Development Standards
Table 50-1: Sound Levels | |||
|---|---|---|---|
District | Level Limit db(A) | 11:00 p.m. to 7:00 a.m. Level Limit db(A) | |
A. Residential | 60 | 55 | |
B. Commercial | 70 | 65 | |
C. Industrial | 80 | 75 | |
Table 51-1: Minimum Aisle Widths | |||
|---|---|---|---|
Angle of Parking | Minimum Aisle Width | ||
Two-way Traffic (feet) | One-way Traffic (feet) | ||
1. Ninety-degree parking | 24 | 22 | |
2. Sixty-degree parking | 23 | 18 | |
3. Forty-five-degree parking | 21 | 13 | |
4. Parallel parking | 19 | 13 | |
Table 51-2: Minimum Size of Parking Spaces | |||
|---|---|---|---|
Angle of Parking | Minimum Width (feet) | Minimum Length (feet) | |
1. Ninety-degree parking | 9 | 18 | |
2. Sixty-degree parking | 9 | 18 | |
3. Forty-five-degree parking | 9 | 18 | |
4. Parallel parking | 8 | 22 | |
Table 51-3: Access Driveway Dimensions by Use | |||
|---|---|---|---|
Use | Minimum Width (feet) | Maximum Width (feet) | |
1. Single-family | 10 | 20 | |
2. Multifamily | 16 (combined drive) | 20 | |
3. All other uses | 12 (one-way) 20 (two-way) | 30 | |
Table 51-4: Minimum Parking Space Requirements by Use | ||
|---|---|---|
Use Classification | Minimum Parking Requirement | |
A. Residential | ||
Single-family dwelling | 2 per dwelling unit | |
Two-family dwelling | 2 per dwelling unit | |
Multifamily dwelling, studio to 1-bedroom | 1 per dwelling unit | |
Multifamily dwelling, 2-3 bedroom units | 2 per dwelling unit | |
Senior housing | 1 per dwelling unit | |
Boarding houses | 2 spaces + 0.5 per rooming unit | |
B. Government/Cultural/Educational | ||
Schools, elementary and intermediate | 1 per employee + 2 per classroom | |
Schools, secondary | 1 per 10 students + 1 per employee + 2 per classroom | |
Schools, occupational/skill training | 1 per instructor + 1 per 3 students | |
Religious institution | 1 per 3.5 seats | |
Community center | 6 per 1,000 square feet | |
Library | 2 per 1,000 square feet | |
Auditorium | 1 per 3.5 seats | |
Private club | 8 per 1,000 square feet | |
Recreational: | ||
Bowling alley | 2 per lane | |
Skating rink | 1 per 5 persons (based on capacity) | |
Swimming pool | 1 per 4 persons (based on capacity) | |
Tennis club | 3 per court | |
Day-care or nursery | 1 per 6 enrolled + 1 per employee | |
Hospital | 1 per bed + 1.5 per employee (during maximum shift) | |
Medical clinic, medical office | 5 per 1,000 square feet | |
Nursing home | 1 per 2 beds + 1.5 per employee (during maximum shift) | |
C. Commercial/Retail | ||
General retail | 3 per 1,000 square feet | |
Food store | 5 per 1,000 square feet | |
Convenience store | 5 per 1,000 square feet | |
Home occupations | Maximum of 2 spaces, in addition to residential requirement | |
D. Service | ||
Bank | 2 per 1,000 square feet | |
Drinking establishment/tavern/nightclub | 5 per 1,000 square feet | |
Bed-and-breakfast | 2 spaces + 1 per guest bedroom | |
Barbershop/beauty salon | 1.5 per chair | |
Dry cleaning/laundromat | 2 per 1,000 square feet | |
Hotel/motel | 1 per room + 1 for every employee on a single shift | |
Funeral homes | 10 per 1,000 square feet | |
Office, professional or business | 3 per 1,000 square feet | |
Restaurant, carry-out | 2 per 1,000 square feet | |
Restaurant, drive-through | 1 per employee + 4 per 1,000 square feet | |
Restaurant, sit-down | 5 per 1,000 square feet | |
E. Vehicle-Related | ||
Vehicle repair/service or gas station | 2 per bay | |
Vehicle sales | 2 per employee | |
Vehicle rental | 1 per 1,000 square feet floor area | |
Car wash | 1 per employee | |
F. Industrial/Manufacturing | ||
All uses | 1 per employee during maximum shift | |
Table 51-5: Minimum Space Dimensions | ||||
|---|---|---|---|---|
Class of Loading Space | Minimum Width (feet) | Minimum Length (feet) | Minimum Height (feet) | |
1. A (for semi-truck vehicles) | 14 | 50 | 15 | |
2. B (for other vehicles) | 12 | 25 | 14 | |
Table 51-6: Number of Loading Spaces Required | |||
|---|---|---|---|
Gross Floor Area (square feet) | Number | Class | |
1. Less than 4,000 | 0 | — | |
2. 4,000 to 15,000 | 1 | B | |
3. 15,000 to 30,000 | 1 | A | |
4. 30,000 or greater | 1 each | A and B | |
5. Each additional 50,000; or fraction thereof | 1 | A | |
Table 52-1 Table of Sign Regulations | ||||
|---|---|---|---|---|
R-1 | NC | VC | I | |
Zoning District | Village Residential | Neighborhood Commercial | Village Center | Industrial |
Freestanding Signs (Monument) | Any sign not affixed to a building constructed at grade level with continuous foundation. | |||
|---|---|---|---|---|
R-1 | NC | VC | I | |
Permitted in Zone | NP | P | NP | P |
Maximum number permitted | — | 1 per lot | — | 1 per lot |
Maximum area (square feet) | — | 6 | — | 50 |
Maximum height (feet) | — | 5 | — | 6 |
Setback (feet) | — | 10 | — | 10 |
Internal lighting | — | NP | — | P |
External lighting | — | P | — | P |
Wall Signs | Any sign fastened to a building or structure in such a manner that the wall becomes the supporting structure for or forms the background surface of the sign. The sign will not project more than 18 inches from the building or structure. | |||
|---|---|---|---|---|
R-1 | NC | VC | I | |
Permitted in Zone | P | P | P | P |
Maximum number permitted | 1 per structure | 1 per structure | 1 per use | 1 per use |
Size allocation NOTE: *whichever is less | 2 square feet | 20% or 12 square feet* | 20% or 2 square feet per linear foot of frontage* | 100 square feet |
Maximum height (feet) | — | — | 4 | — |
Internal lighting | NP | NP | P | P |
External lighting | P | P | P | P |
Projecting Signs | A sign wholly or partly dependent upon a building for support and which projects more than 18 inches from the building. | |||
|---|---|---|---|---|
R-1 | NC | VC | I | |
Permitted in Zone | NP | P | P | P |
Maximum number permitted | — | 1 per structure | 1 per use | 1 per use |
Maximum area (square feet) | — | 6 | 20 | 20 |
Vertical clearance (feet) | — | 8 | 8 | 8 |
Internal lighting | — | NP | NP | P |
External lighting | — | P | P | P |
Maximum projection (feet) | — | 4 | 4 | 4 |
Suspended Signs | A sign attached to and supported by the underside of a horizontal plane. | |||
|---|---|---|---|---|
R-1 | NC | VC | I | |
Permitted in Zone | NP | P | P | P |
Maximum number permitted | — | 1 per structure | 1 per use | 1 per use |
Maximum area (square feet) | — | 3.5 | 3.5 | 3.5 |
Vertical clearance (feet) | — | 8 | 8 | 8 |
Internal lighting | — | NP | NP | P |
External lighting | — | P | P | P |
Awning and Canopy Signs | Any sign that is a part of or attached to an awning, canopy, or other fabric, plastic, or structural protective cover over a door, entrance, window, or outdoor service area. | |||
|---|---|---|---|---|
R-1 | NC | VC | I | |
Permitted in Zone | P | P | P | P |
Maximum number permitted | 1 per structure | 1 per structure | 1 per structure | 1 per structure |
Internal lighting | NP | NP | NP | NP |
External lighting | NP | NP | NP | NP |
NOTE: Awning signs may only be placed in the area encompassed by the bottommost six inches of the awning edge that runs parallel to the ground. | ||||
Window and Door Signs | A non-electric sign applied or attached to the interior of a window or door or within three feet of the interior which can be seen from the exterior. | |||
|---|---|---|---|---|
R-1 | NC | VC | I | |
Permitted in Zone | NP | P | P | P |
Maximum number permitted | — | — | — | — |
Size allocation (maximum % of window area) | — | 20% | 20% | 20% |
Internal lighting | — | — | — | — |
External lighting | — | — | — | — |
Electronic Changeable Copy Signs | Any sign, or portion thereof, on which characters, letters, or illustrations are changed mechanically or electronically in the field without altering the face or surface of the sign, including without limitation, an electronic or mechanical message center. | |||
|---|---|---|---|---|
R-1 | NC | VC | I | |
Permitted in Zone | NP | NP | NP | P |
Maximum number permitted | — | — | — | 1 per lot |
Size and setback requirements | See freestanding sign requirements. | |||
Temporary Signs | Any sign that is used only for a short, specifically limited time and that is not permanently mounted. | |||
|---|---|---|---|---|
R-1 | NC | VC | I | |
Permit requirement guidelines for specific sign types shall also be applied as defined above. | ||||
Maximum number permitted | 1 per lot | 1 per lot | 1 per lot | 1 per lot |
Internal lighting | NP | NP | NP | NP |
External lighting | See applicable sign type above. | |||
Table 54-1: Minimum Plant Size in Buffer | |||
|---|---|---|---|
Plant Material | Side or Rear Yards | All Other Landscaped Areas | |
1. Trees | |||
Deciduous | 1 1/2 inch caliper | 2 1/2 inch caliper | |
Evergreen | 4 feet (height) | 5 feet (height) | |
2. Shrubs | |||
Deciduous | 15 inches (height) | 24 inches (height) | |
Evergreen | 12 inches (height) | 18 inches (height) | |
Development Standards
Table 50-1: Sound Levels | |||
|---|---|---|---|
District | Level Limit db(A) | 11:00 p.m. to 7:00 a.m. Level Limit db(A) | |
A. Residential | 60 | 55 | |
B. Commercial | 70 | 65 | |
C. Industrial | 80 | 75 | |
Table 51-1: Minimum Aisle Widths | |||
|---|---|---|---|
Angle of Parking | Minimum Aisle Width | ||
Two-way Traffic (feet) | One-way Traffic (feet) | ||
1. Ninety-degree parking | 24 | 22 | |
2. Sixty-degree parking | 23 | 18 | |
3. Forty-five-degree parking | 21 | 13 | |
4. Parallel parking | 19 | 13 | |
Table 51-2: Minimum Size of Parking Spaces | |||
|---|---|---|---|
Angle of Parking | Minimum Width (feet) | Minimum Length (feet) | |
1. Ninety-degree parking | 9 | 18 | |
2. Sixty-degree parking | 9 | 18 | |
3. Forty-five-degree parking | 9 | 18 | |
4. Parallel parking | 8 | 22 | |
Table 51-3: Access Driveway Dimensions by Use | |||
|---|---|---|---|
Use | Minimum Width (feet) | Maximum Width (feet) | |
1. Single-family | 10 | 20 | |
2. Multifamily | 16 (combined drive) | 20 | |
3. All other uses | 12 (one-way) 20 (two-way) | 30 | |
Table 51-4: Minimum Parking Space Requirements by Use | ||
|---|---|---|
Use Classification | Minimum Parking Requirement | |
A. Residential | ||
Single-family dwelling | 2 per dwelling unit | |
Two-family dwelling | 2 per dwelling unit | |
Multifamily dwelling, studio to 1-bedroom | 1 per dwelling unit | |
Multifamily dwelling, 2-3 bedroom units | 2 per dwelling unit | |
Senior housing | 1 per dwelling unit | |
Boarding houses | 2 spaces + 0.5 per rooming unit | |
B. Government/Cultural/Educational | ||
Schools, elementary and intermediate | 1 per employee + 2 per classroom | |
Schools, secondary | 1 per 10 students + 1 per employee + 2 per classroom | |
Schools, occupational/skill training | 1 per instructor + 1 per 3 students | |
Religious institution | 1 per 3.5 seats | |
Community center | 6 per 1,000 square feet | |
Library | 2 per 1,000 square feet | |
Auditorium | 1 per 3.5 seats | |
Private club | 8 per 1,000 square feet | |
Recreational: | ||
Bowling alley | 2 per lane | |
Skating rink | 1 per 5 persons (based on capacity) | |
Swimming pool | 1 per 4 persons (based on capacity) | |
Tennis club | 3 per court | |
Day-care or nursery | 1 per 6 enrolled + 1 per employee | |
Hospital | 1 per bed + 1.5 per employee (during maximum shift) | |
Medical clinic, medical office | 5 per 1,000 square feet | |
Nursing home | 1 per 2 beds + 1.5 per employee (during maximum shift) | |
C. Commercial/Retail | ||
General retail | 3 per 1,000 square feet | |
Food store | 5 per 1,000 square feet | |
Convenience store | 5 per 1,000 square feet | |
Home occupations | Maximum of 2 spaces, in addition to residential requirement | |
D. Service | ||
Bank | 2 per 1,000 square feet | |
Drinking establishment/tavern/nightclub | 5 per 1,000 square feet | |
Bed-and-breakfast | 2 spaces + 1 per guest bedroom | |
Barbershop/beauty salon | 1.5 per chair | |
Dry cleaning/laundromat | 2 per 1,000 square feet | |
Hotel/motel | 1 per room + 1 for every employee on a single shift | |
Funeral homes | 10 per 1,000 square feet | |
Office, professional or business | 3 per 1,000 square feet | |
Restaurant, carry-out | 2 per 1,000 square feet | |
Restaurant, drive-through | 1 per employee + 4 per 1,000 square feet | |
Restaurant, sit-down | 5 per 1,000 square feet | |
E. Vehicle-Related | ||
Vehicle repair/service or gas station | 2 per bay | |
Vehicle sales | 2 per employee | |
Vehicle rental | 1 per 1,000 square feet floor area | |
Car wash | 1 per employee | |
F. Industrial/Manufacturing | ||
All uses | 1 per employee during maximum shift | |
Table 51-5: Minimum Space Dimensions | ||||
|---|---|---|---|---|
Class of Loading Space | Minimum Width (feet) | Minimum Length (feet) | Minimum Height (feet) | |
1. A (for semi-truck vehicles) | 14 | 50 | 15 | |
2. B (for other vehicles) | 12 | 25 | 14 | |
Table 51-6: Number of Loading Spaces Required | |||
|---|---|---|---|
Gross Floor Area (square feet) | Number | Class | |
1. Less than 4,000 | 0 | — | |
2. 4,000 to 15,000 | 1 | B | |
3. 15,000 to 30,000 | 1 | A | |
4. 30,000 or greater | 1 each | A and B | |
5. Each additional 50,000; or fraction thereof | 1 | A | |
Table 52-1 Table of Sign Regulations | ||||
|---|---|---|---|---|
R-1 | NC | VC | I | |
Zoning District | Village Residential | Neighborhood Commercial | Village Center | Industrial |
Freestanding Signs (Monument) | Any sign not affixed to a building constructed at grade level with continuous foundation. | |||
|---|---|---|---|---|
R-1 | NC | VC | I | |
Permitted in Zone | NP | P | NP | P |
Maximum number permitted | — | 1 per lot | — | 1 per lot |
Maximum area (square feet) | — | 6 | — | 50 |
Maximum height (feet) | — | 5 | — | 6 |
Setback (feet) | — | 10 | — | 10 |
Internal lighting | — | NP | — | P |
External lighting | — | P | — | P |
Wall Signs | Any sign fastened to a building or structure in such a manner that the wall becomes the supporting structure for or forms the background surface of the sign. The sign will not project more than 18 inches from the building or structure. | |||
|---|---|---|---|---|
R-1 | NC | VC | I | |
Permitted in Zone | P | P | P | P |
Maximum number permitted | 1 per structure | 1 per structure | 1 per use | 1 per use |
Size allocation NOTE: *whichever is less | 2 square feet | 20% or 12 square feet* | 20% or 2 square feet per linear foot of frontage* | 100 square feet |
Maximum height (feet) | — | — | 4 | — |
Internal lighting | NP | NP | P | P |
External lighting | P | P | P | P |
Projecting Signs | A sign wholly or partly dependent upon a building for support and which projects more than 18 inches from the building. | |||
|---|---|---|---|---|
R-1 | NC | VC | I | |
Permitted in Zone | NP | P | P | P |
Maximum number permitted | — | 1 per structure | 1 per use | 1 per use |
Maximum area (square feet) | — | 6 | 20 | 20 |
Vertical clearance (feet) | — | 8 | 8 | 8 |
Internal lighting | — | NP | NP | P |
External lighting | — | P | P | P |
Maximum projection (feet) | — | 4 | 4 | 4 |
Suspended Signs | A sign attached to and supported by the underside of a horizontal plane. | |||
|---|---|---|---|---|
R-1 | NC | VC | I | |
Permitted in Zone | NP | P | P | P |
Maximum number permitted | — | 1 per structure | 1 per use | 1 per use |
Maximum area (square feet) | — | 3.5 | 3.5 | 3.5 |
Vertical clearance (feet) | — | 8 | 8 | 8 |
Internal lighting | — | NP | NP | P |
External lighting | — | P | P | P |
Awning and Canopy Signs | Any sign that is a part of or attached to an awning, canopy, or other fabric, plastic, or structural protective cover over a door, entrance, window, or outdoor service area. | |||
|---|---|---|---|---|
R-1 | NC | VC | I | |
Permitted in Zone | P | P | P | P |
Maximum number permitted | 1 per structure | 1 per structure | 1 per structure | 1 per structure |
Internal lighting | NP | NP | NP | NP |
External lighting | NP | NP | NP | NP |
NOTE: Awning signs may only be placed in the area encompassed by the bottommost six inches of the awning edge that runs parallel to the ground. | ||||
Window and Door Signs | A non-electric sign applied or attached to the interior of a window or door or within three feet of the interior which can be seen from the exterior. | |||
|---|---|---|---|---|
R-1 | NC | VC | I | |
Permitted in Zone | NP | P | P | P |
Maximum number permitted | — | — | — | — |
Size allocation (maximum % of window area) | — | 20% | 20% | 20% |
Internal lighting | — | — | — | — |
External lighting | — | — | — | — |
Electronic Changeable Copy Signs | Any sign, or portion thereof, on which characters, letters, or illustrations are changed mechanically or electronically in the field without altering the face or surface of the sign, including without limitation, an electronic or mechanical message center. | |||
|---|---|---|---|---|
R-1 | NC | VC | I | |
Permitted in Zone | NP | NP | NP | P |
Maximum number permitted | — | — | — | 1 per lot |
Size and setback requirements | See freestanding sign requirements. | |||
Temporary Signs | Any sign that is used only for a short, specifically limited time and that is not permanently mounted. | |||
|---|---|---|---|---|
R-1 | NC | VC | I | |
Permit requirement guidelines for specific sign types shall also be applied as defined above. | ||||
Maximum number permitted | 1 per lot | 1 per lot | 1 per lot | 1 per lot |
Internal lighting | NP | NP | NP | NP |
External lighting | See applicable sign type above. | |||
Table 54-1: Minimum Plant Size in Buffer | |||
|---|---|---|---|
Plant Material | Side or Rear Yards | All Other Landscaped Areas | |
1. Trees | |||
Deciduous | 1 1/2 inch caliper | 2 1/2 inch caliper | |
Evergreen | 4 feet (height) | 5 feet (height) | |
2. Shrubs | |||
Deciduous | 15 inches (height) | 24 inches (height) | |
Evergreen | 12 inches (height) | 18 inches (height) | |