123 TOWN CENTER DESIGN STANDARDS
Table 19.123.050 Summary of key block frontage types. | ||
|---|---|---|
Permitted Frontage | Details | |
Storefront | ![]() | • No new ground-level parking adjacent to the street. • Special transparency, weather protection, and entry requirements. • Minimum commercial space height and depth. • No ground floor residential uses except for live/work units on select Storefront designated blocks where the storefront space meets height and depth standards. |
Secondary | ![]() Storefront or Landscape Frontages Allowed ![]() | • Ground-level parking must not be visible from the street. • Landscaping to soften facades of non-storefronts and buffer parking areas. • Minimum facade transparency requirements per use and setback. |
Landscape | ![]() | • Ground-level parking must not be visible from the street. • Landscaping to soften facades and buffer parking areas. • Minimum facade transparency requirements per use and setback. |
Figure 19.123.060 Map 1: Mountlake Terrace Town Center block frontage designations map. ![]() |
Table 19.123.070 Transparency standards. | ||
|---|---|---|
Transparency Area | ||
Storefront ![]() The transparency area is on the ground floor between 30" and 10' above sidewalk grade | Ground floor nonresidential and nonstorefront ![]() The transparency area is between 30" and 8' above grade | Residential buildings and residential portions of mixed-use buildings ![]() All vertical surfaces of the facade are used in the calculations |
Other Transparency Provisions | ||
Windows must be transparent Ground-level window area for storefronts and other nonresidential uses that is covered, frosted, or perforated in any manner that obscures visibility into the building must not count as transparent window area. Also, mirrored glass and highly reflective or darkly tinted windows must not be counted as transparent windows. | ![]() Covered windows | ![]() Perforated sign |
Display windows and parking garages Display windows may be used for up to 25% of nonresidential transparency requirements (except for ground-level storefront-designated block frontages on 57th Ave W and 233rd Street SW) provided they are at least 30" deep to allow changeable displays and the interior wall is nonstructural so it can be removed if the windows are not used for display. Tack-on display cases as shown in the far right example do not qualify as transparent window area. For parking garages (where allowed by block frontage standards), the left image illustrates how such a structure can meet (and not meet) the applicable transparency standards. | ![]() Integrated display windows | ![]() Tack-on display cases |
![]() Parking garage with windows | ![]() Parking garage without windows | |
Figure 19.123.080(A) Storefront vision and key standards. ![]() |
Table 19.123.080(B) Storefront block frontage standards. | ||
|---|---|---|
The ➲ symbol refers to departure opportunities in MTMC § 19.123.080(C). | ||
Element | Standards | Additional Provisions and Examples |
Ground-level | ||
Land use | MTMC § 19.50.040 sets forth ground-level uses permitted on storefront block frontages. | Lobbies and accessory uses associated with upper-floor professional-office and multi-household residential uses are allowed provided they are limited to 20% of all storefront block frontages and other storefront frontages. Exception: Such lobbies and accessory-uses associated with upper-floor professional-office and multi-household residential uses are not allowed on 57th Ave W and 233rd Street SW except where no other alternative is feasible. |
Floor to ceiling height | 13' minimum (applies to new buildings only). | Applies to the minimum retail space depth. |
Retail space depth | 50' minimum on 57th Ave W and 233rd Street SW and 30' minimum elsewhere (applies to new buildings only). ➲ | |
Building placement | Buildings must be placed at the back edge of the required sidewalk. Additional setbacks are allowed for a widened sidewalk or pedestrian-oriented space (MTMC § 19.123.190(D)). | ![]() Corner storefront building example. |
Building entrances | Primary building entrances must face the street. For corner buildings, primary entrances for ground-level building corner uses may face either street or the street corner. | |
Facade transparency (see MTMC § 19.123.070) | At least 70% of the transparency area. ➲ | |
Weather protection | Weather protection over the sidewalk is required along at least 75% of the storefront facade, and it must be a minimum of 6' deep and have 10' to 15' of vertical clearance. ➲ Weather protection must not interfere with street trees, street lights, street signs, or extend beyond the edge of the sidewalk. | ![]() |
Parking location | New ground-level (surface or structured) parking adjacent to the street is prohibited. Parking may be placed below, above, and/or behind storefronts. ➲ | |
SPECIAL FOR STOREFRONT BLOCK FRONTAGES ALONG 57TH AVENUE WEST | ||
Height Stepbacks | • Lower floors: Maximum building facade height of three stories. • Stepback minimum (after first, second or third floors): 10'. • Upper floors: Maximum building height within 60' of 57th Avenue W: Seven stories or 80' (whichever is less). • Maximum building height when more than 60' from 57th Avenue W: See MTMC § 19.50.050 for standards applicable to the subject zone. | ![]() |
Figure 19.123.090 Storefront corner block frontage example. ![]() |
Figure 19.123.100(A) Landscaped frontage vision and key standards. ![]() |
Table 19.123.100(B) Landscaped block frontage standards. | ||
|---|---|---|
The ➲ symbol refers to departure opportunities in MTMC § 19.123.100(C). | ||
Element | Standards | Additional Provisions and Examples |
Ground-level | ||
Land use | MTMC § 19.50.040 sets forth permitted land uses. | |
Building placement | 10' minimum setbacks are required, or greater where specified for the applicable zone in MTMC Title 19. ➲ | |
Building entrances | Building entries must face the street or a pedestrian-oriented space (MTMC § 19.123.190(D)) that is adjacent to the street. | ![]() Landscaped frontage example meeting setback, entry, weather protection, and transparency standards. |
Facade transparency (see MTMC § 19.123.070) | For buildings with ground-level nonresidential uses, at least 40% of the transparency area. ➲ For buildings with ground-level residential uses, at least 20% of the facade. ➲ | |
Weather protection | Weather protection at least 3' deep must be provided over individual residential and commercial tenant entries and at least 5' deep for shared residential and professional office entries. | |
Parking location | Ground-level parking must not be visible from the street. Where parking is integrated at or near the ground-level, it must be set back and completely screened by landscaped berms (upper right example). The lower right example illustrates a prohibited design. | ![]() ![]() |
Landscaping | All areas between the sidewalk and the building must be landscaped, except for pathways, porches, decks, and other areas meeting the definition of pedestrian-oriented space (MTMC § 19.123.190(D)). Landscaped areas must contain Types I, II, or IV landscaping (as defined in MTMC § 19.130.240) and may incorporate rain gardens and other forms of stormwater management. | ![]() |
Figure 19.123.110(A) Secondary frontage vision. | ||
|---|---|---|
Storefront Frontage ![]() | OR | Landscaped Frontage ![]() |
Table 19.123.110(B) Secondary block frontage standards. | ||
|---|---|---|
The ➲ symbol refers to departure opportunities in MTMC § 19.123.110(C). | ||
Element | Standards | Additional Provisions and Examples |
Building placement | Buildings may be placed up to the sidewalk edge provided they meet storefront block frontage standards in MTMC § 19.123.080 (this includes standards for ground-level, building placement, building entrances, facade transparency, and weather protection elements). | The minimum setback for buildings that do not meet applicable storefront block frontage standards is 10' or greater where specified for the applicable zone in MTMC Title 19. ➲ |
Facade transparency (see MTMC § 19.123.070) | Storefront buildings are subject to storefront block frontage transparency standards above. For other building frontages, transparent windows must be provided along at least 15% of the entire building facade, plus: • Buildings designed with ground-floor nonresidential uses within 10' of sidewalk, must feature at least 40% transparency within the transparency area. ➲ • Buildings designed with ground floor nonresidential uses within 20' of sidewalk, must feature at least 25% transparency within the transparency area. ➲ | |
Figure 19.123.110(C) Acceptable examples of possible setback departures. ![]() The apartment building (left image) includes a street setback of about six to eight feet and features a landscape planter, an elevated ground-level, and generous window transparency. The elevated stoop frontages (right image) is another acceptable reduced setback departure example. The combination of landscaping elements, facade transparency, low fencing, and facade materials and detailing help to create an effective transition between the public and private realm. |
Figure 19.123.120(A) Access corridor example illustrating shared pedestrian and vehicular access. ![]() |
Figure 19.123.120(B) Pedestrian access corridor examples. ![]() |
Figure 19.123.130 Clarifying block frontage standards on street corners. ![]() In the left example, the entrance may be placed along the storefront block frontage and/or directly on the corner. |
Figure 19.123.150(A) High visibility street corners. ![]() |
Figure 19.123.150(B) Acceptable high visibility street corner examples. ![]() All of the buildings above integrate distinctive articulation features (4). The bottom left example also integrates a corner plaza (1). |
Table 19.123.180(B) Minimum side and rear yard setbacks in the TC zones. | |
|---|---|
Min. Setback | Applicability/Standard |
0' | For windowless firewalls up to 6 stories in height. Provision does not apply to the development within or abutting the TC-R zone. All firewalls must meet the design provisions of MTMC § 19.123.270(D). |
5' | Minimum setback except: • Where zero setbacks are allowed (window-less firewalls as described above) • Where setbacks greater than 5' are required per provisions below |
>5' | In all sites abutting residential zones – see subsection (C) of this section. |
15' – 20' | When required per subsection (E) of this section for light and air access and privacy along side and rear property lines. |
Figure 19.123.180(C) Illustrating minimum side and rear yard setbacks to an abutting residential zoning district. ![]() |
Figure 19.123.180(D) Privacy standards for balconies within 15 feet of side or rear property lines. ![]() |
Figure 19.123.180(E) Light/air access and privacy standards for multifamily residential buildings along side and rear property lines. ![]() Note that the minimum setbacks noted above only apply to buildings (and portions thereof) featuring the stated characteristics. |
Figure 19.123.190(B)(1)(e) Rooftop deck examples. ![]() |
Figure 19.123.190(B)(2) Shared open space examples. ![]() The upper left example is a courtyard over a parking deck. Notice the transition elements between the courtyard and adjacent residential units. The upper right courtyard is shared by ground-level commercial uses and apartments above. |
![]() The left image above includes a covered gathering space with outdoor grills adjacent to a landscaped commons with a central pathway. The right image is an example of shared indoor recreation space. |
Figure 19.123.190(B)(2)(c) Shared open space – minimum widths when adjacent to building elevations containing windows of dwelling units whose only solar access is from the applicable building wall. | |
|---|---|
![]() | 20 feet minimum for such elevations up to three-stories tall. |
![]() | 25 feet minimum for such elevations four-stories tall. |
![]() | 30 feet minimum for such elevations five or more stories tall |
Figure 19.123.190(D) Example of site development integrating pedestrian-oriented space. ![]() |
Figure 19.123.190(D)(1) Example of a small pedestrian-oriented open space. ![]() |
Figure 19.123.210(D) Utility meter location and screening – good and bad examples. ![]() Place utility meters in less visible locations. The lower left example is successfully tucked away in a less visible location and screened by vegetation. The right image is poorly executed and would not be permitted in such visible locations (along the sidewalk). Such meters must be coordinated and better integrated with the architecture of the building. |
Figure 19.123.210(E) Examples of how to screen roof-mounted mechanical equipment ![]() The left illustration shows how rooftop mechanical equipment can be located and screened effectively. The right images shows effective location and screening, including side walls and a trellis to screen views from taller surrounding buildings. |
Figure 19.123.240(B) Tower design examples. ![]() Building 1 includes substantial podium with a curved tower that includes vertical articulation on one side. Building 2 includes a number of massing offsets with changes in fenestration that lend interest and depth to the façade. Building 3 also uses a number of massing offsets and material/fenestration changes to add visual interest. All buildings have a strong ground-level emphasis. |
Figure 19.123.240(C)(2) Facade articulation examples. ![]() Both buildings use a combination of window patterns, weather protection features, and vertical piers to effectively articulate the facade. |
![]() All three buildings above include a combination of window patterns and vertical building modulation. The left building uses recessed balconies, whereas the middle and right example use projecting balconies. The left and middle buildings also include weather protection features. |
Figure 19.123.240(D) Illustrating maximum facade length standards and good and bad examples. | |
|---|---|
![]() Less than 140' long: Meets standard | ![]() More than 140' long: Does not meet standard |
![]() Building incorporates a courtyard along the facade (technique #1 noted above) to effectively break it up into smaller components: Meets standard. | |
![]() The left building uses technique # 1 (vertical building modulation at least six-feet deep and 15 feet wide). The right building uses technique #2 (contrasting vertical modulated design component) together with different window fenestration designs on each side. Both examples are effective in breaking up the perceived scale of the building and adding visual interest. | |
Figure 19.123.240(E) Acceptable examples of roofline modulation. ![]() |
Figure 19.123.250(B)(1) Examples of decorative or specially designed windows and entries. ![]() Examples of decorative or specially designed windows and entries. Upper left (b) = openable storefront window. Center top (a) = transom windows. Upper right (e) = openable window with decorative details. Lower left (e) = decorative window shades. Bottom middle (d) = Decorative door. Bottom right (c) = recessed entry. |
Figure 19.123.250(B)(2) Examples of attached elements that enhance the visual intrigue of the building. ![]() Examples of elements attached to facades that enhance the visual intrigue of the building. Upper left (a) = retractable awning. Top center (d) = custom hanging bike rack and repair station integrated as a storefront design element. Upper right (b) = decorative lighting fixtures. Lower left and middle (a) = custom decorative canopy. Lower right (c) decorative tower. |
Figure 19.123.250(B)(3) Examples of building material details that enhance the visual intrigue of the building. ![]() Examples of decorative surface materials. The letters match the detail options in subsection (B)(3) of this section. |
Figure 19.123.250(C) Acceptable and unacceptable window design examples. ![]() | |
![]() | All but the lower middle image are recessed by at least two inches from the facade and add a sense of depth and richness to the facade. |
Figure 19.123.250(D) Examples of buildings employing confident and distinctive rooflines. ![]() |
![]() Building 1 uses a dramatic overhanging cornice at the corner. Building 2 uses a simple glass railing and an upper level building stepback. Building 3 uses a dramatic overhanging cornice line. Building 4 uses a “V” shaped roofline on its penthouse floor. Building 5 uses a highly articulated roofline with stepped overhangs. |
![]() Buildings 6 and 7 simply appear to end without any statement of confidence and do not meet the standard. |
Figure 19.123.250(E) Acceptable building entry examples. ![]() |
Figure 19.123.250(F) Flat rooftop design examples. ![]() |
![]() |
Figure 19.123.260(B)(1) Acceptable concrete block use/design. | |
|---|---|
![]() Building 1 uses smooth-faced CMU as a contrasting feature that helps to highlight the main building entry. The simple design helps to add emphasis to the doors, canopy and decorative sconce lights. | ![]() Building 2 illustrates an acceptable departure example, as CMU is used as the primary cladding material. Note the use of beige split facade CMUs above each of the awnings and coupled with the use of smooth-faced gray CMUs on the vertical columns (which employ black accent tiles for added interest). |
Figure 19.123.260(B)(2) Acceptable metal siding examples. ![]() Buildings 1 and 2 successfully use metal siding more as an accent element to help articulate the facade. Metal siding is the primary material for Buildings 3 and 4, both of which integrate subtle changes in color to go with articulation features and design details. |
Figure 19.123.260(B)(3) Acceptable and unacceptable EIFS examples. ![]() Buildings 1 and 2 mix EIFS with brick and other materials and integrate trim details around windows to add a sense of depth to the facade. Building 3 uses EIFS is between the window and sidewalk – this design is prohibited. Building 4 uses EIFS as the primary siding material, which is prohibited. |
Figure 19.123.260(B)(4) Acceptable and unacceptable cementitious wall board examples. ![]() The above building uses cementitious wall board in different textures and colors to help articulate the facade. The white color replicates the board and batten style in the left image and green color in the right image effectively replicates horizontal wood siding. |
![]() The wall board panels covering a large area in a single color would not meet the purpose of the standards. The right image is a better example and combines larger panels (dark maroon color) with horizontal wall board siding (beige color) as effective articulation features. |
Figure 19.123.270(B) Blank wall definition. ![]() |
Figure 19.123.270(C) Blank wall treatment examples. ![]() Buildings 1 – 3 feature acceptable treatments including a combination of high quality materials and landscaping (1), decorative lighting/sculptural element (2), and decorative artwork. The display cases in Building 4 don't meet the 16" depth requirement, nor do they meet the purpose of the standards. |
Figure 19.123.270(D) Acceptable firewall design where visible to the public. ![]() The left images uses a combination of paint bands and ivy to enhance the appearance of this large exposed firewall. The building in the right image uses simple scoring patterns and change in materials and color on part of the top floor to add visual interest. |
![]() | Plain gray concrete block firewalls such as this are not allowed when visible from the street. |