At the discretion of the applicant, a development application within the R-3 district shall be subject to either:
A.
Conventional Zoning.
1.
Lot Area. The lot area shall be a minimum of 6,000 square feet with corner lots being a minimum of 7,000 square feet.
2.
Lot Width. The minimum width of a lot shall be 60 feet, with corner lots being a minimum of 70 feet in width.
3.
Lot Depth. No requirement.
4.
Front Yard. The front yard shall be a minimum of 20 feet.
5.
Side Yard. The side yard shall be a minimum of five feet per story. Side yards abutting a street shall be a minimum of 10 feet; provided, that side yards abutting streets shall comply with the following:
a.
Sight distance and clear vision area requirements set forth in the public works standards;
b.
Special setback rules set forth in § 17.60.090; and
c.
For structures or a part of any structure served by a driveway located on the side yard, the minimum side yard setback, for that part of the structure serving the driveway, such as a garage or carport, shall be 20 feet.
6.
Rear Yard. The rear yard shall be a minimum of 10 feet.
7.
Lot Coverage. The maximum permitted aggregate building coverage shall be 50% of the lot area.
8.
Special Yards and Distances Between Buildings.
a.
The distance between any principal building and detached accessory building shall be a minimum of 10 feet.
b.
An inner court providing access to double-row dwelling group units or clustered units shall be a minimum of 20 feet in width.
c.
The distance between principal buildings shall be at least one-half the sum of the heights of both buildings; provided, that in no case shall the distance be less than 12 feet.
9.
Density. All development within the R-3 district shall comply with the following minimum and maximum density requirements:
a.
Minimum density: 14 units per net acre; and
b.
Maximum density: 25 units per net acre.
The term "net acre" is defined as the project area less all dedicated public areas.
10.
Notwithstanding the yard requirements above and depending on the location of the lot, special setback requirements may apply as specified in § 17.60.090.
B.
Performance Zoning. With the exception of the density requirements in subsection (A)(9) of this section, at the discretion of the applicant, a development application within the R-3 zoning district shall be subject to the following site development standards:
1.
The normal base zone requirements as identified in this chapter; or
2.
The TOD-MMR site development and design requirements as set forth in Chapter 17.65, TOD Overlay.
(Ord. 1436 § 2(part), 1981; Ord. 1615 § 25, 1989; Ord. 1723 § 4, 1995; Ord. 1738 § 4, 1996; Ord. 1912 § 3(part), 2008; Ord. 2034 § 5, 2017; Ord. 2100 § 7, 2023; Ord. 2136, 1/8/2026)