search icon

Brunswick City Zoning Code

BRUNSWICK ZONING ORDINANCE APPENDIX D

SUMMARY OF APPLICATION REQUIREMENTS

TABLE D.1 Sketch Plan Final Plan Common Development Plan Conditional Use or
General Application form and fee X X X X
Name of development X X X X
Existing zoning district and overlay designations X X X X
Location map X X X X
Names of current owner(s) of subject parcel and abutting parcels X X X
Names of engineer and surveyor; and professional registration numbers of those who prepared the plan X X X
Location of features, natural and artificial, such as water bodies, wetlands, streams, important habitats, vegetation, railroads, ditches and buildings X X X X
Documentation of Right, Title and Interest X X X X
Drafts of legal documents appropriate to the application, including: deeds, easements, conservation easements, deed restrictions or covenants, home/property owners association declarations and by-laws, and such other agreements or documents as are necessary to show the manner in which common areas will be owned, maintained, and protected X X X
Survey, Topography, & Existing Conditions Scale, date, north point, and area X X X X
A survey submitted (stamped for final plan submittal) by a professional surveyor with a current license by the State of Maine Board of Licensure for Professional Surveyors X X X
Boundaries of all lots and tracts with accurate distances and bearings, locations of all permanent monuments property identified as existing or proposed X X
Existing easements associated with the development X X X X
Location of existing utilities; water, sewer, electrical lines, and profiles of underground facilities X X
Survey, Topography, & Existing Conditions Existing location, size, profile and cross section of sanitary sewers; description, plan and location of other means of sewage disposal with evidence of soil suitability X X
Topography with contour intervals of not more than two (2) feet X X
A Medium Intensity Soil Survey, available from the Cumberland County Soil and water Conservation District,. The Planning Board may require a Class A (high intensity) Soil Survey, prepared in accordance with the standards of the Maine Association of Professional Soil Scientists, if issues of water quality, wetlands or other natural constraints are noted. X X
Existing locations of sidewalks X X X
A delineation of wetlands, floodplains, important habitats, and other environmentally sensitive areas X X
Approximate locations of dedicated public open space, areas protected by conservation easements and recreation areas X X X
Infrastructure - Proposed Name, location, width of paving and rights-of-way, profile, cross-section dimensions, curve radii of existing and proposed streets; profiles of center-lines of proposed streets, at a horizontal scale of one (1) inch = 50 feet and vertical scale of one (1) = five (5) feet, with all evaluations referred to in U.S.G.S. datum X X
Proposed easements associated with the development X X X
Kind, location, profile and cross-section of all proposed drainage facilities, both within and connections to the proposed development, and a storm-water management plan in accordance with Section X X
Location of proposed utilities; water, sewer, electrical lines, and profiles of underground facilities. Tentative locations of private wells. X X
Proposed location, size, profile and cross section of sanitary sewers; description, plan and location of other means of sewage disposal with evidence of soil suitability X X
Proposed locations, widths and profiles of sidewalks X X
Locations and dimensions of proposed vehicular and bicycle parking areas, including proposed shared parking arrangement if applicable. X X X
Infrastructure - Proposed Grading, erosion control, and landscaping plan; proposed finished grades, slopes, swells, and ground cover or other means of stabilization X X
Storm water management plan for the proposed project prepared by a professional engineer X X
The size and proposed location of water supply and sewage disposal systems X X
Where a septic system is to be used, evidence of soil suitability X X X
A statement from the General Manager of the Brunswick Sewer District as to conditions under which the Sewer District will provide public sewer and approval of the proposed sanitary sewer infrastructure X X X
A statement from the Fire Chief recommending the number, size and location of hydrants, available pressure levels, road layout and street and project name, and any other fire protection measures to be taken X X X
A statement from the General Manager of the Brunswick and Topsham Water District as to conditions under which public water will be provided and approval of the proposed water distribution infrastructure X X X
Proposed Development Plan Lighting plan showing details of all proposed lighting and the location of that lighting in relation to the site X X
Reference to special conditions stipulated by the Review Authority X X X
Proposed ownership and approximate location and dimensions of open spaces for conservation and recreation. Dedicated public open specs, areas protected by conservation easements, and existing and proposed open spaces or recreation areas and potential connectivity to adjoining open space. X X
When applicable, a table indicating the maximum number of lots permitted based upon the applicable dimensional requirements, the number of lots proposed, and the number of lots permitted to be further subdivided. X X X X
Building envelopes showing acceptable locations for principal and accessory structures, setbacks and impervious coverage X X
Proposed Development Plan Disclosure of any required permits or, if a permit has already been granted, a copy of that permit X X X
A statement from the General Manager of the Brunswick and Topsham Water District regarding the proposed development if located within an Aquifer Protection Zone X X X
A plan of all new construction, expansion and/or redevelopment of existing facilities, including type, size, footprint, floor layout, setback, elevation of first floor slab, storage and loading areas X X X
An elevation view of all sides of each building proposed indicating height, color, bulk, surface treatment, signage and other features as may be required by specific design standards X X
A circulation plan describing all pedestrian and vehicle traffic flow on surrounding road systems X X
A site landscaping plan indicating grade change, vegetation to be preserved, new plantings used to stabilize areas of cut and fill, screening, the size, locations and purpose and type of vegetation X X X
Number of lots if a subdivision X X X X
A plan showing all ten (10) inch caliper trees to be removed as a result of the development proposal X X
All applicable materials necessary for the Review Authority to review the proposal in accordance with the criteria of Chapter 5. X X X
Any additional studies required by the Review Authority X X X

 

(Ord. of 7-15-24)