Design Regulations and Guidelines
![]() Figure 1: Building Frontages |
![]() Figure 2: Multi-Level Building with Retail or Office on Ground Level, Retail, Office and Residential at Upper Levels |
![]() Figure 3: Pedestrian Scale Elements |
![]() Figure 4: Pedestrian Street |
![]() Figure 5: Streets Designation |
![]() Figure 6: Characteristics for Streetscapes on Wilmington Drive and Ross Street |
![]() Figure 7: Typical Plaza Features |
![]() Figure 8: Varied Building Heights and Massing Develops Urban Scale |
![]() Figure 9: Illustrates the Intent of the Provisions to Modulate a Long Facade |
![]() Figure 10: Building Focal Point |
![]() Figure 11: Example of Treating a Secondary Building Wall with Trellis and Landscaping |
![]() Figure 12: Secondary Building Wall with Unit Patterning and Display Window |
![]() Figure 13: Roof Configuration |
![]() Figure 14: Service Area Locations and Screening |
Figure 25.71.220(a) Conceptual Location of Old Fort Lake Subarea’s Arterial Streets and Base Trail Network ![]() |
Figure 25.71.230(b) Gateway Streetscape Cross-Section ![]() |
NOTES: | |
|---|---|
1. | Different pavement styles shall be used to distinguish the bicycle portion of the path from pedestrian use. The most common technique is to use an asphalt surface for the bicycle lane and concrete for the pedestrian path. Also, the landscaped areas may include lighting and furnishings per the city's public works standards. |
2. | Turn lanes may be added when necessary. |
3. | A landscaped center median may also be included along some or all segments where a center turn lane is not needed. |
4. | Landscape areas shall integrate low impact development techniques (i.e., bioretention facilities, rain gardens, etc.) unless demonstrated as infeasible. |
5. | Pedestrian-scaled lighting shall be provided along the shared use paths. |
NOTE: Below is a photo example of similar recent shared-use path constructed in Bellevue, WA. ![]() |
Figure 25.71.230(c) Arterial Streetscape Cross-Sections ![]() |
STANDARDS: | ||
|---|---|---|
1. | For the Arterial loop (around Old Fort Lake), the shared use path shall be located on the inside, so that no crossing of the arterial is needed to complete a full trail loop. | |
2. | Parallel parking pockets (seven feet wide) may be integrated into the street design, provided the right-of-way is widened sufficient to accommodate such parking pockets (without reducing the width of other streetscape components). | |
3. | Turn lanes may be added when necessary. | |
4. | Landscape areas shall integrate low impact development techniques (i.e., bioretention facilities, rain gardens, etc.) unless demonstrated as infeasible. | |
5. | Special shared-use path provisions: | |
a. | Provide clear, coordinated, and safe transitions for pathway users at intersections. | |
b. | Provide pedestrian-scaled lighting. | |
c. | Provide signage for wayfinding. | |
d. | Provide water, garbage, bicycle parking, and dog stations at key intersections and trailheads. | |
Figure 25.71.230(d) Generalized Local Streetscape Cross-Section ![]() |
Table 25.71.240(a) Maximum Block Face and Perimeter Length | |||
|---|---|---|---|
Zone | Maximum Block Face Length | Maximum Block (Bound by Public Streets) Perimeter Length | |
Between Public Streets and TBCs or Between TBCs | Between Public Streets | ||
COM and ENT | 300 | 500 | 2,000 |
MF | 400 | 600 | 2,400 |
SF+D | 500 | 750 | 3,000 |
NB, CIV | 600 | 1,000 | 4,000 |
![]() | |||
Figure 25.71.250(a) Woonerf Examples ![]() |
Figure 25.71.250(b) Cross-Section of Minimum Regulations and Examples of a Landscaped Passageway ![]() |
Figure 25.71.260(a) Good Park Integration Examples ![]() |
A. | Circular park surrounded by a street functions as the neighborhood’s focal point. |
B. | Small parks are bordered by streets on one or two sides with pathways and front yards along other sides. Note that alleys provide access to the adjacent homes. |
C. | Rectangular-shaped neighborhood park bound by streets on all four sides. |
D. | Small “green” is bound by pathways and townhouses on three sides and a street on one side. |
Table 25.71.280(a) Off-Street Parking Regulations for Old Fort Lake Subarea (Minimum Number of Parking Spaces Required) | |
|---|---|
Use Categories | Minimum Number of Parking Spaces Required |
NONRESIDENTIAL (spaces per square feet of gross floor area, unless otherwise noted) | |
Automotive repair | 1/500 SF |
Child day care center | 3/worker at maximum shift |
Personal services use | 1/1,000 SF |
Restaurants, taverns, breweries | 10/1,000 SF open to the public |
Elementary schools | 1 space per employee plus 2 per classroom |
Middle/junior high schools | 1 space per employee plus 4 per classroom |
High schools | 1 per employee plus 1 space per 10 students |
Government services, general | 2/1,000 SF |
Clinics | 2/1,000 SF |
Retail uses | 3/1,000 SF |
Banks and credit unions | 2/1,000 SF |
Office | 2/1,000 SF |
Hotels | 1/unit or suite |
Light manufacturing | 0.9/1,000 SF |
Research and development | 0.9/1,000 SF |
Uses not otherwise categorized | As determined by community development director |
RESIDENTIAL* (spaces per dwelling unit) | |
MULTIFAMILY USES | |
Studio + 1-bedroom | 1/unit |
2-bedroom | 1.5/unit |
3-bedroom or more | 1.75/unit |
Adult retirement community | 0.5/unit |
OTHER RESIDENTIAL | |
Detached single family | 2/lot |
Middle housing types on lots no greater than 6,000 SF before any zero-lot line subdivision or lot split | 1/unit |
Middle housing types on lots greater than 6,000 SF before any zero-lot line subdivision or lot split | 2/unit |
Accessory dwelling unit on lots smaller than 6,000 SF before any zero lot line subdivision or lot split | 1/unit |
Accessory dwelling unit on lots greater than 6,000 SF before any zero lot line subdivision or lot split | 2/unit |
Assisted living facilities | 0.5/unit |
Nursing homes | 0.8/bed |
Co-living housing | 0.25/sleeping unit |
*Note, some developments within one-quarter mile of frequent transit may be eligible for a parking minimum exception per HB 1923, modified by HB 2343, allowing a minimum of 0.75 stalls per unit. |
Table 25.71.310(a) Summary of Block Frontage Standards | ||
|---|---|---|
Block Frontage Type | Details | |
Storefront | ![]() | • No ground-level parking adjacent to the street. • Special transparency, weather protection, and entry requirements. • Minimum commercial space height and depth. • No ground floor residential uses except for live/ work units on select storefront designated blocks where the storefront space meets height and depth standards. |
Landscaped | ![]() | • Ground-level parking placed to the side or rear of buildings. • Landscaping to soften facades and buffer parking areas. • Minimum facade transparency requirements per use and setback. |
Secondary | ![]() | • Ground-level parking placed to the side or rear of buildings. • Landscaping to soften facades of non-storefronts and buffer parking areas. • Minimum facade transparency requirements per use and setback. |
Basic | ![]() | • No restrictions on parking lot location (except for landscaping standards). • Landscaping to soften facades of nonstorefronts. • Minimum facade transparency requirements per use and setback. |
Table 25.71.310(b) Explanation of Transparency Standards | ||
|---|---|---|
Transparency Zones by Building and Frontage Type | ||
Storefront ![]() The transparency zone is on the ground floor between 30 inches and 10 feet above sidewalk grade | Ground Floor Nonresidential and Nonstorefront ![]() The transparency zone is between 30 inches and 8 feet above grade | Multifamily Buildings ![]() All vertical surfaces of the facade are used in the calculations |
Other Transparency Provisions | ||
Windows shall be transparent. Ground level window area for storefronts and other nonresidential uses that is mirrored, reflective, darkly tinted, covered, frosted, or perforated in any manner that obscures visibility into the building shall not count as transparent window area. See also DMC § 25.71.310(3). Exception: Window signs may be counted as transparent window area provided the areas generally around the sign are transparent. | ![]() Unacceptable: Frosted glass obscuring view into storefront. | ![]() Unacceptable: Window sign covering transparency zone. |
Display windows may be used for up to 50 percent of nonresidential transparency requirements provided they are at least 30 inches deep and allow changeable displays. Tack-on display cases as in the right example do not qualify as transparent window area. | ![]() Acceptable: Integrated display windows. | ![]() Unacceptable: Tack-on display cases |
Figure 25.71.310(a) Storefront Block Frontages Vision and Key Standards ![]() |
Table 25.71.310(c) Storefront Block Frontage Standards | ||
|---|---|---|
The → symbol refers to DEPARTURE opportunities in DMC § 25.71.310(4)(c). | ||
Element | Standards | Additional Provisions and Examples |
Ground Level | ||
Land use | Nonresidential uses are required on the ground level. | Lobbies and accessory uses associated with upper-floor hotel/motel, business service, and multifamily uses are allowed provided they are limited to 25% of all storefront block frontages (measured separately for each block). |
Floor to ceiling height | 15' minimum | Applies to the area within the minimum retail space depth. |
Retail space depth | 40' minimum → | Applies to the entire width of the retail space. |
Building Placement | Buildings shall be placed at the back edge of the required sidewalk. Additional setbacks may be allowed for a wider sidewalk or where a public space is provided between the sidewalk and the building. | ![]() |
Building Entrances | Primary building entrances shall face the street. For corner buildings, primary entrances for ground-level uses may face either street or the street corner. | ![]() Examples of building placement and building entrances. |
Facade Transparency | At least 60% of the transparency zone. → | See DMC § 25.71.310(3) for additional clarification on transparency standards. |
Weather Protection | Weather protection over the sidewalk is required along at least 75% of the building’s facade, and it shall be a minimum of 6' deep (drip lines shall be at least that far from the face of the building). → Additional standards: • Weather protection shall have 10' to 15' of vertical clearance. • Weather protection shall not interfere with existing street trees, utility poles, street signs, or extend beyond the edge of the sidewalk. | • Vinyl or plastic awnings or canopies are prohibited. • Any canopy or awning over a public sidewalk should be a permanent architectural element. • The building’s architectural details should not be concealed by awnings or canopies. • Awning shapes should relate to the shape of the facade’s architectural elements. • Transparent canopies and under-canopy signs and lighting are encouraged. |
Parking Location | New ground-level (surface or structured) parking adjacent to the street is prohibited, including parking lot and garage entries and driveways. Parking may be placed below, above, and/or behind storefronts. | |
Streetscape Design | Sidewalks and planting strips shall comply with arterial street design cross-section for commercial areas as set forth in Figure 25.71.230(2). | |
Figure 25.71.310(b) Landscaped Block Frontages Vision Examples and Key Standards ![]() |
Table 25.71.310(d) Landscaped Block Frontage Standards | ||
|---|---|---|
The → symbol refers to DEPARTURE opportunities in DMC § 25.71.310(5)(d). | ||
Element | Standards | Additional Provisions and Examples |
Ground Level Land use | Any use permitted by Chapter 25.58 DMC. | |
Building placement | • Ten-foot minimum setback. • Twenty-foot maximum setback. • Covered entries and porches are allowed to project up to six feet into this required setback. • Additional setbacks may be required where future right-of-way need and/or acquisitions have been identified in city plans. | ![]() |
Building entrances | At least one public or shared building entry shall be visible from the sidewalk and feature direct physical access from the sidewalk. → | • Primary private entrances facing the street for ground level residential units are encouraged. See related standards in DMC § 25.71.450. |
Facade transparency | Shall have at least 25 percent transparency for buildings with ground level nonresidential uses. → Shall have at least 15 percent transparency for buildings with ground level residential uses. | See DMC § 25.71.310(3) for additional clarification on transparency standards. |
Weather protection | Weather protection at least three feet deep shall be provided over individual business and residential entries. Weather protection for shared entrances shall be at least five feet deep. | |
Parking location | Parking shall be located to the side, under, or rear of buildings. For multi-building developments, no more than 50 percent of the lot frontage can be occupied by off-street parking and driveways. | |
Landscaping Also see DMC § 25.71.320(h) | All areas between the sidewalk and the building must be landscaped, except for pathways, porches, decks, and plazas. Such landscaping shall include a mixture of evergreen and deciduous trees, shrubs, and ground cover. Landscaped areas may include rain gardens and other forms of stormwater management. Parking lots developed adjacent to the street (as allowed through the departure process) or golf course shall integrate a 10' wide landscape buffer meeting the requirements of a full screening buffer as defined in DMC § 25.10.020.060. | ![]() |
Sidewalk width | A six-foot sidewalk accompanied by a minimum five-foot landscape strip is required within the right-of-way adjacent to the front property line as well as adjoining arterial corridors. | |
Figure 25.71.310(c) Secondary Block Frontages Vision Examples and Key Standards ![]() |
Table 25.71.310(e) Secondary Block Frontage Standards | ||
|---|---|---|
The → symbol refers to DEPARTURE opportunities in DMC § 25.71.310(6)(c). | ||
Element | Standards | Additional Provisions and Examples |
Building placement | Buildings placed up to the sidewalk edge shall meet storefront block frontage standards in DMC § 25.71.310(4). Buildings not placed up to the sidewalk shall meet the landscaped block frontage standards in DMC § 25.71.310(5). Additional setbacks may be required where future right-of-way need and/or acquisitions have been identified in city plans. | See DMC § 25.71.310(9) for special design provisions associated with ground level residential uses in the multifamily zoning district adjacent to a sidewalk. |
Facade transparency | Any storefront buildings on these block frontages shall meet the storefront block frontage transparency standards above. → Nonresidential buildings with landscaped setbacks shall provide minimum transparency levels based on the setback: • Forty percent minimum for buildings designed with nonresidential uses on the ground floor within 10 feet of sidewalk. → • Twenty-five percent minimum for other buildings designed with nonresidential uses on the ground floor. → | See DMC § 25.71.310(3) for additional clarification on transparency standards. |
Parking location | Parking shall be located to the side or rear of buildings. For multi-building developments, no more than 50 percent of the lot frontage can be occupied by off-street parking and driveways →. Parking lots developed adjacent to the street or golf course shall comply with landscaping provisions of Chapter 25.90 DMC. | |
Table 25.71.310(f) Basic Block Frontage Standards | |
|---|---|
The → symbol refers to DEPARTURE opportunities in DMC § 25.71.310(7)(c). | |
Element | Standards |
Building placement | Buildings placed up to the sidewalk edge shall meet storefront block frontage standards in DMC § 25.71.310(4). Buildings not placed up to the sidewalk shall feature a 10-foot minimum street setback except where greater setbacks are required by the zone. |
Building entrances | Building entrances facing the street are encouraged. At a minimum, at least one building entry visible and directly accessible from the street is required. → Where buildings are set back from the street, pedestrian connections from the sidewalk are required. |
Facade transparency | • For storefronts, at least 60 percent. → • Other buildings designed with nonresidential uses on the ground floor within 10 feet of sidewalk, at least 30 percent. → • For multifamily, at least 15 percent. → |
Weather protection | At least three feet deep over primary business and residential entries. |
Parking location | There are no parking lot location restrictions, except for the following landscaped buffer requirements: Parking lots developed adjacent to the street shall integrate a 10-foot-wide landscape buffer with trees (75 percent deciduous at 25 feet on-center), low shrubs (one-twentieth of the landscaped area), and ground cover. → |
Landscaping | Building setback areas shall be landscaped per Chapter 25.90 DMC. Parking lots developed adjacent to the street and/ or golf course shall comply with landscaping provisions of Chapter 25.90 DMC. |
Sidewalk width | A five-foot sidewalk accompanied by a minimum five-foot landscape strip is required within the right-of-way adjacent to the front property line as well as adjoining arterial corridors. |
Figure 25.71.310(d) High Visibility Street Corner Examples ![]() Building A features cropped building corners with a change in materials and decorative elements. Building B uses a decorative canopy. Building C incorporates a plaza at the corner. |
Figure 25.71.310(e) Minimum Setback Between a Ground Floor Residence and Public Sidewalk ![]() |
Table 25.71.310(g) Dimensional Standards for Elevating Residential Units Near Public Streets | |
|---|---|
Facade Setback | Elevate the Ground Level of Adjacent Residential Units |
Front facade: < 10 feet from sidewalk (along a public street); or < five feet from an internal walkway or open space | Two to five feet above the grade of the public street |
Figure 25.71.310(f) Good Examples of Ground-Level Multifamily Frontages ![]() Building A uses inset stoops and ground level planters. Building B uses stoops with terraced planters. Building C is an at-grade example with a fenced yard between the sidewalk and dwelling. |
Figure 25.71.310(g) Acceptable Examples of Where Properties Front Onto Multiple Streets ![]() |
Table 25.71.320(a) Minimum Side and Rear Yard Setbacks | |
|---|---|
Context | Minimum Setback |
Two options for zero-foot setbacks when allowed by applicable zoning district: (1) Buildings adjacent to an alley when permitted in applicable zoning district; or (2) Windowless firewalls along other side or rear property lines for storefront buildings located on and complying with storefront or secondary block frontages. Such firewalls are limited in height to 25 feet. | 0' |
When required per subsection (3)(b) of this section for light and air access and privacy along the side and rear property lines. | 15' |
All other contexts (other than the two situations noted above) | 5' |
Figure 25.71.320(a) Light/Air Access and Privacy Standards for Multifamily Residential Buildings Along Interior Side and Rear Property Lines ![]() |
Table 25.71.320(b) Multifamily Amenity Space Types | |
|---|---|
Element Residential Amenity Space Types | Standards |
Common outdoor recreation areas See subsection (4)(e)(i) of this section | May be used for 100 percent of requirement |
Shared roof decks See subsection (4)(f)(i) of this section | May be used for up to 25 percent of requirement |
Private ground level open space See subsection (4)(f)(ii) of this section | May be used for 100 percent of requirement for applicable units |
Private balconies See subsection (4)(f)(iii) of this section | May be used for up to 25 percent of requirement |
Shared indoor recreation areas See subsection (4)(f)(iv) of this section | May be used for up to 25 percent of requirement |
Children’s play areas See subsection (4)(f)(v) of this section | Required for developments with more than 75 units. Not required for senior housing and other age-restricted facilities. |
Figure 25.71.320(b) Common Outdoor Recreation Area Examples ![]() Image A includes a combination of open lawn area for informal recreation plus walkways and decorative landscape areas to enhance the setting for residents. Image B includes a pond/wetland type area with a boardwalk. Image C includes a covered gathering space with outdoor grills adjacent to a landscaped commons with a central walkway. Image D includes a common green area with large trees. |
Figure 25.71.320(c) Children’s Play Area Example ![]() |
Figure 25.71.320(d) Good Commercial Open Space Examples ![]() |
Figure 25.71.320(e) Good Examples of Direct Pedestrian Access to Buildings From the Street ![]() |
Figure 25.71.320(f) Example Site Plan with Good Internal and External Pedestrian Connections ![]() |
Figure 25.71.320(g) Good Examples of Direct Walkways Between the Street and Dwelling Units ![]() |
Figure 25.71.320(h) Parking Lot Pedestrian Walkway Standards and Example ![]() Note the location of the parking lot walkway in the upper right example (connecting shops in one building to the main entry of a grocery store). |
Figure 25.71.320(i) Standards for Internal Walkways Adjacent to Buildings ![]() Internal walkways adjacent to building walls that do not meet storefront facade standards shall provide at least three feet of landscaping to enhance the character of the walkway. The reviewing authority will consider alternative treatments, such as decorative walls (right example). |
Figure 25.71.320(j) Acceptable Trash Screening Enclosures ![]() All examples use durable and attractive enclosures with trees and shrubs to soften views of the enclosures from the side. Images C and D use a trellis and weather protection structure on top – a desirable feature particularly where the tops of the enclosures are visible from surrounding buildings, streets, and walkways (due to topography or building heights). |
Figure 25.71.320(k) Utility Meter Location and Screening – Good and Bad Examples ![]() Place utility meters in less visible locations. Images A and C are successfully tucked away in a less visible location and/or screened by vegetation. Images B and D are poorly executed and would not be permitted in such visible locations. Such meters shall be coordinated and better integrated with the architecture of the building. |
Figure 25.71.320(l) Examples of How to Screen Roof-Mounted Mechanical Equipment ![]() The left illustration shows how rooftop mechanical equipment can be located and screened effectively. The right image shows effective location and screening, including side walls and a trellis to screen views from taller surrounding buildings. |
Figure 25.71.320(m) Examples of Site Lighting ![]() |
Figure 25.71.440(a) Nonresidential Articulation Examples ![]() The left image uses window patterns, weather protection elements, and roofline modulation. The photo example to the right also includes window patterns and weather protection along with a change in masonry texture and color to articulate the facade. The lower example illustrates how a multitenant retail building can successfully be articulated (windows, weather protection, vertical building modulation, and roofline changes). |
![]() |
Figure 25.71.440(c) Multifamily Roofline Articulation Examples ![]() |
Below Image A uses a combination of vertical building modulation, window patterns, material changes, and roofline modulation. Image B is unacceptable. ![]() |
![]() Roofline modulation qualifies as an articulation feature when combined with vertical building modulation techniques. |
![]() The left building illustrates a pitched roof example, and the right building illustrates a flat roof example. |
Figure 25.71.440(d) Illustrating Maximum Facade Width Standards and Good and Bad Examples | |
![]() Less than 120 feet wide: Meets standard. | ![]() More than 120 feet wide: Does not meet standard. |
![]() Building incorporates a courtyard along the facade (technique #1 noted above) to effectively break it up into smaller components: Meets standard. | |
![]() The left building uses technique # 1 (vertical building modulation at least six feet deep and 15 feet wide). The right building uses technique #2 (contrasting vertical modulated design component). Both examples are effective in breaking up the perceived scale of the building and adding visual interest. | |
Figure 25.71.450(a) Examples of Decorative or Specially Designed Windows and Entries ![]() Examples of decorative or specially designed windows and entries. A = openable storefront window. B = transom windows. C = openable window with decorative details. D = decorative window shades. E = decorative door. F = recessed entry. |
Figure 25.71.450(b) Examples of Decorative or Specially Designed Windows and Entries ![]() |
![]() |
Figure 25.71.450(c) Examples of Decorative Surface Materials ![]() |
![]() Examples of Decorative Surface Materials. A = decorative brick/design. B = decorative tile work and column pattern. C = decorative medallion. D = decorative mosaic tile work. E = decorative bulkhead. F = decorative materials and design. |
Figure 25.71.450(d) Acceptable and Unacceptable Window Design Examples ![]() The windows in Building A are recessed by at least one and one-half inches from the facade. Building B features trim at least three inches wide. Building C windows may not meet the full one and one-half inches recess, but the detailing adds a sense of depth and richness to the facade. Building D is not recessed, does not feature trim, and does not include any detailing. |
Figure 25.71.450(e) Examples of Buildings Employing Confident and Distinctive Rooflines ![]() |
Figure 25.71.450(f) Building Entry Examples ![]() |
Figure 25.71.460(a) Acceptable Concrete Block Use and Design ![]() Building A uses alternating rows of concrete block and brick as an effective and contrasting accent material for its podium structure. Building B uses CMU as the primary cladding material for the ground level. Note the use of split-facade CMUs above each of the awnings and coupled with the use of smooth-facade CMUs on the vertical columns (which employ black accent tiles for added interest). |
Figure 25.71.460(b) Acceptable Metal Siding Examples ![]() The buildings in Images A and B integrate a range of metal siding with masonry and other materials. |
Figure 25.71.460(c) Acceptable and Unacceptable Cementitious Wall Board Examples ![]() The building on the left uses cement board in different textures and colors to help articulate the facade. The white color replicates the board and batten style in the left image and green color in the middle image effectively replicates horizontal wood siding. The wall board panels covering a large area in a single color as in right image would not meet the purpose of the standards. |
Figure 25.71.470(a) Blank Wall Definition Within Five Feet of a Front Lot Line ![]() |
Figure 25.71.470(b) Blank Wall Treatment Examples ![]() |
![]() Image A uses an artistic mural; Image B uses a landscape planting bed; Image C uses a trellis with a vine plant; Image D uses an elevated planting bed and a trellis. |
Figure 25.71.550(a) Unit Density Examples ![]() |
Figure 25.71.570(a) Street Setback Standards for Individual/Private Garages on Small Single-Family Lots ![]() |
![]() |
![]() The examples above comply with the standard, as the garage doors are not placed in front of the dwelling (including covered porch or living areas above the garage). |
![]() These examples do not comply with the standard. On the left, there is a “dwelling” space above the garage but the garage extends out in front of it. On the right, the garage extends beyond the front door and living areas. |
Figure 25.71.580(a) Garage Design Detail Examples | |
|---|---|
![]() A decorative trellis over the garage door. | ![]() A balcony over the garage, single doors (instead of a wider double door), and windows above the garage on a second story. |
Table 25.71.580(a) Driveway Cut Width | ||
|---|---|---|
Lot Width | Minimum Driveway Width | Maximum Driveway Width |
≥ 40 feet | 10 feet | 20 feet |
< 40 feet | 10 feet | 12 feet |
Figure 25.71.580(b) Windows and Doors Transparency ![]() |