Collegetown Zoning
Abbreviation | District | |
|---|---|---|
CR-1 | Collegetown Residential 1 | |
CR-2 | Collegetown Residential 2 | |
CR-3 | Collegetown Residential 3 | |
CR-4 | Collegetown Residential 4 | |
MU-1 | Mixed Use 1 | |
MU-2 | Mixed Use 2 |
Maximum and Minimum Height (in stories and feet) | |||||
|---|---|---|---|---|---|
District | Maximum (stories) | Minimum (stories) | Maximum (feet) | Minimum (feet) | |
CR-1 | 3* | 2 | 35 | 20 | |
CR-2 | 3* | 2 | 35 | 20 | |
CR-3 | 3* | 2 | 35 | 20 | |
CR-4 | 4 | 2 | 45 | 20 | |
MU-1 | 5 | 3 | 70 | 30 | |
MU-2 | 6 | 4 | 80 | 45 | |
NOTES: | ||
|---|---|---|
*Top story limitation. A habitable third story in CR-1, CR-2, and CR-3 Districts must be fully contained within a pitched roof. | ||
Purpose and intent. |
The Collegetown Residential 1-3 (CR-1, CR-2, CR-3) Districts contain predominantly residential structures occupied as single-family homes, as duplexes, or as multiple residences often rented by university students. The intent is to maintain the existing housing stock. Significant redevelopment within these districts is neither anticipated nor encouraged. |
Any new construction shall be similar in form and scale, and the zoning requirements of these districts are intended to protect the character of the established residential neighborhoods. Mandatory architectural elements, such as front porches and pitched roofs, ensure that new construction is in keeping with the existing built environment. All three districts have a maximum building height of three stories, provided that the third story is completely contained within the required pitched roof. In addition, buildings cannot exceed 35 feet in height. |
The Collegetown Residential 1-3 Districts accommodate single-family, two-family, and multifamily uses, depending on the district. Denser residential uses are permitted in those areas closer to central Collegetown. |
LOT SIZE | |||
Area, minimum | |||
1. | One-family detached dwelling | 4,000 square feet | |
2. | Other uses | 5,500 square feet | |
Width at street line, minimum | |||
1. | One-family detached dwelling | 45 feet | |
2. | Other uses | 50 feet | |
LOT COVERAGE | |||
Lot coverage by buildings, maximum | 30% | ||
Green space, minimum | 35% | ||
MINIMUM OFF-STREET PARKING | |||
1. | Residence | ||
a. Up to 3 bed or sleeping rooms per dwelling unit | 1 space | ||
b. 4 and 5 bed or sleeping rooms per dwelling unit | 2 spaces | ||
c. Each additional bed or sleeping room per dwelling unit | 1 space | ||
2. | Home occupation | 1 space | |
3. | Other uses | See § 325-20D(3)(b) | |
PRINCIPAL BUILDING | |||
Front setback, minimum | 10 feet | ||
Side setback, minimum | 5 feet | ||
Rear setback (whichever is less), minimum | 20 feet or 20% of lot depth | ||
Spacing between primary structures on same parcel, minimum | 20 feet | ||
ACCESSORY STRUCTURE | |||
Side setback, minimum | 5 feet | ||
Rear setback, minimum | 5 feet | ||
Square footage of footprint, maximum | 500 square feet | ||
PARKING LOCATION | |||
Garage setback from front facade, minimum | 20 feet | ||
Parking setback | at front facade | ||
PRINCIPAL BUILDING` | ||
Height (stories/feet), maximum | 3/35 | |
Height (stories/feet), minimum | 2/20 | |
Habitable space in the 3rd story must be fully contained within the pitched roof. See § 325-45.2B(11). | ||
ACCESSORY STRUCTURE | ||
Height (stories/feet), maximum | 2/20 | |
FLOOR HEIGHT (PRINCIPAL BUILDING) | ||
Street-level (floor to floor), minimum | 9 feet | |
2nd story (floor to floor), minimum | 9 feet | |
ROOF | ||
Pitched roof | Required | |
Shed roof not allowed as primary roof | ||
Pitch of principal gable, minimum/maximum | 6:12/12:12 | |
LOT SIZE | |||
Area, minimum | |||
1. | One-family or two-family dwelling | 4,000 square feet | |
2. | Other uses | 5,500 square feet | |
Width at street line, minimum | |||
1. | One-family or two-family dwelling | 45 feet | |
2. | Other uses | 50 feet | |
LOT COVERAGE | |||
Lot coverage by buildings, maximum | 35% | ||
Green space, minimum | 35% | ||
MINIMUM OFF-STREET PARKING | |||
1. | Residence | ||
a. Up to 3 bed or sleeping rooms per dwelling unit | 1 space | ||
b. 4 and 5 bed or sleeping rooms per dwelling unit | 2 spaces | ||
c. Each additional bed or sleeping room per dwelling unit | 1 space | ||
2. | Home occupation | 1 space | |
3. | Other uses | See § 325-20D(3)(b) | |
PRINCIPAL BUILDING | ||
Front setback, minimum | 10 feet | |
Side setback, minimum | 5 feet | |
Rear setback (whichever is less), minimum | 20 feet or 20% of lot depth | |
Spacing between primary structures on same parcel, minimum | 20 feet | |
ACCESSORY STRUCTURE | ||
Side setback, minimum | 3 feet | |
Rear setback, minimum | 3 feet | |
Square footage of footprint, maximum | 500 square feet | |
PARKING LOCATION | ||
Garage setback from front facade, minimum | 20 feet | |
Parking setback | at front facade | |
PRINCIPAL BUILDING | ||
Height (stories/feet), maximum | 3/35 | |
Height (stories/feet), minimum | 2/20 | |
Habitable space in the 3rd story must be fully contained within the pitched roof. See § 325-45.2B(11). | ||
ACCESSORY STRUCTURE | ||
Height (stories/feet), maximum | 2/20 | |
FLOOR HEIGHT (PRINCIPAL BUILDING) | ||
Street-level (floor to floor), minimum | 9 feet | |
2nd story (floor to floor), minimum | 9 feet | |
ROOF | ||
Pitched roof | Required | |
Shed roof not allowed as primary roof | ||
Pitch of principal gable, minimum/maximum | 6:12/12:12 | |
LOT SIZE | ||||
Area, minimum | ||||
1. | One-family or two-family dwelling | 3,000 square feet | ||
2. | Multiple dwelling and other uses | 3,500 square feet | ||
Width at street line, minimum | ||||
1. | One-family or two-family dwelling | 30 feet | ||
2. | Multiple dwelling and other uses | 40 feet | ||
LOT COVERAGE | ||||
Lot coverage by buildings, maximum | 40% | |||
Green space, minimum | 30% | |||
MINIMUM OFF-STREET PARKING | ||||
1. | Residence | |||
a. Up to 3 bed or sleeping rooms per dwelling unit | 1 space | |||
b. 4 and 5 bed or sleeping rooms per dwelling unit | 2 spaces | |||
c. Each additional bed or sleeping room per dwelling unit | 1 space | |||
2. | Home occupation | 1 space | ||
3. | Other uses | See § 325-20D(3)(b) | ||
PRINCIPAL BUILDING | ||
Front setback, minimum | 10 feet | |
Side setback, minimum | 5 feet | |
Rear setback (whichever is less), minimum | 20 feet or 20% of lot depth | |
Spacing between primary structures on same parcel, minimum | 10 feet | |
ACCESSORY STRUCTURE | ||
Side setback, minimum | 3 feet | |
Rear setback, minimum | 3 feet | |
Square footage of footprint per unit, maximum | 500 square feet | |
PARKING LOCATION | ||
Garage setback from front facade, minimum | 20 feet | |
Parking setback | at front facade | |
PRINCIPAL BUILDING | ||
Height (stories/feet), maximum | 3/35 | |
Height (stories/feet), minimum | 2/20 | |
Habitable space in the 3rd story must be fully contained within the pitched roof. See § 325-45.2B(11). | ||
ACCESSORY STRUCTURE | ||
Height (stories/feet), maximum | 2/20 | |
FLOOR HEIGHT (PRINCIPAL BUILDING) | ||
Street-level (floor to floor), minimum | 9 feet | |
2nd story (floor to floor), minimum | 9 feet | |
ROOF | ||
Pitched roof | Required | |
Shed roof not allowed as primary roof | ||
Pitch of principal gable, minimum/maximum | 6:12/12:12 | |
Purpose and intent. |
|---|
The Collegetown Residential 4 District primarily contains multifamily dwelling units, and while single-family and two-family residential uses are permitted, it is expected that multifamily residential will remain the predominant use. The intent is this will be a medium-density residential district, consistent with the vision outlined in the 2009 Collegetown Urban Plan and Conceptual Design Guidelines to concentrate additional development in the central areas of Collegetown. |
This district serves as an essential bridge, both in density and built form, between the Collegetown Residential 1-3 and Mixed Use Districts. Redevelopment is encouraged, but it is essential that new construction meet the district requirements to ensure a consistent transition between the higher-density and lower-density zoning districts. District regulations permit buildings of up to four stories and 45 feet in height; a building must meet both requirements. Maximum lot coverage by buildings is greater than in the Collegetown Residential Districts 1-3 but not as high as allowed in the Mixed Use Districts. In terms of form, the district requirements provide property owners with choices between architectural features intended to create buildings compatible with those in adjacent zoning districts. |
LOT SIZE | |||
Area, minimum | |||
1. | One-family or two-family dwelling | 3,000 square feet | |
2. | Multiple dwelling and other uses | 3,500 square feet | |
Width at street line, minimum | |||
1. | One-family or two-family dwelling | 30 feet | |
2. | Multiple dwelling and other uses | 40 feet | |
LOT COVERAGE | |||
Lot coverage by buildings, maximum | 50% | ||
Green space, minimum | 25% | ||
MINIMUM OFF-STREET PARKING | |||
Buildings that fully comply with the New York State | |||
Building Code or Residential Code for new construction: | |||
None, provided a transportation demand management plan is accepted by the Planning and Development Board during site plan review | |||
All other structures: | |||
1. | Residence | ||
a. Up to 3 bed or sleeping rooms per dwelling unit | 1 space | ||
b. 4 and 5 bed or sleeping rooms per dwelling unit | 2 spaces | ||
c. Each additional bed or sleeping room per dwelling unit | 1 space | ||
2. | Home occupation | 1 space | |
3. | Other uses | See § 325-20D(3)(b) | |
PRINCIPAL BUILDING | |||
Front setback, minimum | 10 feet | ||
Side setback, minimum | |||
1. | Row house | 0 feet | |
2. | All other structures | 5 feet | |
Rear setback (whichever is less), minimum | 10 feet or 20% of lot depth | ||
Spacing between primary structures on same parcel, minimum | 5 feet | ||
ACCESSORY STRUCTURE | |||
Side setback, minimum | 3 feet | ||
Rear setback, minimum | 3 feet | ||
Square footage of footprint per unit, maximum | 500 square feet | ||
PARKING LOCATION | |||
Garage setback from front facade, minimum | 20 feet | ||
Parking setback | at front facade | ||
Internal or underground parking must be wrapped by residential on street-facing facades (except for entries/exits) and may not be visible from a public street. | |||
PRINCIPAL BUILDING | ||
Height (stories/feet), maximum | 4/45 | |
Height (stories/feet), minimum | 2/20 | |
ACCESSORY STRUCTURE | ||
Height (stories/feet), maximum | 2/20 | |
FLOOR HEIGHT (PRINCIPAL BUILDING) | ||
Street-level (floor to floor), minimum | 9 feet | |
Upper-story (floor to floor), minimum | 9 feet | |
ROOF | ||
Pitched or flat roof | Allowed | |
STREET FACADE | |||
Building length, primary street, maximum | |||
1. | Row house | 100 feet | |
2. | All other structures | 45 feet | |
Length of blank wall, maximum | 8 feet | ||
DOORS AND ENTRIES | |||
Functioning entry on the street-facing facade, minimum | 1 | ||
For corner lots, one functioning entry is required on the primary street-facing facade. | |||
PORCH, STOOP OR RECESSED ENTRY | |||
Front porch, stoop or recessed entry required for each functional entry | |||
Purpose and intent. |
|---|
The Mixed Use Districts accommodate retail, office, service, hotel, and residential uses, and in most cases, multiple uses will be combined within the same building. The purpose is to create a dynamic urban environment in which uses reinforce each other and promote an attractive, walkable neighborhood. |
Located in central Collegetown, the Mixed Use Districts allow the highest density within the Collegetown Area Form Districts. Redevelopment is anticipated and encouraged (with the exception of designated local landmarks), and the intent is to concentrate the majority of additional development within these districts. |
The Mixed Use District regulations have been designed to encourage exceptional urban design and high-quality construction. The Mixed Use 1 District permits buildings of up to five stories and 70 feet in height while the Mixed Use 2 District allows buildings of up to six stories and 80 feet in height. A building cannot exceed either requirement. While it may be feasible to design a building with a greater number of stories within the maximum allowed height, in feet, the intent of the district regulations is to meet both requirements. The additional building height, in feet, has been allowed for the purpose of providing adequate space for mechanicals and accommodating high-quality design features and finishes. |
An objective of both Mixed Use Districts is to create an urban form that gives priority to pedestrians and encourages year-round commercial activity at the street level. Required form elements, such as a maximum distance between entries and a maximum length of blank wall, activate the street-level of buildings to engage pedestrians through this highly traveled section of Collegetown. In addition, front setback requirements have been incorporated to ensure adequate space to provide wider sidewalks and a safer pedestrian environment. A required ten-foot chamfer or additional setback at corner lots within the Mixed Use 2 District will allow greater visibility and natural light at busy intersections. |
LOT SIZE | |||
Area, minimum | |||
1. | One-family or two-family dwelling | 3,000 square feet | |
2. | Multiple dwelling and other uses | 3,500 square feet | |
Width at street line, minimum | |||
1. | One-family or two-family dwelling | 30 feet | |
2. | Multiple dwelling and other uses | 40 feet | |
LOT COVERAGE | |||
Lot coverage by buildings, maximum | 70% | ||
Green space, minimum | 10% | ||
MINIMUM OFF-STREET PARKING | |||
None | |||
PRINCIPAL BUILDING | |||
Front setback, minimum | 5 feet | ||
Side setback, minimum | 5 feet | ||
1. | Row house | 0 feet | |
2. | All other structures | 5 feet | |
Rear setback, minimum | 10 feet | ||
Spacing between primary structures on same parcel, minimum | 5 feet | ||
ACCESSORY STRUCTURE | |||
Side setback, minimum | 0 feet | ||
Rear setback, minimum | 0 feet | ||
Square footage of footprint per unit, maximum | 500 square feet | ||
PARKING LOCATION | |||
Parking setback, from front facade, minimum | 30 feet | ||
Internal or underground parking must be wrapped by residential on street-facing facades (except for entries/exits) and may not be visible from a public street. | |||
PRINCIPAL BUILDING | |||
Height (stories/feet), maximum | 7/75 | ||
Height (stories/feet), minimum | 3/30 | ||
ACCESSORY STRUCTURE | |||
Height (stories/feet), maximum | 2/20 | ||
FLOOR HEIGHT (PRINCIPAL BUILDING) | |||
Street-level (floor to floor), minimum | |||
1. | Residential | 10 feet | |
2. | Commercial | 12 feet | |
Upper-story (floor to floor), minimum | 10 feet | ||
ROOF | |||
Pitched or flat roof | Allowed | ||
STREET FACADE | |||
Building length, primary street, length, maximum | |||
1. | Row house | 150 feet | |
2. | All other structures | 75 feet | |
Length of blank wall, maximum | 12 feet | ||
DOORS AND ENTRIES | |||
Distance between functioning street-facing entries, maximum | 35 feet | ||
Commercial entries must be functioning and usable during business hours. | |||
RECESSED ENTRY | |||
Recessed entry required for each functional entry | |||
LOT SIZE | ||
Area, minimum | 2,500 square feet | |
Width at street line, minimum | 25 feet | |
LOT COVERAGE | ||
Lot coverage by buildings, maximum | 100%, except as required for rear yard | |
Green space, minimum | 0% | |
MINIMUM OFF-STREET PARKING | ||
None | ||
PRINCIPAL BUILDING* | ||
Front setback, minimum/maximum | 0 feet/2 feet | |
Side setback, minimum | 0 feet | |
Rear setback, minimum | 10 feet | |
ACCESSORY STRUCTURE | ||
Side setback, minimum | 0 feet | |
Rear setback, minimum | 0 feet | |
Square footage of footprint per unit, maximum | 500 square feet | |
PARKING | ||
Parking setback, from front facade, minimum | 30 feet | |
Internal or underground parking must be wrapped by residential on street-facing facades (except for entries/exits) and may not be visible from a public street. | ||
*See § 325-45.2G(3), Siting exceptions. | ||
PRINCIPAL BUILDING | ||
Height (stories/feet), maximum | 8/85 | |
Height (stories/feet), minimum | 4/45 | |
ACCESSORY STRUCTURE | ||
Height (stories/feet), maximum | 2/20 | |
FLOOR HEIGHT | ||
Street-level (floor to floor), minimum | 12 feet | |
Upper-story (floor to floor), minimum | 10 feet | |
ROOF | ||
Flat roof | Required | |
Collegetown Zoning
Abbreviation | District | |
|---|---|---|
CR-1 | Collegetown Residential 1 | |
CR-2 | Collegetown Residential 2 | |
CR-3 | Collegetown Residential 3 | |
CR-4 | Collegetown Residential 4 | |
MU-1 | Mixed Use 1 | |
MU-2 | Mixed Use 2 |
Maximum and Minimum Height (in stories and feet) | |||||
|---|---|---|---|---|---|
District | Maximum (stories) | Minimum (stories) | Maximum (feet) | Minimum (feet) | |
CR-1 | 3* | 2 | 35 | 20 | |
CR-2 | 3* | 2 | 35 | 20 | |
CR-3 | 3* | 2 | 35 | 20 | |
CR-4 | 4 | 2 | 45 | 20 | |
MU-1 | 5 | 3 | 70 | 30 | |
MU-2 | 6 | 4 | 80 | 45 | |
NOTES: | ||
|---|---|---|
*Top story limitation. A habitable third story in CR-1, CR-2, and CR-3 Districts must be fully contained within a pitched roof. | ||
Purpose and intent. |
The Collegetown Residential 1-3 (CR-1, CR-2, CR-3) Districts contain predominantly residential structures occupied as single-family homes, as duplexes, or as multiple residences often rented by university students. The intent is to maintain the existing housing stock. Significant redevelopment within these districts is neither anticipated nor encouraged. |
Any new construction shall be similar in form and scale, and the zoning requirements of these districts are intended to protect the character of the established residential neighborhoods. Mandatory architectural elements, such as front porches and pitched roofs, ensure that new construction is in keeping with the existing built environment. All three districts have a maximum building height of three stories, provided that the third story is completely contained within the required pitched roof. In addition, buildings cannot exceed 35 feet in height. |
The Collegetown Residential 1-3 Districts accommodate single-family, two-family, and multifamily uses, depending on the district. Denser residential uses are permitted in those areas closer to central Collegetown. |
LOT SIZE | |||
Area, minimum | |||
1. | One-family detached dwelling | 4,000 square feet | |
2. | Other uses | 5,500 square feet | |
Width at street line, minimum | |||
1. | One-family detached dwelling | 45 feet | |
2. | Other uses | 50 feet | |
LOT COVERAGE | |||
Lot coverage by buildings, maximum | 30% | ||
Green space, minimum | 35% | ||
MINIMUM OFF-STREET PARKING | |||
1. | Residence | ||
a. Up to 3 bed or sleeping rooms per dwelling unit | 1 space | ||
b. 4 and 5 bed or sleeping rooms per dwelling unit | 2 spaces | ||
c. Each additional bed or sleeping room per dwelling unit | 1 space | ||
2. | Home occupation | 1 space | |
3. | Other uses | See § 325-20D(3)(b) | |
PRINCIPAL BUILDING | |||
Front setback, minimum | 10 feet | ||
Side setback, minimum | 5 feet | ||
Rear setback (whichever is less), minimum | 20 feet or 20% of lot depth | ||
Spacing between primary structures on same parcel, minimum | 20 feet | ||
ACCESSORY STRUCTURE | |||
Side setback, minimum | 5 feet | ||
Rear setback, minimum | 5 feet | ||
Square footage of footprint, maximum | 500 square feet | ||
PARKING LOCATION | |||
Garage setback from front facade, minimum | 20 feet | ||
Parking setback | at front facade | ||
PRINCIPAL BUILDING` | ||
Height (stories/feet), maximum | 3/35 | |
Height (stories/feet), minimum | 2/20 | |
Habitable space in the 3rd story must be fully contained within the pitched roof. See § 325-45.2B(11). | ||
ACCESSORY STRUCTURE | ||
Height (stories/feet), maximum | 2/20 | |
FLOOR HEIGHT (PRINCIPAL BUILDING) | ||
Street-level (floor to floor), minimum | 9 feet | |
2nd story (floor to floor), minimum | 9 feet | |
ROOF | ||
Pitched roof | Required | |
Shed roof not allowed as primary roof | ||
Pitch of principal gable, minimum/maximum | 6:12/12:12 | |
LOT SIZE | |||
Area, minimum | |||
1. | One-family or two-family dwelling | 4,000 square feet | |
2. | Other uses | 5,500 square feet | |
Width at street line, minimum | |||
1. | One-family or two-family dwelling | 45 feet | |
2. | Other uses | 50 feet | |
LOT COVERAGE | |||
Lot coverage by buildings, maximum | 35% | ||
Green space, minimum | 35% | ||
MINIMUM OFF-STREET PARKING | |||
1. | Residence | ||
a. Up to 3 bed or sleeping rooms per dwelling unit | 1 space | ||
b. 4 and 5 bed or sleeping rooms per dwelling unit | 2 spaces | ||
c. Each additional bed or sleeping room per dwelling unit | 1 space | ||
2. | Home occupation | 1 space | |
3. | Other uses | See § 325-20D(3)(b) | |
PRINCIPAL BUILDING | ||
Front setback, minimum | 10 feet | |
Side setback, minimum | 5 feet | |
Rear setback (whichever is less), minimum | 20 feet or 20% of lot depth | |
Spacing between primary structures on same parcel, minimum | 20 feet | |
ACCESSORY STRUCTURE | ||
Side setback, minimum | 3 feet | |
Rear setback, minimum | 3 feet | |
Square footage of footprint, maximum | 500 square feet | |
PARKING LOCATION | ||
Garage setback from front facade, minimum | 20 feet | |
Parking setback | at front facade | |
PRINCIPAL BUILDING | ||
Height (stories/feet), maximum | 3/35 | |
Height (stories/feet), minimum | 2/20 | |
Habitable space in the 3rd story must be fully contained within the pitched roof. See § 325-45.2B(11). | ||
ACCESSORY STRUCTURE | ||
Height (stories/feet), maximum | 2/20 | |
FLOOR HEIGHT (PRINCIPAL BUILDING) | ||
Street-level (floor to floor), minimum | 9 feet | |
2nd story (floor to floor), minimum | 9 feet | |
ROOF | ||
Pitched roof | Required | |
Shed roof not allowed as primary roof | ||
Pitch of principal gable, minimum/maximum | 6:12/12:12 | |
LOT SIZE | ||||
Area, minimum | ||||
1. | One-family or two-family dwelling | 3,000 square feet | ||
2. | Multiple dwelling and other uses | 3,500 square feet | ||
Width at street line, minimum | ||||
1. | One-family or two-family dwelling | 30 feet | ||
2. | Multiple dwelling and other uses | 40 feet | ||
LOT COVERAGE | ||||
Lot coverage by buildings, maximum | 40% | |||
Green space, minimum | 30% | |||
MINIMUM OFF-STREET PARKING | ||||
1. | Residence | |||
a. Up to 3 bed or sleeping rooms per dwelling unit | 1 space | |||
b. 4 and 5 bed or sleeping rooms per dwelling unit | 2 spaces | |||
c. Each additional bed or sleeping room per dwelling unit | 1 space | |||
2. | Home occupation | 1 space | ||
3. | Other uses | See § 325-20D(3)(b) | ||
PRINCIPAL BUILDING | ||
Front setback, minimum | 10 feet | |
Side setback, minimum | 5 feet | |
Rear setback (whichever is less), minimum | 20 feet or 20% of lot depth | |
Spacing between primary structures on same parcel, minimum | 10 feet | |
ACCESSORY STRUCTURE | ||
Side setback, minimum | 3 feet | |
Rear setback, minimum | 3 feet | |
Square footage of footprint per unit, maximum | 500 square feet | |
PARKING LOCATION | ||
Garage setback from front facade, minimum | 20 feet | |
Parking setback | at front facade | |
PRINCIPAL BUILDING | ||
Height (stories/feet), maximum | 3/35 | |
Height (stories/feet), minimum | 2/20 | |
Habitable space in the 3rd story must be fully contained within the pitched roof. See § 325-45.2B(11). | ||
ACCESSORY STRUCTURE | ||
Height (stories/feet), maximum | 2/20 | |
FLOOR HEIGHT (PRINCIPAL BUILDING) | ||
Street-level (floor to floor), minimum | 9 feet | |
2nd story (floor to floor), minimum | 9 feet | |
ROOF | ||
Pitched roof | Required | |
Shed roof not allowed as primary roof | ||
Pitch of principal gable, minimum/maximum | 6:12/12:12 | |
Purpose and intent. |
|---|
The Collegetown Residential 4 District primarily contains multifamily dwelling units, and while single-family and two-family residential uses are permitted, it is expected that multifamily residential will remain the predominant use. The intent is this will be a medium-density residential district, consistent with the vision outlined in the 2009 Collegetown Urban Plan and Conceptual Design Guidelines to concentrate additional development in the central areas of Collegetown. |
This district serves as an essential bridge, both in density and built form, between the Collegetown Residential 1-3 and Mixed Use Districts. Redevelopment is encouraged, but it is essential that new construction meet the district requirements to ensure a consistent transition between the higher-density and lower-density zoning districts. District regulations permit buildings of up to four stories and 45 feet in height; a building must meet both requirements. Maximum lot coverage by buildings is greater than in the Collegetown Residential Districts 1-3 but not as high as allowed in the Mixed Use Districts. In terms of form, the district requirements provide property owners with choices between architectural features intended to create buildings compatible with those in adjacent zoning districts. |
LOT SIZE | |||
Area, minimum | |||
1. | One-family or two-family dwelling | 3,000 square feet | |
2. | Multiple dwelling and other uses | 3,500 square feet | |
Width at street line, minimum | |||
1. | One-family or two-family dwelling | 30 feet | |
2. | Multiple dwelling and other uses | 40 feet | |
LOT COVERAGE | |||
Lot coverage by buildings, maximum | 50% | ||
Green space, minimum | 25% | ||
MINIMUM OFF-STREET PARKING | |||
Buildings that fully comply with the New York State | |||
Building Code or Residential Code for new construction: | |||
None, provided a transportation demand management plan is accepted by the Planning and Development Board during site plan review | |||
All other structures: | |||
1. | Residence | ||
a. Up to 3 bed or sleeping rooms per dwelling unit | 1 space | ||
b. 4 and 5 bed or sleeping rooms per dwelling unit | 2 spaces | ||
c. Each additional bed or sleeping room per dwelling unit | 1 space | ||
2. | Home occupation | 1 space | |
3. | Other uses | See § 325-20D(3)(b) | |
PRINCIPAL BUILDING | |||
Front setback, minimum | 10 feet | ||
Side setback, minimum | |||
1. | Row house | 0 feet | |
2. | All other structures | 5 feet | |
Rear setback (whichever is less), minimum | 10 feet or 20% of lot depth | ||
Spacing between primary structures on same parcel, minimum | 5 feet | ||
ACCESSORY STRUCTURE | |||
Side setback, minimum | 3 feet | ||
Rear setback, minimum | 3 feet | ||
Square footage of footprint per unit, maximum | 500 square feet | ||
PARKING LOCATION | |||
Garage setback from front facade, minimum | 20 feet | ||
Parking setback | at front facade | ||
Internal or underground parking must be wrapped by residential on street-facing facades (except for entries/exits) and may not be visible from a public street. | |||
PRINCIPAL BUILDING | ||
Height (stories/feet), maximum | 4/45 | |
Height (stories/feet), minimum | 2/20 | |
ACCESSORY STRUCTURE | ||
Height (stories/feet), maximum | 2/20 | |
FLOOR HEIGHT (PRINCIPAL BUILDING) | ||
Street-level (floor to floor), minimum | 9 feet | |
Upper-story (floor to floor), minimum | 9 feet | |
ROOF | ||
Pitched or flat roof | Allowed | |
STREET FACADE | |||
Building length, primary street, maximum | |||
1. | Row house | 100 feet | |
2. | All other structures | 45 feet | |
Length of blank wall, maximum | 8 feet | ||
DOORS AND ENTRIES | |||
Functioning entry on the street-facing facade, minimum | 1 | ||
For corner lots, one functioning entry is required on the primary street-facing facade. | |||
PORCH, STOOP OR RECESSED ENTRY | |||
Front porch, stoop or recessed entry required for each functional entry | |||
Purpose and intent. |
|---|
The Mixed Use Districts accommodate retail, office, service, hotel, and residential uses, and in most cases, multiple uses will be combined within the same building. The purpose is to create a dynamic urban environment in which uses reinforce each other and promote an attractive, walkable neighborhood. |
Located in central Collegetown, the Mixed Use Districts allow the highest density within the Collegetown Area Form Districts. Redevelopment is anticipated and encouraged (with the exception of designated local landmarks), and the intent is to concentrate the majority of additional development within these districts. |
The Mixed Use District regulations have been designed to encourage exceptional urban design and high-quality construction. The Mixed Use 1 District permits buildings of up to five stories and 70 feet in height while the Mixed Use 2 District allows buildings of up to six stories and 80 feet in height. A building cannot exceed either requirement. While it may be feasible to design a building with a greater number of stories within the maximum allowed height, in feet, the intent of the district regulations is to meet both requirements. The additional building height, in feet, has been allowed for the purpose of providing adequate space for mechanicals and accommodating high-quality design features and finishes. |
An objective of both Mixed Use Districts is to create an urban form that gives priority to pedestrians and encourages year-round commercial activity at the street level. Required form elements, such as a maximum distance between entries and a maximum length of blank wall, activate the street-level of buildings to engage pedestrians through this highly traveled section of Collegetown. In addition, front setback requirements have been incorporated to ensure adequate space to provide wider sidewalks and a safer pedestrian environment. A required ten-foot chamfer or additional setback at corner lots within the Mixed Use 2 District will allow greater visibility and natural light at busy intersections. |
LOT SIZE | |||
Area, minimum | |||
1. | One-family or two-family dwelling | 3,000 square feet | |
2. | Multiple dwelling and other uses | 3,500 square feet | |
Width at street line, minimum | |||
1. | One-family or two-family dwelling | 30 feet | |
2. | Multiple dwelling and other uses | 40 feet | |
LOT COVERAGE | |||
Lot coverage by buildings, maximum | 70% | ||
Green space, minimum | 10% | ||
MINIMUM OFF-STREET PARKING | |||
None | |||
PRINCIPAL BUILDING | |||
Front setback, minimum | 5 feet | ||
Side setback, minimum | 5 feet | ||
1. | Row house | 0 feet | |
2. | All other structures | 5 feet | |
Rear setback, minimum | 10 feet | ||
Spacing between primary structures on same parcel, minimum | 5 feet | ||
ACCESSORY STRUCTURE | |||
Side setback, minimum | 0 feet | ||
Rear setback, minimum | 0 feet | ||
Square footage of footprint per unit, maximum | 500 square feet | ||
PARKING LOCATION | |||
Parking setback, from front facade, minimum | 30 feet | ||
Internal or underground parking must be wrapped by residential on street-facing facades (except for entries/exits) and may not be visible from a public street. | |||
PRINCIPAL BUILDING | |||
Height (stories/feet), maximum | 7/75 | ||
Height (stories/feet), minimum | 3/30 | ||
ACCESSORY STRUCTURE | |||
Height (stories/feet), maximum | 2/20 | ||
FLOOR HEIGHT (PRINCIPAL BUILDING) | |||
Street-level (floor to floor), minimum | |||
1. | Residential | 10 feet | |
2. | Commercial | 12 feet | |
Upper-story (floor to floor), minimum | 10 feet | ||
ROOF | |||
Pitched or flat roof | Allowed | ||
STREET FACADE | |||
Building length, primary street, length, maximum | |||
1. | Row house | 150 feet | |
2. | All other structures | 75 feet | |
Length of blank wall, maximum | 12 feet | ||
DOORS AND ENTRIES | |||
Distance between functioning street-facing entries, maximum | 35 feet | ||
Commercial entries must be functioning and usable during business hours. | |||
RECESSED ENTRY | |||
Recessed entry required for each functional entry | |||
LOT SIZE | ||
Area, minimum | 2,500 square feet | |
Width at street line, minimum | 25 feet | |
LOT COVERAGE | ||
Lot coverage by buildings, maximum | 100%, except as required for rear yard | |
Green space, minimum | 0% | |
MINIMUM OFF-STREET PARKING | ||
None | ||
PRINCIPAL BUILDING* | ||
Front setback, minimum/maximum | 0 feet/2 feet | |
Side setback, minimum | 0 feet | |
Rear setback, minimum | 10 feet | |
ACCESSORY STRUCTURE | ||
Side setback, minimum | 0 feet | |
Rear setback, minimum | 0 feet | |
Square footage of footprint per unit, maximum | 500 square feet | |
PARKING | ||
Parking setback, from front facade, minimum | 30 feet | |
Internal or underground parking must be wrapped by residential on street-facing facades (except for entries/exits) and may not be visible from a public street. | ||
*See § 325-45.2G(3), Siting exceptions. | ||
PRINCIPAL BUILDING | ||
Height (stories/feet), maximum | 8/85 | |
Height (stories/feet), minimum | 4/45 | |
ACCESSORY STRUCTURE | ||
Height (stories/feet), maximum | 2/20 | |
FLOOR HEIGHT | ||
Street-level (floor to floor), minimum | 12 feet | |
Upper-story (floor to floor), minimum | 10 feet | |
ROOF | ||
Flat roof | Required | |