Administration and Enforcement
Figure 405.26 Overview of the Development Review Process |
NOTES: | |
1 | "Planning" refers to the City of Kingston Planning Administrator (the Planning Director or their designee). |
2 | This diagram is illustrative in nature; the development review process may vary. All necessary steps will be confirmed with each applicant based on the details of each specific proposal. |
Table 405.26.F Defined Minor Waivers and Major Waivers | ||||
|---|---|---|---|---|
Reference to Standard | Required Findings | Defined Minor Waiver Relief | Defined Major Waiver | Public Notification/Approval Agency |
Avoid impacts to sensitive natural features, such as steep slopes, exposed rock formations, sensitive habitats, wetlands and floodplains, and mature trees | Building placement standards may be adjusted by the minimum extent needed to avoid impact to sensitive natural features. | n/a | No/Planning Administrator | |
Consistency with planning, design and compatibility intent set forth in each Transect Zone | 10% maximum deviation in numeric dimensional standards (excluding building height) | n/a | No/Planning Administrator | |
Support the adaptive reuse of existing structures | n/a | Maximum building footprint may be expanded by up to 100% of the size of the existing building footprint for new additions | Yes/Planning Board | |
Increase value of site and adjacent lots by maintaining the Transect Zone block dimensions, frontage occupancy , and parking placement | n/a | Grocery stores may exceed the maximum building footprint | Yes/Planning Board | |
§ 405-11, Special District Waterfront | Architectural articulation, landscaping or other appropriate screening that shields views of parking or blank walls at the ground level from the waterfront, streets and pedestrian spaces | Parking permitted below the first story without a liner building | n/a | No/Planning Administrator |
§ 405-12, Building type standards | Consistency with planning, design and compatibility intent set forth in each Transect Zone | n/a | Proposal of additional building types not listed in § 405-12 | Yes/Planning Board |
§ 405-12, building type dimensional standards | Consistency with planning, design and compatibility intent set forth in each Transect Zone | 10% maximum deviation in numeric dimensional standards | n/a | No/Planning Administrator |
Consistency with planning, design and compatibility intent set forth in each Transect Zone | Building wider than 150 feet but meets the requirements for wide buildings [§ 405-14C(4)] | n/a | No/Planning Administrator | |
Consistency with planning, design and compatibility intent set forth in each Transect Zone | n/a | Up to 2 ADU per lot (one attached and one detached) | Yes/Planning Board | |
§ 405-14, Architecture and site design standards | Consistency with planning, design and compatibility intent set forth in each Transect Zone | 10% maximum deviation in numeric dimensional standards | n/a | No/Planning Administrator |
§ 405-14C, Facade composition | Architectural articulation, landscaping or other appropriate screening that shields views of parking or blank walls at the ground level from the waterfront, streets and pedestrian spaces | Exceptions to the facade composition requirements for the portion of facade below the first story | n/a | No/Planning Administrator |
§ 405-14D(5), shopfronts | Site constraints | Shopfront entrances at intervals greater than 50 feet apart | n/a | No/Planning Administrator |
§ 405-14G(5), screening of mechanical equipment and service areas | When equipment is taller than the maximum height for garden walls and fences | Garden wall and fence height may be extended to match that of at-grade mechanical equipment | n/a | No/Planning Administrator |
§ 405-14K(3), Steep slopes | Physical constraints | n/a | Development on ground which has an incline of 10% to 25% | Yes/Planning Board |
§ 405-15C, Waterfront Overlay, public access | Site constraints or incompatible uses | n/a | No public access on parcels outside of the SD-WMU | Yes/Planning Board |
| § 405-15D, Waterfront Overlay standards | Proposed outdoor storage consists of cultural exhibits/displays or maritime attractions that positively contribute to the waterfront pedestrian setting. | Exceptions to required screening of outdoor storage areas | n/a | No/Planning Administrator |
§ 405-16C, Parking requirements | Unique site or use circumstances | n/a | Exceptions to maximum parking limits | Yes/Planning Board |
§ 405-16E, parking access | Unique site circumstances (corner lot , or existing horseshoe driveway) | One additional curb cut permitted | n/a | No/Planning Administrator |
§ 405-16F, Parking lot landscape standards | Unique site or use circumstances | n/a | Nonpermeable streetscreens | Yes/Planning Board |
§ 405-17E, Pedestrian-oriented signs | Unique architectural qualities of a building, a building's historical significance, a building's civic or institutional use , civic prominence, or unique configuration of existing conditions of a building, as well as the quality of design, construction, and durability of the sign | Signage that does not fit the specific regulations of § 405-17 but meets the intent of this chapter | n/a | No/Planning Administrator |
§ 405-23B, right-of-way width | Physical constraints (existing buildings or natural features) | New street right-of-way width less than 45 feet | n/a | No/Planning Administrator |
§ 405-24C(1), minimum usable open space | Restrictive lot dimension or physical constraints (existing buildings or natural features) | n/a | Less than 10% usable open space provided | Yes/Planning Board |
§ 405-24C(6), steep slopes, floodplain or other natural areas | Providing improved, usable access to natural features | 50% maximum allocation of overall 10% minimum public usable open space | n/a | No/Planning Administrator |
§ 405-24C(2), usable open space in a CVP or WNP | Design constraint, such as restrictive lot dimension or physical constraints (existing buildings or natural features) | Backing buildings onto a shared usable open space | n/a | No/Planning Administrator |
§ 405-25C(1)(b), Transect Zone allocation | 80% of proposed housing units meet the requirements of § 405-19 for affordable housing | n/a | 10% to 40% of the CVP may be T5N | Yes/Planning Board |
§ 405-25C(2)(d), External connectivity | Physical conditions, such as highways, sensitive natural resources, or unusual topography provide no practical connection alternatives. | Proposed dead end must be detailed as a close (a small green area surrounded by a common driveway serving adjoining lots) and should provide pedestrian connectivity to the maximum extent practicable. | n/a | No/Planning Administrator |
§ 405-25C(2)(e), Block size | Topographic or site constraints | Blocks larger than set standards per transect | n/a | No/Planning Administrator |
Note: | ||||
Required findings shall be based on the intent of this chapter or non-self-imposed hardship. |
Administration and Enforcement
Figure 405.26 Overview of the Development Review Process |
NOTES: | |
1 | "Planning" refers to the City of Kingston Planning Administrator (the Planning Director or their designee). |
2 | This diagram is illustrative in nature; the development review process may vary. All necessary steps will be confirmed with each applicant based on the details of each specific proposal. |
Table 405.26.F Defined Minor Waivers and Major Waivers | ||||
|---|---|---|---|---|
Reference to Standard | Required Findings | Defined Minor Waiver Relief | Defined Major Waiver | Public Notification/Approval Agency |
Avoid impacts to sensitive natural features, such as steep slopes, exposed rock formations, sensitive habitats, wetlands and floodplains, and mature trees | Building placement standards may be adjusted by the minimum extent needed to avoid impact to sensitive natural features. | n/a | No/Planning Administrator | |
Consistency with planning, design and compatibility intent set forth in each Transect Zone | 10% maximum deviation in numeric dimensional standards (excluding building height) | n/a | No/Planning Administrator | |
Support the adaptive reuse of existing structures | n/a | Maximum building footprint may be expanded by up to 100% of the size of the existing building footprint for new additions | Yes/Planning Board | |
Increase value of site and adjacent lots by maintaining the Transect Zone block dimensions, frontage occupancy , and parking placement | n/a | Grocery stores may exceed the maximum building footprint | Yes/Planning Board | |
§ 405-11, Special District Waterfront | Architectural articulation, landscaping or other appropriate screening that shields views of parking or blank walls at the ground level from the waterfront, streets and pedestrian spaces | Parking permitted below the first story without a liner building | n/a | No/Planning Administrator |
§ 405-12, Building type standards | Consistency with planning, design and compatibility intent set forth in each Transect Zone | n/a | Proposal of additional building types not listed in § 405-12 | Yes/Planning Board |
§ 405-12, building type dimensional standards | Consistency with planning, design and compatibility intent set forth in each Transect Zone | 10% maximum deviation in numeric dimensional standards | n/a | No/Planning Administrator |
Consistency with planning, design and compatibility intent set forth in each Transect Zone | Building wider than 150 feet but meets the requirements for wide buildings [§ 405-14C(4)] | n/a | No/Planning Administrator | |
Consistency with planning, design and compatibility intent set forth in each Transect Zone | n/a | Up to 2 ADU per lot (one attached and one detached) | Yes/Planning Board | |
§ 405-14, Architecture and site design standards | Consistency with planning, design and compatibility intent set forth in each Transect Zone | 10% maximum deviation in numeric dimensional standards | n/a | No/Planning Administrator |
§ 405-14C, Facade composition | Architectural articulation, landscaping or other appropriate screening that shields views of parking or blank walls at the ground level from the waterfront, streets and pedestrian spaces | Exceptions to the facade composition requirements for the portion of facade below the first story | n/a | No/Planning Administrator |
§ 405-14D(5), shopfronts | Site constraints | Shopfront entrances at intervals greater than 50 feet apart | n/a | No/Planning Administrator |
§ 405-14G(5), screening of mechanical equipment and service areas | When equipment is taller than the maximum height for garden walls and fences | Garden wall and fence height may be extended to match that of at-grade mechanical equipment | n/a | No/Planning Administrator |
§ 405-14K(3), Steep slopes | Physical constraints | n/a | Development on ground which has an incline of 10% to 25% | Yes/Planning Board |
§ 405-15C, Waterfront Overlay, public access | Site constraints or incompatible uses | n/a | No public access on parcels outside of the SD-WMU | Yes/Planning Board |
| § 405-15D, Waterfront Overlay standards | Proposed outdoor storage consists of cultural exhibits/displays or maritime attractions that positively contribute to the waterfront pedestrian setting. | Exceptions to required screening of outdoor storage areas | n/a | No/Planning Administrator |
§ 405-16C, Parking requirements | Unique site or use circumstances | n/a | Exceptions to maximum parking limits | Yes/Planning Board |
§ 405-16E, parking access | Unique site circumstances (corner lot , or existing horseshoe driveway) | One additional curb cut permitted | n/a | No/Planning Administrator |
§ 405-16F, Parking lot landscape standards | Unique site or use circumstances | n/a | Nonpermeable streetscreens | Yes/Planning Board |
§ 405-17E, Pedestrian-oriented signs | Unique architectural qualities of a building, a building's historical significance, a building's civic or institutional use , civic prominence, or unique configuration of existing conditions of a building, as well as the quality of design, construction, and durability of the sign | Signage that does not fit the specific regulations of § 405-17 but meets the intent of this chapter | n/a | No/Planning Administrator |
§ 405-23B, right-of-way width | Physical constraints (existing buildings or natural features) | New street right-of-way width less than 45 feet | n/a | No/Planning Administrator |
§ 405-24C(1), minimum usable open space | Restrictive lot dimension or physical constraints (existing buildings or natural features) | n/a | Less than 10% usable open space provided | Yes/Planning Board |
§ 405-24C(6), steep slopes, floodplain or other natural areas | Providing improved, usable access to natural features | 50% maximum allocation of overall 10% minimum public usable open space | n/a | No/Planning Administrator |
§ 405-24C(2), usable open space in a CVP or WNP | Design constraint, such as restrictive lot dimension or physical constraints (existing buildings or natural features) | Backing buildings onto a shared usable open space | n/a | No/Planning Administrator |
§ 405-25C(1)(b), Transect Zone allocation | 80% of proposed housing units meet the requirements of § 405-19 for affordable housing | n/a | 10% to 40% of the CVP may be T5N | Yes/Planning Board |
§ 405-25C(2)(d), External connectivity | Physical conditions, such as highways, sensitive natural resources, or unusual topography provide no practical connection alternatives. | Proposed dead end must be detailed as a close (a small green area surrounded by a common driveway serving adjoining lots) and should provide pedestrian connectivity to the maximum extent practicable. | n/a | No/Planning Administrator |
§ 405-25C(2)(e), Block size | Topographic or site constraints | Blocks larger than set standards per transect | n/a | No/Planning Administrator |
Note: | ||||
Required findings shall be based on the intent of this chapter or non-self-imposed hardship. |