Zone Controls
ZONES | |
|---|---|
ZONE NAME | ZONE DESIGNATION |
Very Low Density Residential | R-1 |
Low Density Residential | R-2 |
Low/Moderate Density Residential | R-3 |
Moderate Density Residential | R-4 |
Medium Density Residential | R-5 |
Medium/High Density Residential | R-6 |
High Density Residential | R-7 |
Residential Historic Districts | R-VWB, R-CA, R-PW, R-HA, R-B, R-NH |
Historic Park Zone | GB, CB |
Neighborhood Commercial | NC |
Professional Office | PO |
General Commercial | GC |
Mixed Use | MU |
Light Industrial | LI |
Transit Oriented Development Downtown Central Business District | TODD/CBD |
Transit Oriented Development Downtown North Avenue Historic District | TODD/NAHD |
Transit Oriented Development Downtown Cleveland Arts District | TODD/CLAD |
Transit Oriented Development Downtown Parking District | TODD/PD |
Transit Oriented Development Downtown College District | TODD/CD |
Transit Oriented Development Downtown Civic Historic District | TODD/CHD |
Transit Oriented Development Downtown Transition District | TODD/TD |
Transit Oriented Development Netherwood Train Station Area Zone | TODN/TSA |
Transit Oriented Development Netherwood Trainside Commercial Zone | TODN/TSC |
Transit Oriented Development Netherwood Trainside Residential Zone | TODN/TSR |
Transit Oriented Development Netherwood Parkside Residential 1 Zone | TODN/PSR1 |
Transit Oriented Development Netherwood Parkside Residential 2 Zone | TODN/PSR2 |
Transit Oriented Development Netherwood High-Density Residential | TODN/R-8 |
Transit Oriented Development Netherwood Professional Office | TODN/PO |
BUFFERING AND SCREENING REQUIREMENTS | ||
|---|---|---|
Type Use/Subject | Width Buffering | Height of Screening at Time of Planting |
Residential uses other than single- and two-family dwellings | 5' | 3-4' |
Nonresidential uses | 10' | 6' |
Light industrial uses | 25' | 6' |
Editor's Note: This chapter was adopted December 2, 2002 by Ordinance MC 2002-29. |
Table 102.2(1) | |||||
|---|---|---|---|---|---|
Map Panel # | Effective Date | Suffix | Map Panel # | Effective Date | Suffix |
34039C0028 | 9/20/2006 | F | 34039C0040 | 9/20/2006 | F |
34039C0029 | 9/20/2006 | F | |||
34039C0038 | 9/20/2006 | F | |||
34039C0039 | 9/20/2006 | F | |||
Table 102.2(2) | |||||
|---|---|---|---|---|---|
Map Panel # | Preliminary Date | Suffix | Map Panel # | Preliminary Date | Suffix |
34039C0028 | 4/18/2016 | G | 34039C0040 | 4/18/2016 | G |
34039C0029 | 4/18/2016 | G | |||
34039C0038 | 4/18/2016 | G | |||
34039C0039 | 4/18/2016 | G | |||
Table 102.2(3) | ||
|---|---|---|
Name of Studied Water | File Name | Map Number |
Stream 14-14-2-2 | C0000012 | 2 |
Stream 14-14-2-2, Stream 14-14-2-2 Trib | C0000013 | 1 |
Cedar Bk | C0000029 | 4 |
Green Bk | C0000040 | 1 |
Branch 22 | SUPPX007 | BR22-2 |
Branch 22 | SUPPX008 | BR22-3 |
Green Bk | SUPPX012 | G-4 |
Green Bk | SUPPX013 | G-5 |
Green Bk | Y0000002 | 1 of 6 |
Green Bk | Y0000003 | 2 of 6 |
Green Bk | Y0000004 | 3 of 6 |
Green Bk | Y0000005 | 4 of 6 |
Green Bk | Y0000006 | 5 of 6 |
Stony Bk | Y0000007 | 6 of 6 |
Stony Bk | Y0000008 | 6 of 6 |
Cedar Bk | Y0000009 | 6 of 6 |
It shall be the responsibility of the Floodplain Administrator to verify that the applicant's proposed Best Available Flood Hazard Data Area and the Local Design Flood Elevation in any development permit accurately applies the best available flood hazard data and methodologies for determining flood hazard areas and design elevations described in Sections 17:9-30.102.2 and 17:9-30.102.3 respectively. This information shall be provided to the Construction Official and documented according to Section 17:9-30.103.15. |
The Floodplain Administrator is authorized to waive the submission of site plans, construction documents, and other data that are required by these regulations but that are not required to be prepared by a registered design professional when it is found that the nature of the proposed development is such that the review of such submissions is not necessary to ascertain compliance. |
Studies, analyses, and computations shall be submitted in sufficient detail to allow review and approval by the Floodplain Administrator prior to floodplain development permit issuance. The accuracy of data submitted for such determination shall be the responsibility of the applicant. Where the data are to be used to support a Letter of Map Change (LOMC) from FEMA, the applicant shall be responsible for satisfying the submittal requirements and pay the processing fees. |
Note: Substantially damaged properties and substantially improved properties that have not been elevated are not considered "lawfully existing" for the purposes of the NFIP. This definition is included in this chapter to clarify the applicability of any more stringent statewide floodplain management standards required under the FHACA. |
Permanent construction does not include land preparation, such as clearing, grading, and filling, nor does it include the installation of streets and/or walkways; nor does it include excavation for a basement, footings, piers, or foundations or the erection of temporary forms; nor does it include the installation on the property of accessory buildings, such as garages or sheds not occupied as dwelling units or not part of the main structure. Such development must also be permitted and must meet new requirements when National Flood Insurance Program (NFIP) maps are issued or revised and Base Flood Elevation's (BFEs) increase or zones change. |
For a substantial improvement, the actual start of construction means the first alteration of any wall, ceiling, floor, or other structural part of a building, whether or not that alteration affects the external dimensions of the building. |
For determining if new construction and substantial improvements within the Coastal Barrier Resources System (CBRS) can obtain flood insurance, a different definition applies. |
Exception. Where such equipment and appliances are designed and installed to prevent water from entering or accumulating within their components and the systems are constructed to resist hydrostatic and hydrodynamic loads and stresses, including the effects of buoyancy, during the occurrence of flooding up to the elevation required by Section 17:9-30.801.2, the systems and equipment shall be permitted to be located below that elevation. Electrical wiring systems shall be permitted below the design flood elevation provided they conform to the provisions of NFPA 70 (National Electric Code). |
Exception: Electrical systems, equipment and components, and heating, ventilating, air conditioning, and plumbing appliances, plumbing fixtures, duct systems, and other service equipment shall be permitted to be located below the Local Design Flood Elevation provided that they are designed and installed to prevent water from entering or accumulating within the components and to resist hydrostatic and hydrodynamic loads and stresses, including the effects of buoyancy, during the occurrence of flooding to the Local Design Flood Elevation in compliance with the flood-resistant construction requirements of ASCE 24. Electrical wiring systems shall be permitted to be located below the Local Design Flood Elevation provided they conform to the provisions of NFPA 70 (National Electric Code). |
Editor's Note: Schedule B, referred to herein may be found as an attachment to this chapter. |
Editor's Note: Schedule B, referred to herein may be found as an attachment to this chapter. |
Editor's Note: Ordinance No. MC 2002-29 which adopted this chapter was adopted December 2, 2002 and became effective December 22, 2002. |
Editor's Note: Ordinance No. MC 2002-29 which adopted this chapter was adopted December 2, 2002 and became effective December 22, 2002. |
TABLE OF PARKING REGULATIONS | ||
|---|---|---|
Use | Off-Street Parking Requirements | |
Residential | Single-family | See RSIS Standards |
Two-family | ||
Townhouse | ||
Apartment | ||
Art studio/art gallery | 1 space per 300 square feet of gross floor area | |
Assisted living facility | 1 space per 2.5 rooms | |
Automobile repair shop | 1 space per 300 square feet of gross floor area plus 3 spaces per work bay | |
Automobile service station | 1 space per two pumps or 4 spaces, whichever is greater | |
Automotive body shop | 2 spaces per bay and work area | |
Automotive dealership | 2.5 spaces per 1,000 square feet per gross floor area of interior sales space + 3 spaces per service bay | |
Bank | 1 space per 300 square feet of gross floor area | |
Banquet hall | 1 space per 3 persons based upon the maximum number of persons that can be accommodated at the same time in accordance with the design capacity of the structure under BOCA Regulations + 1 space for every two employees on the maximum shift | |
Bed and breakfast homestay | 1 space per guest room + 2 spaces per dwelling unit | |
Bed and breakfast guesthouse | 1 space per guest room + 1 space per employee + 2 spaces per dwelling unit | |
Car wash | 1 space per employee + 5 spaces per washing lane | |
Childcare facility | 1 space per employee but no less than 5 spaces | |
Community center | 4 spaces per 1,000 square feet of gross floor area | |
Community residence for the developmentally disabled | 1 space per employee | |
Family day care | 1 space per employee | |
Funeral home | 1 space per 200 square feet of gross floor area | |
Health club | 1 space per 75 square feet of gross floor area | |
Home Occupation | 1 space per employee + applicable RSIS requirements based on dwelling unit type | |
Hospital | 2 spaces per bed | |
Hotel | 1 space per guest room + 1 space per 2 employees + 1 space per 150 square feet of banquet and conference space | |
House of worship | 1 space per 4 seats; every two and one-half (2 1/2) feet (thirty (30) inches) of a pew measured horizontally shall be considered a seat | |
Laundromat | 1 space per 2 washer and dryer machines | |
Manufacturing and assembly | 1 space per 1,000 square feet of gross floor area | |
Medical office | 1 space per 175 square feet of gross floor area | |
Nightclub | 1 space per 3 persons based upon the maximum number of persons that can be accommodated at the same time in accordance with the design capacity of the structure under BOCA Regulations | |
Nursery and landscaping facility | No less than 3 spaces plus 1 space per 300 square feet of interior retail | |
Nursing home | 1 space per 3 resident rooms | |
Office | 1 space per 400 square feet of gross floor area | |
Personal service | 1 space per 300 square feet of gross floor area | |
Research | 1 space per 1,000 square feet of gross floor area | |
Restaurant | 1 space per 3 seats | |
Residential units in all TODD Zones | 1 parking space for each dwelling unit | |
Residential units in all TODN Zones | 1 parking space for each dwelling unit | |
Retail sales and service | 1 space per 300 square feet of gross floor area | |
Senior/Age Restricted Housing | 1 space for every three residential dwelling units | |
Tavern | 1 space per 2 seats | |
Theater | 1 space per 3 seats | |
Veterinary hospital | 1 space per 300 square feet of gross floor area | |
Warehouse & distribution facility | 1 space per 2,000 square feet of gross floor area | |
Dwelling Unit Type | Minimum Floor Area (square feet) |
|---|---|
Studio/Efficiency Apartment | 500 S.F. |
One (1) Bedroom Apartments | 750 S.F. |
Two (2) Bedroom Apartments | 1,000 S.F. |
Apartments with three (3) or more bedrooms | 1,100 S.F. + 150 S.F. per additional bedroom |
Zone | Minimum Floor Area (square feet) |
|---|---|
R-1 | 2,500 S.F. |
R-2 | 1,700 S.F. |
R-3 | 1,300 S.F. |
R-4 | 750 S.F. |
R-5 | 750 S.F. |
R-6 | 1,500 S.F. |
R-7 | 1,100 S.F. |
R-CA | 1,700 S.F. |
R-HA | 2,500 S.F. |
R-VWB | 2,500 S.F. (R-1 Zone); 1,700 S.F. (R-2 Zone) |
For subparagraphs a, b, c and d above, dwellings shall be deemed to be like each other in any dimension in which the difference between them is not more than six (6) feet. |
For subparagraph e above, dwellings shall be deemed to be like each other in any dimension in which the difference between them is not more than three (3) feet. |
For subparagraph f above, dwellings shall be deemed to be like each other if the difference between materials used is not more than thirty-five percent (35%) of the facade area. |
Dwellings between which the only difference in relative location of elements is end-to-end or side-to-side reversal of elements shall be deemed to be like each other in relative location of such elements. |
1. | Minimum Lot Area | 1 acre | ||
2. | Maximum Density | 50 dwelling units/acre | ||
3. | Minimum Lot Width | 150 feet (measured at arterial roadway right-of-way; 50 feet at all other roadways, if abutting) | ||
4. | Minimum Lot Depth | 200 feet | ||
5. | Minimum Front Yard Setback | 0 feet | ||
6. | Minimum Side Yard Setback | 10 feet adjacent to residential; 5 feet adjacent to commercial | ||
7. | Minimum Rear Yard Setback | 5 feet (except ingress/egress stairs can encroach into the rear yard provided at least a 3-foot setback is maintained) | ||
8. | Maximum Floor Area Ratio | 3.5 | ||
9. | Maximum Percent Building Cover | 75% | ||
10. | Maximum Percent Total Lot Cover | 90% | ||
11. | Minimum Number of Stories | 3 | ||
12. | Maximum Number of Stories | 5 | ||
13. | Maximum Building Height | 65 feet (Measured from the average elevation of the existing grade elevations found at the building corners) | ||
14. | Minimum Improvable Area | 32,000 square feet | ||
15. | Minimum Buffer Width When Abutting Residential Use | 5 feet (except ingress/egress stairs can encroach into the buffer provided at least a 3 foot buffer is maintained) | ||
16. | Minimum Driveway, Parking Area Buffer | 5 feet | ||
17. | Minimum Driveway Setback From Residential Use | 5 feet | ||
18. | Parking Stall Number | Four (4) stalls per 1,000 square feet of floor area dedicated to activity use where stand alone development is proposed. Where mixed use development is proposed, 1.5 stalls per dwelling unit. Shared parking to accommodate the needs of the nonresidential component is permitted provided each residential unit will have at least one dedicated parking space at all times. | ||
Tree Replacement Requirements Table | |||
|---|---|---|---|
Category | Tree Removed (DBH) | Tree Replacement Criteria | Application Fee |
1 | 6" (for non-street trees) to 12.99" | Replant 1 tree with a minimum tree caliper of 1.5" for each tree removed | $75 |
2 | DBH of 13" to 22.99" | Replant 2 trees with minimum tree calipers of 1.5" for each tree removed | $100 |
3 | DBH of 23" to 32.99" | Replant 3 trees with minimum tree calipers of 1.5" for each tree removed | $150 |
4 | DBH of 33" or greater | Replant 4 trees with minimum tree calipers of 1.5" for each tree removed | $175 |
Zone Controls
ZONES | |
|---|---|
ZONE NAME | ZONE DESIGNATION |
Very Low Density Residential | R-1 |
Low Density Residential | R-2 |
Low/Moderate Density Residential | R-3 |
Moderate Density Residential | R-4 |
Medium Density Residential | R-5 |
Medium/High Density Residential | R-6 |
High Density Residential | R-7 |
Residential Historic Districts | R-VWB, R-CA, R-PW, R-HA, R-B, R-NH |
Historic Park Zone | GB, CB |
Neighborhood Commercial | NC |
Professional Office | PO |
General Commercial | GC |
Mixed Use | MU |
Light Industrial | LI |
Transit Oriented Development Downtown Central Business District | TODD/CBD |
Transit Oriented Development Downtown North Avenue Historic District | TODD/NAHD |
Transit Oriented Development Downtown Cleveland Arts District | TODD/CLAD |
Transit Oriented Development Downtown Parking District | TODD/PD |
Transit Oriented Development Downtown College District | TODD/CD |
Transit Oriented Development Downtown Civic Historic District | TODD/CHD |
Transit Oriented Development Downtown Transition District | TODD/TD |
Transit Oriented Development Netherwood Train Station Area Zone | TODN/TSA |
Transit Oriented Development Netherwood Trainside Commercial Zone | TODN/TSC |
Transit Oriented Development Netherwood Trainside Residential Zone | TODN/TSR |
Transit Oriented Development Netherwood Parkside Residential 1 Zone | TODN/PSR1 |
Transit Oriented Development Netherwood Parkside Residential 2 Zone | TODN/PSR2 |
Transit Oriented Development Netherwood High-Density Residential | TODN/R-8 |
Transit Oriented Development Netherwood Professional Office | TODN/PO |
BUFFERING AND SCREENING REQUIREMENTS | ||
|---|---|---|
Type Use/Subject | Width Buffering | Height of Screening at Time of Planting |
Residential uses other than single- and two-family dwellings | 5' | 3-4' |
Nonresidential uses | 10' | 6' |
Light industrial uses | 25' | 6' |
Editor's Note: This chapter was adopted December 2, 2002 by Ordinance MC 2002-29. |
Table 102.2(1) | |||||
|---|---|---|---|---|---|
Map Panel # | Effective Date | Suffix | Map Panel # | Effective Date | Suffix |
34039C0028 | 9/20/2006 | F | 34039C0040 | 9/20/2006 | F |
34039C0029 | 9/20/2006 | F | |||
34039C0038 | 9/20/2006 | F | |||
34039C0039 | 9/20/2006 | F | |||
Table 102.2(2) | |||||
|---|---|---|---|---|---|
Map Panel # | Preliminary Date | Suffix | Map Panel # | Preliminary Date | Suffix |
34039C0028 | 4/18/2016 | G | 34039C0040 | 4/18/2016 | G |
34039C0029 | 4/18/2016 | G | |||
34039C0038 | 4/18/2016 | G | |||
34039C0039 | 4/18/2016 | G | |||
Table 102.2(3) | ||
|---|---|---|
Name of Studied Water | File Name | Map Number |
Stream 14-14-2-2 | C0000012 | 2 |
Stream 14-14-2-2, Stream 14-14-2-2 Trib | C0000013 | 1 |
Cedar Bk | C0000029 | 4 |
Green Bk | C0000040 | 1 |
Branch 22 | SUPPX007 | BR22-2 |
Branch 22 | SUPPX008 | BR22-3 |
Green Bk | SUPPX012 | G-4 |
Green Bk | SUPPX013 | G-5 |
Green Bk | Y0000002 | 1 of 6 |
Green Bk | Y0000003 | 2 of 6 |
Green Bk | Y0000004 | 3 of 6 |
Green Bk | Y0000005 | 4 of 6 |
Green Bk | Y0000006 | 5 of 6 |
Stony Bk | Y0000007 | 6 of 6 |
Stony Bk | Y0000008 | 6 of 6 |
Cedar Bk | Y0000009 | 6 of 6 |
It shall be the responsibility of the Floodplain Administrator to verify that the applicant's proposed Best Available Flood Hazard Data Area and the Local Design Flood Elevation in any development permit accurately applies the best available flood hazard data and methodologies for determining flood hazard areas and design elevations described in Sections 17:9-30.102.2 and 17:9-30.102.3 respectively. This information shall be provided to the Construction Official and documented according to Section 17:9-30.103.15. |
The Floodplain Administrator is authorized to waive the submission of site plans, construction documents, and other data that are required by these regulations but that are not required to be prepared by a registered design professional when it is found that the nature of the proposed development is such that the review of such submissions is not necessary to ascertain compliance. |
Studies, analyses, and computations shall be submitted in sufficient detail to allow review and approval by the Floodplain Administrator prior to floodplain development permit issuance. The accuracy of data submitted for such determination shall be the responsibility of the applicant. Where the data are to be used to support a Letter of Map Change (LOMC) from FEMA, the applicant shall be responsible for satisfying the submittal requirements and pay the processing fees. |
Note: Substantially damaged properties and substantially improved properties that have not been elevated are not considered "lawfully existing" for the purposes of the NFIP. This definition is included in this chapter to clarify the applicability of any more stringent statewide floodplain management standards required under the FHACA. |
Permanent construction does not include land preparation, such as clearing, grading, and filling, nor does it include the installation of streets and/or walkways; nor does it include excavation for a basement, footings, piers, or foundations or the erection of temporary forms; nor does it include the installation on the property of accessory buildings, such as garages or sheds not occupied as dwelling units or not part of the main structure. Such development must also be permitted and must meet new requirements when National Flood Insurance Program (NFIP) maps are issued or revised and Base Flood Elevation's (BFEs) increase or zones change. |
For a substantial improvement, the actual start of construction means the first alteration of any wall, ceiling, floor, or other structural part of a building, whether or not that alteration affects the external dimensions of the building. |
For determining if new construction and substantial improvements within the Coastal Barrier Resources System (CBRS) can obtain flood insurance, a different definition applies. |
Exception. Where such equipment and appliances are designed and installed to prevent water from entering or accumulating within their components and the systems are constructed to resist hydrostatic and hydrodynamic loads and stresses, including the effects of buoyancy, during the occurrence of flooding up to the elevation required by Section 17:9-30.801.2, the systems and equipment shall be permitted to be located below that elevation. Electrical wiring systems shall be permitted below the design flood elevation provided they conform to the provisions of NFPA 70 (National Electric Code). |
Exception: Electrical systems, equipment and components, and heating, ventilating, air conditioning, and plumbing appliances, plumbing fixtures, duct systems, and other service equipment shall be permitted to be located below the Local Design Flood Elevation provided that they are designed and installed to prevent water from entering or accumulating within the components and to resist hydrostatic and hydrodynamic loads and stresses, including the effects of buoyancy, during the occurrence of flooding to the Local Design Flood Elevation in compliance with the flood-resistant construction requirements of ASCE 24. Electrical wiring systems shall be permitted to be located below the Local Design Flood Elevation provided they conform to the provisions of NFPA 70 (National Electric Code). |
Editor's Note: Schedule B, referred to herein may be found as an attachment to this chapter. |
Editor's Note: Schedule B, referred to herein may be found as an attachment to this chapter. |
Editor's Note: Ordinance No. MC 2002-29 which adopted this chapter was adopted December 2, 2002 and became effective December 22, 2002. |
Editor's Note: Ordinance No. MC 2002-29 which adopted this chapter was adopted December 2, 2002 and became effective December 22, 2002. |
TABLE OF PARKING REGULATIONS | ||
|---|---|---|
Use | Off-Street Parking Requirements | |
Residential | Single-family | See RSIS Standards |
Two-family | ||
Townhouse | ||
Apartment | ||
Art studio/art gallery | 1 space per 300 square feet of gross floor area | |
Assisted living facility | 1 space per 2.5 rooms | |
Automobile repair shop | 1 space per 300 square feet of gross floor area plus 3 spaces per work bay | |
Automobile service station | 1 space per two pumps or 4 spaces, whichever is greater | |
Automotive body shop | 2 spaces per bay and work area | |
Automotive dealership | 2.5 spaces per 1,000 square feet per gross floor area of interior sales space + 3 spaces per service bay | |
Bank | 1 space per 300 square feet of gross floor area | |
Banquet hall | 1 space per 3 persons based upon the maximum number of persons that can be accommodated at the same time in accordance with the design capacity of the structure under BOCA Regulations + 1 space for every two employees on the maximum shift | |
Bed and breakfast homestay | 1 space per guest room + 2 spaces per dwelling unit | |
Bed and breakfast guesthouse | 1 space per guest room + 1 space per employee + 2 spaces per dwelling unit | |
Car wash | 1 space per employee + 5 spaces per washing lane | |
Childcare facility | 1 space per employee but no less than 5 spaces | |
Community center | 4 spaces per 1,000 square feet of gross floor area | |
Community residence for the developmentally disabled | 1 space per employee | |
Family day care | 1 space per employee | |
Funeral home | 1 space per 200 square feet of gross floor area | |
Health club | 1 space per 75 square feet of gross floor area | |
Home Occupation | 1 space per employee + applicable RSIS requirements based on dwelling unit type | |
Hospital | 2 spaces per bed | |
Hotel | 1 space per guest room + 1 space per 2 employees + 1 space per 150 square feet of banquet and conference space | |
House of worship | 1 space per 4 seats; every two and one-half (2 1/2) feet (thirty (30) inches) of a pew measured horizontally shall be considered a seat | |
Laundromat | 1 space per 2 washer and dryer machines | |
Manufacturing and assembly | 1 space per 1,000 square feet of gross floor area | |
Medical office | 1 space per 175 square feet of gross floor area | |
Nightclub | 1 space per 3 persons based upon the maximum number of persons that can be accommodated at the same time in accordance with the design capacity of the structure under BOCA Regulations | |
Nursery and landscaping facility | No less than 3 spaces plus 1 space per 300 square feet of interior retail | |
Nursing home | 1 space per 3 resident rooms | |
Office | 1 space per 400 square feet of gross floor area | |
Personal service | 1 space per 300 square feet of gross floor area | |
Research | 1 space per 1,000 square feet of gross floor area | |
Restaurant | 1 space per 3 seats | |
Residential units in all TODD Zones | 1 parking space for each dwelling unit | |
Residential units in all TODN Zones | 1 parking space for each dwelling unit | |
Retail sales and service | 1 space per 300 square feet of gross floor area | |
Senior/Age Restricted Housing | 1 space for every three residential dwelling units | |
Tavern | 1 space per 2 seats | |
Theater | 1 space per 3 seats | |
Veterinary hospital | 1 space per 300 square feet of gross floor area | |
Warehouse & distribution facility | 1 space per 2,000 square feet of gross floor area | |
Dwelling Unit Type | Minimum Floor Area (square feet) |
|---|---|
Studio/Efficiency Apartment | 500 S.F. |
One (1) Bedroom Apartments | 750 S.F. |
Two (2) Bedroom Apartments | 1,000 S.F. |
Apartments with three (3) or more bedrooms | 1,100 S.F. + 150 S.F. per additional bedroom |
Zone | Minimum Floor Area (square feet) |
|---|---|
R-1 | 2,500 S.F. |
R-2 | 1,700 S.F. |
R-3 | 1,300 S.F. |
R-4 | 750 S.F. |
R-5 | 750 S.F. |
R-6 | 1,500 S.F. |
R-7 | 1,100 S.F. |
R-CA | 1,700 S.F. |
R-HA | 2,500 S.F. |
R-VWB | 2,500 S.F. (R-1 Zone); 1,700 S.F. (R-2 Zone) |
For subparagraphs a, b, c and d above, dwellings shall be deemed to be like each other in any dimension in which the difference between them is not more than six (6) feet. |
For subparagraph e above, dwellings shall be deemed to be like each other in any dimension in which the difference between them is not more than three (3) feet. |
For subparagraph f above, dwellings shall be deemed to be like each other if the difference between materials used is not more than thirty-five percent (35%) of the facade area. |
Dwellings between which the only difference in relative location of elements is end-to-end or side-to-side reversal of elements shall be deemed to be like each other in relative location of such elements. |
1. | Minimum Lot Area | 1 acre | ||
2. | Maximum Density | 50 dwelling units/acre | ||
3. | Minimum Lot Width | 150 feet (measured at arterial roadway right-of-way; 50 feet at all other roadways, if abutting) | ||
4. | Minimum Lot Depth | 200 feet | ||
5. | Minimum Front Yard Setback | 0 feet | ||
6. | Minimum Side Yard Setback | 10 feet adjacent to residential; 5 feet adjacent to commercial | ||
7. | Minimum Rear Yard Setback | 5 feet (except ingress/egress stairs can encroach into the rear yard provided at least a 3-foot setback is maintained) | ||
8. | Maximum Floor Area Ratio | 3.5 | ||
9. | Maximum Percent Building Cover | 75% | ||
10. | Maximum Percent Total Lot Cover | 90% | ||
11. | Minimum Number of Stories | 3 | ||
12. | Maximum Number of Stories | 5 | ||
13. | Maximum Building Height | 65 feet (Measured from the average elevation of the existing grade elevations found at the building corners) | ||
14. | Minimum Improvable Area | 32,000 square feet | ||
15. | Minimum Buffer Width When Abutting Residential Use | 5 feet (except ingress/egress stairs can encroach into the buffer provided at least a 3 foot buffer is maintained) | ||
16. | Minimum Driveway, Parking Area Buffer | 5 feet | ||
17. | Minimum Driveway Setback From Residential Use | 5 feet | ||
18. | Parking Stall Number | Four (4) stalls per 1,000 square feet of floor area dedicated to activity use where stand alone development is proposed. Where mixed use development is proposed, 1.5 stalls per dwelling unit. Shared parking to accommodate the needs of the nonresidential component is permitted provided each residential unit will have at least one dedicated parking space at all times. | ||
Tree Replacement Requirements Table | |||
|---|---|---|---|
Category | Tree Removed (DBH) | Tree Replacement Criteria | Application Fee |
1 | 6" (for non-street trees) to 12.99" | Replant 1 tree with a minimum tree caliper of 1.5" for each tree removed | $75 |
2 | DBH of 13" to 22.99" | Replant 2 trees with minimum tree calipers of 1.5" for each tree removed | $100 |
3 | DBH of 23" to 32.99" | Replant 3 trees with minimum tree calipers of 1.5" for each tree removed | $150 |
4 | DBH of 33" or greater | Replant 4 trees with minimum tree calipers of 1.5" for each tree removed | $175 |