Commercial Districts


Development Standards | Central Business District |
Minimum Lot Size (Sq. Ft.) | None |
Minimum Frontage | None |
Minimum Front Setback | None, except when the proposed structure is located between two existing structures on adjacent lots, then utilize average front setback as defined in Chapter 1161
. |
Maximum Front Setback | Ten (10), except however, up to fifty (50) percent of a building's façade may be setback more than the required maximum front setback, if the required public gathering space is located in front of this portion of the building. In such cases, a decorative wall or fence shall be installed in front of the public gathering space to help enhance the overall streetscape. |
Minimum Side Setback | None |
Minimum Rear Setback | None |
Residential Density | 30 units/acre |
Parking in front of Principal Building | Prohibited |
Maximum Height | Seventy-five (75), except however, mechanical equipment and/or ventilation systems may extend up to ten feet above the height of the building. Said mechanical equipment/ventilation systems must be screened from view by parapet walls, mansard roofs or other screening material approved by the City Planner or designee, provided said material has one hundred (100) percent opacity year-round. |
Minimum amount of private gathering spaces for residential units (Patio/Balcony) | 50 sq. ft. per unit |
Public Open/Gathering Space (may include plazas, public patios, outdoor dining areas, courtyards, or common rooftop garden areas) | 5% of gross square footage of all buildings |


Applicable | Section Reference | Notes | |
Accessory Structures | Y | Section | Detached Accessory Structures may encroach a side or rear setback but shall be no closer than five (5) feet from the side or rear lot line. Accessory structures shall also comply with all other requirements in Section 1147.02.
|
Fences | Y | Section | Fences and walls may be placed in a required minimum setback provided they comply with Section 1147.05
. |
Landscaping/ Buffering | Y | Chapter | Plant material and berms may be placed between the minimum and maximum setbacks provided they do not constitute a nuisance as provided in the Lancaster Codified Ordinances. |
Parking | Y | Chapter | Parking must be provided in accordance with Chapter 1143
. Parking is prohibited in front of the principal structure. Parking may encroach a side or rear setback provided the parking is no closer than five feet from said lot line. |
Signs | Y | Chapter | Signs, provided they comply with Section Chapter 1145
. Blade signs may encroach the public right-of-way when approved by the City Engineer. |


Development Standards | Commercial Neighborhood |
Minimum Lot Size (Sq. Ft.) | None |
Minimum Frontage (Feet) | None |
Minimum Front Setback (Feet) | 10 |
Maximum Front Setback (Feet) | 60 |
Minimum Side Setback (Feet) | 10, except however, when a side or rear lot line abuts an existing residential use or District that permits one (1) unit dwellings, then a buffer shall be provided in accordance with Section 1141.10
. |
Minimum Rear Setback (Feet) | Twenty (20), except however, when a side or rear lot line abuts an existing residential use or District that permits one-unit dwellings, then a buffer shall be provided in accordance with Section 1141.10.
|
Maximum Height (Feet) | Thirty-five (35), except however, mechanical equipment and/or ventilation systems may extend up to ten feet above the height of the building. Said mechanical equipment/ventilation systems must be screened from view by parapet walls, mansard roofs or other screening material approved by the City Planner or designee, provided said material has one hundred (100) percent opacity year-round. |
Maximum Lot Coverage (Percent) | 80 |


Applicable | Section Reference | Notes | |
Accessory Structures | Y | Section | Detached Accessory Structures may encroach a side or rear setback but shall be no closer than five (5) feet from the side or rear lot line. Accessory structures shall also comply with all other requirements in Section 1147.02.
|
Fences | Y | Section | Fences and walls may be placed in a required minimum setback provided they comply with Section 1147.05.
|
Landscaping/ Buffering | Y | Chapter | Plant material and berms may be placed in the required setbacks provided they do not constitute a nuisance as provided in the Lancaster Codified Ordinances. |
Parking | Y | Chapter | Limited - Parking is permitted in front of a principal building, but it is encouraged to be placed to the side or rear of the principal building. Parking may encroach a front, side or rear setback provided the parking is no closer than five feet from said lot line. |
Signs | Y | Chapter |


Development Standards | Commercial - General |
Minimum Lot Size (Sq. Ft.) | None |
Minimum Frontage (Feet) | 50 |
Minimum Front Setback (Feet) | 50 (Arterial and Collector) 25 (all other roads) |
Maximum Front Setback (Feet) | N/A |
Minimum Side Setback (Feet) | Twenty (20), except however, when a side or rear lot line abuts an existing residential use or District that permits single unit dwellings, then a buffer shall be provided in accordance with Section 1141.10.
|
Minimum Rear Setback (Feet) | Twenty-five (25), except however, when a side or rear lot line abuts an existing residential use or District that permits single unit dwellings, then a buffer shall be provided in accordance with Section 1141.10
. |
Maximum Height (Feet) | Sixty (60), except however, mechanical equipment and/or ventilation systems may extend up to ten feet above the height of the building. Said mechanical equipment/ventilation systems must be screened from view by parapet walls, mansard roofs or other screening material approved by the City Planner or designee, provided said material has one hundred (100) percent opacity year-round. |
Maximum Lot Coverage (Percent) | 80 |


Applicable | Section Reference | Notes | |
Accessory Structures | Y | Section | Detached Accessory Structures may encroach a side or rear setback but shall be no closer than five (5) feet from the side or rear lot line. Accessory structures shall also comply with all other requirements in Section 1147.02.
|
Fences | Y | Section | Fences and walls may be placed in a required minimum setback provided they comply with Section 1147.05.
|
Landscaping/ Buffering | Y | Chapter | Plant material and berms may be placed in the required setbacks provided they do not constitute a nuisance as provided in the Lancaster Codified Ordinances. |
Parking | Y | Chapter | Limited - Parking is permitted in front of a principal building, but it is encouraged to be placed to the side or rear of the principal building. Parking may encroach a front, side or rear setback provided the parking is no closer than five feet from said lot line. |
Signs | Y | Chapter |
Commercial Districts


Development Standards | Central Business District |
Minimum Lot Size (Sq. Ft.) | None |
Minimum Frontage | None |
Minimum Front Setback | None, except when the proposed structure is located between two existing structures on adjacent lots, then utilize average front setback as defined in Chapter 1161
. |
Maximum Front Setback | Ten (10), except however, up to fifty (50) percent of a building's façade may be setback more than the required maximum front setback, if the required public gathering space is located in front of this portion of the building. In such cases, a decorative wall or fence shall be installed in front of the public gathering space to help enhance the overall streetscape. |
Minimum Side Setback | None |
Minimum Rear Setback | None |
Residential Density | 30 units/acre |
Parking in front of Principal Building | Prohibited |
Maximum Height | Seventy-five (75), except however, mechanical equipment and/or ventilation systems may extend up to ten feet above the height of the building. Said mechanical equipment/ventilation systems must be screened from view by parapet walls, mansard roofs or other screening material approved by the City Planner or designee, provided said material has one hundred (100) percent opacity year-round. |
Minimum amount of private gathering spaces for residential units (Patio/Balcony) | 50 sq. ft. per unit |
Public Open/Gathering Space (may include plazas, public patios, outdoor dining areas, courtyards, or common rooftop garden areas) | 5% of gross square footage of all buildings |


Applicable | Section Reference | Notes | |
Accessory Structures | Y | Section | Detached Accessory Structures may encroach a side or rear setback but shall be no closer than five (5) feet from the side or rear lot line. Accessory structures shall also comply with all other requirements in Section 1147.02.
|
Fences | Y | Section | Fences and walls may be placed in a required minimum setback provided they comply with Section 1147.05
. |
Landscaping/ Buffering | Y | Chapter | Plant material and berms may be placed between the minimum and maximum setbacks provided they do not constitute a nuisance as provided in the Lancaster Codified Ordinances. |
Parking | Y | Chapter | Parking must be provided in accordance with Chapter 1143
. Parking is prohibited in front of the principal structure. Parking may encroach a side or rear setback provided the parking is no closer than five feet from said lot line. |
Signs | Y | Chapter | Signs, provided they comply with Section Chapter 1145
. Blade signs may encroach the public right-of-way when approved by the City Engineer. |


Development Standards | Commercial Neighborhood |
Minimum Lot Size (Sq. Ft.) | None |
Minimum Frontage (Feet) | None |
Minimum Front Setback (Feet) | 10 |
Maximum Front Setback (Feet) | 60 |
Minimum Side Setback (Feet) | 10, except however, when a side or rear lot line abuts an existing residential use or District that permits one (1) unit dwellings, then a buffer shall be provided in accordance with Section 1141.10
. |
Minimum Rear Setback (Feet) | Twenty (20), except however, when a side or rear lot line abuts an existing residential use or District that permits one-unit dwellings, then a buffer shall be provided in accordance with Section 1141.10.
|
Maximum Height (Feet) | Thirty-five (35), except however, mechanical equipment and/or ventilation systems may extend up to ten feet above the height of the building. Said mechanical equipment/ventilation systems must be screened from view by parapet walls, mansard roofs or other screening material approved by the City Planner or designee, provided said material has one hundred (100) percent opacity year-round. |
Maximum Lot Coverage (Percent) | 80 |


Applicable | Section Reference | Notes | |
Accessory Structures | Y | Section | Detached Accessory Structures may encroach a side or rear setback but shall be no closer than five (5) feet from the side or rear lot line. Accessory structures shall also comply with all other requirements in Section 1147.02.
|
Fences | Y | Section | Fences and walls may be placed in a required minimum setback provided they comply with Section 1147.05.
|
Landscaping/ Buffering | Y | Chapter | Plant material and berms may be placed in the required setbacks provided they do not constitute a nuisance as provided in the Lancaster Codified Ordinances. |
Parking | Y | Chapter | Limited - Parking is permitted in front of a principal building, but it is encouraged to be placed to the side or rear of the principal building. Parking may encroach a front, side or rear setback provided the parking is no closer than five feet from said lot line. |
Signs | Y | Chapter |


Development Standards | Commercial - General |
Minimum Lot Size (Sq. Ft.) | None |
Minimum Frontage (Feet) | 50 |
Minimum Front Setback (Feet) | 50 (Arterial and Collector) 25 (all other roads) |
Maximum Front Setback (Feet) | N/A |
Minimum Side Setback (Feet) | Twenty (20), except however, when a side or rear lot line abuts an existing residential use or District that permits single unit dwellings, then a buffer shall be provided in accordance with Section 1141.10.
|
Minimum Rear Setback (Feet) | Twenty-five (25), except however, when a side or rear lot line abuts an existing residential use or District that permits single unit dwellings, then a buffer shall be provided in accordance with Section 1141.10
. |
Maximum Height (Feet) | Sixty (60), except however, mechanical equipment and/or ventilation systems may extend up to ten feet above the height of the building. Said mechanical equipment/ventilation systems must be screened from view by parapet walls, mansard roofs or other screening material approved by the City Planner or designee, provided said material has one hundred (100) percent opacity year-round. |
Maximum Lot Coverage (Percent) | 80 |


Applicable | Section Reference | Notes | |
Accessory Structures | Y | Section | Detached Accessory Structures may encroach a side or rear setback but shall be no closer than five (5) feet from the side or rear lot line. Accessory structures shall also comply with all other requirements in Section 1147.02.
|
Fences | Y | Section | Fences and walls may be placed in a required minimum setback provided they comply with Section 1147.05.
|
Landscaping/ Buffering | Y | Chapter | Plant material and berms may be placed in the required setbacks provided they do not constitute a nuisance as provided in the Lancaster Codified Ordinances. |
Parking | Y | Chapter | Limited - Parking is permitted in front of a principal building, but it is encouraged to be placed to the side or rear of the principal building. Parking may encroach a front, side or rear setback provided the parking is no closer than five feet from said lot line. |
Signs | Y | Chapter |