feet for all buildings, structures, off-street parking and loading spaces and dumpsters | 50 feet for buildings, structures, off-street parking and loading spaces and dumpsters for both residential zone and a residential use outside of a residential zone |
Shopping center, as defined herein, with between 50,000 and 100,000 square feet of gross floor area | 300, at the building setback line | 500 | 50 feet for buildings and structures (except permitted signs); 25 feet for off-street parking; off-street loading or dumpsters are required to be placed between the rear wall of the building and the rear property line. (The rear wall shall be the wall closest to the rear property line.) | 60 feet for buildings and structures (except permitted signs); 20 feet for off-street parking and loading spaces and dumpsters | 60 feet for buildings and structures (except permitted signs); 40 feet for off-street parking and loading spaces and dumpsters | 30 feet for all buildings, structures, off-street parking and loading spaces and dumpsters | 100 feet for buildings, structures, off-street parking and loading spaces and dumpsters for residential zone, and 50 feet for buildings structures, off-street parking, loading spaces and dumpsters for a residential use outside of a residential zone |
Shopping center, as defined herein, over 100,000 square feet of gross floor area | 500, at the building setback line | 750 | 100 feet for buildings and structures (except permitted signs); 40 feet for off-street parking; off-street loading nor dumpsters are required to be placed between the rear wall of the building and the rear property line. (The rear wall shall be the wall closest to the rear property line.) | 100 feet for buildings and structures (except permitted signs); 25 feet for off-street parking and loading spaces and dumpsters | 100 feet for buildings and structures (except permitted signs); 50 feet for off-street parking and loading spaces and dumpsters | 40 feet for all buildings, structures, off street parking and loading spaces and dumpsters | 200 feet for buildings, structures, off-street parking and loading spaces and dumpsters for residential zone; 50 feet for buildings structures, off-street parking, loading spaces and dumpsters for residential use outside of a residential zone |
Type of Use | Minimum | Maximum |
|---|---|---|
Single-family detached | 20%*** | 60% |
Accessory apartment | 0% | 10% |
Single-family semidetached and two-family | 0% | 25% |
Single-family attached (townhouse style) | 0% | 40% |
Multiple-family | 5% | 40%** |
Live-work units | 0% | 15% |
Neighborhood commercial center* | 25% | 60% |
Civic uses* | 5% | 25% |
NOTES: | |
|---|---|
(All percentages in this table are based on number of residential units/total number of residential units.) | |
* | Measured as a percentage of total gross lot area. |
** | If all multiple-family units are age restricted then multiple-family maximum may be raised to 60%. |
*** | Existing or approved single-family detached lots located within 1,000 feet of the neighborhood center may be counted toward satisfying this minimum, provided sidewalk connects said single-family detached lots directly to the neighborhood center. |
Specific Criteria
Zones | ||
|---|---|---|
AC, RA | RS-1, RS-2, RS-3 | |
Density by group | ||
Group 1 | 12 per acre 50 max. | 10 per acre 30 max. |
Group 2 | 3 per acre 20 max. | 3 per acre 12 max. |
Group 3 | 1 per acre 10 max. | 1 per 2 acres 8 max. |
Housing structure setbacks1 | ||
Group 1, up to 4 animals | 25 feet | 25 feet |
Group 1, over 4 animals | 50 feet | 50 feet |
Group 2, up to 2 animals | 25 feet | 25 feet |
Group 2, over 2 animals | 50 feet | 50 feet |
Group 3, up to 2 animals | 50 feet | 50 feet |
Group 3, over 3 animals | 75 feet | 75 feet |
NOTES: | |
|---|---|
1 | Setbacks from all property lines. Should one structure be used to house a combination of animal types, the most restrictive setback shall apply. |
Quarry-Related Feature | Existing Residential Use (feet) | Existing Nonresidential Building (feet) | Adjoining Road (feet) | Public/Nonprofit Park (feet) | Cemetery or Stream Bank (feet) | Adjoining Property (feet) |
|---|---|---|---|---|---|---|
Stockpiles or spoil piles (from toe of slope) | 300 | 300 | 200 | 300 | 100 | 300 |
Mineral processing equipment (e.g., rushers, sorters, conveyors, dryers, etc.) | 500 | 300 | 200 | 300 | 100 | 300 |
Quarry pit (top of natural slope of any excavation) | 500 | 300 | 200 | 300 | 300 | 300 |
On-site access roads and off-street parking, loading and vehicle storage and weighing and washing facilities | 300 | 300 | 200 | 300 | 300 | 300 |
Other operational equipment, structures and/or improvements | 500 | 300 | 300 | 300 | 100 | 100 |
Shopping Center Design Requirements | |||||||
|---|---|---|---|---|---|---|---|
Required Minimum Yard Setbacks | |||||||
Use | Minimum Required Lot Width (feet) | Minimum Required Lot Depth (feet) | Front, as Measured from Street ROW | One Side** | Both Sides** | Rear | Minimum Required Setback from Either Residential Zone or Use as Specified Below* |
Shopping center, as defined herein, with up to 50,000 square feet of gross floor area | 250, at the building setback line | 250 | 35 feet for buildings and structures (except permitted signs); 20 feet for off-street parking; off-street loading or dumpsters are required to be placed between the rear wall of the building and the rear property line. (The rear wall shall be the wall closest to the rear property line.) | 50 feet for buildings and structures (except permitted signs); 15 feet for off-street parking and loading spaces and dumpsters | 50 feet for buildings and structures (except permitted signs); 30 feet for off-street parking and loading spaces and dumpsters | 25 feet for all buildings, structures, off-street parking and loading spaces and dumpsters | 50 feet for buildings, structures, off-street parking and loading spaces and dumpsters for both residential zone and a residential use outside of a residential zone |
Shopping center, as defined herein, with between 50,000 and 100,000 square feet of gross floor area | 300, at the building setback line | 500 | 50 feet for buildings and structures (except permitted signs); 25 feet for off-street parking; off-street loading or dumpsters are required to be placed between the rear wall of the building and the rear property line. (The rear wall shall be the wall closest to the rear property line.) | 60 feet for buildings and structures (except permitted signs); 20 feet for off-street parking and loading spaces and dumpsters | 60 feet for buildings and structures (except permitted signs); 40 feet for off-street parking and loading spaces and dumpsters | 30 feet for all buildings, structures, off-street parking and loading spaces and dumpsters | 100 feet for buildings, structures, off-street parking and loading spaces and dumpsters for residential zone, and 50 feet for buildings structures, off-street parking, loading spaces and dumpsters for a residential use outside of a residential zone |
Shopping center, as defined herein, over 100,000 square feet of gross floor area | 500, at the building setback line | 750 | 100 feet for buildings and structures (except permitted signs); 40 feet for off-street parking; off-street loading nor dumpsters are required to be placed between the rear wall of the building and the rear property line. (The rear wall shall be the wall closest to the rear property line.) | 100 feet for buildings and structures (except permitted signs); 25 feet for off-street parking and loading spaces and dumpsters | 100 feet for buildings and structures (except permitted signs); 50 feet for off-street parking and loading spaces and dumpsters | 40 feet for all buildings, structures, off street parking and loading spaces and dumpsters | 200 feet for buildings, structures, off-street parking and loading spaces and dumpsters for residential zone; 50 feet for buildings structures, off-street parking, loading spaces and dumpsters for residential use outside of a residential zone |
Shopping Center Design Requirements | |||||||
|---|---|---|---|---|---|---|---|
Required Minimum Yard Setbacks | |||||||
Use | Minimum Required Lot Width (feet) | Minimum Required Lot Depth (feet) | Front, as Measured from Street ROW | One Side** | Both Sides** | Rear | Minimum Required Setback from Either Residential Zone or Use as Specified Below* |
Shopping center, as defined herein, with up to 50,000 square feet of gross floor area | 250, at the building setback line | 250 | 35 feet for buildings and structures (except permitted signs); 20 feet for off-street parking; off-street loading or dumpsters are required to be placed between the rear wall of the building and the rear property line. (The rear wall shall be the wall closest to the rear property line.) | 50 feet for buildings and structures (except permitted signs); 15 feet for off-street parking and loading spaces and dumpsters | 50 feet for buildings and structures (except permitted signs); 30 feet for off-street parking and loading spaces and dumpsters | 25 feet for all buildings, structures, off-street parking and loading spaces and dumpsters | 50 feet for buildings, structures, off-street parking and loading spaces and dumpsters for both residential zone and a residential use outside of a residential zone |
Shopping center, as defined herein, with between 50,000 and 100,000 square feet of gross floor area | 300, at the building setback line | 500 | 50 feet for buildings and structures (except permitted signs); 25 feet for off-street parking; off-street loading or dumpsters are required to be placed between the rear wall of the building and the rear property line. (The rear wall shall be the wall closest to the rear property line.) | 60 feet for buildings and structures (except permitted signs); 20 feet for off-street parking and loading spaces and dumpsters | 60 feet for buildings and structures (except permitted signs); 40 feet for off-street parking and loading spaces and dumpsters | 30 feet for all buildings, structures, off-street parking and loading spaces and dumpsters | 100 feet for buildings, structures, off-street parking and loading spaces and dumpsters for residential zone, and 50 feet for buildings structures, off-street parking, loading spaces and dumpsters for a residential use outside of a residential zone |
Shopping center, as defined herein, over 100,000 square feet of gross floor area | 500, at the building setback line | 750 | 100 feet for buildings and structures (except permitted signs); 40 feet for off-street parking; off-street loading nor dumpsters are required to be placed between the rear wall of the building and the rear property line. (The rear wall shall be the wall closest to the rear property line.) | 100 feet for buildings and structures (except permitted signs); 25 feet for off-street parking and loading spaces and dumpsters | 100 feet for buildings and structures (except permitted signs); 50 feet for off-street parking and loading spaces and dumpsters | 40 feet for all buildings, structures, off street parking and loading spaces and dumpsters | 200 feet for buildings, structures, off-street parking and loading spaces and dumpsters for residential zone; 50 feet for buildings structures, off-street parking, loading spaces and dumpsters for residential use outside of a residential zone |
Type of Use | Minimum | Maximum |
|---|---|---|
Single-family detached | 20%*** | 60% |
Accessory apartment | 0% | 10% |
Single-family semidetached and two-family | 0% | 25% |
Single-family attached (townhouse style) | 0% | 40% |
Multiple-family | 5% | 40%** |
Live-work units | 0% | 15% |
Neighborhood commercial center* | 25% | 60% |
Civic uses* | 5% | 25% |
NOTES: | |
|---|---|
(All percentages in this table are based on number of residential units/total number of residential units.) | |
* | Measured as a percentage of total gross lot area. |
** | If all multiple-family units are age restricted then multiple-family maximum may be raised to 60%. |
*** | Existing or approved single-family detached lots located within 1,000 feet of the neighborhood center may be counted toward satisfying this minimum, provided sidewalk connects said single-family detached lots directly to the neighborhood center. |