Design and Performance Standards
Table 1 Off-Site Use/Designated Line Separation Distance | ||
|---|---|---|
(measured from the nearest point of the tower or structure tower or structure upon which the antennas are mounted to the structure of the off-site use or designated line) | ||
Residence district, low-density residence district, low and moderate residential district, senior citizen overlay district | 300 feet or 300% of the height of the tower or existing structure, whichever is greater, measured to the residential unit | |
Vacant land in the residence district, low-density residence district, low and moderate residential district, and senior citizen overlay district which is either platted or has preliminary subdivision plan approval which is not expired | 300 feet or 300% of the height of the tower or existing structure, whichever is greater, measured to the building setback line of the off-site use | |
Vacant unplatted residentially zoned lands | 150 feet or 150% of the height of the tower or existing structure, whichever is greater, measured to the property line | |
Public park or conservation area | 150 feet or 150% of the height of the tower or existing structure, whichever is greater, measured to the property line | |
Nonresidentially zoned lands or nonresidentially uses. | Setbacks apply pursuant to Subsection H(2) above. | |
Minimum Top Widths | ||
|---|---|---|
Height (feet) | Top Width (feet) | |
0 to 15 | 10 | |
15 to 20 | 12 | |
20 to 35 | 14 | |
Storm Event (year) | Total Rainfall (inches) | |
|---|---|---|
1 | 2.8 | |
2 | 3.5 | |
10 | 5.5 | |
50 | 6.8 | |
100 | 7.6 |
Surface | Minimum C | |
|---|---|---|
Structures; pavements | 0.90 | |
Cultivated dense or clay soils | 0.30 | |
Cultivated sand or loam soils | 0.25 | |
Meadows; rural areas | 0.20 | |
Heavily wooded areas | 0.15 |
Development | Minimum C | |
|---|---|---|
To limits of improvements | 0.70 | |
One-fourth-acre residential | 0.50 | |
One-half-acre residential | 0.40 | |
One-acre residential | 0.30 |
Minimum (feet) | Maximum (feet) | ||
|---|---|---|---|
Industrial | 25 | 35 | |
Commercial | 20 | 35 | |
Multifamily | 20 | 35 | |
One- and two-family | 20 | 20 | |
Public and quasi-public | 20 | 35 |
Lot width | 150 feet | |
Lot depth | 200 feet | |
Front yard | 45 feet* | |
Side yard | 25 feet* | |
Rear yard | 40 feet* | |
*Notwithstanding the minimum yard requirements, the minimum setback from the center line of any existing or proposed electric company's transmission/distribution supply line or electric substations shall be 200 feet. This setback shall not apply to 13kv local service lines or service connections to individual buildings. | ||
Minimum Size of Required Recreation Areas | |||
|---|---|---|---|
Maximum Number of Children | All Children Under Age 6 (square feet) | One or More Children Age 6 and Over (square feet) | |
25 | 1,000 | 2,000 | |
26 - 50 | 2,000 | 4,000 | |
51 - 75 | 3,000 | 6,000 | |
76 - 100 | 4,000 | 8,000 | |
Table 1 | |||||
|---|---|---|---|---|---|
Map Panel No. | Effective Date | Suffix | Map Panel No. | Effective Date | Suffix |
34015C0182 | January 20, 2010 | E | 34015C 0204 | January 20, 2010 | E |
34015C0201 | January 20, 2010 | E | 34015C 0191 | January 20, 2010 | E |
34015C0183 | January 20, 2010 | E | 34015C 0211 | January 20, 2010 | E |
34015C0184 | January 20, 2010 | E | 34015C 0212 | January 20, 2010 | E |
34015C0203 | January 20, 2010 | E | 34015C 0216 | January 20, 2010 | E |
34015C0192 | January 20, 2010 | E | |||
Table 3: List of State Studied Waters | ||
|---|---|---|
Name of Studied Water | File Name | Map Number |
Duffield Run | SUPPXI11 | DR-1 |
Duffield Run | SUPPXI12 | DR-2 |
Mantua Creek | SUPPXI23 | MC-1 |
Mantua Creek | SUPPXI24 | MC-2 |
Use | Average Footcandles | ||
|---|---|---|---|
High activity: | |||
Parking lots/walkways in business and similar areas | 2 | ||
Commercial loading areas | 10 | ||
Basketball and tennis courts | 10 | ||
Playgrounds (general) | 5 | ||
Medium activity: | |||
Streetlighting at intersections | 1.2 | ||
Streetlighting at mid-block and similar locations | 0.6 | ||
Low activity: | |||
Lighting along rural roads and similar locations | 0.8 | ||
Angle of Parking Space | One-Way Aisle (feet) | Two-Way Aisle (feet) | |
|---|---|---|---|
90 | 24 | 24 | |
60 | 18 | 24 | |
45 | 15 | 24 | |
30 | 12 | 24 | |
Parallel | 12 | 24 |
Loading Space | Apron/Aisle Length | ||||
|---|---|---|---|---|---|
Length (feet) | Width (feet) | 90 (feet) | 60 (feet) | ||
60 | 10 | 72 | 66 | ||
60 | 12 | 63 | 57 | ||
60 | 14 | 60 | 54 | ||
Minimum Loading Requirements | |||||
|---|---|---|---|---|---|
Gross Floor Area | |||||
Uses | Minimum Number of Loading Spaces* | At Which First Berth is Required | At Which Second Berth is Required | Number of Additional Square Feet For Each Additional Berth | |
Residential, church, school, pool, firehouse, golf course, day-care center, service station, movie theater, car wash | —— No spaces required —— | ||||
Auto/truck sales | 1 | 10,000 | 40,000 | 40,000 | |
Bowling alley | 1 | 10,000 | 100,000 | 100,000 | |
College administration facilities | 1 | 10,000 | 100,000 | 100,000 | |
Contractor's yard | 1 | 10,000 | 25,000 | 20,000 | |
Dormitories | 1 | 25,000 | 100,000 | 100,000 | |
Financial institution | 0 | 10,000 | 100,000 | 100,000 | |
Hospital | 1 | 10,000 | 100,000 | 100,000 | |
Library | 0 | 10,000 | 100,000 | 100,000 | |
Lumberyard | 1 | 10,000 | 25,000 | 20,000 | |
Manufacturing, assembly, fabricating | 1 | 5,000 | 40,000 | 30,000 | |
Mortuary | 1 | 10,000 | 100,000 | 100,000 | |
Motel | 1 | 10,000 | 100,000 | 100,000 | |
Municipal building | 0 | 10,000 | 100,000 | 100,000 | |
Nightclub | 1 | 10,000 | 25,000 | 20,000 | |
Offices | 1 | 10,000 | 100,000 | 100,000 | |
Personal service | 0 | 10,000 | 20,000 | 20,000 | |
Research | 1 | 5,000 | 40,000 | 40,000 | |
Restaurant | 1 | 10,000 | 25,000 | 20,000 | |
Retail store | 1 | 10,000 | 20,000 | 20,000 | |
Shopping center | 1 | 10,000 | 40,000 | 40,000 | |
Veterinary hospital | 1 | 10,000 | 100,000 | 100,000 | |
Warehouse, shipping and receiving | 1 | 5,000 | 40,000 | 30,000 | |
Wholesale fuel distribution | 1 | 10,000 | 40,000 | 30,000 | |
*NOTE: The minimum number of spaces shall prevail for uses that have not attained the gross floor area where the first space is required. |
Minimum Parking Requirements | |
|---|---|
Use | Minimum Number of Spaces [Gross Floor Area (GFA)] |
Auto/truck sales | 1 per 50 square feet of showroom area and sales office |
Banquet hall | 1 per 3 seats |
Bowling alley | 4 per alley |
Boardinghouse (which shall include but is not limited to a residential dwelling wherein one or more rooms within said residential building are rented or sublet to 1 or more persons) | 1 per boarder |
Car wash | 8 per washing lane |
Catering hall | 1 per 3 seats |
Church | 1 per 5 seats |
College administration facilities | 1 per 200 square feet of GFA |
Community swimming pool | 1 per 15 square feet of water surface area |
Day-care center | 1 per 600 square feet |
Dormitories | 1 per occupant |
Drive-up window services | 8 vehicles per lane with each lane designed to be separate from other on-site circulation and parking areas. There shall be one bypass lane. |
Financial institution | 1 per 250 square feet of GFA |
Firehouse | 1 per 400 square feet of GFA |
Fraternity house | 1 per occupant |
Golf course | 4 per hole |
Library | 1 per 300 square feet of GFA |
Lumber and contractor's yard | 1 per 5,000 square feet of GFA |
Manufacture, assembly, fabrication | 1 per 800 square feet of GFA |
Medical facility | 1 per 200 square feet of GFA, but not less than 3 spaces per examination/treatment room |
Meeting halls | 1 per 3 seats |
Mortuaries | 15 per viewing room and chapel |
Motel | 1.1 per unit |
Movie theater | 1 per 4 seats |
Municipal building | 1 per 600 square feet of GFA |
Nightclub | 1 per 3 seats |
Offices | 1 per 200 square feet of GFA |
Personal service | 1 per 150 square feet of GFA |
Research | 1 per 1,000 square feet of GFA |
Residential units: | |
Detached dwelling | 2 (See Note 1.) |
Structure with 2 dwelling units | 4 (See Note 1.) |
Townhouse | 2 per unit (See Note 2.) |
Garden apartments | 2 per unit (See Note 2.) |
Per rented room | 1 |
Restaurant | |
Sit down | 1 per 3 seats |
Take-out, no seats | 1 per 40 square feet GFA |
For window service, see "drive-up window services" | |
Combination | 1 per 3 seats plus 1 per 40 square feet of floor are devoted customer waiting in front of the counter, the counter itself, and the area for employee cooking and serving behind the counter |
Retail store (see also shopping center) | 1 per 200 square feet of gross floor area |
Schools: | |
Elementary school | 1.2 per classroom; minimum 1 teacher and staff |
Intermediate school | 1.5 per classroom; minimum 1 teacher and staff |
Secondary school | 2.5 per classroom; minimum 2 teachers and staff |
Senior citizen developments (age 62+) | |
Detached dwelling | 2 (See Note 1.) |
Structure with 2 dwelling units | 4 (See Note 1.) |
Townhouse | 1.5 per unit (See Note 2.) |
Garden apartments | 1.25 per unit (See Note 2.) |
Service station | 4 per bay and work area plus one space per 300 square feet of gross floor area devoted to a convenience stores, said spaces being separate from the service station lanes and service areas |
Shopping center3 | 4.0 per 1,000 with GFA less than 400,000 square feet |
4.5 per 1,000 with GFA 400,000 to 600,000 square feet | |
5.0 per 1,000 with GFA 600,000 plus 2 per bedroom | |
Sorority house | 2 per bedroom |
Student housing rental house | 1.8 for 1 bedroom, 2.0 for 2 bedrooms, 2.1 for 3 bedrooms, plus 1 additional space per bedroom thereafter. Note that when a parking calculation for the entire development results in a fraction of 1/2 or less, that portion can be disregarded, while a calculation of more than 1/2 shall count as an additional space |
Veterinary hospital | 4 per examination room or doctor, whichever is greater |
Warehouse, shipping and receiving | 1 per 5,000 square feet of gross floor area |
Wholesale fuel distribution | 1 per 10,000 square feet of gross yard area required for the use. |
NOTE 1: The last 25 feet of the driveway closest to the building shall be at least 20 feet wide to allow side-by-side parking. |
NOTE 2: At least 0.5 space per unit shall be provided for guest parking in scattered parking areas reasonably distributed throughout the development. Where the parking is in assigned spaces (such as garages and driveways) and where one space blocks another (such as driveway space blocking the space in the garage), each assigned and/or blocked space shall require an additional 0.25 space above the minimum of two spaces per dwelling unit. |
NOTE 3: Maximum 20% of gross floor area can be office use without additional parking for the office use. Office use above 20% shall require parking at the appropriate rate. |
Maximum Operating Speed (mph) | Minimum Sight Distance (feet) | |
|---|---|---|
20 | 165 | |
30 | 253 | |
40 | 407 | |
50 | 572 | |
60 | 720 |
Table A | ||||
|---|---|---|---|---|
Setback of the Building from the Sign | Percent of Extended Facade Area1 (percent) | Percent of Wall Area2 (percent) | Vertical Height of Sign Structure (feet) | Maximum Area (square feet) |
Within 50 feet of street right-of-way | 10% | 5% | 4 | 60 |
51 feet to 100 feet | 14% | 7% | 5 | 80 |
101 feet to 200 feet | 18% | 9% | 6 | 100 |
201 feet to 300 feet | 22% | 11% | 7 | 120 |
More than 300 feet | 24% | 12% | 8 | 140 |
NOTE 1. Where facade extends more than two feet from the wall. |
NOTE 2. Wall with no facade or where the facade extends no more than two feet from the wall. |
Street Classification | Right-of-Way Width (feet) | Width Between Curbs (feet) | |
|---|---|---|---|
Arterial | 80 | 60 | |
Collector | 60 | 40 | |
Primary local | 56 | 34 | |
Secondary local | 50 | 32 |
Design and Performance Standards
Table 1 Off-Site Use/Designated Line Separation Distance | ||
|---|---|---|
(measured from the nearest point of the tower or structure tower or structure upon which the antennas are mounted to the structure of the off-site use or designated line) | ||
Residence district, low-density residence district, low and moderate residential district, senior citizen overlay district | 300 feet or 300% of the height of the tower or existing structure, whichever is greater, measured to the residential unit | |
Vacant land in the residence district, low-density residence district, low and moderate residential district, and senior citizen overlay district which is either platted or has preliminary subdivision plan approval which is not expired | 300 feet or 300% of the height of the tower or existing structure, whichever is greater, measured to the building setback line of the off-site use | |
Vacant unplatted residentially zoned lands | 150 feet or 150% of the height of the tower or existing structure, whichever is greater, measured to the property line | |
Public park or conservation area | 150 feet or 150% of the height of the tower or existing structure, whichever is greater, measured to the property line | |
Nonresidentially zoned lands or nonresidentially uses. | Setbacks apply pursuant to Subsection H(2) above. | |
Minimum Top Widths | ||
|---|---|---|
Height (feet) | Top Width (feet) | |
0 to 15 | 10 | |
15 to 20 | 12 | |
20 to 35 | 14 | |
Storm Event (year) | Total Rainfall (inches) | |
|---|---|---|
1 | 2.8 | |
2 | 3.5 | |
10 | 5.5 | |
50 | 6.8 | |
100 | 7.6 |
Surface | Minimum C | |
|---|---|---|
Structures; pavements | 0.90 | |
Cultivated dense or clay soils | 0.30 | |
Cultivated sand or loam soils | 0.25 | |
Meadows; rural areas | 0.20 | |
Heavily wooded areas | 0.15 |
Development | Minimum C | |
|---|---|---|
To limits of improvements | 0.70 | |
One-fourth-acre residential | 0.50 | |
One-half-acre residential | 0.40 | |
One-acre residential | 0.30 |
Minimum (feet) | Maximum (feet) | ||
|---|---|---|---|
Industrial | 25 | 35 | |
Commercial | 20 | 35 | |
Multifamily | 20 | 35 | |
One- and two-family | 20 | 20 | |
Public and quasi-public | 20 | 35 |
Lot width | 150 feet | |
Lot depth | 200 feet | |
Front yard | 45 feet* | |
Side yard | 25 feet* | |
Rear yard | 40 feet* | |
*Notwithstanding the minimum yard requirements, the minimum setback from the center line of any existing or proposed electric company's transmission/distribution supply line or electric substations shall be 200 feet. This setback shall not apply to 13kv local service lines or service connections to individual buildings. | ||
Minimum Size of Required Recreation Areas | |||
|---|---|---|---|
Maximum Number of Children | All Children Under Age 6 (square feet) | One or More Children Age 6 and Over (square feet) | |
25 | 1,000 | 2,000 | |
26 - 50 | 2,000 | 4,000 | |
51 - 75 | 3,000 | 6,000 | |
76 - 100 | 4,000 | 8,000 | |
Table 1 | |||||
|---|---|---|---|---|---|
Map Panel No. | Effective Date | Suffix | Map Panel No. | Effective Date | Suffix |
34015C0182 | January 20, 2010 | E | 34015C 0204 | January 20, 2010 | E |
34015C0201 | January 20, 2010 | E | 34015C 0191 | January 20, 2010 | E |
34015C0183 | January 20, 2010 | E | 34015C 0211 | January 20, 2010 | E |
34015C0184 | January 20, 2010 | E | 34015C 0212 | January 20, 2010 | E |
34015C0203 | January 20, 2010 | E | 34015C 0216 | January 20, 2010 | E |
34015C0192 | January 20, 2010 | E | |||
Table 3: List of State Studied Waters | ||
|---|---|---|
Name of Studied Water | File Name | Map Number |
Duffield Run | SUPPXI11 | DR-1 |
Duffield Run | SUPPXI12 | DR-2 |
Mantua Creek | SUPPXI23 | MC-1 |
Mantua Creek | SUPPXI24 | MC-2 |
Use | Average Footcandles | ||
|---|---|---|---|
High activity: | |||
Parking lots/walkways in business and similar areas | 2 | ||
Commercial loading areas | 10 | ||
Basketball and tennis courts | 10 | ||
Playgrounds (general) | 5 | ||
Medium activity: | |||
Streetlighting at intersections | 1.2 | ||
Streetlighting at mid-block and similar locations | 0.6 | ||
Low activity: | |||
Lighting along rural roads and similar locations | 0.8 | ||
Angle of Parking Space | One-Way Aisle (feet) | Two-Way Aisle (feet) | |
|---|---|---|---|
90 | 24 | 24 | |
60 | 18 | 24 | |
45 | 15 | 24 | |
30 | 12 | 24 | |
Parallel | 12 | 24 |
Loading Space | Apron/Aisle Length | ||||
|---|---|---|---|---|---|
Length (feet) | Width (feet) | 90 (feet) | 60 (feet) | ||
60 | 10 | 72 | 66 | ||
60 | 12 | 63 | 57 | ||
60 | 14 | 60 | 54 | ||
Minimum Loading Requirements | |||||
|---|---|---|---|---|---|
Gross Floor Area | |||||
Uses | Minimum Number of Loading Spaces* | At Which First Berth is Required | At Which Second Berth is Required | Number of Additional Square Feet For Each Additional Berth | |
Residential, church, school, pool, firehouse, golf course, day-care center, service station, movie theater, car wash | —— No spaces required —— | ||||
Auto/truck sales | 1 | 10,000 | 40,000 | 40,000 | |
Bowling alley | 1 | 10,000 | 100,000 | 100,000 | |
College administration facilities | 1 | 10,000 | 100,000 | 100,000 | |
Contractor's yard | 1 | 10,000 | 25,000 | 20,000 | |
Dormitories | 1 | 25,000 | 100,000 | 100,000 | |
Financial institution | 0 | 10,000 | 100,000 | 100,000 | |
Hospital | 1 | 10,000 | 100,000 | 100,000 | |
Library | 0 | 10,000 | 100,000 | 100,000 | |
Lumberyard | 1 | 10,000 | 25,000 | 20,000 | |
Manufacturing, assembly, fabricating | 1 | 5,000 | 40,000 | 30,000 | |
Mortuary | 1 | 10,000 | 100,000 | 100,000 | |
Motel | 1 | 10,000 | 100,000 | 100,000 | |
Municipal building | 0 | 10,000 | 100,000 | 100,000 | |
Nightclub | 1 | 10,000 | 25,000 | 20,000 | |
Offices | 1 | 10,000 | 100,000 | 100,000 | |
Personal service | 0 | 10,000 | 20,000 | 20,000 | |
Research | 1 | 5,000 | 40,000 | 40,000 | |
Restaurant | 1 | 10,000 | 25,000 | 20,000 | |
Retail store | 1 | 10,000 | 20,000 | 20,000 | |
Shopping center | 1 | 10,000 | 40,000 | 40,000 | |
Veterinary hospital | 1 | 10,000 | 100,000 | 100,000 | |
Warehouse, shipping and receiving | 1 | 5,000 | 40,000 | 30,000 | |
Wholesale fuel distribution | 1 | 10,000 | 40,000 | 30,000 | |
*NOTE: The minimum number of spaces shall prevail for uses that have not attained the gross floor area where the first space is required. |
Minimum Parking Requirements | |
|---|---|
Use | Minimum Number of Spaces [Gross Floor Area (GFA)] |
Auto/truck sales | 1 per 50 square feet of showroom area and sales office |
Banquet hall | 1 per 3 seats |
Bowling alley | 4 per alley |
Boardinghouse (which shall include but is not limited to a residential dwelling wherein one or more rooms within said residential building are rented or sublet to 1 or more persons) | 1 per boarder |
Car wash | 8 per washing lane |
Catering hall | 1 per 3 seats |
Church | 1 per 5 seats |
College administration facilities | 1 per 200 square feet of GFA |
Community swimming pool | 1 per 15 square feet of water surface area |
Day-care center | 1 per 600 square feet |
Dormitories | 1 per occupant |
Drive-up window services | 8 vehicles per lane with each lane designed to be separate from other on-site circulation and parking areas. There shall be one bypass lane. |
Financial institution | 1 per 250 square feet of GFA |
Firehouse | 1 per 400 square feet of GFA |
Fraternity house | 1 per occupant |
Golf course | 4 per hole |
Library | 1 per 300 square feet of GFA |
Lumber and contractor's yard | 1 per 5,000 square feet of GFA |
Manufacture, assembly, fabrication | 1 per 800 square feet of GFA |
Medical facility | 1 per 200 square feet of GFA, but not less than 3 spaces per examination/treatment room |
Meeting halls | 1 per 3 seats |
Mortuaries | 15 per viewing room and chapel |
Motel | 1.1 per unit |
Movie theater | 1 per 4 seats |
Municipal building | 1 per 600 square feet of GFA |
Nightclub | 1 per 3 seats |
Offices | 1 per 200 square feet of GFA |
Personal service | 1 per 150 square feet of GFA |
Research | 1 per 1,000 square feet of GFA |
Residential units: | |
Detached dwelling | 2 (See Note 1.) |
Structure with 2 dwelling units | 4 (See Note 1.) |
Townhouse | 2 per unit (See Note 2.) |
Garden apartments | 2 per unit (See Note 2.) |
Per rented room | 1 |
Restaurant | |
Sit down | 1 per 3 seats |
Take-out, no seats | 1 per 40 square feet GFA |
For window service, see "drive-up window services" | |
Combination | 1 per 3 seats plus 1 per 40 square feet of floor are devoted customer waiting in front of the counter, the counter itself, and the area for employee cooking and serving behind the counter |
Retail store (see also shopping center) | 1 per 200 square feet of gross floor area |
Schools: | |
Elementary school | 1.2 per classroom; minimum 1 teacher and staff |
Intermediate school | 1.5 per classroom; minimum 1 teacher and staff |
Secondary school | 2.5 per classroom; minimum 2 teachers and staff |
Senior citizen developments (age 62+) | |
Detached dwelling | 2 (See Note 1.) |
Structure with 2 dwelling units | 4 (See Note 1.) |
Townhouse | 1.5 per unit (See Note 2.) |
Garden apartments | 1.25 per unit (See Note 2.) |
Service station | 4 per bay and work area plus one space per 300 square feet of gross floor area devoted to a convenience stores, said spaces being separate from the service station lanes and service areas |
Shopping center3 | 4.0 per 1,000 with GFA less than 400,000 square feet |
4.5 per 1,000 with GFA 400,000 to 600,000 square feet | |
5.0 per 1,000 with GFA 600,000 plus 2 per bedroom | |
Sorority house | 2 per bedroom |
Student housing rental house | 1.8 for 1 bedroom, 2.0 for 2 bedrooms, 2.1 for 3 bedrooms, plus 1 additional space per bedroom thereafter. Note that when a parking calculation for the entire development results in a fraction of 1/2 or less, that portion can be disregarded, while a calculation of more than 1/2 shall count as an additional space |
Veterinary hospital | 4 per examination room or doctor, whichever is greater |
Warehouse, shipping and receiving | 1 per 5,000 square feet of gross floor area |
Wholesale fuel distribution | 1 per 10,000 square feet of gross yard area required for the use. |
NOTE 1: The last 25 feet of the driveway closest to the building shall be at least 20 feet wide to allow side-by-side parking. |
NOTE 2: At least 0.5 space per unit shall be provided for guest parking in scattered parking areas reasonably distributed throughout the development. Where the parking is in assigned spaces (such as garages and driveways) and where one space blocks another (such as driveway space blocking the space in the garage), each assigned and/or blocked space shall require an additional 0.25 space above the minimum of two spaces per dwelling unit. |
NOTE 3: Maximum 20% of gross floor area can be office use without additional parking for the office use. Office use above 20% shall require parking at the appropriate rate. |
Maximum Operating Speed (mph) | Minimum Sight Distance (feet) | |
|---|---|---|
20 | 165 | |
30 | 253 | |
40 | 407 | |
50 | 572 | |
60 | 720 |
Table A | ||||
|---|---|---|---|---|
Setback of the Building from the Sign | Percent of Extended Facade Area1 (percent) | Percent of Wall Area2 (percent) | Vertical Height of Sign Structure (feet) | Maximum Area (square feet) |
Within 50 feet of street right-of-way | 10% | 5% | 4 | 60 |
51 feet to 100 feet | 14% | 7% | 5 | 80 |
101 feet to 200 feet | 18% | 9% | 6 | 100 |
201 feet to 300 feet | 22% | 11% | 7 | 120 |
More than 300 feet | 24% | 12% | 8 | 140 |
NOTE 1. Where facade extends more than two feet from the wall. |
NOTE 2. Wall with no facade or where the facade extends no more than two feet from the wall. |
Street Classification | Right-of-Way Width (feet) | Width Between Curbs (feet) | |
|---|---|---|---|
Arterial | 80 | 60 | |
Collector | 60 | 40 | |
Primary local | 56 | 34 | |
Secondary local | 50 | 32 |