Uses | Gross Floor Area (square feet) | Loading and Unloading (spaces required) |
|---|---|---|
Retail stores, wholesale establishments, storage uses and other business uses | 3,000 to 15,000 | 1 |
Retail stores, wholesale establishments, storage uses and other business uses | 15,001 to 40,000 | 2 |
Retail stores, wholesale establishments, storage uses and other business uses | Each 25,000 additional | 1 additional |
Industrial uses | 15,000 or less | 1 |
Industrial uses | 15,001 to 40,000 | 2 |
Industrial uses | 40,001 to 100,000 | 3 |
Industrial uses | Each 40,000 additional | 1 additional |
Use | Number of Spaces | |
|---|---|---|
Billiard room, pool hall | 1 for each 200 square feet of floor area | |
Boarding or lodging house | 1 for each 2 occupants | |
Bowling lanes | 5 for each lane | |
Church or temple, auditorium, arena, stadium, dance or assembly, hall, theater | 1 for each 5 seats | |
Dwelling: | ||
Single-family Two-family Multiple Home occupation | 1 2 2 for each unit 1 additional | |
Educational institution, private school, business or trade school | 2 for each 3 faculty and staff members plus 2 for each 5 students at the high school or college level | |
Funeral home or mortuary | 4 for each parlor or 1 for each 25 square feet of parlor floor area, whichever is greater | |
Hotel, motel or motor hotel, tourist home | 1 for each living or sleeping unit plus 1 for each 2 employees | |
Hospital, nursing home, home for the aged | 1 for each 4 beds plus 1 for each resident physician plus 1 for each 2 employees | |
Library or similar cultural facility | 1 for each 500 square feet of floor area | |
Medical office building | 1 for each 200 square feet of floor space | |
Mobile home park | 2 for each mobile home unit space plus 1 for each 2 employees | |
Passenger transportation terminal | 1 for each 3 seats in the waiting room plus 1 for each 2 employees | |
Private club or lodge | 1 for each 125 square feet of floor area | |
Private non-commercial recreation facility | As determined by the Board | |
Professional office (except medical offices) | 1 for each 200 square feet of floor area | |
Public recreation facility | As determined by the Board | |
Radio or television broadcasting studio | 1 for each 2 employees plus 1 for each 5 seats in the main studio or auditorium | |
Restaurant or tavern, nightclub and cocktail lounge over 500 square feet in floor area | 1 for each 125 square feet of floor area | |
Retail business, service establishment and business office under 2,000 square feet in floor area | 1 for each 200 square feet of sales floor area | |
Retail business, service establishment and business office 2,000 square feet or over in floor area | 1 for each 200 square feet of sales floor area | |
Wholesale business, warehouse freight terminal, junk yard manufacturing facility, public utility or industrial use (except a business office) | 1 for each 2 employees on the maximum shift or 1 for each 3,000 square feet of floor area, whichever is greater | |
All streets within the "PUD": Minimum of 30 feet or 28 feet with 3 foot sidewalks on both sides of the street. |
Tn-Total Duration Of Time Noise Permitted To Be Emitted From Noise Source During Period Of Measurement (Minutes) | A-Weighted Sound Pressure Level dB(A) | |
|---|---|---|
60 | 80 or less | |
30 | 81 — 83 | |
15 | 84 — 86 | |
8 | 87 — 89 | |
4 | 90 — 92 | |
2 | 93 — 95 | |
0 | 96 or greater |
Flammable* Liquid Storage | ||
|---|---|---|
Capacity of Tank (Gallons) | Class of Flammable Liquid*** | Distance (Feet) |
0 to 275 | III | 0 |
276 to 750 | III | 5 |
0 to 750 | I and II | 10 |
751 to 12,000 | III | 10 |
751 to 12,000 | I and II | 15 |
12,001 to 24,000 | I, II, III | 15 |
24,001 to 30,000 | I, II, III | 20 |
30,001 to 50,000 | I, II, III | 25 |
* A flammable liquid is defined as those liquids as defined by the most current issue of Booklet 30 of the National Fire Protection Association entitled Flammable and Combustible Liquid Code. ** When flammable gases are stored, utilized or manufactured and measured in cubic feet, the quantity in cubic feet (at S.T.P.) permitted shall not exceed three hundred (300) times the quantities listed. *** N.F.P.A. No. 321 Classes of Flammable Liquids. | ||
Class I Flash Point below one hundred degrees Fahrenheit (100°F). Class II Flash Point above one hundred degrees (100°) but below one hundred forty degrees Fahrenheit (140°F). Class III Flash Point above one hundred forty degrees Fahrenheit (140°F). | ||
Tanks in excess of fifty thousand (50,000) gallons and those for storage of crude petroleum shall be at a distance of three (3) times the greatest dimension of the diameter or height of tank, except that distance shall not be less than twenty (20) feet and not exceed three hundred fifty (350) feet from any "R" or "B" district boundary. |
Special Provisions
Uses | Gross Floor Area (square feet) | Loading and Unloading (spaces required) |
|---|---|---|
Retail stores, wholesale establishments, storage uses and other business uses | 3,000 to 15,000 | 1 |
Retail stores, wholesale establishments, storage uses and other business uses | 15,001 to 40,000 | 2 |
Retail stores, wholesale establishments, storage uses and other business uses | Each 25,000 additional | 1 additional |
Industrial uses | 15,000 or less | 1 |
Industrial uses | 15,001 to 40,000 | 2 |
Industrial uses | 40,001 to 100,000 | 3 |
Industrial uses | Each 40,000 additional | 1 additional |
Use | Number of Spaces | |
|---|---|---|
Billiard room, pool hall | 1 for each 200 square feet of floor area | |
Boarding or lodging house | 1 for each 2 occupants | |
Bowling lanes | 5 for each lane | |
Church or temple, auditorium, arena, stadium, dance or assembly, hall, theater | 1 for each 5 seats | |
Dwelling: | ||
Single-family Two-family Multiple Home occupation | 1 2 2 for each unit 1 additional | |
Educational institution, private school, business or trade school | 2 for each 3 faculty and staff members plus 2 for each 5 students at the high school or college level | |
Funeral home or mortuary | 4 for each parlor or 1 for each 25 square feet of parlor floor area, whichever is greater | |
Hotel, motel or motor hotel, tourist home | 1 for each living or sleeping unit plus 1 for each 2 employees | |
Hospital, nursing home, home for the aged | 1 for each 4 beds plus 1 for each resident physician plus 1 for each 2 employees | |
Library or similar cultural facility | 1 for each 500 square feet of floor area | |
Medical office building | 1 for each 200 square feet of floor space | |
Mobile home park | 2 for each mobile home unit space plus 1 for each 2 employees | |
Passenger transportation terminal | 1 for each 3 seats in the waiting room plus 1 for each 2 employees | |
Private club or lodge | 1 for each 125 square feet of floor area | |
Private non-commercial recreation facility | As determined by the Board | |
Professional office (except medical offices) | 1 for each 200 square feet of floor area | |
Public recreation facility | As determined by the Board | |
Radio or television broadcasting studio | 1 for each 2 employees plus 1 for each 5 seats in the main studio or auditorium | |
Restaurant or tavern, nightclub and cocktail lounge over 500 square feet in floor area | 1 for each 125 square feet of floor area | |
Retail business, service establishment and business office under 2,000 square feet in floor area | 1 for each 200 square feet of sales floor area | |
Retail business, service establishment and business office 2,000 square feet or over in floor area | 1 for each 200 square feet of sales floor area | |
Wholesale business, warehouse freight terminal, junk yard manufacturing facility, public utility or industrial use (except a business office) | 1 for each 2 employees on the maximum shift or 1 for each 3,000 square feet of floor area, whichever is greater | |
All streets within the "PUD": Minimum of 30 feet or 28 feet with 3 foot sidewalks on both sides of the street. |
Tn-Total Duration Of Time Noise Permitted To Be Emitted From Noise Source During Period Of Measurement (Minutes) | A-Weighted Sound Pressure Level dB(A) | |
|---|---|---|
60 | 80 or less | |
30 | 81 — 83 | |
15 | 84 — 86 | |
8 | 87 — 89 | |
4 | 90 — 92 | |
2 | 93 — 95 | |
0 | 96 or greater |
Flammable* Liquid Storage | ||
|---|---|---|
Capacity of Tank (Gallons) | Class of Flammable Liquid*** | Distance (Feet) |
0 to 275 | III | 0 |
276 to 750 | III | 5 |
0 to 750 | I and II | 10 |
751 to 12,000 | III | 10 |
751 to 12,000 | I and II | 15 |
12,001 to 24,000 | I, II, III | 15 |
24,001 to 30,000 | I, II, III | 20 |
30,001 to 50,000 | I, II, III | 25 |
* A flammable liquid is defined as those liquids as defined by the most current issue of Booklet 30 of the National Fire Protection Association entitled Flammable and Combustible Liquid Code. ** When flammable gases are stored, utilized or manufactured and measured in cubic feet, the quantity in cubic feet (at S.T.P.) permitted shall not exceed three hundred (300) times the quantities listed. *** N.F.P.A. No. 321 Classes of Flammable Liquids. | ||
Class I Flash Point below one hundred degrees Fahrenheit (100°F). Class II Flash Point above one hundred degrees (100°) but below one hundred forty degrees Fahrenheit (140°F). Class III Flash Point above one hundred forty degrees Fahrenheit (140°F). | ||
Tanks in excess of fifty thousand (50,000) gallons and those for storage of crude petroleum shall be at a distance of three (3) times the greatest dimension of the diameter or height of tank, except that distance shall not be less than twenty (20) feet and not exceed three hundred fifty (350) feet from any "R" or "B" district boundary. |