05 COMMERCIAL DISTRICTS
Table 17.05-1: Commercial District Dimensional Standards | ||||||
|---|---|---|---|---|---|---|
C-T | C-1 | C-2 | C-3 | C-C | C-OP | |
Bulk | ||||||
Minimum Lot Area | 10,000 square feet | None | None | 20,000 square feet | None | 20,000 square feet |
Minimum Lot Width | 60 feet | None | None | 80 feet | None | 70 feet |
Maximum Gross Floor Area of Nonresidential | 5,000 square feet unless meeting the standards of Section 17.05.030B | None | None | None | None | None |
Maximum Building Height | 35 feet | 45 feet | 45 feet | Non-residential: 55 feet Mixed-Use: 75 feet | None unless within 75 feet of a residential district, then 35 feet | 45 feet |
Setbacks | ||||||
Minimum Front Setback | Build-to zone of 0 feet to 20 feet | Build-to zone of 0 feet to 15 feet unless meeting the standards of Section 17.05.030C | None | 25 feet | None | 20 feet |
Front Setback Build-To Percentage | 70% | 70% | None | None | None | None |
Minimum Interior Side Setback | None, unless abutting a residential district then 20 feet | None, unless abutting a residential district then 10 feet | None, unless abutting a residential district then 10 feet | 10 feet, unless abutting a residential district then 20 feet | None, unless abutting a residential district, then 20 feet | 15 feet |
Minimum Corner Side Setback | Build-to zone of 0 feet to 15 feet | Build-to zone of 0 feet to 10 feet unless meeting the standards of Section 17.05.030C | 10 feet | 20 feet | None | Build-to zone of 0 feet to 20 feet |
Corner Side Setback Build-To Percentage | 60% | 60% | None | None | None | 60% |
Minimum Rear Setback | 15 feet, unless abutting a residential district then 25 feet or 20% of lot depth, whichever is less | None, unless abutting a residential district then 15 feet or 20% of lot depth, whichever is less | None, unless abutting a residential district then 15 feet | 10 feet, unless abutting a residential district then 25 feet | None, unless abutting a residential district, then 25 feet | 25 feet |
Table 17.05-2: Commercial District Design Standards | ||||||
|---|---|---|---|---|---|---|
C-T | C-1 | C-2 | C-3 | C-C | C-OP | |
Facade Design | ||||||
Building facades that face a public right-of-way, excluding alleys, must not contain blank wall areas that exceed 40 linear feet, measured parallel to the street | • | • | • | • | • | |
Building facades in excess of 100 linear feet that face a public right-of-way, excluding alleys, must include a repeating pattern with no less than 2 of the following elements: color change, texture change, building material change, or a wall articulation change of no less than 2 feet in depth or projection, such as a reveal, pilaster, or projecting rib. All elements must repeat at intervals of no more than 40 linear feet | • | • | • | • | • | |
Buildings with facades over 150 feet in length must incorporate wall projections or recesses, or changes in wall plane a minimum of 2 feet in depth a maximum of every 75 linear feet | • | |||||
All buildings must have a public entrance from the sidewalk along the primary building frontage. Public entrances must be visually distinctive from the remaining portions of the facade | • | • | • | • | • | |
Building materials and visual elements used on the facade of the primary building frontage must continue on all building facades that face a public right-of-way (excluding alleys) and/or the lot line of a residential district | • | • | • | • | • | |
Large expanses of highly reflective wall surface material and mirror glass on exterior walls are prohibited | • | • | • | • | • | • |
Fenestration Design | ||||||
The ground floor of a facade facing a public right-of-way (excluding alleys) must maintain a minimum transparency of 50%, measured between 2 and 10 feet in height from grade. | • | • | ||||
The ground floor of a facade facing a public right-of-way (excluding alleys) must maintain a minimum transparency of 35%, measured between 2 and 10 feet in height | • | • | ||||
Upper floors of a facade facing a public right-of-way (excluding alleys) must maintain a minimum transparency of 15% of the wall area of the story | • | • | • | |||
Roof Design | ||||||
Rooflines over 100 linear feet in building length must contain variation and incorporate a major focal point feature, such as a dormer, gable, or projected wall feature. An element of variegation on the roofline must occur at intervals of no more than 75 linear feet. | • | • | • | • | • | |
Parapet walls must feature three-dimensional cornice treatments or other shadow-creating details along their tops to provide visual interest | • | • | • | • | • | |
Any roof that is visible from a public right-of-way must be shingle or colored standing seam metal roofing | • | • | • | • | • | |
Green roof, blue roof, and white roof designs are encouraged | • | • | • | • | • | • |
Reflective roof surfaces that produce glare are prohibited, except for solar panels or white roofs intended to radiate absorbed or nonreflected solar energy and reduce heat transfer to the building | • | • | • | • | • | • |
Entrance Design | ||||||
Public entrances and primary building elevations must be oriented toward a public street. Main entrances to the buildings must be well defined. | • | |||||
Entries to office or guest facilities must address the street, with direct access to office or guest facilities from street frontages and parking areas | • | |||||
Multi-Tenant Commercial Center and Office Park Site Design | ||||||
Sites must be designed to ensure safe pedestrian access to the commercial center from the public right-of-way and safe pedestrian circulation within the development | • | • | • | • | ||
A cohesive character must be established through the use of coordinated hardscape (paving materials, lighting, street furniture, etc.) and landscape treatments within the development | • | • | • | • | ||
Commercial centers may provide definition along the street frontage by locating part of the center or outlot buildings within 0 feet to 25 feet of the front lot line. The center or any outlot buildings may be placed within a required setback to comply with this standard. | • | • | ||||
In multi-building complexes, a distinct visual link must be established between various buildings through the use of architectural features or site design elements such as courtyards, plazas, landscape, and walkways to unify the project | • | • | ||||
Developments should provide a pedestrian link to adjacent commercial uses to provide safe pedestrian access between the site and commercial uses outside the development | • | |||||
Table 17.05-3: C-D District Dimensional Standards | |
|---|---|
C-D | |
Bulk | |
Minimum Lot Area | None |
Minimum Lot Width | None |
Maximum Building Height | None |
Minimum Building Height | 24 feet |
Setbacks | |
Front Setback | 0 feet - 10 feet build-to zone |
Required Build-to Percentage | 80% |
Interior Side Setback | None |
Corner Side Setback | 0 feet - 10 feet build-to zone |
Rear Setback | None |
Table 17.05-4: C-V District Dimensional Standards | |
|---|---|
C-V | |
Bulk | |
Minimum Lot Area | None |
Minimum Lot Width | None |
Maximum Building Height | 45 feet |
Setbacks | |
Front Setback | 0 feet - 10 feet build-to-zone, or average of adjacent structures |
Required Build-to Percentage | 80% |
Interior Side Setback | None, unless abutting a residential district then 5 feet |
Corner Side Setback | 0 feet - 10 feet build-to zone |
Rear Setback | None, unless abutting a residential district then 25 feet |
Table 17.05-5: C-E District Dimensional Standards | |
|---|---|
Bulk | C-E |
Minimum Lot Area | 20,000 square feet |
Minimum Lot Width | 80 feet |
Maximum Building Height | 120 feet; 55 feet west and south of Elmore Avenue |
Minimum Setbacks | |
Front Setback | 25 feet |
Interior Side Setback | 10 feet, unless abutting a residential district, then 25 feet |
Corner Side Setback | 20 feet |
Rear Setback | 10 feet, unless abutting a residential district, then 25 feet |
05 COMMERCIAL DISTRICTS
Table 17.05-1: Commercial District Dimensional Standards | ||||||
|---|---|---|---|---|---|---|
C-T | C-1 | C-2 | C-3 | C-C | C-OP | |
Bulk | ||||||
Minimum Lot Area | 10,000 square feet | None | None | 20,000 square feet | None | 20,000 square feet |
Minimum Lot Width | 60 feet | None | None | 80 feet | None | 70 feet |
Maximum Gross Floor Area of Nonresidential | 5,000 square feet unless meeting the standards of Section 17.05.030B | None | None | None | None | None |
Maximum Building Height | 35 feet | 45 feet | 45 feet | Non-residential: 55 feet Mixed-Use: 75 feet | None unless within 75 feet of a residential district, then 35 feet | 45 feet |
Setbacks | ||||||
Minimum Front Setback | Build-to zone of 0 feet to 20 feet | Build-to zone of 0 feet to 15 feet unless meeting the standards of Section 17.05.030C | None | 25 feet | None | 20 feet |
Front Setback Build-To Percentage | 70% | 70% | None | None | None | None |
Minimum Interior Side Setback | None, unless abutting a residential district then 20 feet | None, unless abutting a residential district then 10 feet | None, unless abutting a residential district then 10 feet | 10 feet, unless abutting a residential district then 20 feet | None, unless abutting a residential district, then 20 feet | 15 feet |
Minimum Corner Side Setback | Build-to zone of 0 feet to 15 feet | Build-to zone of 0 feet to 10 feet unless meeting the standards of Section 17.05.030C | 10 feet | 20 feet | None | Build-to zone of 0 feet to 20 feet |
Corner Side Setback Build-To Percentage | 60% | 60% | None | None | None | 60% |
Minimum Rear Setback | 15 feet, unless abutting a residential district then 25 feet or 20% of lot depth, whichever is less | None, unless abutting a residential district then 15 feet or 20% of lot depth, whichever is less | None, unless abutting a residential district then 15 feet | 10 feet, unless abutting a residential district then 25 feet | None, unless abutting a residential district, then 25 feet | 25 feet |
Table 17.05-2: Commercial District Design Standards | ||||||
|---|---|---|---|---|---|---|
C-T | C-1 | C-2 | C-3 | C-C | C-OP | |
Facade Design | ||||||
Building facades that face a public right-of-way, excluding alleys, must not contain blank wall areas that exceed 40 linear feet, measured parallel to the street | • | • | • | • | • | |
Building facades in excess of 100 linear feet that face a public right-of-way, excluding alleys, must include a repeating pattern with no less than 2 of the following elements: color change, texture change, building material change, or a wall articulation change of no less than 2 feet in depth or projection, such as a reveal, pilaster, or projecting rib. All elements must repeat at intervals of no more than 40 linear feet | • | • | • | • | • | |
Buildings with facades over 150 feet in length must incorporate wall projections or recesses, or changes in wall plane a minimum of 2 feet in depth a maximum of every 75 linear feet | • | |||||
All buildings must have a public entrance from the sidewalk along the primary building frontage. Public entrances must be visually distinctive from the remaining portions of the facade | • | • | • | • | • | |
Building materials and visual elements used on the facade of the primary building frontage must continue on all building facades that face a public right-of-way (excluding alleys) and/or the lot line of a residential district | • | • | • | • | • | |
Large expanses of highly reflective wall surface material and mirror glass on exterior walls are prohibited | • | • | • | • | • | • |
Fenestration Design | ||||||
The ground floor of a facade facing a public right-of-way (excluding alleys) must maintain a minimum transparency of 50%, measured between 2 and 10 feet in height from grade. | • | • | ||||
The ground floor of a facade facing a public right-of-way (excluding alleys) must maintain a minimum transparency of 35%, measured between 2 and 10 feet in height | • | • | ||||
Upper floors of a facade facing a public right-of-way (excluding alleys) must maintain a minimum transparency of 15% of the wall area of the story | • | • | • | |||
Roof Design | ||||||
Rooflines over 100 linear feet in building length must contain variation and incorporate a major focal point feature, such as a dormer, gable, or projected wall feature. An element of variegation on the roofline must occur at intervals of no more than 75 linear feet. | • | • | • | • | • | |
Parapet walls must feature three-dimensional cornice treatments or other shadow-creating details along their tops to provide visual interest | • | • | • | • | • | |
Any roof that is visible from a public right-of-way must be shingle or colored standing seam metal roofing | • | • | • | • | • | |
Green roof, blue roof, and white roof designs are encouraged | • | • | • | • | • | • |
Reflective roof surfaces that produce glare are prohibited, except for solar panels or white roofs intended to radiate absorbed or nonreflected solar energy and reduce heat transfer to the building | • | • | • | • | • | • |
Entrance Design | ||||||
Public entrances and primary building elevations must be oriented toward a public street. Main entrances to the buildings must be well defined. | • | |||||
Entries to office or guest facilities must address the street, with direct access to office or guest facilities from street frontages and parking areas | • | |||||
Multi-Tenant Commercial Center and Office Park Site Design | ||||||
Sites must be designed to ensure safe pedestrian access to the commercial center from the public right-of-way and safe pedestrian circulation within the development | • | • | • | • | ||
A cohesive character must be established through the use of coordinated hardscape (paving materials, lighting, street furniture, etc.) and landscape treatments within the development | • | • | • | • | ||
Commercial centers may provide definition along the street frontage by locating part of the center or outlot buildings within 0 feet to 25 feet of the front lot line. The center or any outlot buildings may be placed within a required setback to comply with this standard. | • | • | ||||
In multi-building complexes, a distinct visual link must be established between various buildings through the use of architectural features or site design elements such as courtyards, plazas, landscape, and walkways to unify the project | • | • | ||||
Developments should provide a pedestrian link to adjacent commercial uses to provide safe pedestrian access between the site and commercial uses outside the development | • | |||||
Table 17.05-3: C-D District Dimensional Standards | |
|---|---|
C-D | |
Bulk | |
Minimum Lot Area | None |
Minimum Lot Width | None |
Maximum Building Height | None |
Minimum Building Height | 24 feet |
Setbacks | |
Front Setback | 0 feet - 10 feet build-to zone |
Required Build-to Percentage | 80% |
Interior Side Setback | None |
Corner Side Setback | 0 feet - 10 feet build-to zone |
Rear Setback | None |
Table 17.05-4: C-V District Dimensional Standards | |
|---|---|
C-V | |
Bulk | |
Minimum Lot Area | None |
Minimum Lot Width | None |
Maximum Building Height | 45 feet |
Setbacks | |
Front Setback | 0 feet - 10 feet build-to-zone, or average of adjacent structures |
Required Build-to Percentage | 80% |
Interior Side Setback | None, unless abutting a residential district then 5 feet |
Corner Side Setback | 0 feet - 10 feet build-to zone |
Rear Setback | None, unless abutting a residential district then 25 feet |
Table 17.05-5: C-E District Dimensional Standards | |
|---|---|
Bulk | C-E |
Minimum Lot Area | 20,000 square feet |
Minimum Lot Width | 80 feet |
Maximum Building Height | 120 feet; 55 feet west and south of Elmore Avenue |
Minimum Setbacks | |
Front Setback | 25 feet |
Interior Side Setback | 10 feet, unless abutting a residential district, then 25 feet |
Corner Side Setback | 20 feet |
Rear Setback | 10 feet, unless abutting a residential district, then 25 feet |