28.040

SR-V2 DISTRICT.

(1)

Permitted and Conditional Uses.

See Table 28C-1 for a complete list of allowed uses within the residential districts.

(2)

Dimensional Requirements, Permitted and Conditional Uses.

Requirements represent minimums unless otherwise noted. Dimensions are in feet unless otherwise noted.

SR-V2 District: Permitted Uses
Single-family detachedTwo-family Two unitTwo-family - TwinSingle-family attached (8 units max.)Multi-family (3—24 units max.)
Lot Area (sq. ft.) 5,000 5,000 2,500/d.u. 1,500/d.u. 1,500/d.u.
Lot Width 50 50 25/d.u. 20/d.u. 60
Front Yard Setback 25 25 25 25 25
Side Yard Setback 5 Two-story: 5 5 Exterior end walls: 5 10
Reversed Corner Side Yard Setback 12 12 12 12 12
Rear Yard Lesser of 25% lot depth or 25
Alley accessed: 3
See (a) below
Lesser of 25% lot depth or 25
Alley accessed: 3
See (a) below
Lesser of 25% lot depth or 25
Alley accessed: 3
See (a) below
Lesser of 25% lot depth or 25
Alley accessed: 3
See (a) below
Lesser of 25% lot depth or
25
Maximum height 2 stories/35 2 stories/35 2 stories/35 3 stories/40 3 stories/40
Maximum lot coverage 60% 60% 60% 90% 60%

 

(ORD-17-00127, 12-18-17; Amd. by ORD-18-00049, 5-14-18; Am. by ORD-21-00044, 6-14-21; Am. by ORD-25-00011, 3-8-25; Am. by ORD-25-00066, 10-16-25)

(a)

Only a one-story, alley-accessed attached garage projection for garage purposes may have a minimum rear yard setback of three (3) feet. (Cr. by ORD-25-00066, 10-16-25)

SR-V2 District: Conditional and Nonresidential Uses
Single-family attached (>8 units)Multi-family (>24 units)Nonresidential
Lot Area (sq. ft.) 1,500/d.u. 1,500/d.u. 6,000
Lot Width 20/d.u. 60 50
Front Yard Setback 25 25 25
Side Yard Setback Exterior end walls: 6 10 6
Reversed Corner Side Yard Setback 12 12 25
Rear Yard Lesser of 25% lot depth or 25
Alley accessed: 3
See (a) below
Lesser of 25% lot depth or 25 Equal to building height but at least 25
Maximum height 3 stories/40 4 stories/52 35
Maximum lot coverage 90% 60% 60%
Maximum building coverage n/a n/a 50%

 

(Amd. by ORD-18-00049, 5-14-18; Am. by ORD-21-00044, 6-14-21; Am. by ORD-25-00011, 3-8-25; Am. by ORD-25-00066, 10-16-25)

(a)

Only a one-story, alley-accessed attached garage projection for garage purposes may have a minimum rear yard setback of three (3) feet. (Am. by ORD-25-00066, 10-16-25)