Riverside Overlay District ROD

NOTES: | |
1 | Where storefront required is designated along a site on the ROD Standards Map, a storefront frontage or arcade frontage shall be provided and active frontage standards shall apply. |
2 | Where pedestrian access required is shown on the ROD Standards Map, as represented by its conceptual location, the final location and type of such access shall be determined during the site application process. Additional pedestrianways and walkways may be proposed by the applicant. |
3 | Where new street is shown on the ROD Standards Map, as represented by its potential conceptual location, the final location and street type designation shall be determined during the site application process. Additional new streets may be proposed by the applicant. |
Landscape and Furnishing Zone | A |
Pedestrian Clearway | B |
Transition Zone | C |
Required Width of Public Frontage | D |
STREET TYPES | ||||
|---|---|---|---|---|
Street Type A | Street Type B | Street Type C | Riverside Promenade | |
Distance from face of curb to build-to-line | 12 feet | 17 feet 6 inches | 6 feet | |
Landscape and furnishing zone minimum | 3 feet | 4 feet | 2 feet | |
Pedestrian clearway minimum | 6 feet | 6 feet | 4 feet | 10 feet |
Transition zone minimum | 2 feet | 5 feet | 0 feet | |
Street Type A | Street Type B | Street Type C | Riverside Promenade | ||||||
|---|---|---|---|---|---|---|---|---|---|
Private Frontage Types | Minimum Clear Glazing Area Required | Build-To-Zone (BTZ) Depth | Minimum Frontage Occupancy | Build-To-Zone (BTZ) Depth | Minimum Frontage Occupancy | Build-To-Zone (BTZ) Depth | Minimum Frontage Occupancy | Build-To-Zone (BTZ) Depth | Minimum Frontage Occupancy |
Storefront frontage1 | 50%3 | 15 feet | 80% | 15 feet | 80% | None | 0% | 15 feet | 60% |
Arcade frontage1 | 50%3 | 15 feet2 | 80% | 15 feet4 | 60% | None | 0% | 15 feet | 60% |
Hamlet frontage | 40%4 | 15 feet | 80% | 15 feet | 60% | None | 0% | 15 feet | 60% |
Stoop frontage | 30%5 | 15 feet | 80% | 15 feet | 60% | None | 0% | 15 feet | 40% |
Porch frontage | 30%5 | 15 feet | 80% | 15 feet | 60% | None | 0% | 15 feet | 40% |
Court frontage | 30%5 | 15 feet | 60% | 15 feet | 50% | None | 0% | 15 feet | 40% |
Mid-block frontage | 30%6 | X | X | X | X | None | 0% | X | X |
X | Not permitted |
NOTES: | |
1 | On streets designated on the Zoning Standards Map as "Storefront Required" a storefront frontage or arcade frontage is required. |
2 | Provided that the structural columns or piers are located within 5 feet of the build-to-line. |
3 | Minimum clear glazing area required between 2 feet and 8 feet above the sidewalk. Glazing can be 30% when used when storefront is not required. |
4 | Minimum clear glazing area required between 2 feet and 10 feet above the sidewalk. |
5 | Minimum clear glazing area required between 4 feet and 13 feet above the sidewalk. |
6 | Minimum clear glazing area required between 4 feet and 7 feet above the sidewalk. |
PERMITTED EDGING ELEMENTS2,3 | |||||
|---|---|---|---|---|---|
Private Frontage Types | Edge Structure EE-1 | Ornamental Fence EE-2 | Privacy Fence EE-3 | Planters EE-4 | Landscaped Edge EE-5 |
42 Inches Maximum Height | 72 Inches Maximum Height | 72 Inches Maximum Height | 72 Inches Maximum Height | 42 Inches Maximum Height | |
Storefront frontage1 | P | P | X | P | P |
Arcade frontage1 | P | P | X | P | P |
Hamlet frontage | P | P | X | P | P |
Stoop frontage | P | P | X | P | P |
Porch frontage | P | P | X | X | P |
Court frontage | P | P | X | P | P |
Mid-block frontage | P | P | X | P | P |
X | Not permitted |
NOTES: | |
1 | On streets designated on the Zoning Standards Map as "Storefront Required" a storefront frontage or arcade frontage is required. |
2 | Combination of permitted edging elements can be used at the approval of the Planning Board. |
3 | Chain link, barbed wire, razor, chicken wire, stockade fencing, and split rail fencing shall be prohibited. |
Use | District | ||||||
|---|---|---|---|---|---|---|---|
RO-1 | RO-2 | RO-3 | RO-4 | RO-5 | RO-6 | RO-7 | |
MIXED USE | |||||||
Mixed-use building | P | P | P | P | X | P | X |
Live-work unit | P | P | P | P | X | X | X |
RETAIL | |||||||
Retail | P | P | P | X | X | P | X |
Restaurant | P | P | P | X | X | P | X |
Drive-through | X | X | X | X | X | X | X |
OFFICE | |||||||
Office | P | P | P | P | X | X | X |
Medical office | P | P | P | P | X | X | X |
Professional service | P | P | P | P | X | X | X |
Business incubators | P | P | P | X | X | X | X |
RESIDENTIAL1 | |||||||
Home occupation/home prof. office | P | P | P | P | P | P | X |
Single-family | X | X | X | X | P | X | X |
Townhome | P | P | P | P | X | P | X |
Two-family | P | P | P | P | P | P | X |
Granny-flat4 | X | X | X | X | P | X | X |
Multiple dwelling | P | P | P | P | X | P | X |
Multifamily residence | P | P | P | P | X | X | X |
CULTURAL | |||||||
Theater | P | P | P | X | X | X | X |
Museum | P | P | P | P | X | P | X |
HOSPITALITY | |||||||
Hotel | P | P | P | X | X | P | X |
Bed-and-breakfast | P | P | P | P | P | P | X |
Residential care facility | P | P | P | P | X | P | X |
RECREATION/EDUCATION | |||||||
Recreational business | P | P | P | P | X | P | P |
Educational use | P | P | P | P | P | P | X |
Camping grounds | X | X | X | X | X | X | P |
RELIGIOUS/CIVIC | |||||||
Houses of worship | P | P | P | P | X | P | X |
Library | P | P | P | P | X | X | X |
SPECIAL WATERFRONT | |||||||
Marina | P | X | X | X | X | P | X |
LIGHT INDUSTRIAL | |||||||
Artisan production facilities2 | P | P | P | P | X | P | X |
Research and development facility | P | P | P | P | X | X | X |
Data information center | P | P | P | P | X | X | X |
Document/misc. storage | P | P | P | P | X | X | X |
Renewable energy facilities | P | P | P | P | X | P | X |
Agricultural use | P | P | P | P | P | P | X |
Animal husbandry | X | X | X | X | X | X | X |
PARKING FACILITIES | |||||||
Parking structure | P | P | P | P | X | P | X |
Parking lot | P | P | P | P | X | P | P |
ADULT ENTERTAINMENT3 | |||||||
Adult entertainment use | X | X | X | X | X | X | X |
INFRASTRUCTURE | |||||||
Utilities | P | P | P | P | P | P | X |
Wastewater treatment plant | P | P | P | P | P | P | X |
P | Permitted |
X | Prohibited |
NOTES: | |
1 | Private dwelling units are prohibited within the private frontage area on the first floor of storefront frontages. |
2 | Where storefronts are required, artisan production shall provide a storefront for a depth of a minimum of 30 feet. |
3 | As defined in § 330-162.17 of the Town of Southampton Zoning Ordinance. |
4 | Only permitted as an accessory to existing single-family home. |
ROD Base Requirements | Riverside Incentive Bonus 1 RIB-1 | Riverside Incentive Bonus 2 RIB-2 | ||
|---|---|---|---|---|
Site Frontage Minimum (feet) | All Districts | 75 | 150 | 300 |
Site Area Minimum (square feet) | 7,500 | 15,000 | 60,000 | |
Building Height | RO-1 | 2 stories min (30 feet streetwall height min2) 3 stories and 35 feet max | 3.5 stories max 45 feet max | 4.5 stories max 55 feet max |
RO-2 | 2 stories min, 3 stories and 35 feet max | 3.5 stories max 45 feet max | 4 stories max 50 feet max | |
RO-3 | 16 feet streetwall height min, 2.5 stories and 35 feet max3 | 3 stories max 40 feet max | 3.5 stories max4 45 feet max | |
RO-4 | 16 feet streetwall height min 2 stories, and 32 feet max | 2.5 stories max 35 feet max | No bonus available | |
RO-5 | 2 stories, and 32 feet max | 2.5 stories max 35 feet max | No bonus available | |
RO-6 | 16 feet streetwall height min 2 stories, and 32 feet max | 2.5 stories 35 feet max | 3.5 stories max 40 feet max | |
Parking | All Districts | ROD minimum requirements | Increased shared access or new streets | |
Bicycle Parking | ROD minimum requirements | RIB-1 and RIB-2 minimum requirements (§ 330-410J) | ||
NOTES: | |
1 | All setbacks in RO-5 District shall comply with the setbacks prescribed by the underlying zoning. |
2 | Base height; if minimum streetwall height required, needs to comply for at least 30% of frontage. |
3 | Or max height of the underlying zoning, whichever is greater. |
4 | Except where the underlying zoning is LI-40, then a maximum of 4 stories is permitted. |



Use | Proposed ROD Parking Requirements |
|---|---|
Retail Uses | |
Retail | 3 spaces per 1,000 square feet |
Restaurant | 3 spaces per 1,000 square feet |
Office Uses | |
Office/professional service/business incubator | 2 spaces per 1,000 square feet |
Medical office | 2 spaces per 1,000 square feet |
Residential | |
Residential | 1 space per unit |
Hospitality | |
Hotel | 1 space per unit |
Bed-and-breakfast | 1 space per unit |
Residential care facility | 1 space per 5,000 square feet |
Recreation and Civic Uses | |
Theater | 2 spaces per 1,000 square feet |
Library | 1 space per 1,000 square feet |
School/educational use | 1 space per 1,000 square feet |
Recreational business | 1 space per 1,000 square feet |
Light Industrial and Warehouse | |
Artisan production | 2 spaces per 1,000 square feet |
Research and development | 2 spaces per 1,000 square feet |
Document/misc. storage | 1 space per 5,000 square feet |
Data information center | 1 space per 5,000 square feet |
BASE | RIVERSIDE INCENTIVE BONUS (RIB) 1, 2 | ||
|---|---|---|---|
ALL DISTRICTS | Reduce Impacts to Water Resources | All new development within ROD must connect to an approved wastewater treatment facility that provides advanced nitrogen treatment reduction capabilities. | |
Maximum 15% of the site may be planted with fertilizer dependent vegetation; limiting landscaped areas that will require irrigation, fertilization and pesticide applications by retaining natural vegetation to the maximum extent possible and revegetating areas that have been disturbed during the construction process but will remain undeveloped with native or well-adapted noninvasive species | |||
Reduce Water Use [See § 330-410I(2)] | Reduce indoor water use 20% below baseline (use of low flow fixtures, fittings and appliances) | ||
Outdoor Potable Water Consumption [See § 330-410I(3)] | Reduce potable water consumption for outdoor landscape irrigation by 50% from a calculated midsummer baseline case (use of plant species, density and microclimate; irrigation efficiency; water reuse) | ||
Heat Island Reduction [See § 330-410I(4)] | Heat island reduction for 50% of the nonroof site hardscape providing increased shade and permeable coverage | ||
Install "green" roof for at least 50% of roof area or use roofing materials with low solar reflectance index for 75% of roof | |||
Provision of Open Space Requirement (See § 330-409B) | Provide 10% of development site area as public open space | ||
Provide 5% of development site area requirement as private open space | |||
Stormwater Management | Use of pretreatment of stormwater runoff prior to infiltration using "green infrastructure" practices such as vegetated swales, filter strips, rain gardens, green roofs, other best management practices (BMPs) in accordance with the New York State Stormwater Management Design Manual and the Suffolk County Planning Commission Managing Stormwater Guide. | ||
Reduce Carbon Emissions | Provide public frontages to encourage pedestrian activity | ||
Provide bicycle parking racks for residents, visitors and employees (See § 330-410J.) | |||
Provide parking as required (for base requirements) | Provide PMP and increase car sharing (for RIB-1 and RIB-2) | ||
Clearing | Contribution to a Riverside Fair Share Mitigation Fund to advance benefits to natural vegetation in the central pine barrens | ||
Ensure that existing quality contiguous natural pine barrens habitat is retained in the study area through design | |||
Advance wastewater treatment opportunities, nitrogen removal, stormwater management, other technologies that will improve water quality in the pine barrens and resultant water quality in the Peconic Bay system, consistent with the legislative findings and intent of Article 57 | |||
Fixtures, Fittings and Appliances | Current Baseline |
|---|---|
National Efficiency Baselines for Commercial Water-Using Fixtures, Fittings and Appliances1 | |
Commercial toilets | 1.6 gpf2 except blow-out fixtures: 3.5-gpf |
Commercial urinals | 1.0 gpf |
Commercial lavatory (restroom) faucets | 2.2 gpm at 60 psi; private applications only (hotel-motel guest rooms) |
0.5 gpm at 60 psi3 all others except private applications | |
0.25 gallons per cycle for metering faucets | |
Commercial pre-rinse spray valves (for food service applications) | Flow rate ≤ 1.6 gpm (no pressure specified; no performance requirement) |
National Efficiency Baselines for Residential Water-Using Fixtures, Fittings and Appliances1 | |
Residential toilets | 1.6 gpf4 |
Residential lavatory (bathroom) faucets | 2.2 gpm at 60 psi |
Residential kitchen faucet | |
Residential showerheads | 2.5 gpm at 80 psi per shower stall5 |
NOTES: | |
1 | Adapted from information developed and summarized by the U.S. EPA Office of Water. |
2 | EPAct 1992 standard for toilets applies to both commercial and residential models. |
3 | In addition to EPAct requirements, the American Society of Mechanical Engineers standard for public lavatory faucets is 0.5 gpm at 60 psi (ASME A112.18.1-2005). This maximum has been incorporated into the National Uniform Plumbing Code and the International Plumbing Code. |
4 | EPAct 1992 standard for toilets applies to both commercial and residential models. |
5 | Residential shower compartment (stall) in dwelling units: The total allowable flow rate from all flowing showerheads at any given time, including rain systems, waterfalls, body sprays, body spas, and jets, shall be limited to the allowable showerhead flow rate as specified above (2.5 gpm) per shower compartment, where the floor area of the shower compartment is less than 2,500 square inches For each increment of 2,500 square inches of floor area thereafter or part thereof, an additional showerhead with total allowable flow rate from all flowing devices equal to or less than the allowable flow rate as specified above shall be allowed. Exception: Showers that emit recirculated nonpotable water originating from within the shower compartment while operating are allowed to exceed the maximum as long as the total potable water flow does not exceed the flow rate as specified above. |
Roof Type | Slope | SRI |
|---|---|---|
Low-sloped roof | ≤ 2:12 | 78 |
Steep-sloped roof | > 2:12 | 29 |
Street ID | Street Type | RO-1 | RO-2 | RO-3 | RO-4 | RO-5 | RO-6 |
|---|---|---|---|---|---|---|---|
AV-1 | Avenue1 | P | P | P | X | X | P |
AV-2 | Avenue | P | P | P | X | X | X |
AV-3 | Avenue | P | P | P | P | P | P |
AV-4 | Avenue | P | P | P | P | P | P |
ST-1 | Street | P | P | P | P | P | P |
ST-2 | Street | P | P | P | P | P | P |
ST-3 | Street | P | P | P | P | P | P |
ST-4 | Street | P | P | P | P | X | P |
LN-1 | Lane | P | P | P | P | P | P |
LN-2 | Lane | P | P | P | P | P | P |
LN-3 | Lane | P | P | P | P | P | P |
LN-4 | Lane | P | P | P | P | P | P |
P | Permitted |
X | Prohibited |
NOTES: | |
1 | Permitted only as existing street. |
Type ID | Type | RO-1 | RO-2 | RO-3 | RO-4 | RO-5 | RO-6 | RO-7 |
|---|---|---|---|---|---|---|---|---|
PW-1 | Pedestrian way | P | P | P | P | P | P | P |
PW-2 | Pedestrian way | P | P | P | P | P | P | P |
RP-1 | Riverside promenade | P | X | X | X | X | P | P |
RP-2 | Riverside promenade | P | X | X | X | X | P | P |
RP-3 | Riverside promenade | P | X | X | X | X | P | P |
WK-1 | Boardwalk | P | P | P | P | P | P | P |
WK-2 | Walkway | P | P | P | P | P | P | P |
P | Permitted |
X | Prohibited |










Riverside Overlay District ROD

NOTES: | |
1 | Where storefront required is designated along a site on the ROD Standards Map, a storefront frontage or arcade frontage shall be provided and active frontage standards shall apply. |
2 | Where pedestrian access required is shown on the ROD Standards Map, as represented by its conceptual location, the final location and type of such access shall be determined during the site application process. Additional pedestrianways and walkways may be proposed by the applicant. |
3 | Where new street is shown on the ROD Standards Map, as represented by its potential conceptual location, the final location and street type designation shall be determined during the site application process. Additional new streets may be proposed by the applicant. |
Landscape and Furnishing Zone | A |
Pedestrian Clearway | B |
Transition Zone | C |
Required Width of Public Frontage | D |
STREET TYPES | ||||
|---|---|---|---|---|
Street Type A | Street Type B | Street Type C | Riverside Promenade | |
Distance from face of curb to build-to-line | 12 feet | 17 feet 6 inches | 6 feet | |
Landscape and furnishing zone minimum | 3 feet | 4 feet | 2 feet | |
Pedestrian clearway minimum | 6 feet | 6 feet | 4 feet | 10 feet |
Transition zone minimum | 2 feet | 5 feet | 0 feet | |
Street Type A | Street Type B | Street Type C | Riverside Promenade | ||||||
|---|---|---|---|---|---|---|---|---|---|
Private Frontage Types | Minimum Clear Glazing Area Required | Build-To-Zone (BTZ) Depth | Minimum Frontage Occupancy | Build-To-Zone (BTZ) Depth | Minimum Frontage Occupancy | Build-To-Zone (BTZ) Depth | Minimum Frontage Occupancy | Build-To-Zone (BTZ) Depth | Minimum Frontage Occupancy |
Storefront frontage1 | 50%3 | 15 feet | 80% | 15 feet | 80% | None | 0% | 15 feet | 60% |
Arcade frontage1 | 50%3 | 15 feet2 | 80% | 15 feet4 | 60% | None | 0% | 15 feet | 60% |
Hamlet frontage | 40%4 | 15 feet | 80% | 15 feet | 60% | None | 0% | 15 feet | 60% |
Stoop frontage | 30%5 | 15 feet | 80% | 15 feet | 60% | None | 0% | 15 feet | 40% |
Porch frontage | 30%5 | 15 feet | 80% | 15 feet | 60% | None | 0% | 15 feet | 40% |
Court frontage | 30%5 | 15 feet | 60% | 15 feet | 50% | None | 0% | 15 feet | 40% |
Mid-block frontage | 30%6 | X | X | X | X | None | 0% | X | X |
X | Not permitted |
NOTES: | |
1 | On streets designated on the Zoning Standards Map as "Storefront Required" a storefront frontage or arcade frontage is required. |
2 | Provided that the structural columns or piers are located within 5 feet of the build-to-line. |
3 | Minimum clear glazing area required between 2 feet and 8 feet above the sidewalk. Glazing can be 30% when used when storefront is not required. |
4 | Minimum clear glazing area required between 2 feet and 10 feet above the sidewalk. |
5 | Minimum clear glazing area required between 4 feet and 13 feet above the sidewalk. |
6 | Minimum clear glazing area required between 4 feet and 7 feet above the sidewalk. |
PERMITTED EDGING ELEMENTS2,3 | |||||
|---|---|---|---|---|---|
Private Frontage Types | Edge Structure EE-1 | Ornamental Fence EE-2 | Privacy Fence EE-3 | Planters EE-4 | Landscaped Edge EE-5 |
42 Inches Maximum Height | 72 Inches Maximum Height | 72 Inches Maximum Height | 72 Inches Maximum Height | 42 Inches Maximum Height | |
Storefront frontage1 | P | P | X | P | P |
Arcade frontage1 | P | P | X | P | P |
Hamlet frontage | P | P | X | P | P |
Stoop frontage | P | P | X | P | P |
Porch frontage | P | P | X | X | P |
Court frontage | P | P | X | P | P |
Mid-block frontage | P | P | X | P | P |
X | Not permitted |
NOTES: | |
1 | On streets designated on the Zoning Standards Map as "Storefront Required" a storefront frontage or arcade frontage is required. |
2 | Combination of permitted edging elements can be used at the approval of the Planning Board. |
3 | Chain link, barbed wire, razor, chicken wire, stockade fencing, and split rail fencing shall be prohibited. |
Use | District | ||||||
|---|---|---|---|---|---|---|---|
RO-1 | RO-2 | RO-3 | RO-4 | RO-5 | RO-6 | RO-7 | |
MIXED USE | |||||||
Mixed-use building | P | P | P | P | X | P | X |
Live-work unit | P | P | P | P | X | X | X |
RETAIL | |||||||
Retail | P | P | P | X | X | P | X |
Restaurant | P | P | P | X | X | P | X |
Drive-through | X | X | X | X | X | X | X |
OFFICE | |||||||
Office | P | P | P | P | X | X | X |
Medical office | P | P | P | P | X | X | X |
Professional service | P | P | P | P | X | X | X |
Business incubators | P | P | P | X | X | X | X |
RESIDENTIAL1 | |||||||
Home occupation/home prof. office | P | P | P | P | P | P | X |
Single-family | X | X | X | X | P | X | X |
Townhome | P | P | P | P | X | P | X |
Two-family | P | P | P | P | P | P | X |
Granny-flat4 | X | X | X | X | P | X | X |
Multiple dwelling | P | P | P | P | X | P | X |
Multifamily residence | P | P | P | P | X | X | X |
CULTURAL | |||||||
Theater | P | P | P | X | X | X | X |
Museum | P | P | P | P | X | P | X |
HOSPITALITY | |||||||
Hotel | P | P | P | X | X | P | X |
Bed-and-breakfast | P | P | P | P | P | P | X |
Residential care facility | P | P | P | P | X | P | X |
RECREATION/EDUCATION | |||||||
Recreational business | P | P | P | P | X | P | P |
Educational use | P | P | P | P | P | P | X |
Camping grounds | X | X | X | X | X | X | P |
RELIGIOUS/CIVIC | |||||||
Houses of worship | P | P | P | P | X | P | X |
Library | P | P | P | P | X | X | X |
SPECIAL WATERFRONT | |||||||
Marina | P | X | X | X | X | P | X |
LIGHT INDUSTRIAL | |||||||
Artisan production facilities2 | P | P | P | P | X | P | X |
Research and development facility | P | P | P | P | X | X | X |
Data information center | P | P | P | P | X | X | X |
Document/misc. storage | P | P | P | P | X | X | X |
Renewable energy facilities | P | P | P | P | X | P | X |
Agricultural use | P | P | P | P | P | P | X |
Animal husbandry | X | X | X | X | X | X | X |
PARKING FACILITIES | |||||||
Parking structure | P | P | P | P | X | P | X |
Parking lot | P | P | P | P | X | P | P |
ADULT ENTERTAINMENT3 | |||||||
Adult entertainment use | X | X | X | X | X | X | X |
INFRASTRUCTURE | |||||||
Utilities | P | P | P | P | P | P | X |
Wastewater treatment plant | P | P | P | P | P | P | X |
P | Permitted |
X | Prohibited |
NOTES: | |
1 | Private dwelling units are prohibited within the private frontage area on the first floor of storefront frontages. |
2 | Where storefronts are required, artisan production shall provide a storefront for a depth of a minimum of 30 feet. |
3 | As defined in § 330-162.17 of the Town of Southampton Zoning Ordinance. |
4 | Only permitted as an accessory to existing single-family home. |
ROD Base Requirements | Riverside Incentive Bonus 1 RIB-1 | Riverside Incentive Bonus 2 RIB-2 | ||
|---|---|---|---|---|
Site Frontage Minimum (feet) | All Districts | 75 | 150 | 300 |
Site Area Minimum (square feet) | 7,500 | 15,000 | 60,000 | |
Building Height | RO-1 | 2 stories min (30 feet streetwall height min2) 3 stories and 35 feet max | 3.5 stories max 45 feet max | 4.5 stories max 55 feet max |
RO-2 | 2 stories min, 3 stories and 35 feet max | 3.5 stories max 45 feet max | 4 stories max 50 feet max | |
RO-3 | 16 feet streetwall height min, 2.5 stories and 35 feet max3 | 3 stories max 40 feet max | 3.5 stories max4 45 feet max | |
RO-4 | 16 feet streetwall height min 2 stories, and 32 feet max | 2.5 stories max 35 feet max | No bonus available | |
RO-5 | 2 stories, and 32 feet max | 2.5 stories max 35 feet max | No bonus available | |
RO-6 | 16 feet streetwall height min 2 stories, and 32 feet max | 2.5 stories 35 feet max | 3.5 stories max 40 feet max | |
Parking | All Districts | ROD minimum requirements | Increased shared access or new streets | |
Bicycle Parking | ROD minimum requirements | RIB-1 and RIB-2 minimum requirements (§ 330-410J) | ||
NOTES: | |
1 | All setbacks in RO-5 District shall comply with the setbacks prescribed by the underlying zoning. |
2 | Base height; if minimum streetwall height required, needs to comply for at least 30% of frontage. |
3 | Or max height of the underlying zoning, whichever is greater. |
4 | Except where the underlying zoning is LI-40, then a maximum of 4 stories is permitted. |



Use | Proposed ROD Parking Requirements |
|---|---|
Retail Uses | |
Retail | 3 spaces per 1,000 square feet |
Restaurant | 3 spaces per 1,000 square feet |
Office Uses | |
Office/professional service/business incubator | 2 spaces per 1,000 square feet |
Medical office | 2 spaces per 1,000 square feet |
Residential | |
Residential | 1 space per unit |
Hospitality | |
Hotel | 1 space per unit |
Bed-and-breakfast | 1 space per unit |
Residential care facility | 1 space per 5,000 square feet |
Recreation and Civic Uses | |
Theater | 2 spaces per 1,000 square feet |
Library | 1 space per 1,000 square feet |
School/educational use | 1 space per 1,000 square feet |
Recreational business | 1 space per 1,000 square feet |
Light Industrial and Warehouse | |
Artisan production | 2 spaces per 1,000 square feet |
Research and development | 2 spaces per 1,000 square feet |
Document/misc. storage | 1 space per 5,000 square feet |
Data information center | 1 space per 5,000 square feet |
BASE | RIVERSIDE INCENTIVE BONUS (RIB) 1, 2 | ||
|---|---|---|---|
ALL DISTRICTS | Reduce Impacts to Water Resources | All new development within ROD must connect to an approved wastewater treatment facility that provides advanced nitrogen treatment reduction capabilities. | |
Maximum 15% of the site may be planted with fertilizer dependent vegetation; limiting landscaped areas that will require irrigation, fertilization and pesticide applications by retaining natural vegetation to the maximum extent possible and revegetating areas that have been disturbed during the construction process but will remain undeveloped with native or well-adapted noninvasive species | |||
Reduce Water Use [See § 330-410I(2)] | Reduce indoor water use 20% below baseline (use of low flow fixtures, fittings and appliances) | ||
Outdoor Potable Water Consumption [See § 330-410I(3)] | Reduce potable water consumption for outdoor landscape irrigation by 50% from a calculated midsummer baseline case (use of plant species, density and microclimate; irrigation efficiency; water reuse) | ||
Heat Island Reduction [See § 330-410I(4)] | Heat island reduction for 50% of the nonroof site hardscape providing increased shade and permeable coverage | ||
Install "green" roof for at least 50% of roof area or use roofing materials with low solar reflectance index for 75% of roof | |||
Provision of Open Space Requirement (See § 330-409B) | Provide 10% of development site area as public open space | ||
Provide 5% of development site area requirement as private open space | |||
Stormwater Management | Use of pretreatment of stormwater runoff prior to infiltration using "green infrastructure" practices such as vegetated swales, filter strips, rain gardens, green roofs, other best management practices (BMPs) in accordance with the New York State Stormwater Management Design Manual and the Suffolk County Planning Commission Managing Stormwater Guide. | ||
Reduce Carbon Emissions | Provide public frontages to encourage pedestrian activity | ||
Provide bicycle parking racks for residents, visitors and employees (See § 330-410J.) | |||
Provide parking as required (for base requirements) | Provide PMP and increase car sharing (for RIB-1 and RIB-2) | ||
Clearing | Contribution to a Riverside Fair Share Mitigation Fund to advance benefits to natural vegetation in the central pine barrens | ||
Ensure that existing quality contiguous natural pine barrens habitat is retained in the study area through design | |||
Advance wastewater treatment opportunities, nitrogen removal, stormwater management, other technologies that will improve water quality in the pine barrens and resultant water quality in the Peconic Bay system, consistent with the legislative findings and intent of Article 57 | |||
Fixtures, Fittings and Appliances | Current Baseline |
|---|---|
National Efficiency Baselines for Commercial Water-Using Fixtures, Fittings and Appliances1 | |
Commercial toilets | 1.6 gpf2 except blow-out fixtures: 3.5-gpf |
Commercial urinals | 1.0 gpf |
Commercial lavatory (restroom) faucets | 2.2 gpm at 60 psi; private applications only (hotel-motel guest rooms) |
0.5 gpm at 60 psi3 all others except private applications | |
0.25 gallons per cycle for metering faucets | |
Commercial pre-rinse spray valves (for food service applications) | Flow rate ≤ 1.6 gpm (no pressure specified; no performance requirement) |
National Efficiency Baselines for Residential Water-Using Fixtures, Fittings and Appliances1 | |
Residential toilets | 1.6 gpf4 |
Residential lavatory (bathroom) faucets | 2.2 gpm at 60 psi |
Residential kitchen faucet | |
Residential showerheads | 2.5 gpm at 80 psi per shower stall5 |
NOTES: | |
1 | Adapted from information developed and summarized by the U.S. EPA Office of Water. |
2 | EPAct 1992 standard for toilets applies to both commercial and residential models. |
3 | In addition to EPAct requirements, the American Society of Mechanical Engineers standard for public lavatory faucets is 0.5 gpm at 60 psi (ASME A112.18.1-2005). This maximum has been incorporated into the National Uniform Plumbing Code and the International Plumbing Code. |
4 | EPAct 1992 standard for toilets applies to both commercial and residential models. |
5 | Residential shower compartment (stall) in dwelling units: The total allowable flow rate from all flowing showerheads at any given time, including rain systems, waterfalls, body sprays, body spas, and jets, shall be limited to the allowable showerhead flow rate as specified above (2.5 gpm) per shower compartment, where the floor area of the shower compartment is less than 2,500 square inches For each increment of 2,500 square inches of floor area thereafter or part thereof, an additional showerhead with total allowable flow rate from all flowing devices equal to or less than the allowable flow rate as specified above shall be allowed. Exception: Showers that emit recirculated nonpotable water originating from within the shower compartment while operating are allowed to exceed the maximum as long as the total potable water flow does not exceed the flow rate as specified above. |
Roof Type | Slope | SRI |
|---|---|---|
Low-sloped roof | ≤ 2:12 | 78 |
Steep-sloped roof | > 2:12 | 29 |
Street ID | Street Type | RO-1 | RO-2 | RO-3 | RO-4 | RO-5 | RO-6 |
|---|---|---|---|---|---|---|---|
AV-1 | Avenue1 | P | P | P | X | X | P |
AV-2 | Avenue | P | P | P | X | X | X |
AV-3 | Avenue | P | P | P | P | P | P |
AV-4 | Avenue | P | P | P | P | P | P |
ST-1 | Street | P | P | P | P | P | P |
ST-2 | Street | P | P | P | P | P | P |
ST-3 | Street | P | P | P | P | P | P |
ST-4 | Street | P | P | P | P | X | P |
LN-1 | Lane | P | P | P | P | P | P |
LN-2 | Lane | P | P | P | P | P | P |
LN-3 | Lane | P | P | P | P | P | P |
LN-4 | Lane | P | P | P | P | P | P |
P | Permitted |
X | Prohibited |
NOTES: | |
1 | Permitted only as existing street. |
Type ID | Type | RO-1 | RO-2 | RO-3 | RO-4 | RO-5 | RO-6 | RO-7 |
|---|---|---|---|---|---|---|---|---|
PW-1 | Pedestrian way | P | P | P | P | P | P | P |
PW-2 | Pedestrian way | P | P | P | P | P | P | P |
RP-1 | Riverside promenade | P | X | X | X | X | P | P |
RP-2 | Riverside promenade | P | X | X | X | X | P | P |
RP-3 | Riverside promenade | P | X | X | X | X | P | P |
WK-1 | Boardwalk | P | P | P | P | P | P | P |
WK-2 | Walkway | P | P | P | P | P | P | P |
P | Permitted |
X | Prohibited |