Building Type Standards
Size of Standard | |||||||
|---|---|---|---|---|---|---|---|
Narrow | Small | Medium | Large | Wide | XXL | ||
Lot Regulations | |||||||
A | Frontage width (feet) | Parcels up to 39.9 | 40 - 49.9 | 50 - 59.9 | 60 - 74.9 | 75 - 124.9 | 125+ |
B | Minimum lot depth (feet) | 80 | 80 | 80 | 80 | 80 | 80 |
C | Minimum lot size (square feet) | 2,400 | 3,200 | 4,000 | 4,800 | 6,000 | 12,500 |
Setbacks | |||||||
D | Build-to-line | See district standards in Part 2. | |||||
E | Minimum side yard (individual) (feet) | 2 | 3 | 5 | 5 | 5 | 20 |
Minimum side yard (total) (feet) | 10 | 13 | 18 | 18 | 18 | 45 | |
F | Minimum rear yard (feet) | 20 | 20 | 20 | 20 | 20 | 20 |
Coverage | |||||||
G | Maximum building coverage | 35% | 30% | 25% | 20% | 20% | 20% |
H | Maximum improved coverage | 45% | 40% | 35% | 30% | 30% | 30% |
Note: The width of the lot shall dictate the standards applicable to a given parcel (e.g., a forty-foot-wide parcel is considered "small" and thus all standards for a "small" lot shall be applicable). In cases of corner lots, the frontage width shall be considered the width of the lot line parallel to the front door facing a street. If frontage width on a corner lot cannot be determined based on unique site circumstance, the Zoning Officer shall make a determination. |
Size of Standard | ||||||||
|---|---|---|---|---|---|---|---|---|
Narrow | Small | Medium | Large | Wide | XXL | |||
Building Regulations | ||||||||
A | Maximum building width (feet) | 27 | 27 | 35 | 60 | 60 | 80 | |
B | Maximum building depth (feet) | 50 | 50 | 50 | 50 | 50 | 50 | |
C | Build-to-line occupancy C /A | |||||||
Minimum | 80% | 80% | 60% | 45% | 40% | 35% | ||
Maximum | 100% | 100% | 85% | 75% | 55% | 50% | ||
D | Main entrance | Front street | Front street | Front street | Front street | Front street | Front street | |
Size of Standard | |||
|---|---|---|---|
Applies to All Sizes | |||
Minimum | Maximum | ||
Main Body | |||
A | Building height (floors/feet) | See district standards in Part 2. | |
B | Ground floor height (floor to ceiling, feet) | 101 | — |
C | Upper floor height (floor to ceiling, feet) | 91 | — |
D | Finished floor elevation (inches) | See district standards in Part 2. | |
Massing and Composition | |||
E | Principal roof pitch (rise:run) | Flat or 4:12 | 18:12 |
Ancillary roof pitch | No greater than principal roof slope2 | ||
F | Horizontal articulation | N/A | |
G | Transparency, street facing facades | 25% | — |
H | Transparency, non-street-facing facades (if visible from right-of-way)3 | 25% | — |
Notes: | |
1 | Existing structures adding an addition may maintain the existing floor to ceiling height. |
2 | Pitched ancillary roofs are permitted on flat-roofed buildings, but must comply with principal roof pitch requirements. |
3 | No minimum value required where facade is located on a property line. See § 30-329 regarding treatment to blank walls. |
Size of Standard | |||
|---|---|---|---|
Applies To All Sizes | |||
Minimum | Maximum | ||
Lot | |||
A | Frontage width (feet) | 50 | — |
B | Lot depth (feet) | 100 | — |
C | Lot size (square feet) | 5,000 | — |
Setbacks | |||
D | Build-to-line | See district standards in Part 2. | |
E | Side yard (individual) (feet) | 10 | — |
Side yard (total) (feet) | 20 | — | |
F | Rear yard (feet) | 30 | — |
Coverage | |||
G | Building coverage1 | — | 20% |
H | Improved coverage | — | 30% |
Note: | |
1 | Maximum building coverage upon existing parcels that are less than 5,000 square feet may be increased to 25% building coverage. |
Size of Standard | |||
|---|---|---|---|
Applies to All Sizes | |||
Minimum | Maximum | ||
Main body | |||
A | Building height (floors/feet) | See district standards in Part 2. | |
B | Ground floor height (floor to ceiling, feet) | 101 | — |
C | Upper floor height (floor to ceiling, feet) | 91 | — |
D | Finished floor elevation (inches) | See district standards in Part 2. | |
Massing and Composition | |||
E | Principal roof pitch (rise:run) | 4:12 | 18:12 |
Ancillary roof pitch | No greater than principal roof slope2 | ||
F | Horizontal articulation | N/A | |
G | Transparency, street-facing facades | See frontage standards in Article 3C. | |
H | Transparency, non-street-facing facades (if visible from right-of-way)3 | 25% | — |
Notes: | |
1 | Existing structures adding an addition may maintain the existing floor to ceiling height. |
2 | Pitched ancillary roofs are permitted on flat-roofed buildings, but must comply with principal roof pitch requirements. |
3 | No minimum value required where facade is located on a property line. See § 30-329 regarding treatment of blank walls. |
Size of Standard | |||||||
|---|---|---|---|---|---|---|---|
Narrow | Small | Medium | Large | Wide | XXL | ||
Lot Regulations | |||||||
A | Frontage width (feet) | Parcels up to 39.9 | 40 - 49.9 | 50 - 59.9 | 60 - 74.9 | 75 - 124.9 | 125 + |
B | Minimum lot depth (feet) | 80 | 80 | 80 | 80 | 80 | 80 |
C | Minimum lot size (square feet) | 2,400 | 3,200 | 4,000 | 4,800 | 6,000 | 12,500 |
Setbacks | |||||||
D | Build-to-line | See building placement standards in your district: Part 2. | |||||
E | Minimum side yard (individual) (feet) | 1 | 3 | 5 | 5 | 5 | 20 |
Minimum side yard (total) (feet) | 8 | 13 | 18 | 18 | 18 | 45 | |
F | Minimum rear yard (feet) | 20 | 20 | 20 | 20 | 20 | 20 |
Coverage | |||||||
G | Maximum building coverage | 30% | 30% | 30% | 30% | 20% | 20% |
H | Maximum improved coverage | 40% | 40% | 40% | 40% | 30% | 30% |
Note: The width of the lot shall dictate the standards applicable to a given parcel (e.g., a forty-foot-wide parcel is considered "small" and thus all standards for a "small" lot shall be applicable). In cases of corner lots, the frontage width shall be considered the width of the lot line parallel to the front door facing a street. If frontage width on a corner lot cannot be determined based on unique site circumstance, the Zoning Officer shall make a determination. |
Size of Standard | ||||||||
|---|---|---|---|---|---|---|---|---|
Narrow | Small | Medium | Large | Wide | XXL | |||
Building | ||||||||
A | Maximum building width (feet) | 27 | 27 | 35 | 45 | 60 | 80 | |
B | Maximum building depth (feet) | 50 | 50 | 50 | 50 | 50 | 50 | |
C | Build-to-line occupancy C /A | Minimum | 80% | 80% | 60% | 45% | 40% | 35% |
Maximum | 100% | 100% | 85% | 75% | 55% | 50% | ||
D | Main entrance | Front street | Front street | Front street | Front street | Front street | Front street | |
Size of Standard | |||
|---|---|---|---|
Applies to All Sizes | |||
Minimum | Maximum | ||
Main Body | |||
A | Building height (floors/feet) | See district standards in Part 2. | |
B | Ground floor height (floor to ceiling, feet) | 101 | — |
C | Upper floor height (floor to ceiling, feet) | 91 | — |
D | Finished floor elevation (inches) | See District Standards in Sec. 30-2 | |
Massing and Composition | |||
E | Principal roof pitch (rise:run) | Flat or 4:12 | 18:12 |
Ancillary roof pitch | No greater than principal roof slope2 | ||
F | Horizontal articulation | N/A | |
G | Transparency, street-facing facades | 25% | — |
H | Transparency, non-street-facing facades (if visible from right-of-way)3 | 25% | |
Notes: | |
1 | Existing structures adding an addition may maintain the existing floor to ceiling height. |
2 | Pitched ancillary roofs are permitted on flat-roofed buildings, but must comply with principal roof pitch requirements |
3 | No minimum value required where facade is located on a property line. See § 30-329 regarding treatment of blank walls. |
Minimum | Maximum | ||
Lot Regulations | |||
A | Frontage width (feet) | 50 | — |
B | Minimum lot depth (feet) | 125 | — |
C | Minimum lot size (square feet) | 6,250 | — |
Setbacks | |||
D | Build-to-line1 | See district standards in Part 2. | |
E | Side yard (individual) | See Note2 | |
Side yard (total) | See Note2 | ||
F | Rear yard | See Note2 | |
Coverage | |||
G | Building coverage | — | 50% |
H | Improved coverage | — | 70% |
Notes: | |
1 | Applicable to the primary building only, unless the courtyard building is on a corner lot. |
2 | |
Minimum | Maximum | ||
General Building Standards | |||
A | Building width1 (feet) | — | 40 |
B | Building depth1 (feet) | — | 50 |
C | Build-to-line-occupancy C /A | See Note2 | |
D | Main entrance | See Note2 | |
E | Building separation (feet) | 24 | — |
Notes: | |
|---|---|
1 | |
2 | |
Minimum | Maximum | ||
|---|---|---|---|
Main Body | |||
A | Building height (stories/feet) | ||
Primary building | See district standards in Part 2. | ||
Courtyard building | 2.5/25 (maximum) | ||
B | Ground floor height (floor to ceiling, feet) | 9 | — |
C | Upper floor height (floor to ceiling, feet) | 8 | — |
D | Finished floor elevation1 | See district standards in Part 2. | |
Massing and Composition | |||
E | Roof pitch (rise:run) | See Note2 | |
Ancillary roof pitch | See Note2 | ||
F | Transparency, street-facing facades | See frontage standards in Part 3. | |
G | Transparency, non-street-facing facades (if visible from right-of-way)3 | 25% | N/A |
Notes: | |
|---|---|
1 | Finished floor elevation is applicable to the primary building only, unless the courtyard building is on a corner lot. |
2 | |
3 | No minimum value required where the façade is located on a property line. See § 30-329 regarding treatment of blank walls. |
Minimum | Maximum | ||
|---|---|---|---|
Interior Lot | |||
A | Frontage width (feet) | 120 | — |
B | Lot depth (feet) | 125 | — |
C | Lot size (square feet) | 12,500 | — |
Corner Lot | |||
D | Frontage width (feet) | 75 | — |
E | Lot depth (feet) | 115 | — |
F | Lot size (square feet) | 8,050 | — |
Setbacks: All Lots | |||
G | Build-to-line | See district standards in Part 2. | |
H | Side yard (individual) (feet) | 8 | |
Side yard (total) (feet) | 20 | ||
I | Rear yard (feet) | 30 | |
Coverage Interior Lot | |||
J | Building coverage | — | 50% |
K | Improved coverage | — | 80% |
Coverage: Corner Lot | |||
L | Building coverage | — | 50% |
M | Improvement coverage | — | 85% |
Minimum | Maximum | ||
|---|---|---|---|
Main Body | |||
A | Building height (floors/feet) | See district standards in Part 2. | |
B | Ground floor height (floor to ceiling, feet) | 10 | — |
C | Upper floor height (floor to ceiling, feet) | 9 | — |
D | Finished floor elevation (inches) | 18 | — |
Massing and Composition | |||
E | Principal roof pitch (rise:run) | Flat or 4:12 minimum 18:12 maximum | |
Ancillary roof pith | No greater than principal roof slope | ||
F | Horizontal articulation | See design standards in Subsection 30-328.2. | |
G | Transparency, street-facing facades | See frontage standards in Article 3C. | |
H | Transparency, non-street-facing facades2 | 25% | — |
Notes: | |
|---|---|
1 | Pitched ancillary roofs are permitted on flat-roofed buildings, but must comply with principal roof pitch requirements. |
2 | No minimum value required where a façade is located on a property line. See § 30-329 regarding treatment of blank walls. |
Minimum | Maximum | ||
|---|---|---|---|
Lot | |||
A | Frontage width (feet) | 100 | — |
B | Lot depth (feet) | 125 | — |
C | Lot size (square feet) | 12,500 | — |
Setbacks, Main Structure | |||
D | Build-to-line | See district standards in Part 2. | |
E | Side yard (individual) (feet) | 12 | — |
Side yard (total) (feet) | 30 | — | |
F | Rear yard (feet) | 30 | — |
Coverage | |||
G | Building coverage | — | 30% |
H | Improved coverage | — | 70% |
Minimum | Maximum | ||
|---|---|---|---|
Main Body | |||
A | Building height (floors/feet) | See district standards in Part 2. | |
B | Ground floor height (floor to ceiling, feet) | 10 | — |
C | Upper floor height (floor to ceiling, feet) | 9 | — |
D | Finished floor elevation (inches) | 18 | — |
Massing and Composition | |||
E | Principal roof pitch (rise:run) | Flat or 4:12 minimum 18:12 maximum | |
Ancillary roof pitch | No greater than principal roof slope | ||
F | Horizontal articulation | See design standards in Subsection 30-328.2. | |
G | Transparency, street-facing facades | See frontage standards in Article 3C. | |
H | Transparency, non-street-facing facades2 | 25% | — |
Notes: | |
|---|---|
1 | Pitched ancillary roofs are permitted on flat-roofed buildings, but must comply with principal roof pitch requirements. |
2 | No minimum value required where a façade is located on a property line. See § 30-329 regarding treatment of blank walls. |
Minimum | Maximum | ||
|---|---|---|---|
Lot | |||
A | Frontage width (feet) | 60 | 200 |
B | Lot depth (feet) | 80 | — |
C | Lot size (square feet) | 4,800 | — |
Setbacks, Principal Buildings | |||
D | Build-to-line | See district standards in Part 2. | |
E | Side yard (individual) (feet) | 15 | — |
Side yard (total) (feet) | 30 | — | |
F | Rear yard (feet) | 20 | — |
Coverage | |||
G | Building coverage | 30% | — |
H | Improved coverage | 85% | — |
Minimum | Maximum | ||
|---|---|---|---|
Main Body | |||
A | Building height (floors/feet) | See district standards in Part 2. | |
B | Ground floor height (floor to ceiling, feet) | 12 | — |
C | Upper floor height (floor to ceiling, feet) | 9 | — |
D | Finished floor elevation (inches) | 0 | — |
Massing and Composition | |||
E | Principal roof pitch (rise:run) | — | 3:12 |
Ancillary roof pitch | No greater than principal roof slope | ||
F | Horizontal articulation | See design standards in Subsection 30-328.2. | |
G | Transparency, street-facing facades | See frontage standards in Article 3C. | |
H | Transparency, non-street-facing facades2 | 40% | 75% |
Notes: | |
|---|---|
1 | Pitched ancillary roofs are permitted on flat-roofed buildings, but must comply with principal roof pitch requirements. |
2 | No minimum value required where facade is located on a property line. See § 30-329 regarding treatment of blank walls. |
Minimum | Maximum | ||
|---|---|---|---|
Lot | |||
A | Frontage width (feet) | 200 | — |
B | Lot depth (feet) | 200 | — |
C | Lot size (square feet) | 40,000 | — |
Setbacks, Principal Building | |||
D | Build-to-line setback | See district standards in Part 2. | |
E | Side yard (individual)(feet) | 20 | — |
Side yard (total) (feet) | 40 | — | |
F | Rear yard (feet) | 20 | — |
Coverage | |||
G | Building coverage | — | 35% |
H | Improved coverage | — | 85% |
Minimum | Maximum | ||
|---|---|---|---|
Main Body | |||
A | Building height (floors/feet) | See district standards in Part 2. | |
B | Ground floor height (floor to ceiling, feet) | 12 | — |
C | Upper floor height (floor to ceiling, feet) | 9 | — |
D | Finished floor elevation (inches) | 0 | — |
Massing and Composition | |||
E | Principal roof pitch (rise:run) | — | 3:12 |
Ancillary roof pitch | No greater than principal roof slope | ||
F | Horizontal articulation | See design standards in Subsection 30-328.2. | |
G | Transparency, street-facing facades | See frontage standards in Article 3C. | |
H | Transparency, non-street-facing facades2 | 20% | 75% |
Notes: | |
|---|---|
1 | Pitched ancillary roofs are permitted on flat-roofed buildings, but must comply with principal roof pitch requirements. |
2 | No minimum value required where facade is located on a property line. See § 30-329 regarding treatment of blank walls. |
Minimum | Maximum | ||
|---|---|---|---|
Lot | |||
A | Frontage width (feet) | 140 | — |
B | Lot depth (feet) | 125 | — |
C | Lot size (square feet) | 17,500 | — |
D | Building coverage | — | 30%1 |
E | Improved coverage | 85%1 | |
Setbacks, Principal Buildings | |||
F | Build-to-line | See district standards in Part 2. | |
G | Side yard (individual) (feet) | 10 | — |
Side yard (total) (feet) | 50 | — | |
H | Rear yard (feet) | 25 | — |
Note: | |
1 | Building coverage of up to 50% is permitted so long as overall lot coverage does not exceed 60%. |
Size of Standard | |||
|---|---|---|---|
Applies to All Sizes | |||
Minimum | Maximum | ||
Main Body | |||
A | Building height (floors/feet) | See district standards in Part 2. | |
B | Ground floor height (floor to ceiling, feet) | 12 | — |
C | Upper floor height (floor to ceiling, feet) | 9 | — |
D | Finished floor elevation (inches) | 0 | — |
Massing and Composition | |||
E | Principal roof pitch (rise:run) | — | 3:12 |
Ancillary roof pitch | No greater than principal roof | ||
F | Horizontal articulation | See design standards in Subsection 30-328.2. | |
G | Transparency, street-facing facades | See frontage standards in Article 3C. | |
H | Transparency, non-street-facing facades2 | 40% | 75% |
Notes: | |
|---|---|
1 | Pitched ancillary roofs are permitted on flat-roofed buildings, but must comply with principal roof pitch requirements. |
2 | No minimum value required where a façade is located on a property line. See § 30-329 regarding treatment of blank walls. |
Minimum | Maximum | ||
|---|---|---|---|
Lot | |||
A | Frontage width (feet) | 100 | — |
B | Lot depth (feet) | 125 | — |
C | Lot size (square feet) | 30,000 | — |
Setbacks, Buildings | |||
D | Build-to-line setback | See district standards in Part 2. | |
E | Minimum side yard (individual) (feet) | 0 or 15 | 35 |
F | Rear yard (feet) | 20 | — |
Coverage | |||
G | Building coverage | — | 70% |
H | Improved coverage | — | 95% |
I | Floor area ratio1 | — | 2.74 |
Note: | |
1 | Excluding structured parking |
Minimum | Maximum | ||
|---|---|---|---|
Main Body | |||
A | Building height (floors/feet) | See district standards in Part 2. | |
B | Ground floor height (floor to ceiling, feet) | 12 | — |
C | Upper floor height (floor to ceiling, feet) | 9 | — |
D | Finished floor elevation (inches) | 0 | |
Massing and Composition | |||
E | Principal roof pitch (rise:run) | — | 3:12 |
Accessory roof pitch | No greater than principal roof | ||
F | Horizontal articulation | See design standards in Subsection 30-328.2. | |
G | Transparency, street-facing facades | See frontage standards in Article 3C. | |
H | Transparency, non-street-facing facades1 | 25% | 75% |
Note: | |
1 | No minimum value required where a façade is located on a property line. See § 30-329 regarding treatment of blank walls. |
Minimum | Maximum | ||
|---|---|---|---|
Lot | |||
A | Frontage width (feet) | 25 | 75 |
B | Lot depth (feet) | 65 | — |
C | Lot size (square feet) | 1,625 | — |
Setbacks, Principal Buildings | |||
D | Build-to-line | See district standards in Part 2. | |
E | Side yard (individual) (feet) | 0 or 15 | 35 |
F | Rear yard (feet) | 20 | — |
Coverage, Principal Buildings | |||
G | Building coverage | — | 85% |
H | Improved coverage | — | 85%1 |
Note: | |
1 | Urban, small buildings in the TC District may be permitted up to 95% improved coverage. |
Minimum | Maximum | ||
|---|---|---|---|
Building | |||
A | Building width | N/A | N/A |
B | Building depth | N/A | N/A |
C | Build-to-line occupancy C /A | 95% | — |
D | Main entrance | Front | |
E | Driveway width (feet) | N/A | 24 |
F | Distance between entrances1 (feet) | — | 40 |
Parking | |||
G | Mid-block connection width (when provided) (feet) | 18 | N/A |
Note: | |
1 | This standard shall be excluded insofar as deviation would require conformance with FAR limitations as may be imposed pursuant to district standards. |
Minimum | Maximum | ||
|---|---|---|---|
Main Body | |||
A | Building height (floors/feet) | See district standards in Part 2. | |
B | Ground floor height (floor to ceiling, feet) | 12 | — |
C | Upper floor height (floor to ceiling, feet) | 9 | — |
D | Finished floor elevation (inches) | — | 0 |
Massing and Composition | |||
E | Principal roof pitch (rise:run) | — | 3:12 |
Ancillary roof pitch | No greater than principal roof | ||
F | Horizontal articulation | See design standards in Subsection 30-328.2. | |
G | Transparency, street-facing facades | See frontage standards in Article 3C. | |
H | Transparency, non-street-facing facades3 | 30% | 75%2 |
Notes: | |
|---|---|
1 | Pitched ancillary roofs are permitted on flat-roofed buildings, but must comply with principal roof pitch requirements. |
2 | Minimum and maximum transparency standards do not apply to buildings with a side yard setback of zero feet. |
3 | No minimum value required where facade is located on a property line. See § 30-329 regarding treatment of blank walls. |
Minimum | Maximum | ||
|---|---|---|---|
Lot | |||
A | Frontage width (feet) | 75 | 250 |
B | Lot depth (feet) | 100 | — |
C | Lot size (square feet) | 7,000 | — |
Setbacks, Buildings | |||
D | Build-to-line setback | See district standards in Part 2. | |
E | Side yard (individual) (feet) | 0 or 15 | 35 |
F | Rear yard (feet) | 20 | — |
Coverage, Buildings | |||
G | Building coverage | — | 85% |
H | Improved coverage | — | 95% |
Minimum | Maximum | ||
|---|---|---|---|
Building | |||
A | Building width (feet) | N/A | 250 |
B | Building depth | N/A | N/A |
C | Build-to-line occupancy C /A | 95% | — |
D | Main entrance | Front | |
E | Driveway width (feet) | N/A | 24 |
F | Distance between entrances1 (feet) | N/A | 40 |
Parking | |||
G | Mid-block connection width (when provided) (feet) | 18 | N/A |
Note: | |
1 | This standard shall be excluded insofar as deviation would require conformance with FAR limitations as may be imposed pursuant to district standards. |
Minimum | Maximum | ||
|---|---|---|---|
Main Body | |||
A | Building height (floors/feet) | See district standards in Part 2. | |
B | Ground floor height (floor to ceiling, feet) | 12 | — |
C | Upper floor height (floor to ceiling, feet) | 9 | — |
D | Finished floor elevation (inches) | — | 0 |
Massing and Composition | |||
E | Principal roof pitch (rise:run) | — | 3:12 |
Accessory roof pitch | No greater than principal roof | ||
F | Horizontal articulation | See design standards in Subsection 30-328.2. | |
G | Transparency, street-facing facades | See frontage standards in Article 3C. | |
H | Transparency, non-street-facing facades3 | 40% | 75%2 |
Notes: | |
1 | Pitched ancillary roofs are permitted on flat-roofed buildings, but must comply with principal roof pitch requirements. |
2 | Minimum and maximum transparency standards do not apply to buildings with a side yard setback of zero feet. |
3 | No minimum value required where facade is located on a property line. See § 30-329 regarding treatment of blank walls. |
Regulation | Minimum | Maximum | |
i. | Active ground floor use required | Yes | |
ii. | Transparency, ground floor | 60% | 80% |
iii. | Transparency, upper floors | 30% | 70% |
iv. | Build-to-line | See district standards. | |
v. | Encroachments (feet) | — | 10 |
vi. | Step back required (stories/feet) | 4/42 | 4/53 |
vii. | Step back requirement | 12.5% of building depth, minimum 10 feet and maximum 20 feet | |
Key: |
P: Permitted |
NP: Not permitted |
Building Elements | Permission |
|---|---|
Balcony | NP |
Bay window | P |
Porches | NP |
Stoops | NP |
Terraces | P |
Awnings | P |
Lobby | P |
Porte cocheres | NP |
Attached side garages | NP |
Note: |
See § 30-333 for regulations regarding building elements. |
Regulation | Minimum | Maximum | |
|---|---|---|---|
i. | Active ground floor use required | Yes | |
ii. | Transparency, ground floor | 60% | 80% |
iii. | Transparency, upper floors | 30% | 70% |
iv. | Build-to-line | See district standards. | |
v. | Encroachments (feet) | — | 10 |
vi. | Step back required (stories/feet) | 4/42 | 4/53 |
vii. | Step back requirement | 12.5% of building depth, minimum 10 feet and maximum 20 feet | |
Key: |
P: Permitted |
NP: Not permitted |
Building Elements | Permission |
|---|---|
Balcony | NP |
Bay window | P |
Porches | NP |
Stoops | NP |
Terraces | P |
Awnings | P |
Lobby | P |
Porte cocheres | NP |
Attached side garages | NP |
Note: |
See § 30-333 for regulations regarding building elements. |
Regulation | Minimum | Maximum | |
|---|---|---|---|
i. | Active ground floor use required | No | |
ii. | Transparency, ground floor | 30% | — |
iii. | Transparency, upper floors | 25% | — |
iv. | Build-to-line | See district standards. | |
v. | Encroachments past build-to-line (feet) | — | 10 |
vi. | Step back required (stories/feet) | 4/42 | 4/53 |
vii. | Step back requirement | 12.5% of building depth, minimum 10 feet and maximum 20 feet | |
Key: |
P: Permitted |
NP: Not permitted |
Building Elements | Permission |
|---|---|
Balcony | P |
Bay window | P |
Porches | NP |
Stoops | NP |
Terraces | P |
Awnings | P |
Lobby | P |
Porte cocheres | NP |
Attached side garages | NP |
Note: |
See § 30-333 for regulations regarding building elements. |
Regulation | Minimum | Maximum | |
|---|---|---|---|
i. | Active ground floor use required | No | |
ii. | Transparency, ground floor | 30% | 80% |
iii. | Transparency, upper floors | 25% | — |
iv. | Build-to-line | See district standards. | |
v. | Encroachments | — | 10 |
vi. | Step back required (stories/feet) | 2/28 | 3/41 |
vii. | Step back requirement | 12.5% of building depth, minimum 10 feet and maximum 20 feet | |
Key: |
P: Permitted |
NP: Not permitted |
Building Elements | Permission |
|---|---|
Balcony | P |
Bay window | P |
Porches | NP |
Stoops | P |
Terraces | P |
Awnings | P |
Lobby | P |
Porte cocheres | NP |
Attached side garages | NP |
Note: |
See § 30-333 for regulations regarding building elements. |
Regulation | Minimum | Maximum | |
|---|---|---|---|
i. | Active ground floor use required | No | |
ii. | Transparency, ground floor | 25% | — |
iii. | Transparency, upper floors | 20% | — |
iv. | Build-to-line | See district standards. | |
v. | Encroachments (feet) | — | 10 |
vi. | Step back required (stories/feet) | 4/42 | 4/53 |
vii. | Step back requirement | 12.5% of building depth, minimum 10 feet and maximum 20 feet | |
Key: |
P: Permitted |
NP: Not permitted |
Building Elements | Permission |
|---|---|
Balcony | P |
Bay window | P |
Porches | P |
Stoops | P |
Terraces | P |
Awnings | P |
Lobby | P |
Porte cocheres | NP |
Attached side garages | NP |
Note: |
See § 30-333 for regulations regarding building elements. |
Regulation | Minimum | Maximum | |
|---|---|---|---|
i. | Active ground floor use required | No | |
ii. | Transparency, ground floor | 35% | 75% |
iii. | Transparency, upper floors | 20% | — |
iv. | Build-to-line | See district standards. | |
v. | Encroachments (feet) | — | 10 |
vi. | Step back required (stories/feet) | 4/42 | 4/53 |
vii. | Step back requirement | 12.5% of building depth, minimum 10 feet and maximum 20 feet | |
Key: |
P: Permitted |
NP: Not permitted |
Building Elements | Permission |
|---|---|
Balcony | P |
Bay window | P |
Porches | P |
Stoops | P |
Terraces | P |
Awnings | P |
Lobby | P |
Porte cocheres | NP |
Attached side garages | NP |
Note: |
See § 30-333 for regulations regarding building elements. |
Key: |
P: Permitted |
NP: Not permitted |
Building Elements | Permission |
|---|---|
Balcony | P |
Bay window | P |
Porches | NP |
Stoops | NP |
Terraces | P |
Awnings | P |
Lobby | P |
Porte cocheres | NP |
Attached side garages | NP |
Note: |
See § 30-333 for regulations regarding building elements. |
Regulation | Minimum | Maximum | |
|---|---|---|---|
i. | Active ground floor use required | No | |
ii. | Transparency, ground floor | 25% | — |
iii. | Transparency, upper floors | 20% | — |
iv. | Build-to-line | See district standards. | |
v. | Encroachments (feet) | — | 10 |
vi. | Step back required (stories/feet) | — | 3/41 |
vii. | Step back requirement | 12.5% of building depth, minimum 10 feet and maximum 20 feet | |
Key: |
P: Permitted |
NP: Not permitted |
Building Elements | Permission |
|---|---|
Balcony | P |
Bay window | P |
Porches | P |
Stoops | P |
Terraces | P |
Awnings | NP |
Lobby | NP |
Porte cocheres | NP |
Attached side garages | P |
Note: |
See § 30-333 for regulations regarding building elements. |
Regulation | Minimum | Maximum | |
|---|---|---|---|
i. | Active ground floor use required | No | |
ii. | Transparency, ground floor | 25% | — |
iii. | Transparency, upper floors | 20% | — |
iv. | Build-to-line | See district standards. | |
v. | Encroachments (feet) | — | 10 |
vi. | Step back required (stories/feet) | — | 3/41 |
vii. | Step back requirement | 12.5% of building depth, minimum 10 feet and maximum 20 feet | |
Key: |
P: Permitted |
NP: Not permitted |
Building Elements | Permission |
|---|---|
Balcony | P |
Bay window | P |
Porches | P |
Stoops | P |
Terraces | P |
Awnings | NP |
Lobby | NP |
Porte cocheres | NP |
Attached side garages | NP |
Note: |
See § 30-333 for regulations regarding building elements. |
Regulation | Minimum | Maximum | |
|---|---|---|---|
i. | Active ground floor use required | No | |
ii. | Transparency, ground floor | 25% | — |
iii. | Transparency, upper floors | 20% | — |
iv. | Build-to-line | See district standards. | |
v. | Encroachments (feet) | — | 10 |
vi. | Step back required (stories/feet) | — | 3/41 |
vii. | Step back requirement | 12.5% of building depth, minimum 10 feet and maximum 20 feet | |
Key: |
P: Permitted |
NP: Not permitted |
Building Elements | Permission |
|---|---|
Balcony | P |
Bay window | P |
Porches | P |
Stoops | P |
Terraces | P |
Awnings | NP |
Lobby | NP |
Porte cocheres | NP |
Attached side garages | NP |
Note: |
See § 30-333 for regulations regarding building elements. |
Key: |
P: Permitted |
NP: Not permitted |
Building Elements | Permission |
|---|---|
Balcony | P |
Bay window | P |
Porches | P |
Stoops | P |
Terraces | P |
Awnings | NP |
Lobby | NP |
Porte cocheres | P |
Attached side garages | NP |
Note: |
See § 30-333 for regulations regarding building elements. |
Building Type Standards
Size of Standard | |||||||
|---|---|---|---|---|---|---|---|
Narrow | Small | Medium | Large | Wide | XXL | ||
Lot Regulations | |||||||
A | Frontage width (feet) | Parcels up to 39.9 | 40 - 49.9 | 50 - 59.9 | 60 - 74.9 | 75 - 124.9 | 125+ |
B | Minimum lot depth (feet) | 80 | 80 | 80 | 80 | 80 | 80 |
C | Minimum lot size (square feet) | 2,400 | 3,200 | 4,000 | 4,800 | 6,000 | 12,500 |
Setbacks | |||||||
D | Build-to-line | See district standards in Part 2. | |||||
E | Minimum side yard (individual) (feet) | 2 | 3 | 5 | 5 | 5 | 20 |
Minimum side yard (total) (feet) | 10 | 13 | 18 | 18 | 18 | 45 | |
F | Minimum rear yard (feet) | 20 | 20 | 20 | 20 | 20 | 20 |
Coverage | |||||||
G | Maximum building coverage | 35% | 30% | 25% | 20% | 20% | 20% |
H | Maximum improved coverage | 45% | 40% | 35% | 30% | 30% | 30% |
Note: The width of the lot shall dictate the standards applicable to a given parcel (e.g., a forty-foot-wide parcel is considered "small" and thus all standards for a "small" lot shall be applicable). In cases of corner lots, the frontage width shall be considered the width of the lot line parallel to the front door facing a street. If frontage width on a corner lot cannot be determined based on unique site circumstance, the Zoning Officer shall make a determination. |
Size of Standard | ||||||||
|---|---|---|---|---|---|---|---|---|
Narrow | Small | Medium | Large | Wide | XXL | |||
Building Regulations | ||||||||
A | Maximum building width (feet) | 27 | 27 | 35 | 60 | 60 | 80 | |
B | Maximum building depth (feet) | 50 | 50 | 50 | 50 | 50 | 50 | |
C | Build-to-line occupancy C /A | |||||||
Minimum | 80% | 80% | 60% | 45% | 40% | 35% | ||
Maximum | 100% | 100% | 85% | 75% | 55% | 50% | ||
D | Main entrance | Front street | Front street | Front street | Front street | Front street | Front street | |
Size of Standard | |||
|---|---|---|---|
Applies to All Sizes | |||
Minimum | Maximum | ||
Main Body | |||
A | Building height (floors/feet) | See district standards in Part 2. | |
B | Ground floor height (floor to ceiling, feet) | 101 | — |
C | Upper floor height (floor to ceiling, feet) | 91 | — |
D | Finished floor elevation (inches) | See district standards in Part 2. | |
Massing and Composition | |||
E | Principal roof pitch (rise:run) | Flat or 4:12 | 18:12 |
Ancillary roof pitch | No greater than principal roof slope2 | ||
F | Horizontal articulation | N/A | |
G | Transparency, street facing facades | 25% | — |
H | Transparency, non-street-facing facades (if visible from right-of-way)3 | 25% | — |
Notes: | |
1 | Existing structures adding an addition may maintain the existing floor to ceiling height. |
2 | Pitched ancillary roofs are permitted on flat-roofed buildings, but must comply with principal roof pitch requirements. |
3 | No minimum value required where facade is located on a property line. See § 30-329 regarding treatment to blank walls. |
Size of Standard | |||
|---|---|---|---|
Applies To All Sizes | |||
Minimum | Maximum | ||
Lot | |||
A | Frontage width (feet) | 50 | — |
B | Lot depth (feet) | 100 | — |
C | Lot size (square feet) | 5,000 | — |
Setbacks | |||
D | Build-to-line | See district standards in Part 2. | |
E | Side yard (individual) (feet) | 10 | — |
Side yard (total) (feet) | 20 | — | |
F | Rear yard (feet) | 30 | — |
Coverage | |||
G | Building coverage1 | — | 20% |
H | Improved coverage | — | 30% |
Note: | |
1 | Maximum building coverage upon existing parcels that are less than 5,000 square feet may be increased to 25% building coverage. |
Size of Standard | |||
|---|---|---|---|
Applies to All Sizes | |||
Minimum | Maximum | ||
Main body | |||
A | Building height (floors/feet) | See district standards in Part 2. | |
B | Ground floor height (floor to ceiling, feet) | 101 | — |
C | Upper floor height (floor to ceiling, feet) | 91 | — |
D | Finished floor elevation (inches) | See district standards in Part 2. | |
Massing and Composition | |||
E | Principal roof pitch (rise:run) | 4:12 | 18:12 |
Ancillary roof pitch | No greater than principal roof slope2 | ||
F | Horizontal articulation | N/A | |
G | Transparency, street-facing facades | See frontage standards in Article 3C. | |
H | Transparency, non-street-facing facades (if visible from right-of-way)3 | 25% | — |
Notes: | |
1 | Existing structures adding an addition may maintain the existing floor to ceiling height. |
2 | Pitched ancillary roofs are permitted on flat-roofed buildings, but must comply with principal roof pitch requirements. |
3 | No minimum value required where facade is located on a property line. See § 30-329 regarding treatment of blank walls. |
Size of Standard | |||||||
|---|---|---|---|---|---|---|---|
Narrow | Small | Medium | Large | Wide | XXL | ||
Lot Regulations | |||||||
A | Frontage width (feet) | Parcels up to 39.9 | 40 - 49.9 | 50 - 59.9 | 60 - 74.9 | 75 - 124.9 | 125 + |
B | Minimum lot depth (feet) | 80 | 80 | 80 | 80 | 80 | 80 |
C | Minimum lot size (square feet) | 2,400 | 3,200 | 4,000 | 4,800 | 6,000 | 12,500 |
Setbacks | |||||||
D | Build-to-line | See building placement standards in your district: Part 2. | |||||
E | Minimum side yard (individual) (feet) | 1 | 3 | 5 | 5 | 5 | 20 |
Minimum side yard (total) (feet) | 8 | 13 | 18 | 18 | 18 | 45 | |
F | Minimum rear yard (feet) | 20 | 20 | 20 | 20 | 20 | 20 |
Coverage | |||||||
G | Maximum building coverage | 30% | 30% | 30% | 30% | 20% | 20% |
H | Maximum improved coverage | 40% | 40% | 40% | 40% | 30% | 30% |
Note: The width of the lot shall dictate the standards applicable to a given parcel (e.g., a forty-foot-wide parcel is considered "small" and thus all standards for a "small" lot shall be applicable). In cases of corner lots, the frontage width shall be considered the width of the lot line parallel to the front door facing a street. If frontage width on a corner lot cannot be determined based on unique site circumstance, the Zoning Officer shall make a determination. |
Size of Standard | ||||||||
|---|---|---|---|---|---|---|---|---|
Narrow | Small | Medium | Large | Wide | XXL | |||
Building | ||||||||
A | Maximum building width (feet) | 27 | 27 | 35 | 45 | 60 | 80 | |
B | Maximum building depth (feet) | 50 | 50 | 50 | 50 | 50 | 50 | |
C | Build-to-line occupancy C /A | Minimum | 80% | 80% | 60% | 45% | 40% | 35% |
Maximum | 100% | 100% | 85% | 75% | 55% | 50% | ||
D | Main entrance | Front street | Front street | Front street | Front street | Front street | Front street | |
Size of Standard | |||
|---|---|---|---|
Applies to All Sizes | |||
Minimum | Maximum | ||
Main Body | |||
A | Building height (floors/feet) | See district standards in Part 2. | |
B | Ground floor height (floor to ceiling, feet) | 101 | — |
C | Upper floor height (floor to ceiling, feet) | 91 | — |
D | Finished floor elevation (inches) | See District Standards in Sec. 30-2 | |
Massing and Composition | |||
E | Principal roof pitch (rise:run) | Flat or 4:12 | 18:12 |
Ancillary roof pitch | No greater than principal roof slope2 | ||
F | Horizontal articulation | N/A | |
G | Transparency, street-facing facades | 25% | — |
H | Transparency, non-street-facing facades (if visible from right-of-way)3 | 25% | |
Notes: | |
1 | Existing structures adding an addition may maintain the existing floor to ceiling height. |
2 | Pitched ancillary roofs are permitted on flat-roofed buildings, but must comply with principal roof pitch requirements |
3 | No minimum value required where facade is located on a property line. See § 30-329 regarding treatment of blank walls. |
Minimum | Maximum | ||
Lot Regulations | |||
A | Frontage width (feet) | 50 | — |
B | Minimum lot depth (feet) | 125 | — |
C | Minimum lot size (square feet) | 6,250 | — |
Setbacks | |||
D | Build-to-line1 | See district standards in Part 2. | |
E | Side yard (individual) | See Note2 | |
Side yard (total) | See Note2 | ||
F | Rear yard | See Note2 | |
Coverage | |||
G | Building coverage | — | 50% |
H | Improved coverage | — | 70% |
Notes: | |
1 | Applicable to the primary building only, unless the courtyard building is on a corner lot. |
2 | |
Minimum | Maximum | ||
General Building Standards | |||
A | Building width1 (feet) | — | 40 |
B | Building depth1 (feet) | — | 50 |
C | Build-to-line-occupancy C /A | See Note2 | |
D | Main entrance | See Note2 | |
E | Building separation (feet) | 24 | — |
Notes: | |
|---|---|
1 | |
2 | |
Minimum | Maximum | ||
|---|---|---|---|
Main Body | |||
A | Building height (stories/feet) | ||
Primary building | See district standards in Part 2. | ||
Courtyard building | 2.5/25 (maximum) | ||
B | Ground floor height (floor to ceiling, feet) | 9 | — |
C | Upper floor height (floor to ceiling, feet) | 8 | — |
D | Finished floor elevation1 | See district standards in Part 2. | |
Massing and Composition | |||
E | Roof pitch (rise:run) | See Note2 | |
Ancillary roof pitch | See Note2 | ||
F | Transparency, street-facing facades | See frontage standards in Part 3. | |
G | Transparency, non-street-facing facades (if visible from right-of-way)3 | 25% | N/A |
Notes: | |
|---|---|
1 | Finished floor elevation is applicable to the primary building only, unless the courtyard building is on a corner lot. |
2 | |
3 | No minimum value required where the façade is located on a property line. See § 30-329 regarding treatment of blank walls. |
Minimum | Maximum | ||
|---|---|---|---|
Interior Lot | |||
A | Frontage width (feet) | 120 | — |
B | Lot depth (feet) | 125 | — |
C | Lot size (square feet) | 12,500 | — |
Corner Lot | |||
D | Frontage width (feet) | 75 | — |
E | Lot depth (feet) | 115 | — |
F | Lot size (square feet) | 8,050 | — |
Setbacks: All Lots | |||
G | Build-to-line | See district standards in Part 2. | |
H | Side yard (individual) (feet) | 8 | |
Side yard (total) (feet) | 20 | ||
I | Rear yard (feet) | 30 | |
Coverage Interior Lot | |||
J | Building coverage | — | 50% |
K | Improved coverage | — | 80% |
Coverage: Corner Lot | |||
L | Building coverage | — | 50% |
M | Improvement coverage | — | 85% |
Minimum | Maximum | ||
|---|---|---|---|
Main Body | |||
A | Building height (floors/feet) | See district standards in Part 2. | |
B | Ground floor height (floor to ceiling, feet) | 10 | — |
C | Upper floor height (floor to ceiling, feet) | 9 | — |
D | Finished floor elevation (inches) | 18 | — |
Massing and Composition | |||
E | Principal roof pitch (rise:run) | Flat or 4:12 minimum 18:12 maximum | |
Ancillary roof pith | No greater than principal roof slope | ||
F | Horizontal articulation | See design standards in Subsection 30-328.2. | |
G | Transparency, street-facing facades | See frontage standards in Article 3C. | |
H | Transparency, non-street-facing facades2 | 25% | — |
Notes: | |
|---|---|
1 | Pitched ancillary roofs are permitted on flat-roofed buildings, but must comply with principal roof pitch requirements. |
2 | No minimum value required where a façade is located on a property line. See § 30-329 regarding treatment of blank walls. |
Minimum | Maximum | ||
|---|---|---|---|
Lot | |||
A | Frontage width (feet) | 100 | — |
B | Lot depth (feet) | 125 | — |
C | Lot size (square feet) | 12,500 | — |
Setbacks, Main Structure | |||
D | Build-to-line | See district standards in Part 2. | |
E | Side yard (individual) (feet) | 12 | — |
Side yard (total) (feet) | 30 | — | |
F | Rear yard (feet) | 30 | — |
Coverage | |||
G | Building coverage | — | 30% |
H | Improved coverage | — | 70% |
Minimum | Maximum | ||
|---|---|---|---|
Main Body | |||
A | Building height (floors/feet) | See district standards in Part 2. | |
B | Ground floor height (floor to ceiling, feet) | 10 | — |
C | Upper floor height (floor to ceiling, feet) | 9 | — |
D | Finished floor elevation (inches) | 18 | — |
Massing and Composition | |||
E | Principal roof pitch (rise:run) | Flat or 4:12 minimum 18:12 maximum | |
Ancillary roof pitch | No greater than principal roof slope | ||
F | Horizontal articulation | See design standards in Subsection 30-328.2. | |
G | Transparency, street-facing facades | See frontage standards in Article 3C. | |
H | Transparency, non-street-facing facades2 | 25% | — |
Notes: | |
|---|---|
1 | Pitched ancillary roofs are permitted on flat-roofed buildings, but must comply with principal roof pitch requirements. |
2 | No minimum value required where a façade is located on a property line. See § 30-329 regarding treatment of blank walls. |
Minimum | Maximum | ||
|---|---|---|---|
Lot | |||
A | Frontage width (feet) | 60 | 200 |
B | Lot depth (feet) | 80 | — |
C | Lot size (square feet) | 4,800 | — |
Setbacks, Principal Buildings | |||
D | Build-to-line | See district standards in Part 2. | |
E | Side yard (individual) (feet) | 15 | — |
Side yard (total) (feet) | 30 | — | |
F | Rear yard (feet) | 20 | — |
Coverage | |||
G | Building coverage | 30% | — |
H | Improved coverage | 85% | — |
Minimum | Maximum | ||
|---|---|---|---|
Main Body | |||
A | Building height (floors/feet) | See district standards in Part 2. | |
B | Ground floor height (floor to ceiling, feet) | 12 | — |
C | Upper floor height (floor to ceiling, feet) | 9 | — |
D | Finished floor elevation (inches) | 0 | — |
Massing and Composition | |||
E | Principal roof pitch (rise:run) | — | 3:12 |
Ancillary roof pitch | No greater than principal roof slope | ||
F | Horizontal articulation | See design standards in Subsection 30-328.2. | |
G | Transparency, street-facing facades | See frontage standards in Article 3C. | |
H | Transparency, non-street-facing facades2 | 40% | 75% |
Notes: | |
|---|---|
1 | Pitched ancillary roofs are permitted on flat-roofed buildings, but must comply with principal roof pitch requirements. |
2 | No minimum value required where facade is located on a property line. See § 30-329 regarding treatment of blank walls. |
Minimum | Maximum | ||
|---|---|---|---|
Lot | |||
A | Frontage width (feet) | 200 | — |
B | Lot depth (feet) | 200 | — |
C | Lot size (square feet) | 40,000 | — |
Setbacks, Principal Building | |||
D | Build-to-line setback | See district standards in Part 2. | |
E | Side yard (individual)(feet) | 20 | — |
Side yard (total) (feet) | 40 | — | |
F | Rear yard (feet) | 20 | — |
Coverage | |||
G | Building coverage | — | 35% |
H | Improved coverage | — | 85% |
Minimum | Maximum | ||
|---|---|---|---|
Main Body | |||
A | Building height (floors/feet) | See district standards in Part 2. | |
B | Ground floor height (floor to ceiling, feet) | 12 | — |
C | Upper floor height (floor to ceiling, feet) | 9 | — |
D | Finished floor elevation (inches) | 0 | — |
Massing and Composition | |||
E | Principal roof pitch (rise:run) | — | 3:12 |
Ancillary roof pitch | No greater than principal roof slope | ||
F | Horizontal articulation | See design standards in Subsection 30-328.2. | |
G | Transparency, street-facing facades | See frontage standards in Article 3C. | |
H | Transparency, non-street-facing facades2 | 20% | 75% |
Notes: | |
|---|---|
1 | Pitched ancillary roofs are permitted on flat-roofed buildings, but must comply with principal roof pitch requirements. |
2 | No minimum value required where facade is located on a property line. See § 30-329 regarding treatment of blank walls. |
Minimum | Maximum | ||
|---|---|---|---|
Lot | |||
A | Frontage width (feet) | 140 | — |
B | Lot depth (feet) | 125 | — |
C | Lot size (square feet) | 17,500 | — |
D | Building coverage | — | 30%1 |
E | Improved coverage | 85%1 | |
Setbacks, Principal Buildings | |||
F | Build-to-line | See district standards in Part 2. | |
G | Side yard (individual) (feet) | 10 | — |
Side yard (total) (feet) | 50 | — | |
H | Rear yard (feet) | 25 | — |
Note: | |
1 | Building coverage of up to 50% is permitted so long as overall lot coverage does not exceed 60%. |
Size of Standard | |||
|---|---|---|---|
Applies to All Sizes | |||
Minimum | Maximum | ||
Main Body | |||
A | Building height (floors/feet) | See district standards in Part 2. | |
B | Ground floor height (floor to ceiling, feet) | 12 | — |
C | Upper floor height (floor to ceiling, feet) | 9 | — |
D | Finished floor elevation (inches) | 0 | — |
Massing and Composition | |||
E | Principal roof pitch (rise:run) | — | 3:12 |
Ancillary roof pitch | No greater than principal roof | ||
F | Horizontal articulation | See design standards in Subsection 30-328.2. | |
G | Transparency, street-facing facades | See frontage standards in Article 3C. | |
H | Transparency, non-street-facing facades2 | 40% | 75% |
Notes: | |
|---|---|
1 | Pitched ancillary roofs are permitted on flat-roofed buildings, but must comply with principal roof pitch requirements. |
2 | No minimum value required where a façade is located on a property line. See § 30-329 regarding treatment of blank walls. |
Minimum | Maximum | ||
|---|---|---|---|
Lot | |||
A | Frontage width (feet) | 100 | — |
B | Lot depth (feet) | 125 | — |
C | Lot size (square feet) | 30,000 | — |
Setbacks, Buildings | |||
D | Build-to-line setback | See district standards in Part 2. | |
E | Minimum side yard (individual) (feet) | 0 or 15 | 35 |
F | Rear yard (feet) | 20 | — |
Coverage | |||
G | Building coverage | — | 70% |
H | Improved coverage | — | 95% |
I | Floor area ratio1 | — | 2.74 |
Note: | |
1 | Excluding structured parking |
Minimum | Maximum | ||
|---|---|---|---|
Main Body | |||
A | Building height (floors/feet) | See district standards in Part 2. | |
B | Ground floor height (floor to ceiling, feet) | 12 | — |
C | Upper floor height (floor to ceiling, feet) | 9 | — |
D | Finished floor elevation (inches) | 0 | |
Massing and Composition | |||
E | Principal roof pitch (rise:run) | — | 3:12 |
Accessory roof pitch | No greater than principal roof | ||
F | Horizontal articulation | See design standards in Subsection 30-328.2. | |
G | Transparency, street-facing facades | See frontage standards in Article 3C. | |
H | Transparency, non-street-facing facades1 | 25% | 75% |
Note: | |
1 | No minimum value required where a façade is located on a property line. See § 30-329 regarding treatment of blank walls. |
Minimum | Maximum | ||
|---|---|---|---|
Lot | |||
A | Frontage width (feet) | 25 | 75 |
B | Lot depth (feet) | 65 | — |
C | Lot size (square feet) | 1,625 | — |
Setbacks, Principal Buildings | |||
D | Build-to-line | See district standards in Part 2. | |
E | Side yard (individual) (feet) | 0 or 15 | 35 |
F | Rear yard (feet) | 20 | — |
Coverage, Principal Buildings | |||
G | Building coverage | — | 85% |
H | Improved coverage | — | 85%1 |
Note: | |
1 | Urban, small buildings in the TC District may be permitted up to 95% improved coverage. |
Minimum | Maximum | ||
|---|---|---|---|
Building | |||
A | Building width | N/A | N/A |
B | Building depth | N/A | N/A |
C | Build-to-line occupancy C /A | 95% | — |
D | Main entrance | Front | |
E | Driveway width (feet) | N/A | 24 |
F | Distance between entrances1 (feet) | — | 40 |
Parking | |||
G | Mid-block connection width (when provided) (feet) | 18 | N/A |
Note: | |
1 | This standard shall be excluded insofar as deviation would require conformance with FAR limitations as may be imposed pursuant to district standards. |
Minimum | Maximum | ||
|---|---|---|---|
Main Body | |||
A | Building height (floors/feet) | See district standards in Part 2. | |
B | Ground floor height (floor to ceiling, feet) | 12 | — |
C | Upper floor height (floor to ceiling, feet) | 9 | — |
D | Finished floor elevation (inches) | — | 0 |
Massing and Composition | |||
E | Principal roof pitch (rise:run) | — | 3:12 |
Ancillary roof pitch | No greater than principal roof | ||
F | Horizontal articulation | See design standards in Subsection 30-328.2. | |
G | Transparency, street-facing facades | See frontage standards in Article 3C. | |
H | Transparency, non-street-facing facades3 | 30% | 75%2 |
Notes: | |
|---|---|
1 | Pitched ancillary roofs are permitted on flat-roofed buildings, but must comply with principal roof pitch requirements. |
2 | Minimum and maximum transparency standards do not apply to buildings with a side yard setback of zero feet. |
3 | No minimum value required where facade is located on a property line. See § 30-329 regarding treatment of blank walls. |
Minimum | Maximum | ||
|---|---|---|---|
Lot | |||
A | Frontage width (feet) | 75 | 250 |
B | Lot depth (feet) | 100 | — |
C | Lot size (square feet) | 7,000 | — |
Setbacks, Buildings | |||
D | Build-to-line setback | See district standards in Part 2. | |
E | Side yard (individual) (feet) | 0 or 15 | 35 |
F | Rear yard (feet) | 20 | — |
Coverage, Buildings | |||
G | Building coverage | — | 85% |
H | Improved coverage | — | 95% |
Minimum | Maximum | ||
|---|---|---|---|
Building | |||
A | Building width (feet) | N/A | 250 |
B | Building depth | N/A | N/A |
C | Build-to-line occupancy C /A | 95% | — |
D | Main entrance | Front | |
E | Driveway width (feet) | N/A | 24 |
F | Distance between entrances1 (feet) | N/A | 40 |
Parking | |||
G | Mid-block connection width (when provided) (feet) | 18 | N/A |
Note: | |
1 | This standard shall be excluded insofar as deviation would require conformance with FAR limitations as may be imposed pursuant to district standards. |
Minimum | Maximum | ||
|---|---|---|---|
Main Body | |||
A | Building height (floors/feet) | See district standards in Part 2. | |
B | Ground floor height (floor to ceiling, feet) | 12 | — |
C | Upper floor height (floor to ceiling, feet) | 9 | — |
D | Finished floor elevation (inches) | — | 0 |
Massing and Composition | |||
E | Principal roof pitch (rise:run) | — | 3:12 |
Accessory roof pitch | No greater than principal roof | ||
F | Horizontal articulation | See design standards in Subsection 30-328.2. | |
G | Transparency, street-facing facades | See frontage standards in Article 3C. | |
H | Transparency, non-street-facing facades3 | 40% | 75%2 |
Notes: | |
1 | Pitched ancillary roofs are permitted on flat-roofed buildings, but must comply with principal roof pitch requirements. |
2 | Minimum and maximum transparency standards do not apply to buildings with a side yard setback of zero feet. |
3 | No minimum value required where facade is located on a property line. See § 30-329 regarding treatment of blank walls. |
Regulation | Minimum | Maximum | |
i. | Active ground floor use required | Yes | |
ii. | Transparency, ground floor | 60% | 80% |
iii. | Transparency, upper floors | 30% | 70% |
iv. | Build-to-line | See district standards. | |
v. | Encroachments (feet) | — | 10 |
vi. | Step back required (stories/feet) | 4/42 | 4/53 |
vii. | Step back requirement | 12.5% of building depth, minimum 10 feet and maximum 20 feet | |
Key: |
P: Permitted |
NP: Not permitted |
Building Elements | Permission |
|---|---|
Balcony | NP |
Bay window | P |
Porches | NP |
Stoops | NP |
Terraces | P |
Awnings | P |
Lobby | P |
Porte cocheres | NP |
Attached side garages | NP |
Note: |
See § 30-333 for regulations regarding building elements. |
Regulation | Minimum | Maximum | |
|---|---|---|---|
i. | Active ground floor use required | Yes | |
ii. | Transparency, ground floor | 60% | 80% |
iii. | Transparency, upper floors | 30% | 70% |
iv. | Build-to-line | See district standards. | |
v. | Encroachments (feet) | — | 10 |
vi. | Step back required (stories/feet) | 4/42 | 4/53 |
vii. | Step back requirement | 12.5% of building depth, minimum 10 feet and maximum 20 feet | |
Key: |
P: Permitted |
NP: Not permitted |
Building Elements | Permission |
|---|---|
Balcony | NP |
Bay window | P |
Porches | NP |
Stoops | NP |
Terraces | P |
Awnings | P |
Lobby | P |
Porte cocheres | NP |
Attached side garages | NP |
Note: |
See § 30-333 for regulations regarding building elements. |
Regulation | Minimum | Maximum | |
|---|---|---|---|
i. | Active ground floor use required | No | |
ii. | Transparency, ground floor | 30% | — |
iii. | Transparency, upper floors | 25% | — |
iv. | Build-to-line | See district standards. | |
v. | Encroachments past build-to-line (feet) | — | 10 |
vi. | Step back required (stories/feet) | 4/42 | 4/53 |
vii. | Step back requirement | 12.5% of building depth, minimum 10 feet and maximum 20 feet | |
Key: |
P: Permitted |
NP: Not permitted |
Building Elements | Permission |
|---|---|
Balcony | P |
Bay window | P |
Porches | NP |
Stoops | NP |
Terraces | P |
Awnings | P |
Lobby | P |
Porte cocheres | NP |
Attached side garages | NP |
Note: |
See § 30-333 for regulations regarding building elements. |
Regulation | Minimum | Maximum | |
|---|---|---|---|
i. | Active ground floor use required | No | |
ii. | Transparency, ground floor | 30% | 80% |
iii. | Transparency, upper floors | 25% | — |
iv. | Build-to-line | See district standards. | |
v. | Encroachments | — | 10 |
vi. | Step back required (stories/feet) | 2/28 | 3/41 |
vii. | Step back requirement | 12.5% of building depth, minimum 10 feet and maximum 20 feet | |
Key: |
P: Permitted |
NP: Not permitted |
Building Elements | Permission |
|---|---|
Balcony | P |
Bay window | P |
Porches | NP |
Stoops | P |
Terraces | P |
Awnings | P |
Lobby | P |
Porte cocheres | NP |
Attached side garages | NP |
Note: |
See § 30-333 for regulations regarding building elements. |
Regulation | Minimum | Maximum | |
|---|---|---|---|
i. | Active ground floor use required | No | |
ii. | Transparency, ground floor | 25% | — |
iii. | Transparency, upper floors | 20% | — |
iv. | Build-to-line | See district standards. | |
v. | Encroachments (feet) | — | 10 |
vi. | Step back required (stories/feet) | 4/42 | 4/53 |
vii. | Step back requirement | 12.5% of building depth, minimum 10 feet and maximum 20 feet | |
Key: |
P: Permitted |
NP: Not permitted |
Building Elements | Permission |
|---|---|
Balcony | P |
Bay window | P |
Porches | P |
Stoops | P |
Terraces | P |
Awnings | P |
Lobby | P |
Porte cocheres | NP |
Attached side garages | NP |
Note: |
See § 30-333 for regulations regarding building elements. |
Regulation | Minimum | Maximum | |
|---|---|---|---|
i. | Active ground floor use required | No | |
ii. | Transparency, ground floor | 35% | 75% |
iii. | Transparency, upper floors | 20% | — |
iv. | Build-to-line | See district standards. | |
v. | Encroachments (feet) | — | 10 |
vi. | Step back required (stories/feet) | 4/42 | 4/53 |
vii. | Step back requirement | 12.5% of building depth, minimum 10 feet and maximum 20 feet | |
Key: |
P: Permitted |
NP: Not permitted |
Building Elements | Permission |
|---|---|
Balcony | P |
Bay window | P |
Porches | P |
Stoops | P |
Terraces | P |
Awnings | P |
Lobby | P |
Porte cocheres | NP |
Attached side garages | NP |
Note: |
See § 30-333 for regulations regarding building elements. |
Key: |
P: Permitted |
NP: Not permitted |
Building Elements | Permission |
|---|---|
Balcony | P |
Bay window | P |
Porches | NP |
Stoops | NP |
Terraces | P |
Awnings | P |
Lobby | P |
Porte cocheres | NP |
Attached side garages | NP |
Note: |
See § 30-333 for regulations regarding building elements. |
Regulation | Minimum | Maximum | |
|---|---|---|---|
i. | Active ground floor use required | No | |
ii. | Transparency, ground floor | 25% | — |
iii. | Transparency, upper floors | 20% | — |
iv. | Build-to-line | See district standards. | |
v. | Encroachments (feet) | — | 10 |
vi. | Step back required (stories/feet) | — | 3/41 |
vii. | Step back requirement | 12.5% of building depth, minimum 10 feet and maximum 20 feet | |
Key: |
P: Permitted |
NP: Not permitted |
Building Elements | Permission |
|---|---|
Balcony | P |
Bay window | P |
Porches | P |
Stoops | P |
Terraces | P |
Awnings | NP |
Lobby | NP |
Porte cocheres | NP |
Attached side garages | P |
Note: |
See § 30-333 for regulations regarding building elements. |
Regulation | Minimum | Maximum | |
|---|---|---|---|
i. | Active ground floor use required | No | |
ii. | Transparency, ground floor | 25% | — |
iii. | Transparency, upper floors | 20% | — |
iv. | Build-to-line | See district standards. | |
v. | Encroachments (feet) | — | 10 |
vi. | Step back required (stories/feet) | — | 3/41 |
vii. | Step back requirement | 12.5% of building depth, minimum 10 feet and maximum 20 feet | |
Key: |
P: Permitted |
NP: Not permitted |
Building Elements | Permission |
|---|---|
Balcony | P |
Bay window | P |
Porches | P |
Stoops | P |
Terraces | P |
Awnings | NP |
Lobby | NP |
Porte cocheres | NP |
Attached side garages | NP |
Note: |
See § 30-333 for regulations regarding building elements. |
Regulation | Minimum | Maximum | |
|---|---|---|---|
i. | Active ground floor use required | No | |
ii. | Transparency, ground floor | 25% | — |
iii. | Transparency, upper floors | 20% | — |
iv. | Build-to-line | See district standards. | |
v. | Encroachments (feet) | — | 10 |
vi. | Step back required (stories/feet) | — | 3/41 |
vii. | Step back requirement | 12.5% of building depth, minimum 10 feet and maximum 20 feet | |
Key: |
P: Permitted |
NP: Not permitted |
Building Elements | Permission |
|---|---|
Balcony | P |
Bay window | P |
Porches | P |
Stoops | P |
Terraces | P |
Awnings | NP |
Lobby | NP |
Porte cocheres | NP |
Attached side garages | NP |
Note: |
See § 30-333 for regulations regarding building elements. |
Key: |
P: Permitted |
NP: Not permitted |
Building Elements | Permission |
|---|---|
Balcony | P |
Bay window | P |
Porches | P |
Stoops | P |
Terraces | P |
Awnings | NP |
Lobby | NP |
Porte cocheres | P |
Attached side garages | NP |
Note: |
See § 30-333 for regulations regarding building elements. |