Subdivision Regulations
DESCRIPTION | REMARKS | ||
1 | Received fees. | ||
2 | Ten copies of plat (at a scale of not more than 1" = 100'). | ||
3 | Name of Subdivision. | ||
4 | Location of property with respect to surrounding property and streets. | ||
5 | Location by township, section, town and range. | ||
6 | Names of all adjoining property owners, or names of adjoining developers. | ||
7 | Name of adjoining subdivisions. | ||
8 | Location and names of adjoining streets. | ||
9 | Location of corporation line, if applicable. | ||
10 | Location and dimensions of all boundary lines of the property in feet and decimals of a foot. | ||
11 | Vicinity sketch. | ||
12 | Indication of zoning. | ||
13 | Location of existing easements. | ||
14 | Location of existing water bodies, streams, and other pertinent features such as railroads, buildings, parks, cemeteries, drainage ditches, bridges, etc. | ||
15 | Locations, dimensions and areas of all proposed or existing lots. | ||
16 | Location and dimensions of all property proposed to be set aside for park or playground use, or other public or private reservation, with designation of the purpose thereof, and conditions, if any, of the dedication or reservation. | ||
DESCRIPTION | REMARKS |
17 | Date of plat. | ||
18 | Scale of plat. | ||
19 | North arrow. | ||
20 | Data from which the location, bearing and length of all lines can be determined and reproduced on the ground. | ||
21 | Names of new streets as approved by the Planning Commission. | ||
22 | Indication of the use of any lot and all uses other than residential. | ||
23 | Lots consecutively numbered. | ||
24 | Approximate dimensions of lots, including lot area. | ||
25 | Front building setback lines. | ||
26 | Profiles showing existing and proposed elevations along centerline of all streets. | ||
27 | Approximate stationing on all streets. | ||
28 | Location, size and invert elevations of all existing and proposed sanitary sewers and stormwater sewers and structures. | ||
29 | Preliminary drainage plan including proposed stormwater detention location. | ||
30 | Location and size of all water lines. | ||
31 | Topography at the same scale with contour interval of 1'. | ||
32 | Other specifications and references required by the local government. Construction standards and specifications, including a site grading plan for the entire subdivision. | ||
33 | Title of property, name and address of owner, and signature of surveyor. | ||
34 | Date, including revision dates. | ||
35 | Notation of approval, signature line for Planning Commission Chairman. | ||
36 | Name and address of subdivider and/or developer. | ||
DESCRIPTION | REMARKS |
37 | Copy of protective covenants, if applicable. | ||
38 | Indication of any developmental phasing or staged development timing. | ||
39 | Meets zoning requirements (i.e., minimum frontage, setbacks, area, etc). | ||
40 | Conformance with major street plan. | ||
41 | No flood hazards. | ||
42 | Right-of-way widths, meets minimum criteria. | ||
43 | Avoidance of multiple intersections. | ||
44 | Lengths of blocks, meets minimum criteria. | ||
DESCRIPTION | REMARKS | ||
1 | Received fees. | ||
2 | Ten copies of the final plat. | ||
3 | Five copies of construction drawings | ||
4 | Two copies of engineer’s estimate. | ||
5 | One copy of storm sewer calculations, storm detention calculations, and other necessary design calculations. | ||
6 | Performance surety. | ||
7 | Name of subdivision. | ||
8 | Location by section, town, range, and township. | ||
9 | Date of plat. | ||
10 | North arrow and basis of bearing. | ||
11 | Acreage to thousandths of an acre. | ||
12 | Deed book and reference page. (Plat book, if available.) | ||
13 | Name and address of the subdividers. | ||
14 | Name and address of professional engineer who prepared plans, including registration number and seal. | ||
15 | Name and address of professional surveyor who prepared plat, including registration number and seal. | ||
16 | Perimeter of subdivision to be outlined by a heavy border. | ||
17 | All dimensions. | ||
18 | Bearings and distances tot he nearest centerline of intersecting roads. | ||
DESCRIPTION | REMARKS |
19 | Names, exact location, dimensions, and right-of- way width of all streets. | ||
20 | Radii, internal angles, points of curvature, tangent bearings, chord length and bearings, lengths of arcs of all applicable streets within the plat area. | ||
21 | The exact location, dimensions, and uses of easements shall be illustrated on the plat. | ||
22 | All lots accurately dimensioned in feet and hundredths with lot numbers and acreage. | ||
23 | Replatted lots shall illustrate old lot numbers and lot lines dotted on the plat. | ||
24 | Accurate location and a description of all monuments as to type, size and whether the monument was found or set. | ||
25 | Any restrictions and covenants shall be shown on the final plat. | ||
26 | Acknowledgment dedication statement of the owner or owners to the plat. | ||
27 | A statement of intention and request for the vacation of lot lines and easements. | ||
28 | The signature of authorized representatives of local utility companies acknowledging the abandonment of easements. | ||
29 | Names of record of all abutting parcels with deed reference, acreage, and survey record reference. | ||
30 | Any section lines, corporation limits, township, and county lines. | ||
31 | Location of permanent facilities and easements for same used for drainage control such as detention basin, retention ponds, infiltration beds, etc, and statement of the provisions for the maintenance of these facilities. | ||
32 | Construction plans submitted to the OEPA for approvals as required. | ||
33 | Submitted within 12 months of preliminary approval. | ||
DESCRIPTION | REMARKS |
34 | Conforms to preliminary plat and incorporates suggested changes. | ||
35 | Street names. | ||
36 | Size of lots meet minimum requirement. | ||
37 | Setback lines meet minimum requirement. | ||
38 | Corner lot size appropriate. | ||
39 | Sufficient easements for utilities or open drainage. | ||
40 | Approval signature and date lines. | ||
41 | A notarized certification by the owner or owners. | ||
42 | Certified monument statement. | ||
DESCRIPTION | REMARKS | |
A. | PRIOR TO INSPECTION | |
Review plans, special provisions, construction & material manuals and specifications that apply to your assigned duties. | ||
Discuss your responsibility & authority with the project engineer. | ||
Discuss notification, changes, connections, delays, rejections, and tolerances. |
DESCRIPTION | REMARKS | |
B. | PRE-CONSTRUCTION CONFERENCE | |
Attendees: City Representatives, Developer/Owner, Engineer, Contractor, Superintendent, Foreman, Utility Companies | ||
Discuss phasing & schedules | ||
Discuss materials | ||
Discuss coordination | ||
Discuss safety (public & job) | ||
Discuss responsibilities | ||
C. | SANITARY SEWER & LATERALS TO R/W | |
Check pipe type & quality | ||
Trench condition | ||
Straight alignment & joints | ||
Bedding | ||
Proper initial backfill | ||
Proper backfill | ||
Prohibit groundwater from entering sanitary | ||
Wye installation & location | ||
Air test mainline & laterals | ||
Mandral test on PVC | ||
D. | SANITARY MANHOLE | |
Check type & condition | ||
Steps condition & alignment | ||
Cone type & condition | ||
Risers precast/mastic | ||
Casting - rim & lid | ||
Proper pipe connection | ||
Installation with O-rings | ||
Installation on good base | ||
Proper backfill, compacted granular under or near roadway | ||
Exfiltration test | ||
Rim & risers to proper finish grade | ||
Chimney Seal | ||
E. | WATER MAIN | |
Type & condition | ||
Valve type & condition | ||
Hydrant type & condition | ||
Trench condition | ||
Pipe alignment & joints | ||
Air release valves | ||
Isolation Valve installation & location | ||
Hydrant assemble installation & location | ||
Restrained, as needed | ||
Bedding | ||
Initial backfill, compacted granular | ||
Proper backfill, compacted granular under or near roadway | ||
Pressure test | ||
Purification test | ||
Valve & hydrant operation | ||
Laterals: Corp stop K-copper Curb stop Meter set Compacted granular backfill Proper backflow prevention Backflow prevention devices | ||
DESCRIPTION | REMARKS |
F. | STORM SEWER | |
Check pipe type, size, & quality | ||
Check catch basin & grate type, size, & quality | ||
Check manhole type, size, & quality | ||
Trench condition | ||
Straight alignment & joint sealing | ||
Bedding | ||
Proper initial backfill | ||
Proper backfill, compacted granular under or near roadway | ||
Proper connection to catch basin & manholes | ||
C.B. set in good horizontal & vertical alignment with curbs | ||
Slope & grade: Review control stakes & adjacent terrain for drainage. | ||
Field tile & other pipes reconnected & noted on plans | ||
G. | ROADWAY | |
Subgrade: | ||
All topsoil removed in roadway | ||
Compacted granular or clay fill only | ||
Proper cross slope | ||
Proper elevation | ||
Free of roots, large stones, & excess dust | ||
Proper compaction | ||
Proofroll or density test, if soft undercut and/or underdrains. | ||
Subbase: | ||
Proper material | ||
Compacted in appropriate layers | ||
Density test, if soft | ||
Protect subgrade from being rutted or damaged (back in over subbase & blade, if necessary) | ||
Proofroll subbase before prime coat | ||
Measure elevation & cross slope | ||
Surface: | ||
Appropriate moisture & temperature conditions | ||
Visual inspection of material (be aware of acceptable temperature range of mix & compensation) | ||
Proper distribution & roller | ||
Proper prime coat | ||
Lay in proper layer | ||
Watch joints & overlaps | ||
Seal against concrete curbs, etc. | ||
Measure elevation & cross slope | ||
Keep traffic off for 24 hours, if possible | ||
DESCRIPTION | REMARKS |
H. | FIXED STRUCTURES, CURBS, SIDEWALK, HEADWALL, ETC. | |
Determine proper concrete mix | ||
Appropriate moisture & temperature conditions | ||
Check all underground portions | ||
Check backfill, operation, & material | ||
Check subgrade | ||
Check subbase under curbs | ||
Review requirements for reinforcing steel | ||
Check all reinforcement | ||
Check all dowels | ||
Check for expansion joints | ||
Be aware of time concrete was batched & allowable time for placement | ||
Observe mix & placement | ||
Observe finishing procedure | ||
Needs curing material ASAP | ||
If required, check cold weather protection | ||
Needs saw joints ASAP | ||
Note when forms are removed | ||
I. | MISCELLANEOUS | |
Keep daily logs | ||
Pre-mark all existing utilities | ||
Reconnect all existing utilities | ||
Mark ends of all laterals in field-Contractor’s responsibility | ||
Mark ends of all laterals on plans | ||
Restoration | ||
Grade to drain | ||
Check trench settlement | ||
Seeding & Mulching | ||
Erosion Control | ||
Inlets | ||
Outlets | ||
Curb lines | ||
Ditches | ||
Basins | ||
Final check for debris & flow | ||
Sanitary sewer | ||
Storm sewer, manhole, & catch basin | ||
Curb lines | ||
DESCRIPTION | REMARKS | |
REQUIRED PLAN LAYOUT ORDER | ||
Title Sheet | ||
Final Plat | ||
Schematic Plan | ||
Typical Sections | ||
General Notes | ||
General Details | ||
Site Grading and Erosion Control Plan | ||
Erosion Control Details | ||
Misc. Details (e.g. pump station, intersection plan) | ||
Plan and Profile (1”=20’ horizontal, 1”=5’ vertical) | ||
Cross-Sections (1”=5’ horizontal, 1” = 5’ vertical) | ||
Detention Basin or Retention Pond Plan and Details | ||
Off-Site Utilities Plan and Profile (1”=20’ horizontal, 1” = 5’ vertical) | ||
DESCRIPTION | REMARKS | |
GENERAL |
Acceptable natural drainage and erosion control | ||
Right-of-way widths meet minimum criteria | ||
Pavement widths | ||
Radius of curvature | ||
Horizontal visibility | ||
Vertical alignment and visibility | ||
Grades | ||
Cul-de-sacs | ||
Turn around radius, right-of-way, and pavement | ||
Dead-end streets | ||
Alignment of intersection | ||
Space of intersection relative to difference in road classifications | ||
Avoidance of multiple intersection | ||
Pavement and right-of-way of intersection | ||
Streets for commercial subdivisions | ||
Repair of pavements
| ||
Streets for industrial subdivision | ||
Lengths of blocks meet minimum criteria | ||
Crosswalks | ||
Street Monuments | ||
Subgrade | ||
Base Course | ||
Surface Course | ||
Grading Plan | ||
Storm drainage system type | ||
Manholes | ||
Catch basins | ||
Headwalls | ||
Sufficient easements for utilities or open drainage | ||
Other utilities | ||
Underground utilities | ||
1. | TITLE SHEET | |
Title of Project, City, County, Township, State | ||
Index of sheets and sheet numbering | ||
Vicinity map with north arrow and project site callout | ||
City Standard Drawings reference | ||
Underground utilities note (O.U.P.S.) | ||
Signature and stamp | ||
Date of finished plans | ||
Project description | ||
Approval plan signatures | ||
Name, address, telephone number, and fax number of firm that plans are prepared by | ||
2. | FINAL PLAT | |
Copy of approved final plat | ||
See Subdivision Regulations
| ||
DESCRIPTION | REMARKS | |
3. | SCHEMATIC PLAN - LARGE SCALE LAYOUT OF THE SITE | |
At a measurable scale to show the whole site on one sheet (max. scale 1” = 100’) | ||
Show right-of-way, property lines, roadway, lot numbers, street names, and existing adjoining property lines and owners | ||
Show proposed utilities and numbering of sanitary and storm manholes and catch basins | ||
Stationing of intersections and streets | ||
Multi-baseline legend, (sheet number, stationing, description, etc.) | ||
North arrow and scale | ||
Benchmarks and locations | ||
Centerline stationing | ||
4. | TYPICAL SECTION | |
Detailed labeling | ||
Legend of pavement composition | ||
Limiting stations for each section | ||
Dimensioning, pavement, curb and gutter, curb lawn, sidewalk, right-of-way, and pavement slopes | ||
5. | GENERAL NOTES | |
All notes necessary for construction which are not defined clearly elsewhere within the plans | ||
6. | GENERAL DETAILS | |
All details necessary for construction which are not represented by City of Urbana Standard Drawings | ||
Modified City of Urbana Standard Drawings shall be redrawn for approval | ||
DESCRIPTION | REMARKS | |
7. | SITE GRADING PLAN AND EROSION CONTROL | |
A final site grading plan must be included with the construction drawings and approved by the City | ||
Proposed 1-foot contours showing all lots having proper drainage | ||
A Storm Water Pollution Prevention Plan will be required to be included with the construction drawings and approved by the City. This plan shall follow the OEPA and NPDES permit requirements and shall be submitted to and approved by OEPA prior to construction | ||
Show and label existing and proposed 1-foot contours | ||
Proposed storm manholes, catch basins, pipes, etc., labeled and numbered | ||
Concentrated flows | ||
Property lines, right-of-way, lot numbers, and owners | ||
Proposed/existing roadways | ||
Proposed diversions and erosion control (e.g. diversion ditches, fabric fence, straw bales, sediment basins.) | ||
Erosion control construction sequence list | ||
Limits of grading | ||
Proposed storm sewer pipe flows and capacities | ||
Sediment basin location | ||
North arrow and scale | ||
At a measurable scale to show the whole site on one sheet (Maximum scale 1” = 100’) | ||
8. | EROSION CONTROL DETAILS | |
Any details necessary for construction which are not represented by the City of Urbana Standard Drawings | ||
9. | MISC. DETAILS (e.g. pump station, intersection plan etc.) | |
Shall include a detail drawing with all proper labeling and dimensioning | ||
DESCRIPTION | REMARKS | |
10. | PLAN AND PROFILE | |
Use a scale of 1” = 20’ horizontal, 1”=5’ vertical | ||
Show all necessary data in sufficient detail for the complete construction of all work and improvements to be made in the plat | ||
All grade elevations shall be based on U.S.G.S. and City of Urbana datum | ||
Plan and profile sheets are required for all off- site utility extensions | ||
10A | GENERAL - PLAN | |
Show all proposed lots, streets, curbs, etc. | ||
Show all existing pavements, headwalls, piers, utilities, mailboxes, trees, etc. | ||
Typical street and curb sections | ||
Construction notes | ||
Structural details | ||
North arrow (preferably up or to the right) and scale (horizontal and vertical) | ||
Street names | ||
Centerline stations and ticks every 100 feet (south to north and west to east where possible) | ||
Easements for utilities and storm drainage | ||
Pavements and right-of-way widths | ||
Lot numbers, dimensions, and frontage | ||
Curb radius and intersections with back of curb elevations at quarter points (if not covered in separate intersection detail) | ||
Curve data: radius, delta, chord length, chord bearing, arc length, station of PC, PT, PCC, PI, PRC | ||
Sheet reference | ||
Plat section lines (boundary lines) showing stations | ||
Dimension and station utility locations | ||
Centerline bearings and/or intersecting centerline angles | ||
Final monument box call-outs set at PC, PT, PCC, PI, PRC (in pavement) intersections | ||
Drive apron stationing and width call-outs | ||
Show all existing features within 50 feet of right- of-way | ||
Proposed electric, telephone, gas, cable locations, and easements | ||
Proposed light pole layout and electric feed | ||
Match lines with stationing | ||
Intersection elevation for proper storm water drainage | ||
Benchmarks | ||
DESCRIPTION | REMARKS | |
10B | GENERAL - PROFILE | |
Existing centerline and proposed centerline profile | ||
Label proposed centerline grades (minimum grade 0.50%) | ||
Show all mainline existing utilities | ||
Existing and proposed grade elevations every 25 feet (existing elevation on bottom of sheet and proposed elevation on top of sheet. Note as to centerline or top of curb.) | ||
Show and label all vertical curves (stations, elevations, and length) | ||
10C | STORM SEWER - PLAN | |
Show and station, with offsets, the proposed storm sewers: manholes, laterals, catch basins, headwalls, etc. | ||
Label each pipe size and type | ||
Number storm manholes and catch basins. | ||
10D | STORM SEWER - PROFILE | |
Show length of span, size, grade, and class and/or type of proposed pipe | ||
Label existing pipe size and type | ||
Label existing and proposed storm water manholes, junction boxes, catch basins, etc., and show centerline of streets and stations of each | ||
Show invert elevations of all pipe at manholes, headwalls, junction boxes, catch basins, etc. | ||
Show elevation on top of manhole or catch basin | ||
Number proposed storm manholes and catch basins | ||
DESCRIPTION | REMARKS | |
10E | WATER - PLAN | |
Show and station, with offsets, the proposed waterline, laterals, deflection points, hydrants, valves, etc. | ||
Label pipe size, tees, crosses, etc. | ||
Station above items | ||
10F | WATER - PROFILE | |
Show length, size, depth, and class and/or type of pipe | ||
Show deflection points | ||
Show stations and any critical elevations for above items | ||
Label minimum coverage of water main | ||
10G | SANITARY SEWER - PLAN | |
Show sanitary sewers, manholes, laterals, cleanouts, etc. with station and offset labeled | ||
Label each pipe size | ||
Number proposed sanitary manholes and cleanouts | ||
10H | SANITARY SEWER - PROFILE | |
Show length of span, size, grade, and class and/or type of proposed pipe | ||
Show existing and proposed sanitary | ||
Show invert elevation of all pipe at manholes | ||
Show top elevations of manholes | ||
Number proposed sanitary manholes and cleanouts | ||
11. | CROSS-SECTIONS | |
Cross-sections shall be at a scale of 1”=5’ horizontal, 1”=5’ vertical | ||
Cross-sections shall be every 50 feet and at other critical areas | ||
Show all existing utilities with labels | ||
Show all proposed utilities with labels | ||
Show all proposed and existing roadway sections with existing and proposed centerline elevations | ||
Cross-section at each drive and intersection roadway | ||
12. | DETENTION BASIN OR RETENTION POND | |
Detailed site plan including inlet and outlet elevations, top of bank elevations, and emergency overflow elevations. | ||
13. | OFF-SITE | |
Refer to Page subsection (c)(10) Plan and Profile. | ||
Predominant Land Use | |
Business: | |
Downtown Area | .80 |
Neighborhood Area | .70 |
Residential: | |
Single-Family Areas | .40 |
Multi-Family Areas | .60 |
Industrial: | |
Light Areas | .70 |
Heavy Areas | .80 |
Parks, Cemeteries | .30 |
Playgrounds | .35 |
Railroad Yard Areas | .35 |
Row Crops or Open Land
| .25 |
Surface Characteristics: | |
Street: | |
Asphalt | .90 |
Concrete | .90 |
Drives and Walks | .90 |
Roofs | .85 |
Lawns | |
Flat - 2% or less | .25 |
Average - 2% to 7% | .35 |
Steep - 7% or greater
| .40 |
![]() |
Overland (Sheet) flow (Applicable as part of Tc computation only) Segment ID | |||||
1. Surface description: paved or unpaved........................ | |||||
2. Manning’s roughness coeff., n (See Figure 6.3)........ | |||||
3. Flow length, L (total L 300 ft for unpaved, L 100 ft for paved)........ ft | |||||
4. Two-yr 24-hr rainfall, P2..................................................in | 2.16 | 2.16 | |||
5. Land slope, s..................................................................ft/ft | |||||
0.007 (nL) 0.8 6. Tt = P2 0.5 S 0.4 Compute Tt ................... hr | + | = | |||
Shallow concentrated flow Segment ID | |||||
7. Surface description: paved or unpaved.......................................... | |||||
8. Flow length, L .............................................................................ft | |||||
9. Watercourse slope, s ...............................................................ft/ft | |||||
10. Average velocity, V unpaved = 16.1345(s) 0.5, or P paved = 2-.3282(s) 0.5 ..........ft/s | |||||
L 11. Tt = 3600 V Compute Tt............................hr | + | = | |||
Channel flow Segment ID | |||||
12. Cross sectional flow area, a ..................................................ft2 | |||||
13. Wetted perimeter, pw ..............................................................ft | |||||
a 14. Hydraulic radius, r = pw Compute r.......................................ft | |||||
15. Channel slope, s .....................................................................ft/ft | |||||
16. Manning’s roughness coeff., n...................................................... | |||||
1.49 r 2/3 s 1/2 17. V = n Compute V ......................ft/s | |||||
18. Flow length, L ..........................................................................ft | |||||
L 19. Tt = 3600 V Compute Tt.................................hr | + | = | |||
20. Watershed or subarea Tc or Tt (add Tt, in septs 6, 11 and 19) ......hr. | |||||
Surface Description | n1 Coeff. |
Smooth surfaces (concrete, asphalt, gravel, or bare soil) | 0.011 |
Fallow (no residue) | 0.05 |
Cultivated soils: Residue cover < = 20% Residue cover > = 20% | 0.06 0.17 |
Grass: Short grass prairie Dense grasses2 Bermuda grass | 0.15 0.24 0.41 |
Range (natural) | 0.13 |
Woods:3 Light underbrush Dense underbrush | 0.40 0.80 |
1 The n values are a composite of information compiled by Engman (1986). 2 Includes species such as weeping lovegrass, bluegrass, buffalo grass, blue grama grass, and native grass mixtures. 3 When selecting n, consider cover to a height of about 0.1 ft. This is the only part of the plant cover that will obstruct sheet flow. | |
Hours | Minutes | Return Frequency – Rainfall Intensity (in/hr) | |||||
2-yr | 5-yr | 10-yr | 25-yr | 50-yr | 100-yr | ||
.08 | 5* | 4.15 | 5.54 | 6.25 | 7.12 | 7.82 | 8.54 |
.17 | 10 | 3.35 | 4.51 | 5.08 | 5.87 | 6.20 | 6.97 |
.25 | 15 | 2.90 | 3.81 | 4.37 | 5.08 | 5.57 | 6.08 |
.33 | 20 | 2.50 | 3.29 | 3.81 | 4.46 | 4.80 | 5.36 |
.50 | 30 | 1.86 | 2.54 | 2.97 | 3.50 | 3.86 | 4.28 |
.75 | 45 | 1.40 | 1.88 | 2.20 | 2.60 | 2.88 | 3.22 |
1 | 60 | 1.12 | 1.52 | 1.78 | 2.10 | 2.34 | 2.61 |
2 | 120 | 0.68 | 0.91 | 1.08 | 1.27 | 1.42 | 1.55 |
3 | 180 | 0.50 | 0.675 | 0.80 | 0.94 | 1.05 | 1.16 |
6 | 360 | 0.30 | 0.40 | 0.48 | 0.56 | 0.62 | 0.68 |
12 | 720 | 0.16 | 0.23 | 0.27 | 0.37 | 0.36 | 0.39 |
24 | 1440 | 0.09 | 0.13 | 0.15 | 0.18 | 0.20 | 0.22 |
Q = 1.486 R 2/3 S 1/2 A n |
![]() |
CHANNEL MATERIAL | n |
Vitrified clay |
0.014 |
Cast iron pipe |
0.015 |
Smooth earth |
0.018 |
Firm gravel |
0.023 |
Corrugated metal pipe |
0.022 |
Natural channels in good condition |
0.025 |
Natural channels with stones and weeds |
0.035 |
Very poor natural channels |
0.060 |
Storm Duration td (hrs) | 30% of Impervious Area | 50% of Impervious Area | 70% of Impervious Area | 90% of Impervious Area |
0.17 | 0.28 | 0.36 | 0.44 | 0.51 |
0.33 | 0.36 | 0.45 | 0.53 | 0.61 |
0.50 | 0.42 | 0.50 | 0.59 | 0.67 |
0.67 | 0.46 | 0.54 | 0.63 | 0.71 |
0.83 | 0.49 | 0.57 | 0.66 | 0.74 |
1.0 | 0.51 | 0.59 | 0.68 | 0.77 |
1.5 | 0.56 | 0.65 | 0.73 | 0.82 |
2.0 | 0.59 | 0.69 | 0.76 | 0.84 |
3.0 | 0.64 | 0.72 | 0.79 | 0.86 |
Storm Duration td (hrs) | Runoff Coefficient C ____% Impervious | Rainfall Intensity i (inches/hr) | Post Inflow Rate (100 year) I(td) (CiA) (cfs) | Pre Allowable Outflow Rate (5 year) O (.2)(3.65)(A) (cfs) | Storage Rate I(td)-O (cfs) | Required Storage [I(td)-O]td/12 (acre-ft) |
0.17 | 6.97 | |||||
0.33 | 5.36 | |||||
0.50 | 4.28 | |||||
0.67 | 3.58 | |||||
0.83 | 3.05 | |||||
1.0 | 2.61 | |||||
1.5 | 2.01 | |||||
2.0 | 1.55 | |||||
3.0 | 1.16 | |||||
![]() |
No. of Families | Service Size (inches) | Meter Size (inches) |
1 | 3/4 | 5/8 x 3/4 |
2-5 | 1 | 1 |
6-8 | 1-1/2 | 1 1/2 |
9-12 | 2 | 1 1/2 |
13-20 | 2 | 2 |
21-50 | 4 | 3 |
51-115 | 4 | 4 |
Pipe diameter (inches) |
6 |
8 |
10 |
12 |
Tap sizes (inches) |
1 |
1-1/4 |
1-1/2 |
2 |
Maximum Flow Demand (GPM) | Meter Size (inches) |
20 |
5/8 x 3/4 |
30 |
3/4 |
50 |
1 |
100 |
1 1/2 |
160 |
2 |
320 |
3 |
500 |
4 |
1000 |
6 |
Q= 1.486 R2/3 S1/2 A n |
WASTEWATER SOURCE | GALLONS PER DAY | LITERS PER DAY |
Airports | ||
Per Employee | 20 | 76 |
Per Passenger | 5 | 19 |
Apartments | ||
One Bedroom | 250 | 947 |
Two Bedrooms | 300 | 1,137 |
Three Bedrooms | 350 | 1,326 |
Assembly Halls | ||
Per Seat | 2 | 8 |
Bowling Alleys (no food service) | ||
Per Lane | 75 | 284 |
Camps | ||
Individual bath units - per units | 50 | 189 |
Central Bathhouse - per person | 35 | 133 |
Car Wash (per car, no recycling) | 80 | 304 |
Churches | ||
Small - per sanctuary seat | 3-5 | 11-19 |
Large with kitchen - per sanctuary seat | 5-7 | 19-27 |
Country Clubs (including food service) | ||
Per Member | 50 | 189 |
Dance Halls | ||
Per person | 2 | 9 |
Factories | ||
No showers - per employee | 25 | 95 |
With showers - per employee | 35 | 133 |
Family Dwellings | ||
Per person | 100 | 379 |
*Food Service Operations | ||
Ordinary Restaurant (not 24 hour) per seat | 35 | 133 |
24-hour Restaurant | 50 | 189 |
* The listed estimated sewage flows are to be used for the design of sewers and should not be used for the design of treatment units. | ||
Banquet rooms - per seat | 5 | 19 |
Restaurant along freeway - per seat | 100 | 379 |
Tavern (very little food servie) per seat | 35 | 133 |
Curb Service (drive in) - per car space | 50 | 189 |
Vending Machine Restaurants - per seat | 35 | 133 |
Highway Rest Areas | ||
Per Car | 1-9 | 4-34 |
Hospitals | ||
No resident personnel - per bed | 300 | 1,137 |
Institutions | ||
Residents - per bed | 100 | 379 |
Laundries | ||
Coin operated - per machine (standard size machine) | 400 | 1,137 |
Motels | ||
Per Unit | 100 | 379 |
Nursing and Rest Homes | ||
Per patient | 150 | 568 |
Per resident employee | 100 | 379 |
Office Buildings | ||
(exclusie of cafeteria or kitchen) Per employee per shift | 20 | 76 |
Parks | ||
With toilet facility per person | 5 | 19 |
With showers, bathhouse, toilets, - per person | 10 | 38 |
WASTEWATER SOURCE | GALLONS PER DAY | LITERS PER DAY |
Schools | ||
Elementary (not including showers or cafeteria) per pupil | 1- | 38 |
High and Junior High (not including showers or cafeteria) per pupil | 15 | 57 |
Add for cafeteria - per pupil | 5 | 19 |
Add for showers - per pupil | 5 | 19 |
Service Stations | ||
First bay | 1,000 | 3,789 |
Each additional bay | 500 | 1,895 |
Shopping Centers | ||
(without food service or laundries) per acre of floor space | 0.2 per sq. ft. | 8 per sq. meter |
Stores | ||
Per toilet per shift | 400 | 1,516 |
Swimming Pool | ||
(average with hot water shower) per swimmer (design load) | 3-5 | 11-19 |
Theaters | ||
Drive-in Movies - per car space | 5 | 19 |
Movie - per seat | 5 | 19 |
Trailer Parks | ||
Per Trailer space | 300 | 1,137 |
Travel Trailer Dumping Stations | ||
At service station | Consult District Office of OEPA | |
Travel Trailer Parks and Camps | ||
- Per trailer or tent space | 125 | 474 |
Vacation Cottage | ||
- Per peson | 50 | 189 |
Youth and Recreation Camps | ||
- Per person | 50 | 189 |
Sewer Size | Minimum Slope in Feet Per 100 Feet |
8 | 0.40 |
10 | 0.28 |
12 | 0.22 |
15 | 0.15 |
18 | 0.12 |
21 | 0.10 |
24 | 0.08 |
27 | 0.067 |
30 | 0.058 |
36 | 0.046 |
![]() |
26,500 = 200 130 |
Group | Percent of Slope | Front Yard (ft.) | Side Yard in Percentage of lot width | Right of Way (ft.) | Pavement (ft.) |
1 | 15 + 25 | 25 | 10 | 50 | 24 |
2 | 26-30 | 23 | 10 | 50 | 24 |
3 | 31-Over | 20 | 10 | 50 | 24 |
Subdivision Regulations
DESCRIPTION | REMARKS | ||
1 | Received fees. | ||
2 | Ten copies of plat (at a scale of not more than 1" = 100'). | ||
3 | Name of Subdivision. | ||
4 | Location of property with respect to surrounding property and streets. | ||
5 | Location by township, section, town and range. | ||
6 | Names of all adjoining property owners, or names of adjoining developers. | ||
7 | Name of adjoining subdivisions. | ||
8 | Location and names of adjoining streets. | ||
9 | Location of corporation line, if applicable. | ||
10 | Location and dimensions of all boundary lines of the property in feet and decimals of a foot. | ||
11 | Vicinity sketch. | ||
12 | Indication of zoning. | ||
13 | Location of existing easements. | ||
14 | Location of existing water bodies, streams, and other pertinent features such as railroads, buildings, parks, cemeteries, drainage ditches, bridges, etc. | ||
15 | Locations, dimensions and areas of all proposed or existing lots. | ||
16 | Location and dimensions of all property proposed to be set aside for park or playground use, or other public or private reservation, with designation of the purpose thereof, and conditions, if any, of the dedication or reservation. | ||
DESCRIPTION | REMARKS |
17 | Date of plat. | ||
18 | Scale of plat. | ||
19 | North arrow. | ||
20 | Data from which the location, bearing and length of all lines can be determined and reproduced on the ground. | ||
21 | Names of new streets as approved by the Planning Commission. | ||
22 | Indication of the use of any lot and all uses other than residential. | ||
23 | Lots consecutively numbered. | ||
24 | Approximate dimensions of lots, including lot area. | ||
25 | Front building setback lines. | ||
26 | Profiles showing existing and proposed elevations along centerline of all streets. | ||
27 | Approximate stationing on all streets. | ||
28 | Location, size and invert elevations of all existing and proposed sanitary sewers and stormwater sewers and structures. | ||
29 | Preliminary drainage plan including proposed stormwater detention location. | ||
30 | Location and size of all water lines. | ||
31 | Topography at the same scale with contour interval of 1'. | ||
32 | Other specifications and references required by the local government. Construction standards and specifications, including a site grading plan for the entire subdivision. | ||
33 | Title of property, name and address of owner, and signature of surveyor. | ||
34 | Date, including revision dates. | ||
35 | Notation of approval, signature line for Planning Commission Chairman. | ||
36 | Name and address of subdivider and/or developer. | ||
DESCRIPTION | REMARKS |
37 | Copy of protective covenants, if applicable. | ||
38 | Indication of any developmental phasing or staged development timing. | ||
39 | Meets zoning requirements (i.e., minimum frontage, setbacks, area, etc). | ||
40 | Conformance with major street plan. | ||
41 | No flood hazards. | ||
42 | Right-of-way widths, meets minimum criteria. | ||
43 | Avoidance of multiple intersections. | ||
44 | Lengths of blocks, meets minimum criteria. | ||
DESCRIPTION | REMARKS | ||
1 | Received fees. | ||
2 | Ten copies of the final plat. | ||
3 | Five copies of construction drawings | ||
4 | Two copies of engineer’s estimate. | ||
5 | One copy of storm sewer calculations, storm detention calculations, and other necessary design calculations. | ||
6 | Performance surety. | ||
7 | Name of subdivision. | ||
8 | Location by section, town, range, and township. | ||
9 | Date of plat. | ||
10 | North arrow and basis of bearing. | ||
11 | Acreage to thousandths of an acre. | ||
12 | Deed book and reference page. (Plat book, if available.) | ||
13 | Name and address of the subdividers. | ||
14 | Name and address of professional engineer who prepared plans, including registration number and seal. | ||
15 | Name and address of professional surveyor who prepared plat, including registration number and seal. | ||
16 | Perimeter of subdivision to be outlined by a heavy border. | ||
17 | All dimensions. | ||
18 | Bearings and distances tot he nearest centerline of intersecting roads. | ||
DESCRIPTION | REMARKS |
19 | Names, exact location, dimensions, and right-of- way width of all streets. | ||
20 | Radii, internal angles, points of curvature, tangent bearings, chord length and bearings, lengths of arcs of all applicable streets within the plat area. | ||
21 | The exact location, dimensions, and uses of easements shall be illustrated on the plat. | ||
22 | All lots accurately dimensioned in feet and hundredths with lot numbers and acreage. | ||
23 | Replatted lots shall illustrate old lot numbers and lot lines dotted on the plat. | ||
24 | Accurate location and a description of all monuments as to type, size and whether the monument was found or set. | ||
25 | Any restrictions and covenants shall be shown on the final plat. | ||
26 | Acknowledgment dedication statement of the owner or owners to the plat. | ||
27 | A statement of intention and request for the vacation of lot lines and easements. | ||
28 | The signature of authorized representatives of local utility companies acknowledging the abandonment of easements. | ||
29 | Names of record of all abutting parcels with deed reference, acreage, and survey record reference. | ||
30 | Any section lines, corporation limits, township, and county lines. | ||
31 | Location of permanent facilities and easements for same used for drainage control such as detention basin, retention ponds, infiltration beds, etc, and statement of the provisions for the maintenance of these facilities. | ||
32 | Construction plans submitted to the OEPA for approvals as required. | ||
33 | Submitted within 12 months of preliminary approval. | ||
DESCRIPTION | REMARKS |
34 | Conforms to preliminary plat and incorporates suggested changes. | ||
35 | Street names. | ||
36 | Size of lots meet minimum requirement. | ||
37 | Setback lines meet minimum requirement. | ||
38 | Corner lot size appropriate. | ||
39 | Sufficient easements for utilities or open drainage. | ||
40 | Approval signature and date lines. | ||
41 | A notarized certification by the owner or owners. | ||
42 | Certified monument statement. | ||
DESCRIPTION | REMARKS | |
A. | PRIOR TO INSPECTION | |
Review plans, special provisions, construction & material manuals and specifications that apply to your assigned duties. | ||
Discuss your responsibility & authority with the project engineer. | ||
Discuss notification, changes, connections, delays, rejections, and tolerances. |
DESCRIPTION | REMARKS | |
B. | PRE-CONSTRUCTION CONFERENCE | |
Attendees: City Representatives, Developer/Owner, Engineer, Contractor, Superintendent, Foreman, Utility Companies | ||
Discuss phasing & schedules | ||
Discuss materials | ||
Discuss coordination | ||
Discuss safety (public & job) | ||
Discuss responsibilities | ||
C. | SANITARY SEWER & LATERALS TO R/W | |
Check pipe type & quality | ||
Trench condition | ||
Straight alignment & joints | ||
Bedding | ||
Proper initial backfill | ||
Proper backfill | ||
Prohibit groundwater from entering sanitary | ||
Wye installation & location | ||
Air test mainline & laterals | ||
Mandral test on PVC | ||
D. | SANITARY MANHOLE | |
Check type & condition | ||
Steps condition & alignment | ||
Cone type & condition | ||
Risers precast/mastic | ||
Casting - rim & lid | ||
Proper pipe connection | ||
Installation with O-rings | ||
Installation on good base | ||
Proper backfill, compacted granular under or near roadway | ||
Exfiltration test | ||
Rim & risers to proper finish grade | ||
Chimney Seal | ||
E. | WATER MAIN | |
Type & condition | ||
Valve type & condition | ||
Hydrant type & condition | ||
Trench condition | ||
Pipe alignment & joints | ||
Air release valves | ||
Isolation Valve installation & location | ||
Hydrant assemble installation & location | ||
Restrained, as needed | ||
Bedding | ||
Initial backfill, compacted granular | ||
Proper backfill, compacted granular under or near roadway | ||
Pressure test | ||
Purification test | ||
Valve & hydrant operation | ||
Laterals: Corp stop K-copper Curb stop Meter set Compacted granular backfill Proper backflow prevention Backflow prevention devices | ||
DESCRIPTION | REMARKS |
F. | STORM SEWER | |
Check pipe type, size, & quality | ||
Check catch basin & grate type, size, & quality | ||
Check manhole type, size, & quality | ||
Trench condition | ||
Straight alignment & joint sealing | ||
Bedding | ||
Proper initial backfill | ||
Proper backfill, compacted granular under or near roadway | ||
Proper connection to catch basin & manholes | ||
C.B. set in good horizontal & vertical alignment with curbs | ||
Slope & grade: Review control stakes & adjacent terrain for drainage. | ||
Field tile & other pipes reconnected & noted on plans | ||
G. | ROADWAY | |
Subgrade: | ||
All topsoil removed in roadway | ||
Compacted granular or clay fill only | ||
Proper cross slope | ||
Proper elevation | ||
Free of roots, large stones, & excess dust | ||
Proper compaction | ||
Proofroll or density test, if soft undercut and/or underdrains. | ||
Subbase: | ||
Proper material | ||
Compacted in appropriate layers | ||
Density test, if soft | ||
Protect subgrade from being rutted or damaged (back in over subbase & blade, if necessary) | ||
Proofroll subbase before prime coat | ||
Measure elevation & cross slope | ||
Surface: | ||
Appropriate moisture & temperature conditions | ||
Visual inspection of material (be aware of acceptable temperature range of mix & compensation) | ||
Proper distribution & roller | ||
Proper prime coat | ||
Lay in proper layer | ||
Watch joints & overlaps | ||
Seal against concrete curbs, etc. | ||
Measure elevation & cross slope | ||
Keep traffic off for 24 hours, if possible | ||
DESCRIPTION | REMARKS |
H. | FIXED STRUCTURES, CURBS, SIDEWALK, HEADWALL, ETC. | |
Determine proper concrete mix | ||
Appropriate moisture & temperature conditions | ||
Check all underground portions | ||
Check backfill, operation, & material | ||
Check subgrade | ||
Check subbase under curbs | ||
Review requirements for reinforcing steel | ||
Check all reinforcement | ||
Check all dowels | ||
Check for expansion joints | ||
Be aware of time concrete was batched & allowable time for placement | ||
Observe mix & placement | ||
Observe finishing procedure | ||
Needs curing material ASAP | ||
If required, check cold weather protection | ||
Needs saw joints ASAP | ||
Note when forms are removed | ||
I. | MISCELLANEOUS | |
Keep daily logs | ||
Pre-mark all existing utilities | ||
Reconnect all existing utilities | ||
Mark ends of all laterals in field-Contractor’s responsibility | ||
Mark ends of all laterals on plans | ||
Restoration | ||
Grade to drain | ||
Check trench settlement | ||
Seeding & Mulching | ||
Erosion Control | ||
Inlets | ||
Outlets | ||
Curb lines | ||
Ditches | ||
Basins | ||
Final check for debris & flow | ||
Sanitary sewer | ||
Storm sewer, manhole, & catch basin | ||
Curb lines | ||
DESCRIPTION | REMARKS | |
REQUIRED PLAN LAYOUT ORDER | ||
Title Sheet | ||
Final Plat | ||
Schematic Plan | ||
Typical Sections | ||
General Notes | ||
General Details | ||
Site Grading and Erosion Control Plan | ||
Erosion Control Details | ||
Misc. Details (e.g. pump station, intersection plan) | ||
Plan and Profile (1”=20’ horizontal, 1”=5’ vertical) | ||
Cross-Sections (1”=5’ horizontal, 1” = 5’ vertical) | ||
Detention Basin or Retention Pond Plan and Details | ||
Off-Site Utilities Plan and Profile (1”=20’ horizontal, 1” = 5’ vertical) | ||
DESCRIPTION | REMARKS | |
GENERAL |
Acceptable natural drainage and erosion control | ||
Right-of-way widths meet minimum criteria | ||
Pavement widths | ||
Radius of curvature | ||
Horizontal visibility | ||
Vertical alignment and visibility | ||
Grades | ||
Cul-de-sacs | ||
Turn around radius, right-of-way, and pavement | ||
Dead-end streets | ||
Alignment of intersection | ||
Space of intersection relative to difference in road classifications | ||
Avoidance of multiple intersection | ||
Pavement and right-of-way of intersection | ||
Streets for commercial subdivisions | ||
Repair of pavements
| ||
Streets for industrial subdivision | ||
Lengths of blocks meet minimum criteria | ||
Crosswalks | ||
Street Monuments | ||
Subgrade | ||
Base Course | ||
Surface Course | ||
Grading Plan | ||
Storm drainage system type | ||
Manholes | ||
Catch basins | ||
Headwalls | ||
Sufficient easements for utilities or open drainage | ||
Other utilities | ||
Underground utilities | ||
1. | TITLE SHEET | |
Title of Project, City, County, Township, State | ||
Index of sheets and sheet numbering | ||
Vicinity map with north arrow and project site callout | ||
City Standard Drawings reference | ||
Underground utilities note (O.U.P.S.) | ||
Signature and stamp | ||
Date of finished plans | ||
Project description | ||
Approval plan signatures | ||
Name, address, telephone number, and fax number of firm that plans are prepared by | ||
2. | FINAL PLAT | |
Copy of approved final plat | ||
See Subdivision Regulations
| ||
DESCRIPTION | REMARKS | |
3. | SCHEMATIC PLAN - LARGE SCALE LAYOUT OF THE SITE | |
At a measurable scale to show the whole site on one sheet (max. scale 1” = 100’) | ||
Show right-of-way, property lines, roadway, lot numbers, street names, and existing adjoining property lines and owners | ||
Show proposed utilities and numbering of sanitary and storm manholes and catch basins | ||
Stationing of intersections and streets | ||
Multi-baseline legend, (sheet number, stationing, description, etc.) | ||
North arrow and scale | ||
Benchmarks and locations | ||
Centerline stationing | ||
4. | TYPICAL SECTION | |
Detailed labeling | ||
Legend of pavement composition | ||
Limiting stations for each section | ||
Dimensioning, pavement, curb and gutter, curb lawn, sidewalk, right-of-way, and pavement slopes | ||
5. | GENERAL NOTES | |
All notes necessary for construction which are not defined clearly elsewhere within the plans | ||
6. | GENERAL DETAILS | |
All details necessary for construction which are not represented by City of Urbana Standard Drawings | ||
Modified City of Urbana Standard Drawings shall be redrawn for approval | ||
DESCRIPTION | REMARKS | |
7. | SITE GRADING PLAN AND EROSION CONTROL | |
A final site grading plan must be included with the construction drawings and approved by the City | ||
Proposed 1-foot contours showing all lots having proper drainage | ||
A Storm Water Pollution Prevention Plan will be required to be included with the construction drawings and approved by the City. This plan shall follow the OEPA and NPDES permit requirements and shall be submitted to and approved by OEPA prior to construction | ||
Show and label existing and proposed 1-foot contours | ||
Proposed storm manholes, catch basins, pipes, etc., labeled and numbered | ||
Concentrated flows | ||
Property lines, right-of-way, lot numbers, and owners | ||
Proposed/existing roadways | ||
Proposed diversions and erosion control (e.g. diversion ditches, fabric fence, straw bales, sediment basins.) | ||
Erosion control construction sequence list | ||
Limits of grading | ||
Proposed storm sewer pipe flows and capacities | ||
Sediment basin location | ||
North arrow and scale | ||
At a measurable scale to show the whole site on one sheet (Maximum scale 1” = 100’) | ||
8. | EROSION CONTROL DETAILS | |
Any details necessary for construction which are not represented by the City of Urbana Standard Drawings | ||
9. | MISC. DETAILS (e.g. pump station, intersection plan etc.) | |
Shall include a detail drawing with all proper labeling and dimensioning | ||
DESCRIPTION | REMARKS | |
10. | PLAN AND PROFILE | |
Use a scale of 1” = 20’ horizontal, 1”=5’ vertical | ||
Show all necessary data in sufficient detail for the complete construction of all work and improvements to be made in the plat | ||
All grade elevations shall be based on U.S.G.S. and City of Urbana datum | ||
Plan and profile sheets are required for all off- site utility extensions | ||
10A | GENERAL - PLAN | |
Show all proposed lots, streets, curbs, etc. | ||
Show all existing pavements, headwalls, piers, utilities, mailboxes, trees, etc. | ||
Typical street and curb sections | ||
Construction notes | ||
Structural details | ||
North arrow (preferably up or to the right) and scale (horizontal and vertical) | ||
Street names | ||
Centerline stations and ticks every 100 feet (south to north and west to east where possible) | ||
Easements for utilities and storm drainage | ||
Pavements and right-of-way widths | ||
Lot numbers, dimensions, and frontage | ||
Curb radius and intersections with back of curb elevations at quarter points (if not covered in separate intersection detail) | ||
Curve data: radius, delta, chord length, chord bearing, arc length, station of PC, PT, PCC, PI, PRC | ||
Sheet reference | ||
Plat section lines (boundary lines) showing stations | ||
Dimension and station utility locations | ||
Centerline bearings and/or intersecting centerline angles | ||
Final monument box call-outs set at PC, PT, PCC, PI, PRC (in pavement) intersections | ||
Drive apron stationing and width call-outs | ||
Show all existing features within 50 feet of right- of-way | ||
Proposed electric, telephone, gas, cable locations, and easements | ||
Proposed light pole layout and electric feed | ||
Match lines with stationing | ||
Intersection elevation for proper storm water drainage | ||
Benchmarks | ||
DESCRIPTION | REMARKS | |
10B | GENERAL - PROFILE | |
Existing centerline and proposed centerline profile | ||
Label proposed centerline grades (minimum grade 0.50%) | ||
Show all mainline existing utilities | ||
Existing and proposed grade elevations every 25 feet (existing elevation on bottom of sheet and proposed elevation on top of sheet. Note as to centerline or top of curb.) | ||
Show and label all vertical curves (stations, elevations, and length) | ||
10C | STORM SEWER - PLAN | |
Show and station, with offsets, the proposed storm sewers: manholes, laterals, catch basins, headwalls, etc. | ||
Label each pipe size and type | ||
Number storm manholes and catch basins. | ||
10D | STORM SEWER - PROFILE | |
Show length of span, size, grade, and class and/or type of proposed pipe | ||
Label existing pipe size and type | ||
Label existing and proposed storm water manholes, junction boxes, catch basins, etc., and show centerline of streets and stations of each | ||
Show invert elevations of all pipe at manholes, headwalls, junction boxes, catch basins, etc. | ||
Show elevation on top of manhole or catch basin | ||
Number proposed storm manholes and catch basins | ||
DESCRIPTION | REMARKS | |
10E | WATER - PLAN | |
Show and station, with offsets, the proposed waterline, laterals, deflection points, hydrants, valves, etc. | ||
Label pipe size, tees, crosses, etc. | ||
Station above items | ||
10F | WATER - PROFILE | |
Show length, size, depth, and class and/or type of pipe | ||
Show deflection points | ||
Show stations and any critical elevations for above items | ||
Label minimum coverage of water main | ||
10G | SANITARY SEWER - PLAN | |
Show sanitary sewers, manholes, laterals, cleanouts, etc. with station and offset labeled | ||
Label each pipe size | ||
Number proposed sanitary manholes and cleanouts | ||
10H | SANITARY SEWER - PROFILE | |
Show length of span, size, grade, and class and/or type of proposed pipe | ||
Show existing and proposed sanitary | ||
Show invert elevation of all pipe at manholes | ||
Show top elevations of manholes | ||
Number proposed sanitary manholes and cleanouts | ||
11. | CROSS-SECTIONS | |
Cross-sections shall be at a scale of 1”=5’ horizontal, 1”=5’ vertical | ||
Cross-sections shall be every 50 feet and at other critical areas | ||
Show all existing utilities with labels | ||
Show all proposed utilities with labels | ||
Show all proposed and existing roadway sections with existing and proposed centerline elevations | ||
Cross-section at each drive and intersection roadway | ||
12. | DETENTION BASIN OR RETENTION POND | |
Detailed site plan including inlet and outlet elevations, top of bank elevations, and emergency overflow elevations. | ||
13. | OFF-SITE | |
Refer to Page subsection (c)(10) Plan and Profile. | ||
Predominant Land Use | |
Business: | |
Downtown Area | .80 |
Neighborhood Area | .70 |
Residential: | |
Single-Family Areas | .40 |
Multi-Family Areas | .60 |
Industrial: | |
Light Areas | .70 |
Heavy Areas | .80 |
Parks, Cemeteries | .30 |
Playgrounds | .35 |
Railroad Yard Areas | .35 |
Row Crops or Open Land
| .25 |
Surface Characteristics: | |
Street: | |
Asphalt | .90 |
Concrete | .90 |
Drives and Walks | .90 |
Roofs | .85 |
Lawns | |
Flat - 2% or less | .25 |
Average - 2% to 7% | .35 |
Steep - 7% or greater
| .40 |
![]() |
Overland (Sheet) flow (Applicable as part of Tc computation only) Segment ID | |||||
1. Surface description: paved or unpaved........................ | |||||
2. Manning’s roughness coeff., n (See Figure 6.3)........ | |||||
3. Flow length, L (total L 300 ft for unpaved, L 100 ft for paved)........ ft | |||||
4. Two-yr 24-hr rainfall, P2..................................................in | 2.16 | 2.16 | |||
5. Land slope, s..................................................................ft/ft | |||||
0.007 (nL) 0.8 6. Tt = P2 0.5 S 0.4 Compute Tt ................... hr | + | = | |||
Shallow concentrated flow Segment ID | |||||
7. Surface description: paved or unpaved.......................................... | |||||
8. Flow length, L .............................................................................ft | |||||
9. Watercourse slope, s ...............................................................ft/ft | |||||
10. Average velocity, V unpaved = 16.1345(s) 0.5, or P paved = 2-.3282(s) 0.5 ..........ft/s | |||||
L 11. Tt = 3600 V Compute Tt............................hr | + | = | |||
Channel flow Segment ID | |||||
12. Cross sectional flow area, a ..................................................ft2 | |||||
13. Wetted perimeter, pw ..............................................................ft | |||||
a 14. Hydraulic radius, r = pw Compute r.......................................ft | |||||
15. Channel slope, s .....................................................................ft/ft | |||||
16. Manning’s roughness coeff., n...................................................... | |||||
1.49 r 2/3 s 1/2 17. V = n Compute V ......................ft/s | |||||
18. Flow length, L ..........................................................................ft | |||||
L 19. Tt = 3600 V Compute Tt.................................hr | + | = | |||
20. Watershed or subarea Tc or Tt (add Tt, in septs 6, 11 and 19) ......hr. | |||||
Surface Description | n1 Coeff. |
Smooth surfaces (concrete, asphalt, gravel, or bare soil) | 0.011 |
Fallow (no residue) | 0.05 |
Cultivated soils: Residue cover < = 20% Residue cover > = 20% | 0.06 0.17 |
Grass: Short grass prairie Dense grasses2 Bermuda grass | 0.15 0.24 0.41 |
Range (natural) | 0.13 |
Woods:3 Light underbrush Dense underbrush | 0.40 0.80 |
1 The n values are a composite of information compiled by Engman (1986). 2 Includes species such as weeping lovegrass, bluegrass, buffalo grass, blue grama grass, and native grass mixtures. 3 When selecting n, consider cover to a height of about 0.1 ft. This is the only part of the plant cover that will obstruct sheet flow. | |
Hours | Minutes | Return Frequency – Rainfall Intensity (in/hr) | |||||
2-yr | 5-yr | 10-yr | 25-yr | 50-yr | 100-yr | ||
.08 | 5* | 4.15 | 5.54 | 6.25 | 7.12 | 7.82 | 8.54 |
.17 | 10 | 3.35 | 4.51 | 5.08 | 5.87 | 6.20 | 6.97 |
.25 | 15 | 2.90 | 3.81 | 4.37 | 5.08 | 5.57 | 6.08 |
.33 | 20 | 2.50 | 3.29 | 3.81 | 4.46 | 4.80 | 5.36 |
.50 | 30 | 1.86 | 2.54 | 2.97 | 3.50 | 3.86 | 4.28 |
.75 | 45 | 1.40 | 1.88 | 2.20 | 2.60 | 2.88 | 3.22 |
1 | 60 | 1.12 | 1.52 | 1.78 | 2.10 | 2.34 | 2.61 |
2 | 120 | 0.68 | 0.91 | 1.08 | 1.27 | 1.42 | 1.55 |
3 | 180 | 0.50 | 0.675 | 0.80 | 0.94 | 1.05 | 1.16 |
6 | 360 | 0.30 | 0.40 | 0.48 | 0.56 | 0.62 | 0.68 |
12 | 720 | 0.16 | 0.23 | 0.27 | 0.37 | 0.36 | 0.39 |
24 | 1440 | 0.09 | 0.13 | 0.15 | 0.18 | 0.20 | 0.22 |
Q = 1.486 R 2/3 S 1/2 A n |
![]() |
CHANNEL MATERIAL | n |
Vitrified clay |
0.014 |
Cast iron pipe |
0.015 |
Smooth earth |
0.018 |
Firm gravel |
0.023 |
Corrugated metal pipe |
0.022 |
Natural channels in good condition |
0.025 |
Natural channels with stones and weeds |
0.035 |
Very poor natural channels |
0.060 |
Storm Duration td (hrs) | 30% of Impervious Area | 50% of Impervious Area | 70% of Impervious Area | 90% of Impervious Area |
0.17 | 0.28 | 0.36 | 0.44 | 0.51 |
0.33 | 0.36 | 0.45 | 0.53 | 0.61 |
0.50 | 0.42 | 0.50 | 0.59 | 0.67 |
0.67 | 0.46 | 0.54 | 0.63 | 0.71 |
0.83 | 0.49 | 0.57 | 0.66 | 0.74 |
1.0 | 0.51 | 0.59 | 0.68 | 0.77 |
1.5 | 0.56 | 0.65 | 0.73 | 0.82 |
2.0 | 0.59 | 0.69 | 0.76 | 0.84 |
3.0 | 0.64 | 0.72 | 0.79 | 0.86 |
Storm Duration td (hrs) | Runoff Coefficient C ____% Impervious | Rainfall Intensity i (inches/hr) | Post Inflow Rate (100 year) I(td) (CiA) (cfs) | Pre Allowable Outflow Rate (5 year) O (.2)(3.65)(A) (cfs) | Storage Rate I(td)-O (cfs) | Required Storage [I(td)-O]td/12 (acre-ft) |
0.17 | 6.97 | |||||
0.33 | 5.36 | |||||
0.50 | 4.28 | |||||
0.67 | 3.58 | |||||
0.83 | 3.05 | |||||
1.0 | 2.61 | |||||
1.5 | 2.01 | |||||
2.0 | 1.55 | |||||
3.0 | 1.16 | |||||
![]() |
No. of Families | Service Size (inches) | Meter Size (inches) |
1 | 3/4 | 5/8 x 3/4 |
2-5 | 1 | 1 |
6-8 | 1-1/2 | 1 1/2 |
9-12 | 2 | 1 1/2 |
13-20 | 2 | 2 |
21-50 | 4 | 3 |
51-115 | 4 | 4 |
Pipe diameter (inches) |
6 |
8 |
10 |
12 |
Tap sizes (inches) |
1 |
1-1/4 |
1-1/2 |
2 |
Maximum Flow Demand (GPM) | Meter Size (inches) |
20 |
5/8 x 3/4 |
30 |
3/4 |
50 |
1 |
100 |
1 1/2 |
160 |
2 |
320 |
3 |
500 |
4 |
1000 |
6 |
Q= 1.486 R2/3 S1/2 A n |
WASTEWATER SOURCE | GALLONS PER DAY | LITERS PER DAY |
Airports | ||
Per Employee | 20 | 76 |
Per Passenger | 5 | 19 |
Apartments | ||
One Bedroom | 250 | 947 |
Two Bedrooms | 300 | 1,137 |
Three Bedrooms | 350 | 1,326 |
Assembly Halls | ||
Per Seat | 2 | 8 |
Bowling Alleys (no food service) | ||
Per Lane | 75 | 284 |
Camps | ||
Individual bath units - per units | 50 | 189 |
Central Bathhouse - per person | 35 | 133 |
Car Wash (per car, no recycling) | 80 | 304 |
Churches | ||
Small - per sanctuary seat | 3-5 | 11-19 |
Large with kitchen - per sanctuary seat | 5-7 | 19-27 |
Country Clubs (including food service) | ||
Per Member | 50 | 189 |
Dance Halls | ||
Per person | 2 | 9 |
Factories | ||
No showers - per employee | 25 | 95 |
With showers - per employee | 35 | 133 |
Family Dwellings | ||
Per person | 100 | 379 |
*Food Service Operations | ||
Ordinary Restaurant (not 24 hour) per seat | 35 | 133 |
24-hour Restaurant | 50 | 189 |
* The listed estimated sewage flows are to be used for the design of sewers and should not be used for the design of treatment units. | ||
Banquet rooms - per seat | 5 | 19 |
Restaurant along freeway - per seat | 100 | 379 |
Tavern (very little food servie) per seat | 35 | 133 |
Curb Service (drive in) - per car space | 50 | 189 |
Vending Machine Restaurants - per seat | 35 | 133 |
Highway Rest Areas | ||
Per Car | 1-9 | 4-34 |
Hospitals | ||
No resident personnel - per bed | 300 | 1,137 |
Institutions | ||
Residents - per bed | 100 | 379 |
Laundries | ||
Coin operated - per machine (standard size machine) | 400 | 1,137 |
Motels | ||
Per Unit | 100 | 379 |
Nursing and Rest Homes | ||
Per patient | 150 | 568 |
Per resident employee | 100 | 379 |
Office Buildings | ||
(exclusie of cafeteria or kitchen) Per employee per shift | 20 | 76 |
Parks | ||
With toilet facility per person | 5 | 19 |
With showers, bathhouse, toilets, - per person | 10 | 38 |
WASTEWATER SOURCE | GALLONS PER DAY | LITERS PER DAY |
Schools | ||
Elementary (not including showers or cafeteria) per pupil | 1- | 38 |
High and Junior High (not including showers or cafeteria) per pupil | 15 | 57 |
Add for cafeteria - per pupil | 5 | 19 |
Add for showers - per pupil | 5 | 19 |
Service Stations | ||
First bay | 1,000 | 3,789 |
Each additional bay | 500 | 1,895 |
Shopping Centers | ||
(without food service or laundries) per acre of floor space | 0.2 per sq. ft. | 8 per sq. meter |
Stores | ||
Per toilet per shift | 400 | 1,516 |
Swimming Pool | ||
(average with hot water shower) per swimmer (design load) | 3-5 | 11-19 |
Theaters | ||
Drive-in Movies - per car space | 5 | 19 |
Movie - per seat | 5 | 19 |
Trailer Parks | ||
Per Trailer space | 300 | 1,137 |
Travel Trailer Dumping Stations | ||
At service station | Consult District Office of OEPA | |
Travel Trailer Parks and Camps | ||
- Per trailer or tent space | 125 | 474 |
Vacation Cottage | ||
- Per peson | 50 | 189 |
Youth and Recreation Camps | ||
- Per person | 50 | 189 |
Sewer Size | Minimum Slope in Feet Per 100 Feet |
8 | 0.40 |
10 | 0.28 |
12 | 0.22 |
15 | 0.15 |
18 | 0.12 |
21 | 0.10 |
24 | 0.08 |
27 | 0.067 |
30 | 0.058 |
36 | 0.046 |
![]() |
26,500 = 200 130 |
Group | Percent of Slope | Front Yard (ft.) | Side Yard in Percentage of lot width | Right of Way (ft.) | Pavement (ft.) |
1 | 15 + 25 | 25 | 10 | 50 | 24 |
2 | 26-30 | 23 | 10 | 50 | 24 |
3 | 31-Over | 20 | 10 | 50 | 24 |