Zoneomics Logo
search icon

Crestview Hills City Zoning Code

APPENDIX A

ZONE REGULATIONS SUMMARY

TABLE A-1 ZONE REGULATIONS SUMMARY -- RESIDENTIAL ZONES
ZONE REQUIREMENTSCOR-1BcR-1CR-1DR-1ER-2aR-2bR-PUD
Minimum Lot Area (in square feet)(3)15,00012,5009,0007,50012,500 for each two dwelling unit building20,000 - first 4 units; 5,000 each additional unit50 acres4
7,500 - SF
16,000 - MF
Density – Dwelling Units Per Net Acre(3)2.93.54.85.878.74.5 Gross Acre
Minimum Lot Width At Minimum Building Setback Line (in feet)(3)100807060100100(5)
Minimum Lot Depth(3)150150125125----(5)
Minimum Front Yard Depth (in feet)(3)504540354040(5)
Minimum Side Yard Width On Back Side Of Lot (in feet)(3)108551015(5)
Minimum Rear Yard Depth (in feet)(3)505050353030(5)
Maximum Building Height(3)

35 feet or

2-1/2 stories

35 feet or

2-1/2 stories

35 feet or

2-1/2 stories

35 feet or

2-1/2 stories

40 feet or

2 stories

40 feet or

3 stories

35 feet or

2-1/2 stories

Site Plan Required (SECTION 9.19)x--------xxx
Minimum Living Area In Residence Required (in square feet)        
 Ranch Style Home--1,7501,5001,2001,100------
 Minimum Main Floor--1,000950850750------
 Second Level Allowance1--2/32/32/32/3------
 Garage Allowance2        
 Maximum Percent Counted--25252525------
 Not to Exceed (in square feet)--12512512565------
  1. Only that portion of the second level is counted which has a ceiling height of 7’-6” or more. Second level does not include basements.
  2. Garage allowance (counted towards minimum living area in residence) applies only to attached garages.
  3. As approved by the planning commission, according to the site plan.
  4. Development of a smaller tract adjacent to an existing RCD Zone may be permitted when approved by the planning commission if the proposed development conforms to and extends the original development.
  5. As approved according to the Final development Plan.
TABLE A-1 ZONE REGULATIONS SUMMARY -- RESIDENTIAL ZONES
ZONE REQUIREMENTSCOR-1BcR-1CR-1DR-1ER-2aR-2bR-PUD
Minimum Lot Area (in square feet)(3)15,00012,5009,0007,50012,500 for each two dwelling unit building20,000 - first 4 units; 5,000 each additional unit50 acres4
7,500 - SF
16,000 - MF
Density – Dwelling Units Per Net Acre(3)2.93.54.85.878.74.5 Gross Acre
Minimum Lot Width At Minimum Building Setback Line (in feet)(3)100807060100100(5)
Minimum Lot Depth(3)150150125125----(5)
Minimum Front Yard Depth (in feet)(3)504540354040(5)
Minimum Side Yard Width On Back Side Of Lot (in feet)(3)108551015(5)
Minimum Rear Yard Depth (in feet)(3)505050353030(5)
Maximum Building Height(3)

35 feet or

2-1/2 stories

35 feet or

2-1/2 stories

35 feet or

2-1/2 stories

35 feet or

2-1/2 stories

40 feet or

2 stories

40 feet or

3 stories

35 feet or

2-1/2 stories

Site Plan Required (SECTION 9.19)x--------xxx
Minimum Living Area In Residence Required (in square feet)        
 Ranch Style Home--1,7501,5001,2001,100------
 Minimum Main Floor--1,000950850750------
 Second Level Allowance1--2/32/32/32/3------
 Garage Allowance2        
 Maximum Percent Counted--25252525------
 Not to Exceed (in square feet)--12512512565------
  1. Only that portion of the second level is counted which has a ceiling height of 7’-6” or more. Second level does not include basements.
  2. Garage allowance (counted towards minimum living area in residence) applies only to attached garages.
  3. As approved by the planning commission, according to the site plan.
  4. Development of a smaller tract adjacent to an existing RCD Zone may be permitted when approved by the planning commission if the proposed development conforms to and extends the original development.
  5. As approved according to the Final development Plan.
TABLE A-1 ZONE REGULATIONS SUMMARY -- RESIDENTIAL ZONES
ZONE REQUIREMENTSCOR-1BcR-1CR-1DR-1ER-2aR-2bR-PUD
Minimum Lot Area (in square feet)(3)15,00012,5009,0007,50012,500 for each two dwelling unit building20,000 - first 4 units; 5,000 each additional unit50 acres4
7,500 - SF
16,000 - MF
Density – Dwelling Units Per Net Acre(3)2.93.54.85.878.74.5 Gross Acre
Minimum Lot Width At Minimum Building Setback Line (in feet)(3)100807060100100(5)
Minimum Lot Depth(3)150150125125----(5)
Minimum Front Yard Depth (in feet)(3)504540354040(5)
Minimum Side Yard Width On Back Side Of Lot (in feet)(3)108551015(5)
Minimum Rear Yard Depth (in feet)(3)505050353030(5)
Maximum Building Height(3)

35 feet or

2-1/2 stories

35 feet or

2-1/2 stories

35 feet or

2-1/2 stories

35 feet or

2-1/2 stories

40 feet or

2 stories

40 feet or

3 stories

35 feet or

2-1/2 stories

Site Plan Required (SECTION 9.19)x--------xxx
Minimum Living Area In Residence Required (in square feet)        
 Ranch Style Home--1,7501,5001,2001,100------
 Minimum Main Floor--1,000950850750------
 Second Level Allowance1--2/32/32/32/3------
 Garage Allowance2        
 Maximum Percent Counted--25252525------
 Not to Exceed (in square feet)--12512512565------
  1. Only that portion of the second level is counted which has a ceiling height of 7’-6” or more. Second level does not include basements.
  2. Garage allowance (counted towards minimum living area in residence) applies only to attached garages.
  3. As approved by the planning commission, according to the site plan.
  4. Development of a smaller tract adjacent to an existing RCD Zone may be permitted when approved by the planning commission if the proposed development conforms to and extends the original development.
  5. As approved according to the Final development Plan.
TABLE A-1 ZONE REGULATIONS SUMMARY -- RESIDENTIAL ZONES
ZONE REQUIREMENTSCOR-1BcR-1CR-1DR-1ER-2aR-2bR-PUD
Minimum Lot Area (in square feet)(3)15,00012,5009,0007,50012,500 for each two dwelling unit building20,000 - first 4 units; 5,000 each additional unit50 acres4
7,500 - SF
16,000 - MF
Density – Dwelling Units Per Net Acre(3)2.93.54.85.878.74.5 Gross Acre
Minimum Lot Width At Minimum Building Setback Line (in feet)(3)100807060100100(5)
Minimum Lot Depth(3)150150125125----(5)
Minimum Front Yard Depth (in feet)(3)504540354040(5)
Minimum Side Yard Width On Back Side Of Lot (in feet)(3)108551015(5)
Minimum Rear Yard Depth (in feet)(3)505050353030(5)
Maximum Building Height(3)

35 feet or

2-1/2 stories

35 feet or

2-1/2 stories

35 feet or

2-1/2 stories

35 feet or

2-1/2 stories

40 feet or

2 stories

40 feet or

3 stories

35 feet or

2-1/2 stories

Site Plan Required (SECTION 9.19)x--------xxx
Minimum Living Area In Residence Required (in square feet)        
 Ranch Style Home--1,7501,5001,2001,100------
 Minimum Main Floor--1,000950850750------
 Second Level Allowance1--2/32/32/32/3------
 Garage Allowance2        
 Maximum Percent Counted--25252525------
 Not to Exceed (in square feet)--12512512565------
  1. Only that portion of the second level is counted which has a ceiling height of 7’-6” or more. Second level does not include basements.
  2. Garage allowance (counted towards minimum living area in residence) applies only to attached garages.
  3. As approved by the planning commission, according to the site plan.
  4. Development of a smaller tract adjacent to an existing RCD Zone may be permitted when approved by the planning commission if the proposed development conforms to and extends the original development.
  5. As approved according to the Final development Plan.
TABLE A-2
MINIMUM SETBACK REQUIREMENTS FOR ADJACENT ZONES
PROVIDERSABUTS PROPERTY IN ONE OF THESE ZONES. THE FOLLOWING SCREENING AND SETBACK SHALL BE PROVIDED
Where any yard of any use permitted or conditionally permitted in one of these following zones:All R-1 ZonesR-2, R-2a, R-2b, R-3, R-4RMHPR=PUDGC, NC, HLC, CBD, PO, PO-1, PO-2, HCSC, NSCIP, I-1, I-2, I-4I-3
Min. Set-backScreening RequiredMin. Set-backScreening RequiredMin. Set-backScreening RequiredMin. Set-backScreening RequiredMin. Set-backScreening RequiredMin. Set-backScreening RequiredMin. Set-backScreening RequiredMin. Set-backScreening Required
All R-1 (Single and Two-Family Zones)113*No*3*No*3*No*3No*3*No*3*No*3*No*
R-2a, R-2b, R-2, R-3 (Multi-Family Zones)30 feetYes3No30 feetYes3No*3No*3*No*3*No*3*No*
RMHP (Residential Mobile Home Park Overlay Zone)2222222222222222
R-PUD (Planned Unit Development Overlay Zone)2222222222222222

GC, NC, HLC, CBD, PO,

PO-1, PO-2, HC (Commercial Zones)

60 feetYes60 feetYes50 feetYes60 feetYes3No3No3*No*3*No*
SC, NBC (Shopping Center Zones)75 feetYes75 feetYes75 feetYes75 feetYes3No3No3*No*3*No*
IP, I-1, I-2, I-4 (Industrial Zones)75 feetYes75 feetYes75 feetYes75 feetYes30 feetYes30 feetYes3No3*No*
I-3 (Industrial-Mining Zone)200 feetYes200 feetYes200 feetYes200 feetYes200 feetNo200 feetNo200 feetNo3No
  1. No special provision other than the minimum yard and setback regulations required for all permitted and conditionally permitted uses, except where any yard of a conditional use abuts property in this zone, screening shall be provided according to the regulations of SECTION 9.17 and minimum setback shall be fifty (50) feet.
  2. As determined by the planning commission to an approved plan.
  3.  No special provision other than the minimum yard and setback regulations required for all permitted and conditionally permitted uses.
* In the case of a change in the zoning map which results in these two zones becoming adjacent, when such was not the case prior to the zone change, and when development has already occurred on the property adjacent to said area in which the zoning has been changed, then said area shall provide the same screening and/or minimum setbacks that would be required, according to this table of the adjacent property which has already been developed.
TABLE A-2
MINIMUM SETBACK REQUIREMENTS FOR ADJACENT ZONES
PROVIDERSABUTS PROPERTY IN ONE OF THESE ZONES. THE FOLLOWING SCREENING AND SETBACK SHALL BE PROVIDED
Where any yard of any use permitted or conditionally permitted in one of these following zones:All R-1 ZonesR-2, R-2a, R-2b, R-3, R-4RMHPR=PUDGC, NC, HLC, CBD, PO, PO-1, PO-2, HCSC, NSCIP, I-1, I-2, I-4I-3
Min. Set-backScreening RequiredMin. Set-backScreening RequiredMin. Set-backScreening RequiredMin. Set-backScreening RequiredMin. Set-backScreening RequiredMin. Set-backScreening RequiredMin. Set-backScreening RequiredMin. Set-backScreening Required
All R-1 (Single and Two-Family Zones)113*No*3*No*3*No*3No*3*No*3*No*3*No*
R-2a, R-2b, R-2, R-3 (Multi-Family Zones)30 feetYes3No30 feetYes3No*3No*3*No*3*No*3*No*
RMHP (Residential Mobile Home Park Overlay Zone)2222222222222222
R-PUD (Planned Unit Development Overlay Zone)2222222222222222

GC, NC, HLC, CBD, PO,

PO-1, PO-2, HC (Commercial Zones)

60 feetYes60 feetYes50 feetYes60 feetYes3No3No3*No*3*No*
SC, NBC (Shopping Center Zones)75 feetYes75 feetYes75 feetYes75 feetYes3No3No3*No*3*No*
IP, I-1, I-2, I-4 (Industrial Zones)75 feetYes75 feetYes75 feetYes75 feetYes30 feetYes30 feetYes3No3*No*
I-3 (Industrial-Mining Zone)200 feetYes200 feetYes200 feetYes200 feetYes200 feetNo200 feetNo200 feetNo3No
  1. No special provision other than the minimum yard and setback regulations required for all permitted and conditionally permitted uses, except where any yard of a conditional use abuts property in this zone, screening shall be provided according to the regulations of SECTION 9.17 and minimum setback shall be fifty (50) feet.
  2. As determined by the planning commission to an approved plan.
  3.  No special provision other than the minimum yard and setback regulations required for all permitted and conditionally permitted uses.
* In the case of a change in the zoning map which results in these two zones becoming adjacent, when such was not the case prior to the zone change, and when development has already occurred on the property adjacent to said area in which the zoning has been changed, then said area shall provide the same screening and/or minimum setbacks that would be required, according to this table of the adjacent property which has already been developed.
TABLE A-2
MINIMUM SETBACK REQUIREMENTS FOR ADJACENT ZONES
PROVIDERSABUTS PROPERTY IN ONE OF THESE ZONES. THE FOLLOWING SCREENING AND SETBACK SHALL BE PROVIDED
Where any yard of any use permitted or conditionally permitted in one of these following zones:All R-1 ZonesR-2, R-2a, R-2b, R-3, R-4RMHPR=PUDGC, NC, HLC, CBD, PO, PO-1, PO-2, HCSC, NSCIP, I-1, I-2, I-4I-3
Min. Set-backScreening RequiredMin. Set-backScreening RequiredMin. Set-backScreening RequiredMin. Set-backScreening RequiredMin. Set-backScreening RequiredMin. Set-backScreening RequiredMin. Set-backScreening RequiredMin. Set-backScreening Required
All R-1 (Single and Two-Family Zones)113*No*3*No*3*No*3No*3*No*3*No*3*No*
R-2a, R-2b, R-2, R-3 (Multi-Family Zones)30 feetYes3No30 feetYes3No*3No*3*No*3*No*3*No*
RMHP (Residential Mobile Home Park Overlay Zone)2222222222222222
R-PUD (Planned Unit Development Overlay Zone)2222222222222222

GC, NC, HLC, CBD, PO,

PO-1, PO-2, HC (Commercial Zones)

60 feetYes60 feetYes50 feetYes60 feetYes3No3No3*No*3*No*
SC, NBC (Shopping Center Zones)75 feetYes75 feetYes75 feetYes75 feetYes3No3No3*No*3*No*
IP, I-1, I-2, I-4 (Industrial Zones)75 feetYes75 feetYes75 feetYes75 feetYes30 feetYes30 feetYes3No3*No*
I-3 (Industrial-Mining Zone)200 feetYes200 feetYes200 feetYes200 feetYes200 feetNo200 feetNo200 feetNo3No
  1. No special provision other than the minimum yard and setback regulations required for all permitted and conditionally permitted uses, except where any yard of a conditional use abuts property in this zone, screening shall be provided according to the regulations of SECTION 9.17 and minimum setback shall be fifty (50) feet.
  2. As determined by the planning commission to an approved plan.
  3.  No special provision other than the minimum yard and setback regulations required for all permitted and conditionally permitted uses.
* In the case of a change in the zoning map which results in these two zones becoming adjacent, when such was not the case prior to the zone change, and when development has already occurred on the property adjacent to said area in which the zoning has been changed, then said area shall provide the same screening and/or minimum setbacks that would be required, according to this table of the adjacent property which has already been developed.
TABLE A-2
MINIMUM SETBACK REQUIREMENTS FOR ADJACENT ZONES
PROVIDERSABUTS PROPERTY IN ONE OF THESE ZONES. THE FOLLOWING SCREENING AND SETBACK SHALL BE PROVIDED
Where any yard of any use permitted or conditionally permitted in one of these following zones:All R-1 ZonesR-2, R-2a, R-2b, R-3, R-4RMHPR=PUDGC, NC, HLC, CBD, PO, PO-1, PO-2, HCSC, NSCIP, I-1, I-2, I-4I-3
Min. Set-backScreening RequiredMin. Set-backScreening RequiredMin. Set-backScreening RequiredMin. Set-backScreening RequiredMin. Set-backScreening RequiredMin. Set-backScreening RequiredMin. Set-backScreening RequiredMin. Set-backScreening Required
All R-1 (Single and Two-Family Zones)113*No*3*No*3*No*3No*3*No*3*No*3*No*
R-2a, R-2b, R-2, R-3 (Multi-Family Zones)30 feetYes3No30 feetYes3No*3No*3*No*3*No*3*No*
RMHP (Residential Mobile Home Park Overlay Zone)2222222222222222
R-PUD (Planned Unit Development Overlay Zone)2222222222222222

GC, NC, HLC, CBD, PO,

PO-1, PO-2, HC (Commercial Zones)

60 feetYes60 feetYes50 feetYes60 feetYes3No3No3*No*3*No*
SC, NBC (Shopping Center Zones)75 feetYes75 feetYes75 feetYes75 feetYes3No3No3*No*3*No*
IP, I-1, I-2, I-4 (Industrial Zones)75 feetYes75 feetYes75 feetYes75 feetYes30 feetYes30 feetYes3No3*No*
I-3 (Industrial-Mining Zone)200 feetYes200 feetYes200 feetYes200 feetYes200 feetNo200 feetNo200 feetNo3No
  1. No special provision other than the minimum yard and setback regulations required for all permitted and conditionally permitted uses, except where any yard of a conditional use abuts property in this zone, screening shall be provided according to the regulations of SECTION 9.17 and minimum setback shall be fifty (50) feet.
  2. As determined by the planning commission to an approved plan.
  3.  No special provision other than the minimum yard and setback regulations required for all permitted and conditionally permitted uses.
* In the case of a change in the zoning map which results in these two zones becoming adjacent, when such was not the case prior to the zone change, and when development has already occurred on the property adjacent to said area in which the zoning has been changed, then said area shall provide the same screening and/or minimum setbacks that would be required, according to this table of the adjacent property which has already been developed.

Effective on: 1/1/1901