Zoneomics Logo
search icon

Redmond City Zoning Code

ARTICLE III

Design Standards, §§ 21.58.0010—21.62.030

21.60 Repealed

(Ord. 2614; Ord. 2753; Ord. 2803; Ord. 3083; Ord. 3186)

21.58.0010 Purpose.

A. Purpose.

1. Establish measurable design standards for site design, circulation, building design, and landscape design to guide preparation and review of all applicable development applications;

2. Ensure that development adheres to the desired form of community design in Redmond as expressed by goals, policies, plans, and regulations of the Redmond Comprehensive Plan and the Zoning Code while providing for creativity, flexibility, and alternative pathways for compliance;

3. Supplement land use regulations which encourage and promote public health and safety of the Redmond community;

4. Promote sustainable and resilient development projects that will provide long-term community benefits, have a high environmental and visual quality, and coordinate with the City’s Green Building Program;

5. Ensure that new buildings are of a character and scale that is appropriate to their use and to the site and consider the needs of community members of all ages, genders, cultures, and abilities;

6. Encourage building variety while providing for designs that reflect the distinctive local character, the context of the site, and the community’s diversity, historical character, and natural features; and

7. Support decision making by the Administrator, Technical Committee, Hearing Examiner, and City Council in the review of development applications. (Ord. 3220)

21.58.0020 Scope and Authority.

A. Scope. RZC Chapter 21.58 establishes design standards for construction in Redmond based on the vision adopted in the Redmond Comprehensive Plan. Design standards are focused on equity and inclusion, sustainability, and resiliency as well as public health and welfare, quality of life, and safety. Standards are intended to achieve specific identified objectives with alternative design compliance opportunities to achieve identified objectives where appropriate, as indicated in RZC Chapter 21.58.

B. Authority. See RZC 21.76.020.E, Review Procedures, for design review.

C. Compliance with Design Standards. Decisions on applications requiring design review will be made as follows:

1. Each design standard section has a purpose statement followed by design standards.

a. Purpose statements describe the City’s objectives for each design element and are the requirements that each project must meet.

b. The design criteria that follow the purpose statements are objective ways to achieve the design purpose. Each criterion is meant to indicate the preferred condition, and the criteria together provide a common theme that illustrates the purpose statement.

c. Graphics are also provided to clarify the concepts behind the purpose statements and design criteria.

d. If there is a discrepancy between the text and the illustrations, the text will prevail.

2. All applications that require design review must comply with the purpose statements for each applicable design standard element.

a. If “shall,” “must,” or “will” are used in the design criterion, all applications must comply with that specific design criterion if it applies to the application unless the applicant demonstrates that an alternate design provides an equal or greater level of achieving the purpose of the section and the purpose of the design category.

b. The applicant has the burden of proof and persuasion to demonstrate that the application complies with the purpose statements.

i. The applicant must demonstrate to the satisfaction of the Administrator that the application complies with the applicable purpose statements and the design criteria that use the word “shall,” “must,” or “will.”

ii. If “should” is used in the design criterion, there is a general expectation that utilizing the criterion will assist in achieving the purpose statement; however, there is a recognition that other solutions may be proposed that are equally effective.

3. Each design standard section also includes a statement that describes if an alternative design compliance pathway is available and under what circumstances the design standards may vary.

D. Conflicts with Site Requirements. These design standards supplement the development standards and site requirements of each zone. The design standards must be implemented in a manner that allows developments of the type and scale set by the Comprehensive Plan and development regulations while achieving the design purposes. Where the provisions of RZC 21.58.0020 conflict with the provisions of the zone, the provisions of the zone will control. (Ord. 3220)

21.58.0100 Design Standards Applicability and Alternatives.

A. Purpose.

1. To provide a variety of options for development on a parcel while ensuring that all new development is human scaled and creates a sense of place.

2. To provide flexibility to accommodate a variety of building types and scales, as well as diverse housing types and commercial spaces, that can accommodate growth in alignment with the Redmond Comprehensive Plan.

B. Building Forms.

1. Relationship to Zoning District Development Standards.

a. Maximum height varies by zone and if the parcel is within a TOD focus area (see RZC Article I).

b. Applicability of the design standards in RZC Chapter 21.58 will vary by building height, building form, and in some instances by use. See applicability statements in each section of RZC Chapter 21.58.

2. Building Typologies.

a. Standard buildings: buildings up to 85 feet in height.

b. Mass timber buildings: buildings where the primary load-bearing structure is made of either solid or engineered wood. See RZC 21.58.5100 for mass timber standards and alternative design compliance.

c. Towers: buildings over 85 feet in height. See RZC 21.58.5200 for tower standards and alternative design compliance. For portions of the tower under 85 feet in height the standard building regulations, options, and alternatives apply.

d. Small building option: buildings limited in height may choose a simplified design standard pathway. See RZC 21.58.0100.C.

C. Small Building Option.

1. Purpose. This alternative design compliance option has been provided as a minimal design approach for smaller buildings, such as small-lot infill projects, or for smaller buildings in a multi-building development, or other small projects. This approach allows for waivers of some design requirements when providing minimum facade enhancements and ornamentation, such as architecturally integrated artwork.

2. Applicability. The small building alternative is limited by building height according to Table 21.58.0100.C.1. Buildings utilizing this option are not eligible for height increases using any program that offers additional building height.

Table 21.58.0100.C.1. Small Building Option Eligibility

Zoning District

Max Building Height

Downtown Edge, Marymoor Edge, Overlake Urban Multifamily, Corridor Mixed-Use

45 ft.

Downtown Core, Marymoor Core, Overlake Village, Overlake Business and Advanced Technology, or Urban Mixed-Use zones

60 ft.

3. Minimum Design Standards.

a. A vertical break in building material, texture, or scale at the lesser of 120 feet or 66 percent of the building width at the street frontage is required. Buildings less than 40 feet in width at the street frontage are exempt.

b. Facade.

i. Balconies: Use recessed or enclosed balconies. Avoid Juliet and suspended balconies.

ii. Weather protection: Continuous, well-blended and contextual with the building.

iii. Fenestration: Deep-set, multi-paned large windows that give dimension, transparency and natural light to residents. Avoid contrast with facade material. For example, avoid white vinyl windows on a dark facade.

c. Fifteen percent minimum ornamentation of facade required. See RZC 21.58.3700, Materials and Ornamentation. (Ord. 3220)

21.58.0300 Alternative Design Compliance.

A. Purpose. The alternative design compliance option allows and encourages flexibility in the design standards in order to promote creativity in site and building design, encourage distinctive design elements, and allow for unique, iconic buildings in centers. ADC options are encouraged to be considered as a part of project early design decision making phases and are intended to be utilized regularly.

B. References.

1. Alternative design compliance is not the same as administrative design flexibility. See RZC 21.76.070.C, Administrative Design Flexibility, for site design and development standards flexibility.

2. See RZC Chapter 21.16 for exemptions to setbacks and building heights, including access to rooftop amenities.

3. See zoning development standards tables in RZC Article I for additional flexibility in building height.

4. For development agreement alternative pathway, see RZC 21.76.070.L.

C. Applicability.

1. All proposals requiring design review may seek approval of alternative design compliance (ADC) from the Administrator where allowed in RZC Article III, subject to ADC requirements within each section.

2. All deviations, major and minor, must comply with the listed criteria of RZC Chapter 21.58.

D. Submittal Requirements. The review of ADC requests will occur as part of the standard design review process and is not a separate review process (see RZC 21.76.020.E).

1. The applicant seeking alternative design compliance from the design standards in RZC Article III must demonstrate, in writing, indicating the following:

a. How the project meets the listed criteria and is code compliant;

b. How the alternatives(s) requested deviate from the applicable standard requirement(s) and option(s) available; and

c. Indicating the improvements gained by application of the alternative(s).

2. Applicant must submit conceptual architectural sketches showing variation request(s).

E. Review Process.

1. When ADC is requested, a preapplication conference is recommended.

2. If the Administrator or their assigned designee makes a recommendation to vary the design requirements, it will be based on the following:

a. The alternative meets the purpose of the standard and all applicable ADC conditions as described in the relevant section(s) of RZC Chapter 21.58;

b. Permitting a variation will not be materially detrimental to the public welfare or injurious to the property or improvements in the area;

c. Permitting a variation will not be contrary to the objectives of the design standards or the site requirements and development standards of the relevant zoning district(s);

d. Permitting a variation in design better meets the goal and policies of the Comprehensive Plan and neighborhood goals and policies;

e. Permitting a variation in design results in a superior design in terms of architecture, building materials, site design, landscaping, and open space;

f. The variation protects the integrity of a historic landmark or the historic design subarea; and

g. Granting of the variation is consistent with the Shoreline Master Program, if applicable. (Ord. 3220)

21.58.1000 Context Sensitive Design.

A. Purpose. The purpose of design context is to provide contextual references that can be used to encourage creative and distinctive designs for new development and redevelopment projects while avoiding sameness in design; and to create contexts that capture the community visions and values as reflected in the Comprehensive Plan and Redmond Zoning Code. Attentiveness to design context ensures that:

1. Buildings relate to their individual sites, general locations, and to the zone and block.

2. Buildings are designed for the local climate and year-round environment.

3. Building proportions prioritize pedestrian orientation, the human scale, and comfort for building users.

4. The building’s scale and design harmonize with other buildings and features along the street upon which it is located.

5. The building’s mass and composition enhance and harmonize with neighboring structures while providing a distinctive street presence.

6. Sites and their structures contribute to a distinctive street presence. (Ord. 3220)

21.58.1100 Relationship to Adjacent Properties.

A. Purpose. The purpose of design relationship to adjacent properties is to promote visual distinction of the City, its neighborhoods, districts, and individual sites; and to create contexts that capture the community visions and values as reflected in the Comprehensive Plan and Redmond Zoning Code.

1. Promote functional and visual compatibility along with cultural creativity and innovation between adjacent neighborhoods, districts, land uses, and individual sites.

2. Encourage building designs that use natural, historic, traditional, or cultural references to create elements that link new development projects to the respective neighborhood and the community.

3. Adjacent historic and cultural elements support context. Historic landmarks and the section of Leary Way framed by older historic structures have been identified as contributing to the historic character of the City. In addition, Redmond’s native peoples and Redmond’s heritage define the more general historic and cultural context of the City. RZC 21.58.1100 regulates design of designated landmarks and historic districts as allowed in RCW 36.70A.630 or its successor.

B. Applicability. RZC 21.58.1100 applies citywide to all new development of sites and structures.

C. References.

1. See RZC Chapter 21.05, Special Districts and Overlays.

2. See RZC 21.36.400, Design Requirements.

D. Design Standards.

1. Site Context. Development of the site and structures must demonstrate a relationship between the proposed site and structures and the existing site, general location, zone, and block.

a. New development projects must coordinate with surrounding sites and developments within a two-block radius of the project limits through the following design techniques:

i. Include a minimum of two coordinating building design elements (e.g. materials, colors, entryway designs, projections, roofline treatments);

ii. Provide a minimum of two coordinating site design elements (e.g. parks, open space, landscaping, paving treatments, wayfinding); and

b. Connecting open space with adjacent open space and utilizing common design elements so the spaces feel to the user as one continuous space (see RZC 21.36.400.B.4) counts as one of the required site design elements under RZC 21.58.1100.

Figure 21.58.1100.D.1. Example of Connecting Adjacent Open Space with Common Design Elements

2. Distinctive Street Presence.

a. Development of the site and structures’ mass and composition must provide:

i. A minimum of one site design element that is unique to the project limits in comparison to adjacent or abutting parcels.

ii. A minimum of four building design elements that are unique to the project limit in comparison to buildings located within adjacent or abutting parcels. The unique building design elements must include at least two of the following:

A. Primary color and secondary material;

B. Building silhouette;

C. Design symmetry;

D. Vegetated building surfaces;

E. Resilient or ecological material; or

F. Innovative, artistic features representative of the neighborhood, zoning, or cultural district’s vision as adopted in the Redmond Comprehensive Plan.

b. Avoid using more than two colors from adjacent buildings.

3. Historic Structures and Sites.

a. New development projects must design the site and structures to complement abutting designated historic landmark properties and structures, as listed in RZC Appendix 5, Redmond Heritage Resource Register.

i. New development must avoid obscuring the features of significance of the designated historic landmark, as identified in the approved Designation Report – Findings of Fact and Decision for the historic landmark, from the public when viewed from the pedestrian realm, park, or trail. Designation reports are kept on file at the Development Service Center.

ii. Views from the new development project may include views of significant features of the historic landmark.

b. Old Town.

i. New development projects within Old Town (see Figure 21.58.1100.D.2) must use design elements that reinforce historic-period properties and structures.

Figure 21.58.1100.D.2. Map of Old Town Redmond

ii. Developments must repeat a minimum of one exterior color or design element from a historic property within two blocks of the project limits.

E. Alternative design compliance may be allowed if the alternative meets or exceeds the purpose of design relationship to adjacent properties. Developments within cultural districts and iconic buildings in centers intended as landmark placemaking buildings may utilize the alternative design compliance for requirements for coordinating building design elements with surrounding properties. (Ord. 3220)

21.58.1200 Ridgelines and Hill Tops.

A. Purpose. The purpose of design context with ridgelines and hill tops is to minimize visual and environmental impacts on distinctive landforms throughout the City.

1. Reduce natural hazards and impacts on the natural environment and to minimize the visual impact of development on hillsides.

2. Respect natural landforms and to use them to provide definition between various parts of the community and to provide project identity.

3. Minimize visual and environmental impacts on ridgelines and hill tops.

B. Applicability.

1. RZC 21.58.1200 applies citywide to all new development of sites and structures.

2. Exemption. Development within centers is exempt from design standards in RZC 21.58.1200.

C. References. See RZC 21.64.060, Geologically Hazardous Areas.

D. Design Standards. Development on hillsides should minimize visual and environmental impacts, as shown in Figure 21.58.1200.D.

1. Locate structures to ensure the tops of structures are located below prominent ridgelines or the trees/vegetation along ridgelines.

2. Retain existing wind-resilient trees/vegetation along ridgelines.

Figure 21.58.1200.D. Developments Along Ridgelines and Hilltops

E. Alternative design compliance is not allowed for RZC 21.58.1200, Ridgelines and Hill Tops. (Ord. 3220)

21.58.1300 Stream and Wetland Buffers.

Reserved. (Ord. 3220)

21.58.1400 Shorelines and Parks.

A. Purpose. The purpose of context sensitive design with shorelines and parks is to protect and enhance these natural resources and city assets for access and enjoyment by the community.

B. Applicability.

1. RZC 21.58.1400 applies citywide to all new development, including the site and structures.

2. Exemption. Single-family and middle housing development are exempt from design standards in RZC 21.58.1400.

C. References. See RZC Chapter 21.68, Shoreline Master Program.

D. Design Standards.

1. Building Orientation and Access.

a. Developments adjacent to the Sammamish River Trail between the 8300 block and the Redmond Central Connector must provide a pathway or walkway between the development and the Sammamish River Trail, unless modified through an approved development agreement where alternative access is provided.

b. Developments must provide pedestrian and bicycle access through the site to these features, when adjoining the Sammamish River, Bear Creek, and other shorelines, as well as their associated parklands, trails, and pathways.

c. Developments must provide building entrances, balconies, or other such building features or site features on the facade fronting waterways or parks.

d. Buildings must incorporate a minimum of two architectural features on the facades facing the trails and pathways such as, but not limited to:

i. Glazing for visibility of the trails and pathways by building users, refer to Table 21.58.3610.D.3, Facade Transparency;

ii. Public art installation, excluding public art involving lighting when the facade is oriented toward a shoreline;

iii. Wayfinding treatment such as signage on the facade; or

iv. Interpretive signage regarding natural or historic elements occurring within one-half mile of the project limits.

2. Site and Building Design.

a. New development projects must include the following site design elements when the project limits adjoin shorelines or parks:

i. Nonmotorized access where the site abuts the shoreline or park; and

ii. Landscaping, plazas, and other pedestrian features incorporated into the design of the nonmotorized access.

b. Development of parking facilities next to parks and waterways must be screened by natural-looking landscape buffers with tall trees and understory vegetation between the parking facilities and the parks or shoreline.

i. Buffering must be located between the parking facility and the park or shoreline.

ii. Landscape buffer must be at least 30 feet wide.

c. When surface stormwater facilities are placed near the shorelines and parks, they must not create a barrier between the use and the shoreline or park.

3. Multiple Building Design. Buildings in groups within new development projects must be related. Repeat two or more styles, materials, roof shapes, or other distinctive architectural elements.

E. Alternative design compliance may be allowed if the alternative meets or exceeds the purpose of context sensitive design with shorelines and parks. (Ord. 3220)

21.58.1500 Redmond Central Connector.

A. Purpose. The purpose of RZC 21.58.1500 is to ensure that buildings and uses along the Redmond Central Connector (RCC) in Downtown Redmond are designed to engage with and provide access to the RCC, while also ensuring that uses do not hamper rail use in the future if the rail line is reactivated.

B. Applicability.

1. RZC 21.58.1500 applies to all new development abutting the RCC in Downtown Redmond.

2. Exemption. In view of the elevated grade and steep side slopes of the portion of the RCC in the vicinity of the trestle crossing of Redmond Way and the Sammamish River, the provisions of RZC 21.58.1500 do not apply to the properties within the portions of the Downtown Core zone that adjoin the RCC and are at or west of the crossing over Redmond Way.

C. Design Standards.

1. Building Orientation and Access. Buildings along the RCC should orient to the RCC as well as to the streets, and should include storefronts and entrances to, and through, the building from the RCC.

2. Site and Building Design.

a. Where a site adjoins the RCC, the development must include a minimum of two site design elements that reinforce the RCC such as but not limited to connecting landscaping, plazas, and other pedestrian features.

b. Parking garages facing the RCC must be designed with ornamental grille work in garage openings or other architectural features on solid walls to ensure that blank, sterile walls do not loom over the RCC.

c. Architectural detailing must be included on all sides of the buildings, including the facades visible from the RCC.

d. All ground floor space constructed adjoining the RCC, including garage floors at the street grade, must have a minimum ceiling height of at least 10 feet. Ground floor garage space constructed facing and abutting the RCC that is later converted to commercial/retail space facing/fronting the RCC with entry doors and storefronts is exempt from providing required parking for the space converted from parking stalls to commercial space and is exempt from replacing any parking stalls eliminated by the conversion of the ground floor parking stalls to retail/commercial space.

D. Alternative design compliance may be allowed if the alternative meets or exceeds the purpose of design along the Redmond Central Connector. (Ord. 3220)

21.58.1600 High Traffic Corridors, BP, MP, and I Zones.

A. Purpose. The purpose of RZC 21.58.1600 is to promote healthier living environments by minimizing noise and air pollution.

1. Decrease impacts of sound and air pollution.

2. Reduce allergens, improve air quality, and reduce exposure to particulate air pollution.

B. Applicability. RZC 21.58.1600 applies citywide to all new development with project limits adjacent to freeways, principal or minor arterials, or are adjacent to BP, MP, or I zones.

C. Design Standards.

1. Utilize the following techniques to minimize the potential negative impacts to residents living adjacent to manufacturing uses or uses with similar impacts:

a. Screening. New residential uses must provide Type 1 screening as required in Table 21.32.120, Types of Planting.

b. Building Orientation. Orient multifamily structures to protect sensitive areas such as bedrooms from noise and light impacts.

c. Nonmotorized Circulation and Open Space. Design nonmotorized circulation and open space areas for pedestrians and bicyclists that minimizes noise and light impacts from adjacent uses.

2. Comply with applicable overlay requirements in RZC Chapter 21.05, Special Districts and Overlays, and RZC 21.16.600, Special Requirements.

D. Alternative design compliance may be allowed for this standard if the alternative meets the purpose of RZC 21.58.1600 and does not propose housing units within 60 feet of a property line abutting freeways, principal or minor arterials, BP, MP, or I zones. (Ord. 3220)

21.58.2000 Universal Design.

A. Purpose. The purpose of RZC 21.58.2000 is to make the community more accessible and implement the Redmond Comprehensive Plan goals for equity and inclusion.

1. To implement the Redmond Comprehensive Plan equity and inclusion goals and objectives through the design of spaces and environments that are usable by all people to the greatest extent possible without the need for excessive adaptation.

2. To include in the design process consideration for the needs of all community members regardless of their age, gender, language, or ability.

B. Applicability. Universal design features in RZC Appendix 12 are highly encouraged citywide for all new development and major redevelopments.

C. References.

1. See RZC Chapter 21.55, Development Incentive Program.

2. See RZC Appendix 12, Universal Design Incentives Standards.

3. See Redmond Comprehensive Plan, Community Development and Design chapter.

D. Design Standards.

1. Incentives are provided in RZC Chapter 21.55 for universal design checklists and specific techniques. The checklists provided in RZC Appendix 12 provide the requirements to qualify for the available incentives.

2. Where conflicts with state and federal codes occur, the most restrictive applies. (Ord. 3220)

21.58.2100 Inclusive Neighborhood Standards.

A. Purpose. The purpose of RZC 21.58.2100 is to implement the Redmond Comprehensive Plan goals for inclusive neighborhoods.

B. Applicability. All new development within inclusive neighborhood boundaries as defined in RZC 21.05.230.

C. Design Standards.

1. To implement the Redmond Comprehensive Plan goals for an inclusive neighborhood (see Figure 21.05.230.B), mixed-use and nonresidential development shall provide at minimum the following features:

a. Adult changing room (see Appendix 12, Section 12.4.A);

b. Mobility device charging area (see Appendix 12, Section 12.4.C);

c. Automatic doors (see Appendix 12, Section 12.4.B).

2. All development must provide the elements indicated as mandatory for inclusive neighborhoods in RZC Appendix 12, Section 12.3, as applicable.

3. All universal design features implemented as part of the inclusive neighborhood standards may be utilized towards achieving one or more incentive (see RZC Chapter 21.55).

D. Alternative Design Compliance may be allowed if the alternative provides the same or increased accessibility, if site conditions limit implementation, or if state and federal code conflicts occur. (Ord. 3220)

21.58.3000 Building Standards.

A. Purpose. Building standards provide minimum requirements for public safety and quality of life and implement the vision and goals for community development and design adopted in the Redmond Comprehensive Plan. (Ord. 3220)

21.58.3100 Street Wall Breaks and Stepbacks.

A. Purpose. The purpose of RZC 21.58.3100 is to create a vibrant, pedestrian-friendly streetscape with clear visual breaks to reduce bulk and improve solar access.

1. Add visual interest to the street that reflects the community visions and values for centers and mixed-use zones as reflected in the Comprehensive Plan and Redmond Zoning Code.

2. Promote harmony with other buildings and features along the street, its neighborhoods, districts, and individual site.

3. Create an appropriate scale street wall for pedestrians.

4. Establish a sufficient visual break between buildings or building elements within a single frontage, so as to ensure that they read independently.

5. Minimize the impression of building bulk to pedestrians.

a. Physical breaks minimize the appearance of building bulk.

b. Material changes minimize the appearance of building bulk.

6. Reduce shadows and increase solar access.

B. Applicability.

1. RZC 21.58.3100 applies to all new developments in centers and Urban Mixed-Use zone where the building is greater than 45 feet in height.

2. Exemptions. The building is exempt from stepback standards in RZC 21.58.3100 if any of the following site conditions apply:

a. Where building frontage is on a street with a ROW of 85 feet or greater. RZC 21.58.5200’s tower standards apply, if applicable.

b. Where a linear open space, trail, or tree preservation area exists between the edge of the street and the front of the building and is at least 20 feet wide.

c. Where site typography raises the first-floor building entry greater than 10 feet above the level of the street.

C. Design Standards.

1. The street wall elements of the building, such as building entrances, plinth, belt course, and exterior patterns should be designed to contribute to the pedestrian realm, including reducing apparent mass and bulk, and avoiding long, continuous flat facades, as shown in Figure 21.58.3100.C.2.

2. Building Width. Maximum building width without a break or material change is 120 feet per Figure 21.58.3100.C.2.

Figure 21.58.3100.C.2. Reducing Apparent Mass and Bulk with Building Break

3. Interior Facade Modulation. Facades facing interior property lines and interior portions of the lot that are visible from the street must be modulated approximately every 40 feet or every two units, whichever is greater, by one or more articulation methods (e.g., building break). Architecturally integrated public art, integrated photovoltaic, material change, or green wall may be used as an alternative to interior modulation.

4. Building Stepbacks. Create human scale at street level by using noticeable stepbacks in the building design and utilizing those stepbacks for amenities and vegetation. See RZC Chapter 21.55 for related incentives.

Figure 21.58.3100.C.4
Building Stepback Standards by Development Type

Table 21.58.3100.C.4. Building Step Back Standards by Development Type

Standards

Standard

Podium

Tower

Mass Timber Construction

Small Building Alternative Design Standards Option

Step back varies based on the composition of the building and its contextual surroundings or building construction method.

Stepback locations

Stepbacks must be included on street-facing facades

Stepbacks must be included on a minimum of 60% street-facing facades

Stepbacks must be included on street-facing facades

See RZC 21.58.5200 for tower standards

Stepbacks must be included on a minimum of 60% street-facing facades

See ornamentation alternative

Stepback begins (story)

After 2nd or 3rd story for buildings with 6 or more stories

After 3rd or 4th story

Alternatively stepback at podium top

After 3rd or 4th story for first stepback

2nd stepback required between 6th and 8th story for buildings with 12 or more stories

Exception if meets tower at grade standards in RZC 21.58.5200, Towers

After 2nd, 3rd or 4th story

Exception if meets tower at grade standards in RZC 21.58.5200, Towers

Minimum depth of stepback, measured from the building edge at the street frontage

15 ft. min.

15 ft. min. at first stepback

20 ft. min. at first stepback

10 ft. min. for other stepbacks

15 ft. min.

10 ft. min.

Minimum depth of stepback if podium top amenities and vegetation are provided

10 ft. min.

15 ft. min. at first stepback

15 ft. min. at first stepback

10 ft. min. for other stepbacks

15 ft. min.

10 ft. min.

Stepback variations

A maximum of 25% of the building frontage may vary from stepback requirements.

Minimum stepback may be averaged where no portion of the stepback is less than 10 ft. in depth.

Ornamentation alternative to stepback

Buildings that include ornamentation over at least 15 percent of the street wall facade facing public streets are exempt from stepback requirements. See RZC 21.58.3860 Details and Ornamentation.

Podium and rooftop amenities

Incentives are available for podium and rooftop amenities. See RZC Chapter 21.55, Development Incentive Program.

Podium top amenities that provide PEAS are encouraged, with a minimum depth of 20 ft. preferred.

Direct access to podium top amenities from the sidewalk is encouraged when facing a park or trail are encouraged.

Additional considerations

In Overlake, maximum building height must not exceed 70 feet within 50 feet of the west edge of the right-of-way of 156th Avenue NE or within 50 feet of the west edge of the right-of-way of Bel-Red Road, north of NE 24th Street.

D. Alternative design compliance may be allowed if the alternative meets or exceeds the purpose of the street wall breaks and stepbacks. (Ord. 3220)

21.58.3200 Rooflines.

A. Purpose. The purpose of RZC 21.58.3200 is to create a visually interesting skyline and align development with city priorities.

1. To incorporate design elements into roofline and promote visual interest to enhance skyline.

2. To reduce the feeling of bulk.

3. To support city priorities of environmental sustainability, climate resiliency, and habitat connectivity.

B. Applicability.

1. RZC 21.58.3200 applies to all new development in centers and the Urban Mixed-Use zone.

2. Exemption. Mass timber buildings with exposed wood elements on building exterior are exempt from roofline modulations.

C. References.

1. See RZC 21.58.5200, Towers.

2. See RZC 21.58.5500, Screening for Mechanical Instruments.

3. See RZC Chapter 21.55 for incentives for activation of podium tops and rooftops and pollinator habitats.

4. See City of Redmond Climate Resiliency and Sustainability Vegetation Management Plan for sustainable vegetation management.

D. Design Standards.

1. New development projects must create a varied and visually distinctive roof form.

a. The width of any continuous roofline treatment must not extend more than 120 feet or a maximum of 30 percent of the linear extent of frontage facing a public right-of-way, whichever is less.

b. Use features such as but not limited to prominent cornice or fascia, stepped roofs, emphasized dormers, chimneys, gables, or an articulated roofline to create variety and visual distinction.

2. Minimum Modulation. The height of the roofline must change at least five feet per modulation.

3. Vegetation Alternative. New development projects may provide vegetation at rooflines as an alternative to roofline modulation. The use of vegetation for blank wall treatment and for roofline mitigation must meet the following design standards:

a. Plants must be selected from the City of Redmond Climate Resiliency and Sustainability Vegetation Management Plan.

b. Plants used for roofline mitigation must achieve 40 percent canopy cover of the mitigation area at maturity.

c. Maintenance. A maintenance plan for resiliency and longevity must be included as part of project submittal.

4. FAR Reallocation.

a. The maximum building height on a site may be exceeded by a maximum of one story when building height reductions are required at building edges, along a street, public park, or public trail, to accomplish the following objectives:

i. Facade modulation meeting minimum dimensions; or

ii. Stepped building height to reduce the apparent height of the building; or

iii. Corner building design to encourage pedestrian activity through improvements along the streetscape.

iv. The added area must not exceed the floor area removed or omitted to meet the above objectives and will not be considered additional FAR.

E. Alternative design compliance may be allowed for designs that meet or exceed the purpose of roofline modulation. (Ord. 3220)

21.58.3300 Enclosed Courtyards.

A. Purpose. The purpose of RZC 21.58.3300 is to maintain adequate natural light for residential dwellings and landscaping.

B. References.

1. See also RZC 21.58.6030, Minimum Residential Courtyard Dimensions.

2. Buildings greater than 85 feet must also comply with the tower regulations in RZC 21.58.5200.

C. Applicability. RZC 21.58.3300 applies citywide to multifamily or mixed-use residential structures over 70 feet in height.

D. Design Standards.

1. Enclosed courtyards will not be permitted for structures over 70 feet in height, except when:

a. The floorplates for floors above 70 feet do not exceed 50 percent of the structure’s floor plate at the ground level; or

b. The courtyard, due to its size and orientation, is designed to allow natural light to light all areas of the courtyard during various times of the day, such that no area of the courtyard is perpetually in shadow during all daylight hours;

c. The interior courtyard for U- or H-shaped buildings must be separated from the sidewalk to create a private area; provided, that the enclosure is constructed of transparent building material.

2. Entry into interior courtyards must be provided for first responders.

E. Alternative design compliance may be allowed if the alternative meets or exceeds the purpose of courtyard standards. (Ord. 3220)

21.58.3400 Corner Lots.

A. Purpose. The purpose of corner lot design is to provide informal and welcoming community gathering places, to encourage pedestrian activity, and to enhance the character of the streetscape including continuous pedestrian-oriented storefronts, active retail uses, and a human-scale of the public realm. Corner lot treatments also contribute to wayfinding and placemaking goals.

1. Provide architectural and design distinction of a building from the pedestrian’s perspective.

2. Serve as wayfinding along a street, at an intersection, or across an expanse of the pedestrian realm or public space.

3. Provide informal community gathering places.

4. Extend the public realm and provide park-like space.

5. Highlight an intersection or walkways.

6. The purpose of a corner plaza is to highlight an intersection or walkways by providing a small but well-designed urban space at the corner.

B. Applicability. RZC 21.58.3300 applies to all development in centers and mixed-use zones when the project limits are located at the intersection of two or more public streets.

C. References.

1. See RZC Chapter 21.36, Open Space, for plaza design standards.

2. See RZC Chapter 21.32, Landscaping.

3. See RZC Chapter 21.34, Lighting.

D. Design Standards.

1. The standards are determined by type of streets, as shown in Table 21.58.3400.D.1.

Table 21.58.3400.D.1. Corner Treatment by Intersection Type

Street Type

Urban Core

Urban Mixed/Retail

Landscape Yard/Neighborhood

Shared Street/Limited Access

Urban Trail

Mid-Block Passage

Urban Core

i. Corner plaza required.

ii. Entrance required at corner.

iii. Additional height with FAR reallocation allowed (up to 20 ft. above max height allowed by zone).

i. Corner plaza required.

ii. Entrance required at corner.

iii. Additional height with FAR reallocation allowed (up to 10 ft. above max height allowed by zone).

i. Corner treatment techniques apply.

ii. No additional height.

i. Corner treatment techniques apply.

ii. No additional height.

i. Corner treatment techniques apply.

ii. No additional height.

iii. Pedestrian signage required.

i. Corner treatment techniques apply.

ii. No additional height.

iii. Pedestrian signage required.

Urban Mixed/ Retail Street frontage

i. Entrance required at corner.

ii. Additional height with FAR reallocation allowed (up to 10 ft. above max height allowed by zone).

Landscape Yard/ Neighborhood Street frontage

Shared Street/Limited Access

Urban Trail

Mid-Block Passage

N/A

2. Techniques for corner lot design include but are not limited to the following:

a. Corner plazas, when applicable per Table 21.58.3400.D.1. and installed per Table 21.58.3400.D.2.a;

b. Focal points that create activity;

c. Signature attractions that provide unique identity;

d. Seating, especially if adjacent to local businesses or transit;

e. Water features such as a fountain or artwork with water; or

f. Landscaping features in accordance with RZC Chapter 21.32, Landscaping.

Table 21.58.3400.D.2.a. Corner Plaza Standards

Public Access

Corner plazas should be designed and maintained for year-round public access

Function

Must provide pedestrian access to a primary building entrance

Example Illustration

Min. size

100 sq. ft. minimum

FAR Reallocation Allowed

FAR that is removed from the building envelope to create a corner plaza may be moved to the top of the building as shown below. In such a case the maximum building height on a site may be exceeded per Table 21.58.3400.D.1.

Min transparency

100% of edge lined by retail windows or transparent lobby entrances

Public Seating

For every 60 square feet of plaza area or open space, seating areas must be provided and consist of at least three linear feet of seating area (bench, ledge, etc.) or one individual chair. This provision may be relaxed where there are provisions for movable seating that meet the purpose of the standard

3. Reinforce corner by:

a. Orienting pedestrian entrances toward the corner.

b. Incorporating architectural detailing, cornice work, or frieze design at the building corner and wrapping the detailing for a minimum of five percent of the linear facade.

4. Prioritize connecting existing or planned public and open spaces together that are flexible and large enough for programming.

5. Pedestrian Signage. Locate at least one sign easily visible to a person standing on the sidewalk to provide clear wayfinding to nearby streets and/or attractions.

6. Corner treatments may count toward required common open space if they meet the design requirements in RZC 21.36.400.

E. Alternative design compliance is not permitted for corner plaza standards in Table 21.58.3400.D.2.a but may be allowed for other corner standards if the alternative meets or exceeds the purpose of courtyard standards. (Ord. 3220)

21.58.3500 Building Design for Safety.

A. Purpose. The purpose of RZC 21.58.3500 is to promote building design that increases safety of employees, residents, and visitors.

B. Applicability.

1. RZC 21.58.3500 applies citywide to all new developments.

2. Exemptions. Single-family and middle housing developments are exempt from RZC 21.58.3500.

C. Design Standards.

1. Site design should avoid creating potential entrapment areas.

2. Housing units, offices, or other uses that allow for informal surveillance should surround courtyards and open spaces.

3. Arrange a mixture of uses to minimize isolated areas that may be unsafe.

4. Building design should allow for informal observation of exterior semipublic and public areas, including play areas, open spaces, pathways, and parking lots.

Figure 21.58.3500.C. Site Design for Safety

5. Areas such as laundry rooms and fitness rooms should incorporate windows to increase visibility.

6. Doors to stairways, parking, and similar areas should be open or have windows to allow users to see through to the other side.

7. Increase personal safety by:

a. Avoiding hidden building entries and ensuring good sight lines into entries.

b. Sufficiently lighting doorways and alcoves pursuant to RZC 21.34.080, Security Lighting.

8. When security surveillance devices are proposed, they should be designed to blend through color, scale, placement, and general design with the site and buildings, to the extent possible. Exterior lighting, including for security, must be designed pursuant to RZC Chapter 21.34, Lighting.

D. Alternative design compliance is not allowed for safety standards. (Ord. 3220)

21.58.3600 Building Elements and Details.

A. Purpose. Building design elements and details are intended to support the implementation of placemaking goals and objectives adopted in the Redmond Comprehensive Plan. (Ord. 3220)

21.58.3610 Facades.

A. Purpose. Facade standards are intended to achieve the goals for pedestrian- and bicycle-oriented development and contribute to the creation of high-quality public realm experience.

1. To promote a level of transparency required to achieve a visual link between the business and passing pedestrians, activating the public realm.

2. To achieve a feeling of safety associated with visibility of the street from the interior of abutting businesses.

3. To promote ground floor retail, other commercial uses, and flexible spaces that are engaging and include features that are scaled to and of interest to pedestrians, including the creation of active-use public realm elements such as exterior displays and patios, in order to tie the private realm to the public realm.

4. To implement universal design features that improve wayfinding and accessibility.

B. Applicability.

1. RZC 21.58.3610 applies citywide to all new developments.

2. Exemptions. Single-family and middle housing developments are exempt from RZC 21.58.3610.

C. References.

1. See RZC 21.58.3800, Sustainability and Resiliency Features.

2. See RZC 21.58.3700, Materials and Ornamentation.

3. See RZC 21.58.3650, Blank Wall Treatments.

4. See RZC 21.58.5310, Parking Design, for parking garage transparency standards.

D. Design Standards.

1. Facade Treatments. New development projects must balance solar access and shading based on orientation, seasonal environments, and climate conditions. Use the following techniques:

a. Incorporate trellis, overhangs, latticework, or similar elements at south-facing facades to minimize solar gain during summer months and to provide shade during warm weather.

b. Shading devices, cladding, and roof forms must be designed to facilitate natural ventilation.

c. Integrated photovoltaic is encouraged.

2. Enhance the Public Entries of All Buildings.

a. For multifamily, mixed-use, and nonresidential buildings, provide distinction of every primary entrance for recognition and accessibility using building design features such as but not limited to building modulation, alcoves, color or materials changes, decorative paving, decorative door, artwork, landscaped trellis, or other decorative element that includes landscaping.

i. Provide a minimum of two building design features to distinguish all primary entrances from other entrances.

ii. Provide a minimum of one building design feature to clearly identify secondary entrances.

iii. For buildings within a cultural district utilizing cultural district contributing features is encouraged (see RZC 21.05.200).

b. Provide weather protection at all entryways per RZC 21.58.3640, Weather Protection.

c. Provide at least 100 square feet of landscaping at or near the entry.

d. Provide a minimum of one pedestrian amenity such as benches, rest area, informational kiosks, sensory garden, architectural or tactile design elements less than four feet above the street grade, or low-story vegetated treatments.

3. Facade Transparency. Facade transparency must be established with windows and blank wall maximums per Table 21.58.3610.D.3 with nonreflective, transparent glazing.

Table 21.58.3610.D.3. Facade Transparency

Minimum Transparency Standards

Urban Core Frontage

Urban Mixed/Retail Street Frontage

Mid-Block Passage Frontage

Shared Street/Limited Access

Urban Trail Frontage

Landscape Yard/Neighborhood Street Frontage

Ground Floor

80%

70% for nonresidential

30% for residential

60% for ground floor retail

30% for other uses

40%

30%

2nd to 6th story

30%

20%

30% when adjacent to a park or PEAS space

20%

20%

7th story and above

20% *

30% when adjacent to a park or PEAS space *

20%

N/A

*Also applicable for Bel-Red Rd., 24th St., access streets, local streets, collectors, minor arterials, and 148th Ave NE.

E. Alternative Design Compliance.

1. Mass Timber. Alternative design compliance may be allowed for transparency requirements if the project is a mass timber construction that:

a. Meets the purpose of the transparency standards; and

b. Does not reduce the transparency of the ground floor; and

c. Utilizes inclusive design building features (see RZC 21.58.2000 for examples).

2. Alternative design compliance may be allowed for transparency requirements for the seventh story and above if the alternative meets the purpose of the transparency standards and incorporates integrated photovoltaics in the design for the stories proposed for alternative compliance. (Ord. 3220)

21.58.3620 Ground Floor Retail.

A. Purpose. Ground floor retail design standards set minimum standards to ensure ground floor retail supports the intended public realm and pedestrian experience.

1. To support the multi-modal and pedestrian focus of centers and mixed-use neighborhoods.

2. To enhance the connection between the retail space and the pedestrian realm, and to any exterior seating areas.

B. Applicability.

1. RZC 21.58.3620 applies within centers and mixed-use zones to all new retail and restaurant spaces, including live/work units, where the storefront abuts a street, urban pathway, or plaza.

2. Exemptions. Single-family and middle housing developments are exempt from RZC 21.58.3620.

C. References.

1. See also RZC 21.58.3400, Corner Lots.

2. See also RZC 21.04.2020, Active Retail Uses.

D. Design Standards.

1. Provide visible and universally designed wayfinding or architectural treatments.

a. Entry door must provide automatic entry option (see RZC Appendix 12, Section 12.4, Supplemental Standards for Inclusive Design Features).

b. Recessing the storefront and entryway are allowed.

c. Ensure adequate natural lighting of the interior space.

i. Clerestory windows or similar glazing design are required.

ii. Natural lighting must be available to minimum of 51 percent of the interior space.

d. Include three or more public art, vegetation, lighting, or other elements.

Table 21.58.3620.D. Retail Modulation Requirements

Retail Modulation Requirements

Active Retail Uses and Storefront

Pedestrian-Oriented Uses

Live-Work

Modulation width of storefront facade, including entryway

30 ft. max. including building corners

40 ft. max.

40 ft. max.

2. Ground floor retail and commercial facades on the street wall must contribute to active-use public realm between the facade and the sidewalk for a minimum of 20 percent of the street wall.

a. Active-use public realm elements include street furniture, patio tables for cafe or restaurant uses, temporary exterior display space, and other privately maintained contributions to the public realm during regular operating hours.

b. For buildings with residential tower uses above, the design may consider bringing towers directly to grade to create this active-use public realm at the building entrance, per RZC 21.58.5200.

3. Ground floor retail and commercial facades must include at least three of the elements listed below. Standard corporate logos or architectural elements will not qualify:

a. Unique or handcrafted pedestrian-oriented signage.

b. Artwork incorporated on the facade.

c. Street furniture.

d. Unique or handcrafted planter boxes or other architectural features that are intended to incorporate landscaping.

e. Distinctive facade kick plate treatment, including the use of stone, marble, tile, or other material that provides special visual interest.

f. Weather projection such as awnings.

g. Other design details as approved by the Administrator that add visual interest to the storefronts, such as distinctive treatment of windows or doors, or distinctive exterior light fixtures.

Figure 21.58.3620.D
Ground Floor Retail and Other Commercial Facades

4. The areas on the ground floor of new buildings located along 152nd Avenue NE that are designed and constructed to accommodate future conversion to the pedestrian-oriented uses required by RZC Chapter 21.12 must meet the following standards in addition to other applicable design standards:

a. Minimum average depth of 25 feet measured from the wall abutting the street frontage to the rear wall of the retail use and a minimum width of 20 feet measured from the interior walls of the retail use.

b. Inclusion of an entrance or entrances at the sidewalk level facade to accommodate either a single or multiple tenants or structural design so that entrances can be added when the floor area is converted to pedestrian-oriented uses.

5. If the ground floor is combined into a single commercial use, multiple entrances and the impression of multiple storefronts should be provided. The design should support future partition of this space for flexible uses.

6. Outdoor displays must be oriented to the street and meet the standards of RZC 21.04.2200.

E. Alternative design compliance may be allowed if the alternative meets or exceeds the purpose of ground floor retail design. (Ord. 3220)

21.58.3630 Ground Floor Residential Uses.

A. Purpose. The purpose of RZC 21.58.3630 is to provide minimum design standards for safety, accessibility, and quality of life for ground floor residential units in high pedestrian traffic areas.

1. To ensure that dwelling units at street level are safe and comfortable for the occupants of the units, while also ensuring that the exterior of the unit is attractive and pedestrian-friendly for people walking on the street sidewalks.

2. To ensure that there is adequate separation from the ground floor residential unit and pedestrian way for privacy of residents and to minimize noise and other impacts.

B. Applicability.

1. RZC 21.58.3630 applies to all development in centers and mixed-use zones where ground-floor residential uses are permitted (see zone standards in RZC Article I).

2. Exemptions. Single-family and middle housing developments are exempt from RZC 21.58.3630.

C. References.

1. See RZC Chapter 21.35, Live-Work.

2. See RZC 21.55.400 for incentives for ground-floor ADA units.

3. See RZC 21.58.3610, Facades.

4. See RZC 21.58.2000, Universal Design.

D. Design Standards. Where allowed in centers and mixed-use zones, units must comply with the following design standards:

1. Ground floor residential units along the street must be set back a minimum of six feet from, and no more than eight feet from, the back of the required street sidewalk, or the minimum setback required for the zone, whichever is greater.

2. Universal design, visitability standards, and ground floor ADA units are encouraged and may be incentivized.

3. Primary or secondary access to the unit must be provided via a front door at the street or walkway to patio/porch along the street unless the unit is interior to the block or otherwise not directly facing a street frontage.

4. Live/Work Units. Ground floor live/work units must comply with zoning district ground floor clearance requirements and ground floor retail design standards in RZC 21.58.3620, Ground Floor Retail.

E. Alternative design compliance may be allowed if the alternative meets or exceeds the purpose of ground floor residential uses, as described within RZC 21.58.3630. (Ord. 3220)

21.58.3640 Weather Protection.

A. Purpose. The purpose of RZC 21.58.3640 is to enhance pedestrian safety and comfort.

1. To establish sheltered walking corridors and entryways that mitigate adverse weather conditions, promote active transportation to reduce reliance on vehicles, and foster community connectivity through inviting pedestrian environments.

2. The addition of weather protection can elevate the aesthetic quality of the urban environment through thoughtful design, while ensuring accessibility for individuals of all abilities.

B. Applicability.

1. RZC 21.58.3640 applies citywide to all new developments.

2. Exemptions. Single-family and middle housing developments are exempt from RZC 21.58.3640.

C. Design Standards.

1. Facade Weather Protection. New development projects in centers and mixed-use zones must provide facade weather protection for pedestrians at all street frontages.

a. Must be provided along at least 80 percent of the building frontage.

b. Must be contiguous, including on adjoining buildings.

c. Must be permanent and durable, such as but not limited to glass or steel canopy.

d. May use integrated photovoltaic features.

Table 21.58.3640.C. Facade Weather Protection

Arcade

Canopy or Awning

Description

• The arcade frontage type requires the ground floor to be constructed at or close to sidewalk grade.

• Ceiling beams and light fixtures that are located within the column space geometry greatly enhance the quality of the space and should be included in the design and installation.

Development must not include arcade-like features with ground-level residential use.

• The canopy or awning frontage type requires rigid construction over which a covering is attached that provides weather protection, identity, or decoration.

Must be removable to allow utility access.

Dimensions

Min clear depth (A)

10 feet

N/A

Min clear height (B)

12 feet

8 feet measured from finished grade

Maximum clear height

20 feet

12 feet from finished grade

Minimum spacing

Min. 10 feet between columns

N/A

Maximum spacing

Max. 20 feet between columns

N/A

Other

N/A

Minimum depth over public sidewalk of 6 feet, regardless of the sidewalk width

Figure 21.58.3640.C.1. Example of Arcade with Integrated Photovoltaic

2. Entry Weather Protection. All new development must provide covered weather protection at primary entry such as an awning, canopy, marquee, recessed entry or other building element.

Figure 21.58.3640.C.2.a
Entry Weather Protection

3. Weather-Protected Loading and Unloading Zones. For public and semi-public buildings with assembly uses with a seating capacity of 150 or greater a covered loading and unloading zone is required, with a minimum clearance of 13.5 feet to ensure paratransit vehicles can utilize the area.

D. Alternative design compliance is not permitted for weather protection requirements. (Ord. 3220)

21.58.3650 Blank Wall Treatments.

A. Purpose. The purpose of blank wall treatment is to reduce the appearance and mass of large walls.

1. Blank wall treatment includes the use of various architectural, artistic, and landscaping treatments to support city, neighborhood, district, and individual site character as well as the community visions and values as reflected in the Comprehensive Plan and Redmond Zoning Code.

2. The treatments provide visual interest over the exterior of a building.

3. The use of vegetated treatments involving the maintenance of living vegetation in a meaningful and aesthetic way can complement building design.

4. The use of vegetated treatments has the potential to contribute to cooling and shading for the site and occupants.

5. The use of vegetated treatments has the potential to mitigate the urban heat island effect.

6. The use of vegetated treatments has the potential to provide habitat and habitat connections.

7. The use of vegetated treatments has the potential to meet stormwater requirements.

8. The use of public art as a treatment provides an opportunity to express city, neighborhood, and community identity, culture, traditions, and history, as well as creativity, distinction, and innovation.

B. Applicability.

1. Blank wall treatment is applicable in centers and in business park and mixed-use zones to all new development projects.

2. Exemptions.

a. Service areas that are not visible from a public street.

b. Building facades facing the interior of the lot that do not face pedestrian-oriented pathways or spaces or resident amenity spaces.

c. Single-family and middle housing developments are exempt from RZC 21.58.3650.

C. Design Standards.

1. Blank walls must not be used on the building facades that face sidewalks, trails, mid-block pedestrian pathways and other pedestrian-oriented spaces.

2. Blank wall treatment must be applied to a minimum of the building facade as shown in Table 21.58.3650.C.2.

Table 21.58.3650.C.2. Blank Wall Maximum

Urban Core Frontage

Urban Mixed/Retail Street Frontage

Mid-Block Passage Frontage

Shared Street/Limited Access

Urban Trail Frontage

Landscape Yard/Neighborhood Street Frontage

Ground Floor

10 ft.

20 ft.

2nd to 6th story

20 ft.

20 ft.

30 ft.

30 ft.

30 ft.

20 ft.

7th story and above

40 ft.

20 ft.

N/A

3. Blank Wall Ornamentation Alternative. Blank wall maximum may be increased to 30 feet maximum on second to sixth stories if green wall or public art is provided as a blank wall treatment (see RZC 21.58.3650.C.4).

4. Blank walls must be treated by using one or more of the following techniques:

a. Install windows or a green wall to separate the blank areas, horizontally or vertically, below the blank wall dimensional threshold.

b. Vegetation.

c. Public artwork (mosaic, mural, sculpture, relief, etc.). Interactive and/or sensory art may be eligible for incentives (see RZC Chapter 21.55).

d. Integrated photovoltaic features.

e. In cultural districts elements that reflect the cultural diversity of the community are encouraged, such as murals and decorative architectural elements. Such elements used to treat a blank wall may also be utilized for any applicable incentive points if visible from the public ROW or trail and the total size of such elements is greater than 80 square feet in size (see RZC Chapter 21.55 for incentive options).

f. Mass timber exposed timber element.

5. For blank wall mitigation involving vegetation, plants must be selected from the City of Redmond Climate Resiliency and Sustainability Vegetation Management Plan (CRSVMP).

a. Vegetation must meet one or more of the landscaping standards and one or more of the bed types as show in Table 21.58.3560.C.4.

Table 21.58.3650.C.4. Vegetation Standards for Blank Wall Mitigation

CRSVMP Landscaping Standards (Use One or More)

Bed Types (Use One or More)

A. Tree canopy; or

B. Understory; or

C. Roadside meadow, or

D. Pollinator garden.

A. Naturalized meadow that is at least five feet wide; or

B. Raised planter bed at least two feet high and three feet wide in front of the wall or minimum required for selected plant types, whichever is greater.

b. Plant materials must achieve a minimum of 80 percent density over at least 50 percent of the wall’s horizontal and vertical surface within three years.

c. Vegetated blank wall treatments may be co-located with solar infrastructure.

d. Maintenance. A maintenance plan for resiliency and longevity must be included as part of project submittal.

D. Alternative design compliance may be allowed if the alternative meets or exceeds the purpose of blank wall treatments and provides architectural justification, and alternative does not propose an increase in size of over 10 percent of the maximum blank wall standards in RZC 21.58.3650. (Ord. 3220)

21.58.3700 Materials and Ornamentation.

A. Purpose. The purpose of RZC 21.58.3700 is to achieve the placemaking, sustainability, and resiliency goals of the Redmond Comprehensive Plan.

1. Promote visual interest and distinction of new development within the neighborhood, district, along the street front, and to be reflective of the community’s goals, vision, and diversity.

2. Promote visual interest, distinct design qualities, and an appearance of quality and permanence through use of durable building materials and effective architectural detailing.

3. Promote the use of high quality, durable, sustainable, and resilient materials that contribute to the unique identity of buildings and their location within Redmond.

4. Contribute to the honest expression of the building’s architecture and individual design components.

5. Support the story of the building in relationship to Redmond, the region, history, culture, and community.

6. Support resiliency, environmental sustainability, and innovation.

7. Building ornamentation contributes to the unique identity of the building and its location within Redmond.

B. Applicability.

1. RZC 21.58.3700 applies citywide to all new developments.

2. Exemptions. Single-family and middle housing developments are exempt from RZC 21.58.3700.

C. References.

1. See RZC 21.58.0100 for small building alternative ornamentation requirements.

2. See Table 21.58.3100.C.4 for ornamentation alternative to building width.

3. See RZC 21.58.3100 for ornamentation alternative to building break.

4. See RZC 21.58.3650 for blank walls.

5. See RZC 21.58.5100 for mass timber construction flexibility.

6. See RZC 21.05.200 for cultural districts.

7. See RZC Chapter 21.30, Historic and Archaeological Resources.

8. See RZC Chapter 21.22, Public Art.

9. See RZC Chapter 21.55 for development incentives.

D. Design Standard.

1. Ornamentation.

a. Use public art, vegetation, textured materials (e.g., glazing, ceramics, patterned materials) or another treatment type architecturally integrated into a minimum of the first three floors of a building to accent building features or building breaks.

b. Ornamentation should reflect the vision and placemaking goals of centers, neighborhood, and cultural districts as adopted in the Redmond Comprehensive Plan.

2. Cultural District Contributing Features. (Reserved).

3. General Materiality.

a. Facade materials are allowed or prohibited as shown in Appendix 13, Materials List.

b. Select materials for their resiliency to changing climate conditions, their durability and ease of maintenance throughout the life of the building, and their impact on environmental sustainability.

c. For properties within the Old Town district (see RZC 21.58.1100.D.3.b), materials selection should blend with or be complementary to Redmond’s historic built environment. See RZC 21.58.1100.D for standards on relationship of building to neighboring properties.

4. Supplementary Design Standards and Limitations.

a. Masonry or other similar durable/permanent materials must be used for watercourse;

b. Use of cementitious panel is prohibited except for locations such as accent areas and soffits;

c. Concrete Block. When used for the facade of any building, concrete blocks must be split, rock- or ground-faced. Concrete block may be used if it is incorporated with other permitted materials, and it complies with the following: When used for the primary facade, buildings must incorporate a combination of textures and/or colors to add visual interest (for example, combining split or rock-facade units with smooth blocks can create distinctive patterns); and

d. Exterior Insulation and Finish System (EIFS) and Similar Troweled Finishes (Stucco).

i. Must be trimmed in wood, masonry, or other approved materials, and must be sheltered from extreme weather by roof overhangs or other methods.

ii. Prohibited on ground floor facades and watercourse.

e. Metal Siding. Architectural grade metal siding may be used if it is incorporated with other permitted materials, and it complies with the following:

i. Visible corner molding and trim; and

ii. Does not extend lower than two feet above grade. Masonry, concrete, or other durable material must be incorporated between the siding and the ground plane; and

iii. Factory finished with a matte, nonreflective surface.

E. Alternative design compliance may be allowed for materials that meet or exceed the purpose of materials and ornamentation standards or to achieve green building or universal design certification. (Ord. 3220)

21.58.3800 Sustainability and Resiliency Features.

A. Purpose. Redmond experiences extreme climate events, such as high temperatures and heatwaves consistent with climate change projections. The Redmond community can anticipate the following climate impacts:

1. More hot days and higher summertime average temperatures, requiring more homes to be equipped with cooling systems.

2. Greater heat island impacts in areas with fewer trees.

3. Greater prevalence of wildfires and wildfire smoke, increasing the need for indoor air filtration and cooling.

4. More extreme rain events that increase the risk of flooding.

RZC 21.58.3800 identifies standards to adapt to these impacts and implement the Redmond Comprehensive Plan and the Redmond Environmental Sustainability Action Plan.

B. Applicability.

1. RZC 21.58.3800 applies citywide to all new development.

2. Some requirements do not apply to single-family and middle housing developments (see Table 21.58.3800).

C. References.

1. See RZC Chapter 21.16, Site Requirements Measurement and Other Applicable Regulations, for exemptions to building heights and setbacks for green building techniques and materials.

2. See RZC Chapter 21.32, Landscaping.

3. See RZC Chapter 21.55, Development Incentive Program, for incentives for sustainability and resiliency features.

4. See RZC 21.58.4200, Stormwater Facilities, for stormwater requirements.

5. See RZC 21.58.5100 for mass timber construction.

6. See RZC Chapter 21.67, Green Building Program (GBP), and RZC Appendix 10, for the Green Building Program. RZC Chapter 21.67, Green Building Program (GBP), includes a list of mandatory green building elements and where they apply.

7. See the City of Redmond Climate Resiliency and Sustainability in Vegetation Management Plan.

D. Design Standards.

1. Development of the site and structures must mitigate and provide resilience to extreme heat and extreme precipitation events and advance sustainability. The following techniques must be demonstrated, with minimum requirements per Table 21.58.3800:

a. Urban heat island mitigation at street level along the primary street frontage;

b. Flood prevention in exterior open spaces; and

c. Elements that support resilience and sustainability in building exterior design.

Table 21.58.3800. Sustainability and Resilience Features

Urban Heat Island Mitigation

Flood Prevention*

Resiliency and Sustainability

Select 2 minimum

Select 2 minimum

Single-family and infill middle housing development are exempt (encouraged but not required).

Select 4 minimum

For single-family and middle housing development, select 2

Shaded structures or arcades

See RZC 21.58.3640, Weather Protection

Bioswales and bioretention

See RZC 21.58.4200, Stormwater Facilities

Light colored exteriors

Trees and shrubs. Exceed ecological score requirement by 5 points (see RZC 21.32.100)

Maximized planted permeable surfaces

See RZC 21.58.4200, Stormwater Facilities

Double skin facade

Solar shade structures

Green roofs

See RZC 21.58.3650, Blank Wall Treatments

Window shading for all windows that receive direct sunlight

Light colored pavement materials and coatings

(Cement concrete, chip seals, permeable interlocking concrete pavers, pervious concrete, porous asphalt, stone, etc.)

Vegetated planters

See RZC 21.58.3650, Blank Wall Treatments

Vegetated walls

See RZC 21.58.3650, Blank Wall Treatments

Rain gardens

See RZC 21.58.4200, Stormwater Facilities

Building integrated or roof-mounted PV systems

Infiltration systems for roof runoff

See RZC 21.58.4200, Stormwater Facilities

Passive ventilation design

See RZC 21.58.3610, Facades

Permeable pavement in alignment with the Stormwater Technical Notebook

Passive heating/cooling

See RZC 21.58.3610, Facades

Incorporate trellis, overhangs, latticework, or similar elements at south-facing facades

See RZC 21.58.3610, Facades

High performance glazing

* Note: All flood prevention techniques must be in alignment with the Stormwater Technical Notebook.

2. Features that meet this requirement may also be used to meet other requirements of RZC Chapter 21.58. Integrating public art and amenities is encouraged (e.g., solar panels that shade rooftop seating areas).

E. Alternative design compliance may be allowed for features that meet or exceed the purpose of RZC 21.58.3800. (Ord. 3220)

21.58.4000 Site Design, Connectivity, and Public Realm.

(Ord. 3220)

21.58.4100 Planting Design.

A. Purpose. Planting design is an integral part of the overall site and community design. It complements the architecture, other site elements and the visual appearance of the neighborhood, as well as the Northwest environment. Landscaping helps reduce impacts and create a transition to adjacent natural features, such as critical areas and shorelines.

B. Applicability.

1. RZC 21.58.4100 applies to all development in centers, mixed-use zones, and in the NMF zone.

2. Exemption. Infill single-family and infill middle housing are exempt from RZC 21.58.4100.

C. References.

1. See also RZC Chapter 21.32, Landscaping.

2. See also RZC Chapter 21.36, Open Space.

3. See also City of Redmond Climate Resiliency and Sustainable Vegetation Management Plan.

D. Design Standards.

1. Retention and Enhancement of Existing Vegetation. Preserve as much native noninvasive vegetation as possible, particularly adjacent to buffers of critical areas and shorelines. Replant developed areas with stands of nondwarf evergreens in natural and random patterns where possible.

2. Open Space and Public View Corridors. Provide space on site for active or passive recreational purposes. When located in an identified public view corridor, this open space may also provide views through a development to important features, such as Lake Sammamish, Sammamish River, and the river valley; Bear Creek; or panoramic mountain views.

3. Transition. Provide plantings that provide a clear transition in design between adjacent sites, within a site, and from native vegetation areas. To lessen impacts and provide transitions to natural areas, use native plants as much as possible adjacent to the buffers of critical areas and shorelines. Design foundation plantings to create an effective change from public to private space and from the vertical to horizontal plane at building edges.

4. Mitigation of Adverse Visual Impacts. Provide planting to soften the visual impact of less desirable development and structures, such as large blank walls, dumpster areas, service areas, and large areas of pavement.

5. Definition or Emphasis. Use planting to highlight significant site features and to define site use areas and circulation corridors without interfering with the use of such areas. Examples include site and building entrances, pedestrian walkways, and focal points, such as gathering areas or plazas.

Figure 21.58.4100.C
Site Landscaping

6. Safety. Use planting landscaping that minimizes disruption of sight lines along pathways.

7. Water Conservation. Plants and techniques that reduce water consumption are encouraged.

8. Plants should be selected and arranged according to the following design criteria:

a. Variety. Select a variety of plants providing interest, accent and contrast, and climate resilience while using as many native species as possible. See the City of Redmond Climate Resiliency and Sustainable Vegetation Management Plan for vegetation guidance.

b. Consistency. Where abutting a landscaping or open space on neighboring property, incorporate a minimum of two design elements or plants to visually connect the spaces.

c. Appropriateness. Select plants with an awareness of their growth requirements, tolerances, ultimate size, preferences for soil, climate, and sun exposure, and negative impacts.

d. Density. Provide adequate plant quantity, size, and spacing to fulfill the functional and design objectives within three years.

E. Alternative design compliance is not allowed for planting design standards. (Ord. 3220)

21.58.4200 Stormwater Facilities.

A. Purpose. The purpose of RZC 21.58.4200 is to provide minimum design standards for safety and quality for stormwater facilities.

1. To provide options for stormwater facilities that are visually attractive;

2. To incorporate open stormwater facilities into project site design and landscaping as a design amenity for active or passive recreation;

3. To avoid potential hazards between persons and stormwater facilities.

B. Applicability.

1. RZC 21.58.4200 applies citywide to all new development.

2. Exemption. Infill single-family and infill middle housing are exempt from RZC 21.58.4200.

C. Design Standards.

1. Design stormwater facilities to appear as naturally occurring features.

2. Stormwater facilities must be designed to address the following:

a. Landscaping must be incorporated into stormwater pond, bioretention, and biofiltration facility design to the extent practicable without compromising the facility’s function and maintenance. Screening elements must be incorporated into pond and biofiltration swales design. Trees may be planted near biofiltration swales as long as they are a minimum of eight feet from the swale, and they will not inhibit vegetative growth within the swale.

b. Aboveground stormwater facilities must be oriented so they do not impede pedestrian circulation or shared parking between two or more properties. Pedestrian bridges are acceptable where such crossings are necessary.

c. The City’s standard detail for bioretention facility construction and the plant palette to be used within them can be found in the City of Redmond Standard Specifications.

d. Where adjacent to natural shoreline areas, aboveground stormwater facilities must be landscaped with native plants, and should include snags, nest boxes, or other habitat features as appropriate for the scale, function, and location of the facility.

e. Engineering design requirements for stormwater facilities are contained in the City of Redmond Stormwater Technical Notebook and Washington State Department of Ecology’s Stormwater Management Manual for Western Washington.

3. Stormwater Management Facilities in RA-5 and NR Zones.

a. All surface ponds must be landscaped with native vegetation or other vegetation that is drought tolerant, provides desired screening or wildlife habitat, or for other purposes as needed for the individual site. Unobstructed maintenance access must be provided.

b. Fencing, if required, must allow the passage of small wildlife species below it. Galvanized steel chain link fences are prohibited.

c. Privately maintained stormwater facilities are encouraged to be designed for multiple uses including, but not limited to, gardens, play areas, or sports courts.

D. Alternative design compliance may be allowed for features that meet or exceed the purpose of RZC 21.58.4200 where site limitations impact design options and where the alternative meets the requirements in the Redmond Stormwater Technical Notebook. (Ord. 3220)

21.58.4300 Transit Connectivity.

A. Purpose. Transit connectivity design standards ensure that new construction is supportive of transit use.

1. To encourage transit use through building orientation and site design;

2. To provide safe and continuous pedestrian access to transit facilities;

3. To consider minimizing the distance between buildings and transit stops; and

4. To encourage weather protection for those waiting for transit.

B. Applicability.

1. RZC 21.58.4300 applies citywide to all new development.

2. Exemptions.

a. Single-family infill and middle housing infill development are exempt from these standards.

b. Developments on local streets are exempt from these requirements.

C. Design Standards.

1. Provide transit stops and improvements along corridors where transit is planned in the future as documented in the Transportation Master Plan. Transit stops must include space for shelters meeting transit agency standards and 10 feet between the curb to the back of sidewalk, unless other site requirements require a larger sidewalk. The area devoted to shelters and wider sidewalks may be included in setbacks and may be counted toward required landscaping.

2. Install passenger bulb-outs at transit stops on arterials, except when doing so would interrupt a bicycle facility or vehicle travel lane.

3. Provide direct access to abutting streets with transit stops from buildings via defined, safe pathway systems. Building entries should be located to minimize the distance to transit stops. See Figure 21.58.4300.C.3.

D. Alternative design compliance may be allowed when the alternative design meets or exceeds the purpose of RZC 21.58.4300.

Figure 21.58.4300.C.3
Transit Access

Pedestrian access to transit provided across the block

E. Alternative design compliance may be allowed if the alternative meets the purpose of RZC 21.58.4300. (Ord. 3220)

21.58.5000 Special Regulations by Construction Method or Building Type.

(Ord. 3220)

21.58.5100 Mass Timber.

A. Purpose. Mass timber construction implements several sustainability and resiliency goals as adopted in the Redmond Comprehensive Plan and the Environmental Sustainability Action Plan. RZC 21.58.5100 provides additional flexibility to support mass timber construction while maintaining a high-quality user experience.

1. Ensure code allows for designs that maximize the potential of mass timber structural abilities where they differ from typical building materials while meeting minimum building user experience expectations.

2. Maximize the potential for mass timber construction to contribute to a diversity of shapes in buildings and spaces to meet placemaking goals.

3. Ensure minimum quality standards that contribute to the public realm and user experience.

B. Applicability.

1. RZC 21.58.5100 applies citywide to all new construction utilizing mass timber.

2. Exemption. Single-family developments are exempt from RZC 21.58.5100.

C. References.

1. See incentives for mass timber and other green building incentives in RZC Chapter 21.55.

2. See RCW 19.27.570 for mass timber construction products.

D. Design Standards and Considerations.

1. Exposure of timber elements must be provided in prominent locations on facades facing public right-of-way and are encouraged on the interior at the following locations:

a. In primary public assembly and waiting areas of the building interior;

b. On a minimum of one feature wall or ceiling within each residential unit;

c. On a minimum of one feature wall within nonresidential units; and

d. On a minimum of one ceiling and building columns within nonresidential units.

2. Mass timber construction that utilizes the flexibility of the materials for providing nonrectilinear spaces and complex shapes is encouraged, especially within the Centers.

3. Buildings that utilize mass timber from ground up are encouraged within the CARA 1 areas.

E. Alternative design compliance for mass timber construction is allowed for alternative building modulation and articulation dimensions, location of building stepbacks, facade, and ground floor requirements for features that meet or exceed the purpose of RZC 21.58.5100 when one or more of the following are true:

1. Flexibility is required to meet the applicable Washington State mass timber building or fire codes; or

2. Flexibility is needed to allow for mass timber construction to begin at the ground level (without a concrete podium level). (Ord. 3220)

21.58.5200 Towers.

A. Purpose. The intent is to allow for creativity in building design while still minimizing the impacts of the building massing, keeping a pedestrian friendly design, and managing sunlight/shadows. Creative use of stepbacks, floor plate averaging, and upper story landscaping and amenities are all encouraged.

B. Applicability. RZC 21.58.5200 applies citywide to all buildings taller than 85 feet. Standards apply to the floors at or above 85 feet and not to floors below that height.

C. Design Standards.

1. Tower Floorplates.

a. The floorplate size for a tower must be based on use per Table 21.58.5200.C.1.a.

i. Floorplate size may be an average (the total cumulative tower floorplate area of all applicable levels divided by the number of tower stories).

ii. Floorplate must be measured by the exterior of the enclosed wall.

Table 21.58.5200.C.1.a. Floorplate Maximum by Floor Height

Primary Use

Above 85 Feet to 180 Feet

180 Feet – 240 Feet

Over 240 Feet

Office/Nonresidential

Average of 35,000 sq. ft., with 45,000 sq. ft. max. per tower

20,000 sq. ft. max.

Residential, Mixed-Use, or Hotel

N/A

12,500 sq. ft. max.

10,500 sq. ft. max.

b. All other requirements of RZC Chapter 21.58 also apply and might also result in impacts to floorplate sizing, including but not limited to tower spacing, street wall modulation, and courtyard sunlight requirements.

2. Tower Placement.

a. Towers must be designed to consider livability of adjacent buildings and to optimize a thin skyline to allow for light capture and solar access while minimizing impacts of shadows.

b. Use context and conditions to set the elevation of the setback or location of towers, to preserve sightlines or approximately align with the heights of adjacent contextual elements (such as landmark spire or clocktower, a historic building, etc.).

3. Tower Stepback and Spacing.

a. Towers must be offset 20 feet horizontally from all property lines (see Figure 21.58.5200.C.2.b).

b. Towers must be placed with a minimum of 80 feet separation face-to-face and a minimum of 60 feet separation corner-to-corner from all towers on site, as well as buildings on adjacent properties above six stories (see Figure 21.58.5200.C.2.b).

Figure 21.58.5200.C.2.b
Tower Separation

Building edge offset from street frontage: 20 feet minimum.

Building offset from all other property lines: 20 feet minimum.

Tower separation: 80 feet face-to-face.

Tower separation: 60 feet corner-to-corner.

c. A tower may be brought directly to grade if it meets one of the following criteria:

i. When the tower is placed in the middle of a long block, to assist in modulation and create a clear center of the building; or

ii. When the tower is placed on the corner of two streets, to create a visual landmark at the entrance and a larger public realm element at an intersection (see Figure 21.58.5200.C.3.c).

Table 21.58.5200.C.3.c. Towers to Grade Examples

4. Tower Rooftop.

a. The top of each tower must use two or more unique architectural expressions, additional stepback, or double height elements to contribute to a unique city skyline.

b. Rooftop amenities, including green roofs, are encouraged. All rooftop amenity spaces must be accessible for all ages and abilities.

c. All mechanical elements must be screened or placed within a parapet to the top height of the mechanical equipment (see Figure 21.58.5200.C.4.c) and provide an architectural contribution to the building.

Table 21.58.5200.C.4.c. Mechanical Screening

D. Alternative design compliance may be allowed if the alternative meets the purpose of RZC 21.58.5200.

1. All alternatives that provide two or more of the following:

a. Similar or better shadow conditions for solar capture; or

b. Access to publicly accessible podium or rooftop amenities; or

c. Material needs or code requirements for mass timber, passive house, or other green building certification.

2. All alternatives must not:

a. Exceed max FAR or building heights; and

b. Result in greater wintertime shadows at ground level along urban core, urban mixed, retail, shared or limited access street types or onto urban pathways; and

c. Create housing units closer than 60 feet to a major arterial or freeway. (Ord. 3220)

21.58.5300 Parking Facilities.

See also RZC Chapter 21.40, Parking Standards. (Ord. 3220)

21.58.5310 Parking Design.

A. Purpose. The purpose of RZC 21.58.5310 is to create well-designed parking areas that minimize visual impact, support accessibility, and preserve public and natural open spaces.

1. To limit the visual impact of surface parking lots, ensure active-use public realm is supported around the building (including sidewalks, plazas, and spill-out outdoors uses), and provide opportunities for multimodal connectivity.

2. To ensure that parking garages can accommodate ADA vans and other vehicles for community members with disabilities that require a high clearance (public and private).

3. To provide for clear internal vehicle circulation patterns and consideration of pedestrian walkways in parking lots.

4. To set standards for paving, lighting, and other design elements.

5. To provide for joint entrances and exits.

6. To reduce the negative impacts of parking and circulation facilities on highly visible public open spaces, such as shorelines and other natural open spaces.

B. Applicability.

1. RZC 21.58.5310 applies to all developments in centers and in mixed-use, BP, and MP zones.

2. Exemption. Single-family and middle housing developments are exempt from RZC 21.58.5310.

C. Design Standards.

1. No new surface parking lots are permitted in Overlake Village. Developments must adhere to the standards in RZC 21.40.010 on any nonconforming parking.

2. General Requirements.

a. Ground level street frontage must be limited to a maximum of 40 feet of parking related uses, including the following:

i. Parking entrances and access points.

ii. Accessible parking stalls.

iii. Space for car-sharing services.

iv. Ride-share or shuttle drop-off and pick-up points.

v. Visitor bicycle parking with facade treatments to maximize visibility.

b. Locate parking behind buildings and away from areas of public visibility and shorelines.

c. Integrate parking area design with landscape design in a way that reduces the visual impact of impervious surfaces and provides adequate screening of parking from public view, while allowing sufficient visibility to enhance safety. Parking areas should provide for landscaping next to buildings and alongside walkways.

d. Reduce pavement areas for vehicular use by avoiding the use of parking aisles with parking located only along one side.

e. Convenient, clearly identified pedestrian access must be provided from the interior of parking areas and street front walkways. See Figure 21.58.5310.C.2.e.

Figure 21.58.5310.C.2.e. Parking Lot Pedestrian Walkway

f. Site layout for individual parcels should be designed to provide reciprocal vehicular and pedestrian access to and from adjoining lots in order to achieve a unified circulation plan which minimizes curb cuts and provides pedestrian connections between uses.

3. Parking Garages.

a. In order to meet transparency requirements (See RZC 21.58.3610, Facades), above-grade garages must incorporate openings with grillwork or other treatments to resemble windows. Where the garage wall is built to the sidewalk edge, the facade must also include treatments to enhance the pedestrian environment, such as artwork, decorative grilles, and special building material treatment/design.

b. First-floor parking garage level must have a minimum clearance of 10 feet for the first 40 feet of parking or through the first set of ADA accessible parking spaces, whichever is greater.

c. Where parking garage is not wrapped with other uses, the exterior facade of upper levels must use articulation, treatments that resemble windows such as decorative grilles or artistic scrims, green walls, or other devices to break up the massing of the garage, add visual interest, and convey an appearance more like a typical building floor rather than a floor of visible cars. RZC 21.58.3610, Facades, transparency standards and RZC 21.58.3650 blank wall standards apply.

d. Structured parking should be designed to include articulated planes. The scale of parking structures must be modulated by interruptions of the facades, setbacks, and lowering the first level below the existing grade (where the water table allows, see RMC Chapter 13.25, Temporary Construction Dewatering) to reduce total height.

e. Parking structures must have landscaping around the perimeter which will correspond to that used by the adjacent land uses and activities. Landscaping must include, but not be limited to, a combination of shade trees, evergreen trees, shrubs, groundcovers, deciduous native and ornamental shrubs, and vines to further screen the structures.

f. The top floor of parking structures should include landscape screening in areas, such as along the cornice and on the deck, either by trees or a screening trellis treatment if visible from residential zones or SR 520.

g. Provide walkways in parking floors that have curbs or other barriers to protect from vehicular intrusion.

h. For security, pedestrian routes must be visible and avoid enclosed, hidden areas. Emergency call boxes should be available.

Figure 21.58.5310.C.3
Parking Garage Design

D. Alternative design compliance may be allowed when the alternative meets or exceeds the purpose of RZC 21.58.5310. (Ord. 3220)

21.58.5320 Parking Lot Landscaping.

A. Purpose. Parking lot landscaping minimum requirements provide for comfort and safety of users and mitigate heat and environmental impacts of surface parking lots.

1. To improve the aesthetic appearance of parking lots;

2. To reduce the summertime heat and glare buildup within and adjacent to parking lots;

3. To provide landscaped areas within parking areas in addition to landscape buffers around the perimeter of parking lots;

4. To provide screening and break up the expanse of paved areas.

B. Applicability.

1. RZC 21.58.5320 applies citywide to all development.

2. Exemption. Single-family and middle housing developments are exempt from RZC 21.58.5320.

C. References.

1. See RZC Chapter 21.32, Landscaping.

2. See the City of Redmond Climate Resiliency and Sustainability in Vegetation Management Plan.

D. Design Standards.

1. Disperse interior parking lot landscaping throughout a parking lot when no significant existing vegetation exists.

2. Shade trees must be used to shade parking lots and driveways to reduce summer heat loads.

3. Provide landscaped areas within parking areas and a Type II Visual Screen (See RZC 21.32.120) around the perimeter of parking lots.

4. All parking lots must be planted with sufficient trees so that within 10 years, 50 percent of the surface area of the lot is shaded.

E. Alternative design compliance is not allowed for parking lot landscaping requirements. (Ord. 3220)

21.58.5500 Screening for Mechanical Instruments.

A. Purpose. The screening for mechanical instruments requirements minimize the visual impacts of service and mechanical equipment.

1. To reduce the visual and physical impacts of service areas, mechanical equipment, and other similar uses on other on-site uses, the street environment, adjacent shoreline areas, and other public open spaces, and adjacent properties, while maintaining accessibility for service providers and users.

2. To mitigate the off-site visual impacts of service and mechanical equipment areas when siting alone does not adequately mitigate impacts.

B. Applicability.

1. RZC 21.58.5500 applies citywide for all multifamily, mixed-use, and nonresidential buildings.

2. Exemption. Industrial and manufacturing uses with no abutting residential are exempt from these requirements.

C. Design Standards.

1. Large utility cabinets and mechanical equipment must be located away from highly visible areas, such as streets, pedestrian walkways, and public shoreline areas, to minimize visual, noise, or physical impacts on the site, street environment, adjacent public open spaces, and adjacent properties.

2. All mechanical equipment, including air conditioners, heaters, vents, and similar equipment, rooftop and ground-mounted, must be fully screened from public view both at grade and from higher buildings with the exception of solar panels and roof-mounted wind turbines. Screening must be located so as not to interfere with operation of the equipment. All mechanical equipment must meet the applicable requirements of the Uniform Mechanical Code and Uniform Plumbing Code and:

a. The screening materials must be of material requiring minimal maintenance and must be as high as the equipment being screened.

b. For ground-mounted equipment, landscaping may be used if a solid screen is provided at time of planting and public art is encouraged.

c. For rooftop equipment, all screening devices must be well integrated into the architectural design through such elements as parapet walls, false roofs, roof wells, clerestories, or equipment rooms. Screening walls or unit-mounted screening is allowed but less desirable. Wood should not be used. Louvered designs are acceptable if consistent with building design style.

Figure 21.58.5500.C.1
Rooftop Screening

Roof wells conceal mechanical equipment.

3. Screening should incorporate landscaping.

4. All utility meters must be fully screened from view from a public right-of-way. If enclosed in cabinets visible from public rights-of-way, exterior surfaces must be finished with art or with the same materials or colors of the building.

Figure 21.58.5500.C.2
Landscaping and Other Site Design Methods

5. Screening structures must comply with the International Building Code or International Residential Code, as adopted in RMC Chapter 15.08, Building Code, and a building permit may be required. Applicants may wish to contact the Building Division for all requirements.

D. Alternative design compliance may be allowed where alternative is to implement a green building standard or incorporate public art and the solution is equivalent or better at screening mechanical equipment from the public realm. (Ord. 3220)

21.58.5530 Kiosks and Drive-Up Stands.

A. Purpose. The purpose of RZC 21.58.5530 is to enhance enjoyment and safety for those arriving on foot, by bicycle, and in cars.

B. Applicability. RZC 21.58.5530 applies citywide to all kiosks and drive-up stands where they are permitted (see RZC Chapter 21.04).

C. References.

1. See also RZC 21.04.2090, Drive-Up Stand.

2. See also RZC 21.04.4040, Kiosks and Vending Carts.

D. Design Standards. Two sides of the kiosk or drive-up stand must incorporate small-scale landscaping a minimum of four square feet in size, such as planter boxes.

E. Alternative design compliance may be allowed when the alternative meets or exceeds the purpose of RZC 21.58.5530. (Ord. 3220)

21.58.6000 Multifamily Residential Standards.

A. Applicability. RZC 21.58.6000 through RZC 21.58.6040 apply citywide to all multifamily development. (Ord. 3220)

21.58.6010 Residential Privacy Standards.

A. Purpose. The purpose of these standards is to uphold privacy and comfort in residential developments.

1. To ensure that new residential development provides adequate privacy and comfort for residents and their adjacent neighbors.

2. Privacy standards apply to all residential occupancy areas, as defined by the International Building Code or International Residential Code, as adopted in RMC Chapter 15.08, Building Code.

B. Applicability. RZC 21.58.6010 applies citywide to all multifamily structures.

C. References.

1. See RZC 21.58.3610, Facades.

2. See RZC 21.58.3650, Blank Wall Treatments.

3. See RZC 21.58.3630, Ground Floor Residential Uses.

D. Design Standards. The privacy standards in Table 21.58.6010.D apply to the shortest horizontal distance between the specified window and the specified property line, or to the window or wall of another unit in the same project.

1. Each unit in a project must meet these standards in each room.

2. The measurements indicated in the table below are “line-of-sight” measurements from window to window.

3. In the case where windows in one room are of equal size, either window may be selected by the builder as the largest window.

4. Measurements noted in Table 21.58.6010.D are for structures that are three or more stories in height unless otherwise noted.

5. Where Table 21.58.6010.D conflicts with regulations in RZC 21.58.3500, 21.58.3610, 21.58.3630 or 21.58.3650, regulations in those sections apply. Where conflicting with development standards in the zone, the most restrictive apply.

Table 21.58.6010.D. Privacy Standards

Primary Room Largest Window

On-Site

At Property Line

Secondary Room Largest Window

Blank Wall

Public Corridor

Front

Side

Interior Rear

Side Street

Primary Room

The Largest Window (Living Room, Dining Room)

(A)

45 feet

30 feet for 1 – 2 story buildings

(B)

30 feet

20 feet for 1 – 2 story buildings

(C)

15 feet

(D)

8 feet

(E)

Front Yard Setback

(F)

15 feet

(G)

15 feet

Front Street Setback

Secondary Room The Largest Window

(All Other Rooms)

(B)

30 feet

20 feet for 1 – 2 story buildings

(H)

15 feet

(I)

10 feet

(J)

0 feet

(K)

Front Yard Setback

(L)

Side Yard Setback

(M)

15 feet

Side Street Setback

Figure 21.58.6010.D
Example of Residential Privacy Standards

E. Alternative design compliance may be allowed if the alternative meets or exceeds the purpose of residential privacy standards or if mass timber construction is utilized and the structural capacity is in conflict with these requirements. (Ord. 3220)

21.58.6030 Minimum Residential Courtyard Dimensions.

A. Purpose. The courtyard provision is intended to create attractive and comfortable on-site open spaces for residents so they may enjoy outdoor living and recreational activities.

B. Applicability. RZC 21.58.6030 applies citywide to all multifamily and mixed-use structures.

C. References.

1. RZC 21.58.3300, Enclosed Courtyards.

2. See RZC Chapter 21.36, Open Space.

D. Design Standards.

1. Where courtyards are proposed to be used to meet common open space requirements, courtyard designs must conform to the standards as shown in Figure 21.58.6030.D.2.

2. Special incentive is provided to encourage courtyards that are open to the street. If 50 percent of the courtyard width is open to the street, the area that is contiguous with the courtyard, in the setback area, can be counted as usable open space. (See RZC 21.58.6030.D.2, Example #2.)

Figure 21.58.6030.D.2
Residential Courtyard Dimensions

3. Minimum Dimensions. Standards are as follows:

a. The minimum dimension (width and depth) of any courtyard must be no less than 1.0 times the tallest building or segment of building enclosing the courtyard (a ratio of 1.0:1.0) but is not required to exceed 55 feet (see Figure 21.58.6030.D.3.c.).

b. The height of the building wall must be measured from the courtyard elevation to the roof eaves of the enclosing building(s).

c. The courtyard dimension is a measurement of the usable open space between two building walls or to a property line. If balconies or corridors project into a courtyard, the dimension must be measured from the edge of the projecting balconies or corridors (see Figure 21.58.6030.D.3.c.).

Figure 21.58.6030.D.3.c
Example Residential Courtyard Elevations

d. If the enclosing walls terrace upward and back with succeeding stories, the courtyard dimension may be reduced but must not be less than 1.0 times the height of the ceiling of the lowest enclosing floor. (See Figure 21.58.6030.D.3.d.)

Figure 21.58.6030.D.3.d
Example Residential Courtyard Dimensions with Facade Step Back at Courtyard

E. Alternative design compliance may be granted to the minimum dimension requirement when the alternative meets or exceeds the purpose of the minimum residential courtyard dimensions. (Ord. 3220)

21.58.6040 Residential Access.

A. Purpose. The purpose of RZC 21.58.6040 is to ensure that orientation of the primary entrance is toward the street and adds interest to the building design.

B. Applicability. RZC 21.58.6040 applies citywide to all multifamily development.

C. Design Standards.

1. Front Entry Requirements. Every multifamily building must have a front entryway that meets the following standards:

a. Orientation. The primary entry must face the front property line or front yard unless otherwise allowed within the zoning district development standards.

b. Size. The entry must be at least eight feet wide.

c. Walkway. A decorative paved walkway, separated from and not crossing driveways, must be provided between the entry and the public pedestrian system.

d. The entry of ground floor units and ground floor foyers/lobbies along street fronts must be between two and four feet above the grade of the adjoining pedestrian system in order to provide visual interest in the yard abutting the street. This requirement does not apply to residential projects with ground floor commercial uses.

Figure 21.58.6040.C.1.a
Front Entry Requirements

New multifamily development must utilize half-flight-up entries off the street, giving privacy as well as a view of the street and sidewalk. ADA ramps, site grading, or other method must be used to provide for zero-step entry for a minimum of 20 percent of the street fronting units.

Figure 21.58.6040.C.1.b
Front Entry Examples

Where patios/private open spaces for units front the street (as opposed to front doors), walkways from the public sidewalk to the patio must also be included to provide a “front” to the unit along the street.

D. Alternative design compliance may be granted to the residential access requirement when the alternative meets or exceeds the purpose of the residential access provisions or where needed to implement universal design features. (Ord. 3220)

21.58.7000 Single-Family and Middle Housing Standards.

A. Purpose. The purpose of RZC 21.58.7000 is to maintain the vitality of the City’s residential areas by providing design standards for residential development.

1. To implement the goals and policies of the Community Development and Design Element and Housing Element of the Redmond Comprehensive Plan.

2. To establish residential design standards for all areas of the City that:

a. Provide variety and visual interest in new residential development.

b. Create engaging and active built environment that encourages residential buildings to be oriented towards the street or oriented towards a common open space feature or landscaped corridor.

c. Design homes that feature living space as the dominant feature of the street elevation rather than the garage or vehicle parking being the dominant feature.

d. Establish design standards for middle housing types that are equitable and comparable to design standards for detached single-family residences.

e. Support complete neighborhoods.

B. Applicability. RZC 21.58.7000 applies to all residential developments in the RA-5 and N-R zones.

1. All new residential development in the RA-5 and N-R zones, unless otherwise exempted by this chapter, must comply with the provisions of RZC 21.58.7010 through 21.58.7040 and RZC 21.58.0020.A through 21.58.0020.D.

2. Dwellings built prior to the adoption of residential design standards for the neighborhood in which the dwelling is located are not considered nonconforming dwellings and are not subject to the limitations on nonconforming structures set forth in RZC 21.04.5000, Legal Nonconforming Uses and Structures. (Ord. 3220)

21.58.7010 Variety and Visual Interest in Building Design.

A. Purpose. Provide variety and visual interest by using various combinations of building elements, features and treatments and variation in site design elements.

B. Applicability. See RZC 21.58.7000.B.

C. Design Standards.

1. Dwelling units with the same combination of features and treatments must not be located side by side with each other.

2. Architecture of new residential developments will be evaluated by the Administrator as a combination of at least four primary features per dwelling unit. The features may include:

a. Variation in color.

b. Variation of roof pitch, shape, and orientation between adjacent structures or dwelling units.

c. Variation in structure width of greater than five feet.

d. Variation in facade articulation and modulation.

e. Variation in facade materials.

f. Variation in visible window trim and mullions.

D. Alternative design compliance may be allowed for other building elements, treatments, features, or site designs which meet or exceed the purpose of RZC 21.58.7010. (Ord. 3220)

21.58.7020 Building Orientation.

A. Purpose. The purpose of RZC 21.58.7020 is to orient buildings to foster walkability, encourage social interaction, and promote housing diversity.

1. Provide active streetscapes that promote a more accessible, walkable, and enjoyable neighborhood experience for community members.

2. Incorporate features that facilitate social connections.

3. Support a variety of middle housing types.

4. Provide for design flexibility for a variety of middle housing types.

B. Applicability. See RZC 21.58.7000.B.

C. Design Standards.

1. Entrance Orientation.

a. The primary facade must be oriented toward the street or access corridor from which the lot is addressed.

b. Each building must incorporate a primary building entry or one or more private unit entries, such as a covered porch or recessed entry. Each entry must feature minimum weather protection of three feet by three feet.

c. Entrances of the units must be oriented toward the following:

i. The street or access corridor from which the lot is addressed; or

ii. A common open space feature such as a courtyard, plaza, or other landscape feature; or

iii. A landscaped corridor.

2. Garage Placement. Except for properties located on arterials, new dwelling units with attached garages facing the front street must be designed so that the garage is not the dominant feature as viewed from the street. Design techniques that meet the purpose of RZC 21.58.7020 may include, but are not limited to:

a. Setting the garage back a minimum of three feet from the front street elevation of the dwelling;

i. The front elevation of the first floor living space is equal or lesser distance to the front property line in comparison to the front elevation of the garage door and has a covered front exterior entry way that projects outward a minimum of three feet in comparison to the front elevation of the garage door; or

ii. The front elevation of the first floor living space is three feet or greater distance forward (closer to the front property line) from the front elevation of the garage door; or

iii. The front elevation of the second story of a proposed home is projected over the front elevation of the garage door by no less than three feet and is at minimum the width of the garage door and the front elevation of the first floor living space is equal or lesser distance to the front property line from the garage door. For the purposes of RZC 21.58.7020, the front street elevation may be measured from the forward-most column of a covered porch when the surface wall of the ground floor living space is recessed no more than four feet from the garage, and a second story projection of at least three feet is provided above the garage;

b. Recessing a garage under a second story, projecting roofline, deck, or balcony a minimum of three feet. The front street elevation of a side-loaded garage must have a minimum of one opening (i.e., window or door).

D. Alternative design compliance may be approved for other methods of building orientation that meet the purposes of RZC 21.58.7020 or that support the development of middle housing types. Alternative design compliance will not be allowed for garage placement standards. (Ord. 3220)

21.58.7030 Building Design, Proportionality and Massing.

A. Purpose. The purpose of RZC 21.58.7030 is to create visually engaging developments that enhance the urban landscape while maintaining a pedestrian-friendly environment.

1. Reduce the apparent size of large new development and expansions of existing development.

2. Provide variety and visual interest of building structures.

3. Maintain a human scale streetscape.

4. Provide visual relief from the massing and scale of built development through site design techniques such as centrally locating open space and preservation of mature trees.

B. Applicability. See RZC 21.58.7000.B.

C. Design Standards. The building must be modulated along the street at least every 30 feet. It must articulate into intervals that are compatible with adjacent structures with building elements such as entries, chimneys, roof lines, window patterns, horizontal modulation, offsets, different colors or ornamentation. (See Figure 21.58.7030).

Figure 21.58.7030
Modulation and Articulation

D. Alternative design compliance may be allowed if the alternative meets or exceeds the purpose of the standards. (Ord. 3220)

21.58.7040 Streets and Pathways in Residential Areas.

A. Purpose. The purpose of RZC 21.58.7040 is to make residential neighborhoods more walkable and connected.

1. Promote nonmotorized connections throughout the neighborhood along safe and scenic corridors, including pathways that are separated from arterial streets.

2. Provide connectivity within new developments and to adjacent developments, open space, and streets by discouraging the use of cul-de-sacs that inhibit connectivity and by discouraging the designation and construction of new private streets.

3. Design streets to implement traffic calming measures that support the pedestrian environment.

4. Reduce stormwater requirements by providing for natural-looking landscaped street edges that do not sharply define the private property from the public area and street and that contain landscaped drainage swales.

5. Ensure consistency with the neighborhood transportation connections maps.

B. Applicability. See RZC 21.58.7000.B.

C. Design Standards.

1. Where cul-de-sacs are utilized in new development, pedestrian connections to open space, adjacent streets, or adjacent developments must be provided at appropriate locations toward the end of the cul-de-sac. (See Figure 21.58.7040.C.1).

Figure 21.58.7040.C.1
Pedestrian Connections at Cul-de-Sacs

2. When there is more than a 600-foot distance between road connections in a new development, pedestrian connections must be provided at the end of cul-de-sacs or between lots to adjacent developments (where existing connections or undeveloped land exists) and/or through open space or trail linkages. (See Figure 21.58.7040.C.2).

Figure 21.58.7040.C.2
Pedestrian Connections Provided Between 600-Foot Distant Road Connections

3. At least one ingress and one egress connection must be provided to every adjacent trail, open space, or contiguous development(s).

4. Street trees must be provided on all new streets and must be selected from species that, at maturity, will provide a tree canopy along the street. Selected trees must not result in significant maintenance issues as determined by the Administrator.

5. General Requirements. General requirements for streets are found in RZC Appendix 2, Construction Specification and Design Standards for Streets and Access. New streets must be generally aligned as shown in the Transportation Connections Maps contained in the Neighborhood Element of the Redmond Comprehensive Plan and in the Transportation Master Plan in order to provide connectivity within the City.

D. Alternative design compliance may be allowed for minor modification in consideration of topography, existing vegetation, existing structures, or to align with other existing or planned streets in the neighborhood, provided the purpose of connecting streets and developments is achieved. (Ord. 3220)

21.62.010 Purpose.

The purpose of RZC Chapter 21.62 is to implement the vision of the Redmond Comprehensive Plan through the establishment of additional specific design standards for development projects located within the Town Center zone. (Ord. 3186; Ord. 3220)

21.62.020 Downtown Design Standards.

A. Purpose. The purpose of RZC 21.62.020 is to establish design criteria for properties in the Downtown neighborhood that will guide development to be attractive in appearance and functionally integrated, and to promote pedestrian and recreational activities within the neighborhood.

B. Repealed.

C. Repealed.

D. Repealed.

E. Repealed.

F. Repealed.

G. Repealed.

H. Repealed.

I. Town Center Zone.

1. Intent.

a. The Town Center zone consists of three subareas as shown and described below:

Figure 21.62.020S
Town Center Subareas

Town Center Subareas

i. The Town Center Mixed-Use area emphasizes a pedestrian-oriented and connected district that complements the transportation network of the Old Town zone and provides a progressive architectural transition from historic character of Old Town to the surrounding modern districts. Primary design features for the Town Center Mixed-Use zone include pedestrian-oriented uses along street frontages and sidewalk designs integrated into building architecture.

Figure 21.62.020T
Town Center

Town Center

ii. The Gateway Office area design concept features multilevel office buildings and an urban gateway facing SR 520. Building height, location, and architectural character are intended to create a strong urban perimeter and a varied urban texture connecting the site with the Downtown.

Figure 21.62.020U
Town Center

Town Center

iii. Bear Creek Retail area provides for auto-oriented retail tenants. The freestanding buildings with surface parking are distinct from the other two areas. However, architectural character, featured design elements, and pedestrian linkages incorporate a design commonality with the rest of the site.

b. Gateway to Downtown. The Gateway Office area functions as a gateway to the City from SR 520. Development in this area should complement the other components of this gateway, Marymoor Park, and Bear Creek, by providing attractive, interesting urban activity. Development should be consistent with the natural environment by minimizing glare, providing indirect lighting, avoiding intense signage, and providing a soft edge where the urban and natural environments meet.

c. Downtown Integration. Connection to existing roads, including landscape treatment, road surface, sidewalk size and placement, with respect to the existing grid system, streetscape, and character consistent with current standards and regulations. Development in the design area shall further City goals for the following subareas:

i. Leary Way. Leary Way between the Sammamish River and the BNSF right-of-way shall remain as a “green gateway” to the City of Redmond.

ii. Northern Boundary – Leary Way to 164th Avenue NE. Building siting will maintain continuity of building frontage in order to integrate new development with the Old Town zone.

iii. Northern Boundary – Leary Way to 170th Avenue NE.

A. This area should provide linkage capability between existing public roadways north of BNSF right-of-way and private roadways south of same. These new alignments should provide extension of the established visual corridors.

B. New connections on the site to existing north/south roads in this area should be compatible with the character of the existing older improvements.

C. Retail buildings located at the northern edge of the site within the Town Center Mixed-Use area will establish functional and visual continuity with the Downtown. The character of the new buildings will be compatible with older existing buildings.

iv. Bear Creek.

A. The edge along Bear Creek should be kept as a natural area, with uses limited to passive activity and trail/pathway connections.

B. Signage in this area shall be limited to traffic, safety, and directional information, or be consistent with the public recreational use of the area.

C. Structures consistent with and supporting passive use of this area may be allowed, and should be kept to a minimum.

v. Sammamish River.

A. The edge along the Sammamish River shall serve as an extension of existing activity on the Sammamish River Trail just north of this design area. Uses should include trail and pathway activities.

B. Signage shall be limited to traffic, safety, and directional information or be consistent with the public recreational use of the area.

C. Structures consistent with and supporting trail/pathway activities may be allowed, and should be kept to a minimum.

vi. BNSF Right-of-Way (ROW) – Pedestrian Crossings. Design and construct City-approved architectural/urban design features, walkways, and landscaping on 164th Avenue NE and other locations as determined to be necessary.

2. Design Criteria.

a. Architectural Guidelines.

i. Siting of Buildings. Buildings should be sited to enclose either a common space or provide enclosure to the street. All designs should appear as an integrated part of an overall site plan.

Figure 21.62.020V
Town Center

Town CenterTown Center

A. Encourage varieties of shapes, angles, and reliefs in the upper stories of structures over four stories.

B. Large buildings should avoid continuous, flat facades.

C. Avoid the use of false fronts.

D. The ground floor of buildings should provide pedestrian interest and activity. The use of arcades, colonnades, or awnings to provide pedestrian protection is encouraged. Column and bay spacing along street fronts should be provided no greater than 36 feet apart in order to maintain a pedestrian-oriented scale and rhythm.

Figure 21.62.020W
Town Center

Town Center

E. Building design should utilize similar or complementary building material, colors, and scale of adjoining Old Town.

F. Buildings and facades in the Town Center Mixed-Use area should be a combination of brick, stucco-like finishes, smooth-finished concrete, and architectural metals. Building facades in the Town Center Mixed-Use and Parkway Office areas should have a greater proportion of voids (windows) than solids (blank walls) on pedestrian levels. Buildings and facades in the Bear Creek retail area should be primarily masonry products with concrete and architectural metals used for detailing if desired. In all design, there should be emphasis upon the quality of detail and special form in window treatments, columns, eaves, cornices, lighting, signing, etc.

G. Buildings and the spaces between them should provide easy and open access to the external public areas or plazas.

H. The scale of all structures in relationship to other structures and spaces is important. The scale should be two to three stories in the retail core. Some variation in heights contributes to the variety and complexity of the environmental experience, and is encouraged.

I. The development of ground level viewpoints on each building level which take advantage of solar access and views of the site’s open spaces is encouraged.

J. Storefront design and materials should be unique while integrating into the architectural theme of the building facade of which they are a part.

ii. Building Entry. Orient building entrances to the street in a manner which provides easily identifiable and accessible pedestrian entryways. Highlight building entrances through landscape or architectural design features. Building entries should be designed in conjunction with the landscape treatment of pedestrian ways in the parking areas that directly relate to the entry.

iii. Public Art. Encourage public art in public areas of the Town Center zone, particularly in and around the Town Center Mixed-Use area.

iv. Building Orientation. Uses in the Town Center zone should be oriented externally as well as internally (as is applicable) by using outward-facing building facades, malls, entrances, and other design techniques.

A. Buildings in the Town Center Mixed-Use and Parkway Office areas should abut the sidewalks on at least one side and orient the primary entrance, or entrances, toward the street.

Figure 21.62.020X
Town Center Orientation to the Street

Town Center Building Orientation to the Street

v. Building Colors and Materials. Building colors and materials shall be selected to integrate with each other, other buildings in the Old Town zone, and other adjacent commercial areas, while allowing a richness of architectural expression for the various buildings.

A. Buildings should be constructed of materials that minimize light reflection and glare.

B. Care should be taken to avoid clashing colors on individual buildings and between adjacent buildings.

vi. Windows and Displays. Windows and display areas shall be located along pedestrian routes to enhance the pedestrian experience.

A. Storefronts should be visually open wherever practical. Stores should use enough glass so that the activity inside the store is obvious to the passerby. In all cases, merchandise should be easily visible to pedestrians.

B. Windows shall be provided on the street level in the Town Center Mixed-Use buildings rather than blank walls to encourage a visual and economic link between the business and passing pedestrians. A minimum of 60 percent of ground floor facades facing streets in the Town Center Mixed-Use area shall be in nonreflective, transparent glazing. Where windows cannot be provided, artwork in window boxes may be used with site plan review approval.

Figure 21.62.020Y
Town Center Outdoor Pedestrian Areas

Town Center Outdoor Pedestrian Areas

vii. Future Development Pads. Future development pads shall be consistent with the design standards and shall provide pedestrian-scale exterior features.

viii. Design Consistency. Each phase of the development and redevelopment of parcels throughout the zone shall be designed to be consistent with, but not necessarily the same as, the balance of the project architecture, including materials, colors, and general style.

ix. Pedestrian Features. Provide pedestrian-scale external features, including such items as window and glass display cases, street furniture, and covered walkways.

x. Outdoor Pedestrian Areas. The outdoor pedestrian areas shall include special paving treatments, landscaping, and seating areas.

A. Outdoor and ground floor areas shall be designed to encourage outdoor activities, such as vendors, art displays, seating areas, outdoor cafes, abutting retail activities, and other features of interest to pedestrians.

xi. Site Entrances. Entrances to buildings, open spaces, gathering areas, and clustered buildings in Town Center shall be emphasized with landscape treatments to strongly indicate the pedestrian orientation of these areas.

A. Architectural/urban design treatment of 166th Avenue NE shall encourage pedestrian circulation from the project to the Cleveland Street Retail area.

xii. Rooftops. Rooftops will be of a color that reduces glare and other types of visual impact on the adjacent residentially developed hillsides.

b. Transportation Guidelines.

i. Vehicular.

A. Street Configurations.

1. Streets that are above existing grade should be designed in a manner to reduce visual impact of pavement area, such as using landscaping or berms.

2. Encourage alignment of all streets to minimize the removal of all existing significant, healthy trees.

3. Streets shall not be wider than four travel lanes with the appropriate number of lanes at intersections between the zone and areas targeted for integration with the Downtown.

4. Vehicular circulation shall connect the various uses on the site to each other. Streets shall be designed to enhance viability of the project components.

B. Parking – Surface.

1. Where possible, locate parking behind buildings and away from areas of high public visibility. Landscape and screen surface parking areas visible to the public.

2. The size and location of parking areas should be minimized and related to the group of buildings served.

3. Visual impact of surface parking areas should be minimized from the SR 520 corridor.

4. Landscaping should be provided to screen surface parking areas and provide transition between the project and surrounding areas, particularly when viewed from SR 520, Leary Way, and adjacent hillsides.

Figure 21.62.020Z
Town Center Parking

Town Center Parking

5. Landscaped medians shall be provided where access and traffic allow.

6. Conflict between pedestrians and automobiles shall be minimized by designing streets to provide well-defined pedestrian walkways and crosswalks that reduce vehicle speeds.

7. Design and locate parking areas in a manner that will break up large areas of parking and encourage shared parking with existing Downtown uses.

8. Patrons of the retail center shall be allowed to use parking while patronizing other businesses in the Downtown. No rules, signage, or penalties shall be enacted by Town Center to preclude this parking allowance.

C. Parking – Structured. At least 50 percent of the parking provided for the entire site should occur in parking structures. The ratio of minimum structured parking shall be maintained for all phases of development of the Town Center Mixed-Use and the Parkway Office areas.

ii. Pedestrian.

A. Linkages.

1. Link proposed development to walkways, trails, and bicycle systems in the surrounding area by connecting and lining up directly to existing linkages, closing gaps, and treating crossings of barriers, such as the railroad, Bear Creek Parkway, and driveways, with special design treatment, minimizing barriers, designing with consistent materials, widths and locations, and providing safe, easy, and clearly identifiable access to and along the linkages. Safe, convenient, and attractive connections to Marymoor Park, the Sammamish River Trail, and the Bear Creek Trail system should be provided.

2. The sidewalk system shall be emphasized with landscape treatments to provide readily perceived pedestrian pathways through and around the Town Center zone.

B. Sidewalks.

1. When extending an existing sidewalk, the new walkway shall meet current standards and regulations where there is sufficient right-of-way, and be constructed of a material and dimension which are compatible with and improve upon the existing character.

2. Sidewalks shall meet similar standards to those of the approved pedestrian linkage system.

3. Paving of sidewalks and pedestrian crossings should be constructed of a uniform material that is compatible with the character of the zone. The private use of sidewalk rights-of-way areas may be appropriate for seasonal cafe seating or special displays.

4. Encourage alignment of new sidewalks to minimize the removal of all existing significant, healthy trees.

C. Arcades, Colonnades, and Canopies.

1. Buildings should be designed to provide for weather and wind protection at the ground level. Buildings fronting sidewalks shall provide pedestrian weather protection by way of arcades, colonnades, or canopies a minimum of 48 inches in depth. The elements should be complementary to the building’s design and design of contiguous weather protection elements on adjoining buildings. Materials and design should engender qualities of permanence and appeal.

2. Awnings or sunshades should be in keeping with the character of the building to which they are attached. Materials should be durable, long lasting, and require low maintenance. Back-lit awnings are discouraged.

D. Trails – Pedestrian. Special design treatment and appropriate safety features should be designed for pedestrian trail crossings at public rights-of-way and at the BNSF right-of-way tracks.

E. Trails – Bicycle. Facilities for parking and locking bicycles should be provided and be readily accessible from bicycle trails.

F. Plazas/Pedestrian Malls. Plazas, pedestrian malls, and other amenity open spaces shall be developed to promote outdoor activity and encourage pedestrian circulation between the Town Center zone and the balance of the Downtown.

c. Landscape Guidelines.

i. Urban Landscape Treatment. Building entries, primary vehicular entries, and building perimeters should be enhanced with landscaping which could include ornamental vines, groundcovers, shrubs, or trees selected for their screening, canopy, spatial enclosure, and seasonal variation.

ii. Site Furnishings. Benches, kiosks, signs, bollards, waste receptacles, street vending carts, water fountains, lighting standards, perch walls, sidewalks, pathways, trails, and special water features should be designed to be compatible elements of like materials and design.

iii. Perimeter Landscaping. Landscaping on the perimeter of the site will create a transition between the project and the surrounding area.

iv. Landscaping on Streets. Landscaping on streets should be simplified to allow adequate visibility from automobiles to businesses.

v. Trees, Plants, and Flowers. The use of potted plants and flowers as well as street trees is encouraged, but should not impede pedestrian traffic.

d. Open Space Guidelines.

i. Tree Retention and Open Space Landscaping. Preserve existing natural features, particularly healthy mature trees and stream courses.

A. Preserve 100 percent of all trees within the 44 acres of public access open space as identified in the Public Access Open Space Area Plan per Figure 21.62.020AA. This area includes the cluster of trees along the east side of Leary Way for the purpose of preserving the corridor’s green gateway image and the healthy trees along the Bear Creek and Sammamish River corridors. Trees that cannot be retained due to approved street or utility construction shall be replaced with native nursery stock of similar or like variety at a one-to-one ratio, with tree sizes in accordance with RZC 21.72.080, Tree Replacement, pursuant to a landscape plan approved in conjunction with site plan review. Trees removed as a result of construction activities, which are intended to be preserved, shall be replaced per RZC 21.72.080, Tree Replacement. Replacement trees shall be located in the immediate vicinity as is practical.

Figure 21.62.020AA
Town Center Public Access Open Space

Town Center Public Access Open Space

B. Minimize new grading in this area.

C. Install landscape screening between this open space area and adjacent parking areas.

D. Encourage passive recreation, including a walking trail, bicycle trail, seating and rest areas, pedestrian lighting, and site furnishings. Provide pedestrian connections to the Justice White House, Town Center Mixed-Use area, Marymoor Park, Sammamish River Trail system, and other open space areas.

E. The “soft edge” landscape treatment to the south of Town Center along Bear Creek shall provide for a true transition between the natural, riparian area of the creek to the more urban mixed-use retail area.

F. The informal nature of the west, south, and east portion of the site should be maintained by retaining native materials and random planting of compatible plant materials consistent with the Downtown neighborhood.

ii. Justice White House/Saturday Market. The areas around the Saturday Market and Justice White House shall be retained as open space. Areas at the Justice White House should encourage active and passive recreation. These areas should connect to other open spaces, trails, and the mixed-use retail area.

iii. Sammamish River. Open space shall be retained along the Sammamish River. The open space may be enhanced by:

A. Providing grade separation for trails at all appropriate and feasible locations;

B. Making connections to other open space zones;

C. An ongoing stormwater outflow monitoring program for private drainage systems. The monitoring program shall consider specific contaminants which may likely be present in the runoff and shall be revised periodically as appropriate.

iv. Bear Creek. Open space along Bear Creek shall be retained. The open space may be enhanced by:

A. Encouraging passive recreation areas and activities, and discouraging active recreation.

B. All stormwater swales and recharge areas should be integrated with the natural environment.

C. Protecting vegetation of the riparian habitat in this zone by limiting access to the creek to designated access points.

D. Providing connections to Marymoor Park, the Sammamish River, other open spaces, and Town Center.

E. Facilities within this area shall include a pedestrian pathway, bicycle path, equestrian trail when required, passive water access area, seating, and site furnishings.

F. An ongoing stormwater outflow monitoring program for private drainage systems. The monitoring program shall consider specific contaminants which may likely be present in the runoff, and shall be revised periodically as appropriate.

v. Public Access Open Space. Public access open space should be retained, enhanced, and made available for public use in this zone as shown in the Public Access Open Space Area Plan.

A. At least 44 acres shall be preserved by easement to the City or controlled by other methods that would permanently assure the open space to the City. This Downtown public access open space shall serve as a visual amenity and passive recreation open space.

vi. Open Space Acreage. Public access open space as shown in the Public Access Open Space Area Plan shall include a minimum of 44 acres. This will include natural areas inclusive of the floodway, and the areas around the Justice White House and the Saturday Market.

e. Lighting Plan.

i. A lighting plan and program which encourages nighttime pedestrian movement between the adjacent commercial areas, particularly Leary Way and 166th Avenue NE, shall be maintained.

ii. The height and design of street lighting should relate in scale to the pedestrian character of the area. The design of the light standards and luminaries should enhance the design theme. (Ord. 2803; Ord. 3114; Ord. 3220)

21.62.030 Overlake Metro Center Supplemental Design Standards.