Site Plan and Subdivision Design and Performance Standards
BUILDING SPACING FORMULA | ||
|---|---|---|
Wall height x Multiplier = Distance of separation between buildings. | ||
Building Wall Relationship | Multiplier | Minimum Spacing |
Front wall to front wall | 1.50 | 30 feet |
Front wall to rear wall | 2.00 | 40 feet |
Front wall to side wall | 1.50 | 30 feet |
Front wall to windowless side wall | 1.50 | 30 feet |
Rear wall to rear wall | 2.00 | 40 feet |
Rear wall to side wall | 2.00 | 40 feet |
Rear wall to windowless side wall | 1.50 | 30 feet |
Side wall to side wall | 0.75 | 20 feet |
Side wall to windowless side wall | 0.75 | 15 feet |
Windowless side wall to windowless side wall | 0.75 | 15 feet |
NOTE: The minimum spacing standards listed above are generally intended for average two-story buildings and, therefore, may need to be adjusted for buildings of other heights. In addition, this building spacing formula shall only determine the spacing of buildings within the multiple-building development property. |
AVERAGE ILLUMINATION LEVELS | |
|---|---|
Use Area | Average Illumination Level |
Parking lots | 1.0-2.5 fc |
Loading area | 3.0-5.0 fc |
Pedestrian walkways | 0.5-1.0 fc |
LOADING BERTH STANDARDS | ||
|---|---|---|
Use | Total Floor Area (square feet) | Number of Loading Berths |
Funeral homes and mortuaries | Up to 5,000 | 1 |
5,000 or more | 2 | |
All other businesses and commercial uses | Up to 10,000 | 0 |
From 10,001 to 23,999 | 1 | |
From 24,000 to 39,999 | 2 | |
40,000 or more | 3 | |
Light industrial and warehouses | Up to 5,000 | 1 |
5,000 to 19,999 | 2 | |
20,000 to 39,999 | 3 | |
40,000 or more | 3+1 for each additional 20,000 square feet | |
AISLE DIMENSION STANDARDS | ||
|---|---|---|
Angle of Parking Stall (degrees) | Width of One-Way Traffic Aisle | Width of Two-Way Traffic Aisle |
0 (parallel) | 11 feet | 22 feet |
30 | 12 feet | Not permitted |
45 | 13 feet | Not permitted |
60 | 18 feet | Not permitted |
90 (perpendicular) | 24 feet | 24 feet |
Site Plan and Subdivision Design and Performance Standards
BUILDING SPACING FORMULA | ||
|---|---|---|
Wall height x Multiplier = Distance of separation between buildings. | ||
Building Wall Relationship | Multiplier | Minimum Spacing |
Front wall to front wall | 1.50 | 30 feet |
Front wall to rear wall | 2.00 | 40 feet |
Front wall to side wall | 1.50 | 30 feet |
Front wall to windowless side wall | 1.50 | 30 feet |
Rear wall to rear wall | 2.00 | 40 feet |
Rear wall to side wall | 2.00 | 40 feet |
Rear wall to windowless side wall | 1.50 | 30 feet |
Side wall to side wall | 0.75 | 20 feet |
Side wall to windowless side wall | 0.75 | 15 feet |
Windowless side wall to windowless side wall | 0.75 | 15 feet |
NOTE: The minimum spacing standards listed above are generally intended for average two-story buildings and, therefore, may need to be adjusted for buildings of other heights. In addition, this building spacing formula shall only determine the spacing of buildings within the multiple-building development property. |
AVERAGE ILLUMINATION LEVELS | |
|---|---|
Use Area | Average Illumination Level |
Parking lots | 1.0-2.5 fc |
Loading area | 3.0-5.0 fc |
Pedestrian walkways | 0.5-1.0 fc |
LOADING BERTH STANDARDS | ||
|---|---|---|
Use | Total Floor Area (square feet) | Number of Loading Berths |
Funeral homes and mortuaries | Up to 5,000 | 1 |
5,000 or more | 2 | |
All other businesses and commercial uses | Up to 10,000 | 0 |
From 10,001 to 23,999 | 1 | |
From 24,000 to 39,999 | 2 | |
40,000 or more | 3 | |
Light industrial and warehouses | Up to 5,000 | 1 |
5,000 to 19,999 | 2 | |
20,000 to 39,999 | 3 | |
40,000 or more | 3+1 for each additional 20,000 square feet | |
AISLE DIMENSION STANDARDS | ||
|---|---|---|
Angle of Parking Stall (degrees) | Width of One-Way Traffic Aisle | Width of Two-Way Traffic Aisle |
0 (parallel) | 11 feet | 22 feet |
30 | 12 feet | Not permitted |
45 | 13 feet | Not permitted |
60 | 18 feet | Not permitted |
90 (perpendicular) | 24 feet | 24 feet |