15-6A-1: PERMITTED USES:

Table No. 1 below contains the uses permitted in the M-1 and M-2 zones, including uses permitted by right, accessory uses, uses subject to an administrative use permit and uses subject to a conditional use permit
   Table No. 1 - permitted uses in industrial zones
Uses
Zones
M-1
M-2
Uses
Zones
M-1
M-2
Eating and drinking establishments
Drive-through restaurants
CUP
CUP
Restaurants and cafes
P
CUP
General Commercial uses
Adult-oriented businesses
Alcohol - off-site sale at limited support service retail establishments.
AUP
AUP
Alcohol - on-site sale and consumption at restaurants and delicatessens
AUP
AUP
Animal boarding
CUP
CUP
Animal hospitals (and veterinary services)
P
CUP
Billiard/pool rooms and bowling alleys
CUP
CUP
Business and consumer support services
CUP
CUP
Drive-through or walk-up services, excluding drive-through restaurants.
A
A
Financial institutions
CUP
CUP
Fitness centers
P
CUP
General offices
P
CUP
Medical-dental offices
CUP
CUP
Medical-dental laboratories
CUP
CUP
Motion picture/television production facilities (indoor)1
CUP
CUP
Multi-media offices
CUP
CUP
Office worker-oriented services, not located on Pacific Coast Highway or El Segundo Boulevard
CUP
CUP
Personal services
CUP
CUP
Retail sales
CUP
CUP
Service stations2
CUP
CUP
Group care and hospitality uses
Daycare centers
P
CUP
Dog daycare (indoor)
P
Dog daycare (outdoor)
CUP
CUP
Emergency shelters, per ESMC Section 15-6A-11
P
Hotels and motels
CUP
CUP
Low-barrier navigation centers, pursuant to ESMC 15-37A
P
Industrial
Construction yards
P
Extraction of raw materials and refining
P
Factories
P
Freight forwarding, transfer, trucking yards or terminals
CUP
CUP
General storage, warehousing and ministorage
P
Generating stations
P
Heavy manufacturing uses
P
High and medium bay labs
P
Light manufacturing uses and related offices
P
Research and development
P
CUP
Waste material transfer and storage
N
N
Wholesale uses
CUP
CUP
Institutional
Government buildings/public uses
P
CUP
Schools
CUP
CUP
Miscellaneous uses
Data centers
CUP
CUP
Helicopter landing facilities, per ESMC section 15-2-13 
CUP
CUP
Medium and large-scale ground-mounted solar energy systems
P
P
Open storage of commodities sold or utilized on the premises.
A
A
Outdoor dining areas, per ESMC Chapter 15-2
A
A
Public utilities, including, but not limited to, power substations and telephone exchanges
P
Residential Uses
N
N
Recreational facilities (public and private)
P
CUP
Roof-mounted solar energy systems.
A
A
Small and medium-scale ground-mounted solar energy systems.
A
A
Any use customarily incidental to a permitted use
A
A
Other similar uses approved by the Director, per ESMC Chapter 15-22
P, A, AUP, CUP, N
P, A, AUP, CUP, N
 
Notes:
   1.   P = Permitted use, A = Accessory use, AUP = Use subject to an administrative use permit (Per ESMC Chapters 23 and 23), CUP = Use subject to a conditional use permit (per ESMC Chapters 24 and 28), N = prohibited
   2.   Service stations are permitted with a CUP if located a minimum of 500 feet from any residential zoned property. This distance criteria does not apply to properties east of Pacific Coast Highway.
(Ord. 1648, 6-21-2023; amd. Ord. 1653, 12-5-2023; Ord. 1654, 12-19-2023)

15-6B-1: PURPOSE:

The purpose of this zone is to provide consistency with and implement policies related to those locations which are designated Light Industrial on the General Plan land use map and in the General Plan text. This zone is intended to provide for the location and grouping of light industrial activities, research, and technological processes, and related offices and auxiliary uses performing support services for existing and permitted establishments, companies or business firms within the zone. (Ord. 1648, 6-21-2023)

15-6B-2: PERMITTED USES:

Permitted uses, permitted accessory uses, uses subject to administrative use permit, and uses subject to conditional use permit for all industrial zones are listed in Article 15-6A of this Title. (Ord. 1648, 6-21-2023)

15-6B-3: SITE DEVELOPMENT STANDARDS:

All uses within the M-1 Zone shall comply with the development standards contained in this section.
   A.   General Provisions:
      1.   No operations and uses conducted on the premises shall be in violation of this Code, State laws, or environmental regulations by reason of noise, odor, dust, mud, smoke, light, vibrations or other similar causes.
      2.   All uses in the M-1 Zone shall be conducted completely within a fully enclosed building except:
         a.   Recreational facilities customarily undertaken in the open;
         b.   Special uses, provided such use expressly permits operation in other than a fully enclosed building as provided through an administrative determination; and
         c.   Outdoor restaurant seating, provided it complies with the provisions of section 15-2-16 of this title.
      3.   Prior to approval of any development project, all criteria of the Transportation Demand Management (TDM) and trip reduction criteria, as provided for in chapter 16 of this title shall be met.
      4.   Other provisions as required in chapter 2 of this title.
   B.   Lot area: A minimum of 10,000 square feet.
   C.   Height:
      1.   Buildings and structures shall not exceed a height of 200 feet.
      2.   A maximum grade differential of eight feet is permitted on sloping lots. The vertical height which exceeds the maximum grade differential limit is included in measuring the maximum building height. On sloped lots, a segmented grade plane may be applied to different portions of a building.
      3.   See section 15-2-3 of this title for exceptions to building height.
   D.   Setbacks:
      1.   Front Yard: A minimum of 25 feet.
      2.   Side Yard: A minimum of 15 feet, unless the side yard adjoins a dedicated street, in which case the side yard setback shall be a minimum of 25 feet.
      3.   Rear Yard: A minimum of 10 feet, unless the rear yard adjoins an alley, dedicated street, public right-of-way, or if the primary access is through the rear yard, in which case the rear yard setback shall be a minimum of 25 feet.
   E.   Lot Frontage: A minimum frontage of 100 feet shall be provided on a dedicated street.
   F.   Building Area: The total net "floor area" of all buildings, as defined in section 15-1-6 of this title, on any parcel or lot shall not exceed the total square footage of the parcel or lot area multiplied by 0.6, thereby giving a floor area ratio (FAR) of 0.6:1. However, additional FAR may be granted by the City upon the preparation and approval of a specific plan, consistent with section 65450 et seq., of the California Government Code, or, for properties east of Pacific Coast Highway only, with the approval of a transfer of development rights (TDR) plan. The total net floor area of high and medium bay labs may be multiplied by a factor of 0.5 to determine the allowed net floor area, if an agreement is recorded which ensures that the use and the number of employees is consistent with the definition of "high and medium bay labs" in section 15-1-6 of this title.
   G.   Walls and fences: Walls and fences in the M-1 Zone shall comply with the requirements of chapter 2 of this title.
   H.   Access: All development projects shall provide adequate access and facilities for various modes of transit, as required by the City's transportation demand management program in chapter 16 of this title. In addition, all development projects shall provide pedestrian access between buildings and transit facilities located on site and/or off site if within adjoining public rights-of-way. If the building is part of a multi-building development project, then safe and convenient pedestrian access shall be provided between buildings. (Ord. 1648, 6-21-2023)

15-6B-4: LANDSCAPING:

As required by section 15-2-14 and chapter 15A of this title. (Ord. 1648, 6-21-2023)

15-6B-5: OFF STREET PARKING AND LOADING SPACES:

As required by chapter 15 of this title.

15-6B-6: SIGNS:

As required by chapter 18 of this title. (Ord. 1648, 6-21-2023)

15-6B-7: EMERGENCY SHELTERS DEVELOPMENT STANDARDS:

   A.   Emergency Shelters: Emergency shelters are subject to the following, objective development standards:
      1.   Not more than one emergency shelter is permitted within a radius of three hundred feet (300') from another emergency shelter.
      2.   Not more than twelve (12) persons can be served on a nightly basis.
      3.   Maximum length of stay of a person in an emergency shelter is limited to one hundred and eighty (180) days in any twelve (12)-month period.
      4.   Each emergency shelter must have an on-site management office, with at least one manager present at all times the emergency shelter is in operation.
      5.   Each emergency shelter must have on site security employees, with at least one security employee present at all times the emergency shelter is in operation.
      6.   Staging drop off, intake, and pick up of emergency shelter clients must take place inside a building, at a rear or side entrance not adjacent to a public right-of-way, or in an interior courtyard. Any exterior waiting areas must be physically and visually separated from public view of a right-of-way with a minimum six-foot tall decorative masonry wall and/or a six-foot tall hedge or similar mature landscaping as approved by the Director. Floor plans for the emergency shelter must be submitted with the building plans that show the size and location of any proposed interior and/or exterior waiting or resident intake areas.
      7.   Off street parking must be provided as set forth in this Code, except that the number of off street parking spaces provided must be one parking space per employee on duty with a minimum of three employee parking spaces. Notwithstanding this requirement, the required number of off street parking spaces cannot exceed the spaces required for similar uses of the same size in the M-1 Zone.
      8.   Exterior lighting must be provided at all building entrances and outdoor activity areas, and must be activated between sunset and sunrise of each day. All exterior lighting must comply with this Code. (Ord. 1648, 6-21-2023; amd. Ord. 1654, 12-19-2023)

15-6C-1: PURPOSE:

To provide consistency with and implement policies related to those locations which are designated heavy industrial on the general plan land use map and in the general plan text. This zone is intended to provide areas suitable for the development of heavy manufacturing, assembling, or processing activities having unusual or potentially deleterious operational characteristics, that would be detrimental if allowed to operate in other zones within the city. (Ord. 1648, 6-21-2023)

15-6C-2: PERMITTED USES:

Permitted uses, permitted accessory uses, uses subject to administrative use permit, and uses subject to conditional use permit for all industrial zones are listed in Article 15-6A of this Title. (Ord. 1648, 6-21-2023)

15-6C-3: SITE DEVELOPMENT STANDARDS:

All uses within the M-2 Zone shall comply with the development standards contained in this section.
   A.   General Provisions:
      1.   Operations and uses conducted on the premises, which are or may be in violation of this Code, State laws, or environmental regulations by reason of noise, odor, dust, mud, light, smoke, vibrations or other similar causes, shall conform to all City, State and Federal regulations which are designed to protect the health, safety and welfare of the citizens of this City and the employees of the proposed use.
      2.   Prior to approval of any development project, all criteria of the transportation demand management (TDM) and trip reduction criteria, as provided for in chapter 16 of this title shall be met.
      3.   Other provisions as required in chapter 2 of this title.
   B.   Lot area: A minimum of 20,000 square feet.
   C.   Height:
      1.   A maximum of 200 feet.
      2.   A maximum grade differential of eight feet is permitted on sloping lots. The height which exceeds the maximum grade differential limit is included in measuring the maximum building height. On sloped lots, a segmented grade plane may be applied to different portions of a building.
      3.   See section 15-2-3 of this title for exceptions to building height.
   D.   Setbacks:
      1.   Front Yard: 25 feet minimum.
      2.   Side Yard: 15 feet minimum, unless the side yard adjoins a dedicated street, in which case the side yard setback shall be a minimum of 25 feet.
      3.   Rear Yard: 10 feet minimum, unless the rear yard adjoins an alley, dedicated street, or public right-of-way, or if the primary access is through the rear yard, in which case the rear yard setback shall be a minimum of 25 feet.
   E.   Lot frontage: A minimum frontage of 100 feet shall be provided on a dedicated street.
   F.   Building area: The total net "floor area" of all buildings, as defined in section 15-1-6 of this title, on any parcel or lot shall not exceed the total square footage of the parcel or lot area multiplied by 0.6, thereby giving a floor area ratio of 0.6:1.
   G.   Walls and fences: As required by chapter 2 of this title.
   H.   Access: All development projects shall provide adequate access and facilities for various modes of transit, as required by the city's transportation demand management program in chapter 16 of this title. In addition, all development projects shall provide pedestrian access between buildings and transit facilities located on site and/or off site if within adjoining public rights of way. If the building is part of a multi-building development project, then safe and convenient pedestrian access shall be provided between buildings.
   I.   Recreational facilities: All developments greater than 500 acres shall maintain employee recreational facilities subject to the approval of the Director of Community Development and the Director of Public Works. (Ord. 1648, 6-21-2023)

15-6C-4: LANDSCAPING:

As required by section 15-2-14 and chapter 15A of this title. (Ord. 1648, 6-21-2023)

15-6C-5: OFF STREET PARKING AND LOADING SPACES:

As required by chapter 15 of this title. (Ord. 1648, 6-21-2023)

15-6C-6: SIGNS: