The following guidelines apply to all development occurring within the M districts and are intended to facilitate high-quality development that complements the character of Tulare.
(1) For industrial complexes that include multiple buildings (such as an industrial campus), the placement of structures that create opportunities for plazas, courts, or gardens is encouraged. Setback areas may be used to provide space for employee lunch/break areas.
(2) Where industrial uses are adjacent to non-industrial uses, buffering techniques such as setbacks, screening, and landscaping shall be provided to reduce/eliminate any negative impacts of industrial operations.
(B) Parking and circulation. Important design considerations for parking and circulation include the location of ingress and egress points, on-site pedestrian and vehicle traffic circulation patterns, and service functions. The purpose is to ensure efficient circulation, safety, and visual quality.
(1) Site access and internal circulation should be designed in a manner that emphasizes safety and efficiency. Consideration should be given to the separation of employee/customer parking and commercial vehicle operations (trucking, delivery, etc.).
(2) Parking facilities shall be designed so that vehicles can move from one area to another on the same site without entering the street, and with an adequate amount of on-site parking to prevent trucks and other vehicles from parking or idling on public streets.
(3) Separate vehicle and pedestrian circulation systems should be considered in the design of parking facilities. Pedestrian linkages between buildings in multi-structure industrial developments shall be implemented if applicable. To improve vehicle circulation, parking aisles, signs, and drive aisle pavement markings shall identify onsite circulation patterns and should be aligned with vehicle circulation routes.
(4) Facilities shall be designed to provide common driveways to provide access to adjacent sites and improve on-site circulation.
(5) Parking driveways (access points) shall be located as far as possible from street intersections to avoid traffic problems. The number of access points shall be limited to the minimum amount necessary to provide adequate circulation.
(6) Parking lots shall be screened from adjoining streets by the use of low earth berms, walls, landscaping, or a combination of these methods.
(7) Industrial sites shall be designed to accommodate all parking needs generated by the use. The use of the public street for parking, staging, and maintenance of trucks is not permitted. Signs shall be installed in adjacent residential areas noting that facility truck and employee parking and maintenance of trucks is prohibited in residential areas and public streets.
(8) Parking lots shall be designed to accommodate solid waste pick-up service without excessive backing-up of service trucks.
(9) Facilities shall be designed to provide a separate entrance for heavy-duty trucks accessible via designated truck routes or major streets away from sensitive receptors and local residential streets.
(1) Loading facilities shall be located out of sight of the public-of-way, to the extent possible. Loading docks are most appropriately located at the rear of buildings, however when the rear of buildings is adjacent to noise-sensitive land uses, loading dock locations should be planned to minimize associated noise impacts on surrounding land uses .
(2) Highly visible loading facilities shall be screened from view particularly if it is not possible to locate them at the rear of the building.
(3) For industrial sites within 500 feet of sensitive receptors, heavy-duty trucks shall have a separate entrance accessible via a truck route, arterial road, major thoroughfare, or a local road that predominantly serves commercial oriented uses.
(4) Truck entry, exit, and internal circulation shall be located away from sensitive receptors. Heavy-duty diesel truck drive aisles shall be prohibited from being used on sides of the building that are directly adjacent to a sensitive receptor property line.
(5) Loading facilities shall be located so that vehicles are not required to use public streets backing into loading docks.
(1) Avoid long, blank building facades, particularly on walls visible from the public right-of-way. Facades with varied setbacks are encouraged. If possible, wall planes should not run in one continuous direction for more than 50 feet without an offset.
(2) All elevations to a building should be architecturally treated to avoid monotonous overall design.
(3) Window and doors are key elements of a structure's form and should relate to the scale of the facade on which they appear. Windows and doors can help establish character by their rhythm, spacing, and variety. Recessed openings further work to provide depth and contrast on elevation planes.
(4) Metal buildings should be architecturally designed, providing variety and visual interest to the streetscape.
(5) All roof-mounted equipment shall be screened from public view by materials similar to those used in the overall structure. Mechanical equipment should be located below the highest vertical element of the building.
(6) Design elements that are undesirable and should be avoided include:
(a) Highly reflective surfaces.
(b) Large blank, unarticulated wall surfaces.
(c) Exposed, treated block walls.
(d) Poorly designed mansard roofs on a portion of the roofline.
(e) Materials with high maintenance requirements, such as stained wood or shingles.
(1) The design of light fixtures should be architecturally compatible with on-site buildings.
(2) All light fixtures must be shielded to confine the spread of light within the boundaries of the site, particularly where uses sensitive to exterior lighting are located in close proximity.
(1) Driveways shall conform to city industrial driveway approach standards.
(2) Driveways designed for heavy truck usage shall not exceed 60 feet in width without approval from the City Engineer.
(3) Minimum separation between on-site driveways shall be 100 feet.
(G) Monitored electrified security fences.
(1) 'Monitored electrified security fence' means a perimeter alarm system with an assembly of battery-powered equipment, including, but not limited to, a monitored alarm device and an energizer which is intended to periodically deliver pulses to a security fence, a battery charging device used exclusively to charge the system's battery, and other integrated components.
(2) The monitored perimeter security fence system shall transmit a signal to an alarm monitoring business in response to an intrusion or burglary. The system shall not directly connect to or call law enforcement. The business must first verify the alarm event prior to requesting the deployment of law enforcement.
(3) The design, construction, and use of monitored electrified security fences shall be allowed, subject to the following requirements:
(a) IEC Standard 60335-2-76. Unless otherwise specified herein, Monitored Electrified Security Fences shall be constructed and operated in conformance with the specifications set forth in International Electrotechnical Commission (IEC) Standard No. 60335-2-76, current edition.
(b) Power source. The energizer for monitored electrified security fences must be driven by a commercial storage battery not to exceed 12 volts DC. The storage battery is charged by a solar panel.
(c) Perimeter barrier. Monitored electrified security fences shall be installed behind a minimum five-foot-high, maximum seven-foot-high, non-electrified perimeter barrier. On all new fencing, a minimum of six feet high shall apply.
(d) Emergency gate access. Before a monitored perimeter security fence is activated, a Knox device shall be approved by the Fire Department. The Knox device will be installed at the main entry gate and fully functional at all times when the monitored electrified security fence is operational.
(e) Setback. The monitored electrified security fence shall be setback four inches to 12 inches from the non-electrified perimeter barrier.
(f) Height. Monitored electrified security fences shall be a minimum of two feet above the non-electrified perimeter barrier, but in no event, more than ten feet in height.
(g) Warning signs. Monitored electrified security fences shall be clearly identified with warning signs that read: 'Warning-Electric Fence' at intervals of not less than 30 feet.
(4) It shall be unlawful for any person to install, maintain, or operate a monitored electrified security fence in violation of this chapter.
(Ord. 2025-01, passed 1-7-2025)