Zoneomics Logo
search icon

Burr Ridge City Zoning Code

APPENDIX V

MINIMUM STANDARDS FOR PARKING STALLS, AISLES AND MODULES

MINIMUM STANDARDS FOR PARKING STALLS, AISLES AND MODULES

(See Diagram which follows)

On Diagram
Dimensions Based on the Angle of Parking
Angle of Parking
AThe angle of parking45o60o90o
BWidth of stall9'9'9'
CStall width, parallel to aisle12'9"10'5"9'
DStall depth, perpendicular to aisle20'21'18'
EStall length19'19'18'
FAisle width13'*17'*24'
GModules (Consist of two rows of parking stalls and one aisle

Interlock47'55'--

Wall to wall53'59'60'
* One way aisle only
**1.Exterior ramp grades shall not exceed 6o. Interior ramp grades shall not exceed 10o. Accessible ramp grades shall be 1” per 1’.
2. Where parallel parking is permitted, the stall length shall be 24 feet and aisle width shall be a minimum of 14 feet.
3. Parking space(s) for persons with disabilities shall be designed in accordance with State requirements.


HISTORY
Amended by Ord. A-834-13-25 on 8/25/2025

A-834-13-25