Intensity Regulations
Yard Minimum | Maximum Building Height | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
District | Minimum Area (acres) | Lot Frontage (feet) | Front | Side | Rear | Stories | Feet | Maximum Coverage by Building | ||
Residence R-1 | 1 | 150 | 40 | 25 | 40 | 2.5 | 35 | 10% | ||
Residence R-3 | 3 | 225 | 40 | 25 | 40 | 2.5 | 35 | 10% | ||
Residence R-D | 1/2 | 100 | 30 | 15 | 20 | 2.5 | 35 | 25% | ||
Commercial C | 1/2 | 100 | 30 | 15 | 40 | 2.5 | 35 | 30% | ||
Manufacturing M | 3 | 225 | 100 | 15 | 50 | 2.5 | 35 | 20% | ||
VCOD | 0.10 | 50 | 5 (1,2,3) | 3 (3,4) | 15 (3) | 2.5 | 35 | 75% | ||
MOD | 1/2 | 100 | 30 | 15 | 40 | 2.5 | 35 | 30% | ||
FOOTNOTES | |
1. | The five-foot setback is only applicable "as of right" to buildings or uses with less than 4,500 square feet gross floor area. |
2. | The front setback may be reduced by special permit, as provided for by Section 4.10, to less than five feet where a sidewalk exists along the street and at least one entrance to the building is located along the sidewalk. |
3. | For buildings or uses greater than 4,500 square feet in gross floor area, the setback requirements of the underlying Commercial District shall apply, except that the underlying Commercial District setback requirements may be reduced by special permit as provided for by Section 4.10. |
4. | Total setback of both sides shall be equal to six feet. The total may be all on one side, all on the other side, or divided in any proportion. |
5. | Ground-mounted solar photovoltaic installations shall meet yard setback requirements, except that setback requirements may be reduced by special permit as a part of the special permit granted for the underlying use. |
6. | Solar energy systems shall not be included in calculations for lot coverage or impervious surface. |
7. | Ground-mounted solar energy generation systems at any scale shall not exceed 15 feet above the ground as measured under each panel module, except the overall height of tracking-type systems may exceed 20 feet for transient conditions when dumping snow. |
8. | The size of a small-scale solar photovoltaic system, defined as having a total collector area of 750 square feet or less, may be increased by the SPGA per Subsection 9.2.6. |
Exceptions to Rules in Table of Dimensional Requirements: | |
1. | Side yards and/or rear yards of commercial or manufacturing uses shall be at least 50 feet when adjacent to a Residence District. |
2. | When a side or rear yard borders on a street, the minimum distance between the street and any type of building shall be as follows: R-3, 40 feet; R-D, 30 feet; C, 10 feet; M, 100 feet; and R-1, 35 feet. |
Intensity Regulations
Yard Minimum | Maximum Building Height | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
District | Minimum Area (acres) | Lot Frontage (feet) | Front | Side | Rear | Stories | Feet | Maximum Coverage by Building | ||
Residence R-1 | 1 | 150 | 40 | 25 | 40 | 2.5 | 35 | 10% | ||
Residence R-3 | 3 | 225 | 40 | 25 | 40 | 2.5 | 35 | 10% | ||
Residence R-D | 1/2 | 100 | 30 | 15 | 20 | 2.5 | 35 | 25% | ||
Commercial C | 1/2 | 100 | 30 | 15 | 40 | 2.5 | 35 | 30% | ||
Manufacturing M | 3 | 225 | 100 | 15 | 50 | 2.5 | 35 | 20% | ||
VCOD | 0.10 | 50 | 5 (1,2,3) | 3 (3,4) | 15 (3) | 2.5 | 35 | 75% | ||
MOD | 1/2 | 100 | 30 | 15 | 40 | 2.5 | 35 | 30% | ||
FOOTNOTES | |
1. | The five-foot setback is only applicable "as of right" to buildings or uses with less than 4,500 square feet gross floor area. |
2. | The front setback may be reduced by special permit, as provided for by Section 4.10, to less than five feet where a sidewalk exists along the street and at least one entrance to the building is located along the sidewalk. |
3. | For buildings or uses greater than 4,500 square feet in gross floor area, the setback requirements of the underlying Commercial District shall apply, except that the underlying Commercial District setback requirements may be reduced by special permit as provided for by Section 4.10. |
4. | Total setback of both sides shall be equal to six feet. The total may be all on one side, all on the other side, or divided in any proportion. |
5. | Ground-mounted solar photovoltaic installations shall meet yard setback requirements, except that setback requirements may be reduced by special permit as a part of the special permit granted for the underlying use. |
6. | Solar energy systems shall not be included in calculations for lot coverage or impervious surface. |
7. | Ground-mounted solar energy generation systems at any scale shall not exceed 15 feet above the ground as measured under each panel module, except the overall height of tracking-type systems may exceed 20 feet for transient conditions when dumping snow. |
8. | The size of a small-scale solar photovoltaic system, defined as having a total collector area of 750 square feet or less, may be increased by the SPGA per Subsection 9.2.6. |
Exceptions to Rules in Table of Dimensional Requirements: | |
1. | Side yards and/or rear yards of commercial or manufacturing uses shall be at least 50 feet when adjacent to a Residence District. |
2. | When a side or rear yard borders on a street, the minimum distance between the street and any type of building shall be as follows: R-3, 40 feet; R-D, 30 feet; C, 10 feet; M, 100 feet; and R-1, 35 feet. |