Design Standards
Angle of Parking (degrees) | One-Way Aisle (feet) | Two-Way Aisle (feet) | |
|---|---|---|---|
90 | 22 | 24 | |
60 | 18 | 24 | |
45 | 15 | 24 | |
30 | 12 | 24 | |
Parallel | 12 | 24 |
Total Parking Spaces | Minimum Required Handi- capped Parking Spaces | |
|---|---|---|
2 to 19 | 1 | |
20 to 49 | 2 | |
50 or more | 3, plus an additional 2% of the total parking spaces provided |
Use | Gross Square Footage at which First Off-Street Loading Berth is Required | Gross Square Footage at which Each Additional Loading Berth is Required | |
|---|---|---|---|
Manufacturing and warehouse | 5,000 | 40,000 | |
Storage | 10,000 | 25,000 | |
Commercial, wholesale | 10,000 | 40,000 | |
Commercial, retail | 10,000 | 20,000 | |
Service establishment | 10,000 | 40,000 | |
Restaurant | 10,000 | 25,000 | |
Office or bank | 10,000 | 100,000 | |
Hotel | 10,000 | 100,000 | |
School | 10,000 | 100,000 | |
Nursing home | 10,000 | 100,000 | |
Auditorium or arena | 10,000 | 100,000 |
Exhibit 1 Recommended Street Trees | |||
|---|---|---|---|
Botanical Name | Common Name | Size1 | |
Acer campestre | Hedge maple | Small | |
Acer rubrum | Red maple | Tall | |
Acer rubrum 'October Glory' | October Glory red maple | Tall | |
Acer saccharum | Sugar maple | Tall | |
Acer saccharum 'Green Mountain' | Green Mountain sugar maple | Tall | |
Carpinus caroliniana4 | American hornbeam | Small | |
Fraxinus americana4 | White ash | Tall | |
Fraxinus pennsylvanica lanceolata4 | Green ash | Tall | |
F.p. lanceolata 'Marshall's Seedless' | Marshall's seedless green ash | Tall | |
Gleditsia triacanthos inermis 'Shademaster' | Shademaster thornless honey locust | Tall | |
Ginkgo biloba (male only) | Gingko | Tall | |
Liquidambar styraciflua3, 4 | American sweetgum | Tall | |
Phellodendron amurense | Amur corktree | Medium | |
Quercus coccinea4 | Scarlet oak | Tall | |
Quercus palustris2, 4 | Pin oak | Tall | |
Quercus rubra4 | Red oak | Tall | |
Tilia cordata | Littleleaf linden | Medium | |
Tilia cordata 'Greenspire' | Greenspire littleleaf linden | Medium | |
Zelkova serrata 'Village Green' | Village Green zelkova | Tall | |
NOTES: | |
1Tall: greater than 40 feet; medium: 30 to 40 feet; small: less than 30 feet. | |
2Lower branches hang down. Should be used in areas where conflicts with pedestrians and vehicles will be at a minimum. | |
3Large seed pod may cause conflicts with pedestrians. Should not be used near sidewalks. | |
4Indigenous plant material. |
Road and Area Classification | Footcandle* (average minimum) | Uniformity Ratio (average minimum) | ||
|---|---|---|---|---|
Major | ||||
Commercial | 1.2 | 3:1 | ||
Intermediate | 0.9 | 3:1 | ||
Residential | 0.6 | 3.5:1 | ||
Collector | ||||
Commercial | 0.8 | 3:1 | ||
Intermediate | 0.6 | 3.5:1 | ||
Residential | 0.4 | 4:1 | ||
Local | ||||
Commercial | 0.6 | 6:1 | ||
Intermediate | 0.5 | 6:1 | ||
Residential | 0.3 | 6:1 | ||
NOTES: | ||
|---|---|---|
*The footcandle minimums proposed in the street illumination chart are offered as a guideline. Actual illumination should be designed based upon rural conditions, security, safety and other conditions specific to the area for which it is intended. | ||
Level of Activity | Footcandles (average minimum) | Uniformity Ratio (average minimum) | ||
|---|---|---|---|---|
Pedestrian walkways | 2.0 | 5:1 | ||
Bikeways | 0.6 | 4:1 | ||
Parking lots: | ||||
Residential, church, parks, etc. | 0.2 | 4:1 | ||
Office/commercial strip | 0.6 | 4:1 | ||
Shopping center/mall | 1.0 | 4:1 | ||
Attendant parking lot | 2.0 | 4:1 | ||
Traffic Lanes | ||||||||
|---|---|---|---|---|---|---|---|---|
Type of Street | Right-of-Way Width (feet) | Number | Width (feet) | Shoulder Width Within Gutters (feet) | Width (O.S.) of Gutters on Each Side1 (feet) | Width Between Gutters and Curbs (feet) | ||
Arterial | 80 | 2 and 2 | @ | 12 and 13 | — | 15 | 50 | |
Collector (primary) | 66 | 2 | @ | 12 | 8 | 13 | 40 | |
Collector (secondary) | 60 | 2 | @ | 11 | 7 | 12 | 36 | |
Local | 50 | 2 | @ | 152 | — | 10 | 30 | |
NOTES: | |
|---|---|
1Shall be grass-stabilized topsoil, minimum four inches thick. | |
2Area adjacent to curb available as parking area. |
Type of Street | Radius Requirement (feet) | |
|---|---|---|
Arterial | 40 | |
Collector | 35 | |
Local, commercial/industrial | 30 | |
Local, residential | 25 |
Grading Plan Checklist | |||
|---|---|---|---|
[ ] | 1. | Title block indicating the address of the site, lot and block numbers, name and address of the applicant and the title "Grading Plan." | |
[ ] | 2. | The plan must be signed and sealed (embossed) by a professional land surveyor, professional engineer or architect licensed in the State of New Jersey. The plan must also include the address of the person preparing the plan. | |
[ ] | 3. | The plan must be legibly drawn at a scale of one inch equals 30 feet, indicate a North arrow and refer to the vertical datum on which the plan is based. | |
[ ] | 4. | The plan must indicate all property lines, easements and required setback lines. All property lines must indicate bearings and dimensions, and the width of all easements must be shown on the plan. | |
[ ] | 5. | The distances between all existing and proposed structures and adjoining property lines must be indicated on the plan. | |
[ ] | 6. | The plan must indicate the right-of-way and cartway widths of all adjoining streets as well as the location of all existing and proposed curbs, sidewalks and driveway aprons along the entire frontage of the subject property. | |
[ ] | 7. | The plan must indicate existing and proposed contours at one-foot intervals a minimum of 25 feet over the entire lot area to be disturbed and 50 feet beyond the limit at grading. Spot elevations should also be provided at all inlets, catch basins, outfalls, culverts and other hydraulic structures. | |
[ ] | 8. | The plan must indicate existing and proposed spot elevations at all property corners. | |
[ ] | 9. | The plan must also indicate existing topography 50 feet beyond all property lines and spot elevations for all adjacent building corners. | |
[ ] | 10. | The plan must also indicate the location and dimensions of all structures and site improvements including buildings, sheds, decks, swimming pools, fences and any drainage facilities. | |
[ ] | 11. | The plan must indicate all stream encroachment, wetlands and wetland buffer lines and floodplains. | |
[ ] | 12. | The plan must indicate all trees over six inches in diameter, including type and condition and limits of clearing. | |
Additional Requirements for Grading Plans for New Structures and Additions | |||
[ ] | 13. | The plan must indicate the first-floor and basement elevations for all proposed structures. Spot elevations for all building corners must be indicated. If a basement is planned, certified soil boring(s) will be necessary showing soil types and the depth to seasonal high water table. | |
[ ] | 14. | The plan must indicate the location of all existing and proposed utility services, including vents and cleanouts. | |
Additional Requirements for Grading Plans for Swimming Pools | |||
[ ] | 15. | The plan must indicate swimming pool finished elevations, deck elevations, first-floor elevations for all dwellings and the type, height and location of fencing. | |
[ ] | 16. | The plan must indicate limits of land disturbances as well as cut/fill areas. | |
Design Standards
Angle of Parking (degrees) | One-Way Aisle (feet) | Two-Way Aisle (feet) | |
|---|---|---|---|
90 | 22 | 24 | |
60 | 18 | 24 | |
45 | 15 | 24 | |
30 | 12 | 24 | |
Parallel | 12 | 24 |
Total Parking Spaces | Minimum Required Handi- capped Parking Spaces | |
|---|---|---|
2 to 19 | 1 | |
20 to 49 | 2 | |
50 or more | 3, plus an additional 2% of the total parking spaces provided |
Use | Gross Square Footage at which First Off-Street Loading Berth is Required | Gross Square Footage at which Each Additional Loading Berth is Required | |
|---|---|---|---|
Manufacturing and warehouse | 5,000 | 40,000 | |
Storage | 10,000 | 25,000 | |
Commercial, wholesale | 10,000 | 40,000 | |
Commercial, retail | 10,000 | 20,000 | |
Service establishment | 10,000 | 40,000 | |
Restaurant | 10,000 | 25,000 | |
Office or bank | 10,000 | 100,000 | |
Hotel | 10,000 | 100,000 | |
School | 10,000 | 100,000 | |
Nursing home | 10,000 | 100,000 | |
Auditorium or arena | 10,000 | 100,000 |
Exhibit 1 Recommended Street Trees | |||
|---|---|---|---|
Botanical Name | Common Name | Size1 | |
Acer campestre | Hedge maple | Small | |
Acer rubrum | Red maple | Tall | |
Acer rubrum 'October Glory' | October Glory red maple | Tall | |
Acer saccharum | Sugar maple | Tall | |
Acer saccharum 'Green Mountain' | Green Mountain sugar maple | Tall | |
Carpinus caroliniana4 | American hornbeam | Small | |
Fraxinus americana4 | White ash | Tall | |
Fraxinus pennsylvanica lanceolata4 | Green ash | Tall | |
F.p. lanceolata 'Marshall's Seedless' | Marshall's seedless green ash | Tall | |
Gleditsia triacanthos inermis 'Shademaster' | Shademaster thornless honey locust | Tall | |
Ginkgo biloba (male only) | Gingko | Tall | |
Liquidambar styraciflua3, 4 | American sweetgum | Tall | |
Phellodendron amurense | Amur corktree | Medium | |
Quercus coccinea4 | Scarlet oak | Tall | |
Quercus palustris2, 4 | Pin oak | Tall | |
Quercus rubra4 | Red oak | Tall | |
Tilia cordata | Littleleaf linden | Medium | |
Tilia cordata 'Greenspire' | Greenspire littleleaf linden | Medium | |
Zelkova serrata 'Village Green' | Village Green zelkova | Tall | |
NOTES: | |
1Tall: greater than 40 feet; medium: 30 to 40 feet; small: less than 30 feet. | |
2Lower branches hang down. Should be used in areas where conflicts with pedestrians and vehicles will be at a minimum. | |
3Large seed pod may cause conflicts with pedestrians. Should not be used near sidewalks. | |
4Indigenous plant material. |
Road and Area Classification | Footcandle* (average minimum) | Uniformity Ratio (average minimum) | ||
|---|---|---|---|---|
Major | ||||
Commercial | 1.2 | 3:1 | ||
Intermediate | 0.9 | 3:1 | ||
Residential | 0.6 | 3.5:1 | ||
Collector | ||||
Commercial | 0.8 | 3:1 | ||
Intermediate | 0.6 | 3.5:1 | ||
Residential | 0.4 | 4:1 | ||
Local | ||||
Commercial | 0.6 | 6:1 | ||
Intermediate | 0.5 | 6:1 | ||
Residential | 0.3 | 6:1 | ||
NOTES: | ||
|---|---|---|
*The footcandle minimums proposed in the street illumination chart are offered as a guideline. Actual illumination should be designed based upon rural conditions, security, safety and other conditions specific to the area for which it is intended. | ||
Level of Activity | Footcandles (average minimum) | Uniformity Ratio (average minimum) | ||
|---|---|---|---|---|
Pedestrian walkways | 2.0 | 5:1 | ||
Bikeways | 0.6 | 4:1 | ||
Parking lots: | ||||
Residential, church, parks, etc. | 0.2 | 4:1 | ||
Office/commercial strip | 0.6 | 4:1 | ||
Shopping center/mall | 1.0 | 4:1 | ||
Attendant parking lot | 2.0 | 4:1 | ||
Traffic Lanes | ||||||||
|---|---|---|---|---|---|---|---|---|
Type of Street | Right-of-Way Width (feet) | Number | Width (feet) | Shoulder Width Within Gutters (feet) | Width (O.S.) of Gutters on Each Side1 (feet) | Width Between Gutters and Curbs (feet) | ||
Arterial | 80 | 2 and 2 | @ | 12 and 13 | — | 15 | 50 | |
Collector (primary) | 66 | 2 | @ | 12 | 8 | 13 | 40 | |
Collector (secondary) | 60 | 2 | @ | 11 | 7 | 12 | 36 | |
Local | 50 | 2 | @ | 152 | — | 10 | 30 | |
NOTES: | |
|---|---|
1Shall be grass-stabilized topsoil, minimum four inches thick. | |
2Area adjacent to curb available as parking area. |
Type of Street | Radius Requirement (feet) | |
|---|---|---|
Arterial | 40 | |
Collector | 35 | |
Local, commercial/industrial | 30 | |
Local, residential | 25 |
Grading Plan Checklist | |||
|---|---|---|---|
[ ] | 1. | Title block indicating the address of the site, lot and block numbers, name and address of the applicant and the title "Grading Plan." | |
[ ] | 2. | The plan must be signed and sealed (embossed) by a professional land surveyor, professional engineer or architect licensed in the State of New Jersey. The plan must also include the address of the person preparing the plan. | |
[ ] | 3. | The plan must be legibly drawn at a scale of one inch equals 30 feet, indicate a North arrow and refer to the vertical datum on which the plan is based. | |
[ ] | 4. | The plan must indicate all property lines, easements and required setback lines. All property lines must indicate bearings and dimensions, and the width of all easements must be shown on the plan. | |
[ ] | 5. | The distances between all existing and proposed structures and adjoining property lines must be indicated on the plan. | |
[ ] | 6. | The plan must indicate the right-of-way and cartway widths of all adjoining streets as well as the location of all existing and proposed curbs, sidewalks and driveway aprons along the entire frontage of the subject property. | |
[ ] | 7. | The plan must indicate existing and proposed contours at one-foot intervals a minimum of 25 feet over the entire lot area to be disturbed and 50 feet beyond the limit at grading. Spot elevations should also be provided at all inlets, catch basins, outfalls, culverts and other hydraulic structures. | |
[ ] | 8. | The plan must indicate existing and proposed spot elevations at all property corners. | |
[ ] | 9. | The plan must also indicate existing topography 50 feet beyond all property lines and spot elevations for all adjacent building corners. | |
[ ] | 10. | The plan must also indicate the location and dimensions of all structures and site improvements including buildings, sheds, decks, swimming pools, fences and any drainage facilities. | |
[ ] | 11. | The plan must indicate all stream encroachment, wetlands and wetland buffer lines and floodplains. | |
[ ] | 12. | The plan must indicate all trees over six inches in diameter, including type and condition and limits of clearing. | |
Additional Requirements for Grading Plans for New Structures and Additions | |||
[ ] | 13. | The plan must indicate the first-floor and basement elevations for all proposed structures. Spot elevations for all building corners must be indicated. If a basement is planned, certified soil boring(s) will be necessary showing soil types and the depth to seasonal high water table. | |
[ ] | 14. | The plan must indicate the location of all existing and proposed utility services, including vents and cleanouts. | |
Additional Requirements for Grading Plans for Swimming Pools | |||
[ ] | 15. | The plan must indicate swimming pool finished elevations, deck elevations, first-floor elevations for all dwellings and the type, height and location of fencing. | |
[ ] | 16. | The plan must indicate limits of land disturbances as well as cut/fill areas. | |