Town Center TC-1 Zoning District
Figure 20-1: Gordon Avenue & Highway 89 Town Center Regulatory Plan

Table 30-1
Uses
Sub-Districts
Commercial
Mixed-Use
Town Residential
Neighborhood Residential
Detached Residential
Open Space
Residential/Domestic
Accessory Dwelling Unit, Internal (IADU)
P
Dwelling, Multiple Unit
D
P
D
Dwelling, 2 Unit
P
Dwelling, 1 Unit
P
Household Pets
P
P
P
P
Off-Street Parking Inc. to Main Use
P
P
P
P
P
P
Model Home
P
P
P
P
Temporary Sales Office
D
D
D
D
D
Institutional/Civic and Special Services
Community Center
P
P
P
Community Use
P
P
P
P
P
Day Care Center
P
D
Religious or Philanthropic Institution
P
P
P
P
P
P
Library, Art Gallery, Museum
P
P
P
Park and/or Playground
D
D
D
D
D
P
Private/Quasi-Public School
P
P
P
P
Utility Related Services
Local Utility Distribution Line
P
P
P
P
P
P
Radio, TV, or Microwave Tower
D
D
Sewage/Water Pumping/Control Station
P
P
P
P
P
P
Telecommunications Antenna, Roof Mounted
P
P
P
P
Telecommunications Antenna, Wall Mounted
P
P
Telephone Business Office
P
P
Water Wells, Reservoir, or Storage Tank
P
P
P
P
P
P
Recreational Uses
Indoor Commercial Amusement
P
P
Outdoor Commercial Amusement
P
Athletic Center; and
Sports Facility/Complex
D
P
P
Theater, Indoor
D
D
Theater, Live
D
D
Theater, Outdoor
P
Agriculture and Related Uses
Family Food Production
P
P
P
Automobile, Industrial and Related Uses
Gasoline Retail (No Repairs)
D
New & Reconditioned Auto Parts, Indoor
D
Retail and Related Uses
Bank, Credit Union, or Savings & Loan with Drive-through
D
D
Bank or Credit Union without Drive-through
P
P
Barber or Beauty Shop
P
P
Convenience Store (No Gasoline Sales)
P
P
Fast Food Eating Establishment
D
D
Grocery Store
P
Laundromat
P
P
Music Store
P
P
Office, Professional or General Business
P
P
Restaurant
P
P
Retail Sales and Commercial Services
P
P
Studio – Art, Photo
P
P
Studio – Health, Exercise, Dance, Music, Drama, or Similar
D
D
Commercial and Related Services
Bakery
P
P
Food Cart, Food Truck
D
D
Kiosk
P
P
Medical/Dental Clinic
P
P
Permanent Cosmetics
P
P
Pre-School
D
Seasonal Outdoor Vendor
D
D
Single Event
P
P
Street Vendor
D
D

Table 40-1 Permitted Building Types by Sub-district
Sub-Districts
Commercial Core
Mixed-Use Core
Town Residential
Neighborhood Residential
Detached Residential
Building Types
Commercial
P
P
Office
P
P
Mixed-Use
Commercial
P
P
Mixed-Use Residential
P
Townhouse
P
Mansion Style
P
P
Twin Home
P
Single-Family Detached
P
a. Commercial Building. The Commercial building type is intended to provide a wide range of uses from corner stores, restaurants, to larger stores such as a grocer. The building is oriented towards street frontages and provided with a high level of transparency along with enhanced identification for primary entrances. Locating this building along front and corner property lines provides greater access for pedestrians in the town center. Parking may be provided to the side or rear of the building or internally within the building with convenient access to the primary building entrance and other entrances as needed. Larger commercial buildings, such as a grocer, may orient towards a centralized parking area that is shared with multiple commercial buildings. Development and design standards for this building type vary based on the sub-district in which it is located. (See Appendix 40-A)
b. Office Building. The Office building type is intended to provide a location for professional office uses that contribute to the daytime vibrancy of the town center. Office buildings may be located adjacent to residential or commercial developments and include shared-use parking with those adjacent uses. (See Appendix 40-A)
c. Mixed-Use Commercial Building. The Mixed-Use Commercial building type is intended to provide a mix of commercial uses such as offices and retail or services within a single building. The different types of uses will provide daytime and evening vibrancy for the town center, with an employment population during business hours and continued retail or service use into evening hours. This building type may be located adjacent to residential or commercial developments and include shared-use parking with those uses. (See Appendix 40-A)
d. Mixed-Use Residential Building. The Mixed-Use Residential building type is intended to provide a location for residential units and a mix of commercial uses such retail or services uses in a single building. This building type will provide vibrancy for the town center, with an active resident and commercial population throughout the day. (See Appendix 40-A)
e. Townhome Building. The Townhome building type is intended to provide a location for residential units that will support the retail or services uses of the commercial and mixed-use areas of the town center. The proximity of the townhome residential uses to the commercial and mixed-use area will help create a vibrant and walkable town center. This building type may also include live/workspaces on the ground level of individual units. (See Appendix 40-B)
f. Mansion Style Building. The Mansion Style building type is intended to look like a larger home while providing multi-family housing on a scale that is low to moderate and compatible with adjacent single-family detached or attached housing. The Mansion Style building type provides a transition from higher density mixed-use housing to the outer edges of the town center. (See Appendix 40-C)
g. Twin Home Building. The Twin Home building type is intended to provide low density multi-family housing on a scale that is compatible with adjacent single-family detached or attached housing. The Twin Home style building type provides an additional transition from higher density mixed-use housing to the outer edges of the town center. The general building height is typically two stories. (See Appendix 40-D)
h. Single-Family Detached. The Single-Family Detached building type is intended to provide a medium density single-family detached option on the periphery of the town center and as a transition to the established single-family neighborhoods. This building type will allow single-family homes similar to those in surrounding neighborhoods but on smaller lots. The general building height is typically two stories. (See Appendix 40-E)
Table 40-2 Commercial, Office, Mixed-Use Commercial, and Mixed-Use Residential Building Standards
Commercial
Office and
Mixed-Use Commercial
Mixed-Use Residential
Property and Building Location Standards
Front Property Line Coverage
60%
60%
80%
Front Build-to Zone
with Plaza or Main Entry Canopy
0'-15'
Up to 25'
0'-20'
Up to 30'
0'-10'
Up to 20'
Corner Build-to Zone
0'-15'
0'-20'
0'-10'
Occupation of Corner
Required
Minimum Side Yard Setback
0'
5'
0'
Minimum Rear Yard Setback
5'
10'
5'
Site Access & Parking
Parking and Loading Location
Rear or Interior Side Yard
Vehicular Access
1 access is permitted per Public Works or UDOT Standards
Building Massing
Minimum Overall Height
2 Stories1
Maximum Overall Height
3 Stories
Ground Story: Min. / Max. Height
12' / 24'
12'/18'
Upper Stories: Min. / Max. Height
9'/14'
Permitted Roof Types
Roof type shall be consistent with the architectural style of the building and in accordance with Section 19.28.050.1.k
Tower
Permitted, Required at Street Corners
Permitted
Façade Articulation/Details
Blank Wall Limitations
Per Section 19.28.050.1.f
Vertical Façade Divisions
Every 25' of façade width
Horizontal Façade Divisions
Required within 3’ of the top of the ground story or at the base of the uppermost story
Front Façade Entrance
Covered
Building Entrance
Principal Entrance Location
Front or Corner Façade
Residential: Rear or Side
Commercial: Front or Side
Required Number of Street Entrances
1 per 150' of front façade or per unit.
1 per 100' of front façade
1 per 75'of front façade
Uses
Parking within Building
Permitted fully in basement; Or to rear of all floors beyond required occupied space
Required Occupied Space
35' (See Section 19.28.050.1.j)
1Reduced minimum height standards may be considered as part of a Development Agreement.
Table 40-3 Mansion, Twin Home, and Townhouse Building Standards
Mansion Style
Twin Home
Townhouse
Property and Building Location Standards
Front Property Line Coverage
70%
70%
Minimum Unit Width
Not Required
20’
Maximum # Units per Building
4 Units
2 Units
6 Units
Front Build-to Zone
12'-20'
12'-20' (Street Facing)
10'-20' (Open Space Facing)
Front to Front Separation
30'
30'
30'
Front Orientation
To a street or open space2,3
Corner Build-to Zone
12'-20'
8'-20'
12'-20'
Occupation of Corner
Not Required
Required
Minimum Side Yard Setback
5'
Minimum Rear Yard Setback
10'
Access & Parking
Parking and Loading Location
Rear or Interior Side
Vehicular Access
Rear-loaded from Alley3
Building Massing
Minimum Overall Height
2 Stories
Maximum Overall Height
3 Stories; 2 Stories at Corner
3 Stories
3 Stories; 2 Stories at Corner
Permitted Roof Types
Roof type shall be consistent with the architectural style of the building1
Tower
Permitted
Façade Articulation/Details
Blank Wall Limitations
Per Section 19.28.050.1.f
Vertical Façade Divisions
Not Required
Required Between Units
1Flat roofs are permitted as an accent or secondary roof and not the primary roof form.
2Fronting open space is only permitted when another row of townhouses is located on the opposite side of the open space which has a minimum width of 20' and that extends the length of the units.
3Front-loaded townhouses are permitted when units are unable to front a street and/or open space and shall comply with the following requirements: (1) shall include a private fenced backyard that measures the width of each unit and has a minimum depth of 20'. (2) A five foot sidewalk shall be provided along each frontage that connects the main entrance of the units to a public sidewalk and internal pathway network; (3) Development Plan shall include a snow storage plan and trash receptacle plan; (4) the Community & Economic Development Director may require each unit to have 18'-20' driveways.
Table 40-4 Single-Family Detached Building Type Standards1
Detached Residential
Property and Building Location Standards
Minimum Property Size
4,000 square feet
Maximum Property Size
6,500 square feet
Maximum Impervious Coverage
See Tables in LMC Chapter 19.05
Front Property Line Coverage
50%
Front Build-to Zone
20'-30'
Corner Side Yard Setback
20'
Minimum Side Yard Setback
6'
Minimum Rear Yard Setback
25'
Site Access & Parking
Parking and Loading Location
See Chapter LMC 19.12
Vehicular Access
Building Massing
Minimum Overall Height
1 Story
Maximum Overall Height
2 Stories & 35'
Ground Story: Min. / Max. Height
8' / 14'
Upper Story: Min. / Max. Height
8' / 12'
Permitted Roof Types
Roof type shall be consistent with the architectural style of the building2
Façade Articulation/Details
Blank Wall Limitations
Per Section 19.28.050.1.f
Vertical Façade Divisions
Not Required
1Shall comply with all development standards of Title 19 not otherwise addressed herein.
2Flat roofs are permitted as an accent or secondary roof and not the primary roof form.
1. General Building Type Standards. The following standards apply to all commercial, office, and mixed-use buildings within the TC-1 zone:
a. Permanent Structures. All buildings shall be of permanent construction without chassis, hitch, or wheels, or other features which would make the structure mobile.
b. All build-to-zone and setback areas not covered by a building must contain landscaping, patio space and/or pathway space.
c. Transition Setbacks. To provide compatibility with adjacent lower density neighborhoods, additional setback distances and height transitions shall be required for the properties directly adjacent to these neighborhoods. (See Figure 50-1)
i. Distance Transition. Any building type adjacent to a single-family residential zone shall have a minimum 20' setback from the adjacent lot.
ii. Height Transition. The maximum height for a building less than 30' from the property line shared with a property that is residentially zoned shall be 28' and no greater than two stories. The height can transition beginning at 30' from the property line, with one foot of additional building height allowed for every two feet in additional horizontal distance from the property line.
d. Minimum and Maximum Number of Stories. Each building shall comply with the minimum and maximum number of stories permitted per building type.
i. Half-Stories. Buildings may include a half-story within the roof structure or a half-story as part of a visible basement. A building incorporating both a half story within the roof and a half-story as part of a visible basement shall count the combined total of both half-stories as one full story.
ii. To allow for atriums, vaulted ceilings, or upper clerestories, full stories may exceed the maximum height as specified by building type but shall be counted as two or more stories.

e. Primary and Secondary Building Entrances
i. Buildings with frontage on a public street shall provide a clear identifiably primary entrance oriented towards and directly accessible from the public street. The primary entrance shall be designed and maintained as the principal point of customer access and shall remain functional at all times the tenant space is open to the public.
ii. Secondary entrances may be provided on other facades, including those oriented towards parking areas, private access ways, or interior courtyards, however, such entrances shall not replace or diminish the prominence or function of the required primary entrance.
iii. Buildings that do not front a public street shall be oriented towards their primary entrance, the most prominent pedestrian access route. Such entrances shall be directly connected to a defined pedestrian circulation system.
iv. Buildings located on corner lots shall be designed to face street intersections by being angled and setback to soften the intersection of perpendicular building facades and ensure clear view and create public space. This angled portion shall be provided with the front entrance façade type as the principal entry. In conjunction with the building angle, corner lots shall provide a corner plaza that is no less than 20' wide (as measured along the angled portion of the building) and to be no less than 15' deep at the narrowest point. (See Figure 50-2)
f. Façade Articulation/Details. The following standards apply to all facades facing a public or private right-of-way, primary access way, and/or open space. (See Figure 50-3)
i. Blank Wall Limitations. Both of the following shall be met for each story:
1. No rectangular area greater than 30% of a story’s façade, as measured from floor to floor, may be windowless; and
2. No horizontal segment of a story’s façade greater than 15' in width may be windowless.
g. Transparency & Fenestration Requirements.
i. All windows and doors shall consist of clear, non-reflective, transparent glass that allows views into and out of the building. Mirrored, opaque, tinted, or spandrel glass shall not be counted towards transparency requirements.
ii. Ground floor and upper floor transparency shall be provided in accordance with the minimum percentages established for each building type listed in Table 50-1.
iii. Ground floor transparency area shall be measured between two feet and eight feet above adjacent grade. Windows and doors located within the transparency area of a building shall be separated by no more than 15' in width. (See Figure 50-3)
iv. Minimum of 85% of the required ground floor transparency shall consist of vertically oriented windows with a minimum height of six feet. (See Figure 50-4)
v. Required transparency shall be located along primary street frontages, plazas, open space,
vi. Window shall be vertically proportioned and organized to reinforce the vertical rhythm of façade bays. Horizontal or small-format windows shall not be used to satisfy minimum transparency requirements, except where consistent with the requirements listed herein. (See Figures 50-3 and 50-4)
vii. Glazing associated with service areas, storage, mechanical rooms, or other back-of-house functions shall be limited to a maximum of 20% of the total required ground floor transparency.
viii. Required transparency shall be located along primary street frontages, plazas, and pedestrian-oriented areas as identified by the Development Staff.
ix. Windows along storefronts shall be recessed a minimum of three inches from the faced plane to create a showed depth.
x. Windows shall be organized within and alighted to vertical bays. Windows shall be arranged in coherent groupings, and isolated or scattered window placement is prohibited. (See Figures 50-3 and 50-4)
xi. The measurement of windows and doors shall include the outermost edge of the window or door frame.
h. Architectural Divisions.
i. Vertical Divisions. Facades shall be divided into vertical bays. The width of the bay shall be based on the building type. (See Table 50-1 and Figure 50-3)
ii. There shall be a minimum two feet shift from the plane of the primary wall every 45'. This depth shall be achieved through projections, recesses, columns, structural elements, or similar architecture.
iii. A horizontal expression line shall be provided at or near the top of the ground floor/store front area. This element shall occur within three feet of the ground floor ceiling line and shall include a minimum horizontal projection or recess with a depth of at least 18". Alternatively, the horizontal expression line may be provided through the use of a horizontal band that is a different material from the surrounding material(s) and has a minimum height of no less than 18". (See Figure 50-3)
Table 50-1
Building Type
Minimum Required Transparency
Vertical Divisions
(Bay Size)
Ground Floor
Upper Floors
Commercial
55%
35%
20'
Mixed-Use Commercial
55%
35%
25'
Mixed-Use Residential
40%
30%
25'
Office
30%
30%
30'

i. Location of Uses within Buildings. Uses within buildings shall comply with the minimum required occupied space per use as determined by building type and as shown in Figure 50-5.

j. Accessory Structures. Accessory structures are only permitted within the single-family subdistrict and shall be regulated per the R-1-6 (Single Family) Zone and Section 19.06.020.
k. Roof Types. All commercial, mixed-use, and office building types in the TC-1 zone shall have at least one permitted roof type, but may include multiple roof types outlined in this section. (See Appendix 50-A)
i. Pitched Roof.
1. Hipped, gabled, Asymmetrical gable, split shed, flat roof with parapet, tower, monitor (clerestory), intersecting shed roof, low-slope gable with extended eaves.
2. Parallel Ridge Line. When the ridge line runs parallel to the front lot line, a gabled end or perpendicular ridge line shall occur at least every 100' of roof.
3. Roof Height. Roofs without occupied space shall have a maximum height on street-facing facades equal to the maximum floor height for the permitted building type.
4. Occupied Space. Occupied space may be incorporated behind this roof type.
ii. Parapet Roof.
1. Height shall be measured from the top of the upper story to the top of the parapet.
a. Minimum height is two feet with a maximum height of six feet.
b. The parapet shall be high enough to screen the roof and any equipment from view.
c. Horizontal Expression Lines. On all sides of the building, expression lines shall define the parapet from the upper stories of the building and define the top of the parapet.
d. Perimeter. Parapets shall be used for the entire perimeter of the building, even when multiple roof types are used.
e. Occupied Spaces. Occupied space shall not be incorporated behind this roof type.
iii. Flat Roof.
1. Configuration. Roofs with no visible slope are acceptable. Eaves are required for entire perimeter of the building.
2. Eave Depth. Eave depth shall be measured from the building façade to the outside edge of the eave. Eaves shall have a depth of at least 14".
3. Eave Thickness. Eave thickness shall be measured at the outside edge of the eave, from the bottom of the eave to the top of the eave. Eaves shall be a minimum of eight inches thick.
4. Interrupting Vertical Walls. Vertical walls may interrupt the eave and extend above the top of the eave.
5. No more than one-half of the front façade can consist of an interrupting vertical wall.
6. Vertical walls shall extend no more than four feet above the top of the eave.
7. Occupied Space. Occupied space shall not be incorporated behind this roof type.
iv. Tower. For purposes of this section, chimneys are not considered towers.
1. Quantity. A limit of one tower is permitted per allowed building type.
2. Tower Height. Maximum height, measured from the top of the parapet or eave to the top of the tower, is the equivalent of the height of one upper floor of the building to which the tower is applied.
3. Tower Width. Maximum width along all facades is one-third the width of the front façade or 30', whichever is less.
4. Horizontal Expression Lines. An expression line shall define the tower from the upper stories for all commercial and mixed-used building types.
5. Occupied Space. Towers may be occupied by the same uses allowed in upper stories of the building type to which it is applied.
6. Application. May be combined with all other roof types.
7. Tower Cap. The tower may be caped by a parapet, pitched, low pitched, or flat roof type. A spire may also cap the tower.
v. Roof types that are not permitted. Gambrel, butterfly, or mansard roofs are not permitted.
l. Building Variety.
i. Building design shall vary between vertical façade divisions, as required per building type, and from adjacent buildings by the type of dominant material and/or color, scale or orientation of that material. This shall be accomplished in two of the following three ways:
1. The proportion of recesses and projections;
2. The location of the entrances and window placement, unless mixed-uses are utilized;
3. Roof type, plan, or material, unless otherwise stated in the building type requirements.
ii. Façade color palette shall be based on natural materials such as wood, stone, and metal and shall consist of muted, low intensity tones. Painted colors that mimic or replace natural material expressions with bright or highly saturated colors are prohibited.
iii. No more than two identical facades shall be located adjacent to each other.
iv. A façade design shall not repeat more than three times within a block face.
v. Entrances shall vary in location, project, and/or design treatment within a building.
m. Building Materials. Each building shall include the use of the following materials as provided herein.
i. Primary Building Materials. Primary materials shall be used for a minimum of 75% of each façade for buildings located in the Commercial and Mixed-Use sub-districts and a minimum of 60% of each façade for buildings located in the Town, Neighborhood, and Detached Residential sub-districts.
1. A combination of at least two primary materials shall be used to reach a minimum of 75% coverage of all facades of each building, except as specially modified for service areas. Openings for windows and doors containing transparent glass shall not be counted towards the amount required for primary or secondary materials.
2. Permitted Primary Materials.
a. Brick
b. Stone
c. Engineered Wood Siding (lapped, board and batten, or shingled)
d. Fiber Cement Board (lapped, board and batten, or shingled)
e. Mass timber, exposed structural timber
ii. Secondary materials shall not exceed 25% of any façade and shall be used for accents, trim, and/or architectural elements.
1. Permitted Secondary Materials.
a. Stone
b. Brick
c. Mass timber, exposed structural timber
d. Metal for beams, lintels, trim, and ornamentation; exterior architectural metal panels and cladding; and metal composite material panels and cladding.
e. Cast stone
f. Fiber Cement Board Panels and Phenolic Resin Panels
g. Fiber reinforced materials for trim, cornice elements including: glass fiber reinforced concrete (GFRC)
h. Textured or patterned concrete.
iii. Service areas shall be located to the side or rear of buildings and shall not be oriented towards the primary street, plaza, and/or pedestrian pathways.
1. Service area facades may have a reduced minimum percentage of primary materials to 40%, but shall only apply to the floors the service areas are located.
iv. If a material is used as a primary material, that same material cannot also be counted as a secondary material.
1. Natural Materials. Brick, stone, and/or timbers shall be applied individually or combined to a minimum of 30% of all front and side facades.
2. When brick and/or stone is used it shall be extended beyond any exterior wall corner by a minimum depth of 18" onto the adjoining (perpendicular) wall façade.
v. Secondary Building Materials. Secondary materials are used to highlight details and/or provide accents and architectural variety. Secondary materials may be used for a maximum of 25% of each façade for buildings in the Commercial and Mixed-Use sub-districts and a maximum of 40% of each façade for buildings in the Townhome Residential, Neighborhood Residential, and Detached Residential sub-districts.
vi. The land use authority may approve additional materials that demonstrate equal or superior quality, durability, and compatibility with the design standards.
vii. Prohibited Building Materials. Vinyl or aluminum siding, unfinished poured concrete, rusted metal, composite siding, corrugated metal, or CMU block.
n. Windows, Awnings, Shutters and Doors.
i. Windows. Percent of transparency is required per building type and as outlined in Table 50-1. All upper story windows shall be detailed with trim or molding at least four inches in width. Additionally, all upper story windows shall incorporate at least one of the following accent details.
1. Mullions and/or Transoms.
2. Shutters or canopies proportional to window size.
3. Recessed inset of at least two inches from the building façade.
4. Lintel and/or sill detail.
ii. Awnings/Canopies. Shall be canvas or metal. Plastic and vinyl awnings/canopies are prohibited. Types and colors for each building face shall be coordinated. Shall have a minimum clearance of ten feet in height and shall not project more than four feet into a right-of-way. (See Figure 50-6)
iii. Shutters. If installed, shutters whether functional or not, shall be sized for the windows. If closed, the shutters shall completely cover the window. Shutters shall not be made of plastic, vinyl, or other composite material. Wood and metal are examples of approved materials for shutters.
iv. Appropriate Grade of materials. Commercial quality doors, windows, and hardware shall be used on Commercial and Mixed-Use building types.

o. Mixed-Use and Commercial Lighting. External lighting shall be shielded and designed to cast downward onto a building or pedestrian walking surface. Lighting, including security lighting that casts outward is prohibited. Lighting strips (i.e. LED strips or other similar lighting) along building facades, tenant spaces, windows, and/or doors is prohibited.
p. Trash storage areas, mechanical equipment, transformers, air conditioning units, meters, and similar devices are not permitted to be visible from the street, or to be located on patios/balconies associated with a residential unit. Where site constraints would otherwise force these uses into visible locations, they shall be screened by decorative walls, earthen berms, landscaping, or architectural treatments capable of screening views from streets and sidewalks. If in rooftop locations, mechanical equipment shall be screened by roof components, parapets, cornices, or other architectural features.
q. Balconies and Patios. The following standards apply for balconies and ground level patios on the mixed-use residential building type.
i. Each residential unit shall have a balcony or patio with a minimum depth of five feet and minimum of 50 square feet.
ii. Trash storage areas, mechanical equipment, transformers, air conditioning units, meters, and similar devices are not permitted to be located on patios/balconies associated with a residential unit.
iii. Balconies are required for at least 50% of all residential units.
iv. Ground Level Patio Screening. Ground level patios shall be screened with a railing, fencing, and landscaping. Screening may extend to a height of four feet.
r. Building Mounted Utilities or Mechanical Equipment. All building mounted utilities or mechanical equipment shall be screened and is not permitted to be located along a primary building frontages.
2. Residential Amenities and Open Space.
a. Mixed-Use Residential Developments. To encourage livability for residents, each Mixed-Use Residential development must provide a mix of amenities as provided in Table 50-2.
i. Quantity of Residential Building Amenities. Each Mixed-Use Residential Building shall provide a minimum of six building amenities as outlined in Table 50-2
Table 50-2 Residential Building Amenities
Rooftop/Stepback Terrace of no less than 15' in depth
Green/landscaped roof (may count toward site amenity or residential outdoor space. May also be used to meet landscape requirements)
Lobby of at least 500 square feet
Interior social area, such as a common kitchen/dining area, media room, or event room
Indoor fitness room
Outdoor Dining Patio
Secure bike storage and repair station
Sport Court (indoor or outdoor)
Enclosed storage units (indoor use)
Pool (indoor, outdoor, or rooftop)
Hot Tub/Spa (indoor, outdoor, or rooftop)
Community Garden (may count toward site landscape requirements)
First-floor café/eatery (open to public or private to tenants)
Playground structure with benches (minimum of two)
Dog Park with at least four usable play elements and landscaped with sod
Comparable amenities may be proposed for review and approval
b. Townhouse, Mansion Style, and Twin Home Development Open Space. A minimum of 25% of the total area being developed shall be provided as usable open space. Open space shall comply with the following standards.
i. Areas used for storm water detention or retention shall comply with the following criteria:
1. The depth of the storm water basin shall be less than five feet vertical as measured from the top of the basin to the base.
2. The slope of the storm water basin shall not exceed a 5:1 (20%) slope ration. The slope access shall be at least ten feet wide for a minimum of two of the sides of the basin.
3. The width of the storm water basin shall be no less than 20' wide and 50' deep.
3. Attached Dwelling Units
a. Each unit shall have an expressed and unique identity between side-by-side residential units. Mirrored, repeated, or substantially identical units designs shall not be placed directly next to one another. Twin homes are exempt from this requirement.
b. End Unit Architecture Details: The end-unit side elevations shall incorporate at least one window associated with ground level living areas, and two windows associated with the upper stories. A minimum of one window shall incorporate a projecting feature, such as a bay window, cantilever, or pop-out element, extending at least one foot.
c. A gable, dormer or bay window is required for the front façade top story of each townhome, live/work, or twin home unit.
d. The identical application (same size, shape and pattern) of a gable, shed dormer or bay window shall not be repeated from one unit to an adjacent unit.
e. The minimum gable width shall be eight feet; the minimum dormer and bay window width shall be five feet.
f. The requirement for a gable, dormer or bay window variation for each unit may be substituted by a vertical offset in the roof ridge line between attached units.

i. Flat or low-sloping, single-pitched roofs shall be used as the dominate roof type.
ii. Wide eave overhangs with a minimum of 24" shall be utilized.
iii. When used, chimneys shall penetrate the main roof with the use of stone material.
iv. For residential buildings, roofs shall overhang to cover patios and decks.


a. Massing.
i. Overall massing should be simple and emphasize vertical elements with front-facing gable roofs and side wings recommended.
ii. Projecting bays and low-sloping shed roofs should be considered.
b. Roofs.
i. Gable roofs shall be oriented towards the street.
ii. Main roof pitches shall be: 6:12 to 12:12
iii. Secondary hip or shed roof pitches shall be: 3:12 to 6:12.
iv. Roof overhangs shall be between six to 12".
v. Square or more detailed moldings shall be provided along rakes.
vi. The use of shed or gable-end dormers should be utilized.
vii. The main gable should be intersected by other roofs.
c. Windows and Doors.
i. Windows and doors shall be vertically proportionate to single and double-hung windows.
ii. Exterior trim and cap moldings of four to six inches shall be incorporated for windows and doors. Stucco is not permitted for trim.
iii. Windows shall be vertically oriented.
iv. Square and angled bay window treatments should be considered.
v. Lites located in an entry door are common and should be considered to express ornamentation.
d. Porch/Entry.
i. Porches shall address the street and have a minimum width of seven feet and a minimum depth of seven feet. A three foot walkway approaching the unit and centered on the front door to the unit cannot be counted towards the minimum porch dimensions.
ii. Porches roofs shall be forward facing and incorporate a shed or hip style.
iii. Square columns for porches shall have a minimum dimension of six inches by six inches or if rounded shall be a minimum of six inches wide.
iv. Support columns shall have a base, shaft, and capital.
v. Exposed wood and metal elements should be considered.
vi. Railings should be steel and include square balusters or be turned.
e. Details and Materials.
i. All residential buildings shall include a decorative garage door.
ii. Lap siding or board and batten siding shall be provided on all four sides of the building.
iii. Vinyl siding is not permitted.
iv. Exposed concrete shall be clad with stone or brick.
v. Board and batten wainscoting (in courser spacing) shall be incorporated at a minimum along the main or front façade. Coverage of the entire façade is not required.
vi. Detailing should be simplified with restrained ornamentation.



The architectural themes for this town center are inspired by the historic agricultural tradition and the mountain valley geography. The standards outlined in this section are specific to the Gordon Avenue and Highway 89 Town Center and shall be followed for development therein for commercial, office, and mixed-use development.
The primary architectural style for the town center is the Mountain Modern style. This style shall be the focus of all commercial, office, and mixed-use buildings.
The architectural styles for attached and detached residential are Mountain Modern, Craftsman, Farmhouse, and Prairie. With each building type, a builder shall select a style and comply with the design guidelines and standards outlined in these subsections for each style.








Table 80-6 Estimated Tree Canopy and Height at Maturity
Tree Size
Estimated Height at Maturity
Estimated Mature Canopy Spread
Small
15' - 25'
12' - 18'
Medum
25' - 40'
20' - 30'
Large
40' +
40' - 60'

Table 90-1 Streetlight Standards
Standard
Street Type
Spacing
Tear Drop Pole & Fixture - SL-01
Town Center Arterial Streets
200'± (Stagger of ≈ 100')
Single Light Fluted Pole & Fixture – SL-04
Town Center Collector Streets
200’± (Stagger of ≈ 100’)
Double Light Fluted Pole – SL-03*
Town Center Collector Streets
200’± (Stagger of ≈ 100’)
* Only allowed in commercial or mixed-use sub-districts per Layton City Council
Table 90-2 Permitted Town Center Street Trees
Common Name
Scientific Name
Tree Size
Chanticleer Flowering Pear
Pyrus calleryana ‘Chanticleer’
Medium
Ginkgo
Ginkgo biloba – Male
Medium
Japanese Zelkova 'Musashino', or ' Green Vase'
Zelkova serrata ‘Musashino’
Zelkova serrata ‘Green Vase
Medium
Large
Street trees shall be provided in groupings.
Groupings shall alternate to provide street tree variety and a more natural variation between groupings.
Table 90-3 Town Center Street Tree Locations
Tree Type
Permitted Street Type
Tree Spacing
Small Trees
Town Center Local Streets and Private Streets
20' - 40' on center
Medium Trees
Town Center Collector and Arterial Streets
20' - 40' on center
Large Trees
Town Center Collector and Arterial Streets
30' - 60' on center
Street trees shall be placed no closer than 20' from any streetlight or traffic signal.




Right-of-Way (ROW) Width
97' - 113'
Vehicular Realm
Parking Lanes
Optional Parallel, as ROW permits
Active Transportation Facilities
Per Layton City Active Transporation Plan
Pedestrian Realm
Furnishing Zone
Minimum 8' wide - Hardscape
Clear Sidewalk
Minimum 8' wide

Right-of-Way Width
73' - 79'
Vehicular Realm
Parking Lanes
Optional Parallel, as ROW permits
Active Transportation Facilities
Per Layton City Active Transportation Plan
Pedestrian Realm
Furnishing Zone
Minimum 8' wide - Hardscape
Clear Sidewalk
Minimum 8' wide

Table 90-7 Town Center Local Street
Right-of-Way (ROW) Width
61' - 65'
Vehicular Realm
Parking Lanes
Optional Parallel, as ROW permits
Active Transportation Facilities
Shared Travel Lane and Per Layton
City Active Transportation Plan
Pedestrian Realm
Furnishing Zone
Minimum 6' wide - Hardscape
Clear Sidewalk
Minimum 8' wide

Right-of-Way Width
61' - 65'
Vehicular Realm
Parking Lanes
Optional Parallel, as ROW permits
Active Transportation Facilities
Shared Travel Lane and Per Layton
City Active Transportation Plan
Pedestrian Realm
Park Strip
Minimum 8' wide - Waterwise Softscape
Clear Sidewalk
Minimum 6' wide

Table 90-9 Primary Access Way (Private)
Vehicular Realm
Parking Lanes
Parallel stalls may be provided. Shall
comply with minimum dimension
standards outlined in LMC 19.12.110
Active Transportation Facilities
May be shared with wayfinding signage
Pedestrian Realm
Landscape Buffer
Minimum 3' wide landscaped area
between sidewalk and parking areas
and/or the access way. The
landscaping shall, at a minimum,
consist of water-efficient grasses
and shrubs and provide 50%
ground coverage at maturity.
Clear Sidewalk
Minimum 6' wide


Signage within TC-1 Zone shall comply with the standards outlined in Title 20 "Sign Regulations".