General Provisions and Design Standards
Type | Design Capacity (years) |
|---|---|
Drainage systems (1) | 25 |
Drainage structures (2) | 100 |
Open channels | As determined by Borough Engineer |
NOTES: | |
|---|---|
(1) | The term "drainage systems" refers to the composite of all drainage infrastructure improvements. |
(2) | The term "drainage structures" refers to particular drainage infrastructure improvements such as bridges and culverts. |
Angle of Parking Space (degrees) | One-Way Aisle (feet) | Two-Way Aisle (feet) |
|---|---|---|
90 | 25 | 25 |
60 | 18 | 20 |
45 | 15 | 20 |
30 | 13 | 18 |
Parallel | 13 | 18 |
Table 1: | |
|---|---|
Off-site Use/Designated Area | Separation Distance |
Single-family or duplex residential units[1] | 200 feet or 300% height of tower whichever is greater |
Vacant single-family or duplex residentially zoned land which is either platted or has preliminary subdivision plan approval which is not expired | 200 feet or 300% height of tower[2] whichever is greater |
Vacant unplatted residentially zoned lands[3] | 100 feet or 100% height of tower whichever is greater |
Existing multi-family residential units greater than duplex units | 100 feet or 100% height of tower whichever is greater |
Nonresidentially zoned lands or nonresidential uses | None; only setbacks apply |
Table 2: | ||||
|---|---|---|---|---|
Existing Towers - Types | Lattice | Guyed | Monopole 75 Ft. in Height or Greater | Monopole Less Than 75 Ft. in Height |
Lattice | 5000 | 5000 | 1,500 | 750 |
Guyed | 5000 | 5000 | 1,500 | 750 |
Monopole 75 Ft. in Height or Greater | 1,500 | 1,500 | 1,500 | 750 |
Monopole Less Than 75 Ft. in Height | 750 | 750 | 750 | 750 |
General Provisions and Design Standards
Type | Design Capacity (years) |
|---|---|
Drainage systems (1) | 25 |
Drainage structures (2) | 100 |
Open channels | As determined by Borough Engineer |
NOTES: | |
|---|---|
(1) | The term "drainage systems" refers to the composite of all drainage infrastructure improvements. |
(2) | The term "drainage structures" refers to particular drainage infrastructure improvements such as bridges and culverts. |
Angle of Parking Space (degrees) | One-Way Aisle (feet) | Two-Way Aisle (feet) |
|---|---|---|
90 | 25 | 25 |
60 | 18 | 20 |
45 | 15 | 20 |
30 | 13 | 18 |
Parallel | 13 | 18 |
Table 1: | |
|---|---|
Off-site Use/Designated Area | Separation Distance |
Single-family or duplex residential units[1] | 200 feet or 300% height of tower whichever is greater |
Vacant single-family or duplex residentially zoned land which is either platted or has preliminary subdivision plan approval which is not expired | 200 feet or 300% height of tower[2] whichever is greater |
Vacant unplatted residentially zoned lands[3] | 100 feet or 100% height of tower whichever is greater |
Existing multi-family residential units greater than duplex units | 100 feet or 100% height of tower whichever is greater |
Nonresidentially zoned lands or nonresidential uses | None; only setbacks apply |
Table 2: | ||||
|---|---|---|---|---|
Existing Towers - Types | Lattice | Guyed | Monopole 75 Ft. in Height or Greater | Monopole Less Than 75 Ft. in Height |
Lattice | 5000 | 5000 | 1,500 | 750 |
Guyed | 5000 | 5000 | 1,500 | 750 |
Monopole 75 Ft. in Height or Greater | 1,500 | 1,500 | 1,500 | 750 |
Monopole Less Than 75 Ft. in Height | 750 | 750 | 750 | 750 |