16 PARKING AND CIRCULATION
Table 13.16.040-1: Bicycle Parking Spaces Required | ||
|---|---|---|
Use | Number of Bicycle Parking Spaces | Classification |
Commercial, industrial, office, retail, service | 15% of vehicle parking requirement prior to any reductions applied Minimum of 2 spaces1 | Minimum 20% Class 1 80% Class 2 |
Multifamily residential (apartments and condominiums) | 1 space per unit plus 20% guest parking | 100% Class 1 in garages or secure accessible indoor areas count 1 space per 4 units Class 2 |
Townhomes | 20% guest parking | 100% Class 2 |
Public facility | 35% of vehicle parking, prior to any reductions applied | Minimum 10% Class 1 90% Class 2 |
Schools | 1 space per 3 students prior to any reductions applied | 100% Class 2 secured, covered |
Visitor accommodations | 1 space per 5 rooms/beds prior to any reductions applied | Minimum 10% Class 1 90% Class 2 |
1. See subsection (D) of this section for exceptions. |
Figure 13.16.040-1: Design Standards for Off Street Bicycle Parking ![]() |
Figure 13.16.040-2: Access and Design Standards for Off Street Bicycle Parking ![]() |
Figure 13.16.040-3: Bicycle Rack Parking Design Standards in Public Right-of-Way ![]() |
Table 13.16.041-1: Shower Facility Requirements | ||
|---|---|---|
Use | Gross Floor Area of New Construction (Square Feet) | Number of Showers |
Industrial, manufacturing, and medical, general business office or financial service | 0—12,499 | No requirement |
12,500—29,999 | 1 | |
30,000—49,999 | 2 | |
50,000 and up | 4 | |
Retail, eating and drinking and personal service | 0—24,999 | No requirement |
25,000—99,999 | 1 | |
100,000 and up | 2 | |
Table 13.16.050-1: Off-Street Vehicle Parking Spaces Required | ||
|---|---|---|
Use | Requirement | |
Commercial & Industrial1 | ||
Dine-in restaurants2, bars and coffee shops with 13 or more seats | 1 per 100 gross square feet (GSF) | |
Retail, commercial services, shopping centers, convenience stores, supermarkets, fast food and cafes with 12 seats or less | 1 per 300 GSF | |
Physical fitness facilities: athletic clubs, gymnasiums, other physical recreation facilities. | 1 per 150 GSF | |
Offices and laboratories | 1 per 300 GSF or 1 per 350 GSF if in transit priority area3 | |
Medical offices | 1 per 225 GSF | |
Visitor accommodations (Type A and B) | 1 per room or unit | |
Manufacturing and other industrial uses except warehousing and self storage | 1 per 600 GSF and 2 minimum | |
Warehousing | 1 per 1,000 GSF | |
Self Storage | 1 per 10,000 GSF plus 1 per 500 GSF of accessory office space | |
Public and Quasi-Public Facilities | ||
Hospital | 0.5 for each bed plus 1 for each employee on peak shift | |
Emergency shelter | 1 space per 7 beds plus 1 space for each awake overnight staff person | |
Libraries, museums, art galleries, churches, night clubs, entertainment venues, assembly halls and other places of public assembly | 1 for each 3 seats or for each 3 persons of design occupancy load if no seats | |
Elementary school and junior high school | 2.25 per classroom or teaching station | |
High school | 1 per employee plus 1 per 6 students | |
College, university, professional or trade school | 1 per employee plus 1 per 3 students | |
Care Facilities | ||
Day care centers (not including family care homes) or residential care | 1 per every 5 persons for whom care is provided, plus 1 for the resident owner or manager | |
Nursing homes and assisted living facilities | 1 per 3 beds/rooms plus 1 per employee on peak shift | |
Residential 4,7 | ||
Detached single-family, duplexes and mobile homes including employee housing | 1 bedroom | 1 |
2—3 bedrooms | 2 | |
4 bedrooms or more | 3 | |
Attached single-family (townhomes) | 1 bedroom | 1 per unit plus 20% guest parking |
2+ bedrooms | 2 per unit plus 20% guest parking | |
Permanent room housing and single room occupancy | 1 space per separately leasable room | |
Senior housing and transitional housing5 | 0.5 spaces per unit minimum 1 space per unit maximum | |
Multifamily6 | Units less than or equal to 750 GSF | 1 per unit plus 20% guest parking (30% in LODA/SALSDA/DASDA) or 1 per unit if in transit priority area3 |
Units greater than 750 GSF | 2 per unit plus 20% guest parking (30% in LODA/SALSDA/DASDA) or 1.5 per unit if in transit priority area3 | |
Accessory dwelling units | Up to 1 per unit: See SCCC § 13.10.681 for details and exceptions | |
1. Auto storage areas associated with commercial services do not count as parking. |
2. Includes indoor and outdoor dining establishments. |
3. Transit priority area (TPA) parking reductions are optional and are not allowed for in the LODA/SALSDA/DASDA. TPA is defined by Public Resources Code Section 21064. |
4. Residential projects that qualify for a density bonus pursuant to Chapter 17.12 SCCC may use the alternative (state) parking standards provided in that chapter. |
5. Transitional housing may be located in any type of residential structure (single-family, condominium, SRO/PRH, multifamily, etc.) and state law requires it be treated as the same as any other residential use in the same zone. Apply the parking standards for the structure type in which the transitional housing project is proposed, per Table 13.16.050-1, unless the project qualifies for parking reductions based on state law, depending on project type, occupant type, etc. |
6. Manager's units are required to have the same parking ratio as other units. |
7. Guest parking shall be provided as common parking accessible to all parcel occupants and visitors. |
Table 13.16.050-2: Accessible Parking Spaces Required | |
|---|---|
Total Off-Street Spaces Required | Maximum Number of Accessible Spaces Required |
1—25 | 1 |
26—50 | 2 |
51—75 | 3 |
76—100 | 4 |
101—150 | 5 |
151—200 | 6 |
201—300 | 7 |
301—400 | 8 |
401—500 | 9 |
501—1,000 | Two percent of the total parking |
1,001 and over | 20 plus 1 for each 100, or fraction thereof over 1,001 |
Table 13.16.050-3: Compact Parking Spaces Required | |
|---|---|
Total Spaces Required | Allowable Percentage of Compact Car Spaces |
0—5 | 0 |
6—50 | 10% |
51—80 | 30% |
81 or more | 40% |
Figure 13.16.060-1: Parking Lot Landscaping Strip Options ![]() |
Figure 13.16.060-2: Parking Lot Tree Well Options ![]() |
Figure 13.16.060-3: Parking Space Design 45 Degree ![]() |
Figure 3.16.060-4: Parking Space Design 60 Degree ![]() |
Figure 3.16.060-5: Parking Space Design 90 Degree* ![]() |
*For lots with cars on one side of aisle only, the aisle width shall be 22 feet for two-way circulation and 18 feet for one-way circulation. |
Table 13.16.060-1: Minimum Parking Lot Dimensions | ||
|---|---|---|
Parking Angle | Cars on One Side of Aisle1 | Cars on Both Sides of Aisle |
90°1 | 40' two-way/36' one-way | 60' two-way/58' one-way |
60° | 36' | 56' |
45° | 33' | 52' |
1. For lots with cars on one side of aisle only, the aisle width shall be 22 feet for two-way circulation and 18 feet for one-way circulation. |
Table 13.16.091-1: Drive-Through Stacking Requirements | |
|---|---|
Use | Minimum Stacking Room |
Car wash | 4 reservoir spaces per pull-through rack. 1 reservoir space per self-service manual wash bay. |
Drive-through bank | 3 reservoir spaces for 1 teller drive-up. 2 reservoir spaces each for facilities with 2 or more teller drive-ups. |
Drive-through pharmacy | 2 reservoir spaces per window. |
Automobile service station | 1 reservoir space shall be located on each end of the pump aisle. |