80 LAND USE ZONES
Table 2: Comprehensive Plan/Zoning District Matrix | |
|---|---|
Comprehensive Plan Designation | Zoning District Classification |
Residential Low | Residential 1 (R-1) |
Residential Moderate | Residential 2 (R-2) |
Mixed Residential Low | Mixed Residential 1 (MR-1) |
Mixed Residential Moderate | Mixed Residential 2 (MR-2) |
Mixed Use Residential | Mixed Use Residential (MUR) |
Commercial | Commercial (C) |
Town Center | Town Center (TC) |
Public | Public (P) |
Business Park | Business Park (BP) |
Industrial | Industrial (I) |
Table 1: Development Standards | ||||
|---|---|---|---|---|
Standards | TC | C | MUR | BP |
Maximum Height (without Any Bonus) (1) | 45 feet | 35 feet | 35 feet | 35 feet |
Maximum Height (with FAR Bonus) (1) | 57 feet (minimum 3:1 FAR) | 45 feet (minimum 1.5:1 FAR) | 35 feet | 35 feet |
Maximum Residential Net Density – Single-Use Project (3)(5)(14) | 48 D.U./acre | N/A (1) | 24 D.U./acre | N/A (1) |
Maximum Residential Net Density – If Part of a Mixed Use Project (2)(4)(5)(14) | Controlled by maximum height, FAR and building code | 48 D.U./acre | 48 D.U./acre | N/A (1) |
Minimum Residential Net Density (5)(6) | 24 D.U./acre | N/A (1) | 10 D.U./acre | N/A |
Minimum Lot Frontage Occupied by a Building (7) | 50% | 35% | 35% | None |
Minimum Setback to TC, C, MUR or BP Zones (8) | None | None | None (9) | None, except 20 feet for light industrial |
Minimum Setbacks to Zones Other Than TC, C, MUR or BP (10) | 25 feet | 25 feet | 20 feet | 25 feet |
Maximum Floor Area Ratio (FAR) with Bonus Features (11) | 4:1 | 3:1 | 2:1 (12) | 2:1 |
Maximum Floor Area Ratio (FAR) without Bonus Features (13) | 1:1 | 0.5:1 | 0.5:1 (12) | 0.5:1 |
Maximum Hard Surface Area (Including Lot Coverage) | 90% | 85% | 75% | 80% |
Maximum Effective Impervious Surface | 75% | 70% | 60% | 65% |
Table 1: Development Standards Exceptions and Notes. | |
(1) Multifamily use in BP zones requires a CUP and is limited to multifamily as allowed. Residential use only allowed in Commercial zone if part of mixed use project. | |
(2) To qualify for mixed use bonus, uses must be developed in same project either as vertical or horizontal mixed use. | |
(3) Residential single-use project proposals within the TC, and C zones on combined project areas three acres or larger, shall set back single-use residential structures 150 feet from an arterial ROW line. The setback area shall develop, at minimum, 30 percent of the area into retail- or office-type commercial uses or preserved for future retail- or office-type commercial uses. The remaining area within the first 150 feet from an arterial ROW may be developed into residential uses. | |
(4) Mixed use development projects demonstrating a mix (30 percent commercial minimum) of residential and commercial within the same design may be located throughout the property and not limited to any portion of any specific property. | |
(5) Vertical mixed use projects with ground floor commercial space may be constructed as fully residential projects with the requirement that the ground floor must be converted to a commercial use within three years of building occupancy. Notice to title shall be recorded prior to permit issuance if this provision is requested. | |
(6) Minimum density only applies for single-use residential projects. | |
(7) For building lots fronting directly on Meridian the minimum lot frontage occupied by a building in all zones is 35 percent. | |
(8) Setbacks may be necessary to accommodate utility easements or to accommodate required landscaping. | |
(9) Setbacks for single-family detached dwellings shall be as follows: | |
(a) Front yard/street setback: 15 feet. | |
(b) Garage setback: 20 feet. | |
(c) Principal arterial and state highway setback: 25 feet. | |
(d) Rear yard setback: 10 feet. | |
(e) Interior setback: five feet or shall meet the minimum fire separation required per the International Fire Code (IFC) as adopted by the city of Edgewood. | |
(10) Twenty-foot setback required from any public property other than a street. | |
(11) See Table 2: Development Intensity Bonus Options necessary to achieve maximum FAR. | |
(12) FAR does not apply to single-family detached dwelling or cottage housing. | |
(13) There is no minimum FAR in the TC, C, MUR or BP zones. | |
(14) Director and city engineer may establish administrative rules for allowing partial credit for pervious paving materials. | |
Table 2: Development Intensity Bonus Options | ||
|---|---|---|
Bonus Feature | FAR Bonus | Description, Additional Requirements and Limitations |
1. Parallel Road Network | 1.5 | Dedication and construction of those portions of the adopted parallel road network that are within or adjacent to the subject property. Design shall be consistent with the adopted street standards, including, but not limited to, travel lanes, on-street parking, landscaping and sidewalk. |
2. Significant Public Plaza or Public Green Space | 1.25 | Available in the Town Center district only, and at the discretion of the director. Location and design shall be consistent with Town Center and Meridian Avenue Corridor master plan, and, if possible, complementary to any planned public plaza or development. Must be a minimum of five percent of the interior floor area of the development and no less than 1,500 square feet. This bonus must be in addition to any pedestrian-oriented space as required in subsection (F) of this section and EMC § 18.95.030 or as required by any underlying land use approval. Plazas and green spaces shall incorporate LID to the maximum extent feasible (per Minimum Requirement No. 5 of the PCM). |
3. Through Block Connection or Alley Enhancement | 1.0 | A pedestrian walkway and accompanying landscaping that shall be at least 15 feet wide and extend along a property line or through a site to allow the public to pass from one street to another street or an alley. The surface shall consist of stone, unit pavers, textured concrete, permeable pavement, or other material approved by the community development director or designee, with pedestrian scale lighting at least every 50 feet. Walkways and landscaping shall incorporate LID to the maximum extent feasible (per Minimum Requirement No. 5 of the PCM). |
4. Mixed Use Development | 1.0 | Ground floor commercial with minimum of 12 feet in height measured from finished floor to finished ceiling and residential uses on upper floors at or above minimum residential density. Note additional required standards for pedestrian-oriented ground floor commercial in No. 8 below shall also apply. |
5. Structure Parking, Below Grade | 1.0 | At least 80 percent of the parking shall be contained within a structure that is below grade. |
6. Affordable Housing | 1.0 | For all new development within the Town Center, total square footage may be increased by two square feet for every one square foot of affordable housing (for a maximum of 1.0 FAR in bonus) provided an affordable housing plan (AHP) is developed and submitted to the director for review and approval. The developer shall commit to implementing the AHP as a part of a signed comprehensive development agreement with the city. This agreement shall be reviewed by a housing consultant or nonprofit group at the expense of the applicant with recommendations made to the director prior to any city commitment to that agreement. |
7. Other Public Plaza or Public Green Space | 0.75 | Location and design shall be consistent with Town Center and Meridian Avenue Corridor master plan and any planned public plaza or development. Must be a minimum of two percent of the interior floor area of the development and no less than 500 square feet. This bonus must be in addition to the minimum pedestrian-oriented space requirement in subsection (F) of this section and EMC § 18.95.030. Plazas and green spaces shall incorporate LID to the maximum extent feasible (per Minimum Requirement No. 5 of the PCM). |
8. Ground Floor Pedestrian-Oriented Commercial | 0.75 | Ground floor commercial with minimum of 12 feet in height measured from finished floor to finished ceiling. Buildings shall include windows with clear vision glass on at least 50 percent of the area between two and 12 feet above grade for all ground floor building facades that are visible from an abutting street. Weather protection with a minimum of six feet in depth shall be provided over sidewalks and pedestrian connections on 80 percent of the length of the building frontage. This bonus feature may not be used in conjunction with No. 3 above. |
9. Structured Parking, At Grade or Above Grade | 0.75 | At least 80 percent of the parking shall be contained within a structure. The structure may be part of the building or a separate structure. The structure shall be designed to minimize visibility of the parking area from the street. The street level floor shall be mixed use. |
10. LEED Gold Certification (or Better) | 0.75 | As certified by the USGBC. Applicant is responsible for providing LEED precertification submittal documentation and annotated checklist to the city. City will review documentation at the applicant's expense. If accepted, the city will make this a condition of approval of the subsequent building permit. |
11. Multi-Modal Pathway | 0.5 | A pathway for the movement of pedestrians and bicyclists that is consistent with the Town Center and Meridian Avenue Corridor master plan, transportation plan, and city's parks and recreation plan and approved by city staff. Pathways shall incorporate LID to the maximum extent feasible (per Minimum Requirement No. 5 of the PCM). |
12. Public Meeting Room | 0.5 | Available in the Town Center district only. A room available to the community for meetings and events. The size shall be a minimum of 500 square feet, with windows on at least one side and shall be directly accessible from the outside or by a controlled lobby that allows public access. |
13. LEED Silver Certification | 0.5 | As certified by the USGBC. Applicant is responsible for providing LEED precertification submittal documentation and annotated checklist to the city. City will review documentation at the applicant's expense. If accepted, the city will make this a condition of approval of the subsequent building permit. |
14. Water Feature | 0.25 | A decorative water feature shall be equivalent to at least one percent of the project's construction cost and shall be directly accessible and visible to the public by being adjacent to a plaza, sidewalk, pathway or through-block connection. Documentation shall be provided of construction value and the cost of the water feature. |
15. Exterior Art Element | 0.25 | Exterior art element shall be equivalent to at least one percent of the total value of the project's construction cost. Such elements include but are not limited to sculptures, bas-reliefs, metalwork and murals. Documentation shall be provided of the construction value and the value of the art as appraised by an art appraiser. Art elements shall be visible to the public at all times and will be reviewed and approved by an arts body designated by the city. |
80 LAND USE ZONES
Table 2: Comprehensive Plan/Zoning District Matrix | |
|---|---|
Comprehensive Plan Designation | Zoning District Classification |
Residential Low | Residential 1 (R-1) |
Residential Moderate | Residential 2 (R-2) |
Mixed Residential Low | Mixed Residential 1 (MR-1) |
Mixed Residential Moderate | Mixed Residential 2 (MR-2) |
Mixed Use Residential | Mixed Use Residential (MUR) |
Commercial | Commercial (C) |
Town Center | Town Center (TC) |
Public | Public (P) |
Business Park | Business Park (BP) |
Industrial | Industrial (I) |
Table 1: Development Standards | ||||
|---|---|---|---|---|
Standards | TC | C | MUR | BP |
Maximum Height (without Any Bonus) (1) | 45 feet | 35 feet | 35 feet | 35 feet |
Maximum Height (with FAR Bonus) (1) | 57 feet (minimum 3:1 FAR) | 45 feet (minimum 1.5:1 FAR) | 35 feet | 35 feet |
Maximum Residential Net Density – Single-Use Project (3)(5)(14) | 48 D.U./acre | N/A (1) | 24 D.U./acre | N/A (1) |
Maximum Residential Net Density – If Part of a Mixed Use Project (2)(4)(5)(14) | Controlled by maximum height, FAR and building code | 48 D.U./acre | 48 D.U./acre | N/A (1) |
Minimum Residential Net Density (5)(6) | 24 D.U./acre | N/A (1) | 10 D.U./acre | N/A |
Minimum Lot Frontage Occupied by a Building (7) | 50% | 35% | 35% | None |
Minimum Setback to TC, C, MUR or BP Zones (8) | None | None | None (9) | None, except 20 feet for light industrial |
Minimum Setbacks to Zones Other Than TC, C, MUR or BP (10) | 25 feet | 25 feet | 20 feet | 25 feet |
Maximum Floor Area Ratio (FAR) with Bonus Features (11) | 4:1 | 3:1 | 2:1 (12) | 2:1 |
Maximum Floor Area Ratio (FAR) without Bonus Features (13) | 1:1 | 0.5:1 | 0.5:1 (12) | 0.5:1 |
Maximum Hard Surface Area (Including Lot Coverage) | 90% | 85% | 75% | 80% |
Maximum Effective Impervious Surface | 75% | 70% | 60% | 65% |
Table 1: Development Standards Exceptions and Notes. | |
(1) Multifamily use in BP zones requires a CUP and is limited to multifamily as allowed. Residential use only allowed in Commercial zone if part of mixed use project. | |
(2) To qualify for mixed use bonus, uses must be developed in same project either as vertical or horizontal mixed use. | |
(3) Residential single-use project proposals within the TC, and C zones on combined project areas three acres or larger, shall set back single-use residential structures 150 feet from an arterial ROW line. The setback area shall develop, at minimum, 30 percent of the area into retail- or office-type commercial uses or preserved for future retail- or office-type commercial uses. The remaining area within the first 150 feet from an arterial ROW may be developed into residential uses. | |
(4) Mixed use development projects demonstrating a mix (30 percent commercial minimum) of residential and commercial within the same design may be located throughout the property and not limited to any portion of any specific property. | |
(5) Vertical mixed use projects with ground floor commercial space may be constructed as fully residential projects with the requirement that the ground floor must be converted to a commercial use within three years of building occupancy. Notice to title shall be recorded prior to permit issuance if this provision is requested. | |
(6) Minimum density only applies for single-use residential projects. | |
(7) For building lots fronting directly on Meridian the minimum lot frontage occupied by a building in all zones is 35 percent. | |
(8) Setbacks may be necessary to accommodate utility easements or to accommodate required landscaping. | |
(9) Setbacks for single-family detached dwellings shall be as follows: | |
(a) Front yard/street setback: 15 feet. | |
(b) Garage setback: 20 feet. | |
(c) Principal arterial and state highway setback: 25 feet. | |
(d) Rear yard setback: 10 feet. | |
(e) Interior setback: five feet or shall meet the minimum fire separation required per the International Fire Code (IFC) as adopted by the city of Edgewood. | |
(10) Twenty-foot setback required from any public property other than a street. | |
(11) See Table 2: Development Intensity Bonus Options necessary to achieve maximum FAR. | |
(12) FAR does not apply to single-family detached dwelling or cottage housing. | |
(13) There is no minimum FAR in the TC, C, MUR or BP zones. | |
(14) Director and city engineer may establish administrative rules for allowing partial credit for pervious paving materials. | |
Table 2: Development Intensity Bonus Options | ||
|---|---|---|
Bonus Feature | FAR Bonus | Description, Additional Requirements and Limitations |
1. Parallel Road Network | 1.5 | Dedication and construction of those portions of the adopted parallel road network that are within or adjacent to the subject property. Design shall be consistent with the adopted street standards, including, but not limited to, travel lanes, on-street parking, landscaping and sidewalk. |
2. Significant Public Plaza or Public Green Space | 1.25 | Available in the Town Center district only, and at the discretion of the director. Location and design shall be consistent with Town Center and Meridian Avenue Corridor master plan, and, if possible, complementary to any planned public plaza or development. Must be a minimum of five percent of the interior floor area of the development and no less than 1,500 square feet. This bonus must be in addition to any pedestrian-oriented space as required in subsection (F) of this section and EMC § 18.95.030 or as required by any underlying land use approval. Plazas and green spaces shall incorporate LID to the maximum extent feasible (per Minimum Requirement No. 5 of the PCM). |
3. Through Block Connection or Alley Enhancement | 1.0 | A pedestrian walkway and accompanying landscaping that shall be at least 15 feet wide and extend along a property line or through a site to allow the public to pass from one street to another street or an alley. The surface shall consist of stone, unit pavers, textured concrete, permeable pavement, or other material approved by the community development director or designee, with pedestrian scale lighting at least every 50 feet. Walkways and landscaping shall incorporate LID to the maximum extent feasible (per Minimum Requirement No. 5 of the PCM). |
4. Mixed Use Development | 1.0 | Ground floor commercial with minimum of 12 feet in height measured from finished floor to finished ceiling and residential uses on upper floors at or above minimum residential density. Note additional required standards for pedestrian-oriented ground floor commercial in No. 8 below shall also apply. |
5. Structure Parking, Below Grade | 1.0 | At least 80 percent of the parking shall be contained within a structure that is below grade. |
6. Affordable Housing | 1.0 | For all new development within the Town Center, total square footage may be increased by two square feet for every one square foot of affordable housing (for a maximum of 1.0 FAR in bonus) provided an affordable housing plan (AHP) is developed and submitted to the director for review and approval. The developer shall commit to implementing the AHP as a part of a signed comprehensive development agreement with the city. This agreement shall be reviewed by a housing consultant or nonprofit group at the expense of the applicant with recommendations made to the director prior to any city commitment to that agreement. |
7. Other Public Plaza or Public Green Space | 0.75 | Location and design shall be consistent with Town Center and Meridian Avenue Corridor master plan and any planned public plaza or development. Must be a minimum of two percent of the interior floor area of the development and no less than 500 square feet. This bonus must be in addition to the minimum pedestrian-oriented space requirement in subsection (F) of this section and EMC § 18.95.030. Plazas and green spaces shall incorporate LID to the maximum extent feasible (per Minimum Requirement No. 5 of the PCM). |
8. Ground Floor Pedestrian-Oriented Commercial | 0.75 | Ground floor commercial with minimum of 12 feet in height measured from finished floor to finished ceiling. Buildings shall include windows with clear vision glass on at least 50 percent of the area between two and 12 feet above grade for all ground floor building facades that are visible from an abutting street. Weather protection with a minimum of six feet in depth shall be provided over sidewalks and pedestrian connections on 80 percent of the length of the building frontage. This bonus feature may not be used in conjunction with No. 3 above. |
9. Structured Parking, At Grade or Above Grade | 0.75 | At least 80 percent of the parking shall be contained within a structure. The structure may be part of the building or a separate structure. The structure shall be designed to minimize visibility of the parking area from the street. The street level floor shall be mixed use. |
10. LEED Gold Certification (or Better) | 0.75 | As certified by the USGBC. Applicant is responsible for providing LEED precertification submittal documentation and annotated checklist to the city. City will review documentation at the applicant's expense. If accepted, the city will make this a condition of approval of the subsequent building permit. |
11. Multi-Modal Pathway | 0.5 | A pathway for the movement of pedestrians and bicyclists that is consistent with the Town Center and Meridian Avenue Corridor master plan, transportation plan, and city's parks and recreation plan and approved by city staff. Pathways shall incorporate LID to the maximum extent feasible (per Minimum Requirement No. 5 of the PCM). |
12. Public Meeting Room | 0.5 | Available in the Town Center district only. A room available to the community for meetings and events. The size shall be a minimum of 500 square feet, with windows on at least one side and shall be directly accessible from the outside or by a controlled lobby that allows public access. |
13. LEED Silver Certification | 0.5 | As certified by the USGBC. Applicant is responsible for providing LEED precertification submittal documentation and annotated checklist to the city. City will review documentation at the applicant's expense. If accepted, the city will make this a condition of approval of the subsequent building permit. |
14. Water Feature | 0.25 | A decorative water feature shall be equivalent to at least one percent of the project's construction cost and shall be directly accessible and visible to the public by being adjacent to a plaza, sidewalk, pathway or through-block connection. Documentation shall be provided of construction value and the cost of the water feature. |
15. Exterior Art Element | 0.25 | Exterior art element shall be equivalent to at least one percent of the total value of the project's construction cost. Such elements include but are not limited to sculptures, bas-reliefs, metalwork and murals. Documentation shall be provided of the construction value and the value of the art as appraised by an art appraiser. Art elements shall be visible to the public at all times and will be reviewed and approved by an arts body designated by the city. |