Zoning Districts
Purpose: This Chapter is enacted to promote and protect the health, safety and general welfare of the people of the County. It is the intention of the Board of Supervisors that the provisions of this Chapter will implement the purpose and intent of the Comprehensive Plan of the County by encouraging the most desirable use of the land for residential, recreational, agricultural, forestry, commercial, industrial, conservation, public service, floodplain, drainage, and other purposes; by encouraging the most appropriate use and occupancy of buildings; by protecting and improving the quality of the waters within and adjacent to the County; and by promoting good civic design and arrangement. The provisions of this Chapter provide reasonable standards with respect to the location, height, bulk, size of buildings, and other structures; yard areas, courts, off-street parking facilities and other open spaces; the use of buildings, structures; and land for trade, industry, business, residence, or other purposes.
Generally. The standards in the following overlays supersede the typical district standards identified in Article 2, Divisions 2, 3, and 4 and the development standards in Article 4 where applicable. Where the overlay does not have a standard or is silent, the County-wide standards shall apply.
Land Uses. The permitted by-right (P), permitted subject to restrictions (R), conditional (C), conditional use with additional guidance (C*), special exception (S), and prohibited uses are set out in the underlying zoning district (see Article 3, Uses).
The County is divided into the following zoning districts:
| Table 19.2-71 Zoning Districts | |||
|---|---|---|---|
| District | Symbol | Comprehensive Plan Category | Reference |
| Residential Districts | |||
| Agricultural | A | Rural Residential/Agricultural, Residential Agricultural | 19.2-8 |
| Rural Community | RC | Rural Residential/Agricultural, Residential Agricultural | 19.2-9 |
| Semi-Rural Neighborhood | SR | Residential Agricultural, Residential Neighborhood 1 | 19.2-10 |
| Suburban Community | SC | Phased Residential, Residential Neighborhood 2, and Residential Neighborhood 4 | 19.2-11 |
| Semi-Urban Neighborhood | SU | Residential Neighborhood 4, Residential Neighborhood 8 | 19.2-12 |
Transition Residential | TR | Residential Neighborhood 8, Residential Neighborhood 12 | 19.2-13 |
Urban Residential | UR | Neighborhood Mixed-Use, Community Mixed-Use, and Regional Mixed-Use | 19.2-14 |
Alternative Residential | AR | 19.2-15 | |
| Commercial and Mixed-Use Districts | |||
Neighborhood Business | NB | Light Business | 19.2-16 |
| Corridor Commercial | CC | Arterial Business | 19.2-17 |
Mixed-Use Center | MU | Neighborhood Mixed-Use, Community Mixed-Use, Regional Mixed-Use | 19.2-18 |
| Employment Districts | |||
| Employment Center | EC | Office/Light Production and Assembly (OLPA) | 19.2-19 |
Employment General | EG | Manufacturing and Processing | 19.2-20 |
Warehouse & Distribution | WD | Office/Light Production and Assembly (OLPA), Manufacturing and Processing | 19.2-21 |
| Overlay Districts | |||
| Village Overlay | VO | Specific Area Plans | 19.2-22 |
| Urban Corridor Overlay | UCO | Specific Area Plans | 19.2-23 |
| Roseland Zoning Overlay | RZO | Residential Neighborhood 2, Light Business, Residential Neighborhood 12, Regional Mixed Use, Office/Light Production and Assembly (OLPA) | 19.2-24 |
| Airport Overlays | AO | Chesterfield County Airport Operational and Runway Approach Areas | 19.2-25 |
| Chesapeake Bay Preservation Areas |
CBPA | 19.2-26 | |
| Floodplain Management Districts | F | 19.2-27 | |
| Table 19.2-71 Zoning Districts | |||
|---|---|---|---|
| District | Symbol | Comprehensive Plan Category | Reference |
| Residential Districts | |||
| Agricultural | A | Rural Residential/Agricultural, Residential Agricultural | 19.2-8 |
| Rural Community | RC | Rural Residential/Agricultural, Residential Agricultural | 19.2-9 |
| Semi-Rural Neighborhood | SR | Residential Agricultural, Residential Neighborhood 1 | 19.2-10 |
| Suburban Community | SC | Phased Residential, Residential Neighborhood 2, and Residential Neighborhood 4 | 19.2-11 |
| Semi-Urban Neighborhood | SU | Residential Neighborhood 4, Residential Neighborhood 8 | 19.2-12 |
Transition Residential | TR | Residential Neighborhood 8, Residential Neighborhood 12 | 19.2-13 |
Urban Residential | UR | Neighborhood Mixed-Use, Community Mixed-Use, and Regional Mixed-Use | 19.2-14 |
Alternative Residential | AR | 19.2-15 | |
| Commercial and Mixed-Use Districts | |||
Neighborhood Business | NB | Light Business | 19.2-16 |
| Corridor Commercial | CC | Arterial Business | 19.2-17 |
Mixed-Use Center | MU | Neighborhood Mixed-Use, Community Mixed-Use, Regional Mixed-Use | 19.2-18 |
| Employment Districts | |||
| Employment Center | EC | Office/Light Production and Assembly (OLPA) | 19.2-19 |
Employment General | EG | Manufacturing and Processing | 19.2-20 |
Warehouse & Distribution | WD | Office/Light Production and Assembly (OLPA), Manufacturing and Processing | 19.2-21 |
| Overlay Districts | |||
| Village Overlay | VO | Specific Area Plans | 19.2-22 |
| Urban Corridor Overlay | UCO | Specific Area Plans | 19.2-23 |
| Roseland Zoning Overlay | RZO | Residential Neighborhood 2, Light Business, Residential Neighborhood 12, Regional Mixed Use, Office/Light Production and Assembly (OLPA) | 19.2-24 |
| Airport Overlays | AO | Chesterfield County Airport Operational and Runway Approach Areas | 19.2-25 |
| Chesapeake Bay Preservation Areas |
CBPA | 19.2-26 | |
| Floodplain Management Districts | F | 19.2-27 | |
| Table 19.2-71 Zoning Districts | |||
|---|---|---|---|
| District | Symbol | Comprehensive Plan Category | Reference |
| Residential Districts | |||
| Agricultural | A | Rural Residential/Agricultural, Residential Agricultural | 19.2-8 |
| Rural Community | RC | Rural Residential/Agricultural, Residential Agricultural | 19.2-9 |
| Semi-Rural Neighborhood | SR | Residential Agricultural, Residential Neighborhood 1 | 19.2-10 |
| Suburban Community | SC | Phased Residential, Residential Neighborhood 2, and Residential Neighborhood 4 | 19.2-11 |
| Semi-Urban Neighborhood | SU | Residential Neighborhood 4, Residential Neighborhood 8 | 19.2-12 |
Transition Residential | TR | Residential Neighborhood 8, Residential Neighborhood 12 | 19.2-13 |
Urban Residential | UR | Neighborhood Mixed-Use, Community Mixed-Use, and Regional Mixed-Use | 19.2-14 |
Alternative Residential | AR | 19.2-15 | |
| Commercial and Mixed-Use Districts | |||
Neighborhood Business | NB | Light Business | 19.2-16 |
| Corridor Commercial | CC | Arterial Business | 19.2-17 |
Mixed-Use Center | MU | Neighborhood Mixed-Use, Community Mixed-Use, Regional Mixed-Use | 19.2-18 |
| Employment Districts | |||
| Employment Center | EC | Office/Light Production and Assembly (OLPA) | 19.2-19 |
Employment General | EG | Manufacturing and Processing | 19.2-20 |
Warehouse & Distribution | WD | Office/Light Production and Assembly (OLPA), Manufacturing and Processing | 19.2-21 |
| Overlay Districts | |||
| Village Overlay | VO | Specific Area Plans | 19.2-22 |
| Urban Corridor Overlay | UCO | Specific Area Plans | 19.2-23 |
| Roseland Zoning Overlay | RZO | Residential Neighborhood 2, Light Business, Residential Neighborhood 12, Regional Mixed Use, Office/Light Production and Assembly (OLPA) | 19.2-24 |
| Airport Overlays | AO | Chesterfield County Airport Operational and Runway Approach Areas | 19.2-25 |
| Chesapeake Bay Preservation Areas |
CBPA | 19.2-26 | |
| Floodplain Management Districts | F | 19.2-27 | |
| Table 19.2-71 Zoning Districts | |||
|---|---|---|---|
| District | Symbol | Comprehensive Plan Category | Reference |
| Residential Districts | |||
| Agricultural | A | Rural Residential/Agricultural, Residential Agricultural | 19.2-8 |
| Rural Community | RC | Rural Residential/Agricultural, Residential Agricultural | 19.2-9 |
| Semi-Rural Neighborhood | SR | Residential Agricultural, Residential Neighborhood 1 | 19.2-10 |
| Suburban Community | SC | Phased Residential, Residential Neighborhood 2, and Residential Neighborhood 4 | 19.2-11 |
| Semi-Urban Neighborhood | SU | Residential Neighborhood 4, Residential Neighborhood 8 | 19.2-12 |
Transition Residential | TR | Residential Neighborhood 8, Residential Neighborhood 12 | 19.2-13 |
Urban Residential | UR | Neighborhood Mixed-Use, Community Mixed-Use, and Regional Mixed-Use | 19.2-14 |
Alternative Residential | AR | 19.2-15 | |
| Commercial and Mixed-Use Districts | |||
Neighborhood Business | NB | Light Business | 19.2-16 |
| Corridor Commercial | CC | Arterial Business | 19.2-17 |
Mixed-Use Center | MU | Neighborhood Mixed-Use, Community Mixed-Use, Regional Mixed-Use | 19.2-18 |
| Employment Districts | |||
| Employment Center | EC | Office/Light Production and Assembly (OLPA) | 19.2-19 |
Employment General | EG | Manufacturing and Processing | 19.2-20 |
Warehouse & Distribution | WD | Office/Light Production and Assembly (OLPA), Manufacturing and Processing | 19.2-21 |
| Overlay Districts | |||
| Village Overlay | VO | Specific Area Plans | 19.2-22 |
| Urban Corridor Overlay | UCO | Specific Area Plans | 19.2-23 |
| Roseland Zoning Overlay | RZO | Residential Neighborhood 2, Light Business, Residential Neighborhood 12, Regional Mixed Use, Office/Light Production and Assembly (OLPA) | 19.2-24 |
| Airport Overlays | AO | Chesterfield County Airport Operational and Runway Approach Areas | 19.2-25 |
| Chesapeake Bay Preservation Areas |
CBPA | 19.2-26 | |
| Floodplain Management Districts | F | 19.2-27 | |
Purpose. The Agricultural (A) District provides land areas for large lot single-family dwellings as well as forest and farmland including agricultural and silvicultural operations and ancillary uses that contribute to and complement the natural environment and rural character. The role of this district is to preserve natural areas, water resources, wildlife habitat, and open spaces while protecting the rural economy of the County and preventing the encroachment of premature and incompatible land uses.
| Table 19.2-8.1, Agricultural (A) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||||||
| Key | Development | Base | Option 1 | |||||
| Neighborhood Type | Lots recorded: | Non-Residential | ||||||
| After 02.27.01 | 05.26.88 thru 02.27.01 | Before 05.26.88 | ||||||
| Lot Standards | ||||||||
| A | Lot Area (min) [1] [2] | 5.0 ac | 1.0 ac | 15,000 sf. | 1.0 ac | |||
| B | Lot Width (min) [3] | 150' | 150' | 100' | 150' | |||
| C | Road Frontage (min) [4] [5] | 250' | 50' | 50' | 50' | |||
| D | Building Coverage (max) | 20% | 20% | 30% | 20% | |||
| Building Standards | ||||||||
| Principal Building Placement [6] [7] | ||||||||
| E | Front Setback (min) | 150' | 150' [8] | 100' [9] | [13] | |||
| F | Side Setback (min) | 40' | 40' | 15' /10' [10] | [13] | |||
| G | Corner Side Setback (min) - Through Lot back-to-back with another corner lot or backing to open space or common areas - Other |
40'
75' |
40'
75' |
20'
35' [11] |
[13]
[13] | |||
| H | Rear Setback (min) - Non-Through Lot - Through Lot |
50' 150' |
50' 150' [7] |
25' 100' [8] | [13] [13] | |||
| Accessory Building Placement | ||||||||
| I | Front Setback (min) | Lesser of 1/2 the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | 40' | 40' | 15' | [13] | |||
| K | Corner Side Setback (min) - Buildings Less Than 15' in Height - Buildings 15' or Greater in Height | 150'
150' | 150'
150' | [12]
[12] | [13] | |||
| L | Rear Setback (min) - Standard Lot - Through Lot |
25' 30' |
25' 30' |
12.5' 30' | [13] | |||
| Accessory Building Placement for Structures under 15' in height | ||||||||
| Front Setback (min) | Lesser of 1/2 the average depth of the lot or 80' | |||||||
| Side Setback (min) | 20' | 20' | 7.5' | [13] | ||||
| Corner Side Setback (min) | 150' | 150' | [12] | [13] | ||||
Rear Setback (min) - Standard Lot - Through Lot |
10' 30' |
10' 30' |
10' 30' | [13] | ||||
| Building Height | ||||||||
| M | Principal Building height (max) | 45' | 45' | 45' | 45' | |||
Farm Structure Height, Village Overlay (max) Farm Structure Height, Other Areas (max) | 45' 50' | 45' 50' | 45' 50' | 45' 50' | ||||
| Parking | ||||||||
| N | Parking Lot Setback | -- | -- | -- | 50' | |||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Not Required, unless required by County Code Sec. 18-60. | Not Required, unless required by County Code Sec. 18-60. | Not Required, unless required by County Code 18-60. | Not Required, unless required by County Code 18-60. | |||
Notes:
| ||||||||
| Table 19.2-8.1, Agricultural (A) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||||||
| Key | Development | Base | Option 1 | |||||
| Neighborhood Type | Lots recorded: | Non-Residential | ||||||
| After 02.27.01 | 05.26.88 thru 02.27.01 | Before 05.26.88 | ||||||
| Lot Standards | ||||||||
| A | Lot Area (min) [1] [2] | 5.0 ac | 1.0 ac | 15,000 sf. | 1.0 ac | |||
| B | Lot Width (min) [3] | 150' | 150' | 100' | 150' | |||
| C | Road Frontage (min) [4] [5] | 250' | 50' | 50' | 50' | |||
| D | Building Coverage (max) | 20% | 20% | 30% | 20% | |||
| Building Standards | ||||||||
| Principal Building Placement [6] [7] | ||||||||
| E | Front Setback (min) | 150' | 150' [8] | 100' [9] | [13] | |||
| F | Side Setback (min) | 40' | 40' | 15' /10' [10] | [13] | |||
| G | Corner Side Setback (min) - Through Lot back-to-back with another corner lot or backing to open space or common areas - Other |
40'
75' |
40'
75' |
20'
35' [11] |
[13]
[13] | |||
| H | Rear Setback (min) - Non-Through Lot - Through Lot |
50' 150' |
50' 150' [7] |
25' 100' [8] | [13] [13] | |||
| Accessory Building Placement | ||||||||
| I | Front Setback (min) | Lesser of 1/2 the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | 40' | 40' | 15' | [13] | |||
| K | Corner Side Setback (min) - Buildings Less Than 15' in Height - Buildings 15' or Greater in Height | 150'
150' | 150'
150' | [12]
[12] | [13] | |||
| L | Rear Setback (min) - Standard Lot - Through Lot |
25' 30' |
25' 30' |
12.5' 30' | [13] | |||
| Accessory Building Placement for Structures under 15' in height | ||||||||
| Front Setback (min) | Lesser of 1/2 the average depth of the lot or 80' | |||||||
| Side Setback (min) | 20' | 20' | 7.5' | [13] | ||||
| Corner Side Setback (min) | 150' | 150' | [12] | [13] | ||||
Rear Setback (min) - Standard Lot - Through Lot |
10' 30' |
10' 30' |
10' 30' | [13] | ||||
| Building Height | ||||||||
| M | Principal Building height (max) | 45' | 45' | 45' | 45' | |||
Farm Structure Height, Village Overlay (max) Farm Structure Height, Other Areas (max) | 45' 50' | 45' 50' | 45' 50' | 45' 50' | ||||
| Parking | ||||||||
| N | Parking Lot Setback | -- | -- | -- | 50' | |||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Not Required, unless required by County Code Sec. 18-60. | Not Required, unless required by County Code Sec. 18-60. | Not Required, unless required by County Code 18-60. | Not Required, unless required by County Code 18-60. | |||
Notes:
| ||||||||
| Table 19.2-8.1, Agricultural (A) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||||||
| Key | Development | Base | Option 1 | |||||
| Neighborhood Type | Lots recorded: | Non-Residential | ||||||
| After 02.27.01 | 05.26.88 thru 02.27.01 | Before 05.26.88 | ||||||
| Lot Standards | ||||||||
| A | Lot Area (min) [1] [2] | 5.0 ac | 1.0 ac | 15,000 sf. | 1.0 ac | |||
| B | Lot Width (min) [3] | 150' | 150' | 100' | 150' | |||
| C | Road Frontage (min) [4] [5] | 250' | 50' | 50' | 50' | |||
| D | Building Coverage (max) | 20% | 20% | 30% | 20% | |||
| Building Standards | ||||||||
| Principal Building Placement [6] [7] | ||||||||
| E | Front Setback (min) | 150' | 150' [8] | 100' [9] | [13] | |||
| F | Side Setback (min) | 40' | 40' | 15' /10' [10] | [13] | |||
| G | Corner Side Setback (min) - Through Lot back-to-back with another corner lot or backing to open space or common areas - Other |
40'
75' |
40'
75' |
20'
35' [11] |
[13]
[13] | |||
| H | Rear Setback (min) - Non-Through Lot - Through Lot |
50' 150' |
50' 150' [7] |
25' 100' [8] | [13] [13] | |||
| Accessory Building Placement | ||||||||
| I | Front Setback (min) | Lesser of 1/2 the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | 40' | 40' | 15' | [13] | |||
| K | Corner Side Setback (min) - Buildings Less Than 15' in Height - Buildings 15' or Greater in Height | 150'
150' | 150'
150' | [12]
[12] | [13] | |||
| L | Rear Setback (min) - Standard Lot - Through Lot |
25' 30' |
25' 30' |
12.5' 30' | [13] | |||
| Accessory Building Placement for Structures under 15' in height | ||||||||
| Front Setback (min) | Lesser of 1/2 the average depth of the lot or 80' | |||||||
| Side Setback (min) | 20' | 20' | 7.5' | [13] | ||||
| Corner Side Setback (min) | 150' | 150' | [12] | [13] | ||||
Rear Setback (min) - Standard Lot - Through Lot |
10' 30' |
10' 30' |
10' 30' | [13] | ||||
| Building Height | ||||||||
| M | Principal Building height (max) | 45' | 45' | 45' | 45' | |||
Farm Structure Height, Village Overlay (max) Farm Structure Height, Other Areas (max) | 45' 50' | 45' 50' | 45' 50' | 45' 50' | ||||
| Parking | ||||||||
| N | Parking Lot Setback | -- | -- | -- | 50' | |||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Not Required, unless required by County Code Sec. 18-60. | Not Required, unless required by County Code Sec. 18-60. | Not Required, unless required by County Code 18-60. | Not Required, unless required by County Code 18-60. | |||
Notes:
| ||||||||
| Table 19.2-8.1, Agricultural (A) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||||||
| Key | Development | Base | Option 1 | |||||
| Neighborhood Type | Lots recorded: | Non-Residential | ||||||
| After 02.27.01 | 05.26.88 thru 02.27.01 | Before 05.26.88 | ||||||
| Lot Standards | ||||||||
| A | Lot Area (min) [1] [2] | 5.0 ac | 1.0 ac | 15,000 sf. | 1.0 ac | |||
| B | Lot Width (min) [3] | 150' | 150' | 100' | 150' | |||
| C | Road Frontage (min) [4] [5] | 250' | 50' | 50' | 50' | |||
| D | Building Coverage (max) | 20% | 20% | 30% | 20% | |||
| Building Standards | ||||||||
| Principal Building Placement [6] [7] | ||||||||
| E | Front Setback (min) | 150' | 150' [8] | 100' [9] | [13] | |||
| F | Side Setback (min) | 40' | 40' | 15' /10' [10] | [13] | |||
| G | Corner Side Setback (min) - Through Lot back-to-back with another corner lot or backing to open space or common areas - Other |
40'
75' |
40'
75' |
20'
35' [11] |
[13]
[13] | |||
| H | Rear Setback (min) - Non-Through Lot - Through Lot |
50' 150' |
50' 150' [7] |
25' 100' [8] | [13] [13] | |||
| Accessory Building Placement | ||||||||
| I | Front Setback (min) | Lesser of 1/2 the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | 40' | 40' | 15' | [13] | |||
| K | Corner Side Setback (min) - Buildings Less Than 15' in Height - Buildings 15' or Greater in Height | 150'
150' | 150'
150' | [12]
[12] | [13] | |||
| L | Rear Setback (min) - Standard Lot - Through Lot |
25' 30' |
25' 30' |
12.5' 30' | [13] | |||
| Accessory Building Placement for Structures under 15' in height | ||||||||
| Front Setback (min) | Lesser of 1/2 the average depth of the lot or 80' | |||||||
| Side Setback (min) | 20' | 20' | 7.5' | [13] | ||||
| Corner Side Setback (min) | 150' | 150' | [12] | [13] | ||||
Rear Setback (min) - Standard Lot - Through Lot |
10' 30' |
10' 30' |
10' 30' | [13] | ||||
| Building Height | ||||||||
| M | Principal Building height (max) | 45' | 45' | 45' | 45' | |||
Farm Structure Height, Village Overlay (max) Farm Structure Height, Other Areas (max) | 45' 50' | 45' 50' | 45' 50' | 45' 50' | ||||
| Parking | ||||||||
| N | Parking Lot Setback | -- | -- | -- | 50' | |||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Not Required, unless required by County Code Sec. 18-60. | Not Required, unless required by County Code Sec. 18-60. | Not Required, unless required by County Code 18-60. | Not Required, unless required by County Code 18-60. | |||
Notes:
| ||||||||
Table 19.2-8.3, Principal Building Placement (where zoning approval has been granted to allow use for dwelling purposes or a manufactured home without public road frontage) [1] [2] | |
|---|---|
| Development | Standard |
| Front Setback (min) [3] | 40' |
| Side Setback (min) | 15' |
| Rear Setback (min) | 25' |
Notes:
| |
Table 19.2-8.3, Principal Building Placement (where zoning approval has been granted to allow use for dwelling purposes or a manufactured home without public road frontage) [1] [2] | |
|---|---|
| Development | Standard |
| Front Setback (min) [3] | 40' |
| Side Setback (min) | 15' |
| Rear Setback (min) | 25' |
Notes:
| |
Table 19.2-8.3, Principal Building Placement (where zoning approval has been granted to allow use for dwelling purposes or a manufactured home without public road frontage) [1] [2] | |
|---|---|
| Development | Standard |
| Front Setback (min) [3] | 40' |
| Side Setback (min) | 15' |
| Rear Setback (min) | 25' |
Notes:
| |
Table 19.2-8.3, Principal Building Placement (where zoning approval has been granted to allow use for dwelling purposes or a manufactured home without public road frontage) [1] [2] | |
|---|---|
| Development | Standard |
| Front Setback (min) [3] | 40' |
| Side Setback (min) | 15' |
| Rear Setback (min) | 25' |
Notes:
| |
| Figure 19.2-8.1, A Illustrated Renderings |
|---|
| Base |
|
|
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-8.1, A Illustrated Renderings |
|---|
| Base |
|
|
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-8.1, A Illustrated Renderings |
|---|
| Base |
|
|
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-8.1, A Illustrated Renderings |
|---|
| Base |
|
|
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Provisions Related to the A District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Dimensional Standards | Sec. 19.2-37 |
| Landscaping and Screening | Sec. 19.2-41 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
(ZO-2025-002, Relative to Auto Sales, Required Utility Connections, and Site Plans, adopted 12/17/2025, effective 01/01/2026)
Purpose. The Rural Community (RC) District provides for residential development on minimum five acre lots. The role of the RC District is to provide a large lot subdivision development option served by new or existing public roads in the rural areas of the County with limited agricultural related uses.
| Table 19.2-9.1, Rural Community (RC) Lot and Building Standards | ||||
|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||
| Key | Development | Base | ||
| Neighborhood Type | Single-Family | |||
| -- | Amenity Space (min) | -- | ||
| Lot Standards | ||||
| A | Lot Area (min) | 5.0 ac | ||
| B | Lot Width (min) | 150' | ||
| C | Road Frontage (min) | 250' [1] | ||
| D | Building Coverage (max) | 20% | ||
| Building Standards | ||||
| Principal Building Placement [2] | ||||
| E | Front Setback (min) | 150' | ||
| F | Side Setback (min) | 40' | ||
| G | Corner Side Setback (min) - Through Lot, Lot Back-to-Back, or Lot Backing to Amenity Space - Other |
40' 75' | ||
| H | Rear Setback (min) - Non-Through Lot - Through Lot |
50' 150' | ||
| Accessory Building Placement | ||||
| I | Front Setback (min) | 100' | ||
| J | Side Setback (min) | 40' | ||
| K | Corner Side Setback (min) | 150' | ||
Rear Setback (min) - Standard Lot, 15' or Greater in Height - Through Lot, 15' or Greater in Height | 25' 30' | |||
| L | Accessory Building Placement for Structures Under 15' in Height | |||
| Front Setback (min) | 100' | |||
| Side Setback (min) | 20' | |||
| Corner Side Setback (min) | 150' | |||
Rear Setback - Standard Lot - Through Lot |
10' 30' | |||
| Principal & Accessory Building Height | ||||
| M | Height (max) | 45' | ||
| Utilities | ||||
Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Not required, unless required by County Code Sec. 18-60. | |||
Notes:
| ||||
| Table 19.2-9.1, Rural Community (RC) Lot and Building Standards | ||||
|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||
| Key | Development | Base | ||
| Neighborhood Type | Single-Family | |||
| -- | Amenity Space (min) | -- | ||
| Lot Standards | ||||
| A | Lot Area (min) | 5.0 ac | ||
| B | Lot Width (min) | 150' | ||
| C | Road Frontage (min) | 250' [1] | ||
| D | Building Coverage (max) | 20% | ||
| Building Standards | ||||
| Principal Building Placement [2] | ||||
| E | Front Setback (min) | 150' | ||
| F | Side Setback (min) | 40' | ||
| G | Corner Side Setback (min) - Through Lot, Lot Back-to-Back, or Lot Backing to Amenity Space - Other |
40' 75' | ||
| H | Rear Setback (min) - Non-Through Lot - Through Lot |
50' 150' | ||
| Accessory Building Placement | ||||
| I | Front Setback (min) | 100' | ||
| J | Side Setback (min) | 40' | ||
| K | Corner Side Setback (min) | 150' | ||
Rear Setback (min) - Standard Lot, 15' or Greater in Height - Through Lot, 15' or Greater in Height | 25' 30' | |||
| L | Accessory Building Placement for Structures Under 15' in Height | |||
| Front Setback (min) | 100' | |||
| Side Setback (min) | 20' | |||
| Corner Side Setback (min) | 150' | |||
Rear Setback - Standard Lot - Through Lot |
10' 30' | |||
| Principal & Accessory Building Height | ||||
| M | Height (max) | 45' | ||
| Utilities | ||||
Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Not required, unless required by County Code Sec. 18-60. | |||
Notes:
| ||||
| Table 19.2-9.1, Rural Community (RC) Lot and Building Standards | ||||
|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||
| Key | Development | Base | ||
| Neighborhood Type | Single-Family | |||
| -- | Amenity Space (min) | -- | ||
| Lot Standards | ||||
| A | Lot Area (min) | 5.0 ac | ||
| B | Lot Width (min) | 150' | ||
| C | Road Frontage (min) | 250' [1] | ||
| D | Building Coverage (max) | 20% | ||
| Building Standards | ||||
| Principal Building Placement [2] | ||||
| E | Front Setback (min) | 150' | ||
| F | Side Setback (min) | 40' | ||
| G | Corner Side Setback (min) - Through Lot, Lot Back-to-Back, or Lot Backing to Amenity Space - Other |
40' 75' | ||
| H | Rear Setback (min) - Non-Through Lot - Through Lot |
50' 150' | ||
| Accessory Building Placement | ||||
| I | Front Setback (min) | 100' | ||
| J | Side Setback (min) | 40' | ||
| K | Corner Side Setback (min) | 150' | ||
Rear Setback (min) - Standard Lot, 15' or Greater in Height - Through Lot, 15' or Greater in Height | 25' 30' | |||
| L | Accessory Building Placement for Structures Under 15' in Height | |||
| Front Setback (min) | 100' | |||
| Side Setback (min) | 20' | |||
| Corner Side Setback (min) | 150' | |||
Rear Setback - Standard Lot - Through Lot |
10' 30' | |||
| Principal & Accessory Building Height | ||||
| M | Height (max) | 45' | ||
| Utilities | ||||
Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Not required, unless required by County Code Sec. 18-60. | |||
Notes:
| ||||
| Table 19.2-9.1, Rural Community (RC) Lot and Building Standards | ||||
|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||
| Key | Development | Base | ||
| Neighborhood Type | Single-Family | |||
| -- | Amenity Space (min) | -- | ||
| Lot Standards | ||||
| A | Lot Area (min) | 5.0 ac | ||
| B | Lot Width (min) | 150' | ||
| C | Road Frontage (min) | 250' [1] | ||
| D | Building Coverage (max) | 20% | ||
| Building Standards | ||||
| Principal Building Placement [2] | ||||
| E | Front Setback (min) | 150' | ||
| F | Side Setback (min) | 40' | ||
| G | Corner Side Setback (min) - Through Lot, Lot Back-to-Back, or Lot Backing to Amenity Space - Other |
40' 75' | ||
| H | Rear Setback (min) - Non-Through Lot - Through Lot |
50' 150' | ||
| Accessory Building Placement | ||||
| I | Front Setback (min) | 100' | ||
| J | Side Setback (min) | 40' | ||
| K | Corner Side Setback (min) | 150' | ||
Rear Setback (min) - Standard Lot, 15' or Greater in Height - Through Lot, 15' or Greater in Height | 25' 30' | |||
| L | Accessory Building Placement for Structures Under 15' in Height | |||
| Front Setback (min) | 100' | |||
| Side Setback (min) | 20' | |||
| Corner Side Setback (min) | 150' | |||
Rear Setback - Standard Lot - Through Lot |
10' 30' | |||
| Principal & Accessory Building Height | ||||
| M | Height (max) | 45' | ||
| Utilities | ||||
Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Not required, unless required by County Code Sec. 18-60. | |||
Notes:
| ||||
| Figure 19.2-9.1, RC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Figure 19.2-9.1, RC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Figure 19.2-9.1, RC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Figure 19.2-9.1, RC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Provisions Related to the RC District | |
|---|---|
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Dimensional Standards | Sec. 19.2-37 |
| Landscaping and Screening | Sec. 19.2-41 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
| Provisions Related to the RC District | |
|---|---|
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Dimensional Standards | Sec. 19.2-37 |
| Landscaping and Screening | Sec. 19.2-41 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
| Provisions Related to the RC District | |
|---|---|
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Dimensional Standards | Sec. 19.2-37 |
| Landscaping and Screening | Sec. 19.2-41 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
| Provisions Related to the RC District | |
|---|---|
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Dimensional Standards | Sec. 19.2-37 |
| Landscaping and Screening | Sec. 19.2-41 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
(ZO-2025-002, Relative to Auto Sales, Required Utility Connections, and Site Plans, adopted 12/17/2025, effective 01/01/2026)
Purpose. The Semi-Rural Neighborhood (SR) District provides for residential development on larger lot sizes ranging from two acres to half-acre. The role of the SR District is to transition from the rural areas to developing areas of the County by encouraging developments that incorporate environmental features and green areas as key components.
| Table 19.2-10.1, Semi-Rural Neighborhood (SR) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf = square feet ' = feet | ||||||||
| Key | Development | Base | Option 1 | Option 2 | ||||
| Neighborhood Type | Single-Family | Single-Family | Single-Family | |||||
| -- | Amenity Space (min) | -- | -- | -- | ||||
| Lot Standards | ||||||||
| A | Lot Area (min) [1] | 87,120 sf. | 40,000 sf. | 21,780 sf. | ||||
| B | Lot Width (min) | 150' | 150' | 120' | ||||
| C | Road Frontage (min) - Cul-de-sac or Loop Road - Other Road |
30' 50' |
30' 50' |
30' 50' | ||||
| D | Building Coverage (max) | 20% | 20% | 25% | ||||
| Building Standards | ||||||||
| Principal Building Placement [2] | ||||||||
| E | Front Setback (min) [3] - Street - Cul-de-sac |
75' 25' |
60' 25' |
50' 25' | ||||
| F | Side Setback (min) | 30' | 20' | 15' | ||||
| G | Corner Side Setback (min) - Through Lot, Lot Back-to-Back or Lot Backing to Amenity Space - Other |
30' 75' |
30' 55' |
25' 45' | ||||
| H | Rear Setback (min) - Non-Through Lot - Through Lot |
50' 75' |
50' 60' |
40' 50' | ||||
| Accessory Building Placement for Structures 15' in Height or Greater, Not to Exceed 30' in Height | ||||||||
| I | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | Same as side setback of the principal building placement | ||||||
| K | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| L | Rear Setback (min) | Half of the rear setback of the principal building placement | ||||||
| Accessory Building Placement for Structures Under 15' in Height | ||||||||
| M | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| N | Side Setback (min) | Half of the side setback of the principal building placement | ||||||
| O | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| P | Rear Setback (min) - Non-through Lot - Through Lot |
10' 30' | ||||||
| Principal Building Height | ||||||||
| Q | Height (max) | 45' | 45' | 45' | ||||
| Utilities | ||||||||
Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Permitted only if approved by the Director of Utilities, or required by County Code Sec. 18-60. |
Water Required unless approved for an exception by County Code Sec. 18-61; Wastewater Not Required, unless required by County Code Sec. 18-60. |
Required, unless approved for an exception by County Code Sec. 18-61.
| |||||
Notes:
| ||||||||
| Table 19.2-10.1, Semi-Rural Neighborhood (SR) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf = square feet ' = feet | ||||||||
| Key | Development | Base | Option 1 | Option 2 | ||||
| Neighborhood Type | Single-Family | Single-Family | Single-Family | |||||
| -- | Amenity Space (min) | -- | -- | -- | ||||
| Lot Standards | ||||||||
| A | Lot Area (min) [1] | 87,120 sf. | 40,000 sf. | 21,780 sf. | ||||
| B | Lot Width (min) | 150' | 150' | 120' | ||||
| C | Road Frontage (min) - Cul-de-sac or Loop Road - Other Road |
30' 50' |
30' 50' |
30' 50' | ||||
| D | Building Coverage (max) | 20% | 20% | 25% | ||||
| Building Standards | ||||||||
| Principal Building Placement [2] | ||||||||
| E | Front Setback (min) [3] - Street - Cul-de-sac |
75' 25' |
60' 25' |
50' 25' | ||||
| F | Side Setback (min) | 30' | 20' | 15' | ||||
| G | Corner Side Setback (min) - Through Lot, Lot Back-to-Back or Lot Backing to Amenity Space - Other |
30' 75' |
30' 55' |
25' 45' | ||||
| H | Rear Setback (min) - Non-Through Lot - Through Lot |
50' 75' |
50' 60' |
40' 50' | ||||
| Accessory Building Placement for Structures 15' in Height or Greater, Not to Exceed 30' in Height | ||||||||
| I | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | Same as side setback of the principal building placement | ||||||
| K | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| L | Rear Setback (min) | Half of the rear setback of the principal building placement | ||||||
| Accessory Building Placement for Structures Under 15' in Height | ||||||||
| M | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| N | Side Setback (min) | Half of the side setback of the principal building placement | ||||||
| O | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| P | Rear Setback (min) - Non-through Lot - Through Lot |
10' 30' | ||||||
| Principal Building Height | ||||||||
| Q | Height (max) | 45' | 45' | 45' | ||||
| Utilities | ||||||||
Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Permitted only if approved by the Director of Utilities, or required by County Code Sec. 18-60. |
Water Required unless approved for an exception by County Code Sec. 18-61; Wastewater Not Required, unless required by County Code Sec. 18-60. |
Required, unless approved for an exception by County Code Sec. 18-61.
| |||||
Notes:
| ||||||||
| Table 19.2-10.1, Semi-Rural Neighborhood (SR) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf = square feet ' = feet | ||||||||
| Key | Development | Base | Option 1 | Option 2 | ||||
| Neighborhood Type | Single-Family | Single-Family | Single-Family | |||||
| -- | Amenity Space (min) | -- | -- | -- | ||||
| Lot Standards | ||||||||
| A | Lot Area (min) [1] | 87,120 sf. | 40,000 sf. | 21,780 sf. | ||||
| B | Lot Width (min) | 150' | 150' | 120' | ||||
| C | Road Frontage (min) - Cul-de-sac or Loop Road - Other Road |
30' 50' |
30' 50' |
30' 50' | ||||
| D | Building Coverage (max) | 20% | 20% | 25% | ||||
| Building Standards | ||||||||
| Principal Building Placement [2] | ||||||||
| E | Front Setback (min) [3] - Street - Cul-de-sac |
75' 25' |
60' 25' |
50' 25' | ||||
| F | Side Setback (min) | 30' | 20' | 15' | ||||
| G | Corner Side Setback (min) - Through Lot, Lot Back-to-Back or Lot Backing to Amenity Space - Other |
30' 75' |
30' 55' |
25' 45' | ||||
| H | Rear Setback (min) - Non-Through Lot - Through Lot |
50' 75' |
50' 60' |
40' 50' | ||||
| Accessory Building Placement for Structures 15' in Height or Greater, Not to Exceed 30' in Height | ||||||||
| I | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | Same as side setback of the principal building placement | ||||||
| K | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| L | Rear Setback (min) | Half of the rear setback of the principal building placement | ||||||
| Accessory Building Placement for Structures Under 15' in Height | ||||||||
| M | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| N | Side Setback (min) | Half of the side setback of the principal building placement | ||||||
| O | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| P | Rear Setback (min) - Non-through Lot - Through Lot |
10' 30' | ||||||
| Principal Building Height | ||||||||
| Q | Height (max) | 45' | 45' | 45' | ||||
| Utilities | ||||||||
Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Permitted only if approved by the Director of Utilities, or required by County Code Sec. 18-60. |
Water Required unless approved for an exception by County Code Sec. 18-61; Wastewater Not Required, unless required by County Code Sec. 18-60. |
Required, unless approved for an exception by County Code Sec. 18-61.
| |||||
Notes:
| ||||||||
| Table 19.2-10.1, Semi-Rural Neighborhood (SR) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf = square feet ' = feet | ||||||||
| Key | Development | Base | Option 1 | Option 2 | ||||
| Neighborhood Type | Single-Family | Single-Family | Single-Family | |||||
| -- | Amenity Space (min) | -- | -- | -- | ||||
| Lot Standards | ||||||||
| A | Lot Area (min) [1] | 87,120 sf. | 40,000 sf. | 21,780 sf. | ||||
| B | Lot Width (min) | 150' | 150' | 120' | ||||
| C | Road Frontage (min) - Cul-de-sac or Loop Road - Other Road |
30' 50' |
30' 50' |
30' 50' | ||||
| D | Building Coverage (max) | 20% | 20% | 25% | ||||
| Building Standards | ||||||||
| Principal Building Placement [2] | ||||||||
| E | Front Setback (min) [3] - Street - Cul-de-sac |
75' 25' |
60' 25' |
50' 25' | ||||
| F | Side Setback (min) | 30' | 20' | 15' | ||||
| G | Corner Side Setback (min) - Through Lot, Lot Back-to-Back or Lot Backing to Amenity Space - Other |
30' 75' |
30' 55' |
25' 45' | ||||
| H | Rear Setback (min) - Non-Through Lot - Through Lot |
50' 75' |
50' 60' |
40' 50' | ||||
| Accessory Building Placement for Structures 15' in Height or Greater, Not to Exceed 30' in Height | ||||||||
| I | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | Same as side setback of the principal building placement | ||||||
| K | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| L | Rear Setback (min) | Half of the rear setback of the principal building placement | ||||||
| Accessory Building Placement for Structures Under 15' in Height | ||||||||
| M | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| N | Side Setback (min) | Half of the side setback of the principal building placement | ||||||
| O | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| P | Rear Setback (min) - Non-through Lot - Through Lot |
10' 30' | ||||||
| Principal Building Height | ||||||||
| Q | Height (max) | 45' | 45' | 45' | ||||
| Utilities | ||||||||
Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Permitted only if approved by the Director of Utilities, or required by County Code Sec. 18-60. |
Water Required unless approved for an exception by County Code Sec. 18-61; Wastewater Not Required, unless required by County Code Sec. 18-60. |
Required, unless approved for an exception by County Code Sec. 18-61.
| |||||
Notes:
| ||||||||
| Figure 19.2-10.1, SR Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-10.1, SR Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-10.1, SR Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-10.1, SR Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Provisions Related to the SR District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Dimensional Standards | Sec. 19.2-37 |
| Landscaping and Screening | Sec. 19.2-41 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
(ZO-2025-002, Relative to Auto Sales, Required Utility Connections, and Site Plans, adopted 12/17/2025, effective 01/01/2026)
Purpose. The Suburban Community (SC) District provides for quality single-family neighborhoods in the developing areas of the County and as infill opportunities within established areas of the County. Developments in the SC District should feature connectivity to employment centers, services, amenities, and other neighborhoods.
| Table 19.2-11.1, Suburban Community (SC) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre sf. = square feet ' = feet | ||||||||
| Key | Development | Base | Option 1 | Option 2 | ||||
| Neighborhood Type | Single-Family | Single-Family | Single-Family | |||||
| -- | Amenity Space (min) | 0% | 7.5% | 10% | ||||
| Strategic Amenity Space (min) | -- | 0.01 ac/du | 0.01 ac/du | |||||
| Lot Standards | ||||||||
| A | Lot Area (min) | 14,500 sf. | 11,000 sf. | 8,000 sf. | ||||
| B | Lot Width (min) | 100' | 90' | 75' | ||||
| C | Road Frontage (min) - Cul-de-sac or Loop Road - Other Road |
30' 50' |
30' 50' |
30' 50' | ||||
| D | Building Coverage (max) | 25% | 35% | 40% | ||||
| Building Standards | ||||||||
| Principal Building Placement [1] | ||||||||
| E | Front Setback (min) [2] - Street - Cul-de-sac |
30' 25' |
30' 25' |
30' 25' | ||||
| F | Side Setback (min) | 15' [3] | 10' | 7.5' | ||||
G
| Corner Side Setback (min) - Through Lot, Lot Back-to-Back or Lot Backing to Amenity Space - Other |
20' 35' |
20' 30' |
15' 25' | ||||
| H | Rear Setback (min) - Non-through Lot - Through Lot |
25' 40' |
25' 30' |
25' 30' | ||||
| Accessory Building Placement for Structures 15' in Height or Greater, Not to Exceed 30' | ||||||||
| I | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | Same as side setback of the principal building placement | ||||||
| K | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| L | Rear Setback (min) | Half of the rear setback of the principal building placement | ||||||
| Accessory Building Placement for Structures Under 15' in Height | ||||||||
| M | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| N | Side Setback (min) | Half of the side setback of the principal building placement | ||||||
| O | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| P | Rear Setback (min) - Non-through lot - Through lot |
30' | ||||||
| Principal Building Height | ||||||||
| Q | Height (max) | 45' | 45' | 45' | ||||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | ||||
Notes:
| ||||||||
| Table 19.2-11.1, Suburban Community (SC) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre sf. = square feet ' = feet | ||||||||
| Key | Development | Base | Option 1 | Option 2 | ||||
| Neighborhood Type | Single-Family | Single-Family | Single-Family | |||||
| -- | Amenity Space (min) | 0% | 7.5% | 10% | ||||
| Strategic Amenity Space (min) | -- | 0.01 ac/du | 0.01 ac/du | |||||
| Lot Standards | ||||||||
| A | Lot Area (min) | 14,500 sf. | 11,000 sf. | 8,000 sf. | ||||
| B | Lot Width (min) | 100' | 90' | 75' | ||||
| C | Road Frontage (min) - Cul-de-sac or Loop Road - Other Road |
30' 50' |
30' 50' |
30' 50' | ||||
| D | Building Coverage (max) | 25% | 35% | 40% | ||||
| Building Standards | ||||||||
| Principal Building Placement [1] | ||||||||
| E | Front Setback (min) [2] - Street - Cul-de-sac |
30' 25' |
30' 25' |
30' 25' | ||||
| F | Side Setback (min) | 15' [3] | 10' | 7.5' | ||||
G
| Corner Side Setback (min) - Through Lot, Lot Back-to-Back or Lot Backing to Amenity Space - Other |
20' 35' |
20' 30' |
15' 25' | ||||
| H | Rear Setback (min) - Non-through Lot - Through Lot |
25' 40' |
25' 30' |
25' 30' | ||||
| Accessory Building Placement for Structures 15' in Height or Greater, Not to Exceed 30' | ||||||||
| I | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | Same as side setback of the principal building placement | ||||||
| K | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| L | Rear Setback (min) | Half of the rear setback of the principal building placement | ||||||
| Accessory Building Placement for Structures Under 15' in Height | ||||||||
| M | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| N | Side Setback (min) | Half of the side setback of the principal building placement | ||||||
| O | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| P | Rear Setback (min) - Non-through lot - Through lot |
30' | ||||||
| Principal Building Height | ||||||||
| Q | Height (max) | 45' | 45' | 45' | ||||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | ||||
Notes:
| ||||||||
| Table 19.2-11.1, Suburban Community (SC) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre sf. = square feet ' = feet | ||||||||
| Key | Development | Base | Option 1 | Option 2 | ||||
| Neighborhood Type | Single-Family | Single-Family | Single-Family | |||||
| -- | Amenity Space (min) | 0% | 7.5% | 10% | ||||
| Strategic Amenity Space (min) | -- | 0.01 ac/du | 0.01 ac/du | |||||
| Lot Standards | ||||||||
| A | Lot Area (min) | 14,500 sf. | 11,000 sf. | 8,000 sf. | ||||
| B | Lot Width (min) | 100' | 90' | 75' | ||||
| C | Road Frontage (min) - Cul-de-sac or Loop Road - Other Road |
30' 50' |
30' 50' |
30' 50' | ||||
| D | Building Coverage (max) | 25% | 35% | 40% | ||||
| Building Standards | ||||||||
| Principal Building Placement [1] | ||||||||
| E | Front Setback (min) [2] - Street - Cul-de-sac |
30' 25' |
30' 25' |
30' 25' | ||||
| F | Side Setback (min) | 15' [3] | 10' | 7.5' | ||||
G
| Corner Side Setback (min) - Through Lot, Lot Back-to-Back or Lot Backing to Amenity Space - Other |
20' 35' |
20' 30' |
15' 25' | ||||
| H | Rear Setback (min) - Non-through Lot - Through Lot |
25' 40' |
25' 30' |
25' 30' | ||||
| Accessory Building Placement for Structures 15' in Height or Greater, Not to Exceed 30' | ||||||||
| I | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | Same as side setback of the principal building placement | ||||||
| K | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| L | Rear Setback (min) | Half of the rear setback of the principal building placement | ||||||
| Accessory Building Placement for Structures Under 15' in Height | ||||||||
| M | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| N | Side Setback (min) | Half of the side setback of the principal building placement | ||||||
| O | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| P | Rear Setback (min) - Non-through lot - Through lot |
30' | ||||||
| Principal Building Height | ||||||||
| Q | Height (max) | 45' | 45' | 45' | ||||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | ||||
Notes:
| ||||||||
| Table 19.2-11.1, Suburban Community (SC) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre sf. = square feet ' = feet | ||||||||
| Key | Development | Base | Option 1 | Option 2 | ||||
| Neighborhood Type | Single-Family | Single-Family | Single-Family | |||||
| -- | Amenity Space (min) | 0% | 7.5% | 10% | ||||
| Strategic Amenity Space (min) | -- | 0.01 ac/du | 0.01 ac/du | |||||
| Lot Standards | ||||||||
| A | Lot Area (min) | 14,500 sf. | 11,000 sf. | 8,000 sf. | ||||
| B | Lot Width (min) | 100' | 90' | 75' | ||||
| C | Road Frontage (min) - Cul-de-sac or Loop Road - Other Road |
30' 50' |
30' 50' |
30' 50' | ||||
| D | Building Coverage (max) | 25% | 35% | 40% | ||||
| Building Standards | ||||||||
| Principal Building Placement [1] | ||||||||
| E | Front Setback (min) [2] - Street - Cul-de-sac |
30' 25' |
30' 25' |
30' 25' | ||||
| F | Side Setback (min) | 15' [3] | 10' | 7.5' | ||||
G
| Corner Side Setback (min) - Through Lot, Lot Back-to-Back or Lot Backing to Amenity Space - Other |
20' 35' |
20' 30' |
15' 25' | ||||
| H | Rear Setback (min) - Non-through Lot - Through Lot |
25' 40' |
25' 30' |
25' 30' | ||||
| Accessory Building Placement for Structures 15' in Height or Greater, Not to Exceed 30' | ||||||||
| I | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | Same as side setback of the principal building placement | ||||||
| K | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| L | Rear Setback (min) | Half of the rear setback of the principal building placement | ||||||
| Accessory Building Placement for Structures Under 15' in Height | ||||||||
| M | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| N | Side Setback (min) | Half of the side setback of the principal building placement | ||||||
| O | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| P | Rear Setback (min) - Non-through lot - Through lot |
30' | ||||||
| Principal Building Height | ||||||||
| Q | Height (max) | 45' | 45' | 45' | ||||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | ||||
Notes:
| ||||||||
| Figure 19.2-11.1, SC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-11.1, SC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-11.1, SC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-11.1, SC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Provisions Related to the SC District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Amenity Space | Sec. 19.2-34 |
| Dimension Standards | Sec. 19.2-37 |
| Landscaping and Screening | Sec. 19.2-41 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
(ZO-2025-002, Relative to Auto Sales, Required Utility Connections, and Site Plans, adopted 12/17/2025, effective 01/01/2026)
Purpose. The Semi-Urban Neighborhood (SU) District provides for single-family dwellings on smaller lots. The role of the SU District is to provide a transition from corridors and more intensely developed areas to single-family neighborhoods and may be appropriate in areas where environmental constraints make achieving Comprehensive Plan densities difficult. Developments in the SU District are encouraged to integrate affordable housing with market-rate development where appropriate.
| Table 19.2-12.1, Semi-Urban Neighborhood (SU) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||||||
| Development | Base | Option 1 | Option 2 | |||||
| Key | Neighborhood Type | Single-Family | Single-Family | Single-Family | ||||
| -- | Amenity Space (min) [1] | 10% | 12.5% | 15% | ||||
| Strategic Amenity Space (min) | 0.01 ac/du | 0.01 ac/du | 0.01 ac/du | |||||
| Lot Standards | ||||||||
| A | Lot Area (min) | 7,500 sf. | 6,000 sf. | 4,500 sf. | ||||
| B | Lot Width (min) | 75' | 60' | 45' | ||||
| C | Road Frontage (min) [2] - Cul-de-sac or loop road - Other road |
25' 50' |
25' 40' |
25' 25' | ||||
| D | Building coverage (max) [1] | 40% | 50% | 60% | ||||
| Building Standards | ||||||||
| Principal Building Placement [3] | ||||||||
| E | Front Setback (min) [1] - Street - Cul-de-sac |
25' 25' |
25' 25' |
25' 25' | ||||
| F | Side Setback (min) | 7.5' | 5' | 5' | ||||
| G | Corner Side Setback (min) - Through Lot, Lot Back-to-Back or Lot Backing to Amenity Space - Other |
15' 25' |
10' 20' |
10' 20' | ||||
| H | Rear Setback (min) - Non-through lot - Through lot |
25' 30' |
20' 25' |
15' 20' | ||||
| Accessory Building Placement for Structures 15' in Height or greater, not to exceed 30' in height | ||||||||
| I | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | Same as side setback of the primary building placement | ||||||
| K | Corner Side Setback (min) | Same as the front setback of the primary building placement | ||||||
| L | Rear Setback (min) | Half of the rear setback of the primary building placement | ||||||
| Accessory Building Placement for Structures under 15' in height | ||||||||
| M | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| N | Side Setback (min) | 3.75' | ||||||
| O | Corner Side Setback (min) | Same as front setback of the primary building placement | ||||||
| P | Rear Setback (min) - Non-through lot - Through lot |
5' 30 | ||||||
| Building Height | ||||||||
| Q | Height (max) | 45' | 45' | 45' | ||||
| Access and Parking [4] | ||||||||
| R | Parking Location | On-street or on-site | On-street, on-site | On-street, or on-site | ||||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | ||||
Notes:
| ||||||||
| Table 19.2-12.1, Semi-Urban Neighborhood (SU) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||||||
| Development | Base | Option 1 | Option 2 | |||||
| Key | Neighborhood Type | Single-Family | Single-Family | Single-Family | ||||
| -- | Amenity Space (min) [1] | 10% | 12.5% | 15% | ||||
| Strategic Amenity Space (min) | 0.01 ac/du | 0.01 ac/du | 0.01 ac/du | |||||
| Lot Standards | ||||||||
| A | Lot Area (min) | 7,500 sf. | 6,000 sf. | 4,500 sf. | ||||
| B | Lot Width (min) | 75' | 60' | 45' | ||||
| C | Road Frontage (min) [2] - Cul-de-sac or loop road - Other road |
25' 50' |
25' 40' |
25' 25' | ||||
| D | Building coverage (max) [1] | 40% | 50% | 60% | ||||
| Building Standards | ||||||||
| Principal Building Placement [3] | ||||||||
| E | Front Setback (min) [1] - Street - Cul-de-sac |
25' 25' |
25' 25' |
25' 25' | ||||
| F | Side Setback (min) | 7.5' | 5' | 5' | ||||
| G | Corner Side Setback (min) - Through Lot, Lot Back-to-Back or Lot Backing to Amenity Space - Other |
15' 25' |
10' 20' |
10' 20' | ||||
| H | Rear Setback (min) - Non-through lot - Through lot |
25' 30' |
20' 25' |
15' 20' | ||||
| Accessory Building Placement for Structures 15' in Height or greater, not to exceed 30' in height | ||||||||
| I | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | Same as side setback of the primary building placement | ||||||
| K | Corner Side Setback (min) | Same as the front setback of the primary building placement | ||||||
| L | Rear Setback (min) | Half of the rear setback of the primary building placement | ||||||
| Accessory Building Placement for Structures under 15' in height | ||||||||
| M | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| N | Side Setback (min) | 3.75' | ||||||
| O | Corner Side Setback (min) | Same as front setback of the primary building placement | ||||||
| P | Rear Setback (min) - Non-through lot - Through lot |
5' 30 | ||||||
| Building Height | ||||||||
| Q | Height (max) | 45' | 45' | 45' | ||||
| Access and Parking [4] | ||||||||
| R | Parking Location | On-street or on-site | On-street, on-site | On-street, or on-site | ||||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | ||||
Notes:
| ||||||||
| Table 19.2-12.1, Semi-Urban Neighborhood (SU) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||||||
| Development | Base | Option 1 | Option 2 | |||||
| Key | Neighborhood Type | Single-Family | Single-Family | Single-Family | ||||
| -- | Amenity Space (min) [1] | 10% | 12.5% | 15% | ||||
| Strategic Amenity Space (min) | 0.01 ac/du | 0.01 ac/du | 0.01 ac/du | |||||
| Lot Standards | ||||||||
| A | Lot Area (min) | 7,500 sf. | 6,000 sf. | 4,500 sf. | ||||
| B | Lot Width (min) | 75' | 60' | 45' | ||||
| C | Road Frontage (min) [2] - Cul-de-sac or loop road - Other road |
25' 50' |
25' 40' |
25' 25' | ||||
| D | Building coverage (max) [1] | 40% | 50% | 60% | ||||
| Building Standards | ||||||||
| Principal Building Placement [3] | ||||||||
| E | Front Setback (min) [1] - Street - Cul-de-sac |
25' 25' |
25' 25' |
25' 25' | ||||
| F | Side Setback (min) | 7.5' | 5' | 5' | ||||
| G | Corner Side Setback (min) - Through Lot, Lot Back-to-Back or Lot Backing to Amenity Space - Other |
15' 25' |
10' 20' |
10' 20' | ||||
| H | Rear Setback (min) - Non-through lot - Through lot |
25' 30' |
20' 25' |
15' 20' | ||||
| Accessory Building Placement for Structures 15' in Height or greater, not to exceed 30' in height | ||||||||
| I | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | Same as side setback of the primary building placement | ||||||
| K | Corner Side Setback (min) | Same as the front setback of the primary building placement | ||||||
| L | Rear Setback (min) | Half of the rear setback of the primary building placement | ||||||
| Accessory Building Placement for Structures under 15' in height | ||||||||
| M | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| N | Side Setback (min) | 3.75' | ||||||
| O | Corner Side Setback (min) | Same as front setback of the primary building placement | ||||||
| P | Rear Setback (min) - Non-through lot - Through lot |
5' 30 | ||||||
| Building Height | ||||||||
| Q | Height (max) | 45' | 45' | 45' | ||||
| Access and Parking [4] | ||||||||
| R | Parking Location | On-street or on-site | On-street, on-site | On-street, or on-site | ||||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | ||||
Notes:
| ||||||||
| Table 19.2-12.1, Semi-Urban Neighborhood (SU) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||||||
| Development | Base | Option 1 | Option 2 | |||||
| Key | Neighborhood Type | Single-Family | Single-Family | Single-Family | ||||
| -- | Amenity Space (min) [1] | 10% | 12.5% | 15% | ||||
| Strategic Amenity Space (min) | 0.01 ac/du | 0.01 ac/du | 0.01 ac/du | |||||
| Lot Standards | ||||||||
| A | Lot Area (min) | 7,500 sf. | 6,000 sf. | 4,500 sf. | ||||
| B | Lot Width (min) | 75' | 60' | 45' | ||||
| C | Road Frontage (min) [2] - Cul-de-sac or loop road - Other road |
25' 50' |
25' 40' |
25' 25' | ||||
| D | Building coverage (max) [1] | 40% | 50% | 60% | ||||
| Building Standards | ||||||||
| Principal Building Placement [3] | ||||||||
| E | Front Setback (min) [1] - Street - Cul-de-sac |
25' 25' |
25' 25' |
25' 25' | ||||
| F | Side Setback (min) | 7.5' | 5' | 5' | ||||
| G | Corner Side Setback (min) - Through Lot, Lot Back-to-Back or Lot Backing to Amenity Space - Other |
15' 25' |
10' 20' |
10' 20' | ||||
| H | Rear Setback (min) - Non-through lot - Through lot |
25' 30' |
20' 25' |
15' 20' | ||||
| Accessory Building Placement for Structures 15' in Height or greater, not to exceed 30' in height | ||||||||
| I | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | Same as side setback of the primary building placement | ||||||
| K | Corner Side Setback (min) | Same as the front setback of the primary building placement | ||||||
| L | Rear Setback (min) | Half of the rear setback of the primary building placement | ||||||
| Accessory Building Placement for Structures under 15' in height | ||||||||
| M | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| N | Side Setback (min) | 3.75' | ||||||
| O | Corner Side Setback (min) | Same as front setback of the primary building placement | ||||||
| P | Rear Setback (min) - Non-through lot - Through lot |
5' 30 | ||||||
| Building Height | ||||||||
| Q | Height (max) | 45' | 45' | 45' | ||||
| Access and Parking [4] | ||||||||
| R | Parking Location | On-street or on-site | On-street, on-site | On-street, or on-site | ||||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | ||||
Notes:
| ||||||||
| Figure 19.2-12.1, SU Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-12.1, SU Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-12.1, SU Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-12.1, SU Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Provisions Related to the SU District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Amenity Space | Sec. 19.2-34 |
| Dimensional Standards | Sec. 19.2-37 |
| Landscaping and Screening | Sec. 19.2-41 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
(ZO-2025-002, Relative to Auto Sales, Required Utility Connections, and Site Plans, adopted 12/17/2025, effective 01/01/2026)
Purpose. The Transition Residential (TR) District provides for single-family attached dwellings and low-rise apartment buildings and complexes. The bulk and scale of development is designed for transitioning from suburban and semi-urban neighborhoods to urban neighborhoods, mixed-use centers, and major arterial and highway corridors. The building types include townhomes and multi-family configurations that may be compatible with single-family neighborhoods for areas nearest non-residential and mixed-use development and major corridors. The amount of amenity space is commensurate with density and may be used for buffering adjacent uses that share a common property line.
| Table 19.2-13.1, Transition Residential (TR) Lot and Building Standards [1] | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| ac = acre ' = feet | |||||||||
| Development | Base | Option 1 | |||||||
| Key | Neighborhood Type | Suburban Townhouse | Multi-Family/ Condominium | ||||||
| Vehicle Access Type | Front Loaded | Rear Loaded/Common Parking | Street | ||||||
| -- | Dwelling units per row (max) | 8 | 10 | -- | |||||
| -- | Project Size (min) | 5.0 ac | 5.0 ac | 10.0 ac | |||||
| -- | Amenity Space (min) | 20% | 10% | 15% | |||||
| Strategic Amenity Space (min) | 30% of required AS | 30% of required AS | 50% of required AS | ||||||
| Lot Standards | |||||||||
| A | Lot Depth (min) | 70' | 70' | -- | |||||
| B | Lot Width (min) | 19' [2] | 16' | -- | |||||
| C | Road Frontage | [3] | [3] | -- | |||||
| Building Standards | |||||||||
| Townhouse Building Placement (Principal and Accessory) [4] | |||||||||
| D | Front Setback (min) | 20' [5] | 10' | -- | |||||
| E | Side Setback for end unit (min) | 10' | 10' | -- | |||||
| F | Corner Side Setback (min) - Principal - Accessory |
15' 5' |
10' 5' | -- | |||||
| G | Rear Setback (min) - Principal - Accessory |
20' 5' |
20' [6] 5' | -- | |||||
| Multifamily Building Placement (Principal and Accessory)/Required Perimeter Landscaping | |||||||||
| H | Project Property Line Setback (min) | -- | -- | 30'/C | |||||
| I | Road Setback (min) - Arterial - Collector/All other public roads | -- | -- |
50'/C 25'/C | |||||
| J | Internal Roads and Private Pavement/Parking Spaces (min) | -- | -- |
15' | |||||
| Building Height | |||||||||
| K | Height (max) |
65' |
65' |
65' | |||||
| Access and Parking/Required Perimeter Landscaping | |||||||||
| L | Parking Location |
|
| Common Lot | |||||
| M | Parking pad length, exclusive of sidewalks (min) | 20' | -- | -- | |||||
| N | Parking Lot Setback (min) - Arterial - Collector - All other roads - Lots with dwellings/exterior property lines | See Sec. 19.2-35
15' 10' [9] |
See Sec. 19.2-35
15' 10' [9]
| 50'/C 25'/C [8] 25'/C 25'/C | |||||
| -- | Number of Access Points - 50 units or fewer - 51 or more units | See Sec. 17.1-84 | See Sec. 17.1-84 |
1 2 | |||||
| Utilities | |||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | ||||||
| Building Design | |||||||||
| O | Total garage door width as a percent of total building row length (max) | 60% | -- | -- | |||||
Notes:
| |||||||||
| Table 19.2-13.1, Transition Residential (TR) Lot and Building Standards [1] | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| ac = acre ' = feet | |||||||||
| Development | Base | Option 1 | |||||||
| Key | Neighborhood Type | Suburban Townhouse | Multi-Family/ Condominium | ||||||
| Vehicle Access Type | Front Loaded | Rear Loaded/Common Parking | Street | ||||||
| -- | Dwelling units per row (max) | 8 | 10 | -- | |||||
| -- | Project Size (min) | 5.0 ac | 5.0 ac | 10.0 ac | |||||
| -- | Amenity Space (min) | 20% | 10% | 15% | |||||
| Strategic Amenity Space (min) | 30% of required AS | 30% of required AS | 50% of required AS | ||||||
| Lot Standards | |||||||||
| A | Lot Depth (min) | 70' | 70' | -- | |||||
| B | Lot Width (min) | 19' [2] | 16' | -- | |||||
| C | Road Frontage | [3] | [3] | -- | |||||
| Building Standards | |||||||||
| Townhouse Building Placement (Principal and Accessory) [4] | |||||||||
| D | Front Setback (min) | 20' [5] | 10' | -- | |||||
| E | Side Setback for end unit (min) | 10' | 10' | -- | |||||
| F | Corner Side Setback (min) - Principal - Accessory |
15' 5' |
10' 5' | -- | |||||
| G | Rear Setback (min) - Principal - Accessory |
20' 5' |
20' [6] 5' | -- | |||||
| Multifamily Building Placement (Principal and Accessory)/Required Perimeter Landscaping | |||||||||
| H | Project Property Line Setback (min) | -- | -- | 30'/C | |||||
| I | Road Setback (min) - Arterial - Collector/All other public roads | -- | -- |
50'/C 25'/C | |||||
| J | Internal Roads and Private Pavement/Parking Spaces (min) | -- | -- |
15' | |||||
| Building Height | |||||||||
| K | Height (max) |
65' |
65' |
65' | |||||
| Access and Parking/Required Perimeter Landscaping | |||||||||
| L | Parking Location |
|
| Common Lot | |||||
| M | Parking pad length, exclusive of sidewalks (min) | 20' | -- | -- | |||||
| N | Parking Lot Setback (min) - Arterial - Collector - All other roads - Lots with dwellings/exterior property lines | See Sec. 19.2-35
15' 10' [9] |
See Sec. 19.2-35
15' 10' [9]
| 50'/C 25'/C [8] 25'/C 25'/C | |||||
| -- | Number of Access Points - 50 units or fewer - 51 or more units | See Sec. 17.1-84 | See Sec. 17.1-84 |
1 2 | |||||
| Utilities | |||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | ||||||
| Building Design | |||||||||
| O | Total garage door width as a percent of total building row length (max) | 60% | -- | -- | |||||
Notes:
| |||||||||
| Table 19.2-13.1, Transition Residential (TR) Lot and Building Standards [1] | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| ac = acre ' = feet | |||||||||
| Development | Base | Option 1 | |||||||
| Key | Neighborhood Type | Suburban Townhouse | Multi-Family/ Condominium | ||||||
| Vehicle Access Type | Front Loaded | Rear Loaded/Common Parking | Street | ||||||
| -- | Dwelling units per row (max) | 8 | 10 | -- | |||||
| -- | Project Size (min) | 5.0 ac | 5.0 ac | 10.0 ac | |||||
| -- | Amenity Space (min) | 20% | 10% | 15% | |||||
| Strategic Amenity Space (min) | 30% of required AS | 30% of required AS | 50% of required AS | ||||||
| Lot Standards | |||||||||
| A | Lot Depth (min) | 70' | 70' | -- | |||||
| B | Lot Width (min) | 19' [2] | 16' | -- | |||||
| C | Road Frontage | [3] | [3] | -- | |||||
| Building Standards | |||||||||
| Townhouse Building Placement (Principal and Accessory) [4] | |||||||||
| D | Front Setback (min) | 20' [5] | 10' | -- | |||||
| E | Side Setback for end unit (min) | 10' | 10' | -- | |||||
| F | Corner Side Setback (min) - Principal - Accessory |
15' 5' |
10' 5' | -- | |||||
| G | Rear Setback (min) - Principal - Accessory |
20' 5' |
20' [6] 5' | -- | |||||
| Multifamily Building Placement (Principal and Accessory)/Required Perimeter Landscaping | |||||||||
| H | Project Property Line Setback (min) | -- | -- | 30'/C | |||||
| I | Road Setback (min) - Arterial - Collector/All other public roads | -- | -- |
50'/C 25'/C | |||||
| J | Internal Roads and Private Pavement/Parking Spaces (min) | -- | -- |
15' | |||||
| Building Height | |||||||||
| K | Height (max) |
65' |
65' |
65' | |||||
| Access and Parking/Required Perimeter Landscaping | |||||||||
| L | Parking Location |
|
| Common Lot | |||||
| M | Parking pad length, exclusive of sidewalks (min) | 20' | -- | -- | |||||
| N | Parking Lot Setback (min) - Arterial - Collector - All other roads - Lots with dwellings/exterior property lines | See Sec. 19.2-35
15' 10' [9] |
See Sec. 19.2-35
15' 10' [9]
| 50'/C 25'/C [8] 25'/C 25'/C | |||||
| -- | Number of Access Points - 50 units or fewer - 51 or more units | See Sec. 17.1-84 | See Sec. 17.1-84 |
1 2 | |||||
| Utilities | |||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | ||||||
| Building Design | |||||||||
| O | Total garage door width as a percent of total building row length (max) | 60% | -- | -- | |||||
Notes:
| |||||||||
| Table 19.2-13.1, Transition Residential (TR) Lot and Building Standards [1] | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| ac = acre ' = feet | |||||||||
| Development | Base | Option 1 | |||||||
| Key | Neighborhood Type | Suburban Townhouse | Multi-Family/ Condominium | ||||||
| Vehicle Access Type | Front Loaded | Rear Loaded/Common Parking | Street | ||||||
| -- | Dwelling units per row (max) | 8 | 10 | -- | |||||
| -- | Project Size (min) | 5.0 ac | 5.0 ac | 10.0 ac | |||||
| -- | Amenity Space (min) | 20% | 10% | 15% | |||||
| Strategic Amenity Space (min) | 30% of required AS | 30% of required AS | 50% of required AS | ||||||
| Lot Standards | |||||||||
| A | Lot Depth (min) | 70' | 70' | -- | |||||
| B | Lot Width (min) | 19' [2] | 16' | -- | |||||
| C | Road Frontage | [3] | [3] | -- | |||||
| Building Standards | |||||||||
| Townhouse Building Placement (Principal and Accessory) [4] | |||||||||
| D | Front Setback (min) | 20' [5] | 10' | -- | |||||
| E | Side Setback for end unit (min) | 10' | 10' | -- | |||||
| F | Corner Side Setback (min) - Principal - Accessory |
15' 5' |
10' 5' | -- | |||||
| G | Rear Setback (min) - Principal - Accessory |
20' 5' |
20' [6] 5' | -- | |||||
| Multifamily Building Placement (Principal and Accessory)/Required Perimeter Landscaping | |||||||||
| H | Project Property Line Setback (min) | -- | -- | 30'/C | |||||
| I | Road Setback (min) - Arterial - Collector/All other public roads | -- | -- |
50'/C 25'/C | |||||
| J | Internal Roads and Private Pavement/Parking Spaces (min) | -- | -- |
15' | |||||
| Building Height | |||||||||
| K | Height (max) |
65' |
65' |
65' | |||||
| Access and Parking/Required Perimeter Landscaping | |||||||||
| L | Parking Location |
|
| Common Lot | |||||
| M | Parking pad length, exclusive of sidewalks (min) | 20' | -- | -- | |||||
| N | Parking Lot Setback (min) - Arterial - Collector - All other roads - Lots with dwellings/exterior property lines | See Sec. 19.2-35
15' 10' [9] |
See Sec. 19.2-35
15' 10' [9]
| 50'/C 25'/C [8] 25'/C 25'/C | |||||
| -- | Number of Access Points - 50 units or fewer - 51 or more units | See Sec. 17.1-84 | See Sec. 17.1-84 |
1 2 | |||||
| Utilities | |||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | ||||||
| Building Design | |||||||||
| O | Total garage door width as a percent of total building row length (max) | 60% | -- | -- | |||||
Notes:
| |||||||||
| Figure 19.2-12.1, TR Illustrated Renderings |
|---|
| Base - Front Loaded Suburban Townhouse |
![]() |
![]() |
![]() |
| Base - Rear Loaded/Common Parking Suburban Townhouse |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-12.1, TR Illustrated Renderings |
|---|
| Base - Front Loaded Suburban Townhouse |
![]() |
![]() |
![]() |
| Base - Rear Loaded/Common Parking Suburban Townhouse |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-12.1, TR Illustrated Renderings |
|---|
| Base - Front Loaded Suburban Townhouse |
![]() |
![]() |
![]() |
| Base - Rear Loaded/Common Parking Suburban Townhouse |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-12.1, TR Illustrated Renderings |
|---|
| Base - Front Loaded Suburban Townhouse |
![]() |
![]() |
![]() |
| Base - Rear Loaded/Common Parking Suburban Townhouse |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Provisions Related to the TR District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Amenity Space | Sec. 19.2-34 |
| Dimensional Standards | Sec. 19.2-37 |
| Landscaping and Screening | Sec. 19.2-41 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
Purpose. The Urban Residential (UR) District provides for single-family attached, multi-family, and vertically integrated mixed-use buildings and developments. The district is intended for areas within or adjacent to mixed-use centers to serve as a higher-density residential transition from suburban and semi-urban neighborhoods. Given its urban transition character and higher densities, more formal amenity spaces are set aside for small lawns, streetscapes, greens, plazas, and resident gathering areas. Amenities should be linked together with abutting developments to create a system of interconnected public spaces. The role of the UR District is to provide a variety of living types and spaces in proximity to, and in support of, mixed-use centers. Areas zoned UR require connection to the public water and wastewater systems and should be located near major transportation corridors.
Option 2. This option provides for urban-style mixed-use buildings in a walkable setting. Parking should be internal to the development.
| Table 19.2-14.1, Urban Residential (UR) Lot and Building Standards[1] | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| ' = feet | |||||||||
| Development | Base | Option 1 [2] | Option 2 [3] | ||||||
| Key | Neighborhood Type | Urban Townhouse | Multi-Family/ Condominium | Vertical Mixed-Use | |||||
| -- | Amenity Space (min) | 10% | 10% | 10% | |||||
-- | Strategic Amenity Space (min) | 30% of required AS | 50% of required AS | 75% of required AS | |||||
| -- | Road Frontage | [4] | [4] | [4] | |||||
| Building Standards | |||||||||
| Townhouse Building Placement (Principal and Accessory) | |||||||||
| A | Front Setback (min) | 10' | -- | -- | |||||
| B | Side Setback for end unit (min) | 5' | -- | -- | |||||
| C | Corner Side Setback (min) | 10' | -- | -- | |||||
| D | Rear Setback (min) - Principal - Accessory |
20' [5] 5' |
-- -- |
-- -- | |||||
| Multi-family Building Placement (Principal and Accessory)/Required Perimeter Landscaping | |||||||||
| E | Frontage Buildout (min) | -- | 60% | 60% | |||||
| F | Project Property Line Setback (min) | -- | 10' [6] | 10' [6] | |||||
| G | Road Setback (min) - Collector or Arterial - All other public roads |
-- -- |
20'/A 10'/A |
20'/A 10'/A | |||||
| H | Interior Private Pavement (min) | -- | 5' | 5' | |||||
| Building Height | |||||||||
| I | Height (max) [7] | 75' | 90' | 105' | |||||
| Access and Parking [8] | |||||||||
| J | Parking Location |
|
|
| |||||
| K | Parking Lot Setback/Required Perimeter Landscaping [9] | 5' | Same as principal building placement | Same as principal building placement | |||||
| -- | Number of Access Points - 50 units or Fewer - 51 or more |
See Sec. 17.1-84 |
See Sec. 17.1-84 |
1 2 | |||||
| Utilities | |||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | Required | |||||
Notes:
| |||||||||
| Table 19.2-14.1, Urban Residential (UR) Lot and Building Standards[1] | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| ' = feet | |||||||||
| Development | Base | Option 1 [2] | Option 2 [3] | ||||||
| Key | Neighborhood Type | Urban Townhouse | Multi-Family/ Condominium | Vertical Mixed-Use | |||||
| -- | Amenity Space (min) | 10% | 10% | 10% | |||||
-- | Strategic Amenity Space (min) | 30% of required AS | 50% of required AS | 75% of required AS | |||||
| -- | Road Frontage | [4] | [4] | [4] | |||||
| Building Standards | |||||||||
| Townhouse Building Placement (Principal and Accessory) | |||||||||
| A | Front Setback (min) | 10' | -- | -- | |||||
| B | Side Setback for end unit (min) | 5' | -- | -- | |||||
| C | Corner Side Setback (min) | 10' | -- | -- | |||||
| D | Rear Setback (min) - Principal - Accessory |
20' [5] 5' |
-- -- |
-- -- | |||||
| Multi-family Building Placement (Principal and Accessory)/Required Perimeter Landscaping | |||||||||
| E | Frontage Buildout (min) | -- | 60% | 60% | |||||
| F | Project Property Line Setback (min) | -- | 10' [6] | 10' [6] | |||||
| G | Road Setback (min) - Collector or Arterial - All other public roads |
-- -- |
20'/A 10'/A |
20'/A 10'/A | |||||
| H | Interior Private Pavement (min) | -- | 5' | 5' | |||||
| Building Height | |||||||||
| I | Height (max) [7] | 75' | 90' | 105' | |||||
| Access and Parking [8] | |||||||||
| J | Parking Location |
|
|
| |||||
| K | Parking Lot Setback/Required Perimeter Landscaping [9] | 5' | Same as principal building placement | Same as principal building placement | |||||
| -- | Number of Access Points - 50 units or Fewer - 51 or more |
See Sec. 17.1-84 |
See Sec. 17.1-84 |
1 2 | |||||
| Utilities | |||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | Required | |||||
Notes:
| |||||||||
| Table 19.2-14.1, Urban Residential (UR) Lot and Building Standards[1] | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| ' = feet | |||||||||
| Development | Base | Option 1 [2] | Option 2 [3] | ||||||
| Key | Neighborhood Type | Urban Townhouse | Multi-Family/ Condominium | Vertical Mixed-Use | |||||
| -- | Amenity Space (min) | 10% | 10% | 10% | |||||
-- | Strategic Amenity Space (min) | 30% of required AS | 50% of required AS | 75% of required AS | |||||
| -- | Road Frontage | [4] | [4] | [4] | |||||
| Building Standards | |||||||||
| Townhouse Building Placement (Principal and Accessory) | |||||||||
| A | Front Setback (min) | 10' | -- | -- | |||||
| B | Side Setback for end unit (min) | 5' | -- | -- | |||||
| C | Corner Side Setback (min) | 10' | -- | -- | |||||
| D | Rear Setback (min) - Principal - Accessory |
20' [5] 5' |
-- -- |
-- -- | |||||
| Multi-family Building Placement (Principal and Accessory)/Required Perimeter Landscaping | |||||||||
| E | Frontage Buildout (min) | -- | 60% | 60% | |||||
| F | Project Property Line Setback (min) | -- | 10' [6] | 10' [6] | |||||
| G | Road Setback (min) - Collector or Arterial - All other public roads |
-- -- |
20'/A 10'/A |
20'/A 10'/A | |||||
| H | Interior Private Pavement (min) | -- | 5' | 5' | |||||
| Building Height | |||||||||
| I | Height (max) [7] | 75' | 90' | 105' | |||||
| Access and Parking [8] | |||||||||
| J | Parking Location |
|
|
| |||||
| K | Parking Lot Setback/Required Perimeter Landscaping [9] | 5' | Same as principal building placement | Same as principal building placement | |||||
| -- | Number of Access Points - 50 units or Fewer - 51 or more |
See Sec. 17.1-84 |
See Sec. 17.1-84 |
1 2 | |||||
| Utilities | |||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | Required | |||||
Notes:
| |||||||||
| Table 19.2-14.1, Urban Residential (UR) Lot and Building Standards[1] | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| ' = feet | |||||||||
| Development | Base | Option 1 [2] | Option 2 [3] | ||||||
| Key | Neighborhood Type | Urban Townhouse | Multi-Family/ Condominium | Vertical Mixed-Use | |||||
| -- | Amenity Space (min) | 10% | 10% | 10% | |||||
-- | Strategic Amenity Space (min) | 30% of required AS | 50% of required AS | 75% of required AS | |||||
| -- | Road Frontage | [4] | [4] | [4] | |||||
| Building Standards | |||||||||
| Townhouse Building Placement (Principal and Accessory) | |||||||||
| A | Front Setback (min) | 10' | -- | -- | |||||
| B | Side Setback for end unit (min) | 5' | -- | -- | |||||
| C | Corner Side Setback (min) | 10' | -- | -- | |||||
| D | Rear Setback (min) - Principal - Accessory |
20' [5] 5' |
-- -- |
-- -- | |||||
| Multi-family Building Placement (Principal and Accessory)/Required Perimeter Landscaping | |||||||||
| E | Frontage Buildout (min) | -- | 60% | 60% | |||||
| F | Project Property Line Setback (min) | -- | 10' [6] | 10' [6] | |||||
| G | Road Setback (min) - Collector or Arterial - All other public roads |
-- -- |
20'/A 10'/A |
20'/A 10'/A | |||||
| H | Interior Private Pavement (min) | -- | 5' | 5' | |||||
| Building Height | |||||||||
| I | Height (max) [7] | 75' | 90' | 105' | |||||
| Access and Parking [8] | |||||||||
| J | Parking Location |
|
|
| |||||
| K | Parking Lot Setback/Required Perimeter Landscaping [9] | 5' | Same as principal building placement | Same as principal building placement | |||||
| -- | Number of Access Points - 50 units or Fewer - 51 or more |
See Sec. 17.1-84 |
See Sec. 17.1-84 |
1 2 | |||||
| Utilities | |||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | Required | |||||
Notes:
| |||||||||
| Figure 19.2-14.1, Illustrated UR Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-14.1, Illustrated UR Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-14.1, Illustrated UR Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-14.1, Illustrated UR Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Provisions Related to the UR District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Amenity Space | Sec. 19.2-34 |
| Building Design | Sec. 19.2-36 |
| Dimensional Standards | Sec. 19.2-37 |
| Landscaping and Screening | Sec. 19.2-41 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
Purpose. The Alternative Residential (AR) District provides for a variety of different types and arrangements of housing that may be constructed or manufactured on- or off-site and which may be placed on individual lots or a common lot. This district may accommodate manufactured or tiny home subdivisions, as well as innovative and emerging residential housing concepts.
| Table 19.2-15.1, Alternative Residential (AR) Lot and Building Standards | |||||||
|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | |||||||
| Development | Base | Option 1 | |||||
| Key | Neighborhood Type | Subdivision (Fee Simple) [1][2] | Common Lot | ||||
| -- | Amenity Space (min) | 10% | 10% | ||||
| -- | Strategic Amenity Space (min) | 0.01 ac/du | 0.01 ac/du | ||||
| -- | Road Frontage (min) | [3] | -- | ||||
| -- | Project Size (min) | 3.0 ac | 3.0 ac | ||||
| Lot Standards | |||||||
| A | Lot Area (min) | 1,500 sf. | -- | ||||
| B | Lot Width (min) | 25' | -- | ||||
| Building Standards | |||||||
| Building Placement - Subdivision (Principal and Accessory) | |||||||
| C | Front Setback (min) | 20' [4] | -- | ||||
| D | Side Setback (min) | 5' | -- | ||||
| E | Corner Side Setback (min) | 15' | -- | ||||
| F | Rear Setback (min) | 5' | -- | ||||
| Building Placement - Common Lot (Principal and Accessory)/Required Perimeter Landscaping | |||||||
| G | Road Setback (min) - Collector or Arterial - All other public roads | -- |
50'/C 25'/C | ||||
| H | Property Line Setback (min) | -- | 25'/B | ||||
| I | Internal private pavement setback (min) | -- | 5' | ||||
| Building Height and Coverage | |||||||
| J | Height (max) | 45' | 45' | ||||
| K | Building Coverage (max) | 70% | -- | ||||
| Access and Parking | |||||||
| L | Parking Location |
|
| ||||
| M | Parking Lot Setback from road (min) | Same as principal building | Same as principal buildings | ||||
| -- | Number of Access Points - Fewer than 50 units - 50 or more |
1 2 |
1 2 | ||||
| Utilities | |||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | ||||
Notes:
| |||||||
| Table 19.2-15.1, Alternative Residential (AR) Lot and Building Standards | |||||||
|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | |||||||
| Development | Base | Option 1 | |||||
| Key | Neighborhood Type | Subdivision (Fee Simple) [1][2] | Common Lot | ||||
| -- | Amenity Space (min) | 10% | 10% | ||||
| -- | Strategic Amenity Space (min) | 0.01 ac/du | 0.01 ac/du | ||||
| -- | Road Frontage (min) | [3] | -- | ||||
| -- | Project Size (min) | 3.0 ac | 3.0 ac | ||||
| Lot Standards | |||||||
| A | Lot Area (min) | 1,500 sf. | -- | ||||
| B | Lot Width (min) | 25' | -- | ||||
| Building Standards | |||||||
| Building Placement - Subdivision (Principal and Accessory) | |||||||
| C | Front Setback (min) | 20' [4] | -- | ||||
| D | Side Setback (min) | 5' | -- | ||||
| E | Corner Side Setback (min) | 15' | -- | ||||
| F | Rear Setback (min) | 5' | -- | ||||
| Building Placement - Common Lot (Principal and Accessory)/Required Perimeter Landscaping | |||||||
| G | Road Setback (min) - Collector or Arterial - All other public roads | -- |
50'/C 25'/C | ||||
| H | Property Line Setback (min) | -- | 25'/B | ||||
| I | Internal private pavement setback (min) | -- | 5' | ||||
| Building Height and Coverage | |||||||
| J | Height (max) | 45' | 45' | ||||
| K | Building Coverage (max) | 70% | -- | ||||
| Access and Parking | |||||||
| L | Parking Location |
|
| ||||
| M | Parking Lot Setback from road (min) | Same as principal building | Same as principal buildings | ||||
| -- | Number of Access Points - Fewer than 50 units - 50 or more |
1 2 |
1 2 | ||||
| Utilities | |||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | ||||
Notes:
| |||||||
| Table 19.2-15.1, Alternative Residential (AR) Lot and Building Standards | |||||||
|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | |||||||
| Development | Base | Option 1 | |||||
| Key | Neighborhood Type | Subdivision (Fee Simple) [1][2] | Common Lot | ||||
| -- | Amenity Space (min) | 10% | 10% | ||||
| -- | Strategic Amenity Space (min) | 0.01 ac/du | 0.01 ac/du | ||||
| -- | Road Frontage (min) | [3] | -- | ||||
| -- | Project Size (min) | 3.0 ac | 3.0 ac | ||||
| Lot Standards | |||||||
| A | Lot Area (min) | 1,500 sf. | -- | ||||
| B | Lot Width (min) | 25' | -- | ||||
| Building Standards | |||||||
| Building Placement - Subdivision (Principal and Accessory) | |||||||
| C | Front Setback (min) | 20' [4] | -- | ||||
| D | Side Setback (min) | 5' | -- | ||||
| E | Corner Side Setback (min) | 15' | -- | ||||
| F | Rear Setback (min) | 5' | -- | ||||
| Building Placement - Common Lot (Principal and Accessory)/Required Perimeter Landscaping | |||||||
| G | Road Setback (min) - Collector or Arterial - All other public roads | -- |
50'/C 25'/C | ||||
| H | Property Line Setback (min) | -- | 25'/B | ||||
| I | Internal private pavement setback (min) | -- | 5' | ||||
| Building Height and Coverage | |||||||
| J | Height (max) | 45' | 45' | ||||
| K | Building Coverage (max) | 70% | -- | ||||
| Access and Parking | |||||||
| L | Parking Location |
|
| ||||
| M | Parking Lot Setback from road (min) | Same as principal building | Same as principal buildings | ||||
| -- | Number of Access Points - Fewer than 50 units - 50 or more |
1 2 |
1 2 | ||||
| Utilities | |||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | ||||
Notes:
| |||||||
| Table 19.2-15.1, Alternative Residential (AR) Lot and Building Standards | |||||||
|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | |||||||
| Development | Base | Option 1 | |||||
| Key | Neighborhood Type | Subdivision (Fee Simple) [1][2] | Common Lot | ||||
| -- | Amenity Space (min) | 10% | 10% | ||||
| -- | Strategic Amenity Space (min) | 0.01 ac/du | 0.01 ac/du | ||||
| -- | Road Frontage (min) | [3] | -- | ||||
| -- | Project Size (min) | 3.0 ac | 3.0 ac | ||||
| Lot Standards | |||||||
| A | Lot Area (min) | 1,500 sf. | -- | ||||
| B | Lot Width (min) | 25' | -- | ||||
| Building Standards | |||||||
| Building Placement - Subdivision (Principal and Accessory) | |||||||
| C | Front Setback (min) | 20' [4] | -- | ||||
| D | Side Setback (min) | 5' | -- | ||||
| E | Corner Side Setback (min) | 15' | -- | ||||
| F | Rear Setback (min) | 5' | -- | ||||
| Building Placement - Common Lot (Principal and Accessory)/Required Perimeter Landscaping | |||||||
| G | Road Setback (min) - Collector or Arterial - All other public roads | -- |
50'/C 25'/C | ||||
| H | Property Line Setback (min) | -- | 25'/B | ||||
| I | Internal private pavement setback (min) | -- | 5' | ||||
| Building Height and Coverage | |||||||
| J | Height (max) | 45' | 45' | ||||
| K | Building Coverage (max) | 70% | -- | ||||
| Access and Parking | |||||||
| L | Parking Location |
|
| ||||
| M | Parking Lot Setback from road (min) | Same as principal building | Same as principal buildings | ||||
| -- | Number of Access Points - Fewer than 50 units - 50 or more |
1 2 |
1 2 | ||||
| Utilities | |||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | ||||
Notes:
| |||||||
| Figure 19.2-15.1, AR Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-15.1, AR Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-15.1, AR Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-15.1, AR Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Provisions Related to the AR District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Amenity Space | Sec. 19.2-34 |
| Dimensional Standards | Sec. 19.2-37 |
| Landscaping and Screening | Sec. 19.2-41 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
Purpose. The Neighborhood Business (NB) District provides for small-scale and neighborhood serving commercial, office, retail and service uses. To ensure compatibility within both rural and suburban contexts, limitations are established to manage the type and scale of uses and buildings. This district is most often located at neighborhood entrances, collector street intersections, along the frontage of streets bounding neighborhoods, and as small centers within a master planned development. In established areas along arterial corridors, this district may also be used for existing homes that warrant transition to live-work units or office conversions. This District also applies to rural intersections providing convenience uses to area residents. The nature of this district makes it appropriate as a transition between the Corridor Commercial District and Residential Districts.
| Table 19.2-16, Neighborhood Business (NB) Lot and Building Standards | |||||
|---|---|---|---|---|---|
| sf. = square feet ' = feet | |||||
| Development | Base | Option 1 | |||
| Key | Category | Neighborhood Commercial | Rural | ||
| -- | Gross Floor Area per building (max) | 20,000 sf. [1] | 10,000 sf. | ||
| -- | Amenity Space (min) | 5% | -- | ||
| Building and Parking Standards | |||||
| Building Setbacks / Required Perimeter Landscaping | |||||
| A | Road Setback (min) - Arterial Road - Collector/Local Road - Internal Road |
30'/C 25'/C 10'/A |
50'/B 25'/B 10'/A | ||
| B | Other Property Lines Setback (min) [2] | 10'/B | 25'/B | ||
| Building Height | |||||
| C | Height (max) | 45' | 45' | ||
| Parking Setback/Required Perimeter Landscaping | |||||
| D | Parking Lot Setback (min) - Arterial Road - All Other Roads/Property Lines |
50'/A 25'/C |
50'/A 25'/C | ||
| Utilities | |||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Water Required; Wastewater Not Required | ||
| Other Limitations | |||||
| -- | Hours of Operation | 6:00 AM to 9:00 PM | 6:00 AM to 9:00 PM | ||
Notes:
| |||||
| Table 19.2-16, Neighborhood Business (NB) Lot and Building Standards | |||||
|---|---|---|---|---|---|
| sf. = square feet ' = feet | |||||
| Development | Base | Option 1 | |||
| Key | Category | Neighborhood Commercial | Rural | ||
| -- | Gross Floor Area per building (max) | 20,000 sf. [1] | 10,000 sf. | ||
| -- | Amenity Space (min) | 5% | -- | ||
| Building and Parking Standards | |||||
| Building Setbacks / Required Perimeter Landscaping | |||||
| A | Road Setback (min) - Arterial Road - Collector/Local Road - Internal Road |
30'/C 25'/C 10'/A |
50'/B 25'/B 10'/A | ||
| B | Other Property Lines Setback (min) [2] | 10'/B | 25'/B | ||
| Building Height | |||||
| C | Height (max) | 45' | 45' | ||
| Parking Setback/Required Perimeter Landscaping | |||||
| D | Parking Lot Setback (min) - Arterial Road - All Other Roads/Property Lines |
50'/A 25'/C |
50'/A 25'/C | ||
| Utilities | |||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Water Required; Wastewater Not Required | ||
| Other Limitations | |||||
| -- | Hours of Operation | 6:00 AM to 9:00 PM | 6:00 AM to 9:00 PM | ||
Notes:
| |||||
| Table 19.2-16, Neighborhood Business (NB) Lot and Building Standards | |||||
|---|---|---|---|---|---|
| sf. = square feet ' = feet | |||||
| Development | Base | Option 1 | |||
| Key | Category | Neighborhood Commercial | Rural | ||
| -- | Gross Floor Area per building (max) | 20,000 sf. [1] | 10,000 sf. | ||
| -- | Amenity Space (min) | 5% | -- | ||
| Building and Parking Standards | |||||
| Building Setbacks / Required Perimeter Landscaping | |||||
| A | Road Setback (min) - Arterial Road - Collector/Local Road - Internal Road |
30'/C 25'/C 10'/A |
50'/B 25'/B 10'/A | ||
| B | Other Property Lines Setback (min) [2] | 10'/B | 25'/B | ||
| Building Height | |||||
| C | Height (max) | 45' | 45' | ||
| Parking Setback/Required Perimeter Landscaping | |||||
| D | Parking Lot Setback (min) - Arterial Road - All Other Roads/Property Lines |
50'/A 25'/C |
50'/A 25'/C | ||
| Utilities | |||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Water Required; Wastewater Not Required | ||
| Other Limitations | |||||
| -- | Hours of Operation | 6:00 AM to 9:00 PM | 6:00 AM to 9:00 PM | ||
Notes:
| |||||
| Table 19.2-16, Neighborhood Business (NB) Lot and Building Standards | |||||
|---|---|---|---|---|---|
| sf. = square feet ' = feet | |||||
| Development | Base | Option 1 | |||
| Key | Category | Neighborhood Commercial | Rural | ||
| -- | Gross Floor Area per building (max) | 20,000 sf. [1] | 10,000 sf. | ||
| -- | Amenity Space (min) | 5% | -- | ||
| Building and Parking Standards | |||||
| Building Setbacks / Required Perimeter Landscaping | |||||
| A | Road Setback (min) - Arterial Road - Collector/Local Road - Internal Road |
30'/C 25'/C 10'/A |
50'/B 25'/B 10'/A | ||
| B | Other Property Lines Setback (min) [2] | 10'/B | 25'/B | ||
| Building Height | |||||
| C | Height (max) | 45' | 45' | ||
| Parking Setback/Required Perimeter Landscaping | |||||
| D | Parking Lot Setback (min) - Arterial Road - All Other Roads/Property Lines |
50'/A 25'/C |
50'/A 25'/C | ||
| Utilities | |||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Water Required; Wastewater Not Required | ||
| Other Limitations | |||||
| -- | Hours of Operation | 6:00 AM to 9:00 PM | 6:00 AM to 9:00 PM | ||
Notes:
| |||||
| Figure 19.2-16.1, NB Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-16.1, NB Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-16.1, NB Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-16.1, NB Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Provisions Related to the NB District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Amenity Space | Sec. 19.2-34 |
| Buffers | Sec. 19.2-35 |
| Building Design | Sec. 19.2-36 |
| Landscaping and Screening | Sec. 19.2-41 |
| Exterior Lighting | Sec. 19.2-38 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
Purpose. The Corridor Commercial (CC) District provides for a variety of commercial, office, retail, and service uses in both freestanding and multi-tenant buildings and centers. Sites within this district may vary in size and scale depending upon the types and characteristics of land use and their locations along corridor frontages (abutting neighborhoods), near intersections or when combined with office uses.
Due to the variety of land uses, larger footprints of buildings, and the expanse of parking, site design is of great importance to ensure sites are functional and efficient in moving both vehicles and pedestrians. Attractive building design is important to realize quality, sustainable developments of an enduring value. Buffering, landscaping, and screening are essential to transition uses and districts of different intensities, to enhance visual character, and for their ecological benefits.
| Table 19.2-17.1, Corridor Commercial (CC) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ' = feet | ||||||||
| Development | Base | Option 1 | Option 2 | |||||
| Key | Category | Freestanding Commercial | Center | CC with Residential [1] | ||||
| -- | Amenity Space (min) | -- | 7.5% | 10% | ||||
| Strategic Amenity Space (min) | -- | 30% of required AS | 50% of required AS | |||||
| Building Standards | ||||||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||||||
| A | Front/Road Setback (min) - Arterial - Collector/Other Roads - Internal Roads |
50'/C 25'/C 10'/A |
50'/C 25'/C 10'/A |
50'/C 25'/C 10'/A | ||||
| B | Other Property Lines Setback (min) | 10'/B | 10'/B | 10'/B | ||||
| Building Height [2] | ||||||||
| C | Height (max) | 65' | 65' | 65' | ||||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | Required | ||||
Notes:
| ||||||||
| Table 19.2-17.1, Corridor Commercial (CC) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ' = feet | ||||||||
| Development | Base | Option 1 | Option 2 | |||||
| Key | Category | Freestanding Commercial | Center | CC with Residential [1] | ||||
| -- | Amenity Space (min) | -- | 7.5% | 10% | ||||
| Strategic Amenity Space (min) | -- | 30% of required AS | 50% of required AS | |||||
| Building Standards | ||||||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||||||
| A | Front/Road Setback (min) - Arterial - Collector/Other Roads - Internal Roads |
50'/C 25'/C 10'/A |
50'/C 25'/C 10'/A |
50'/C 25'/C 10'/A | ||||
| B | Other Property Lines Setback (min) | 10'/B | 10'/B | 10'/B | ||||
| Building Height [2] | ||||||||
| C | Height (max) | 65' | 65' | 65' | ||||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | Required | ||||
Notes:
| ||||||||
| Table 19.2-17.1, Corridor Commercial (CC) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ' = feet | ||||||||
| Development | Base | Option 1 | Option 2 | |||||
| Key | Category | Freestanding Commercial | Center | CC with Residential [1] | ||||
| -- | Amenity Space (min) | -- | 7.5% | 10% | ||||
| Strategic Amenity Space (min) | -- | 30% of required AS | 50% of required AS | |||||
| Building Standards | ||||||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||||||
| A | Front/Road Setback (min) - Arterial - Collector/Other Roads - Internal Roads |
50'/C 25'/C 10'/A |
50'/C 25'/C 10'/A |
50'/C 25'/C 10'/A | ||||
| B | Other Property Lines Setback (min) | 10'/B | 10'/B | 10'/B | ||||
| Building Height [2] | ||||||||
| C | Height (max) | 65' | 65' | 65' | ||||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | Required | ||||
Notes:
| ||||||||
| Table 19.2-17.1, Corridor Commercial (CC) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ' = feet | ||||||||
| Development | Base | Option 1 | Option 2 | |||||
| Key | Category | Freestanding Commercial | Center | CC with Residential [1] | ||||
| -- | Amenity Space (min) | -- | 7.5% | 10% | ||||
| Strategic Amenity Space (min) | -- | 30% of required AS | 50% of required AS | |||||
| Building Standards | ||||||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||||||
| A | Front/Road Setback (min) - Arterial - Collector/Other Roads - Internal Roads |
50'/C 25'/C 10'/A |
50'/C 25'/C 10'/A |
50'/C 25'/C 10'/A | ||||
| B | Other Property Lines Setback (min) | 10'/B | 10'/B | 10'/B | ||||
| Building Height [2] | ||||||||
| C | Height (max) | 65' | 65' | 65' | ||||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | Required | ||||
Notes:
| ||||||||
| Figure 19.2-17.1, CC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-17.1, CC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-17.1, CC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-17.1, CC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Provisions Related to the CC District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Amenity Space | Sec. 19.2-34 |
| Buffers | Sec. 19.2-35 |
| Building Design | Sec. 19.2-36 |
| Buffers | Sec. 19.2-35 |
| Exterior Lighting | Sec. 19.2-38 |
| Landscaping and Screening | Sec. 19.2-41 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
Purpose. The Mixed-Use Center (MU) District provides for the development of mixed-use centers at different scales and in different contexts. Mixed-use may include single-family attached and multifamily residential, together with commercial retail, service, entertainment, and office uses that may be designed in horizontal or vertical formats. Development in the MU District that includes residential uses should incorporate a variety of housing options and pedestrian-oriented design to ensure connectivity between uses for a cohesive development. This development type and form may serve as a node for several neighborhoods, as an urban activity center, or a regional destination located off of key highway interchanges. This district may also facilitate the redevelopment of underutilized shopping centers by redesigning the site to integrate other use and building types.
| Table 19.2-18.1, Mixed-Use Center (MU) Lot and Building Standards [1] | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| ' = feet | |||||||||
| Development | Base | Option 1 | Option 2 | ||||||
| Key | Category | Neighborhood | Community | Regional | |||||
Gross Floor Area Ratio [2] - Commercial (min)/Residential (max) | 15%/85% | 15%/85% | 15%/85% | ||||||
| Amenity Space (min) | 10% | 10% | 10% | ||||||
| Strategic Amenity Space (min) | 30% of required AS | 50% of required AS | 75% of required AS | ||||||
| Building Standards [3][4] | |||||||||
| Building Placement/Required Perimeter Landscaping | |||||||||
| A | Frontage Buildout (min) | 50% | 60% | 70% | |||||
| B | Road Setback (min) | 10'/A | 10'/A | 10'/A | |||||
| C | Other Property Lines Setback (min) | 10'/A | 10'/A | 10'/A | |||||
| Building Height | |||||||||
| D | Height (min/max) | --/45' | 30'/75' [5] | 30'/150' | |||||
| Parking | |||||||||
| E | Parking Location |
|
|
| |||||
| F | Parking Lot Setback (min)/Required Perimeter Landscaping [3][6][7] | 10'/A | 10'/A | 10'/A | |||||
| Utilities | |||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | Required | |||||
Notes:
| |||||||||
| Table 19.2-18.1, Mixed-Use Center (MU) Lot and Building Standards [1] | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| ' = feet | |||||||||
| Development | Base | Option 1 | Option 2 | ||||||
| Key | Category | Neighborhood | Community | Regional | |||||
Gross Floor Area Ratio [2] - Commercial (min)/Residential (max) | 15%/85% | 15%/85% | 15%/85% | ||||||
| Amenity Space (min) | 10% | 10% | 10% | ||||||
| Strategic Amenity Space (min) | 30% of required AS | 50% of required AS | 75% of required AS | ||||||
| Building Standards [3][4] | |||||||||
| Building Placement/Required Perimeter Landscaping | |||||||||
| A | Frontage Buildout (min) | 50% | 60% | 70% | |||||
| B | Road Setback (min) | 10'/A | 10'/A | 10'/A | |||||
| C | Other Property Lines Setback (min) | 10'/A | 10'/A | 10'/A | |||||
| Building Height | |||||||||
| D | Height (min/max) | --/45' | 30'/75' [5] | 30'/150' | |||||
| Parking | |||||||||
| E | Parking Location |
|
|
| |||||
| F | Parking Lot Setback (min)/Required Perimeter Landscaping [3][6][7] | 10'/A | 10'/A | 10'/A | |||||
| Utilities | |||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | Required | |||||
Notes:
| |||||||||
| Table 19.2-18.1, Mixed-Use Center (MU) Lot and Building Standards [1] | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| ' = feet | |||||||||
| Development | Base | Option 1 | Option 2 | ||||||
| Key | Category | Neighborhood | Community | Regional | |||||
Gross Floor Area Ratio [2] - Commercial (min)/Residential (max) | 15%/85% | 15%/85% | 15%/85% | ||||||
| Amenity Space (min) | 10% | 10% | 10% | ||||||
| Strategic Amenity Space (min) | 30% of required AS | 50% of required AS | 75% of required AS | ||||||
| Building Standards [3][4] | |||||||||
| Building Placement/Required Perimeter Landscaping | |||||||||
| A | Frontage Buildout (min) | 50% | 60% | 70% | |||||
| B | Road Setback (min) | 10'/A | 10'/A | 10'/A | |||||
| C | Other Property Lines Setback (min) | 10'/A | 10'/A | 10'/A | |||||
| Building Height | |||||||||
| D | Height (min/max) | --/45' | 30'/75' [5] | 30'/150' | |||||
| Parking | |||||||||
| E | Parking Location |
|
|
| |||||
| F | Parking Lot Setback (min)/Required Perimeter Landscaping [3][6][7] | 10'/A | 10'/A | 10'/A | |||||
| Utilities | |||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | Required | |||||
Notes:
| |||||||||
| Table 19.2-18.1, Mixed-Use Center (MU) Lot and Building Standards [1] | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| ' = feet | |||||||||
| Development | Base | Option 1 | Option 2 | ||||||
| Key | Category | Neighborhood | Community | Regional | |||||
Gross Floor Area Ratio [2] - Commercial (min)/Residential (max) | 15%/85% | 15%/85% | 15%/85% | ||||||
| Amenity Space (min) | 10% | 10% | 10% | ||||||
| Strategic Amenity Space (min) | 30% of required AS | 50% of required AS | 75% of required AS | ||||||
| Building Standards [3][4] | |||||||||
| Building Placement/Required Perimeter Landscaping | |||||||||
| A | Frontage Buildout (min) | 50% | 60% | 70% | |||||
| B | Road Setback (min) | 10'/A | 10'/A | 10'/A | |||||
| C | Other Property Lines Setback (min) | 10'/A | 10'/A | 10'/A | |||||
| Building Height | |||||||||
| D | Height (min/max) | --/45' | 30'/75' [5] | 30'/150' | |||||
| Parking | |||||||||
| E | Parking Location |
|
|
| |||||
| F | Parking Lot Setback (min)/Required Perimeter Landscaping [3][6][7] | 10'/A | 10'/A | 10'/A | |||||
| Utilities | |||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | Required | |||||
Notes:
| |||||||||
| Figure 19.2-18.1, MU Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-18.1, MU Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-18.1, MU Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-18.1, MU Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Provisions Related to the MU District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Amenity Space | Sec. 19.2-34 |
| Buffers | Sec. 19.2-35 |
| Building Design | Sec. 19.2-36 |
| Landscaping and Screening | Sec. 19.2-41 |
| Exterior Lighting | Sec. 19.2-38 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
Purpose. The Employment Center (EC) District provides for a freestanding employment use or a larger-scale business park. The EC District is oriented toward professional and administrative offices, research and technology, and light industrial uses that operate within the confines of their building and do not have outdoor display or storage. The uses within an employment center may range from corporate headquarters to multi-tenant office buildings, educational and institutional facilities, medical uses, overnight accommodations, finished goods production and assembly, and other related uses. These uses, by virtue of the use types and design standards, should be mutually harmonious with other businesses, as well as with residential, commercial, and other uses permitted in nearby districts. Development within the district emphasizes architectural, aesthetic, and environmental considerations.
Applicability. The EC District should be used to implement the areas shown in the Comprehensive Plan as Office/Light Production and Assembly. Properties within this district are located where negative impacts on the surrounding transportation system and environmental resources are minimized, the uses are compatible with surrounding development, and the intensity of the project is consistent with the Comprehensive Plan. Displayed in Figure 19.2-19.1, EC Illustrated Renderings, are graphic depictions of the lot and building standards. The standards in Table 19.2-19.1, EC Lot and Building Standards, reflect a base pattern and one option:
| Table 19.2-19.1, Employment Center (EC) Lot and Building Standards | ||||
|---|---|---|---|---|
' = feet | ||||
| Development | Base | Option 1 | ||
| Key | Category | Freestanding | Business Park | |
| -- | Amenity Space (min) | -- | 5% | |
| Strategic Amenity Space (min) | -- | 15% of required AS | ||
| Building Standards | ||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||
| A | Road Setback (min) -Arterial Road -Collector/Local Road -Internal Road |
50'/C 25'/B -- |
50'/C 25'/B 10'/A | |
| B | Other Property Lines Setback (min) | 10'/B | 10'/B | |
| Building Height | ||||
| C | Height (max) [1] | 60' [2] | 150' | |
| Parking | ||||
| D | Parking Location |
|
| |
| Utilities | ||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | |
Notes:
| ||||
| Table 19.2-19.1, Employment Center (EC) Lot and Building Standards | ||||
|---|---|---|---|---|
' = feet | ||||
| Development | Base | Option 1 | ||
| Key | Category | Freestanding | Business Park | |
| -- | Amenity Space (min) | -- | 5% | |
| Strategic Amenity Space (min) | -- | 15% of required AS | ||
| Building Standards | ||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||
| A | Road Setback (min) -Arterial Road -Collector/Local Road -Internal Road |
50'/C 25'/B -- |
50'/C 25'/B 10'/A | |
| B | Other Property Lines Setback (min) | 10'/B | 10'/B | |
| Building Height | ||||
| C | Height (max) [1] | 60' [2] | 150' | |
| Parking | ||||
| D | Parking Location |
|
| |
| Utilities | ||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | |
Notes:
| ||||
| Table 19.2-19.1, Employment Center (EC) Lot and Building Standards | ||||
|---|---|---|---|---|
' = feet | ||||
| Development | Base | Option 1 | ||
| Key | Category | Freestanding | Business Park | |
| -- | Amenity Space (min) | -- | 5% | |
| Strategic Amenity Space (min) | -- | 15% of required AS | ||
| Building Standards | ||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||
| A | Road Setback (min) -Arterial Road -Collector/Local Road -Internal Road |
50'/C 25'/B -- |
50'/C 25'/B 10'/A | |
| B | Other Property Lines Setback (min) | 10'/B | 10'/B | |
| Building Height | ||||
| C | Height (max) [1] | 60' [2] | 150' | |
| Parking | ||||
| D | Parking Location |
|
| |
| Utilities | ||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | |
Notes:
| ||||
| Table 19.2-19.1, Employment Center (EC) Lot and Building Standards | ||||
|---|---|---|---|---|
' = feet | ||||
| Development | Base | Option 1 | ||
| Key | Category | Freestanding | Business Park | |
| -- | Amenity Space (min) | -- | 5% | |
| Strategic Amenity Space (min) | -- | 15% of required AS | ||
| Building Standards | ||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||
| A | Road Setback (min) -Arterial Road -Collector/Local Road -Internal Road |
50'/C 25'/B -- |
50'/C 25'/B 10'/A | |
| B | Other Property Lines Setback (min) | 10'/B | 10'/B | |
| Building Height | ||||
| C | Height (max) [1] | 60' [2] | 150' | |
| Parking | ||||
| D | Parking Location |
|
| |
| Utilities | ||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | |
Notes:
| ||||
| Figure 19.2-19.1, EC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-19.1, EC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-19.1, EC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-19.1, EC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Provisions Related to the EC District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Amenity Space | Sec. 19.2-34 |
| Buffers | Sec. 19.2-35 |
| Building Design | Sec. 19.2-36 |
| Landscaping and Screening | Sec. 19.2-41 |
| Exterior Lighting | Sec. 19.2-38 |
| Parkin | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
Purpose. The Employment General (EG) District provides for larger and more intense land uses that may be located on individual parcels or on a lot within an employment park. The uses within this district may involve medium to heavy manufacturing, special trade contractors, equipment sales and service, welding and machine fabrication, materials handling, and ancillary storage and transportation uses. By the nature and scale of these operations, there are expected concerns associated with peak hour employee traffic and potential impacts of light, noise, dust, vibration, odor, outside storage, or business activities. The heavy commercial and industrial activities in this district must be abated by site and building design and environmental performance standards to mitigate the impacts.
| Table 19.2-20, Employment General (EG) Lot, Building, and Transition Standards | ||||
|---|---|---|---|---|
| ' = feet | ||||
| Development | Base | Option 1 | ||
| Key | Category | Freestanding | Employment Park | |
| -- | Amenity Space (min) | -- | -- | |
| Building Standards | ||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||
| A | Road Setback (min) - Arterial Road - Collector/Local Road - Internal Road |
75'/C 60'/C -- |
75'/C 60'/C 25'/C | |
| B | Other Property Lines Setback (min) | 20'/B | 20'/B [1] | |
| Building Height | ||||
| C | Height (max) [2] | 150' | 150' | |
| Parking | ||||
| D | Parking Location |
|
| |
| Utilities | ||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | |
Notes: [1] Setbacks may be reduced to zero feet where adjacent property is zoned EG. [2] Within 200 feet of a developed residential neighborhood, the height shall not exceed 60'. Maximum height can equal the height of a residential structure within 100' of the common boundary if greater than 60'. | ||||
| Table 19.2-20, Employment General (EG) Lot, Building, and Transition Standards | ||||
|---|---|---|---|---|
| ' = feet | ||||
| Development | Base | Option 1 | ||
| Key | Category | Freestanding | Employment Park | |
| -- | Amenity Space (min) | -- | -- | |
| Building Standards | ||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||
| A | Road Setback (min) - Arterial Road - Collector/Local Road - Internal Road |
75'/C 60'/C -- |
75'/C 60'/C 25'/C | |
| B | Other Property Lines Setback (min) | 20'/B | 20'/B [1] | |
| Building Height | ||||
| C | Height (max) [2] | 150' | 150' | |
| Parking | ||||
| D | Parking Location |
|
| |
| Utilities | ||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | |
Notes: [1] Setbacks may be reduced to zero feet where adjacent property is zoned EG. [2] Within 200 feet of a developed residential neighborhood, the height shall not exceed 60'. Maximum height can equal the height of a residential structure within 100' of the common boundary if greater than 60'. | ||||
| Table 19.2-20, Employment General (EG) Lot, Building, and Transition Standards | ||||
|---|---|---|---|---|
| ' = feet | ||||
| Development | Base | Option 1 | ||
| Key | Category | Freestanding | Employment Park | |
| -- | Amenity Space (min) | -- | -- | |
| Building Standards | ||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||
| A | Road Setback (min) - Arterial Road - Collector/Local Road - Internal Road |
75'/C 60'/C -- |
75'/C 60'/C 25'/C | |
| B | Other Property Lines Setback (min) | 20'/B | 20'/B [1] | |
| Building Height | ||||
| C | Height (max) [2] | 150' | 150' | |
| Parking | ||||
| D | Parking Location |
|
| |
| Utilities | ||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | |
Notes: [1] Setbacks may be reduced to zero feet where adjacent property is zoned EG. [2] Within 200 feet of a developed residential neighborhood, the height shall not exceed 60'. Maximum height can equal the height of a residential structure within 100' of the common boundary if greater than 60'. | ||||
| Table 19.2-20, Employment General (EG) Lot, Building, and Transition Standards | ||||
|---|---|---|---|---|
| ' = feet | ||||
| Development | Base | Option 1 | ||
| Key | Category | Freestanding | Employment Park | |
| -- | Amenity Space (min) | -- | -- | |
| Building Standards | ||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||
| A | Road Setback (min) - Arterial Road - Collector/Local Road - Internal Road |
75'/C 60'/C -- |
75'/C 60'/C 25'/C | |
| B | Other Property Lines Setback (min) | 20'/B | 20'/B [1] | |
| Building Height | ||||
| C | Height (max) [2] | 150' | 150' | |
| Parking | ||||
| D | Parking Location |
|
| |
| Utilities | ||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | |
Notes: [1] Setbacks may be reduced to zero feet where adjacent property is zoned EG. [2] Within 200 feet of a developed residential neighborhood, the height shall not exceed 60'. Maximum height can equal the height of a residential structure within 100' of the common boundary if greater than 60'. | ||||
| Figure 19.2-20.1, EG Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-20.1, EG Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-20.1, EG Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-20.1, EG Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Provisions Related to the EG District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Amenity Space | Sec. 19.2-34 |
| Buffers | Sec. 19.2-35 |
| Building Design | Sec. 19.2-36 |
| Landscaping and Screening | Sec. 19.2-41 |
| Exterior Lighting | Sec. 19.2-38 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
Purpose. The Warehouse and Distribution (WD) District provides for development of warehouse, outdoor storage, distribution, trucking, and related uses, facilities, and operations. The amount of land, building floor area, and volume of shipping, receiving and heavy truck traffic warrants site locations in proximity to rail or water transportation and limited access highways. This district should be located away from residential uses and primary and secondary schools to avoid the common issues and impacts of these uses. This district necessitates development standards to address high volumes of truck traffic and compatibility with less intense zoning districts that share a common boundary.
| Table 19.2-21.1, Warehouse and Distribution (WD) Lot, Building, and Transition Standards | ||||
|---|---|---|---|---|
| ' = feet | ||||
| Development | Base | Option 1 | ||
| Key | Category | Freestanding | Warehouse Park | |
| -- | Amenity Space (min) | -- | -- | |
| Building Standards | ||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||
| A | Road - Arterial Road - Collector/Local Road - Internal Road |
75'/C 60'/C -- |
75'/C 75'/C 10'/A | |
| B | Other Property Lines Setback (min) | 20'/B | 20'/B | |
| Building Height | ||||
| C | Height (max) [1] | 150' | 150' | |
| Parking | ||||
| D | Parking Location |
|
| |
| Utilities | ||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | |
Notes:
| ||||
| Table 19.2-21.1, Warehouse and Distribution (WD) Lot, Building, and Transition Standards | ||||
|---|---|---|---|---|
| ' = feet | ||||
| Development | Base | Option 1 | ||
| Key | Category | Freestanding | Warehouse Park | |
| -- | Amenity Space (min) | -- | -- | |
| Building Standards | ||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||
| A | Road - Arterial Road - Collector/Local Road - Internal Road |
75'/C 60'/C -- |
75'/C 75'/C 10'/A | |
| B | Other Property Lines Setback (min) | 20'/B | 20'/B | |
| Building Height | ||||
| C | Height (max) [1] | 150' | 150' | |
| Parking | ||||
| D | Parking Location |
|
| |
| Utilities | ||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | |
Notes:
| ||||
| Table 19.2-21.1, Warehouse and Distribution (WD) Lot, Building, and Transition Standards | ||||
|---|---|---|---|---|
| ' = feet | ||||
| Development | Base | Option 1 | ||
| Key | Category | Freestanding | Warehouse Park | |
| -- | Amenity Space (min) | -- | -- | |
| Building Standards | ||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||
| A | Road - Arterial Road - Collector/Local Road - Internal Road |
75'/C 60'/C -- |
75'/C 75'/C 10'/A | |
| B | Other Property Lines Setback (min) | 20'/B | 20'/B | |
| Building Height | ||||
| C | Height (max) [1] | 150' | 150' | |
| Parking | ||||
| D | Parking Location |
|
| |
| Utilities | ||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | |
Notes:
| ||||
| Table 19.2-21.1, Warehouse and Distribution (WD) Lot, Building, and Transition Standards | ||||
|---|---|---|---|---|
| ' = feet | ||||
| Development | Base | Option 1 | ||
| Key | Category | Freestanding | Warehouse Park | |
| -- | Amenity Space (min) | -- | -- | |
| Building Standards | ||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||
| A | Road - Arterial Road - Collector/Local Road - Internal Road |
75'/C 60'/C -- |
75'/C 75'/C 10'/A | |
| B | Other Property Lines Setback (min) | 20'/B | 20'/B | |
| Building Height | ||||
| C | Height (max) [1] | 150' | 150' | |
| Parking | ||||
| D | Parking Location |
|
| |
| Utilities | ||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | |
Notes:
| ||||
| Figure 19.2-21.1, WD Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-21.1, WD Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-21.1, WD Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-21.1, WD Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Provisions Related to the WD District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Amenity Space | Sec. 19.2-34 |
| Buffers | Sec. 19.2-35 |
| Building Design | Sec. 19.2-36 |
| Landscaping and Screening | Sec. 19.2-41 |
| Exterior Lighting | Sec. 19.2-38 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
Purpose. The Village Overlay (VO) District protects the County's historic villages and other unique mixed-use areas, including Bon Air, Chester, Ettrick, Matoaca, Midlothian, and Rockwood.
| Figure 19.2-22.1, Village Overlay Map | |
|---|---|
|
| Table 19.2-22.1 Village Overlay (VO) Lot and Building Standards [1] | ||||
|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||
| Development | ||||
| Key | Category | Standard | ||
| A | Amenity Space (min) | 10% | ||
| Strategic Amenity Space (min) | 75% | |||
| Building Standards | ||||
| Building Setbacks /Required Perimeter Landscaping | ||||
| Road Type | ||||
| B | Limited Access (min) | 40'/C | ||
| C | Arterial/Other (min) | 10’/A | ||
| Interior Side Yard [2] | ||||
| D | Adjacent to Residential Districts (min) | 10’/B | ||
| E | Nonresidential use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 0' | ||
| F | Multifamily use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10'/B | ||
| Rear Yard [2] | ||||
| G | Adjacent to Residential Districts (min) | 10’/B | ||
| H | Nonresidential use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 0' | ||
| I | Multifamily use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10'/B | ||
| Parking Setbacks (feet)/Required Perimeter Landscaping | ||||
| Road Type | ||||
| J | Limited Access (min) | 40'/C | ||
| K | Arterial/Other (min) | No closer to road than building face/B [3] | ||
| Interior Side Yard and Rear Yard | ||||
| L | All developments (min) | 10’/B [3,4] | ||
| Building Height | ||||
| Generally | ||||
| M | Height (min), building fronting arterial roads | 30' | ||
| N | Height (max), generally [5] [6] | 70' | ||
| O | Height (max), within 100' of arterial road or property zoned or used for single-family detached dwellings | 45' | ||
Notes:
| ||||
| Table 19.2-22.1 Village Overlay (VO) Lot and Building Standards [1] | ||||
|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||
| Development | ||||
| Key | Category | Standard | ||
| A | Amenity Space (min) | 10% | ||
| Strategic Amenity Space (min) | 75% | |||
| Building Standards | ||||
| Building Setbacks /Required Perimeter Landscaping | ||||
| Road Type | ||||
| B | Limited Access (min) | 40'/C | ||
| C | Arterial/Other (min) | 10’/A | ||
| Interior Side Yard [2] | ||||
| D | Adjacent to Residential Districts (min) | 10’/B | ||
| E | Nonresidential use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 0' | ||
| F | Multifamily use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10'/B | ||
| Rear Yard [2] | ||||
| G | Adjacent to Residential Districts (min) | 10’/B | ||
| H | Nonresidential use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 0' | ||
| I | Multifamily use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10'/B | ||
| Parking Setbacks (feet)/Required Perimeter Landscaping | ||||
| Road Type | ||||
| J | Limited Access (min) | 40'/C | ||
| K | Arterial/Other (min) | No closer to road than building face/B [3] | ||
| Interior Side Yard and Rear Yard | ||||
| L | All developments (min) | 10’/B [3,4] | ||
| Building Height | ||||
| Generally | ||||
| M | Height (min), building fronting arterial roads | 30' | ||
| N | Height (max), generally [5] [6] | 70' | ||
| O | Height (max), within 100' of arterial road or property zoned or used for single-family detached dwellings | 45' | ||
Notes:
| ||||
| Table 19.2-22.1 Village Overlay (VO) Lot and Building Standards [1] | ||||
|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||
| Development | ||||
| Key | Category | Standard | ||
| A | Amenity Space (min) | 10% | ||
| Strategic Amenity Space (min) | 75% | |||
| Building Standards | ||||
| Building Setbacks /Required Perimeter Landscaping | ||||
| Road Type | ||||
| B | Limited Access (min) | 40'/C | ||
| C | Arterial/Other (min) | 10’/A | ||
| Interior Side Yard [2] | ||||
| D | Adjacent to Residential Districts (min) | 10’/B | ||
| E | Nonresidential use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 0' | ||
| F | Multifamily use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10'/B | ||
| Rear Yard [2] | ||||
| G | Adjacent to Residential Districts (min) | 10’/B | ||
| H | Nonresidential use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 0' | ||
| I | Multifamily use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10'/B | ||
| Parking Setbacks (feet)/Required Perimeter Landscaping | ||||
| Road Type | ||||
| J | Limited Access (min) | 40'/C | ||
| K | Arterial/Other (min) | No closer to road than building face/B [3] | ||
| Interior Side Yard and Rear Yard | ||||
| L | All developments (min) | 10’/B [3,4] | ||
| Building Height | ||||
| Generally | ||||
| M | Height (min), building fronting arterial roads | 30' | ||
| N | Height (max), generally [5] [6] | 70' | ||
| O | Height (max), within 100' of arterial road or property zoned or used for single-family detached dwellings | 45' | ||
Notes:
| ||||
| Table 19.2-22.1 Village Overlay (VO) Lot and Building Standards [1] | ||||
|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||
| Development | ||||
| Key | Category | Standard | ||
| A | Amenity Space (min) | 10% | ||
| Strategic Amenity Space (min) | 75% | |||
| Building Standards | ||||
| Building Setbacks /Required Perimeter Landscaping | ||||
| Road Type | ||||
| B | Limited Access (min) | 40'/C | ||
| C | Arterial/Other (min) | 10’/A | ||
| Interior Side Yard [2] | ||||
| D | Adjacent to Residential Districts (min) | 10’/B | ||
| E | Nonresidential use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 0' | ||
| F | Multifamily use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10'/B | ||
| Rear Yard [2] | ||||
| G | Adjacent to Residential Districts (min) | 10’/B | ||
| H | Nonresidential use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 0' | ||
| I | Multifamily use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10'/B | ||
| Parking Setbacks (feet)/Required Perimeter Landscaping | ||||
| Road Type | ||||
| J | Limited Access (min) | 40'/C | ||
| K | Arterial/Other (min) | No closer to road than building face/B [3] | ||
| Interior Side Yard and Rear Yard | ||||
| L | All developments (min) | 10’/B [3,4] | ||
| Building Height | ||||
| Generally | ||||
| M | Height (min), building fronting arterial roads | 30' | ||
| N | Height (max), generally [5] [6] | 70' | ||
| O | Height (max), within 100' of arterial road or property zoned or used for single-family detached dwellings | 45' | ||
Notes:
| ||||
Excluding the area for windows and doors, a minimum of 50% of the façade of the first two stories of a building fronting a road or containing a public entrance visible from a road shall be faced with stone, brick, or other masonry material similar in appearance to stone or brick.
Storefront Windows & Pedestrian Entrances. The first floor of any building façade facing a public road or common area shall incorporate storefront windows and pedestrian entrances that connect directly to the sidewalk along the road, or to a sidewalk that connects to the sidewalk along the road. Windows or pedestrian entrances shall be spaced a maximum of 10 linear feet along the front façade.
| Table 19.2-22.2 Pedestrian and Bicycle Network Proposed Improvements Summary | ||
|---|---|---|
| Road/Location | Facility Type [1] | Side of Road |
| Midlothian Turnpike | Sidewalk - Minimum 6' | North Side |
| Midlothian Turnpike | Shared Use Path | South Side |
| Woolridge Road | Bike Land and Sidewalk (existing) | Both |
| Charter Colony Parkway | Shared Use Path | East Side |
| Coalfield | Sidewalk - Minimum 5' | Both |
| Winterfield | Sidewalk - Minimum 5' | Both |
| Westfield | Bike Lane and Sidewalk | Both |
| Other/New Roads | As identified in the Infrastructure Plan Section of the Midlothian Community Special Area Plan | |
Notes:
| ||
| Table 19.2-22.2 Pedestrian and Bicycle Network Proposed Improvements Summary | ||
|---|---|---|
| Road/Location | Facility Type [1] | Side of Road |
| Midlothian Turnpike | Sidewalk - Minimum 6' | North Side |
| Midlothian Turnpike | Shared Use Path | South Side |
| Woolridge Road | Bike Land and Sidewalk (existing) | Both |
| Charter Colony Parkway | Shared Use Path | East Side |
| Coalfield | Sidewalk - Minimum 5' | Both |
| Winterfield | Sidewalk - Minimum 5' | Both |
| Westfield | Bike Lane and Sidewalk | Both |
| Other/New Roads | As identified in the Infrastructure Plan Section of the Midlothian Community Special Area Plan | |
Notes:
| ||
| Table 19.2-22.2 Pedestrian and Bicycle Network Proposed Improvements Summary | ||
|---|---|---|
| Road/Location | Facility Type [1] | Side of Road |
| Midlothian Turnpike | Sidewalk - Minimum 6' | North Side |
| Midlothian Turnpike | Shared Use Path | South Side |
| Woolridge Road | Bike Land and Sidewalk (existing) | Both |
| Charter Colony Parkway | Shared Use Path | East Side |
| Coalfield | Sidewalk - Minimum 5' | Both |
| Winterfield | Sidewalk - Minimum 5' | Both |
| Westfield | Bike Lane and Sidewalk | Both |
| Other/New Roads | As identified in the Infrastructure Plan Section of the Midlothian Community Special Area Plan | |
Notes:
| ||
| Table 19.2-22.2 Pedestrian and Bicycle Network Proposed Improvements Summary | ||
|---|---|---|
| Road/Location | Facility Type [1] | Side of Road |
| Midlothian Turnpike | Sidewalk - Minimum 6' | North Side |
| Midlothian Turnpike | Shared Use Path | South Side |
| Woolridge Road | Bike Land and Sidewalk (existing) | Both |
| Charter Colony Parkway | Shared Use Path | East Side |
| Coalfield | Sidewalk - Minimum 5' | Both |
| Winterfield | Sidewalk - Minimum 5' | Both |
| Westfield | Bike Lane and Sidewalk | Both |
| Other/New Roads | As identified in the Infrastructure Plan Section of the Midlothian Community Special Area Plan | |
Notes:
| ||
Exterior Lighting.
Streetlights. Along sidewalks adjacent to roads, pedestrian-scale streetlights shall be designed to enhance the pedestrian character of the district, spaced generally 60 feet on center and have fixture mounting heights between 12 and 15 feet above finished grade. New fixtures shall be compatible with existing fixtures within the district.
| Provisions Related to the Village Overlay District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Amenity Space | Sec. 19.2-34 |
| Buffers | Sec. 19.2-35 |
| Building Design | Sec. 19.2-36 |
| Dimensional Standards | Sec. 19.2-37 |
| Landscaping and Screening | Sec. 19.2-41 |
| Exterior Lighting | Sec. 19.2-38 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
Purpose. The Urban Corridor Overlay (UCO) District protects and enhances development along the Route 1, 10, 60, and 360 Highways in Chesterfield County. The UCO District standards:
| Figure 19.2-23.1, Urban Corridor Overlay (UCO) Maps | |
|---|---|
![]() ![]() |
| Table 19.2-23.1 Urban Corridor Overlay (UCO) Lot and Building Standards | ||||
|---|---|---|---|---|
| ' = feet | ||||
| Development | ||||
| Key | Category | Standard | ||
| A | Amenity Space (min) | 5% | ||
| Strategic Amenity Space (min) | 50% | |||
| Building Standards | ||||
| Building Setbacks (feet)/Required Perimeter Landscaping Type | ||||
| Road Type | ||||
| B | Limited Access (min) | 40'/C | ||
| C | Arterial/Other (min) | 15’/A | ||
| Interior Side Yard | ||||
| D | Adjacent to Residential Districts (min) | 10’/B | ||
| E | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 5' | ||
| Rear Yard | ||||
| J | Adjacent to Residential Districts (min) | 20’/B | ||
| K | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 5' | ||
| Parking Setbacks (feet)/Required Perimeter Landscaping | ||||
| Road Type | ||||
| L | Limited Access (min) | 40'/C | ||
| M | Arterial (min) | 15’/A | ||
| N | Other (min) | 15’/A | ||
| Interior Side Yard | ||||
| O | Adjacent to Residential Districts (min) | 15’/B (see buffer requirements) | ||
| P | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10’ [1] | ||
| Rear Yard | ||||
| Q | Adjacent to Residential Districts (min) | 20’/B (see buffer requirements) | ||
| R | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10' | ||
| Building Height | ||||
| Generally | ||||
| T | Height (max) | See Zoning District [2] | ||
| Buildings containing residential uses | ||||
| W | Height (max), within 50' of arterial road or 200' of a developed residential neighborhood | 45' [3] | ||
Notes:
| ||||
| Table 19.2-23.1 Urban Corridor Overlay (UCO) Lot and Building Standards | ||||
|---|---|---|---|---|
| ' = feet | ||||
| Development | ||||
| Key | Category | Standard | ||
| A | Amenity Space (min) | 5% | ||
| Strategic Amenity Space (min) | 50% | |||
| Building Standards | ||||
| Building Setbacks (feet)/Required Perimeter Landscaping Type | ||||
| Road Type | ||||
| B | Limited Access (min) | 40'/C | ||
| C | Arterial/Other (min) | 15’/A | ||
| Interior Side Yard | ||||
| D | Adjacent to Residential Districts (min) | 10’/B | ||
| E | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 5' | ||
| Rear Yard | ||||
| J | Adjacent to Residential Districts (min) | 20’/B | ||
| K | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 5' | ||
| Parking Setbacks (feet)/Required Perimeter Landscaping | ||||
| Road Type | ||||
| L | Limited Access (min) | 40'/C | ||
| M | Arterial (min) | 15’/A | ||
| N | Other (min) | 15’/A | ||
| Interior Side Yard | ||||
| O | Adjacent to Residential Districts (min) | 15’/B (see buffer requirements) | ||
| P | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10’ [1] | ||
| Rear Yard | ||||
| Q | Adjacent to Residential Districts (min) | 20’/B (see buffer requirements) | ||
| R | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10' | ||
| Building Height | ||||
| Generally | ||||
| T | Height (max) | See Zoning District [2] | ||
| Buildings containing residential uses | ||||
| W | Height (max), within 50' of arterial road or 200' of a developed residential neighborhood | 45' [3] | ||
Notes:
| ||||
| Table 19.2-23.1 Urban Corridor Overlay (UCO) Lot and Building Standards | ||||
|---|---|---|---|---|
| ' = feet | ||||
| Development | ||||
| Key | Category | Standard | ||
| A | Amenity Space (min) | 5% | ||
| Strategic Amenity Space (min) | 50% | |||
| Building Standards | ||||
| Building Setbacks (feet)/Required Perimeter Landscaping Type | ||||
| Road Type | ||||
| B | Limited Access (min) | 40'/C | ||
| C | Arterial/Other (min) | 15’/A | ||
| Interior Side Yard | ||||
| D | Adjacent to Residential Districts (min) | 10’/B | ||
| E | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 5' | ||
| Rear Yard | ||||
| J | Adjacent to Residential Districts (min) | 20’/B | ||
| K | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 5' | ||
| Parking Setbacks (feet)/Required Perimeter Landscaping | ||||
| Road Type | ||||
| L | Limited Access (min) | 40'/C | ||
| M | Arterial (min) | 15’/A | ||
| N | Other (min) | 15’/A | ||
| Interior Side Yard | ||||
| O | Adjacent to Residential Districts (min) | 15’/B (see buffer requirements) | ||
| P | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10’ [1] | ||
| Rear Yard | ||||
| Q | Adjacent to Residential Districts (min) | 20’/B (see buffer requirements) | ||
| R | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10' | ||
| Building Height | ||||
| Generally | ||||
| T | Height (max) | See Zoning District [2] | ||
| Buildings containing residential uses | ||||
| W | Height (max), within 50' of arterial road or 200' of a developed residential neighborhood | 45' [3] | ||
Notes:
| ||||
| Table 19.2-23.1 Urban Corridor Overlay (UCO) Lot and Building Standards | ||||
|---|---|---|---|---|
| ' = feet | ||||
| Development | ||||
| Key | Category | Standard | ||
| A | Amenity Space (min) | 5% | ||
| Strategic Amenity Space (min) | 50% | |||
| Building Standards | ||||
| Building Setbacks (feet)/Required Perimeter Landscaping Type | ||||
| Road Type | ||||
| B | Limited Access (min) | 40'/C | ||
| C | Arterial/Other (min) | 15’/A | ||
| Interior Side Yard | ||||
| D | Adjacent to Residential Districts (min) | 10’/B | ||
| E | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 5' | ||
| Rear Yard | ||||
| J | Adjacent to Residential Districts (min) | 20’/B | ||
| K | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 5' | ||
| Parking Setbacks (feet)/Required Perimeter Landscaping | ||||
| Road Type | ||||
| L | Limited Access (min) | 40'/C | ||
| M | Arterial (min) | 15’/A | ||
| N | Other (min) | 15’/A | ||
| Interior Side Yard | ||||
| O | Adjacent to Residential Districts (min) | 15’/B (see buffer requirements) | ||
| P | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10’ [1] | ||
| Rear Yard | ||||
| Q | Adjacent to Residential Districts (min) | 20’/B (see buffer requirements) | ||
| R | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10' | ||
| Building Height | ||||
| Generally | ||||
| T | Height (max) | See Zoning District [2] | ||
| Buildings containing residential uses | ||||
| W | Height (max), within 50' of arterial road or 200' of a developed residential neighborhood | 45' [3] | ||
Notes:
| ||||
Exterior Lighting.
Streetlights. Along sidewalks adjacent to roads, pedestrian-scale streetlights shall be designed to enhance the pedestrian character of the district, spaced generally 60 feet on center and have fixture mounting heights between 12 and 15 feet above finished grade. New fixtures shall be compatible with existing fixtures within the district.
| Provisions Related to the Urban Corridor Overlay District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Amenity Space | Sec. 19.2-34 |
| Buffers | Sec. 19.2-35 |
| Building Design | Sec. 19.2-36 |
| Dimensional Standards | Sec. 19.2-37 |
| Landscaping and Screening | Sec. 19.2-41 |
| Exterior Lighting | Sec. 19.2-38 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
Purpose: The Roseland Zoning Overlay (RZO) District provides for a high-quality master- planned mixed-use community. It is the intent of this District to allow for flexibility while maintaining the high-quality development concepts envisioned by the approved Roseland rezoning (Zoning Case 07SN0223) along with the guiding principles as set forth below:
The provisions of this district shall not supersede the approved conditions of Zoning Case 07SN0223. Upon adoption, zoning approval for individual ownership tracts may be obtained, with more specific land uses and design details being provided for each development tract. Any rezoning request submitted on property located within the RZO boundaries shall comply with the standards provided herein and as otherwise required by the Chesterfield County Zoning Ordinance, unless otherwise granted by the Chesterfield County Board of Supervisors where such approval would advance the guiding principles above. Once rezoning is granted on an individual development tract, the conditions of Zoning Case 07SN0223 shall be null and void within such tract.
That this ordinance shall become effective immediately after adoption.
The RZO is comprised of the following area as shown on the zoning maps, and as shaded in Figure 19.2-24.1.:
| Figure: 19.2-24.1. |
![]() |
The purpose of the Master Plan is to serve as a conceptual development guide for the RZO. The Master Plan is general in nature and provides for flexibility of overall uses while depicting desirable locations for higher-density and/or mixed-use nodes throughout the RZO, as well as flexibility for road alignments throughout individual projects so long as connection points to adjoining roads and/or parcels are in the general locations illustrated in the Master Plan below. The locations of specific uses shall be determined at the time of rezoning and plans review, or as otherwise required by the Zoning Ordinance through Schematic Plan approval. The Master Plan is displayed in Figure 19.2-24.2.:
| Figure: 19.2-24.2. |
![]() |
The RZO shall be comprised of the following Use Districts, as depicted in Figure 19.2-24.3. below. Descriptions of these Use Districts and their permitted uses are provided as follows in subsection D through G.
| Figure: 19.2-24.3. |
![]() |
The purpose of the Suburban Residential District is to provide for lower density detached single-family dwelling development comparable to that found in the Hallsley community. Uses permitted in this district shall be limited to those permitted within the SC District, subject to the standards provided in Section 19.2-24.K.1. and 19.2-24.K.4.
| Table: 19.2-24.1. | |||||
| Development Tracts | Acreage (approx.) | Single‐Family | Townhome (and similar attached units) | Multi‐Family (apartment/condo) | Non‐Residential |
| Tract A | 777.5 total | ||||
| A.1. East of Woolridge Rd. | 326.6 | 300 | 300 | 500 | 500,000 |
| A.2. North Hallsley | 302.5 | 340 | 0 | 0 | 0 |
| A.3. West of Woolridge Rd./east of Otterdale Rd. | 42.3 | 0 | 0 | 250 | 30,000 |
| A.4. North of Old Hundred Rd. | 106.1 | 80 | 120 | 250 | 30,000 |
| Tract B | |||||
| 272.5 | 333 | 333 | 333 | 60,000 | |
| Tract C | |||||
| Note: Max. 200 dwelling units on this Tract | 95.4 | 200 | Max. 50 of the 200 units | Max. 50 of the 200 units | 15,000 |
| Tract D | |||||
| Note: Max. 525 dwelling units on this Tract | 117 | Max. 100 of the 525 units | 325 | 200 | 180,000 |
| Tract E | |||||
| 115.2 | 0 | 237 | 168 | 0 | |
| Tract F | |||||
| 30.2 | 91 | OR 240 | 0 | 0 | |
| Tract G | |||||
| Public Facilities Only | 81.5 | 0 | 0 | 0 | 0 |
| Totals | 1489.3 | 4,509 total residential units | 815,000 total sq. ft. | ||
![]() | |||||
Figure 19.2-24.4. below shows the conceptual routing of roads (arterial, collector and local roads) within the RZO. The alignments of the major roads would connect to adjacent roads and/or neighboring projects in the general locations illustrated in the figure below. Otherwise, these routes are general in nature and depict a hierarchy of street types in order to support the desired development pattern in Roseland. The alignment of each major road within a particular project shall be determined by the property owner(s) during the rezoning and/or plans review process, subject to approval by the Transportation Department. For local roads, the alignment and connection points to other roads shall be determined by the property owner(s) and as approved by the Transportation Department during the rezoning process and/or plans review process, notwithstanding what is shown below.
| Figure: 19.2-24.4. |
![]() |
| Table 19.2-24.2. Required Standards - Street Design | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Street Sections[1] | Details | |||||||||||
| Major Arterials | ||||||||||||
| Section A. | Applicable to Brightwalton Rd. from the current terminus in Hallsley to Mt. Hermon Rd., or for Roseland Ave. between Otterdale Rd. and Old Hundred Rd. | |||||||||||
| Section B.1. | Applicable to any segment of Roseland Ave. and Brightwalton Rd. (non-residential uses may front where acceptable to Director of Planning [2]) | |||||||||||
| Section B.2. (four travel lanes) | Applicable to any segment of Roseland Ave. and Brightwalton Rd. (non-residential uses may front where acceptable to Director of Planning [2]) | |||||||||||
| Section C.1. | Applicable to any segment of Roseland Ave. and Brightwalton Rd./Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Section C.2. (four travel lanes) | Applicable to any segment of Roseland Ave. and Brightwalton Rd./Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Collectors | ||||||||||||
| Section D.1. | Applicable to any Collector where residential uses front | |||||||||||
| Section D.2. | Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Local Streets | ||||||||||||
| Section E.1. | Applicable where residential uses front | |||||||||||
| Section E.2. | Applicable where residential uses front | |||||||||||
| Section E.3. | Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Section F (option for one-way travel) | Mews Street | |||||||||||
| Design Requirements (details) | Street Sections | |||||||||||
| Buildings do not front/buffers required on abutting residential subdivisions | A. | |||||||||||
| Buildings front/residential lots are rear-loaded | B.1. | B.2. | C.1. | C.2. | D.1. | D.2. | E.2. | E.3. | ||||
| Street trees | B.1. | B.2. | C.1. | C.2. | D.1. | D.2. | E.1. | E.2. | E.3. | |||
| Buffer strips (minimum 6 feet wide between back of curb and edge of sidewalk) | B.1. | B.2. | D.1. | E.1. | E.2. | |||||||
| Street tree fixtures such as tree grates, tree wells, or planter boxes | C.1. | C.2. | D.2. | E.3. | ||||||||
| Sidewalks on both sides, except for Roseland Ave., or as otherwise permitted by Section 19.2-24.I.1.d. | A. | C.1. | C.2. | D.1. | D.2. | E.1. | E.2. | E.3. | ||||
| Sidewalk on one side | B.1. | B.2. | F. | |||||||||
| Sidewalks shall extend to the edge of the street curb. Treatment shall consist of a combination of materials such as concrete, brick, or pavers | C.1. | C.2. | D.2. | E.3. | ||||||||
| Shared-use path on one side (optional for Brightwalton Rd.) | A. | B.1. | B.2. | |||||||||
| Sidewalks and shared-use paths may meander through landscaped areas or buffers (outside r.o.w.) | A. | |||||||||||
| On-street parking | C.1. | C.2. | D.1. | D.2. | E.1. | E.2. | E.3. | |||||
| On-street parking clearly identified | C.1. | C.2. | D.1. | D.2. | E.2. | E.3. | ||||||
| Provides road frontage for a maximum of 10 single-family lots | F. | |||||||||||
| Wide median accommodates future phased expansion for additional travel lanes | B.1. | C.1. | ||||||||||
| The Director of Planning may grant flexibility regarding the provision of on-street parking and/or sidewalk improvements where one side of the road is developed for non-residential development and the opposite side is developed for residential or lower-intensity development, or one side of such road abuts a park, common area or environmental feature. The aforementioned improvements may then be applied to one side of such road | C.1. | C.2. | D.1. | D.2. | E.2. | E.3. | ||||||
Notes:
| ||||||||||||
| Table 19.2-24.2. Required Standards - Street Design | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Street Sections[1] | Details | |||||||||||
| Major Arterials | ||||||||||||
| Section A. | Applicable to Brightwalton Rd. from the current terminus in Hallsley to Mt. Hermon Rd., or for Roseland Ave. between Otterdale Rd. and Old Hundred Rd. | |||||||||||
| Section B.1. | Applicable to any segment of Roseland Ave. and Brightwalton Rd. (non-residential uses may front where acceptable to Director of Planning [2]) | |||||||||||
| Section B.2. (four travel lanes) | Applicable to any segment of Roseland Ave. and Brightwalton Rd. (non-residential uses may front where acceptable to Director of Planning [2]) | |||||||||||
| Section C.1. | Applicable to any segment of Roseland Ave. and Brightwalton Rd./Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Section C.2. (four travel lanes) | Applicable to any segment of Roseland Ave. and Brightwalton Rd./Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Collectors | ||||||||||||
| Section D.1. | Applicable to any Collector where residential uses front | |||||||||||
| Section D.2. | Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Local Streets | ||||||||||||
| Section E.1. | Applicable where residential uses front | |||||||||||
| Section E.2. | Applicable where residential uses front | |||||||||||
| Section E.3. | Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Section F (option for one-way travel) | Mews Street | |||||||||||
| Design Requirements (details) | Street Sections | |||||||||||
| Buildings do not front/buffers required on abutting residential subdivisions | A. | |||||||||||
| Buildings front/residential lots are rear-loaded | B.1. | B.2. | C.1. | C.2. | D.1. | D.2. | E.2. | E.3. | ||||
| Street trees | B.1. | B.2. | C.1. | C.2. | D.1. | D.2. | E.1. | E.2. | E.3. | |||
| Buffer strips (minimum 6 feet wide between back of curb and edge of sidewalk) | B.1. | B.2. | D.1. | E.1. | E.2. | |||||||
| Street tree fixtures such as tree grates, tree wells, or planter boxes | C.1. | C.2. | D.2. | E.3. | ||||||||
| Sidewalks on both sides, except for Roseland Ave., or as otherwise permitted by Section 19.2-24.I.1.d. | A. | C.1. | C.2. | D.1. | D.2. | E.1. | E.2. | E.3. | ||||
| Sidewalk on one side | B.1. | B.2. | F. | |||||||||
| Sidewalks shall extend to the edge of the street curb. Treatment shall consist of a combination of materials such as concrete, brick, or pavers | C.1. | C.2. | D.2. | E.3. | ||||||||
| Shared-use path on one side (optional for Brightwalton Rd.) | A. | B.1. | B.2. | |||||||||
| Sidewalks and shared-use paths may meander through landscaped areas or buffers (outside r.o.w.) | A. | |||||||||||
| On-street parking | C.1. | C.2. | D.1. | D.2. | E.1. | E.2. | E.3. | |||||
| On-street parking clearly identified | C.1. | C.2. | D.1. | D.2. | E.2. | E.3. | ||||||
| Provides road frontage for a maximum of 10 single-family lots | F. | |||||||||||
| Wide median accommodates future phased expansion for additional travel lanes | B.1. | C.1. | ||||||||||
| The Director of Planning may grant flexibility regarding the provision of on-street parking and/or sidewalk improvements where one side of the road is developed for non-residential development and the opposite side is developed for residential or lower-intensity development, or one side of such road abuts a park, common area or environmental feature. The aforementioned improvements may then be applied to one side of such road | C.1. | C.2. | D.1. | D.2. | E.2. | E.3. | ||||||
Notes:
| ||||||||||||
| Table 19.2-24.2. Required Standards - Street Design | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Street Sections[1] | Details | |||||||||||
| Major Arterials | ||||||||||||
| Section A. | Applicable to Brightwalton Rd. from the current terminus in Hallsley to Mt. Hermon Rd., or for Roseland Ave. between Otterdale Rd. and Old Hundred Rd. | |||||||||||
| Section B.1. | Applicable to any segment of Roseland Ave. and Brightwalton Rd. (non-residential uses may front where acceptable to Director of Planning [2]) | |||||||||||
| Section B.2. (four travel lanes) | Applicable to any segment of Roseland Ave. and Brightwalton Rd. (non-residential uses may front where acceptable to Director of Planning [2]) | |||||||||||
| Section C.1. | Applicable to any segment of Roseland Ave. and Brightwalton Rd./Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Section C.2. (four travel lanes) | Applicable to any segment of Roseland Ave. and Brightwalton Rd./Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Collectors | ||||||||||||
| Section D.1. | Applicable to any Collector where residential uses front | |||||||||||
| Section D.2. | Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Local Streets | ||||||||||||
| Section E.1. | Applicable where residential uses front | |||||||||||
| Section E.2. | Applicable where residential uses front | |||||||||||
| Section E.3. | Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Section F (option for one-way travel) | Mews Street | |||||||||||
| Design Requirements (details) | Street Sections | |||||||||||
| Buildings do not front/buffers required on abutting residential subdivisions | A. | |||||||||||
| Buildings front/residential lots are rear-loaded | B.1. | B.2. | C.1. | C.2. | D.1. | D.2. | E.2. | E.3. | ||||
| Street trees | B.1. | B.2. | C.1. | C.2. | D.1. | D.2. | E.1. | E.2. | E.3. | |||
| Buffer strips (minimum 6 feet wide between back of curb and edge of sidewalk) | B.1. | B.2. | D.1. | E.1. | E.2. | |||||||
| Street tree fixtures such as tree grates, tree wells, or planter boxes | C.1. | C.2. | D.2. | E.3. | ||||||||
| Sidewalks on both sides, except for Roseland Ave., or as otherwise permitted by Section 19.2-24.I.1.d. | A. | C.1. | C.2. | D.1. | D.2. | E.1. | E.2. | E.3. | ||||
| Sidewalk on one side | B.1. | B.2. | F. | |||||||||
| Sidewalks shall extend to the edge of the street curb. Treatment shall consist of a combination of materials such as concrete, brick, or pavers | C.1. | C.2. | D.2. | E.3. | ||||||||
| Shared-use path on one side (optional for Brightwalton Rd.) | A. | B.1. | B.2. | |||||||||
| Sidewalks and shared-use paths may meander through landscaped areas or buffers (outside r.o.w.) | A. | |||||||||||
| On-street parking | C.1. | C.2. | D.1. | D.2. | E.1. | E.2. | E.3. | |||||
| On-street parking clearly identified | C.1. | C.2. | D.1. | D.2. | E.2. | E.3. | ||||||
| Provides road frontage for a maximum of 10 single-family lots | F. | |||||||||||
| Wide median accommodates future phased expansion for additional travel lanes | B.1. | C.1. | ||||||||||
| The Director of Planning may grant flexibility regarding the provision of on-street parking and/or sidewalk improvements where one side of the road is developed for non-residential development and the opposite side is developed for residential or lower-intensity development, or one side of such road abuts a park, common area or environmental feature. The aforementioned improvements may then be applied to one side of such road | C.1. | C.2. | D.1. | D.2. | E.2. | E.3. | ||||||
Notes:
| ||||||||||||
| Table 19.2-24.2. Required Standards - Street Design | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Street Sections[1] | Details | |||||||||||
| Major Arterials | ||||||||||||
| Section A. | Applicable to Brightwalton Rd. from the current terminus in Hallsley to Mt. Hermon Rd., or for Roseland Ave. between Otterdale Rd. and Old Hundred Rd. | |||||||||||
| Section B.1. | Applicable to any segment of Roseland Ave. and Brightwalton Rd. (non-residential uses may front where acceptable to Director of Planning [2]) | |||||||||||
| Section B.2. (four travel lanes) | Applicable to any segment of Roseland Ave. and Brightwalton Rd. (non-residential uses may front where acceptable to Director of Planning [2]) | |||||||||||
| Section C.1. | Applicable to any segment of Roseland Ave. and Brightwalton Rd./Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Section C.2. (four travel lanes) | Applicable to any segment of Roseland Ave. and Brightwalton Rd./Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Collectors | ||||||||||||
| Section D.1. | Applicable to any Collector where residential uses front | |||||||||||
| Section D.2. | Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Local Streets | ||||||||||||
| Section E.1. | Applicable where residential uses front | |||||||||||
| Section E.2. | Applicable where residential uses front | |||||||||||
| Section E.3. | Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Section F (option for one-way travel) | Mews Street | |||||||||||
| Design Requirements (details) | Street Sections | |||||||||||
| Buildings do not front/buffers required on abutting residential subdivisions | A. | |||||||||||
| Buildings front/residential lots are rear-loaded | B.1. | B.2. | C.1. | C.2. | D.1. | D.2. | E.2. | E.3. | ||||
| Street trees | B.1. | B.2. | C.1. | C.2. | D.1. | D.2. | E.1. | E.2. | E.3. | |||
| Buffer strips (minimum 6 feet wide between back of curb and edge of sidewalk) | B.1. | B.2. | D.1. | E.1. | E.2. | |||||||
| Street tree fixtures such as tree grates, tree wells, or planter boxes | C.1. | C.2. | D.2. | E.3. | ||||||||
| Sidewalks on both sides, except for Roseland Ave., or as otherwise permitted by Section 19.2-24.I.1.d. | A. | C.1. | C.2. | D.1. | D.2. | E.1. | E.2. | E.3. | ||||
| Sidewalk on one side | B.1. | B.2. | F. | |||||||||
| Sidewalks shall extend to the edge of the street curb. Treatment shall consist of a combination of materials such as concrete, brick, or pavers | C.1. | C.2. | D.2. | E.3. | ||||||||
| Shared-use path on one side (optional for Brightwalton Rd.) | A. | B.1. | B.2. | |||||||||
| Sidewalks and shared-use paths may meander through landscaped areas or buffers (outside r.o.w.) | A. | |||||||||||
| On-street parking | C.1. | C.2. | D.1. | D.2. | E.1. | E.2. | E.3. | |||||
| On-street parking clearly identified | C.1. | C.2. | D.1. | D.2. | E.2. | E.3. | ||||||
| Provides road frontage for a maximum of 10 single-family lots | F. | |||||||||||
| Wide median accommodates future phased expansion for additional travel lanes | B.1. | C.1. | ||||||||||
| The Director of Planning may grant flexibility regarding the provision of on-street parking and/or sidewalk improvements where one side of the road is developed for non-residential development and the opposite side is developed for residential or lower-intensity development, or one side of such road abuts a park, common area or environmental feature. The aforementioned improvements may then be applied to one side of such road | C.1. | C.2. | D.1. | D.2. | E.2. | E.3. | ||||||
Notes:
| ||||||||||||







| Section E.1. | Section E.2. |
![]() | ![]() |
| Section E.3 | |
![]() |
| Section F. | |
![]() | ![]() |
| Figure: 19.2-24.5 |
![]() |
| Table 19.2-24.3 Required Conditions for Suburban Residential District | ||
|---|---|---|
| Lots | For lots sharing a property boundary with Linear Park | |
| ||
| ||
| 15,000[1] | 11,500 |
| 100 | 70 |
| 30 | 40 |
| ||
| ||
| 30 | 30 |
| 30 | 30 |
| 50 | 50 |
| ||
| ||
| 40 | 40 |
| 25 | 25 |
| 15 (10 to porches) | |
| 15 | 10 (15 when abutting lots are ≥ 15,000 sq. ft. |
| 35 | 30 |
| ||
| 25 | 25 |
| 40 | 40 |
Notes for Table 19.2-24.3
| ||
| Table 19.2-24.3 Required Conditions for Suburban Residential District | ||
|---|---|---|
| Lots | For lots sharing a property boundary with Linear Park | |
| ||
| ||
| 15,000[1] | 11,500 |
| 100 | 70 |
| 30 | 40 |
| ||
| ||
| 30 | 30 |
| 30 | 30 |
| 50 | 50 |
| ||
| ||
| 40 | 40 |
| 25 | 25 |
| 15 (10 to porches) | |
| 15 | 10 (15 when abutting lots are ≥ 15,000 sq. ft. |
| 35 | 30 |
| ||
| 25 | 25 |
| 40 | 40 |
Notes for Table 19.2-24.3
| ||
| Table 19.2-24.3 Required Conditions for Suburban Residential District | ||
|---|---|---|
| Lots | For lots sharing a property boundary with Linear Park | |
| ||
| ||
| 15,000[1] | 11,500 |
| 100 | 70 |
| 30 | 40 |
| ||
| ||
| 30 | 30 |
| 30 | 30 |
| 50 | 50 |
| ||
| ||
| 40 | 40 |
| 25 | 25 |
| 15 (10 to porches) | |
| 15 | 10 (15 when abutting lots are ≥ 15,000 sq. ft. |
| 35 | 30 |
| ||
| 25 | 25 |
| 40 | 40 |
Notes for Table 19.2-24.3
| ||
| Table 19.2-24.3 Required Conditions for Suburban Residential District | ||
|---|---|---|
| Lots | For lots sharing a property boundary with Linear Park | |
| ||
| ||
| 15,000[1] | 11,500 |
| 100 | 70 |
| 30 | 40 |
| ||
| ||
| 30 | 30 |
| 30 | 30 |
| 50 | 50 |
| ||
| ||
| 40 | 40 |
| 25 | 25 |
| 15 (10 to porches) | |
| 15 | 10 (15 when abutting lots are ≥ 15,000 sq. ft. |
| 35 | 30 |
| ||
| 25 | 25 |
| 40 | 40 |
Notes for Table 19.2-24.3
| ||
| Table 19.2-24.4 Required Conditions for Medium-Density Residential with Nodal Mixed-Use District | |
|---|---|
| |
| |
| 5,000 (3,500 when fronting on and having a main/front entrance facing the Linear Park or Amenity Space) |
| 40 |
| 50 |
| |
| |
| 30 |
| 20 |
| 40 |
| |
| |
| 20 (15 to porches) |
| 15 (10 to porches) |
| 10 (5 to porches) |
| 5 |
| 15 |
| |
| 20 |
| 10[5] (rear-loaded) |
| 25 |
| |
| 1 one side[6], 3 one side |
| 5 on each side |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.4
| |
| Table 19.2-24.4 Required Conditions for Medium-Density Residential with Nodal Mixed-Use District | |
|---|---|
| |
| |
| 5,000 (3,500 when fronting on and having a main/front entrance facing the Linear Park or Amenity Space) |
| 40 |
| 50 |
| |
| |
| 30 |
| 20 |
| 40 |
| |
| |
| 20 (15 to porches) |
| 15 (10 to porches) |
| 10 (5 to porches) |
| 5 |
| 15 |
| |
| 20 |
| 10[5] (rear-loaded) |
| 25 |
| |
| 1 one side[6], 3 one side |
| 5 on each side |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.4
| |
| Table 19.2-24.4 Required Conditions for Medium-Density Residential with Nodal Mixed-Use District | |
|---|---|
| |
| |
| 5,000 (3,500 when fronting on and having a main/front entrance facing the Linear Park or Amenity Space) |
| 40 |
| 50 |
| |
| |
| 30 |
| 20 |
| 40 |
| |
| |
| 20 (15 to porches) |
| 15 (10 to porches) |
| 10 (5 to porches) |
| 5 |
| 15 |
| |
| 20 |
| 10[5] (rear-loaded) |
| 25 |
| |
| 1 one side[6], 3 one side |
| 5 on each side |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.4
| |
| Table 19.2-24.4 Required Conditions for Medium-Density Residential with Nodal Mixed-Use District | |
|---|---|
| |
| |
| 5,000 (3,500 when fronting on and having a main/front entrance facing the Linear Park or Amenity Space) |
| 40 |
| 50 |
| |
| |
| 30 |
| 20 |
| 40 |
| |
| |
| 20 (15 to porches) |
| 15 (10 to porches) |
| 10 (5 to porches) |
| 5 |
| 15 |
| |
| 20 |
| 10[5] (rear-loaded) |
| 25 |
| |
| 1 one side[6], 3 one side |
| 5 on each side |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.4
| |
| Table 19.2-24.5 Required Conditions for Commercial/High- Density Residential/Mixed-Use District | |
|---|---|
| |
| |
| 5,000 (3,500 when fronting on and having a main/front entrance facing the Linear Park or Amenity Space) |
| 40 |
| 50 |
| |
| |
| 30 |
| 20 |
| 40 |
| |
| |
| 20 (15 to porches) |
| 15 (10 to porches) |
| 10 (5 to porches) |
| 5 |
| 15 |
| |
| 10[5] (rear-loaded) |
| |
| 1 one side[6], 3 one side |
| 5 on each side |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.5
| |
| Table 19.2-24.5 Required Conditions for Commercial/High- Density Residential/Mixed-Use District | |
|---|---|
| |
| |
| 5,000 (3,500 when fronting on and having a main/front entrance facing the Linear Park or Amenity Space) |
| 40 |
| 50 |
| |
| |
| 30 |
| 20 |
| 40 |
| |
| |
| 20 (15 to porches) |
| 15 (10 to porches) |
| 10 (5 to porches) |
| 5 |
| 15 |
| |
| 10[5] (rear-loaded) |
| |
| 1 one side[6], 3 one side |
| 5 on each side |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.5
| |
| Table 19.2-24.5 Required Conditions for Commercial/High- Density Residential/Mixed-Use District | |
|---|---|
| |
| |
| 5,000 (3,500 when fronting on and having a main/front entrance facing the Linear Park or Amenity Space) |
| 40 |
| 50 |
| |
| |
| 30 |
| 20 |
| 40 |
| |
| |
| 20 (15 to porches) |
| 15 (10 to porches) |
| 10 (5 to porches) |
| 5 |
| 15 |
| |
| 10[5] (rear-loaded) |
| |
| 1 one side[6], 3 one side |
| 5 on each side |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.5
| |
| Table 19.2-24.5 Required Conditions for Commercial/High- Density Residential/Mixed-Use District | |
|---|---|
| |
| |
| 5,000 (3,500 when fronting on and having a main/front entrance facing the Linear Park or Amenity Space) |
| 40 |
| 50 |
| |
| |
| 30 |
| 20 |
| 40 |
| |
| |
| 20 (15 to porches) |
| 15 (10 to porches) |
| 10 (5 to porches) |
| 5 |
| 15 |
| |
| 10[5] (rear-loaded) |
| |
| 1 one side[6], 3 one side |
| 5 on each side |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.5
| |
| Table 19.2-24.6 Required Conditions for Medium- Density Residential with Nodal Mixed-Use District | |
|---|---|
| |
| 5 ac |
| No max. |
| |
| 50 where not rear-loaded |
| 15 where not rear-loaded |
| See Section 19.2-24.J. |
| 10 |
| |
| 1,500 |
| 16 |
| 50, 70 (where rear-loaded) |
| |
| |
| 50 |
| 15 (10 to porches) |
| 15 (10 to porches) |
| 8 |
| 15[6] |
| |
| 10 |
| 20 |
| |
| 3 stories |
| 4 stories |
| |
| None required |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.6
| |
| Table 19.2-24.6 Required Conditions for Medium- Density Residential with Nodal Mixed-Use District | |
|---|---|
| |
| 5 ac |
| No max. |
| |
| 50 where not rear-loaded |
| 15 where not rear-loaded |
| See Section 19.2-24.J. |
| 10 |
| |
| 1,500 |
| 16 |
| 50, 70 (where rear-loaded) |
| |
| |
| 50 |
| 15 (10 to porches) |
| 15 (10 to porches) |
| 8 |
| 15[6] |
| |
| 10 |
| 20 |
| |
| 3 stories |
| 4 stories |
| |
| None required |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.6
| |
| Table 19.2-24.6 Required Conditions for Medium- Density Residential with Nodal Mixed-Use District | |
|---|---|
| |
| 5 ac |
| No max. |
| |
| 50 where not rear-loaded |
| 15 where not rear-loaded |
| See Section 19.2-24.J. |
| 10 |
| |
| 1,500 |
| 16 |
| 50, 70 (where rear-loaded) |
| |
| |
| 50 |
| 15 (10 to porches) |
| 15 (10 to porches) |
| 8 |
| 15[6] |
| |
| 10 |
| 20 |
| |
| 3 stories |
| 4 stories |
| |
| None required |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.6
| |
| Table 19.2-24.6 Required Conditions for Medium- Density Residential with Nodal Mixed-Use District | |
|---|---|
| |
| 5 ac |
| No max. |
| |
| 50 where not rear-loaded |
| 15 where not rear-loaded |
| See Section 19.2-24.J. |
| 10 |
| |
| 1,500 |
| 16 |
| 50, 70 (where rear-loaded) |
| |
| |
| 50 |
| 15 (10 to porches) |
| 15 (10 to porches) |
| 8 |
| 15[6] |
| |
| 10 |
| 20 |
| |
| 3 stories |
| 4 stories |
| |
| None required |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.6
| |
| Table 19.2-24.7 Required Conditions for Commercial/High-Density Residential/Mixed-Use District | |
|---|---|
| |
| No min. |
| No max. |
| See Section19.2-24.J. |
| 15 |
| |
| 1,400 |
| 16 |
| 75 |
| |
| |
| 50 |
| 15 (10 to porches) |
| |
| 15 (10 to porches) |
| 10 (5 to porches) |
| 5 |
| |
| 15 (10 to porches) |
| 10 (5 to porches) |
| |
| 10 |
| 20 |
| 4 stories |
| |
| None required |
| 10 for local streets, 15 for collectors |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.7
| |
| Table 19.2-24.7 Required Conditions for Commercial/High-Density Residential/Mixed-Use District | |
|---|---|
| |
| No min. |
| No max. |
| See Section19.2-24.J. |
| 15 |
| |
| 1,400 |
| 16 |
| 75 |
| |
| |
| 50 |
| 15 (10 to porches) |
| |
| 15 (10 to porches) |
| 10 (5 to porches) |
| 5 |
| |
| 15 (10 to porches) |
| 10 (5 to porches) |
| |
| 10 |
| 20 |
| 4 stories |
| |
| None required |
| 10 for local streets, 15 for collectors |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.7
| |
| Table 19.2-24.7 Required Conditions for Commercial/High-Density Residential/Mixed-Use District | |
|---|---|
| |
| No min. |
| No max. |
| See Section19.2-24.J. |
| 15 |
| |
| 1,400 |
| 16 |
| 75 |
| |
| |
| 50 |
| 15 (10 to porches) |
| |
| 15 (10 to porches) |
| 10 (5 to porches) |
| 5 |
| |
| 15 (10 to porches) |
| 10 (5 to porches) |
| |
| 10 |
| 20 |
| 4 stories |
| |
| None required |
| 10 for local streets, 15 for collectors |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.7
| |
| Table 19.2-24.7 Required Conditions for Commercial/High-Density Residential/Mixed-Use District | |
|---|---|
| |
| No min. |
| No max. |
| See Section19.2-24.J. |
| 15 |
| |
| 1,400 |
| 16 |
| 75 |
| |
| |
| 50 |
| 15 (10 to porches) |
| |
| 15 (10 to porches) |
| 10 (5 to porches) |
| 5 |
| |
| 15 (10 to porches) |
| 10 (5 to porches) |
| |
| 10 |
| 20 |
| 4 stories |
| |
| None required |
| 10 for local streets, 15 for collectors |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.7
| |
| Table 19.2-24.8 Required Conditions for Medium-Density Residential with Nodal Mixed-Use District | |
|---|---|
| Project Standards | |
| 5 acres, no min. when non-residential uses are included within a building |
| |
| 1 |
| 2 |
| [2] |
| 30 |
| 24 |
| 50[3] |
Notes for Table 19.2-24.8
| |
| Table 19.2-24.8 Required Conditions for Medium-Density Residential with Nodal Mixed-Use District | |
|---|---|
| Project Standards | |
| 5 acres, no min. when non-residential uses are included within a building |
| |
| 1 |
| 2 |
| [2] |
| 30 |
| 24 |
| 50[3] |
Notes for Table 19.2-24.8
| |
| Table 19.2-24.8 Required Conditions for Medium-Density Residential with Nodal Mixed-Use District | |
|---|---|
| Project Standards | |
| 5 acres, no min. when non-residential uses are included within a building |
| |
| 1 |
| 2 |
| [2] |
| 30 |
| 24 |
| 50[3] |
Notes for Table 19.2-24.8
| |
| Table 19.2-24.8 Required Conditions for Medium-Density Residential with Nodal Mixed-Use District | |
|---|---|
| Project Standards | |
| 5 acres, no min. when non-residential uses are included within a building |
| |
| 1 |
| 2 |
| [2] |
| 30 |
| 24 |
| 50[3] |
Notes for Table 19.2-24.8
| |
| Table 19.2-24.9 Required Conditions for Medium-Density Residential with Nodal Mixed-Use District | |
|---|---|
| Building Standards | |
| |
| |
| 10, No Perimeter Landscaping required |
| No setback or Perimeter Landscaping required |
| |
| 15/A[4] |
| 40/C |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| None required |
| None required |
| None required |
| No maximum |
| |
| 3 stories |
| 8 stories |
| |
| Same as principal buildings |
Notes for Table 19.2-24.9
| |
| Table 19.2-24.9 Required Conditions for Medium-Density Residential with Nodal Mixed-Use District | |
|---|---|
| Building Standards | |
| |
| |
| 10, No Perimeter Landscaping required |
| No setback or Perimeter Landscaping required |
| |
| 15/A[4] |
| 40/C |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| None required |
| None required |
| None required |
| No maximum |
| |
| 3 stories |
| 8 stories |
| |
| Same as principal buildings |
Notes for Table 19.2-24.9
| |
| Table 19.2-24.9 Required Conditions for Medium-Density Residential with Nodal Mixed-Use District | |
|---|---|
| Building Standards | |
| |
| |
| 10, No Perimeter Landscaping required |
| No setback or Perimeter Landscaping required |
| |
| 15/A[4] |
| 40/C |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| None required |
| None required |
| None required |
| No maximum |
| |
| 3 stories |
| 8 stories |
| |
| Same as principal buildings |
Notes for Table 19.2-24.9
| |
| Table 19.2-24.9 Required Conditions for Medium-Density Residential with Nodal Mixed-Use District | |
|---|---|
| Building Standards | |
| |
| |
| 10, No Perimeter Landscaping required |
| No setback or Perimeter Landscaping required |
| |
| 15/A[4] |
| 40/C |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| None required |
| None required |
| None required |
| No maximum |
| |
| 3 stories |
| 8 stories |
| |
| Same as principal buildings |
Notes for Table 19.2-24.9
| |
| Table 19.2-24.10 Required Conditions for Commercial/High-Density Residential/Mixed-Use District | |
|---|---|
| Project Standards | |
| None required |
| |
| 1 |
| 2 |
| [2] |
| 30 |
| 24 |
Notes for Table 19.2-24.10
| |
| Table 19.2-24.10 Required Conditions for Commercial/High-Density Residential/Mixed-Use District | |
|---|---|
| Project Standards | |
| None required |
| |
| 1 |
| 2 |
| [2] |
| 30 |
| 24 |
Notes for Table 19.2-24.10
| |
| Table 19.2-24.10 Required Conditions for Commercial/High-Density Residential/Mixed-Use District | |
|---|---|
| Project Standards | |
| None required |
| |
| 1 |
| 2 |
| [2] |
| 30 |
| 24 |
Notes for Table 19.2-24.10
| |
| Table 19.2-24.10 Required Conditions for Commercial/High-Density Residential/Mixed-Use District | |
|---|---|
| Project Standards | |
| None required |
| |
| 1 |
| 2 |
| [2] |
| 30 |
| 24 |
Notes for Table 19.2-24.10
| |
| Table 19.2-24.11 Required Conditions for Commercial/High-Density Residential/Mixed-Use District | |
|---|---|
| Building Standards | |
| |
| |
| 10, No Perimeter Landscaping required |
| No setback or Perimeter Landscaping required |
| |
| 15/A[4] |
| 40/C |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| None required |
| None required |
| None required |
| No maximum |
| |
| 3 stories |
| 8 stories |
| |
| Same as principal buildings |
Table 19.2-24.11
| |
| Table 19.2-24.11 Required Conditions for Commercial/High-Density Residential/Mixed-Use District | |
|---|---|
| Building Standards | |
| |
| |
| 10, No Perimeter Landscaping required |
| No setback or Perimeter Landscaping required |
| |
| 15/A[4] |
| 40/C |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| None required |
| None required |
| None required |
| No maximum |
| |
| 3 stories |
| 8 stories |
| |
| Same as principal buildings |
Table 19.2-24.11
| |
| Table 19.2-24.11 Required Conditions for Commercial/High-Density Residential/Mixed-Use District | |
|---|---|
| Building Standards | |
| |
| |
| 10, No Perimeter Landscaping required |
| No setback or Perimeter Landscaping required |
| |
| 15/A[4] |
| 40/C |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| None required |
| None required |
| None required |
| No maximum |
| |
| 3 stories |
| 8 stories |
| |
| Same as principal buildings |
Table 19.2-24.11
| |
| Table 19.2-24.11 Required Conditions for Commercial/High-Density Residential/Mixed-Use District | |
|---|---|
| Building Standards | |
| |
| |
| 10, No Perimeter Landscaping required |
| No setback or Perimeter Landscaping required |
| |
| 15/A[4] |
| 40/C |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| None required |
| None required |
| None required |
| No maximum |
| |
| 3 stories |
| 8 stories |
| |
| Same as principal buildings |
Table 19.2-24.11
| |
Purpose: pursuant to the Comprehensive Plan, this section:
| Table 19.2-25.1 Airport Overlay Zones | |
|---|---|
| Zone | Description |
| Airport zone | Horizontal zone centered about and above the runway, with the floor of the zone 387 feet above mean sea level. |
| Approach zone | Sloping zone that extends away from the runway ends along the extended runway centerline, with the floor set by the approach surfaces. The lower surface of the approach zone equals the runway end elevation. The surface of the zone slopes upward as it extends away from the runway. |
| Transitional zone | Sloping zone that fans away perpendicular to the runway centerline and approach surfaces, with the floor set by the transitional surfaces. |
| Conical zone | Sloping zone that circles around the periphery of, and outward from, the airport zone with the floor set by the conical surface. The lower surface of the conical zone touches the airport zone at an elevation of 387 feet above mean sea level and slopes upward and outward to an elevation of 587 feet above mean sea level. |
| Primary zone | Generally horizontal zone that is centered about the runway. The surface of the zone is the same elevation as the elevation of the nearest point of the runway centerline. |
| Table 19.2-25.1 Airport Overlay Zones | |
|---|---|
| Zone | Description |
| Airport zone | Horizontal zone centered about and above the runway, with the floor of the zone 387 feet above mean sea level. |
| Approach zone | Sloping zone that extends away from the runway ends along the extended runway centerline, with the floor set by the approach surfaces. The lower surface of the approach zone equals the runway end elevation. The surface of the zone slopes upward as it extends away from the runway. |
| Transitional zone | Sloping zone that fans away perpendicular to the runway centerline and approach surfaces, with the floor set by the transitional surfaces. |
| Conical zone | Sloping zone that circles around the periphery of, and outward from, the airport zone with the floor set by the conical surface. The lower surface of the conical zone touches the airport zone at an elevation of 387 feet above mean sea level and slopes upward and outward to an elevation of 587 feet above mean sea level. |
| Primary zone | Generally horizontal zone that is centered about the runway. The surface of the zone is the same elevation as the elevation of the nearest point of the runway centerline. |
| Table 19.2-25.1 Airport Overlay Zones | |
|---|---|
| Zone | Description |
| Airport zone | Horizontal zone centered about and above the runway, with the floor of the zone 387 feet above mean sea level. |
| Approach zone | Sloping zone that extends away from the runway ends along the extended runway centerline, with the floor set by the approach surfaces. The lower surface of the approach zone equals the runway end elevation. The surface of the zone slopes upward as it extends away from the runway. |
| Transitional zone | Sloping zone that fans away perpendicular to the runway centerline and approach surfaces, with the floor set by the transitional surfaces. |
| Conical zone | Sloping zone that circles around the periphery of, and outward from, the airport zone with the floor set by the conical surface. The lower surface of the conical zone touches the airport zone at an elevation of 387 feet above mean sea level and slopes upward and outward to an elevation of 587 feet above mean sea level. |
| Primary zone | Generally horizontal zone that is centered about the runway. The surface of the zone is the same elevation as the elevation of the nearest point of the runway centerline. |
| Table 19.2-25.1 Airport Overlay Zones | |
|---|---|
| Zone | Description |
| Airport zone | Horizontal zone centered about and above the runway, with the floor of the zone 387 feet above mean sea level. |
| Approach zone | Sloping zone that extends away from the runway ends along the extended runway centerline, with the floor set by the approach surfaces. The lower surface of the approach zone equals the runway end elevation. The surface of the zone slopes upward as it extends away from the runway. |
| Transitional zone | Sloping zone that fans away perpendicular to the runway centerline and approach surfaces, with the floor set by the transitional surfaces. |
| Conical zone | Sloping zone that circles around the periphery of, and outward from, the airport zone with the floor set by the conical surface. The lower surface of the conical zone touches the airport zone at an elevation of 387 feet above mean sea level and slopes upward and outward to an elevation of 587 feet above mean sea level. |
| Primary zone | Generally horizontal zone that is centered about the runway. The surface of the zone is the same elevation as the elevation of the nearest point of the runway centerline. |
Purpose: This Section protects and improves water quality in the Chesapeake Bay and its tributaries by requiring the use of effective conservation planning and pollution prevention practices when using and developing environmentally sensitive lands. This Section implements the Chesapeake Bay Preservation Act (Act) (Code of Virginia Title 62.1, Chapter 3.1, Article 2.5, § 62.1-44.15:67 et seq.). The two types of Chesapeake Bay Preservation Areas (CBPA) are Resource Protection Areas (RPA) and Resource Management Areas (RMA). RPAs serve an important water quality function by protecting County water bodies and providing a buffer adjacent to them. The buffer acts to filter runoff prior to entering water bodies. RMAs also include land types that have the potential to cause significant water quality degradation or for diminishing the functional value of the RPA if they are improperly used or developed. The entire County is designated as an RMA.
Purpose: The floodplain management regulations set forth in this Section are adopted pursuant to the authority set forth in Va. Code § 15.2-2280 and may be referred to as the floodplain management ordinance. The purpose of these provisions is to prevent loss of life and property, creation of hazards to health and safety, disruption of commercial and governmental services, extraordinary and unnecessary expenditure of public funds for flood protection and relief and impairment of the tax base by:
Floodway District. The following shall be prohibited in the floodway district: structures, substantial improvements, manufactured homes, fill or other development. The County shall not grant relief from this provision through any process, unless relief from this provision shall have first been approved by FEMA to the extent that the Director of Environmental Engineering determines that FEMA approval is required.
Zoning Districts
Purpose: This Chapter is enacted to promote and protect the health, safety and general welfare of the people of the County. It is the intention of the Board of Supervisors that the provisions of this Chapter will implement the purpose and intent of the Comprehensive Plan of the County by encouraging the most desirable use of the land for residential, recreational, agricultural, forestry, commercial, industrial, conservation, public service, floodplain, drainage, and other purposes; by encouraging the most appropriate use and occupancy of buildings; by protecting and improving the quality of the waters within and adjacent to the County; and by promoting good civic design and arrangement. The provisions of this Chapter provide reasonable standards with respect to the location, height, bulk, size of buildings, and other structures; yard areas, courts, off-street parking facilities and other open spaces; the use of buildings, structures; and land for trade, industry, business, residence, or other purposes.
Generally. The standards in the following overlays supersede the typical district standards identified in Article 2, Divisions 2, 3, and 4 and the development standards in Article 4 where applicable. Where the overlay does not have a standard or is silent, the County-wide standards shall apply.
Land Uses. The permitted by-right (P), permitted subject to restrictions (R), conditional (C), conditional use with additional guidance (C*), special exception (S), and prohibited uses are set out in the underlying zoning district (see Article 3, Uses).
The County is divided into the following zoning districts:
| Table 19.2-71 Zoning Districts | |||
|---|---|---|---|
| District | Symbol | Comprehensive Plan Category | Reference |
| Residential Districts | |||
| Agricultural | A | Rural Residential/Agricultural, Residential Agricultural | 19.2-8 |
| Rural Community | RC | Rural Residential/Agricultural, Residential Agricultural | 19.2-9 |
| Semi-Rural Neighborhood | SR | Residential Agricultural, Residential Neighborhood 1 | 19.2-10 |
| Suburban Community | SC | Phased Residential, Residential Neighborhood 2, and Residential Neighborhood 4 | 19.2-11 |
| Semi-Urban Neighborhood | SU | Residential Neighborhood 4, Residential Neighborhood 8 | 19.2-12 |
Transition Residential | TR | Residential Neighborhood 8, Residential Neighborhood 12 | 19.2-13 |
Urban Residential | UR | Neighborhood Mixed-Use, Community Mixed-Use, and Regional Mixed-Use | 19.2-14 |
Alternative Residential | AR | 19.2-15 | |
| Commercial and Mixed-Use Districts | |||
Neighborhood Business | NB | Light Business | 19.2-16 |
| Corridor Commercial | CC | Arterial Business | 19.2-17 |
Mixed-Use Center | MU | Neighborhood Mixed-Use, Community Mixed-Use, Regional Mixed-Use | 19.2-18 |
| Employment Districts | |||
| Employment Center | EC | Office/Light Production and Assembly (OLPA) | 19.2-19 |
Employment General | EG | Manufacturing and Processing | 19.2-20 |
Warehouse & Distribution | WD | Office/Light Production and Assembly (OLPA), Manufacturing and Processing | 19.2-21 |
| Overlay Districts | |||
| Village Overlay | VO | Specific Area Plans | 19.2-22 |
| Urban Corridor Overlay | UCO | Specific Area Plans | 19.2-23 |
| Roseland Zoning Overlay | RZO | Residential Neighborhood 2, Light Business, Residential Neighborhood 12, Regional Mixed Use, Office/Light Production and Assembly (OLPA) | 19.2-24 |
| Airport Overlays | AO | Chesterfield County Airport Operational and Runway Approach Areas | 19.2-25 |
| Chesapeake Bay Preservation Areas |
CBPA | 19.2-26 | |
| Floodplain Management Districts | F | 19.2-27 | |
| Table 19.2-71 Zoning Districts | |||
|---|---|---|---|
| District | Symbol | Comprehensive Plan Category | Reference |
| Residential Districts | |||
| Agricultural | A | Rural Residential/Agricultural, Residential Agricultural | 19.2-8 |
| Rural Community | RC | Rural Residential/Agricultural, Residential Agricultural | 19.2-9 |
| Semi-Rural Neighborhood | SR | Residential Agricultural, Residential Neighborhood 1 | 19.2-10 |
| Suburban Community | SC | Phased Residential, Residential Neighborhood 2, and Residential Neighborhood 4 | 19.2-11 |
| Semi-Urban Neighborhood | SU | Residential Neighborhood 4, Residential Neighborhood 8 | 19.2-12 |
Transition Residential | TR | Residential Neighborhood 8, Residential Neighborhood 12 | 19.2-13 |
Urban Residential | UR | Neighborhood Mixed-Use, Community Mixed-Use, and Regional Mixed-Use | 19.2-14 |
Alternative Residential | AR | 19.2-15 | |
| Commercial and Mixed-Use Districts | |||
Neighborhood Business | NB | Light Business | 19.2-16 |
| Corridor Commercial | CC | Arterial Business | 19.2-17 |
Mixed-Use Center | MU | Neighborhood Mixed-Use, Community Mixed-Use, Regional Mixed-Use | 19.2-18 |
| Employment Districts | |||
| Employment Center | EC | Office/Light Production and Assembly (OLPA) | 19.2-19 |
Employment General | EG | Manufacturing and Processing | 19.2-20 |
Warehouse & Distribution | WD | Office/Light Production and Assembly (OLPA), Manufacturing and Processing | 19.2-21 |
| Overlay Districts | |||
| Village Overlay | VO | Specific Area Plans | 19.2-22 |
| Urban Corridor Overlay | UCO | Specific Area Plans | 19.2-23 |
| Roseland Zoning Overlay | RZO | Residential Neighborhood 2, Light Business, Residential Neighborhood 12, Regional Mixed Use, Office/Light Production and Assembly (OLPA) | 19.2-24 |
| Airport Overlays | AO | Chesterfield County Airport Operational and Runway Approach Areas | 19.2-25 |
| Chesapeake Bay Preservation Areas |
CBPA | 19.2-26 | |
| Floodplain Management Districts | F | 19.2-27 | |
| Table 19.2-71 Zoning Districts | |||
|---|---|---|---|
| District | Symbol | Comprehensive Plan Category | Reference |
| Residential Districts | |||
| Agricultural | A | Rural Residential/Agricultural, Residential Agricultural | 19.2-8 |
| Rural Community | RC | Rural Residential/Agricultural, Residential Agricultural | 19.2-9 |
| Semi-Rural Neighborhood | SR | Residential Agricultural, Residential Neighborhood 1 | 19.2-10 |
| Suburban Community | SC | Phased Residential, Residential Neighborhood 2, and Residential Neighborhood 4 | 19.2-11 |
| Semi-Urban Neighborhood | SU | Residential Neighborhood 4, Residential Neighborhood 8 | 19.2-12 |
Transition Residential | TR | Residential Neighborhood 8, Residential Neighborhood 12 | 19.2-13 |
Urban Residential | UR | Neighborhood Mixed-Use, Community Mixed-Use, and Regional Mixed-Use | 19.2-14 |
Alternative Residential | AR | 19.2-15 | |
| Commercial and Mixed-Use Districts | |||
Neighborhood Business | NB | Light Business | 19.2-16 |
| Corridor Commercial | CC | Arterial Business | 19.2-17 |
Mixed-Use Center | MU | Neighborhood Mixed-Use, Community Mixed-Use, Regional Mixed-Use | 19.2-18 |
| Employment Districts | |||
| Employment Center | EC | Office/Light Production and Assembly (OLPA) | 19.2-19 |
Employment General | EG | Manufacturing and Processing | 19.2-20 |
Warehouse & Distribution | WD | Office/Light Production and Assembly (OLPA), Manufacturing and Processing | 19.2-21 |
| Overlay Districts | |||
| Village Overlay | VO | Specific Area Plans | 19.2-22 |
| Urban Corridor Overlay | UCO | Specific Area Plans | 19.2-23 |
| Roseland Zoning Overlay | RZO | Residential Neighborhood 2, Light Business, Residential Neighborhood 12, Regional Mixed Use, Office/Light Production and Assembly (OLPA) | 19.2-24 |
| Airport Overlays | AO | Chesterfield County Airport Operational and Runway Approach Areas | 19.2-25 |
| Chesapeake Bay Preservation Areas |
CBPA | 19.2-26 | |
| Floodplain Management Districts | F | 19.2-27 | |
| Table 19.2-71 Zoning Districts | |||
|---|---|---|---|
| District | Symbol | Comprehensive Plan Category | Reference |
| Residential Districts | |||
| Agricultural | A | Rural Residential/Agricultural, Residential Agricultural | 19.2-8 |
| Rural Community | RC | Rural Residential/Agricultural, Residential Agricultural | 19.2-9 |
| Semi-Rural Neighborhood | SR | Residential Agricultural, Residential Neighborhood 1 | 19.2-10 |
| Suburban Community | SC | Phased Residential, Residential Neighborhood 2, and Residential Neighborhood 4 | 19.2-11 |
| Semi-Urban Neighborhood | SU | Residential Neighborhood 4, Residential Neighborhood 8 | 19.2-12 |
Transition Residential | TR | Residential Neighborhood 8, Residential Neighborhood 12 | 19.2-13 |
Urban Residential | UR | Neighborhood Mixed-Use, Community Mixed-Use, and Regional Mixed-Use | 19.2-14 |
Alternative Residential | AR | 19.2-15 | |
| Commercial and Mixed-Use Districts | |||
Neighborhood Business | NB | Light Business | 19.2-16 |
| Corridor Commercial | CC | Arterial Business | 19.2-17 |
Mixed-Use Center | MU | Neighborhood Mixed-Use, Community Mixed-Use, Regional Mixed-Use | 19.2-18 |
| Employment Districts | |||
| Employment Center | EC | Office/Light Production and Assembly (OLPA) | 19.2-19 |
Employment General | EG | Manufacturing and Processing | 19.2-20 |
Warehouse & Distribution | WD | Office/Light Production and Assembly (OLPA), Manufacturing and Processing | 19.2-21 |
| Overlay Districts | |||
| Village Overlay | VO | Specific Area Plans | 19.2-22 |
| Urban Corridor Overlay | UCO | Specific Area Plans | 19.2-23 |
| Roseland Zoning Overlay | RZO | Residential Neighborhood 2, Light Business, Residential Neighborhood 12, Regional Mixed Use, Office/Light Production and Assembly (OLPA) | 19.2-24 |
| Airport Overlays | AO | Chesterfield County Airport Operational and Runway Approach Areas | 19.2-25 |
| Chesapeake Bay Preservation Areas |
CBPA | 19.2-26 | |
| Floodplain Management Districts | F | 19.2-27 | |
Purpose. The Agricultural (A) District provides land areas for large lot single-family dwellings as well as forest and farmland including agricultural and silvicultural operations and ancillary uses that contribute to and complement the natural environment and rural character. The role of this district is to preserve natural areas, water resources, wildlife habitat, and open spaces while protecting the rural economy of the County and preventing the encroachment of premature and incompatible land uses.
| Table 19.2-8.1, Agricultural (A) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||||||
| Key | Development | Base | Option 1 | |||||
| Neighborhood Type | Lots recorded: | Non-Residential | ||||||
| After 02.27.01 | 05.26.88 thru 02.27.01 | Before 05.26.88 | ||||||
| Lot Standards | ||||||||
| A | Lot Area (min) [1] [2] | 5.0 ac | 1.0 ac | 15,000 sf. | 1.0 ac | |||
| B | Lot Width (min) [3] | 150' | 150' | 100' | 150' | |||
| C | Road Frontage (min) [4] [5] | 250' | 50' | 50' | 50' | |||
| D | Building Coverage (max) | 20% | 20% | 30% | 20% | |||
| Building Standards | ||||||||
| Principal Building Placement [6] [7] | ||||||||
| E | Front Setback (min) | 150' | 150' [8] | 100' [9] | [13] | |||
| F | Side Setback (min) | 40' | 40' | 15' /10' [10] | [13] | |||
| G | Corner Side Setback (min) - Through Lot back-to-back with another corner lot or backing to open space or common areas - Other |
40'
75' |
40'
75' |
20'
35' [11] |
[13]
[13] | |||
| H | Rear Setback (min) - Non-Through Lot - Through Lot |
50' 150' |
50' 150' [7] |
25' 100' [8] | [13] [13] | |||
| Accessory Building Placement | ||||||||
| I | Front Setback (min) | Lesser of 1/2 the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | 40' | 40' | 15' | [13] | |||
| K | Corner Side Setback (min) - Buildings Less Than 15' in Height - Buildings 15' or Greater in Height | 150'
150' | 150'
150' | [12]
[12] | [13] | |||
| L | Rear Setback (min) - Standard Lot - Through Lot |
25' 30' |
25' 30' |
12.5' 30' | [13] | |||
| Accessory Building Placement for Structures under 15' in height | ||||||||
| Front Setback (min) | Lesser of 1/2 the average depth of the lot or 80' | |||||||
| Side Setback (min) | 20' | 20' | 7.5' | [13] | ||||
| Corner Side Setback (min) | 150' | 150' | [12] | [13] | ||||
Rear Setback (min) - Standard Lot - Through Lot |
10' 30' |
10' 30' |
10' 30' | [13] | ||||
| Building Height | ||||||||
| M | Principal Building height (max) | 45' | 45' | 45' | 45' | |||
Farm Structure Height, Village Overlay (max) Farm Structure Height, Other Areas (max) | 45' 50' | 45' 50' | 45' 50' | 45' 50' | ||||
| Parking | ||||||||
| N | Parking Lot Setback | -- | -- | -- | 50' | |||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Not Required, unless required by County Code Sec. 18-60. | Not Required, unless required by County Code Sec. 18-60. | Not Required, unless required by County Code 18-60. | Not Required, unless required by County Code 18-60. | |||
Notes:
| ||||||||
| Table 19.2-8.1, Agricultural (A) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||||||
| Key | Development | Base | Option 1 | |||||
| Neighborhood Type | Lots recorded: | Non-Residential | ||||||
| After 02.27.01 | 05.26.88 thru 02.27.01 | Before 05.26.88 | ||||||
| Lot Standards | ||||||||
| A | Lot Area (min) [1] [2] | 5.0 ac | 1.0 ac | 15,000 sf. | 1.0 ac | |||
| B | Lot Width (min) [3] | 150' | 150' | 100' | 150' | |||
| C | Road Frontage (min) [4] [5] | 250' | 50' | 50' | 50' | |||
| D | Building Coverage (max) | 20% | 20% | 30% | 20% | |||
| Building Standards | ||||||||
| Principal Building Placement [6] [7] | ||||||||
| E | Front Setback (min) | 150' | 150' [8] | 100' [9] | [13] | |||
| F | Side Setback (min) | 40' | 40' | 15' /10' [10] | [13] | |||
| G | Corner Side Setback (min) - Through Lot back-to-back with another corner lot or backing to open space or common areas - Other |
40'
75' |
40'
75' |
20'
35' [11] |
[13]
[13] | |||
| H | Rear Setback (min) - Non-Through Lot - Through Lot |
50' 150' |
50' 150' [7] |
25' 100' [8] | [13] [13] | |||
| Accessory Building Placement | ||||||||
| I | Front Setback (min) | Lesser of 1/2 the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | 40' | 40' | 15' | [13] | |||
| K | Corner Side Setback (min) - Buildings Less Than 15' in Height - Buildings 15' or Greater in Height | 150'
150' | 150'
150' | [12]
[12] | [13] | |||
| L | Rear Setback (min) - Standard Lot - Through Lot |
25' 30' |
25' 30' |
12.5' 30' | [13] | |||
| Accessory Building Placement for Structures under 15' in height | ||||||||
| Front Setback (min) | Lesser of 1/2 the average depth of the lot or 80' | |||||||
| Side Setback (min) | 20' | 20' | 7.5' | [13] | ||||
| Corner Side Setback (min) | 150' | 150' | [12] | [13] | ||||
Rear Setback (min) - Standard Lot - Through Lot |
10' 30' |
10' 30' |
10' 30' | [13] | ||||
| Building Height | ||||||||
| M | Principal Building height (max) | 45' | 45' | 45' | 45' | |||
Farm Structure Height, Village Overlay (max) Farm Structure Height, Other Areas (max) | 45' 50' | 45' 50' | 45' 50' | 45' 50' | ||||
| Parking | ||||||||
| N | Parking Lot Setback | -- | -- | -- | 50' | |||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Not Required, unless required by County Code Sec. 18-60. | Not Required, unless required by County Code Sec. 18-60. | Not Required, unless required by County Code 18-60. | Not Required, unless required by County Code 18-60. | |||
Notes:
| ||||||||
| Table 19.2-8.1, Agricultural (A) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||||||
| Key | Development | Base | Option 1 | |||||
| Neighborhood Type | Lots recorded: | Non-Residential | ||||||
| After 02.27.01 | 05.26.88 thru 02.27.01 | Before 05.26.88 | ||||||
| Lot Standards | ||||||||
| A | Lot Area (min) [1] [2] | 5.0 ac | 1.0 ac | 15,000 sf. | 1.0 ac | |||
| B | Lot Width (min) [3] | 150' | 150' | 100' | 150' | |||
| C | Road Frontage (min) [4] [5] | 250' | 50' | 50' | 50' | |||
| D | Building Coverage (max) | 20% | 20% | 30% | 20% | |||
| Building Standards | ||||||||
| Principal Building Placement [6] [7] | ||||||||
| E | Front Setback (min) | 150' | 150' [8] | 100' [9] | [13] | |||
| F | Side Setback (min) | 40' | 40' | 15' /10' [10] | [13] | |||
| G | Corner Side Setback (min) - Through Lot back-to-back with another corner lot or backing to open space or common areas - Other |
40'
75' |
40'
75' |
20'
35' [11] |
[13]
[13] | |||
| H | Rear Setback (min) - Non-Through Lot - Through Lot |
50' 150' |
50' 150' [7] |
25' 100' [8] | [13] [13] | |||
| Accessory Building Placement | ||||||||
| I | Front Setback (min) | Lesser of 1/2 the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | 40' | 40' | 15' | [13] | |||
| K | Corner Side Setback (min) - Buildings Less Than 15' in Height - Buildings 15' or Greater in Height | 150'
150' | 150'
150' | [12]
[12] | [13] | |||
| L | Rear Setback (min) - Standard Lot - Through Lot |
25' 30' |
25' 30' |
12.5' 30' | [13] | |||
| Accessory Building Placement for Structures under 15' in height | ||||||||
| Front Setback (min) | Lesser of 1/2 the average depth of the lot or 80' | |||||||
| Side Setback (min) | 20' | 20' | 7.5' | [13] | ||||
| Corner Side Setback (min) | 150' | 150' | [12] | [13] | ||||
Rear Setback (min) - Standard Lot - Through Lot |
10' 30' |
10' 30' |
10' 30' | [13] | ||||
| Building Height | ||||||||
| M | Principal Building height (max) | 45' | 45' | 45' | 45' | |||
Farm Structure Height, Village Overlay (max) Farm Structure Height, Other Areas (max) | 45' 50' | 45' 50' | 45' 50' | 45' 50' | ||||
| Parking | ||||||||
| N | Parking Lot Setback | -- | -- | -- | 50' | |||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Not Required, unless required by County Code Sec. 18-60. | Not Required, unless required by County Code Sec. 18-60. | Not Required, unless required by County Code 18-60. | Not Required, unless required by County Code 18-60. | |||
Notes:
| ||||||||
| Table 19.2-8.1, Agricultural (A) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||||||
| Key | Development | Base | Option 1 | |||||
| Neighborhood Type | Lots recorded: | Non-Residential | ||||||
| After 02.27.01 | 05.26.88 thru 02.27.01 | Before 05.26.88 | ||||||
| Lot Standards | ||||||||
| A | Lot Area (min) [1] [2] | 5.0 ac | 1.0 ac | 15,000 sf. | 1.0 ac | |||
| B | Lot Width (min) [3] | 150' | 150' | 100' | 150' | |||
| C | Road Frontage (min) [4] [5] | 250' | 50' | 50' | 50' | |||
| D | Building Coverage (max) | 20% | 20% | 30% | 20% | |||
| Building Standards | ||||||||
| Principal Building Placement [6] [7] | ||||||||
| E | Front Setback (min) | 150' | 150' [8] | 100' [9] | [13] | |||
| F | Side Setback (min) | 40' | 40' | 15' /10' [10] | [13] | |||
| G | Corner Side Setback (min) - Through Lot back-to-back with another corner lot or backing to open space or common areas - Other |
40'
75' |
40'
75' |
20'
35' [11] |
[13]
[13] | |||
| H | Rear Setback (min) - Non-Through Lot - Through Lot |
50' 150' |
50' 150' [7] |
25' 100' [8] | [13] [13] | |||
| Accessory Building Placement | ||||||||
| I | Front Setback (min) | Lesser of 1/2 the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | 40' | 40' | 15' | [13] | |||
| K | Corner Side Setback (min) - Buildings Less Than 15' in Height - Buildings 15' or Greater in Height | 150'
150' | 150'
150' | [12]
[12] | [13] | |||
| L | Rear Setback (min) - Standard Lot - Through Lot |
25' 30' |
25' 30' |
12.5' 30' | [13] | |||
| Accessory Building Placement for Structures under 15' in height | ||||||||
| Front Setback (min) | Lesser of 1/2 the average depth of the lot or 80' | |||||||
| Side Setback (min) | 20' | 20' | 7.5' | [13] | ||||
| Corner Side Setback (min) | 150' | 150' | [12] | [13] | ||||
Rear Setback (min) - Standard Lot - Through Lot |
10' 30' |
10' 30' |
10' 30' | [13] | ||||
| Building Height | ||||||||
| M | Principal Building height (max) | 45' | 45' | 45' | 45' | |||
Farm Structure Height, Village Overlay (max) Farm Structure Height, Other Areas (max) | 45' 50' | 45' 50' | 45' 50' | 45' 50' | ||||
| Parking | ||||||||
| N | Parking Lot Setback | -- | -- | -- | 50' | |||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Not Required, unless required by County Code Sec. 18-60. | Not Required, unless required by County Code Sec. 18-60. | Not Required, unless required by County Code 18-60. | Not Required, unless required by County Code 18-60. | |||
Notes:
| ||||||||
Table 19.2-8.3, Principal Building Placement (where zoning approval has been granted to allow use for dwelling purposes or a manufactured home without public road frontage) [1] [2] | |
|---|---|
| Development | Standard |
| Front Setback (min) [3] | 40' |
| Side Setback (min) | 15' |
| Rear Setback (min) | 25' |
Notes:
| |
Table 19.2-8.3, Principal Building Placement (where zoning approval has been granted to allow use for dwelling purposes or a manufactured home without public road frontage) [1] [2] | |
|---|---|
| Development | Standard |
| Front Setback (min) [3] | 40' |
| Side Setback (min) | 15' |
| Rear Setback (min) | 25' |
Notes:
| |
Table 19.2-8.3, Principal Building Placement (where zoning approval has been granted to allow use for dwelling purposes or a manufactured home without public road frontage) [1] [2] | |
|---|---|
| Development | Standard |
| Front Setback (min) [3] | 40' |
| Side Setback (min) | 15' |
| Rear Setback (min) | 25' |
Notes:
| |
Table 19.2-8.3, Principal Building Placement (where zoning approval has been granted to allow use for dwelling purposes or a manufactured home without public road frontage) [1] [2] | |
|---|---|
| Development | Standard |
| Front Setback (min) [3] | 40' |
| Side Setback (min) | 15' |
| Rear Setback (min) | 25' |
Notes:
| |
| Figure 19.2-8.1, A Illustrated Renderings |
|---|
| Base |
|
|
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-8.1, A Illustrated Renderings |
|---|
| Base |
|
|
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-8.1, A Illustrated Renderings |
|---|
| Base |
|
|
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-8.1, A Illustrated Renderings |
|---|
| Base |
|
|
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Provisions Related to the A District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Dimensional Standards | Sec. 19.2-37 |
| Landscaping and Screening | Sec. 19.2-41 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
(ZO-2025-002, Relative to Auto Sales, Required Utility Connections, and Site Plans, adopted 12/17/2025, effective 01/01/2026)
Purpose. The Rural Community (RC) District provides for residential development on minimum five acre lots. The role of the RC District is to provide a large lot subdivision development option served by new or existing public roads in the rural areas of the County with limited agricultural related uses.
| Table 19.2-9.1, Rural Community (RC) Lot and Building Standards | ||||
|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||
| Key | Development | Base | ||
| Neighborhood Type | Single-Family | |||
| -- | Amenity Space (min) | -- | ||
| Lot Standards | ||||
| A | Lot Area (min) | 5.0 ac | ||
| B | Lot Width (min) | 150' | ||
| C | Road Frontage (min) | 250' [1] | ||
| D | Building Coverage (max) | 20% | ||
| Building Standards | ||||
| Principal Building Placement [2] | ||||
| E | Front Setback (min) | 150' | ||
| F | Side Setback (min) | 40' | ||
| G | Corner Side Setback (min) - Through Lot, Lot Back-to-Back, or Lot Backing to Amenity Space - Other |
40' 75' | ||
| H | Rear Setback (min) - Non-Through Lot - Through Lot |
50' 150' | ||
| Accessory Building Placement | ||||
| I | Front Setback (min) | 100' | ||
| J | Side Setback (min) | 40' | ||
| K | Corner Side Setback (min) | 150' | ||
Rear Setback (min) - Standard Lot, 15' or Greater in Height - Through Lot, 15' or Greater in Height | 25' 30' | |||
| L | Accessory Building Placement for Structures Under 15' in Height | |||
| Front Setback (min) | 100' | |||
| Side Setback (min) | 20' | |||
| Corner Side Setback (min) | 150' | |||
Rear Setback - Standard Lot - Through Lot |
10' 30' | |||
| Principal & Accessory Building Height | ||||
| M | Height (max) | 45' | ||
| Utilities | ||||
Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Not required, unless required by County Code Sec. 18-60. | |||
Notes:
| ||||
| Table 19.2-9.1, Rural Community (RC) Lot and Building Standards | ||||
|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||
| Key | Development | Base | ||
| Neighborhood Type | Single-Family | |||
| -- | Amenity Space (min) | -- | ||
| Lot Standards | ||||
| A | Lot Area (min) | 5.0 ac | ||
| B | Lot Width (min) | 150' | ||
| C | Road Frontage (min) | 250' [1] | ||
| D | Building Coverage (max) | 20% | ||
| Building Standards | ||||
| Principal Building Placement [2] | ||||
| E | Front Setback (min) | 150' | ||
| F | Side Setback (min) | 40' | ||
| G | Corner Side Setback (min) - Through Lot, Lot Back-to-Back, or Lot Backing to Amenity Space - Other |
40' 75' | ||
| H | Rear Setback (min) - Non-Through Lot - Through Lot |
50' 150' | ||
| Accessory Building Placement | ||||
| I | Front Setback (min) | 100' | ||
| J | Side Setback (min) | 40' | ||
| K | Corner Side Setback (min) | 150' | ||
Rear Setback (min) - Standard Lot, 15' or Greater in Height - Through Lot, 15' or Greater in Height | 25' 30' | |||
| L | Accessory Building Placement for Structures Under 15' in Height | |||
| Front Setback (min) | 100' | |||
| Side Setback (min) | 20' | |||
| Corner Side Setback (min) | 150' | |||
Rear Setback - Standard Lot - Through Lot |
10' 30' | |||
| Principal & Accessory Building Height | ||||
| M | Height (max) | 45' | ||
| Utilities | ||||
Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Not required, unless required by County Code Sec. 18-60. | |||
Notes:
| ||||
| Table 19.2-9.1, Rural Community (RC) Lot and Building Standards | ||||
|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||
| Key | Development | Base | ||
| Neighborhood Type | Single-Family | |||
| -- | Amenity Space (min) | -- | ||
| Lot Standards | ||||
| A | Lot Area (min) | 5.0 ac | ||
| B | Lot Width (min) | 150' | ||
| C | Road Frontage (min) | 250' [1] | ||
| D | Building Coverage (max) | 20% | ||
| Building Standards | ||||
| Principal Building Placement [2] | ||||
| E | Front Setback (min) | 150' | ||
| F | Side Setback (min) | 40' | ||
| G | Corner Side Setback (min) - Through Lot, Lot Back-to-Back, or Lot Backing to Amenity Space - Other |
40' 75' | ||
| H | Rear Setback (min) - Non-Through Lot - Through Lot |
50' 150' | ||
| Accessory Building Placement | ||||
| I | Front Setback (min) | 100' | ||
| J | Side Setback (min) | 40' | ||
| K | Corner Side Setback (min) | 150' | ||
Rear Setback (min) - Standard Lot, 15' or Greater in Height - Through Lot, 15' or Greater in Height | 25' 30' | |||
| L | Accessory Building Placement for Structures Under 15' in Height | |||
| Front Setback (min) | 100' | |||
| Side Setback (min) | 20' | |||
| Corner Side Setback (min) | 150' | |||
Rear Setback - Standard Lot - Through Lot |
10' 30' | |||
| Principal & Accessory Building Height | ||||
| M | Height (max) | 45' | ||
| Utilities | ||||
Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Not required, unless required by County Code Sec. 18-60. | |||
Notes:
| ||||
| Table 19.2-9.1, Rural Community (RC) Lot and Building Standards | ||||
|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||
| Key | Development | Base | ||
| Neighborhood Type | Single-Family | |||
| -- | Amenity Space (min) | -- | ||
| Lot Standards | ||||
| A | Lot Area (min) | 5.0 ac | ||
| B | Lot Width (min) | 150' | ||
| C | Road Frontage (min) | 250' [1] | ||
| D | Building Coverage (max) | 20% | ||
| Building Standards | ||||
| Principal Building Placement [2] | ||||
| E | Front Setback (min) | 150' | ||
| F | Side Setback (min) | 40' | ||
| G | Corner Side Setback (min) - Through Lot, Lot Back-to-Back, or Lot Backing to Amenity Space - Other |
40' 75' | ||
| H | Rear Setback (min) - Non-Through Lot - Through Lot |
50' 150' | ||
| Accessory Building Placement | ||||
| I | Front Setback (min) | 100' | ||
| J | Side Setback (min) | 40' | ||
| K | Corner Side Setback (min) | 150' | ||
Rear Setback (min) - Standard Lot, 15' or Greater in Height - Through Lot, 15' or Greater in Height | 25' 30' | |||
| L | Accessory Building Placement for Structures Under 15' in Height | |||
| Front Setback (min) | 100' | |||
| Side Setback (min) | 20' | |||
| Corner Side Setback (min) | 150' | |||
Rear Setback - Standard Lot - Through Lot |
10' 30' | |||
| Principal & Accessory Building Height | ||||
| M | Height (max) | 45' | ||
| Utilities | ||||
Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Not required, unless required by County Code Sec. 18-60. | |||
Notes:
| ||||
| Figure 19.2-9.1, RC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Figure 19.2-9.1, RC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Figure 19.2-9.1, RC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Figure 19.2-9.1, RC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Provisions Related to the RC District | |
|---|---|
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Dimensional Standards | Sec. 19.2-37 |
| Landscaping and Screening | Sec. 19.2-41 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
| Provisions Related to the RC District | |
|---|---|
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Dimensional Standards | Sec. 19.2-37 |
| Landscaping and Screening | Sec. 19.2-41 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
| Provisions Related to the RC District | |
|---|---|
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Dimensional Standards | Sec. 19.2-37 |
| Landscaping and Screening | Sec. 19.2-41 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
| Provisions Related to the RC District | |
|---|---|
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Dimensional Standards | Sec. 19.2-37 |
| Landscaping and Screening | Sec. 19.2-41 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
(ZO-2025-002, Relative to Auto Sales, Required Utility Connections, and Site Plans, adopted 12/17/2025, effective 01/01/2026)
Purpose. The Semi-Rural Neighborhood (SR) District provides for residential development on larger lot sizes ranging from two acres to half-acre. The role of the SR District is to transition from the rural areas to developing areas of the County by encouraging developments that incorporate environmental features and green areas as key components.
| Table 19.2-10.1, Semi-Rural Neighborhood (SR) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf = square feet ' = feet | ||||||||
| Key | Development | Base | Option 1 | Option 2 | ||||
| Neighborhood Type | Single-Family | Single-Family | Single-Family | |||||
| -- | Amenity Space (min) | -- | -- | -- | ||||
| Lot Standards | ||||||||
| A | Lot Area (min) [1] | 87,120 sf. | 40,000 sf. | 21,780 sf. | ||||
| B | Lot Width (min) | 150' | 150' | 120' | ||||
| C | Road Frontage (min) - Cul-de-sac or Loop Road - Other Road |
30' 50' |
30' 50' |
30' 50' | ||||
| D | Building Coverage (max) | 20% | 20% | 25% | ||||
| Building Standards | ||||||||
| Principal Building Placement [2] | ||||||||
| E | Front Setback (min) [3] - Street - Cul-de-sac |
75' 25' |
60' 25' |
50' 25' | ||||
| F | Side Setback (min) | 30' | 20' | 15' | ||||
| G | Corner Side Setback (min) - Through Lot, Lot Back-to-Back or Lot Backing to Amenity Space - Other |
30' 75' |
30' 55' |
25' 45' | ||||
| H | Rear Setback (min) - Non-Through Lot - Through Lot |
50' 75' |
50' 60' |
40' 50' | ||||
| Accessory Building Placement for Structures 15' in Height or Greater, Not to Exceed 30' in Height | ||||||||
| I | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | Same as side setback of the principal building placement | ||||||
| K | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| L | Rear Setback (min) | Half of the rear setback of the principal building placement | ||||||
| Accessory Building Placement for Structures Under 15' in Height | ||||||||
| M | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| N | Side Setback (min) | Half of the side setback of the principal building placement | ||||||
| O | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| P | Rear Setback (min) - Non-through Lot - Through Lot |
10' 30' | ||||||
| Principal Building Height | ||||||||
| Q | Height (max) | 45' | 45' | 45' | ||||
| Utilities | ||||||||
Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Permitted only if approved by the Director of Utilities, or required by County Code Sec. 18-60. |
Water Required unless approved for an exception by County Code Sec. 18-61; Wastewater Not Required, unless required by County Code Sec. 18-60. |
Required, unless approved for an exception by County Code Sec. 18-61.
| |||||
Notes:
| ||||||||
| Table 19.2-10.1, Semi-Rural Neighborhood (SR) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf = square feet ' = feet | ||||||||
| Key | Development | Base | Option 1 | Option 2 | ||||
| Neighborhood Type | Single-Family | Single-Family | Single-Family | |||||
| -- | Amenity Space (min) | -- | -- | -- | ||||
| Lot Standards | ||||||||
| A | Lot Area (min) [1] | 87,120 sf. | 40,000 sf. | 21,780 sf. | ||||
| B | Lot Width (min) | 150' | 150' | 120' | ||||
| C | Road Frontage (min) - Cul-de-sac or Loop Road - Other Road |
30' 50' |
30' 50' |
30' 50' | ||||
| D | Building Coverage (max) | 20% | 20% | 25% | ||||
| Building Standards | ||||||||
| Principal Building Placement [2] | ||||||||
| E | Front Setback (min) [3] - Street - Cul-de-sac |
75' 25' |
60' 25' |
50' 25' | ||||
| F | Side Setback (min) | 30' | 20' | 15' | ||||
| G | Corner Side Setback (min) - Through Lot, Lot Back-to-Back or Lot Backing to Amenity Space - Other |
30' 75' |
30' 55' |
25' 45' | ||||
| H | Rear Setback (min) - Non-Through Lot - Through Lot |
50' 75' |
50' 60' |
40' 50' | ||||
| Accessory Building Placement for Structures 15' in Height or Greater, Not to Exceed 30' in Height | ||||||||
| I | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | Same as side setback of the principal building placement | ||||||
| K | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| L | Rear Setback (min) | Half of the rear setback of the principal building placement | ||||||
| Accessory Building Placement for Structures Under 15' in Height | ||||||||
| M | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| N | Side Setback (min) | Half of the side setback of the principal building placement | ||||||
| O | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| P | Rear Setback (min) - Non-through Lot - Through Lot |
10' 30' | ||||||
| Principal Building Height | ||||||||
| Q | Height (max) | 45' | 45' | 45' | ||||
| Utilities | ||||||||
Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Permitted only if approved by the Director of Utilities, or required by County Code Sec. 18-60. |
Water Required unless approved for an exception by County Code Sec. 18-61; Wastewater Not Required, unless required by County Code Sec. 18-60. |
Required, unless approved for an exception by County Code Sec. 18-61.
| |||||
Notes:
| ||||||||
| Table 19.2-10.1, Semi-Rural Neighborhood (SR) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf = square feet ' = feet | ||||||||
| Key | Development | Base | Option 1 | Option 2 | ||||
| Neighborhood Type | Single-Family | Single-Family | Single-Family | |||||
| -- | Amenity Space (min) | -- | -- | -- | ||||
| Lot Standards | ||||||||
| A | Lot Area (min) [1] | 87,120 sf. | 40,000 sf. | 21,780 sf. | ||||
| B | Lot Width (min) | 150' | 150' | 120' | ||||
| C | Road Frontage (min) - Cul-de-sac or Loop Road - Other Road |
30' 50' |
30' 50' |
30' 50' | ||||
| D | Building Coverage (max) | 20% | 20% | 25% | ||||
| Building Standards | ||||||||
| Principal Building Placement [2] | ||||||||
| E | Front Setback (min) [3] - Street - Cul-de-sac |
75' 25' |
60' 25' |
50' 25' | ||||
| F | Side Setback (min) | 30' | 20' | 15' | ||||
| G | Corner Side Setback (min) - Through Lot, Lot Back-to-Back or Lot Backing to Amenity Space - Other |
30' 75' |
30' 55' |
25' 45' | ||||
| H | Rear Setback (min) - Non-Through Lot - Through Lot |
50' 75' |
50' 60' |
40' 50' | ||||
| Accessory Building Placement for Structures 15' in Height or Greater, Not to Exceed 30' in Height | ||||||||
| I | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | Same as side setback of the principal building placement | ||||||
| K | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| L | Rear Setback (min) | Half of the rear setback of the principal building placement | ||||||
| Accessory Building Placement for Structures Under 15' in Height | ||||||||
| M | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| N | Side Setback (min) | Half of the side setback of the principal building placement | ||||||
| O | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| P | Rear Setback (min) - Non-through Lot - Through Lot |
10' 30' | ||||||
| Principal Building Height | ||||||||
| Q | Height (max) | 45' | 45' | 45' | ||||
| Utilities | ||||||||
Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Permitted only if approved by the Director of Utilities, or required by County Code Sec. 18-60. |
Water Required unless approved for an exception by County Code Sec. 18-61; Wastewater Not Required, unless required by County Code Sec. 18-60. |
Required, unless approved for an exception by County Code Sec. 18-61.
| |||||
Notes:
| ||||||||
| Table 19.2-10.1, Semi-Rural Neighborhood (SR) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf = square feet ' = feet | ||||||||
| Key | Development | Base | Option 1 | Option 2 | ||||
| Neighborhood Type | Single-Family | Single-Family | Single-Family | |||||
| -- | Amenity Space (min) | -- | -- | -- | ||||
| Lot Standards | ||||||||
| A | Lot Area (min) [1] | 87,120 sf. | 40,000 sf. | 21,780 sf. | ||||
| B | Lot Width (min) | 150' | 150' | 120' | ||||
| C | Road Frontage (min) - Cul-de-sac or Loop Road - Other Road |
30' 50' |
30' 50' |
30' 50' | ||||
| D | Building Coverage (max) | 20% | 20% | 25% | ||||
| Building Standards | ||||||||
| Principal Building Placement [2] | ||||||||
| E | Front Setback (min) [3] - Street - Cul-de-sac |
75' 25' |
60' 25' |
50' 25' | ||||
| F | Side Setback (min) | 30' | 20' | 15' | ||||
| G | Corner Side Setback (min) - Through Lot, Lot Back-to-Back or Lot Backing to Amenity Space - Other |
30' 75' |
30' 55' |
25' 45' | ||||
| H | Rear Setback (min) - Non-Through Lot - Through Lot |
50' 75' |
50' 60' |
40' 50' | ||||
| Accessory Building Placement for Structures 15' in Height or Greater, Not to Exceed 30' in Height | ||||||||
| I | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | Same as side setback of the principal building placement | ||||||
| K | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| L | Rear Setback (min) | Half of the rear setback of the principal building placement | ||||||
| Accessory Building Placement for Structures Under 15' in Height | ||||||||
| M | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| N | Side Setback (min) | Half of the side setback of the principal building placement | ||||||
| O | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| P | Rear Setback (min) - Non-through Lot - Through Lot |
10' 30' | ||||||
| Principal Building Height | ||||||||
| Q | Height (max) | 45' | 45' | 45' | ||||
| Utilities | ||||||||
Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Permitted only if approved by the Director of Utilities, or required by County Code Sec. 18-60. |
Water Required unless approved for an exception by County Code Sec. 18-61; Wastewater Not Required, unless required by County Code Sec. 18-60. |
Required, unless approved for an exception by County Code Sec. 18-61.
| |||||
Notes:
| ||||||||
| Figure 19.2-10.1, SR Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-10.1, SR Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-10.1, SR Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-10.1, SR Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Provisions Related to the SR District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Dimensional Standards | Sec. 19.2-37 |
| Landscaping and Screening | Sec. 19.2-41 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
(ZO-2025-002, Relative to Auto Sales, Required Utility Connections, and Site Plans, adopted 12/17/2025, effective 01/01/2026)
Purpose. The Suburban Community (SC) District provides for quality single-family neighborhoods in the developing areas of the County and as infill opportunities within established areas of the County. Developments in the SC District should feature connectivity to employment centers, services, amenities, and other neighborhoods.
| Table 19.2-11.1, Suburban Community (SC) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre sf. = square feet ' = feet | ||||||||
| Key | Development | Base | Option 1 | Option 2 | ||||
| Neighborhood Type | Single-Family | Single-Family | Single-Family | |||||
| -- | Amenity Space (min) | 0% | 7.5% | 10% | ||||
| Strategic Amenity Space (min) | -- | 0.01 ac/du | 0.01 ac/du | |||||
| Lot Standards | ||||||||
| A | Lot Area (min) | 14,500 sf. | 11,000 sf. | 8,000 sf. | ||||
| B | Lot Width (min) | 100' | 90' | 75' | ||||
| C | Road Frontage (min) - Cul-de-sac or Loop Road - Other Road |
30' 50' |
30' 50' |
30' 50' | ||||
| D | Building Coverage (max) | 25% | 35% | 40% | ||||
| Building Standards | ||||||||
| Principal Building Placement [1] | ||||||||
| E | Front Setback (min) [2] - Street - Cul-de-sac |
30' 25' |
30' 25' |
30' 25' | ||||
| F | Side Setback (min) | 15' [3] | 10' | 7.5' | ||||
G
| Corner Side Setback (min) - Through Lot, Lot Back-to-Back or Lot Backing to Amenity Space - Other |
20' 35' |
20' 30' |
15' 25' | ||||
| H | Rear Setback (min) - Non-through Lot - Through Lot |
25' 40' |
25' 30' |
25' 30' | ||||
| Accessory Building Placement for Structures 15' in Height or Greater, Not to Exceed 30' | ||||||||
| I | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | Same as side setback of the principal building placement | ||||||
| K | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| L | Rear Setback (min) | Half of the rear setback of the principal building placement | ||||||
| Accessory Building Placement for Structures Under 15' in Height | ||||||||
| M | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| N | Side Setback (min) | Half of the side setback of the principal building placement | ||||||
| O | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| P | Rear Setback (min) - Non-through lot - Through lot |
30' | ||||||
| Principal Building Height | ||||||||
| Q | Height (max) | 45' | 45' | 45' | ||||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | ||||
Notes:
| ||||||||
| Table 19.2-11.1, Suburban Community (SC) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre sf. = square feet ' = feet | ||||||||
| Key | Development | Base | Option 1 | Option 2 | ||||
| Neighborhood Type | Single-Family | Single-Family | Single-Family | |||||
| -- | Amenity Space (min) | 0% | 7.5% | 10% | ||||
| Strategic Amenity Space (min) | -- | 0.01 ac/du | 0.01 ac/du | |||||
| Lot Standards | ||||||||
| A | Lot Area (min) | 14,500 sf. | 11,000 sf. | 8,000 sf. | ||||
| B | Lot Width (min) | 100' | 90' | 75' | ||||
| C | Road Frontage (min) - Cul-de-sac or Loop Road - Other Road |
30' 50' |
30' 50' |
30' 50' | ||||
| D | Building Coverage (max) | 25% | 35% | 40% | ||||
| Building Standards | ||||||||
| Principal Building Placement [1] | ||||||||
| E | Front Setback (min) [2] - Street - Cul-de-sac |
30' 25' |
30' 25' |
30' 25' | ||||
| F | Side Setback (min) | 15' [3] | 10' | 7.5' | ||||
G
| Corner Side Setback (min) - Through Lot, Lot Back-to-Back or Lot Backing to Amenity Space - Other |
20' 35' |
20' 30' |
15' 25' | ||||
| H | Rear Setback (min) - Non-through Lot - Through Lot |
25' 40' |
25' 30' |
25' 30' | ||||
| Accessory Building Placement for Structures 15' in Height or Greater, Not to Exceed 30' | ||||||||
| I | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | Same as side setback of the principal building placement | ||||||
| K | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| L | Rear Setback (min) | Half of the rear setback of the principal building placement | ||||||
| Accessory Building Placement for Structures Under 15' in Height | ||||||||
| M | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| N | Side Setback (min) | Half of the side setback of the principal building placement | ||||||
| O | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| P | Rear Setback (min) - Non-through lot - Through lot |
30' | ||||||
| Principal Building Height | ||||||||
| Q | Height (max) | 45' | 45' | 45' | ||||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | ||||
Notes:
| ||||||||
| Table 19.2-11.1, Suburban Community (SC) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre sf. = square feet ' = feet | ||||||||
| Key | Development | Base | Option 1 | Option 2 | ||||
| Neighborhood Type | Single-Family | Single-Family | Single-Family | |||||
| -- | Amenity Space (min) | 0% | 7.5% | 10% | ||||
| Strategic Amenity Space (min) | -- | 0.01 ac/du | 0.01 ac/du | |||||
| Lot Standards | ||||||||
| A | Lot Area (min) | 14,500 sf. | 11,000 sf. | 8,000 sf. | ||||
| B | Lot Width (min) | 100' | 90' | 75' | ||||
| C | Road Frontage (min) - Cul-de-sac or Loop Road - Other Road |
30' 50' |
30' 50' |
30' 50' | ||||
| D | Building Coverage (max) | 25% | 35% | 40% | ||||
| Building Standards | ||||||||
| Principal Building Placement [1] | ||||||||
| E | Front Setback (min) [2] - Street - Cul-de-sac |
30' 25' |
30' 25' |
30' 25' | ||||
| F | Side Setback (min) | 15' [3] | 10' | 7.5' | ||||
G
| Corner Side Setback (min) - Through Lot, Lot Back-to-Back or Lot Backing to Amenity Space - Other |
20' 35' |
20' 30' |
15' 25' | ||||
| H | Rear Setback (min) - Non-through Lot - Through Lot |
25' 40' |
25' 30' |
25' 30' | ||||
| Accessory Building Placement for Structures 15' in Height or Greater, Not to Exceed 30' | ||||||||
| I | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | Same as side setback of the principal building placement | ||||||
| K | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| L | Rear Setback (min) | Half of the rear setback of the principal building placement | ||||||
| Accessory Building Placement for Structures Under 15' in Height | ||||||||
| M | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| N | Side Setback (min) | Half of the side setback of the principal building placement | ||||||
| O | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| P | Rear Setback (min) - Non-through lot - Through lot |
30' | ||||||
| Principal Building Height | ||||||||
| Q | Height (max) | 45' | 45' | 45' | ||||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | ||||
Notes:
| ||||||||
| Table 19.2-11.1, Suburban Community (SC) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre sf. = square feet ' = feet | ||||||||
| Key | Development | Base | Option 1 | Option 2 | ||||
| Neighborhood Type | Single-Family | Single-Family | Single-Family | |||||
| -- | Amenity Space (min) | 0% | 7.5% | 10% | ||||
| Strategic Amenity Space (min) | -- | 0.01 ac/du | 0.01 ac/du | |||||
| Lot Standards | ||||||||
| A | Lot Area (min) | 14,500 sf. | 11,000 sf. | 8,000 sf. | ||||
| B | Lot Width (min) | 100' | 90' | 75' | ||||
| C | Road Frontage (min) - Cul-de-sac or Loop Road - Other Road |
30' 50' |
30' 50' |
30' 50' | ||||
| D | Building Coverage (max) | 25% | 35% | 40% | ||||
| Building Standards | ||||||||
| Principal Building Placement [1] | ||||||||
| E | Front Setback (min) [2] - Street - Cul-de-sac |
30' 25' |
30' 25' |
30' 25' | ||||
| F | Side Setback (min) | 15' [3] | 10' | 7.5' | ||||
G
| Corner Side Setback (min) - Through Lot, Lot Back-to-Back or Lot Backing to Amenity Space - Other |
20' 35' |
20' 30' |
15' 25' | ||||
| H | Rear Setback (min) - Non-through Lot - Through Lot |
25' 40' |
25' 30' |
25' 30' | ||||
| Accessory Building Placement for Structures 15' in Height or Greater, Not to Exceed 30' | ||||||||
| I | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | Same as side setback of the principal building placement | ||||||
| K | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| L | Rear Setback (min) | Half of the rear setback of the principal building placement | ||||||
| Accessory Building Placement for Structures Under 15' in Height | ||||||||
| M | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| N | Side Setback (min) | Half of the side setback of the principal building placement | ||||||
| O | Corner Side Setback (min) | Same as front setback of the principal building placement | ||||||
| P | Rear Setback (min) - Non-through lot - Through lot |
30' | ||||||
| Principal Building Height | ||||||||
| Q | Height (max) | 45' | 45' | 45' | ||||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | ||||
Notes:
| ||||||||
| Figure 19.2-11.1, SC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-11.1, SC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-11.1, SC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-11.1, SC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Provisions Related to the SC District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Amenity Space | Sec. 19.2-34 |
| Dimension Standards | Sec. 19.2-37 |
| Landscaping and Screening | Sec. 19.2-41 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
(ZO-2025-002, Relative to Auto Sales, Required Utility Connections, and Site Plans, adopted 12/17/2025, effective 01/01/2026)
Purpose. The Semi-Urban Neighborhood (SU) District provides for single-family dwellings on smaller lots. The role of the SU District is to provide a transition from corridors and more intensely developed areas to single-family neighborhoods and may be appropriate in areas where environmental constraints make achieving Comprehensive Plan densities difficult. Developments in the SU District are encouraged to integrate affordable housing with market-rate development where appropriate.
| Table 19.2-12.1, Semi-Urban Neighborhood (SU) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||||||
| Development | Base | Option 1 | Option 2 | |||||
| Key | Neighborhood Type | Single-Family | Single-Family | Single-Family | ||||
| -- | Amenity Space (min) [1] | 10% | 12.5% | 15% | ||||
| Strategic Amenity Space (min) | 0.01 ac/du | 0.01 ac/du | 0.01 ac/du | |||||
| Lot Standards | ||||||||
| A | Lot Area (min) | 7,500 sf. | 6,000 sf. | 4,500 sf. | ||||
| B | Lot Width (min) | 75' | 60' | 45' | ||||
| C | Road Frontage (min) [2] - Cul-de-sac or loop road - Other road |
25' 50' |
25' 40' |
25' 25' | ||||
| D | Building coverage (max) [1] | 40% | 50% | 60% | ||||
| Building Standards | ||||||||
| Principal Building Placement [3] | ||||||||
| E | Front Setback (min) [1] - Street - Cul-de-sac |
25' 25' |
25' 25' |
25' 25' | ||||
| F | Side Setback (min) | 7.5' | 5' | 5' | ||||
| G | Corner Side Setback (min) - Through Lot, Lot Back-to-Back or Lot Backing to Amenity Space - Other |
15' 25' |
10' 20' |
10' 20' | ||||
| H | Rear Setback (min) - Non-through lot - Through lot |
25' 30' |
20' 25' |
15' 20' | ||||
| Accessory Building Placement for Structures 15' in Height or greater, not to exceed 30' in height | ||||||||
| I | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | Same as side setback of the primary building placement | ||||||
| K | Corner Side Setback (min) | Same as the front setback of the primary building placement | ||||||
| L | Rear Setback (min) | Half of the rear setback of the primary building placement | ||||||
| Accessory Building Placement for Structures under 15' in height | ||||||||
| M | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| N | Side Setback (min) | 3.75' | ||||||
| O | Corner Side Setback (min) | Same as front setback of the primary building placement | ||||||
| P | Rear Setback (min) - Non-through lot - Through lot |
5' 30 | ||||||
| Building Height | ||||||||
| Q | Height (max) | 45' | 45' | 45' | ||||
| Access and Parking [4] | ||||||||
| R | Parking Location | On-street or on-site | On-street, on-site | On-street, or on-site | ||||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | ||||
Notes:
| ||||||||
| Table 19.2-12.1, Semi-Urban Neighborhood (SU) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||||||
| Development | Base | Option 1 | Option 2 | |||||
| Key | Neighborhood Type | Single-Family | Single-Family | Single-Family | ||||
| -- | Amenity Space (min) [1] | 10% | 12.5% | 15% | ||||
| Strategic Amenity Space (min) | 0.01 ac/du | 0.01 ac/du | 0.01 ac/du | |||||
| Lot Standards | ||||||||
| A | Lot Area (min) | 7,500 sf. | 6,000 sf. | 4,500 sf. | ||||
| B | Lot Width (min) | 75' | 60' | 45' | ||||
| C | Road Frontage (min) [2] - Cul-de-sac or loop road - Other road |
25' 50' |
25' 40' |
25' 25' | ||||
| D | Building coverage (max) [1] | 40% | 50% | 60% | ||||
| Building Standards | ||||||||
| Principal Building Placement [3] | ||||||||
| E | Front Setback (min) [1] - Street - Cul-de-sac |
25' 25' |
25' 25' |
25' 25' | ||||
| F | Side Setback (min) | 7.5' | 5' | 5' | ||||
| G | Corner Side Setback (min) - Through Lot, Lot Back-to-Back or Lot Backing to Amenity Space - Other |
15' 25' |
10' 20' |
10' 20' | ||||
| H | Rear Setback (min) - Non-through lot - Through lot |
25' 30' |
20' 25' |
15' 20' | ||||
| Accessory Building Placement for Structures 15' in Height or greater, not to exceed 30' in height | ||||||||
| I | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | Same as side setback of the primary building placement | ||||||
| K | Corner Side Setback (min) | Same as the front setback of the primary building placement | ||||||
| L | Rear Setback (min) | Half of the rear setback of the primary building placement | ||||||
| Accessory Building Placement for Structures under 15' in height | ||||||||
| M | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| N | Side Setback (min) | 3.75' | ||||||
| O | Corner Side Setback (min) | Same as front setback of the primary building placement | ||||||
| P | Rear Setback (min) - Non-through lot - Through lot |
5' 30 | ||||||
| Building Height | ||||||||
| Q | Height (max) | 45' | 45' | 45' | ||||
| Access and Parking [4] | ||||||||
| R | Parking Location | On-street or on-site | On-street, on-site | On-street, or on-site | ||||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | ||||
Notes:
| ||||||||
| Table 19.2-12.1, Semi-Urban Neighborhood (SU) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||||||
| Development | Base | Option 1 | Option 2 | |||||
| Key | Neighborhood Type | Single-Family | Single-Family | Single-Family | ||||
| -- | Amenity Space (min) [1] | 10% | 12.5% | 15% | ||||
| Strategic Amenity Space (min) | 0.01 ac/du | 0.01 ac/du | 0.01 ac/du | |||||
| Lot Standards | ||||||||
| A | Lot Area (min) | 7,500 sf. | 6,000 sf. | 4,500 sf. | ||||
| B | Lot Width (min) | 75' | 60' | 45' | ||||
| C | Road Frontage (min) [2] - Cul-de-sac or loop road - Other road |
25' 50' |
25' 40' |
25' 25' | ||||
| D | Building coverage (max) [1] | 40% | 50% | 60% | ||||
| Building Standards | ||||||||
| Principal Building Placement [3] | ||||||||
| E | Front Setback (min) [1] - Street - Cul-de-sac |
25' 25' |
25' 25' |
25' 25' | ||||
| F | Side Setback (min) | 7.5' | 5' | 5' | ||||
| G | Corner Side Setback (min) - Through Lot, Lot Back-to-Back or Lot Backing to Amenity Space - Other |
15' 25' |
10' 20' |
10' 20' | ||||
| H | Rear Setback (min) - Non-through lot - Through lot |
25' 30' |
20' 25' |
15' 20' | ||||
| Accessory Building Placement for Structures 15' in Height or greater, not to exceed 30' in height | ||||||||
| I | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | Same as side setback of the primary building placement | ||||||
| K | Corner Side Setback (min) | Same as the front setback of the primary building placement | ||||||
| L | Rear Setback (min) | Half of the rear setback of the primary building placement | ||||||
| Accessory Building Placement for Structures under 15' in height | ||||||||
| M | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| N | Side Setback (min) | 3.75' | ||||||
| O | Corner Side Setback (min) | Same as front setback of the primary building placement | ||||||
| P | Rear Setback (min) - Non-through lot - Through lot |
5' 30 | ||||||
| Building Height | ||||||||
| Q | Height (max) | 45' | 45' | 45' | ||||
| Access and Parking [4] | ||||||||
| R | Parking Location | On-street or on-site | On-street, on-site | On-street, or on-site | ||||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | ||||
Notes:
| ||||||||
| Table 19.2-12.1, Semi-Urban Neighborhood (SU) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||||||
| Development | Base | Option 1 | Option 2 | |||||
| Key | Neighborhood Type | Single-Family | Single-Family | Single-Family | ||||
| -- | Amenity Space (min) [1] | 10% | 12.5% | 15% | ||||
| Strategic Amenity Space (min) | 0.01 ac/du | 0.01 ac/du | 0.01 ac/du | |||||
| Lot Standards | ||||||||
| A | Lot Area (min) | 7,500 sf. | 6,000 sf. | 4,500 sf. | ||||
| B | Lot Width (min) | 75' | 60' | 45' | ||||
| C | Road Frontage (min) [2] - Cul-de-sac or loop road - Other road |
25' 50' |
25' 40' |
25' 25' | ||||
| D | Building coverage (max) [1] | 40% | 50% | 60% | ||||
| Building Standards | ||||||||
| Principal Building Placement [3] | ||||||||
| E | Front Setback (min) [1] - Street - Cul-de-sac |
25' 25' |
25' 25' |
25' 25' | ||||
| F | Side Setback (min) | 7.5' | 5' | 5' | ||||
| G | Corner Side Setback (min) - Through Lot, Lot Back-to-Back or Lot Backing to Amenity Space - Other |
15' 25' |
10' 20' |
10' 20' | ||||
| H | Rear Setback (min) - Non-through lot - Through lot |
25' 30' |
20' 25' |
15' 20' | ||||
| Accessory Building Placement for Structures 15' in Height or greater, not to exceed 30' in height | ||||||||
| I | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| J | Side Setback (min) | Same as side setback of the primary building placement | ||||||
| K | Corner Side Setback (min) | Same as the front setback of the primary building placement | ||||||
| L | Rear Setback (min) | Half of the rear setback of the primary building placement | ||||||
| Accessory Building Placement for Structures under 15' in height | ||||||||
| M | Front Setback (min) | Lesser of half the average depth of the lot or 80' | ||||||
| N | Side Setback (min) | 3.75' | ||||||
| O | Corner Side Setback (min) | Same as front setback of the primary building placement | ||||||
| P | Rear Setback (min) - Non-through lot - Through lot |
5' 30 | ||||||
| Building Height | ||||||||
| Q | Height (max) | 45' | 45' | 45' | ||||
| Access and Parking [4] | ||||||||
| R | Parking Location | On-street or on-site | On-street, on-site | On-street, or on-site | ||||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | Required, unless approved for an exception by County Code Sec. 18-61. | ||||
Notes:
| ||||||||
| Figure 19.2-12.1, SU Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-12.1, SU Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-12.1, SU Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-12.1, SU Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Provisions Related to the SU District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Amenity Space | Sec. 19.2-34 |
| Dimensional Standards | Sec. 19.2-37 |
| Landscaping and Screening | Sec. 19.2-41 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
(ZO-2025-002, Relative to Auto Sales, Required Utility Connections, and Site Plans, adopted 12/17/2025, effective 01/01/2026)
Purpose. The Transition Residential (TR) District provides for single-family attached dwellings and low-rise apartment buildings and complexes. The bulk and scale of development is designed for transitioning from suburban and semi-urban neighborhoods to urban neighborhoods, mixed-use centers, and major arterial and highway corridors. The building types include townhomes and multi-family configurations that may be compatible with single-family neighborhoods for areas nearest non-residential and mixed-use development and major corridors. The amount of amenity space is commensurate with density and may be used for buffering adjacent uses that share a common property line.
| Table 19.2-13.1, Transition Residential (TR) Lot and Building Standards [1] | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| ac = acre ' = feet | |||||||||
| Development | Base | Option 1 | |||||||
| Key | Neighborhood Type | Suburban Townhouse | Multi-Family/ Condominium | ||||||
| Vehicle Access Type | Front Loaded | Rear Loaded/Common Parking | Street | ||||||
| -- | Dwelling units per row (max) | 8 | 10 | -- | |||||
| -- | Project Size (min) | 5.0 ac | 5.0 ac | 10.0 ac | |||||
| -- | Amenity Space (min) | 20% | 10% | 15% | |||||
| Strategic Amenity Space (min) | 30% of required AS | 30% of required AS | 50% of required AS | ||||||
| Lot Standards | |||||||||
| A | Lot Depth (min) | 70' | 70' | -- | |||||
| B | Lot Width (min) | 19' [2] | 16' | -- | |||||
| C | Road Frontage | [3] | [3] | -- | |||||
| Building Standards | |||||||||
| Townhouse Building Placement (Principal and Accessory) [4] | |||||||||
| D | Front Setback (min) | 20' [5] | 10' | -- | |||||
| E | Side Setback for end unit (min) | 10' | 10' | -- | |||||
| F | Corner Side Setback (min) - Principal - Accessory |
15' 5' |
10' 5' | -- | |||||
| G | Rear Setback (min) - Principal - Accessory |
20' 5' |
20' [6] 5' | -- | |||||
| Multifamily Building Placement (Principal and Accessory)/Required Perimeter Landscaping | |||||||||
| H | Project Property Line Setback (min) | -- | -- | 30'/C | |||||
| I | Road Setback (min) - Arterial - Collector/All other public roads | -- | -- |
50'/C 25'/C | |||||
| J | Internal Roads and Private Pavement/Parking Spaces (min) | -- | -- |
15' | |||||
| Building Height | |||||||||
| K | Height (max) |
65' |
65' |
65' | |||||
| Access and Parking/Required Perimeter Landscaping | |||||||||
| L | Parking Location |
|
| Common Lot | |||||
| M | Parking pad length, exclusive of sidewalks (min) | 20' | -- | -- | |||||
| N | Parking Lot Setback (min) - Arterial - Collector - All other roads - Lots with dwellings/exterior property lines | See Sec. 19.2-35
15' 10' [9] |
See Sec. 19.2-35
15' 10' [9]
| 50'/C 25'/C [8] 25'/C 25'/C | |||||
| -- | Number of Access Points - 50 units or fewer - 51 or more units | See Sec. 17.1-84 | See Sec. 17.1-84 |
1 2 | |||||
| Utilities | |||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | ||||||
| Building Design | |||||||||
| O | Total garage door width as a percent of total building row length (max) | 60% | -- | -- | |||||
Notes:
| |||||||||
| Table 19.2-13.1, Transition Residential (TR) Lot and Building Standards [1] | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| ac = acre ' = feet | |||||||||
| Development | Base | Option 1 | |||||||
| Key | Neighborhood Type | Suburban Townhouse | Multi-Family/ Condominium | ||||||
| Vehicle Access Type | Front Loaded | Rear Loaded/Common Parking | Street | ||||||
| -- | Dwelling units per row (max) | 8 | 10 | -- | |||||
| -- | Project Size (min) | 5.0 ac | 5.0 ac | 10.0 ac | |||||
| -- | Amenity Space (min) | 20% | 10% | 15% | |||||
| Strategic Amenity Space (min) | 30% of required AS | 30% of required AS | 50% of required AS | ||||||
| Lot Standards | |||||||||
| A | Lot Depth (min) | 70' | 70' | -- | |||||
| B | Lot Width (min) | 19' [2] | 16' | -- | |||||
| C | Road Frontage | [3] | [3] | -- | |||||
| Building Standards | |||||||||
| Townhouse Building Placement (Principal and Accessory) [4] | |||||||||
| D | Front Setback (min) | 20' [5] | 10' | -- | |||||
| E | Side Setback for end unit (min) | 10' | 10' | -- | |||||
| F | Corner Side Setback (min) - Principal - Accessory |
15' 5' |
10' 5' | -- | |||||
| G | Rear Setback (min) - Principal - Accessory |
20' 5' |
20' [6] 5' | -- | |||||
| Multifamily Building Placement (Principal and Accessory)/Required Perimeter Landscaping | |||||||||
| H | Project Property Line Setback (min) | -- | -- | 30'/C | |||||
| I | Road Setback (min) - Arterial - Collector/All other public roads | -- | -- |
50'/C 25'/C | |||||
| J | Internal Roads and Private Pavement/Parking Spaces (min) | -- | -- |
15' | |||||
| Building Height | |||||||||
| K | Height (max) |
65' |
65' |
65' | |||||
| Access and Parking/Required Perimeter Landscaping | |||||||||
| L | Parking Location |
|
| Common Lot | |||||
| M | Parking pad length, exclusive of sidewalks (min) | 20' | -- | -- | |||||
| N | Parking Lot Setback (min) - Arterial - Collector - All other roads - Lots with dwellings/exterior property lines | See Sec. 19.2-35
15' 10' [9] |
See Sec. 19.2-35
15' 10' [9]
| 50'/C 25'/C [8] 25'/C 25'/C | |||||
| -- | Number of Access Points - 50 units or fewer - 51 or more units | See Sec. 17.1-84 | See Sec. 17.1-84 |
1 2 | |||||
| Utilities | |||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | ||||||
| Building Design | |||||||||
| O | Total garage door width as a percent of total building row length (max) | 60% | -- | -- | |||||
Notes:
| |||||||||
| Table 19.2-13.1, Transition Residential (TR) Lot and Building Standards [1] | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| ac = acre ' = feet | |||||||||
| Development | Base | Option 1 | |||||||
| Key | Neighborhood Type | Suburban Townhouse | Multi-Family/ Condominium | ||||||
| Vehicle Access Type | Front Loaded | Rear Loaded/Common Parking | Street | ||||||
| -- | Dwelling units per row (max) | 8 | 10 | -- | |||||
| -- | Project Size (min) | 5.0 ac | 5.0 ac | 10.0 ac | |||||
| -- | Amenity Space (min) | 20% | 10% | 15% | |||||
| Strategic Amenity Space (min) | 30% of required AS | 30% of required AS | 50% of required AS | ||||||
| Lot Standards | |||||||||
| A | Lot Depth (min) | 70' | 70' | -- | |||||
| B | Lot Width (min) | 19' [2] | 16' | -- | |||||
| C | Road Frontage | [3] | [3] | -- | |||||
| Building Standards | |||||||||
| Townhouse Building Placement (Principal and Accessory) [4] | |||||||||
| D | Front Setback (min) | 20' [5] | 10' | -- | |||||
| E | Side Setback for end unit (min) | 10' | 10' | -- | |||||
| F | Corner Side Setback (min) - Principal - Accessory |
15' 5' |
10' 5' | -- | |||||
| G | Rear Setback (min) - Principal - Accessory |
20' 5' |
20' [6] 5' | -- | |||||
| Multifamily Building Placement (Principal and Accessory)/Required Perimeter Landscaping | |||||||||
| H | Project Property Line Setback (min) | -- | -- | 30'/C | |||||
| I | Road Setback (min) - Arterial - Collector/All other public roads | -- | -- |
50'/C 25'/C | |||||
| J | Internal Roads and Private Pavement/Parking Spaces (min) | -- | -- |
15' | |||||
| Building Height | |||||||||
| K | Height (max) |
65' |
65' |
65' | |||||
| Access and Parking/Required Perimeter Landscaping | |||||||||
| L | Parking Location |
|
| Common Lot | |||||
| M | Parking pad length, exclusive of sidewalks (min) | 20' | -- | -- | |||||
| N | Parking Lot Setback (min) - Arterial - Collector - All other roads - Lots with dwellings/exterior property lines | See Sec. 19.2-35
15' 10' [9] |
See Sec. 19.2-35
15' 10' [9]
| 50'/C 25'/C [8] 25'/C 25'/C | |||||
| -- | Number of Access Points - 50 units or fewer - 51 or more units | See Sec. 17.1-84 | See Sec. 17.1-84 |
1 2 | |||||
| Utilities | |||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | ||||||
| Building Design | |||||||||
| O | Total garage door width as a percent of total building row length (max) | 60% | -- | -- | |||||
Notes:
| |||||||||
| Table 19.2-13.1, Transition Residential (TR) Lot and Building Standards [1] | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| ac = acre ' = feet | |||||||||
| Development | Base | Option 1 | |||||||
| Key | Neighborhood Type | Suburban Townhouse | Multi-Family/ Condominium | ||||||
| Vehicle Access Type | Front Loaded | Rear Loaded/Common Parking | Street | ||||||
| -- | Dwelling units per row (max) | 8 | 10 | -- | |||||
| -- | Project Size (min) | 5.0 ac | 5.0 ac | 10.0 ac | |||||
| -- | Amenity Space (min) | 20% | 10% | 15% | |||||
| Strategic Amenity Space (min) | 30% of required AS | 30% of required AS | 50% of required AS | ||||||
| Lot Standards | |||||||||
| A | Lot Depth (min) | 70' | 70' | -- | |||||
| B | Lot Width (min) | 19' [2] | 16' | -- | |||||
| C | Road Frontage | [3] | [3] | -- | |||||
| Building Standards | |||||||||
| Townhouse Building Placement (Principal and Accessory) [4] | |||||||||
| D | Front Setback (min) | 20' [5] | 10' | -- | |||||
| E | Side Setback for end unit (min) | 10' | 10' | -- | |||||
| F | Corner Side Setback (min) - Principal - Accessory |
15' 5' |
10' 5' | -- | |||||
| G | Rear Setback (min) - Principal - Accessory |
20' 5' |
20' [6] 5' | -- | |||||
| Multifamily Building Placement (Principal and Accessory)/Required Perimeter Landscaping | |||||||||
| H | Project Property Line Setback (min) | -- | -- | 30'/C | |||||
| I | Road Setback (min) - Arterial - Collector/All other public roads | -- | -- |
50'/C 25'/C | |||||
| J | Internal Roads and Private Pavement/Parking Spaces (min) | -- | -- |
15' | |||||
| Building Height | |||||||||
| K | Height (max) |
65' |
65' |
65' | |||||
| Access and Parking/Required Perimeter Landscaping | |||||||||
| L | Parking Location |
|
| Common Lot | |||||
| M | Parking pad length, exclusive of sidewalks (min) | 20' | -- | -- | |||||
| N | Parking Lot Setback (min) - Arterial - Collector - All other roads - Lots with dwellings/exterior property lines | See Sec. 19.2-35
15' 10' [9] |
See Sec. 19.2-35
15' 10' [9]
| 50'/C 25'/C [8] 25'/C 25'/C | |||||
| -- | Number of Access Points - 50 units or fewer - 51 or more units | See Sec. 17.1-84 | See Sec. 17.1-84 |
1 2 | |||||
| Utilities | |||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | ||||||
| Building Design | |||||||||
| O | Total garage door width as a percent of total building row length (max) | 60% | -- | -- | |||||
Notes:
| |||||||||
| Figure 19.2-12.1, TR Illustrated Renderings |
|---|
| Base - Front Loaded Suburban Townhouse |
![]() |
![]() |
![]() |
| Base - Rear Loaded/Common Parking Suburban Townhouse |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-12.1, TR Illustrated Renderings |
|---|
| Base - Front Loaded Suburban Townhouse |
![]() |
![]() |
![]() |
| Base - Rear Loaded/Common Parking Suburban Townhouse |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-12.1, TR Illustrated Renderings |
|---|
| Base - Front Loaded Suburban Townhouse |
![]() |
![]() |
![]() |
| Base - Rear Loaded/Common Parking Suburban Townhouse |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-12.1, TR Illustrated Renderings |
|---|
| Base - Front Loaded Suburban Townhouse |
![]() |
![]() |
![]() |
| Base - Rear Loaded/Common Parking Suburban Townhouse |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Provisions Related to the TR District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Amenity Space | Sec. 19.2-34 |
| Dimensional Standards | Sec. 19.2-37 |
| Landscaping and Screening | Sec. 19.2-41 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
Purpose. The Urban Residential (UR) District provides for single-family attached, multi-family, and vertically integrated mixed-use buildings and developments. The district is intended for areas within or adjacent to mixed-use centers to serve as a higher-density residential transition from suburban and semi-urban neighborhoods. Given its urban transition character and higher densities, more formal amenity spaces are set aside for small lawns, streetscapes, greens, plazas, and resident gathering areas. Amenities should be linked together with abutting developments to create a system of interconnected public spaces. The role of the UR District is to provide a variety of living types and spaces in proximity to, and in support of, mixed-use centers. Areas zoned UR require connection to the public water and wastewater systems and should be located near major transportation corridors.
Option 2. This option provides for urban-style mixed-use buildings in a walkable setting. Parking should be internal to the development.
| Table 19.2-14.1, Urban Residential (UR) Lot and Building Standards[1] | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| ' = feet | |||||||||
| Development | Base | Option 1 [2] | Option 2 [3] | ||||||
| Key | Neighborhood Type | Urban Townhouse | Multi-Family/ Condominium | Vertical Mixed-Use | |||||
| -- | Amenity Space (min) | 10% | 10% | 10% | |||||
-- | Strategic Amenity Space (min) | 30% of required AS | 50% of required AS | 75% of required AS | |||||
| -- | Road Frontage | [4] | [4] | [4] | |||||
| Building Standards | |||||||||
| Townhouse Building Placement (Principal and Accessory) | |||||||||
| A | Front Setback (min) | 10' | -- | -- | |||||
| B | Side Setback for end unit (min) | 5' | -- | -- | |||||
| C | Corner Side Setback (min) | 10' | -- | -- | |||||
| D | Rear Setback (min) - Principal - Accessory |
20' [5] 5' |
-- -- |
-- -- | |||||
| Multi-family Building Placement (Principal and Accessory)/Required Perimeter Landscaping | |||||||||
| E | Frontage Buildout (min) | -- | 60% | 60% | |||||
| F | Project Property Line Setback (min) | -- | 10' [6] | 10' [6] | |||||
| G | Road Setback (min) - Collector or Arterial - All other public roads |
-- -- |
20'/A 10'/A |
20'/A 10'/A | |||||
| H | Interior Private Pavement (min) | -- | 5' | 5' | |||||
| Building Height | |||||||||
| I | Height (max) [7] | 75' | 90' | 105' | |||||
| Access and Parking [8] | |||||||||
| J | Parking Location |
|
|
| |||||
| K | Parking Lot Setback/Required Perimeter Landscaping [9] | 5' | Same as principal building placement | Same as principal building placement | |||||
| -- | Number of Access Points - 50 units or Fewer - 51 or more |
See Sec. 17.1-84 |
See Sec. 17.1-84 |
1 2 | |||||
| Utilities | |||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | Required | |||||
Notes:
| |||||||||
| Table 19.2-14.1, Urban Residential (UR) Lot and Building Standards[1] | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| ' = feet | |||||||||
| Development | Base | Option 1 [2] | Option 2 [3] | ||||||
| Key | Neighborhood Type | Urban Townhouse | Multi-Family/ Condominium | Vertical Mixed-Use | |||||
| -- | Amenity Space (min) | 10% | 10% | 10% | |||||
-- | Strategic Amenity Space (min) | 30% of required AS | 50% of required AS | 75% of required AS | |||||
| -- | Road Frontage | [4] | [4] | [4] | |||||
| Building Standards | |||||||||
| Townhouse Building Placement (Principal and Accessory) | |||||||||
| A | Front Setback (min) | 10' | -- | -- | |||||
| B | Side Setback for end unit (min) | 5' | -- | -- | |||||
| C | Corner Side Setback (min) | 10' | -- | -- | |||||
| D | Rear Setback (min) - Principal - Accessory |
20' [5] 5' |
-- -- |
-- -- | |||||
| Multi-family Building Placement (Principal and Accessory)/Required Perimeter Landscaping | |||||||||
| E | Frontage Buildout (min) | -- | 60% | 60% | |||||
| F | Project Property Line Setback (min) | -- | 10' [6] | 10' [6] | |||||
| G | Road Setback (min) - Collector or Arterial - All other public roads |
-- -- |
20'/A 10'/A |
20'/A 10'/A | |||||
| H | Interior Private Pavement (min) | -- | 5' | 5' | |||||
| Building Height | |||||||||
| I | Height (max) [7] | 75' | 90' | 105' | |||||
| Access and Parking [8] | |||||||||
| J | Parking Location |
|
|
| |||||
| K | Parking Lot Setback/Required Perimeter Landscaping [9] | 5' | Same as principal building placement | Same as principal building placement | |||||
| -- | Number of Access Points - 50 units or Fewer - 51 or more |
See Sec. 17.1-84 |
See Sec. 17.1-84 |
1 2 | |||||
| Utilities | |||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | Required | |||||
Notes:
| |||||||||
| Table 19.2-14.1, Urban Residential (UR) Lot and Building Standards[1] | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| ' = feet | |||||||||
| Development | Base | Option 1 [2] | Option 2 [3] | ||||||
| Key | Neighborhood Type | Urban Townhouse | Multi-Family/ Condominium | Vertical Mixed-Use | |||||
| -- | Amenity Space (min) | 10% | 10% | 10% | |||||
-- | Strategic Amenity Space (min) | 30% of required AS | 50% of required AS | 75% of required AS | |||||
| -- | Road Frontage | [4] | [4] | [4] | |||||
| Building Standards | |||||||||
| Townhouse Building Placement (Principal and Accessory) | |||||||||
| A | Front Setback (min) | 10' | -- | -- | |||||
| B | Side Setback for end unit (min) | 5' | -- | -- | |||||
| C | Corner Side Setback (min) | 10' | -- | -- | |||||
| D | Rear Setback (min) - Principal - Accessory |
20' [5] 5' |
-- -- |
-- -- | |||||
| Multi-family Building Placement (Principal and Accessory)/Required Perimeter Landscaping | |||||||||
| E | Frontage Buildout (min) | -- | 60% | 60% | |||||
| F | Project Property Line Setback (min) | -- | 10' [6] | 10' [6] | |||||
| G | Road Setback (min) - Collector or Arterial - All other public roads |
-- -- |
20'/A 10'/A |
20'/A 10'/A | |||||
| H | Interior Private Pavement (min) | -- | 5' | 5' | |||||
| Building Height | |||||||||
| I | Height (max) [7] | 75' | 90' | 105' | |||||
| Access and Parking [8] | |||||||||
| J | Parking Location |
|
|
| |||||
| K | Parking Lot Setback/Required Perimeter Landscaping [9] | 5' | Same as principal building placement | Same as principal building placement | |||||
| -- | Number of Access Points - 50 units or Fewer - 51 or more |
See Sec. 17.1-84 |
See Sec. 17.1-84 |
1 2 | |||||
| Utilities | |||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | Required | |||||
Notes:
| |||||||||
| Table 19.2-14.1, Urban Residential (UR) Lot and Building Standards[1] | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| ' = feet | |||||||||
| Development | Base | Option 1 [2] | Option 2 [3] | ||||||
| Key | Neighborhood Type | Urban Townhouse | Multi-Family/ Condominium | Vertical Mixed-Use | |||||
| -- | Amenity Space (min) | 10% | 10% | 10% | |||||
-- | Strategic Amenity Space (min) | 30% of required AS | 50% of required AS | 75% of required AS | |||||
| -- | Road Frontage | [4] | [4] | [4] | |||||
| Building Standards | |||||||||
| Townhouse Building Placement (Principal and Accessory) | |||||||||
| A | Front Setback (min) | 10' | -- | -- | |||||
| B | Side Setback for end unit (min) | 5' | -- | -- | |||||
| C | Corner Side Setback (min) | 10' | -- | -- | |||||
| D | Rear Setback (min) - Principal - Accessory |
20' [5] 5' |
-- -- |
-- -- | |||||
| Multi-family Building Placement (Principal and Accessory)/Required Perimeter Landscaping | |||||||||
| E | Frontage Buildout (min) | -- | 60% | 60% | |||||
| F | Project Property Line Setback (min) | -- | 10' [6] | 10' [6] | |||||
| G | Road Setback (min) - Collector or Arterial - All other public roads |
-- -- |
20'/A 10'/A |
20'/A 10'/A | |||||
| H | Interior Private Pavement (min) | -- | 5' | 5' | |||||
| Building Height | |||||||||
| I | Height (max) [7] | 75' | 90' | 105' | |||||
| Access and Parking [8] | |||||||||
| J | Parking Location |
|
|
| |||||
| K | Parking Lot Setback/Required Perimeter Landscaping [9] | 5' | Same as principal building placement | Same as principal building placement | |||||
| -- | Number of Access Points - 50 units or Fewer - 51 or more |
See Sec. 17.1-84 |
See Sec. 17.1-84 |
1 2 | |||||
| Utilities | |||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | Required | |||||
Notes:
| |||||||||
| Figure 19.2-14.1, Illustrated UR Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-14.1, Illustrated UR Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-14.1, Illustrated UR Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-14.1, Illustrated UR Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Provisions Related to the UR District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Amenity Space | Sec. 19.2-34 |
| Building Design | Sec. 19.2-36 |
| Dimensional Standards | Sec. 19.2-37 |
| Landscaping and Screening | Sec. 19.2-41 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
Purpose. The Alternative Residential (AR) District provides for a variety of different types and arrangements of housing that may be constructed or manufactured on- or off-site and which may be placed on individual lots or a common lot. This district may accommodate manufactured or tiny home subdivisions, as well as innovative and emerging residential housing concepts.
| Table 19.2-15.1, Alternative Residential (AR) Lot and Building Standards | |||||||
|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | |||||||
| Development | Base | Option 1 | |||||
| Key | Neighborhood Type | Subdivision (Fee Simple) [1][2] | Common Lot | ||||
| -- | Amenity Space (min) | 10% | 10% | ||||
| -- | Strategic Amenity Space (min) | 0.01 ac/du | 0.01 ac/du | ||||
| -- | Road Frontage (min) | [3] | -- | ||||
| -- | Project Size (min) | 3.0 ac | 3.0 ac | ||||
| Lot Standards | |||||||
| A | Lot Area (min) | 1,500 sf. | -- | ||||
| B | Lot Width (min) | 25' | -- | ||||
| Building Standards | |||||||
| Building Placement - Subdivision (Principal and Accessory) | |||||||
| C | Front Setback (min) | 20' [4] | -- | ||||
| D | Side Setback (min) | 5' | -- | ||||
| E | Corner Side Setback (min) | 15' | -- | ||||
| F | Rear Setback (min) | 5' | -- | ||||
| Building Placement - Common Lot (Principal and Accessory)/Required Perimeter Landscaping | |||||||
| G | Road Setback (min) - Collector or Arterial - All other public roads | -- |
50'/C 25'/C | ||||
| H | Property Line Setback (min) | -- | 25'/B | ||||
| I | Internal private pavement setback (min) | -- | 5' | ||||
| Building Height and Coverage | |||||||
| J | Height (max) | 45' | 45' | ||||
| K | Building Coverage (max) | 70% | -- | ||||
| Access and Parking | |||||||
| L | Parking Location |
|
| ||||
| M | Parking Lot Setback from road (min) | Same as principal building | Same as principal buildings | ||||
| -- | Number of Access Points - Fewer than 50 units - 50 or more |
1 2 |
1 2 | ||||
| Utilities | |||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | ||||
Notes:
| |||||||
| Table 19.2-15.1, Alternative Residential (AR) Lot and Building Standards | |||||||
|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | |||||||
| Development | Base | Option 1 | |||||
| Key | Neighborhood Type | Subdivision (Fee Simple) [1][2] | Common Lot | ||||
| -- | Amenity Space (min) | 10% | 10% | ||||
| -- | Strategic Amenity Space (min) | 0.01 ac/du | 0.01 ac/du | ||||
| -- | Road Frontage (min) | [3] | -- | ||||
| -- | Project Size (min) | 3.0 ac | 3.0 ac | ||||
| Lot Standards | |||||||
| A | Lot Area (min) | 1,500 sf. | -- | ||||
| B | Lot Width (min) | 25' | -- | ||||
| Building Standards | |||||||
| Building Placement - Subdivision (Principal and Accessory) | |||||||
| C | Front Setback (min) | 20' [4] | -- | ||||
| D | Side Setback (min) | 5' | -- | ||||
| E | Corner Side Setback (min) | 15' | -- | ||||
| F | Rear Setback (min) | 5' | -- | ||||
| Building Placement - Common Lot (Principal and Accessory)/Required Perimeter Landscaping | |||||||
| G | Road Setback (min) - Collector or Arterial - All other public roads | -- |
50'/C 25'/C | ||||
| H | Property Line Setback (min) | -- | 25'/B | ||||
| I | Internal private pavement setback (min) | -- | 5' | ||||
| Building Height and Coverage | |||||||
| J | Height (max) | 45' | 45' | ||||
| K | Building Coverage (max) | 70% | -- | ||||
| Access and Parking | |||||||
| L | Parking Location |
|
| ||||
| M | Parking Lot Setback from road (min) | Same as principal building | Same as principal buildings | ||||
| -- | Number of Access Points - Fewer than 50 units - 50 or more |
1 2 |
1 2 | ||||
| Utilities | |||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | ||||
Notes:
| |||||||
| Table 19.2-15.1, Alternative Residential (AR) Lot and Building Standards | |||||||
|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | |||||||
| Development | Base | Option 1 | |||||
| Key | Neighborhood Type | Subdivision (Fee Simple) [1][2] | Common Lot | ||||
| -- | Amenity Space (min) | 10% | 10% | ||||
| -- | Strategic Amenity Space (min) | 0.01 ac/du | 0.01 ac/du | ||||
| -- | Road Frontage (min) | [3] | -- | ||||
| -- | Project Size (min) | 3.0 ac | 3.0 ac | ||||
| Lot Standards | |||||||
| A | Lot Area (min) | 1,500 sf. | -- | ||||
| B | Lot Width (min) | 25' | -- | ||||
| Building Standards | |||||||
| Building Placement - Subdivision (Principal and Accessory) | |||||||
| C | Front Setback (min) | 20' [4] | -- | ||||
| D | Side Setback (min) | 5' | -- | ||||
| E | Corner Side Setback (min) | 15' | -- | ||||
| F | Rear Setback (min) | 5' | -- | ||||
| Building Placement - Common Lot (Principal and Accessory)/Required Perimeter Landscaping | |||||||
| G | Road Setback (min) - Collector or Arterial - All other public roads | -- |
50'/C 25'/C | ||||
| H | Property Line Setback (min) | -- | 25'/B | ||||
| I | Internal private pavement setback (min) | -- | 5' | ||||
| Building Height and Coverage | |||||||
| J | Height (max) | 45' | 45' | ||||
| K | Building Coverage (max) | 70% | -- | ||||
| Access and Parking | |||||||
| L | Parking Location |
|
| ||||
| M | Parking Lot Setback from road (min) | Same as principal building | Same as principal buildings | ||||
| -- | Number of Access Points - Fewer than 50 units - 50 or more |
1 2 |
1 2 | ||||
| Utilities | |||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | ||||
Notes:
| |||||||
| Table 19.2-15.1, Alternative Residential (AR) Lot and Building Standards | |||||||
|---|---|---|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | |||||||
| Development | Base | Option 1 | |||||
| Key | Neighborhood Type | Subdivision (Fee Simple) [1][2] | Common Lot | ||||
| -- | Amenity Space (min) | 10% | 10% | ||||
| -- | Strategic Amenity Space (min) | 0.01 ac/du | 0.01 ac/du | ||||
| -- | Road Frontage (min) | [3] | -- | ||||
| -- | Project Size (min) | 3.0 ac | 3.0 ac | ||||
| Lot Standards | |||||||
| A | Lot Area (min) | 1,500 sf. | -- | ||||
| B | Lot Width (min) | 25' | -- | ||||
| Building Standards | |||||||
| Building Placement - Subdivision (Principal and Accessory) | |||||||
| C | Front Setback (min) | 20' [4] | -- | ||||
| D | Side Setback (min) | 5' | -- | ||||
| E | Corner Side Setback (min) | 15' | -- | ||||
| F | Rear Setback (min) | 5' | -- | ||||
| Building Placement - Common Lot (Principal and Accessory)/Required Perimeter Landscaping | |||||||
| G | Road Setback (min) - Collector or Arterial - All other public roads | -- |
50'/C 25'/C | ||||
| H | Property Line Setback (min) | -- | 25'/B | ||||
| I | Internal private pavement setback (min) | -- | 5' | ||||
| Building Height and Coverage | |||||||
| J | Height (max) | 45' | 45' | ||||
| K | Building Coverage (max) | 70% | -- | ||||
| Access and Parking | |||||||
| L | Parking Location |
|
| ||||
| M | Parking Lot Setback from road (min) | Same as principal building | Same as principal buildings | ||||
| -- | Number of Access Points - Fewer than 50 units - 50 or more |
1 2 |
1 2 | ||||
| Utilities | |||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | ||||
Notes:
| |||||||
| Figure 19.2-15.1, AR Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-15.1, AR Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-15.1, AR Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-15.1, AR Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Provisions Related to the AR District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Amenity Space | Sec. 19.2-34 |
| Dimensional Standards | Sec. 19.2-37 |
| Landscaping and Screening | Sec. 19.2-41 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
Purpose. The Neighborhood Business (NB) District provides for small-scale and neighborhood serving commercial, office, retail and service uses. To ensure compatibility within both rural and suburban contexts, limitations are established to manage the type and scale of uses and buildings. This district is most often located at neighborhood entrances, collector street intersections, along the frontage of streets bounding neighborhoods, and as small centers within a master planned development. In established areas along arterial corridors, this district may also be used for existing homes that warrant transition to live-work units or office conversions. This District also applies to rural intersections providing convenience uses to area residents. The nature of this district makes it appropriate as a transition between the Corridor Commercial District and Residential Districts.
| Table 19.2-16, Neighborhood Business (NB) Lot and Building Standards | |||||
|---|---|---|---|---|---|
| sf. = square feet ' = feet | |||||
| Development | Base | Option 1 | |||
| Key | Category | Neighborhood Commercial | Rural | ||
| -- | Gross Floor Area per building (max) | 20,000 sf. [1] | 10,000 sf. | ||
| -- | Amenity Space (min) | 5% | -- | ||
| Building and Parking Standards | |||||
| Building Setbacks / Required Perimeter Landscaping | |||||
| A | Road Setback (min) - Arterial Road - Collector/Local Road - Internal Road |
30'/C 25'/C 10'/A |
50'/B 25'/B 10'/A | ||
| B | Other Property Lines Setback (min) [2] | 10'/B | 25'/B | ||
| Building Height | |||||
| C | Height (max) | 45' | 45' | ||
| Parking Setback/Required Perimeter Landscaping | |||||
| D | Parking Lot Setback (min) - Arterial Road - All Other Roads/Property Lines |
50'/A 25'/C |
50'/A 25'/C | ||
| Utilities | |||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Water Required; Wastewater Not Required | ||
| Other Limitations | |||||
| -- | Hours of Operation | 6:00 AM to 9:00 PM | 6:00 AM to 9:00 PM | ||
Notes:
| |||||
| Table 19.2-16, Neighborhood Business (NB) Lot and Building Standards | |||||
|---|---|---|---|---|---|
| sf. = square feet ' = feet | |||||
| Development | Base | Option 1 | |||
| Key | Category | Neighborhood Commercial | Rural | ||
| -- | Gross Floor Area per building (max) | 20,000 sf. [1] | 10,000 sf. | ||
| -- | Amenity Space (min) | 5% | -- | ||
| Building and Parking Standards | |||||
| Building Setbacks / Required Perimeter Landscaping | |||||
| A | Road Setback (min) - Arterial Road - Collector/Local Road - Internal Road |
30'/C 25'/C 10'/A |
50'/B 25'/B 10'/A | ||
| B | Other Property Lines Setback (min) [2] | 10'/B | 25'/B | ||
| Building Height | |||||
| C | Height (max) | 45' | 45' | ||
| Parking Setback/Required Perimeter Landscaping | |||||
| D | Parking Lot Setback (min) - Arterial Road - All Other Roads/Property Lines |
50'/A 25'/C |
50'/A 25'/C | ||
| Utilities | |||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Water Required; Wastewater Not Required | ||
| Other Limitations | |||||
| -- | Hours of Operation | 6:00 AM to 9:00 PM | 6:00 AM to 9:00 PM | ||
Notes:
| |||||
| Table 19.2-16, Neighborhood Business (NB) Lot and Building Standards | |||||
|---|---|---|---|---|---|
| sf. = square feet ' = feet | |||||
| Development | Base | Option 1 | |||
| Key | Category | Neighborhood Commercial | Rural | ||
| -- | Gross Floor Area per building (max) | 20,000 sf. [1] | 10,000 sf. | ||
| -- | Amenity Space (min) | 5% | -- | ||
| Building and Parking Standards | |||||
| Building Setbacks / Required Perimeter Landscaping | |||||
| A | Road Setback (min) - Arterial Road - Collector/Local Road - Internal Road |
30'/C 25'/C 10'/A |
50'/B 25'/B 10'/A | ||
| B | Other Property Lines Setback (min) [2] | 10'/B | 25'/B | ||
| Building Height | |||||
| C | Height (max) | 45' | 45' | ||
| Parking Setback/Required Perimeter Landscaping | |||||
| D | Parking Lot Setback (min) - Arterial Road - All Other Roads/Property Lines |
50'/A 25'/C |
50'/A 25'/C | ||
| Utilities | |||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Water Required; Wastewater Not Required | ||
| Other Limitations | |||||
| -- | Hours of Operation | 6:00 AM to 9:00 PM | 6:00 AM to 9:00 PM | ||
Notes:
| |||||
| Table 19.2-16, Neighborhood Business (NB) Lot and Building Standards | |||||
|---|---|---|---|---|---|
| sf. = square feet ' = feet | |||||
| Development | Base | Option 1 | |||
| Key | Category | Neighborhood Commercial | Rural | ||
| -- | Gross Floor Area per building (max) | 20,000 sf. [1] | 10,000 sf. | ||
| -- | Amenity Space (min) | 5% | -- | ||
| Building and Parking Standards | |||||
| Building Setbacks / Required Perimeter Landscaping | |||||
| A | Road Setback (min) - Arterial Road - Collector/Local Road - Internal Road |
30'/C 25'/C 10'/A |
50'/B 25'/B 10'/A | ||
| B | Other Property Lines Setback (min) [2] | 10'/B | 25'/B | ||
| Building Height | |||||
| C | Height (max) | 45' | 45' | ||
| Parking Setback/Required Perimeter Landscaping | |||||
| D | Parking Lot Setback (min) - Arterial Road - All Other Roads/Property Lines |
50'/A 25'/C |
50'/A 25'/C | ||
| Utilities | |||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Water Required; Wastewater Not Required | ||
| Other Limitations | |||||
| -- | Hours of Operation | 6:00 AM to 9:00 PM | 6:00 AM to 9:00 PM | ||
Notes:
| |||||
| Figure 19.2-16.1, NB Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-16.1, NB Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-16.1, NB Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-16.1, NB Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Provisions Related to the NB District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Amenity Space | Sec. 19.2-34 |
| Buffers | Sec. 19.2-35 |
| Building Design | Sec. 19.2-36 |
| Landscaping and Screening | Sec. 19.2-41 |
| Exterior Lighting | Sec. 19.2-38 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
Purpose. The Corridor Commercial (CC) District provides for a variety of commercial, office, retail, and service uses in both freestanding and multi-tenant buildings and centers. Sites within this district may vary in size and scale depending upon the types and characteristics of land use and their locations along corridor frontages (abutting neighborhoods), near intersections or when combined with office uses.
Due to the variety of land uses, larger footprints of buildings, and the expanse of parking, site design is of great importance to ensure sites are functional and efficient in moving both vehicles and pedestrians. Attractive building design is important to realize quality, sustainable developments of an enduring value. Buffering, landscaping, and screening are essential to transition uses and districts of different intensities, to enhance visual character, and for their ecological benefits.
| Table 19.2-17.1, Corridor Commercial (CC) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ' = feet | ||||||||
| Development | Base | Option 1 | Option 2 | |||||
| Key | Category | Freestanding Commercial | Center | CC with Residential [1] | ||||
| -- | Amenity Space (min) | -- | 7.5% | 10% | ||||
| Strategic Amenity Space (min) | -- | 30% of required AS | 50% of required AS | |||||
| Building Standards | ||||||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||||||
| A | Front/Road Setback (min) - Arterial - Collector/Other Roads - Internal Roads |
50'/C 25'/C 10'/A |
50'/C 25'/C 10'/A |
50'/C 25'/C 10'/A | ||||
| B | Other Property Lines Setback (min) | 10'/B | 10'/B | 10'/B | ||||
| Building Height [2] | ||||||||
| C | Height (max) | 65' | 65' | 65' | ||||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | Required | ||||
Notes:
| ||||||||
| Table 19.2-17.1, Corridor Commercial (CC) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ' = feet | ||||||||
| Development | Base | Option 1 | Option 2 | |||||
| Key | Category | Freestanding Commercial | Center | CC with Residential [1] | ||||
| -- | Amenity Space (min) | -- | 7.5% | 10% | ||||
| Strategic Amenity Space (min) | -- | 30% of required AS | 50% of required AS | |||||
| Building Standards | ||||||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||||||
| A | Front/Road Setback (min) - Arterial - Collector/Other Roads - Internal Roads |
50'/C 25'/C 10'/A |
50'/C 25'/C 10'/A |
50'/C 25'/C 10'/A | ||||
| B | Other Property Lines Setback (min) | 10'/B | 10'/B | 10'/B | ||||
| Building Height [2] | ||||||||
| C | Height (max) | 65' | 65' | 65' | ||||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | Required | ||||
Notes:
| ||||||||
| Table 19.2-17.1, Corridor Commercial (CC) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ' = feet | ||||||||
| Development | Base | Option 1 | Option 2 | |||||
| Key | Category | Freestanding Commercial | Center | CC with Residential [1] | ||||
| -- | Amenity Space (min) | -- | 7.5% | 10% | ||||
| Strategic Amenity Space (min) | -- | 30% of required AS | 50% of required AS | |||||
| Building Standards | ||||||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||||||
| A | Front/Road Setback (min) - Arterial - Collector/Other Roads - Internal Roads |
50'/C 25'/C 10'/A |
50'/C 25'/C 10'/A |
50'/C 25'/C 10'/A | ||||
| B | Other Property Lines Setback (min) | 10'/B | 10'/B | 10'/B | ||||
| Building Height [2] | ||||||||
| C | Height (max) | 65' | 65' | 65' | ||||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | Required | ||||
Notes:
| ||||||||
| Table 19.2-17.1, Corridor Commercial (CC) Lot and Building Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| ' = feet | ||||||||
| Development | Base | Option 1 | Option 2 | |||||
| Key | Category | Freestanding Commercial | Center | CC with Residential [1] | ||||
| -- | Amenity Space (min) | -- | 7.5% | 10% | ||||
| Strategic Amenity Space (min) | -- | 30% of required AS | 50% of required AS | |||||
| Building Standards | ||||||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||||||
| A | Front/Road Setback (min) - Arterial - Collector/Other Roads - Internal Roads |
50'/C 25'/C 10'/A |
50'/C 25'/C 10'/A |
50'/C 25'/C 10'/A | ||||
| B | Other Property Lines Setback (min) | 10'/B | 10'/B | 10'/B | ||||
| Building Height [2] | ||||||||
| C | Height (max) | 65' | 65' | 65' | ||||
| Utilities | ||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | Required | ||||
Notes:
| ||||||||
| Figure 19.2-17.1, CC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-17.1, CC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-17.1, CC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-17.1, CC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Provisions Related to the CC District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Amenity Space | Sec. 19.2-34 |
| Buffers | Sec. 19.2-35 |
| Building Design | Sec. 19.2-36 |
| Buffers | Sec. 19.2-35 |
| Exterior Lighting | Sec. 19.2-38 |
| Landscaping and Screening | Sec. 19.2-41 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
Purpose. The Mixed-Use Center (MU) District provides for the development of mixed-use centers at different scales and in different contexts. Mixed-use may include single-family attached and multifamily residential, together with commercial retail, service, entertainment, and office uses that may be designed in horizontal or vertical formats. Development in the MU District that includes residential uses should incorporate a variety of housing options and pedestrian-oriented design to ensure connectivity between uses for a cohesive development. This development type and form may serve as a node for several neighborhoods, as an urban activity center, or a regional destination located off of key highway interchanges. This district may also facilitate the redevelopment of underutilized shopping centers by redesigning the site to integrate other use and building types.
| Table 19.2-18.1, Mixed-Use Center (MU) Lot and Building Standards [1] | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| ' = feet | |||||||||
| Development | Base | Option 1 | Option 2 | ||||||
| Key | Category | Neighborhood | Community | Regional | |||||
Gross Floor Area Ratio [2] - Commercial (min)/Residential (max) | 15%/85% | 15%/85% | 15%/85% | ||||||
| Amenity Space (min) | 10% | 10% | 10% | ||||||
| Strategic Amenity Space (min) | 30% of required AS | 50% of required AS | 75% of required AS | ||||||
| Building Standards [3][4] | |||||||||
| Building Placement/Required Perimeter Landscaping | |||||||||
| A | Frontage Buildout (min) | 50% | 60% | 70% | |||||
| B | Road Setback (min) | 10'/A | 10'/A | 10'/A | |||||
| C | Other Property Lines Setback (min) | 10'/A | 10'/A | 10'/A | |||||
| Building Height | |||||||||
| D | Height (min/max) | --/45' | 30'/75' [5] | 30'/150' | |||||
| Parking | |||||||||
| E | Parking Location |
|
|
| |||||
| F | Parking Lot Setback (min)/Required Perimeter Landscaping [3][6][7] | 10'/A | 10'/A | 10'/A | |||||
| Utilities | |||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | Required | |||||
Notes:
| |||||||||
| Table 19.2-18.1, Mixed-Use Center (MU) Lot and Building Standards [1] | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| ' = feet | |||||||||
| Development | Base | Option 1 | Option 2 | ||||||
| Key | Category | Neighborhood | Community | Regional | |||||
Gross Floor Area Ratio [2] - Commercial (min)/Residential (max) | 15%/85% | 15%/85% | 15%/85% | ||||||
| Amenity Space (min) | 10% | 10% | 10% | ||||||
| Strategic Amenity Space (min) | 30% of required AS | 50% of required AS | 75% of required AS | ||||||
| Building Standards [3][4] | |||||||||
| Building Placement/Required Perimeter Landscaping | |||||||||
| A | Frontage Buildout (min) | 50% | 60% | 70% | |||||
| B | Road Setback (min) | 10'/A | 10'/A | 10'/A | |||||
| C | Other Property Lines Setback (min) | 10'/A | 10'/A | 10'/A | |||||
| Building Height | |||||||||
| D | Height (min/max) | --/45' | 30'/75' [5] | 30'/150' | |||||
| Parking | |||||||||
| E | Parking Location |
|
|
| |||||
| F | Parking Lot Setback (min)/Required Perimeter Landscaping [3][6][7] | 10'/A | 10'/A | 10'/A | |||||
| Utilities | |||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | Required | |||||
Notes:
| |||||||||
| Table 19.2-18.1, Mixed-Use Center (MU) Lot and Building Standards [1] | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| ' = feet | |||||||||
| Development | Base | Option 1 | Option 2 | ||||||
| Key | Category | Neighborhood | Community | Regional | |||||
Gross Floor Area Ratio [2] - Commercial (min)/Residential (max) | 15%/85% | 15%/85% | 15%/85% | ||||||
| Amenity Space (min) | 10% | 10% | 10% | ||||||
| Strategic Amenity Space (min) | 30% of required AS | 50% of required AS | 75% of required AS | ||||||
| Building Standards [3][4] | |||||||||
| Building Placement/Required Perimeter Landscaping | |||||||||
| A | Frontage Buildout (min) | 50% | 60% | 70% | |||||
| B | Road Setback (min) | 10'/A | 10'/A | 10'/A | |||||
| C | Other Property Lines Setback (min) | 10'/A | 10'/A | 10'/A | |||||
| Building Height | |||||||||
| D | Height (min/max) | --/45' | 30'/75' [5] | 30'/150' | |||||
| Parking | |||||||||
| E | Parking Location |
|
|
| |||||
| F | Parking Lot Setback (min)/Required Perimeter Landscaping [3][6][7] | 10'/A | 10'/A | 10'/A | |||||
| Utilities | |||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | Required | |||||
Notes:
| |||||||||
| Table 19.2-18.1, Mixed-Use Center (MU) Lot and Building Standards [1] | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| ' = feet | |||||||||
| Development | Base | Option 1 | Option 2 | ||||||
| Key | Category | Neighborhood | Community | Regional | |||||
Gross Floor Area Ratio [2] - Commercial (min)/Residential (max) | 15%/85% | 15%/85% | 15%/85% | ||||||
| Amenity Space (min) | 10% | 10% | 10% | ||||||
| Strategic Amenity Space (min) | 30% of required AS | 50% of required AS | 75% of required AS | ||||||
| Building Standards [3][4] | |||||||||
| Building Placement/Required Perimeter Landscaping | |||||||||
| A | Frontage Buildout (min) | 50% | 60% | 70% | |||||
| B | Road Setback (min) | 10'/A | 10'/A | 10'/A | |||||
| C | Other Property Lines Setback (min) | 10'/A | 10'/A | 10'/A | |||||
| Building Height | |||||||||
| D | Height (min/max) | --/45' | 30'/75' [5] | 30'/150' | |||||
| Parking | |||||||||
| E | Parking Location |
|
|
| |||||
| F | Parking Lot Setback (min)/Required Perimeter Landscaping [3][6][7] | 10'/A | 10'/A | 10'/A | |||||
| Utilities | |||||||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | Required | |||||
Notes:
| |||||||||
| Figure 19.2-18.1, MU Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-18.1, MU Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-18.1, MU Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Figure 19.2-18.1, MU Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Option 2 |
![]() |
![]() |
![]() |
| Provisions Related to the MU District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Amenity Space | Sec. 19.2-34 |
| Buffers | Sec. 19.2-35 |
| Building Design | Sec. 19.2-36 |
| Landscaping and Screening | Sec. 19.2-41 |
| Exterior Lighting | Sec. 19.2-38 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
Purpose. The Employment Center (EC) District provides for a freestanding employment use or a larger-scale business park. The EC District is oriented toward professional and administrative offices, research and technology, and light industrial uses that operate within the confines of their building and do not have outdoor display or storage. The uses within an employment center may range from corporate headquarters to multi-tenant office buildings, educational and institutional facilities, medical uses, overnight accommodations, finished goods production and assembly, and other related uses. These uses, by virtue of the use types and design standards, should be mutually harmonious with other businesses, as well as with residential, commercial, and other uses permitted in nearby districts. Development within the district emphasizes architectural, aesthetic, and environmental considerations.
Applicability. The EC District should be used to implement the areas shown in the Comprehensive Plan as Office/Light Production and Assembly. Properties within this district are located where negative impacts on the surrounding transportation system and environmental resources are minimized, the uses are compatible with surrounding development, and the intensity of the project is consistent with the Comprehensive Plan. Displayed in Figure 19.2-19.1, EC Illustrated Renderings, are graphic depictions of the lot and building standards. The standards in Table 19.2-19.1, EC Lot and Building Standards, reflect a base pattern and one option:
| Table 19.2-19.1, Employment Center (EC) Lot and Building Standards | ||||
|---|---|---|---|---|
' = feet | ||||
| Development | Base | Option 1 | ||
| Key | Category | Freestanding | Business Park | |
| -- | Amenity Space (min) | -- | 5% | |
| Strategic Amenity Space (min) | -- | 15% of required AS | ||
| Building Standards | ||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||
| A | Road Setback (min) -Arterial Road -Collector/Local Road -Internal Road |
50'/C 25'/B -- |
50'/C 25'/B 10'/A | |
| B | Other Property Lines Setback (min) | 10'/B | 10'/B | |
| Building Height | ||||
| C | Height (max) [1] | 60' [2] | 150' | |
| Parking | ||||
| D | Parking Location |
|
| |
| Utilities | ||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | |
Notes:
| ||||
| Table 19.2-19.1, Employment Center (EC) Lot and Building Standards | ||||
|---|---|---|---|---|
' = feet | ||||
| Development | Base | Option 1 | ||
| Key | Category | Freestanding | Business Park | |
| -- | Amenity Space (min) | -- | 5% | |
| Strategic Amenity Space (min) | -- | 15% of required AS | ||
| Building Standards | ||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||
| A | Road Setback (min) -Arterial Road -Collector/Local Road -Internal Road |
50'/C 25'/B -- |
50'/C 25'/B 10'/A | |
| B | Other Property Lines Setback (min) | 10'/B | 10'/B | |
| Building Height | ||||
| C | Height (max) [1] | 60' [2] | 150' | |
| Parking | ||||
| D | Parking Location |
|
| |
| Utilities | ||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | |
Notes:
| ||||
| Table 19.2-19.1, Employment Center (EC) Lot and Building Standards | ||||
|---|---|---|---|---|
' = feet | ||||
| Development | Base | Option 1 | ||
| Key | Category | Freestanding | Business Park | |
| -- | Amenity Space (min) | -- | 5% | |
| Strategic Amenity Space (min) | -- | 15% of required AS | ||
| Building Standards | ||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||
| A | Road Setback (min) -Arterial Road -Collector/Local Road -Internal Road |
50'/C 25'/B -- |
50'/C 25'/B 10'/A | |
| B | Other Property Lines Setback (min) | 10'/B | 10'/B | |
| Building Height | ||||
| C | Height (max) [1] | 60' [2] | 150' | |
| Parking | ||||
| D | Parking Location |
|
| |
| Utilities | ||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | |
Notes:
| ||||
| Table 19.2-19.1, Employment Center (EC) Lot and Building Standards | ||||
|---|---|---|---|---|
' = feet | ||||
| Development | Base | Option 1 | ||
| Key | Category | Freestanding | Business Park | |
| -- | Amenity Space (min) | -- | 5% | |
| Strategic Amenity Space (min) | -- | 15% of required AS | ||
| Building Standards | ||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||
| A | Road Setback (min) -Arterial Road -Collector/Local Road -Internal Road |
50'/C 25'/B -- |
50'/C 25'/B 10'/A | |
| B | Other Property Lines Setback (min) | 10'/B | 10'/B | |
| Building Height | ||||
| C | Height (max) [1] | 60' [2] | 150' | |
| Parking | ||||
| D | Parking Location |
|
| |
| Utilities | ||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | |
Notes:
| ||||
| Figure 19.2-19.1, EC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-19.1, EC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-19.1, EC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-19.1, EC Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Provisions Related to the EC District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Amenity Space | Sec. 19.2-34 |
| Buffers | Sec. 19.2-35 |
| Building Design | Sec. 19.2-36 |
| Landscaping and Screening | Sec. 19.2-41 |
| Exterior Lighting | Sec. 19.2-38 |
| Parkin | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
Purpose. The Employment General (EG) District provides for larger and more intense land uses that may be located on individual parcels or on a lot within an employment park. The uses within this district may involve medium to heavy manufacturing, special trade contractors, equipment sales and service, welding and machine fabrication, materials handling, and ancillary storage and transportation uses. By the nature and scale of these operations, there are expected concerns associated with peak hour employee traffic and potential impacts of light, noise, dust, vibration, odor, outside storage, or business activities. The heavy commercial and industrial activities in this district must be abated by site and building design and environmental performance standards to mitigate the impacts.
| Table 19.2-20, Employment General (EG) Lot, Building, and Transition Standards | ||||
|---|---|---|---|---|
| ' = feet | ||||
| Development | Base | Option 1 | ||
| Key | Category | Freestanding | Employment Park | |
| -- | Amenity Space (min) | -- | -- | |
| Building Standards | ||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||
| A | Road Setback (min) - Arterial Road - Collector/Local Road - Internal Road |
75'/C 60'/C -- |
75'/C 60'/C 25'/C | |
| B | Other Property Lines Setback (min) | 20'/B | 20'/B [1] | |
| Building Height | ||||
| C | Height (max) [2] | 150' | 150' | |
| Parking | ||||
| D | Parking Location |
|
| |
| Utilities | ||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | |
Notes: [1] Setbacks may be reduced to zero feet where adjacent property is zoned EG. [2] Within 200 feet of a developed residential neighborhood, the height shall not exceed 60'. Maximum height can equal the height of a residential structure within 100' of the common boundary if greater than 60'. | ||||
| Table 19.2-20, Employment General (EG) Lot, Building, and Transition Standards | ||||
|---|---|---|---|---|
| ' = feet | ||||
| Development | Base | Option 1 | ||
| Key | Category | Freestanding | Employment Park | |
| -- | Amenity Space (min) | -- | -- | |
| Building Standards | ||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||
| A | Road Setback (min) - Arterial Road - Collector/Local Road - Internal Road |
75'/C 60'/C -- |
75'/C 60'/C 25'/C | |
| B | Other Property Lines Setback (min) | 20'/B | 20'/B [1] | |
| Building Height | ||||
| C | Height (max) [2] | 150' | 150' | |
| Parking | ||||
| D | Parking Location |
|
| |
| Utilities | ||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | |
Notes: [1] Setbacks may be reduced to zero feet where adjacent property is zoned EG. [2] Within 200 feet of a developed residential neighborhood, the height shall not exceed 60'. Maximum height can equal the height of a residential structure within 100' of the common boundary if greater than 60'. | ||||
| Table 19.2-20, Employment General (EG) Lot, Building, and Transition Standards | ||||
|---|---|---|---|---|
| ' = feet | ||||
| Development | Base | Option 1 | ||
| Key | Category | Freestanding | Employment Park | |
| -- | Amenity Space (min) | -- | -- | |
| Building Standards | ||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||
| A | Road Setback (min) - Arterial Road - Collector/Local Road - Internal Road |
75'/C 60'/C -- |
75'/C 60'/C 25'/C | |
| B | Other Property Lines Setback (min) | 20'/B | 20'/B [1] | |
| Building Height | ||||
| C | Height (max) [2] | 150' | 150' | |
| Parking | ||||
| D | Parking Location |
|
| |
| Utilities | ||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | |
Notes: [1] Setbacks may be reduced to zero feet where adjacent property is zoned EG. [2] Within 200 feet of a developed residential neighborhood, the height shall not exceed 60'. Maximum height can equal the height of a residential structure within 100' of the common boundary if greater than 60'. | ||||
| Table 19.2-20, Employment General (EG) Lot, Building, and Transition Standards | ||||
|---|---|---|---|---|
| ' = feet | ||||
| Development | Base | Option 1 | ||
| Key | Category | Freestanding | Employment Park | |
| -- | Amenity Space (min) | -- | -- | |
| Building Standards | ||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||
| A | Road Setback (min) - Arterial Road - Collector/Local Road - Internal Road |
75'/C 60'/C -- |
75'/C 60'/C 25'/C | |
| B | Other Property Lines Setback (min) | 20'/B | 20'/B [1] | |
| Building Height | ||||
| C | Height (max) [2] | 150' | 150' | |
| Parking | ||||
| D | Parking Location |
|
| |
| Utilities | ||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | |
Notes: [1] Setbacks may be reduced to zero feet where adjacent property is zoned EG. [2] Within 200 feet of a developed residential neighborhood, the height shall not exceed 60'. Maximum height can equal the height of a residential structure within 100' of the common boundary if greater than 60'. | ||||
| Figure 19.2-20.1, EG Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-20.1, EG Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-20.1, EG Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-20.1, EG Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Provisions Related to the EG District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Amenity Space | Sec. 19.2-34 |
| Buffers | Sec. 19.2-35 |
| Building Design | Sec. 19.2-36 |
| Landscaping and Screening | Sec. 19.2-41 |
| Exterior Lighting | Sec. 19.2-38 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
Purpose. The Warehouse and Distribution (WD) District provides for development of warehouse, outdoor storage, distribution, trucking, and related uses, facilities, and operations. The amount of land, building floor area, and volume of shipping, receiving and heavy truck traffic warrants site locations in proximity to rail or water transportation and limited access highways. This district should be located away from residential uses and primary and secondary schools to avoid the common issues and impacts of these uses. This district necessitates development standards to address high volumes of truck traffic and compatibility with less intense zoning districts that share a common boundary.
| Table 19.2-21.1, Warehouse and Distribution (WD) Lot, Building, and Transition Standards | ||||
|---|---|---|---|---|
| ' = feet | ||||
| Development | Base | Option 1 | ||
| Key | Category | Freestanding | Warehouse Park | |
| -- | Amenity Space (min) | -- | -- | |
| Building Standards | ||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||
| A | Road - Arterial Road - Collector/Local Road - Internal Road |
75'/C 60'/C -- |
75'/C 75'/C 10'/A | |
| B | Other Property Lines Setback (min) | 20'/B | 20'/B | |
| Building Height | ||||
| C | Height (max) [1] | 150' | 150' | |
| Parking | ||||
| D | Parking Location |
|
| |
| Utilities | ||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | |
Notes:
| ||||
| Table 19.2-21.1, Warehouse and Distribution (WD) Lot, Building, and Transition Standards | ||||
|---|---|---|---|---|
| ' = feet | ||||
| Development | Base | Option 1 | ||
| Key | Category | Freestanding | Warehouse Park | |
| -- | Amenity Space (min) | -- | -- | |
| Building Standards | ||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||
| A | Road - Arterial Road - Collector/Local Road - Internal Road |
75'/C 60'/C -- |
75'/C 75'/C 10'/A | |
| B | Other Property Lines Setback (min) | 20'/B | 20'/B | |
| Building Height | ||||
| C | Height (max) [1] | 150' | 150' | |
| Parking | ||||
| D | Parking Location |
|
| |
| Utilities | ||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | |
Notes:
| ||||
| Table 19.2-21.1, Warehouse and Distribution (WD) Lot, Building, and Transition Standards | ||||
|---|---|---|---|---|
| ' = feet | ||||
| Development | Base | Option 1 | ||
| Key | Category | Freestanding | Warehouse Park | |
| -- | Amenity Space (min) | -- | -- | |
| Building Standards | ||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||
| A | Road - Arterial Road - Collector/Local Road - Internal Road |
75'/C 60'/C -- |
75'/C 75'/C 10'/A | |
| B | Other Property Lines Setback (min) | 20'/B | 20'/B | |
| Building Height | ||||
| C | Height (max) [1] | 150' | 150' | |
| Parking | ||||
| D | Parking Location |
|
| |
| Utilities | ||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | |
Notes:
| ||||
| Table 19.2-21.1, Warehouse and Distribution (WD) Lot, Building, and Transition Standards | ||||
|---|---|---|---|---|
| ' = feet | ||||
| Development | Base | Option 1 | ||
| Key | Category | Freestanding | Warehouse Park | |
| -- | Amenity Space (min) | -- | -- | |
| Building Standards | ||||
| Building and Parking Setbacks/Required Perimeter Landscaping | ||||
| A | Road - Arterial Road - Collector/Local Road - Internal Road |
75'/C 60'/C -- |
75'/C 75'/C 10'/A | |
| B | Other Property Lines Setback (min) | 20'/B | 20'/B | |
| Building Height | ||||
| C | Height (max) [1] | 150' | 150' | |
| Parking | ||||
| D | Parking Location |
|
| |
| Utilities | ||||
| -- | Use of Public Water and/or Wastewater Systems for Development Approved after January 1, 2026. | Required | Required | |
Notes:
| ||||
| Figure 19.2-21.1, WD Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-21.1, WD Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-21.1, WD Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Figure 19.2-21.1, WD Illustrated Renderings |
|---|
| Base |
![]() |
![]() |
![]() |
| Option 1 |
![]() |
![]() |
![]() |
| Provisions Related to the WD District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Amenity Space | Sec. 19.2-34 |
| Buffers | Sec. 19.2-35 |
| Building Design | Sec. 19.2-36 |
| Landscaping and Screening | Sec. 19.2-41 |
| Exterior Lighting | Sec. 19.2-38 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
Purpose. The Village Overlay (VO) District protects the County's historic villages and other unique mixed-use areas, including Bon Air, Chester, Ettrick, Matoaca, Midlothian, and Rockwood.
| Figure 19.2-22.1, Village Overlay Map | |
|---|---|
|
| Table 19.2-22.1 Village Overlay (VO) Lot and Building Standards [1] | ||||
|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||
| Development | ||||
| Key | Category | Standard | ||
| A | Amenity Space (min) | 10% | ||
| Strategic Amenity Space (min) | 75% | |||
| Building Standards | ||||
| Building Setbacks /Required Perimeter Landscaping | ||||
| Road Type | ||||
| B | Limited Access (min) | 40'/C | ||
| C | Arterial/Other (min) | 10’/A | ||
| Interior Side Yard [2] | ||||
| D | Adjacent to Residential Districts (min) | 10’/B | ||
| E | Nonresidential use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 0' | ||
| F | Multifamily use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10'/B | ||
| Rear Yard [2] | ||||
| G | Adjacent to Residential Districts (min) | 10’/B | ||
| H | Nonresidential use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 0' | ||
| I | Multifamily use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10'/B | ||
| Parking Setbacks (feet)/Required Perimeter Landscaping | ||||
| Road Type | ||||
| J | Limited Access (min) | 40'/C | ||
| K | Arterial/Other (min) | No closer to road than building face/B [3] | ||
| Interior Side Yard and Rear Yard | ||||
| L | All developments (min) | 10’/B [3,4] | ||
| Building Height | ||||
| Generally | ||||
| M | Height (min), building fronting arterial roads | 30' | ||
| N | Height (max), generally [5] [6] | 70' | ||
| O | Height (max), within 100' of arterial road or property zoned or used for single-family detached dwellings | 45' | ||
Notes:
| ||||
| Table 19.2-22.1 Village Overlay (VO) Lot and Building Standards [1] | ||||
|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||
| Development | ||||
| Key | Category | Standard | ||
| A | Amenity Space (min) | 10% | ||
| Strategic Amenity Space (min) | 75% | |||
| Building Standards | ||||
| Building Setbacks /Required Perimeter Landscaping | ||||
| Road Type | ||||
| B | Limited Access (min) | 40'/C | ||
| C | Arterial/Other (min) | 10’/A | ||
| Interior Side Yard [2] | ||||
| D | Adjacent to Residential Districts (min) | 10’/B | ||
| E | Nonresidential use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 0' | ||
| F | Multifamily use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10'/B | ||
| Rear Yard [2] | ||||
| G | Adjacent to Residential Districts (min) | 10’/B | ||
| H | Nonresidential use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 0' | ||
| I | Multifamily use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10'/B | ||
| Parking Setbacks (feet)/Required Perimeter Landscaping | ||||
| Road Type | ||||
| J | Limited Access (min) | 40'/C | ||
| K | Arterial/Other (min) | No closer to road than building face/B [3] | ||
| Interior Side Yard and Rear Yard | ||||
| L | All developments (min) | 10’/B [3,4] | ||
| Building Height | ||||
| Generally | ||||
| M | Height (min), building fronting arterial roads | 30' | ||
| N | Height (max), generally [5] [6] | 70' | ||
| O | Height (max), within 100' of arterial road or property zoned or used for single-family detached dwellings | 45' | ||
Notes:
| ||||
| Table 19.2-22.1 Village Overlay (VO) Lot and Building Standards [1] | ||||
|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||
| Development | ||||
| Key | Category | Standard | ||
| A | Amenity Space (min) | 10% | ||
| Strategic Amenity Space (min) | 75% | |||
| Building Standards | ||||
| Building Setbacks /Required Perimeter Landscaping | ||||
| Road Type | ||||
| B | Limited Access (min) | 40'/C | ||
| C | Arterial/Other (min) | 10’/A | ||
| Interior Side Yard [2] | ||||
| D | Adjacent to Residential Districts (min) | 10’/B | ||
| E | Nonresidential use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 0' | ||
| F | Multifamily use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10'/B | ||
| Rear Yard [2] | ||||
| G | Adjacent to Residential Districts (min) | 10’/B | ||
| H | Nonresidential use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 0' | ||
| I | Multifamily use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10'/B | ||
| Parking Setbacks (feet)/Required Perimeter Landscaping | ||||
| Road Type | ||||
| J | Limited Access (min) | 40'/C | ||
| K | Arterial/Other (min) | No closer to road than building face/B [3] | ||
| Interior Side Yard and Rear Yard | ||||
| L | All developments (min) | 10’/B [3,4] | ||
| Building Height | ||||
| Generally | ||||
| M | Height (min), building fronting arterial roads | 30' | ||
| N | Height (max), generally [5] [6] | 70' | ||
| O | Height (max), within 100' of arterial road or property zoned or used for single-family detached dwellings | 45' | ||
Notes:
| ||||
| Table 19.2-22.1 Village Overlay (VO) Lot and Building Standards [1] | ||||
|---|---|---|---|---|
| ac = acre du = dwelling unit sf. = square feet ' = feet | ||||
| Development | ||||
| Key | Category | Standard | ||
| A | Amenity Space (min) | 10% | ||
| Strategic Amenity Space (min) | 75% | |||
| Building Standards | ||||
| Building Setbacks /Required Perimeter Landscaping | ||||
| Road Type | ||||
| B | Limited Access (min) | 40'/C | ||
| C | Arterial/Other (min) | 10’/A | ||
| Interior Side Yard [2] | ||||
| D | Adjacent to Residential Districts (min) | 10’/B | ||
| E | Nonresidential use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 0' | ||
| F | Multifamily use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10'/B | ||
| Rear Yard [2] | ||||
| G | Adjacent to Residential Districts (min) | 10’/B | ||
| H | Nonresidential use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 0' | ||
| I | Multifamily use adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10'/B | ||
| Parking Setbacks (feet)/Required Perimeter Landscaping | ||||
| Road Type | ||||
| J | Limited Access (min) | 40'/C | ||
| K | Arterial/Other (min) | No closer to road than building face/B [3] | ||
| Interior Side Yard and Rear Yard | ||||
| L | All developments (min) | 10’/B [3,4] | ||
| Building Height | ||||
| Generally | ||||
| M | Height (min), building fronting arterial roads | 30' | ||
| N | Height (max), generally [5] [6] | 70' | ||
| O | Height (max), within 100' of arterial road or property zoned or used for single-family detached dwellings | 45' | ||
Notes:
| ||||
Excluding the area for windows and doors, a minimum of 50% of the façade of the first two stories of a building fronting a road or containing a public entrance visible from a road shall be faced with stone, brick, or other masonry material similar in appearance to stone or brick.
Storefront Windows & Pedestrian Entrances. The first floor of any building façade facing a public road or common area shall incorporate storefront windows and pedestrian entrances that connect directly to the sidewalk along the road, or to a sidewalk that connects to the sidewalk along the road. Windows or pedestrian entrances shall be spaced a maximum of 10 linear feet along the front façade.
| Table 19.2-22.2 Pedestrian and Bicycle Network Proposed Improvements Summary | ||
|---|---|---|
| Road/Location | Facility Type [1] | Side of Road |
| Midlothian Turnpike | Sidewalk - Minimum 6' | North Side |
| Midlothian Turnpike | Shared Use Path | South Side |
| Woolridge Road | Bike Land and Sidewalk (existing) | Both |
| Charter Colony Parkway | Shared Use Path | East Side |
| Coalfield | Sidewalk - Minimum 5' | Both |
| Winterfield | Sidewalk - Minimum 5' | Both |
| Westfield | Bike Lane and Sidewalk | Both |
| Other/New Roads | As identified in the Infrastructure Plan Section of the Midlothian Community Special Area Plan | |
Notes:
| ||
| Table 19.2-22.2 Pedestrian and Bicycle Network Proposed Improvements Summary | ||
|---|---|---|
| Road/Location | Facility Type [1] | Side of Road |
| Midlothian Turnpike | Sidewalk - Minimum 6' | North Side |
| Midlothian Turnpike | Shared Use Path | South Side |
| Woolridge Road | Bike Land and Sidewalk (existing) | Both |
| Charter Colony Parkway | Shared Use Path | East Side |
| Coalfield | Sidewalk - Minimum 5' | Both |
| Winterfield | Sidewalk - Minimum 5' | Both |
| Westfield | Bike Lane and Sidewalk | Both |
| Other/New Roads | As identified in the Infrastructure Plan Section of the Midlothian Community Special Area Plan | |
Notes:
| ||
| Table 19.2-22.2 Pedestrian and Bicycle Network Proposed Improvements Summary | ||
|---|---|---|
| Road/Location | Facility Type [1] | Side of Road |
| Midlothian Turnpike | Sidewalk - Minimum 6' | North Side |
| Midlothian Turnpike | Shared Use Path | South Side |
| Woolridge Road | Bike Land and Sidewalk (existing) | Both |
| Charter Colony Parkway | Shared Use Path | East Side |
| Coalfield | Sidewalk - Minimum 5' | Both |
| Winterfield | Sidewalk - Minimum 5' | Both |
| Westfield | Bike Lane and Sidewalk | Both |
| Other/New Roads | As identified in the Infrastructure Plan Section of the Midlothian Community Special Area Plan | |
Notes:
| ||
| Table 19.2-22.2 Pedestrian and Bicycle Network Proposed Improvements Summary | ||
|---|---|---|
| Road/Location | Facility Type [1] | Side of Road |
| Midlothian Turnpike | Sidewalk - Minimum 6' | North Side |
| Midlothian Turnpike | Shared Use Path | South Side |
| Woolridge Road | Bike Land and Sidewalk (existing) | Both |
| Charter Colony Parkway | Shared Use Path | East Side |
| Coalfield | Sidewalk - Minimum 5' | Both |
| Winterfield | Sidewalk - Minimum 5' | Both |
| Westfield | Bike Lane and Sidewalk | Both |
| Other/New Roads | As identified in the Infrastructure Plan Section of the Midlothian Community Special Area Plan | |
Notes:
| ||
Exterior Lighting.
Streetlights. Along sidewalks adjacent to roads, pedestrian-scale streetlights shall be designed to enhance the pedestrian character of the district, spaced generally 60 feet on center and have fixture mounting heights between 12 and 15 feet above finished grade. New fixtures shall be compatible with existing fixtures within the district.
| Provisions Related to the Village Overlay District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Amenity Space | Sec. 19.2-34 |
| Buffers | Sec. 19.2-35 |
| Building Design | Sec. 19.2-36 |
| Dimensional Standards | Sec. 19.2-37 |
| Landscaping and Screening | Sec. 19.2-41 |
| Exterior Lighting | Sec. 19.2-38 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
Purpose. The Urban Corridor Overlay (UCO) District protects and enhances development along the Route 1, 10, 60, and 360 Highways in Chesterfield County. The UCO District standards:
| Figure 19.2-23.1, Urban Corridor Overlay (UCO) Maps | |
|---|---|
![]() ![]() |
| Table 19.2-23.1 Urban Corridor Overlay (UCO) Lot and Building Standards | ||||
|---|---|---|---|---|
| ' = feet | ||||
| Development | ||||
| Key | Category | Standard | ||
| A | Amenity Space (min) | 5% | ||
| Strategic Amenity Space (min) | 50% | |||
| Building Standards | ||||
| Building Setbacks (feet)/Required Perimeter Landscaping Type | ||||
| Road Type | ||||
| B | Limited Access (min) | 40'/C | ||
| C | Arterial/Other (min) | 15’/A | ||
| Interior Side Yard | ||||
| D | Adjacent to Residential Districts (min) | 10’/B | ||
| E | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 5' | ||
| Rear Yard | ||||
| J | Adjacent to Residential Districts (min) | 20’/B | ||
| K | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 5' | ||
| Parking Setbacks (feet)/Required Perimeter Landscaping | ||||
| Road Type | ||||
| L | Limited Access (min) | 40'/C | ||
| M | Arterial (min) | 15’/A | ||
| N | Other (min) | 15’/A | ||
| Interior Side Yard | ||||
| O | Adjacent to Residential Districts (min) | 15’/B (see buffer requirements) | ||
| P | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10’ [1] | ||
| Rear Yard | ||||
| Q | Adjacent to Residential Districts (min) | 20’/B (see buffer requirements) | ||
| R | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10' | ||
| Building Height | ||||
| Generally | ||||
| T | Height (max) | See Zoning District [2] | ||
| Buildings containing residential uses | ||||
| W | Height (max), within 50' of arterial road or 200' of a developed residential neighborhood | 45' [3] | ||
Notes:
| ||||
| Table 19.2-23.1 Urban Corridor Overlay (UCO) Lot and Building Standards | ||||
|---|---|---|---|---|
| ' = feet | ||||
| Development | ||||
| Key | Category | Standard | ||
| A | Amenity Space (min) | 5% | ||
| Strategic Amenity Space (min) | 50% | |||
| Building Standards | ||||
| Building Setbacks (feet)/Required Perimeter Landscaping Type | ||||
| Road Type | ||||
| B | Limited Access (min) | 40'/C | ||
| C | Arterial/Other (min) | 15’/A | ||
| Interior Side Yard | ||||
| D | Adjacent to Residential Districts (min) | 10’/B | ||
| E | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 5' | ||
| Rear Yard | ||||
| J | Adjacent to Residential Districts (min) | 20’/B | ||
| K | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 5' | ||
| Parking Setbacks (feet)/Required Perimeter Landscaping | ||||
| Road Type | ||||
| L | Limited Access (min) | 40'/C | ||
| M | Arterial (min) | 15’/A | ||
| N | Other (min) | 15’/A | ||
| Interior Side Yard | ||||
| O | Adjacent to Residential Districts (min) | 15’/B (see buffer requirements) | ||
| P | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10’ [1] | ||
| Rear Yard | ||||
| Q | Adjacent to Residential Districts (min) | 20’/B (see buffer requirements) | ||
| R | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10' | ||
| Building Height | ||||
| Generally | ||||
| T | Height (max) | See Zoning District [2] | ||
| Buildings containing residential uses | ||||
| W | Height (max), within 50' of arterial road or 200' of a developed residential neighborhood | 45' [3] | ||
Notes:
| ||||
| Table 19.2-23.1 Urban Corridor Overlay (UCO) Lot and Building Standards | ||||
|---|---|---|---|---|
| ' = feet | ||||
| Development | ||||
| Key | Category | Standard | ||
| A | Amenity Space (min) | 5% | ||
| Strategic Amenity Space (min) | 50% | |||
| Building Standards | ||||
| Building Setbacks (feet)/Required Perimeter Landscaping Type | ||||
| Road Type | ||||
| B | Limited Access (min) | 40'/C | ||
| C | Arterial/Other (min) | 15’/A | ||
| Interior Side Yard | ||||
| D | Adjacent to Residential Districts (min) | 10’/B | ||
| E | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 5' | ||
| Rear Yard | ||||
| J | Adjacent to Residential Districts (min) | 20’/B | ||
| K | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 5' | ||
| Parking Setbacks (feet)/Required Perimeter Landscaping | ||||
| Road Type | ||||
| L | Limited Access (min) | 40'/C | ||
| M | Arterial (min) | 15’/A | ||
| N | Other (min) | 15’/A | ||
| Interior Side Yard | ||||
| O | Adjacent to Residential Districts (min) | 15’/B (see buffer requirements) | ||
| P | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10’ [1] | ||
| Rear Yard | ||||
| Q | Adjacent to Residential Districts (min) | 20’/B (see buffer requirements) | ||
| R | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10' | ||
| Building Height | ||||
| Generally | ||||
| T | Height (max) | See Zoning District [2] | ||
| Buildings containing residential uses | ||||
| W | Height (max), within 50' of arterial road or 200' of a developed residential neighborhood | 45' [3] | ||
Notes:
| ||||
| Table 19.2-23.1 Urban Corridor Overlay (UCO) Lot and Building Standards | ||||
|---|---|---|---|---|
| ' = feet | ||||
| Development | ||||
| Key | Category | Standard | ||
| A | Amenity Space (min) | 5% | ||
| Strategic Amenity Space (min) | 50% | |||
| Building Standards | ||||
| Building Setbacks (feet)/Required Perimeter Landscaping Type | ||||
| Road Type | ||||
| B | Limited Access (min) | 40'/C | ||
| C | Arterial/Other (min) | 15’/A | ||
| Interior Side Yard | ||||
| D | Adjacent to Residential Districts (min) | 10’/B | ||
| E | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 5' | ||
| Rear Yard | ||||
| J | Adjacent to Residential Districts (min) | 20’/B | ||
| K | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 5' | ||
| Parking Setbacks (feet)/Required Perimeter Landscaping | ||||
| Road Type | ||||
| L | Limited Access (min) | 40'/C | ||
| M | Arterial (min) | 15’/A | ||
| N | Other (min) | 15’/A | ||
| Interior Side Yard | ||||
| O | Adjacent to Residential Districts (min) | 15’/B (see buffer requirements) | ||
| P | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10’ [1] | ||
| Rear Yard | ||||
| Q | Adjacent to Residential Districts (min) | 20’/B (see buffer requirements) | ||
| R | Adjacent to Commercial and Mixed-Use or Employment Districts (min) | 10' | ||
| Building Height | ||||
| Generally | ||||
| T | Height (max) | See Zoning District [2] | ||
| Buildings containing residential uses | ||||
| W | Height (max), within 50' of arterial road or 200' of a developed residential neighborhood | 45' [3] | ||
Notes:
| ||||
Exterior Lighting.
Streetlights. Along sidewalks adjacent to roads, pedestrian-scale streetlights shall be designed to enhance the pedestrian character of the district, spaced generally 60 feet on center and have fixture mounting heights between 12 and 15 feet above finished grade. New fixtures shall be compatible with existing fixtures within the district.
| Provisions Related to the Urban Corridor Overlay District | |
| Chesapeake Bay Preservation Areas | Sec. 19.2-26 |
| Floodplain Management Districts | Sec. 19.2-27 |
| Amenity Space | Sec. 19.2-34 |
| Buffers | Sec. 19.2-35 |
| Building Design | Sec. 19.2-36 |
| Dimensional Standards | Sec. 19.2-37 |
| Landscaping and Screening | Sec. 19.2-41 |
| Exterior Lighting | Sec. 19.2-38 |
| Parking | Sec. 19.2-42 |
| Streets, Transportation, and Connectivity | Sec. 19.2-45 |
Purpose: The Roseland Zoning Overlay (RZO) District provides for a high-quality master- planned mixed-use community. It is the intent of this District to allow for flexibility while maintaining the high-quality development concepts envisioned by the approved Roseland rezoning (Zoning Case 07SN0223) along with the guiding principles as set forth below:
The provisions of this district shall not supersede the approved conditions of Zoning Case 07SN0223. Upon adoption, zoning approval for individual ownership tracts may be obtained, with more specific land uses and design details being provided for each development tract. Any rezoning request submitted on property located within the RZO boundaries shall comply with the standards provided herein and as otherwise required by the Chesterfield County Zoning Ordinance, unless otherwise granted by the Chesterfield County Board of Supervisors where such approval would advance the guiding principles above. Once rezoning is granted on an individual development tract, the conditions of Zoning Case 07SN0223 shall be null and void within such tract.
That this ordinance shall become effective immediately after adoption.
The RZO is comprised of the following area as shown on the zoning maps, and as shaded in Figure 19.2-24.1.:
| Figure: 19.2-24.1. |
![]() |
The purpose of the Master Plan is to serve as a conceptual development guide for the RZO. The Master Plan is general in nature and provides for flexibility of overall uses while depicting desirable locations for higher-density and/or mixed-use nodes throughout the RZO, as well as flexibility for road alignments throughout individual projects so long as connection points to adjoining roads and/or parcels are in the general locations illustrated in the Master Plan below. The locations of specific uses shall be determined at the time of rezoning and plans review, or as otherwise required by the Zoning Ordinance through Schematic Plan approval. The Master Plan is displayed in Figure 19.2-24.2.:
| Figure: 19.2-24.2. |
![]() |
The RZO shall be comprised of the following Use Districts, as depicted in Figure 19.2-24.3. below. Descriptions of these Use Districts and their permitted uses are provided as follows in subsection D through G.
| Figure: 19.2-24.3. |
![]() |
The purpose of the Suburban Residential District is to provide for lower density detached single-family dwelling development comparable to that found in the Hallsley community. Uses permitted in this district shall be limited to those permitted within the SC District, subject to the standards provided in Section 19.2-24.K.1. and 19.2-24.K.4.
| Table: 19.2-24.1. | |||||
| Development Tracts | Acreage (approx.) | Single‐Family | Townhome (and similar attached units) | Multi‐Family (apartment/condo) | Non‐Residential |
| Tract A | 777.5 total | ||||
| A.1. East of Woolridge Rd. | 326.6 | 300 | 300 | 500 | 500,000 |
| A.2. North Hallsley | 302.5 | 340 | 0 | 0 | 0 |
| A.3. West of Woolridge Rd./east of Otterdale Rd. | 42.3 | 0 | 0 | 250 | 30,000 |
| A.4. North of Old Hundred Rd. | 106.1 | 80 | 120 | 250 | 30,000 |
| Tract B | |||||
| 272.5 | 333 | 333 | 333 | 60,000 | |
| Tract C | |||||
| Note: Max. 200 dwelling units on this Tract | 95.4 | 200 | Max. 50 of the 200 units | Max. 50 of the 200 units | 15,000 |
| Tract D | |||||
| Note: Max. 525 dwelling units on this Tract | 117 | Max. 100 of the 525 units | 325 | 200 | 180,000 |
| Tract E | |||||
| 115.2 | 0 | 237 | 168 | 0 | |
| Tract F | |||||
| 30.2 | 91 | OR 240 | 0 | 0 | |
| Tract G | |||||
| Public Facilities Only | 81.5 | 0 | 0 | 0 | 0 |
| Totals | 1489.3 | 4,509 total residential units | 815,000 total sq. ft. | ||
![]() | |||||
Figure 19.2-24.4. below shows the conceptual routing of roads (arterial, collector and local roads) within the RZO. The alignments of the major roads would connect to adjacent roads and/or neighboring projects in the general locations illustrated in the figure below. Otherwise, these routes are general in nature and depict a hierarchy of street types in order to support the desired development pattern in Roseland. The alignment of each major road within a particular project shall be determined by the property owner(s) during the rezoning and/or plans review process, subject to approval by the Transportation Department. For local roads, the alignment and connection points to other roads shall be determined by the property owner(s) and as approved by the Transportation Department during the rezoning process and/or plans review process, notwithstanding what is shown below.
| Figure: 19.2-24.4. |
![]() |
| Table 19.2-24.2. Required Standards - Street Design | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Street Sections[1] | Details | |||||||||||
| Major Arterials | ||||||||||||
| Section A. | Applicable to Brightwalton Rd. from the current terminus in Hallsley to Mt. Hermon Rd., or for Roseland Ave. between Otterdale Rd. and Old Hundred Rd. | |||||||||||
| Section B.1. | Applicable to any segment of Roseland Ave. and Brightwalton Rd. (non-residential uses may front where acceptable to Director of Planning [2]) | |||||||||||
| Section B.2. (four travel lanes) | Applicable to any segment of Roseland Ave. and Brightwalton Rd. (non-residential uses may front where acceptable to Director of Planning [2]) | |||||||||||
| Section C.1. | Applicable to any segment of Roseland Ave. and Brightwalton Rd./Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Section C.2. (four travel lanes) | Applicable to any segment of Roseland Ave. and Brightwalton Rd./Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Collectors | ||||||||||||
| Section D.1. | Applicable to any Collector where residential uses front | |||||||||||
| Section D.2. | Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Local Streets | ||||||||||||
| Section E.1. | Applicable where residential uses front | |||||||||||
| Section E.2. | Applicable where residential uses front | |||||||||||
| Section E.3. | Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Section F (option for one-way travel) | Mews Street | |||||||||||
| Design Requirements (details) | Street Sections | |||||||||||
| Buildings do not front/buffers required on abutting residential subdivisions | A. | |||||||||||
| Buildings front/residential lots are rear-loaded | B.1. | B.2. | C.1. | C.2. | D.1. | D.2. | E.2. | E.3. | ||||
| Street trees | B.1. | B.2. | C.1. | C.2. | D.1. | D.2. | E.1. | E.2. | E.3. | |||
| Buffer strips (minimum 6 feet wide between back of curb and edge of sidewalk) | B.1. | B.2. | D.1. | E.1. | E.2. | |||||||
| Street tree fixtures such as tree grates, tree wells, or planter boxes | C.1. | C.2. | D.2. | E.3. | ||||||||
| Sidewalks on both sides, except for Roseland Ave., or as otherwise permitted by Section 19.2-24.I.1.d. | A. | C.1. | C.2. | D.1. | D.2. | E.1. | E.2. | E.3. | ||||
| Sidewalk on one side | B.1. | B.2. | F. | |||||||||
| Sidewalks shall extend to the edge of the street curb. Treatment shall consist of a combination of materials such as concrete, brick, or pavers | C.1. | C.2. | D.2. | E.3. | ||||||||
| Shared-use path on one side (optional for Brightwalton Rd.) | A. | B.1. | B.2. | |||||||||
| Sidewalks and shared-use paths may meander through landscaped areas or buffers (outside r.o.w.) | A. | |||||||||||
| On-street parking | C.1. | C.2. | D.1. | D.2. | E.1. | E.2. | E.3. | |||||
| On-street parking clearly identified | C.1. | C.2. | D.1. | D.2. | E.2. | E.3. | ||||||
| Provides road frontage for a maximum of 10 single-family lots | F. | |||||||||||
| Wide median accommodates future phased expansion for additional travel lanes | B.1. | C.1. | ||||||||||
| The Director of Planning may grant flexibility regarding the provision of on-street parking and/or sidewalk improvements where one side of the road is developed for non-residential development and the opposite side is developed for residential or lower-intensity development, or one side of such road abuts a park, common area or environmental feature. The aforementioned improvements may then be applied to one side of such road | C.1. | C.2. | D.1. | D.2. | E.2. | E.3. | ||||||
Notes:
| ||||||||||||
| Table 19.2-24.2. Required Standards - Street Design | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Street Sections[1] | Details | |||||||||||
| Major Arterials | ||||||||||||
| Section A. | Applicable to Brightwalton Rd. from the current terminus in Hallsley to Mt. Hermon Rd., or for Roseland Ave. between Otterdale Rd. and Old Hundred Rd. | |||||||||||
| Section B.1. | Applicable to any segment of Roseland Ave. and Brightwalton Rd. (non-residential uses may front where acceptable to Director of Planning [2]) | |||||||||||
| Section B.2. (four travel lanes) | Applicable to any segment of Roseland Ave. and Brightwalton Rd. (non-residential uses may front where acceptable to Director of Planning [2]) | |||||||||||
| Section C.1. | Applicable to any segment of Roseland Ave. and Brightwalton Rd./Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Section C.2. (four travel lanes) | Applicable to any segment of Roseland Ave. and Brightwalton Rd./Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Collectors | ||||||||||||
| Section D.1. | Applicable to any Collector where residential uses front | |||||||||||
| Section D.2. | Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Local Streets | ||||||||||||
| Section E.1. | Applicable where residential uses front | |||||||||||
| Section E.2. | Applicable where residential uses front | |||||||||||
| Section E.3. | Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Section F (option for one-way travel) | Mews Street | |||||||||||
| Design Requirements (details) | Street Sections | |||||||||||
| Buildings do not front/buffers required on abutting residential subdivisions | A. | |||||||||||
| Buildings front/residential lots are rear-loaded | B.1. | B.2. | C.1. | C.2. | D.1. | D.2. | E.2. | E.3. | ||||
| Street trees | B.1. | B.2. | C.1. | C.2. | D.1. | D.2. | E.1. | E.2. | E.3. | |||
| Buffer strips (minimum 6 feet wide between back of curb and edge of sidewalk) | B.1. | B.2. | D.1. | E.1. | E.2. | |||||||
| Street tree fixtures such as tree grates, tree wells, or planter boxes | C.1. | C.2. | D.2. | E.3. | ||||||||
| Sidewalks on both sides, except for Roseland Ave., or as otherwise permitted by Section 19.2-24.I.1.d. | A. | C.1. | C.2. | D.1. | D.2. | E.1. | E.2. | E.3. | ||||
| Sidewalk on one side | B.1. | B.2. | F. | |||||||||
| Sidewalks shall extend to the edge of the street curb. Treatment shall consist of a combination of materials such as concrete, brick, or pavers | C.1. | C.2. | D.2. | E.3. | ||||||||
| Shared-use path on one side (optional for Brightwalton Rd.) | A. | B.1. | B.2. | |||||||||
| Sidewalks and shared-use paths may meander through landscaped areas or buffers (outside r.o.w.) | A. | |||||||||||
| On-street parking | C.1. | C.2. | D.1. | D.2. | E.1. | E.2. | E.3. | |||||
| On-street parking clearly identified | C.1. | C.2. | D.1. | D.2. | E.2. | E.3. | ||||||
| Provides road frontage for a maximum of 10 single-family lots | F. | |||||||||||
| Wide median accommodates future phased expansion for additional travel lanes | B.1. | C.1. | ||||||||||
| The Director of Planning may grant flexibility regarding the provision of on-street parking and/or sidewalk improvements where one side of the road is developed for non-residential development and the opposite side is developed for residential or lower-intensity development, or one side of such road abuts a park, common area or environmental feature. The aforementioned improvements may then be applied to one side of such road | C.1. | C.2. | D.1. | D.2. | E.2. | E.3. | ||||||
Notes:
| ||||||||||||
| Table 19.2-24.2. Required Standards - Street Design | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Street Sections[1] | Details | |||||||||||
| Major Arterials | ||||||||||||
| Section A. | Applicable to Brightwalton Rd. from the current terminus in Hallsley to Mt. Hermon Rd., or for Roseland Ave. between Otterdale Rd. and Old Hundred Rd. | |||||||||||
| Section B.1. | Applicable to any segment of Roseland Ave. and Brightwalton Rd. (non-residential uses may front where acceptable to Director of Planning [2]) | |||||||||||
| Section B.2. (four travel lanes) | Applicable to any segment of Roseland Ave. and Brightwalton Rd. (non-residential uses may front where acceptable to Director of Planning [2]) | |||||||||||
| Section C.1. | Applicable to any segment of Roseland Ave. and Brightwalton Rd./Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Section C.2. (four travel lanes) | Applicable to any segment of Roseland Ave. and Brightwalton Rd./Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Collectors | ||||||||||||
| Section D.1. | Applicable to any Collector where residential uses front | |||||||||||
| Section D.2. | Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Local Streets | ||||||||||||
| Section E.1. | Applicable where residential uses front | |||||||||||
| Section E.2. | Applicable where residential uses front | |||||||||||
| Section E.3. | Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Section F (option for one-way travel) | Mews Street | |||||||||||
| Design Requirements (details) | Street Sections | |||||||||||
| Buildings do not front/buffers required on abutting residential subdivisions | A. | |||||||||||
| Buildings front/residential lots are rear-loaded | B.1. | B.2. | C.1. | C.2. | D.1. | D.2. | E.2. | E.3. | ||||
| Street trees | B.1. | B.2. | C.1. | C.2. | D.1. | D.2. | E.1. | E.2. | E.3. | |||
| Buffer strips (minimum 6 feet wide between back of curb and edge of sidewalk) | B.1. | B.2. | D.1. | E.1. | E.2. | |||||||
| Street tree fixtures such as tree grates, tree wells, or planter boxes | C.1. | C.2. | D.2. | E.3. | ||||||||
| Sidewalks on both sides, except for Roseland Ave., or as otherwise permitted by Section 19.2-24.I.1.d. | A. | C.1. | C.2. | D.1. | D.2. | E.1. | E.2. | E.3. | ||||
| Sidewalk on one side | B.1. | B.2. | F. | |||||||||
| Sidewalks shall extend to the edge of the street curb. Treatment shall consist of a combination of materials such as concrete, brick, or pavers | C.1. | C.2. | D.2. | E.3. | ||||||||
| Shared-use path on one side (optional for Brightwalton Rd.) | A. | B.1. | B.2. | |||||||||
| Sidewalks and shared-use paths may meander through landscaped areas or buffers (outside r.o.w.) | A. | |||||||||||
| On-street parking | C.1. | C.2. | D.1. | D.2. | E.1. | E.2. | E.3. | |||||
| On-street parking clearly identified | C.1. | C.2. | D.1. | D.2. | E.2. | E.3. | ||||||
| Provides road frontage for a maximum of 10 single-family lots | F. | |||||||||||
| Wide median accommodates future phased expansion for additional travel lanes | B.1. | C.1. | ||||||||||
| The Director of Planning may grant flexibility regarding the provision of on-street parking and/or sidewalk improvements where one side of the road is developed for non-residential development and the opposite side is developed for residential or lower-intensity development, or one side of such road abuts a park, common area or environmental feature. The aforementioned improvements may then be applied to one side of such road | C.1. | C.2. | D.1. | D.2. | E.2. | E.3. | ||||||
Notes:
| ||||||||||||
| Table 19.2-24.2. Required Standards - Street Design | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Street Sections[1] | Details | |||||||||||
| Major Arterials | ||||||||||||
| Section A. | Applicable to Brightwalton Rd. from the current terminus in Hallsley to Mt. Hermon Rd., or for Roseland Ave. between Otterdale Rd. and Old Hundred Rd. | |||||||||||
| Section B.1. | Applicable to any segment of Roseland Ave. and Brightwalton Rd. (non-residential uses may front where acceptable to Director of Planning [2]) | |||||||||||
| Section B.2. (four travel lanes) | Applicable to any segment of Roseland Ave. and Brightwalton Rd. (non-residential uses may front where acceptable to Director of Planning [2]) | |||||||||||
| Section C.1. | Applicable to any segment of Roseland Ave. and Brightwalton Rd./Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Section C.2. (four travel lanes) | Applicable to any segment of Roseland Ave. and Brightwalton Rd./Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Collectors | ||||||||||||
| Section D.1. | Applicable to any Collector where residential uses front | |||||||||||
| Section D.2. | Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Local Streets | ||||||||||||
| Section E.1. | Applicable where residential uses front | |||||||||||
| Section E.2. | Applicable where residential uses front | |||||||||||
| Section E.3. | Required where non-residential uses front/applicable to higher density residential uses | |||||||||||
| Section F (option for one-way travel) | Mews Street | |||||||||||
| Design Requirements (details) | Street Sections | |||||||||||
| Buildings do not front/buffers required on abutting residential subdivisions | A. | |||||||||||
| Buildings front/residential lots are rear-loaded | B.1. | B.2. | C.1. | C.2. | D.1. | D.2. | E.2. | E.3. | ||||
| Street trees | B.1. | B.2. | C.1. | C.2. | D.1. | D.2. | E.1. | E.2. | E.3. | |||
| Buffer strips (minimum 6 feet wide between back of curb and edge of sidewalk) | B.1. | B.2. | D.1. | E.1. | E.2. | |||||||
| Street tree fixtures such as tree grates, tree wells, or planter boxes | C.1. | C.2. | D.2. | E.3. | ||||||||
| Sidewalks on both sides, except for Roseland Ave., or as otherwise permitted by Section 19.2-24.I.1.d. | A. | C.1. | C.2. | D.1. | D.2. | E.1. | E.2. | E.3. | ||||
| Sidewalk on one side | B.1. | B.2. | F. | |||||||||
| Sidewalks shall extend to the edge of the street curb. Treatment shall consist of a combination of materials such as concrete, brick, or pavers | C.1. | C.2. | D.2. | E.3. | ||||||||
| Shared-use path on one side (optional for Brightwalton Rd.) | A. | B.1. | B.2. | |||||||||
| Sidewalks and shared-use paths may meander through landscaped areas or buffers (outside r.o.w.) | A. | |||||||||||
| On-street parking | C.1. | C.2. | D.1. | D.2. | E.1. | E.2. | E.3. | |||||
| On-street parking clearly identified | C.1. | C.2. | D.1. | D.2. | E.2. | E.3. | ||||||
| Provides road frontage for a maximum of 10 single-family lots | F. | |||||||||||
| Wide median accommodates future phased expansion for additional travel lanes | B.1. | C.1. | ||||||||||
| The Director of Planning may grant flexibility regarding the provision of on-street parking and/or sidewalk improvements where one side of the road is developed for non-residential development and the opposite side is developed for residential or lower-intensity development, or one side of such road abuts a park, common area or environmental feature. The aforementioned improvements may then be applied to one side of such road | C.1. | C.2. | D.1. | D.2. | E.2. | E.3. | ||||||
Notes:
| ||||||||||||







| Section E.1. | Section E.2. |
![]() | ![]() |
| Section E.3 | |
![]() |
| Section F. | |
![]() | ![]() |
| Figure: 19.2-24.5 |
![]() |
| Table 19.2-24.3 Required Conditions for Suburban Residential District | ||
|---|---|---|
| Lots | For lots sharing a property boundary with Linear Park | |
| ||
| ||
| 15,000[1] | 11,500 |
| 100 | 70 |
| 30 | 40 |
| ||
| ||
| 30 | 30 |
| 30 | 30 |
| 50 | 50 |
| ||
| ||
| 40 | 40 |
| 25 | 25 |
| 15 (10 to porches) | |
| 15 | 10 (15 when abutting lots are ≥ 15,000 sq. ft. |
| 35 | 30 |
| ||
| 25 | 25 |
| 40 | 40 |
Notes for Table 19.2-24.3
| ||
| Table 19.2-24.3 Required Conditions for Suburban Residential District | ||
|---|---|---|
| Lots | For lots sharing a property boundary with Linear Park | |
| ||
| ||
| 15,000[1] | 11,500 |
| 100 | 70 |
| 30 | 40 |
| ||
| ||
| 30 | 30 |
| 30 | 30 |
| 50 | 50 |
| ||
| ||
| 40 | 40 |
| 25 | 25 |
| 15 (10 to porches) | |
| 15 | 10 (15 when abutting lots are ≥ 15,000 sq. ft. |
| 35 | 30 |
| ||
| 25 | 25 |
| 40 | 40 |
Notes for Table 19.2-24.3
| ||
| Table 19.2-24.3 Required Conditions for Suburban Residential District | ||
|---|---|---|
| Lots | For lots sharing a property boundary with Linear Park | |
| ||
| ||
| 15,000[1] | 11,500 |
| 100 | 70 |
| 30 | 40 |
| ||
| ||
| 30 | 30 |
| 30 | 30 |
| 50 | 50 |
| ||
| ||
| 40 | 40 |
| 25 | 25 |
| 15 (10 to porches) | |
| 15 | 10 (15 when abutting lots are ≥ 15,000 sq. ft. |
| 35 | 30 |
| ||
| 25 | 25 |
| 40 | 40 |
Notes for Table 19.2-24.3
| ||
| Table 19.2-24.3 Required Conditions for Suburban Residential District | ||
|---|---|---|
| Lots | For lots sharing a property boundary with Linear Park | |
| ||
| ||
| 15,000[1] | 11,500 |
| 100 | 70 |
| 30 | 40 |
| ||
| ||
| 30 | 30 |
| 30 | 30 |
| 50 | 50 |
| ||
| ||
| 40 | 40 |
| 25 | 25 |
| 15 (10 to porches) | |
| 15 | 10 (15 when abutting lots are ≥ 15,000 sq. ft. |
| 35 | 30 |
| ||
| 25 | 25 |
| 40 | 40 |
Notes for Table 19.2-24.3
| ||
| Table 19.2-24.4 Required Conditions for Medium-Density Residential with Nodal Mixed-Use District | |
|---|---|
| |
| |
| 5,000 (3,500 when fronting on and having a main/front entrance facing the Linear Park or Amenity Space) |
| 40 |
| 50 |
| |
| |
| 30 |
| 20 |
| 40 |
| |
| |
| 20 (15 to porches) |
| 15 (10 to porches) |
| 10 (5 to porches) |
| 5 |
| 15 |
| |
| 20 |
| 10[5] (rear-loaded) |
| 25 |
| |
| 1 one side[6], 3 one side |
| 5 on each side |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.4
| |
| Table 19.2-24.4 Required Conditions for Medium-Density Residential with Nodal Mixed-Use District | |
|---|---|
| |
| |
| 5,000 (3,500 when fronting on and having a main/front entrance facing the Linear Park or Amenity Space) |
| 40 |
| 50 |
| |
| |
| 30 |
| 20 |
| 40 |
| |
| |
| 20 (15 to porches) |
| 15 (10 to porches) |
| 10 (5 to porches) |
| 5 |
| 15 |
| |
| 20 |
| 10[5] (rear-loaded) |
| 25 |
| |
| 1 one side[6], 3 one side |
| 5 on each side |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.4
| |
| Table 19.2-24.4 Required Conditions for Medium-Density Residential with Nodal Mixed-Use District | |
|---|---|
| |
| |
| 5,000 (3,500 when fronting on and having a main/front entrance facing the Linear Park or Amenity Space) |
| 40 |
| 50 |
| |
| |
| 30 |
| 20 |
| 40 |
| |
| |
| 20 (15 to porches) |
| 15 (10 to porches) |
| 10 (5 to porches) |
| 5 |
| 15 |
| |
| 20 |
| 10[5] (rear-loaded) |
| 25 |
| |
| 1 one side[6], 3 one side |
| 5 on each side |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.4
| |
| Table 19.2-24.4 Required Conditions for Medium-Density Residential with Nodal Mixed-Use District | |
|---|---|
| |
| |
| 5,000 (3,500 when fronting on and having a main/front entrance facing the Linear Park or Amenity Space) |
| 40 |
| 50 |
| |
| |
| 30 |
| 20 |
| 40 |
| |
| |
| 20 (15 to porches) |
| 15 (10 to porches) |
| 10 (5 to porches) |
| 5 |
| 15 |
| |
| 20 |
| 10[5] (rear-loaded) |
| 25 |
| |
| 1 one side[6], 3 one side |
| 5 on each side |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.4
| |
| Table 19.2-24.5 Required Conditions for Commercial/High- Density Residential/Mixed-Use District | |
|---|---|
| |
| |
| 5,000 (3,500 when fronting on and having a main/front entrance facing the Linear Park or Amenity Space) |
| 40 |
| 50 |
| |
| |
| 30 |
| 20 |
| 40 |
| |
| |
| 20 (15 to porches) |
| 15 (10 to porches) |
| 10 (5 to porches) |
| 5 |
| 15 |
| |
| 10[5] (rear-loaded) |
| |
| 1 one side[6], 3 one side |
| 5 on each side |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.5
| |
| Table 19.2-24.5 Required Conditions for Commercial/High- Density Residential/Mixed-Use District | |
|---|---|
| |
| |
| 5,000 (3,500 when fronting on and having a main/front entrance facing the Linear Park or Amenity Space) |
| 40 |
| 50 |
| |
| |
| 30 |
| 20 |
| 40 |
| |
| |
| 20 (15 to porches) |
| 15 (10 to porches) |
| 10 (5 to porches) |
| 5 |
| 15 |
| |
| 10[5] (rear-loaded) |
| |
| 1 one side[6], 3 one side |
| 5 on each side |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.5
| |
| Table 19.2-24.5 Required Conditions for Commercial/High- Density Residential/Mixed-Use District | |
|---|---|
| |
| |
| 5,000 (3,500 when fronting on and having a main/front entrance facing the Linear Park or Amenity Space) |
| 40 |
| 50 |
| |
| |
| 30 |
| 20 |
| 40 |
| |
| |
| 20 (15 to porches) |
| 15 (10 to porches) |
| 10 (5 to porches) |
| 5 |
| 15 |
| |
| 10[5] (rear-loaded) |
| |
| 1 one side[6], 3 one side |
| 5 on each side |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.5
| |
| Table 19.2-24.5 Required Conditions for Commercial/High- Density Residential/Mixed-Use District | |
|---|---|
| |
| |
| 5,000 (3,500 when fronting on and having a main/front entrance facing the Linear Park or Amenity Space) |
| 40 |
| 50 |
| |
| |
| 30 |
| 20 |
| 40 |
| |
| |
| 20 (15 to porches) |
| 15 (10 to porches) |
| 10 (5 to porches) |
| 5 |
| 15 |
| |
| 10[5] (rear-loaded) |
| |
| 1 one side[6], 3 one side |
| 5 on each side |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.5
| |
| Table 19.2-24.6 Required Conditions for Medium- Density Residential with Nodal Mixed-Use District | |
|---|---|
| |
| 5 ac |
| No max. |
| |
| 50 where not rear-loaded |
| 15 where not rear-loaded |
| See Section 19.2-24.J. |
| 10 |
| |
| 1,500 |
| 16 |
| 50, 70 (where rear-loaded) |
| |
| |
| 50 |
| 15 (10 to porches) |
| 15 (10 to porches) |
| 8 |
| 15[6] |
| |
| 10 |
| 20 |
| |
| 3 stories |
| 4 stories |
| |
| None required |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.6
| |
| Table 19.2-24.6 Required Conditions for Medium- Density Residential with Nodal Mixed-Use District | |
|---|---|
| |
| 5 ac |
| No max. |
| |
| 50 where not rear-loaded |
| 15 where not rear-loaded |
| See Section 19.2-24.J. |
| 10 |
| |
| 1,500 |
| 16 |
| 50, 70 (where rear-loaded) |
| |
| |
| 50 |
| 15 (10 to porches) |
| 15 (10 to porches) |
| 8 |
| 15[6] |
| |
| 10 |
| 20 |
| |
| 3 stories |
| 4 stories |
| |
| None required |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.6
| |
| Table 19.2-24.6 Required Conditions for Medium- Density Residential with Nodal Mixed-Use District | |
|---|---|
| |
| 5 ac |
| No max. |
| |
| 50 where not rear-loaded |
| 15 where not rear-loaded |
| See Section 19.2-24.J. |
| 10 |
| |
| 1,500 |
| 16 |
| 50, 70 (where rear-loaded) |
| |
| |
| 50 |
| 15 (10 to porches) |
| 15 (10 to porches) |
| 8 |
| 15[6] |
| |
| 10 |
| 20 |
| |
| 3 stories |
| 4 stories |
| |
| None required |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.6
| |
| Table 19.2-24.6 Required Conditions for Medium- Density Residential with Nodal Mixed-Use District | |
|---|---|
| |
| 5 ac |
| No max. |
| |
| 50 where not rear-loaded |
| 15 where not rear-loaded |
| See Section 19.2-24.J. |
| 10 |
| |
| 1,500 |
| 16 |
| 50, 70 (where rear-loaded) |
| |
| |
| 50 |
| 15 (10 to porches) |
| 15 (10 to porches) |
| 8 |
| 15[6] |
| |
| 10 |
| 20 |
| |
| 3 stories |
| 4 stories |
| |
| None required |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.6
| |
| Table 19.2-24.7 Required Conditions for Commercial/High-Density Residential/Mixed-Use District | |
|---|---|
| |
| No min. |
| No max. |
| See Section19.2-24.J. |
| 15 |
| |
| 1,400 |
| 16 |
| 75 |
| |
| |
| 50 |
| 15 (10 to porches) |
| |
| 15 (10 to porches) |
| 10 (5 to porches) |
| 5 |
| |
| 15 (10 to porches) |
| 10 (5 to porches) |
| |
| 10 |
| 20 |
| 4 stories |
| |
| None required |
| 10 for local streets, 15 for collectors |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.7
| |
| Table 19.2-24.7 Required Conditions for Commercial/High-Density Residential/Mixed-Use District | |
|---|---|
| |
| No min. |
| No max. |
| See Section19.2-24.J. |
| 15 |
| |
| 1,400 |
| 16 |
| 75 |
| |
| |
| 50 |
| 15 (10 to porches) |
| |
| 15 (10 to porches) |
| 10 (5 to porches) |
| 5 |
| |
| 15 (10 to porches) |
| 10 (5 to porches) |
| |
| 10 |
| 20 |
| 4 stories |
| |
| None required |
| 10 for local streets, 15 for collectors |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.7
| |
| Table 19.2-24.7 Required Conditions for Commercial/High-Density Residential/Mixed-Use District | |
|---|---|
| |
| No min. |
| No max. |
| See Section19.2-24.J. |
| 15 |
| |
| 1,400 |
| 16 |
| 75 |
| |
| |
| 50 |
| 15 (10 to porches) |
| |
| 15 (10 to porches) |
| 10 (5 to porches) |
| 5 |
| |
| 15 (10 to porches) |
| 10 (5 to porches) |
| |
| 10 |
| 20 |
| 4 stories |
| |
| None required |
| 10 for local streets, 15 for collectors |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.7
| |
| Table 19.2-24.7 Required Conditions for Commercial/High-Density Residential/Mixed-Use District | |
|---|---|
| |
| No min. |
| No max. |
| See Section19.2-24.J. |
| 15 |
| |
| 1,400 |
| 16 |
| 75 |
| |
| |
| 50 |
| 15 (10 to porches) |
| |
| 15 (10 to porches) |
| 10 (5 to porches) |
| 5 |
| |
| 15 (10 to porches) |
| 10 (5 to porches) |
| |
| 10 |
| 20 |
| 4 stories |
| |
| None required |
| 10 for local streets, 15 for collectors |
| 10 |
| 2 stories or 30 feet |
Notes for Table 19.2-24.7
| |
| Table 19.2-24.8 Required Conditions for Medium-Density Residential with Nodal Mixed-Use District | |
|---|---|
| Project Standards | |
| 5 acres, no min. when non-residential uses are included within a building |
| |
| 1 |
| 2 |
| [2] |
| 30 |
| 24 |
| 50[3] |
Notes for Table 19.2-24.8
| |
| Table 19.2-24.8 Required Conditions for Medium-Density Residential with Nodal Mixed-Use District | |
|---|---|
| Project Standards | |
| 5 acres, no min. when non-residential uses are included within a building |
| |
| 1 |
| 2 |
| [2] |
| 30 |
| 24 |
| 50[3] |
Notes for Table 19.2-24.8
| |
| Table 19.2-24.8 Required Conditions for Medium-Density Residential with Nodal Mixed-Use District | |
|---|---|
| Project Standards | |
| 5 acres, no min. when non-residential uses are included within a building |
| |
| 1 |
| 2 |
| [2] |
| 30 |
| 24 |
| 50[3] |
Notes for Table 19.2-24.8
| |
| Table 19.2-24.8 Required Conditions for Medium-Density Residential with Nodal Mixed-Use District | |
|---|---|
| Project Standards | |
| 5 acres, no min. when non-residential uses are included within a building |
| |
| 1 |
| 2 |
| [2] |
| 30 |
| 24 |
| 50[3] |
Notes for Table 19.2-24.8
| |
| Table 19.2-24.9 Required Conditions for Medium-Density Residential with Nodal Mixed-Use District | |
|---|---|
| Building Standards | |
| |
| |
| 10, No Perimeter Landscaping required |
| No setback or Perimeter Landscaping required |
| |
| 15/A[4] |
| 40/C |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| None required |
| None required |
| None required |
| No maximum |
| |
| 3 stories |
| 8 stories |
| |
| Same as principal buildings |
Notes for Table 19.2-24.9
| |
| Table 19.2-24.9 Required Conditions for Medium-Density Residential with Nodal Mixed-Use District | |
|---|---|
| Building Standards | |
| |
| |
| 10, No Perimeter Landscaping required |
| No setback or Perimeter Landscaping required |
| |
| 15/A[4] |
| 40/C |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| None required |
| None required |
| None required |
| No maximum |
| |
| 3 stories |
| 8 stories |
| |
| Same as principal buildings |
Notes for Table 19.2-24.9
| |
| Table 19.2-24.9 Required Conditions for Medium-Density Residential with Nodal Mixed-Use District | |
|---|---|
| Building Standards | |
| |
| |
| 10, No Perimeter Landscaping required |
| No setback or Perimeter Landscaping required |
| |
| 15/A[4] |
| 40/C |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| None required |
| None required |
| None required |
| No maximum |
| |
| 3 stories |
| 8 stories |
| |
| Same as principal buildings |
Notes for Table 19.2-24.9
| |
| Table 19.2-24.9 Required Conditions for Medium-Density Residential with Nodal Mixed-Use District | |
|---|---|
| Building Standards | |
| |
| |
| 10, No Perimeter Landscaping required |
| No setback or Perimeter Landscaping required |
| |
| 15/A[4] |
| 40/C |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| None required |
| None required |
| None required |
| No maximum |
| |
| 3 stories |
| 8 stories |
| |
| Same as principal buildings |
Notes for Table 19.2-24.9
| |
| Table 19.2-24.10 Required Conditions for Commercial/High-Density Residential/Mixed-Use District | |
|---|---|
| Project Standards | |
| None required |
| |
| 1 |
| 2 |
| [2] |
| 30 |
| 24 |
Notes for Table 19.2-24.10
| |
| Table 19.2-24.10 Required Conditions for Commercial/High-Density Residential/Mixed-Use District | |
|---|---|
| Project Standards | |
| None required |
| |
| 1 |
| 2 |
| [2] |
| 30 |
| 24 |
Notes for Table 19.2-24.10
| |
| Table 19.2-24.10 Required Conditions for Commercial/High-Density Residential/Mixed-Use District | |
|---|---|
| Project Standards | |
| None required |
| |
| 1 |
| 2 |
| [2] |
| 30 |
| 24 |
Notes for Table 19.2-24.10
| |
| Table 19.2-24.10 Required Conditions for Commercial/High-Density Residential/Mixed-Use District | |
|---|---|
| Project Standards | |
| None required |
| |
| 1 |
| 2 |
| [2] |
| 30 |
| 24 |
Notes for Table 19.2-24.10
| |
| Table 19.2-24.11 Required Conditions for Commercial/High-Density Residential/Mixed-Use District | |
|---|---|
| Building Standards | |
| |
| |
| 10, No Perimeter Landscaping required |
| No setback or Perimeter Landscaping required |
| |
| 15/A[4] |
| 40/C |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| None required |
| None required |
| None required |
| No maximum |
| |
| 3 stories |
| 8 stories |
| |
| Same as principal buildings |
Table 19.2-24.11
| |
| Table 19.2-24.11 Required Conditions for Commercial/High-Density Residential/Mixed-Use District | |
|---|---|
| Building Standards | |
| |
| |
| 10, No Perimeter Landscaping required |
| No setback or Perimeter Landscaping required |
| |
| 15/A[4] |
| 40/C |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| None required |
| None required |
| None required |
| No maximum |
| |
| 3 stories |
| 8 stories |
| |
| Same as principal buildings |
Table 19.2-24.11
| |
| Table 19.2-24.11 Required Conditions for Commercial/High-Density Residential/Mixed-Use District | |
|---|---|
| Building Standards | |
| |
| |
| 10, No Perimeter Landscaping required |
| No setback or Perimeter Landscaping required |
| |
| 15/A[4] |
| 40/C |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| None required |
| None required |
| None required |
| No maximum |
| |
| 3 stories |
| 8 stories |
| |
| Same as principal buildings |
Table 19.2-24.11
| |
| Table 19.2-24.11 Required Conditions for Commercial/High-Density Residential/Mixed-Use District | |
|---|---|
| Building Standards | |
| |
| |
| 10, No Perimeter Landscaping required |
| No setback or Perimeter Landscaping required |
| |
| 15/A[4] |
| 40/C |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| 10/A[4] |
| No Setback or Perimeter Landscaping required |
| None required |
| None required |
| None required |
| No maximum |
| |
| 3 stories |
| 8 stories |
| |
| Same as principal buildings |
Table 19.2-24.11
| |
Purpose: pursuant to the Comprehensive Plan, this section:
| Table 19.2-25.1 Airport Overlay Zones | |
|---|---|
| Zone | Description |
| Airport zone | Horizontal zone centered about and above the runway, with the floor of the zone 387 feet above mean sea level. |
| Approach zone | Sloping zone that extends away from the runway ends along the extended runway centerline, with the floor set by the approach surfaces. The lower surface of the approach zone equals the runway end elevation. The surface of the zone slopes upward as it extends away from the runway. |
| Transitional zone | Sloping zone that fans away perpendicular to the runway centerline and approach surfaces, with the floor set by the transitional surfaces. |
| Conical zone | Sloping zone that circles around the periphery of, and outward from, the airport zone with the floor set by the conical surface. The lower surface of the conical zone touches the airport zone at an elevation of 387 feet above mean sea level and slopes upward and outward to an elevation of 587 feet above mean sea level. |
| Primary zone | Generally horizontal zone that is centered about the runway. The surface of the zone is the same elevation as the elevation of the nearest point of the runway centerline. |
| Table 19.2-25.1 Airport Overlay Zones | |
|---|---|
| Zone | Description |
| Airport zone | Horizontal zone centered about and above the runway, with the floor of the zone 387 feet above mean sea level. |
| Approach zone | Sloping zone that extends away from the runway ends along the extended runway centerline, with the floor set by the approach surfaces. The lower surface of the approach zone equals the runway end elevation. The surface of the zone slopes upward as it extends away from the runway. |
| Transitional zone | Sloping zone that fans away perpendicular to the runway centerline and approach surfaces, with the floor set by the transitional surfaces. |
| Conical zone | Sloping zone that circles around the periphery of, and outward from, the airport zone with the floor set by the conical surface. The lower surface of the conical zone touches the airport zone at an elevation of 387 feet above mean sea level and slopes upward and outward to an elevation of 587 feet above mean sea level. |
| Primary zone | Generally horizontal zone that is centered about the runway. The surface of the zone is the same elevation as the elevation of the nearest point of the runway centerline. |
| Table 19.2-25.1 Airport Overlay Zones | |
|---|---|
| Zone | Description |
| Airport zone | Horizontal zone centered about and above the runway, with the floor of the zone 387 feet above mean sea level. |
| Approach zone | Sloping zone that extends away from the runway ends along the extended runway centerline, with the floor set by the approach surfaces. The lower surface of the approach zone equals the runway end elevation. The surface of the zone slopes upward as it extends away from the runway. |
| Transitional zone | Sloping zone that fans away perpendicular to the runway centerline and approach surfaces, with the floor set by the transitional surfaces. |
| Conical zone | Sloping zone that circles around the periphery of, and outward from, the airport zone with the floor set by the conical surface. The lower surface of the conical zone touches the airport zone at an elevation of 387 feet above mean sea level and slopes upward and outward to an elevation of 587 feet above mean sea level. |
| Primary zone | Generally horizontal zone that is centered about the runway. The surface of the zone is the same elevation as the elevation of the nearest point of the runway centerline. |
| Table 19.2-25.1 Airport Overlay Zones | |
|---|---|
| Zone | Description |
| Airport zone | Horizontal zone centered about and above the runway, with the floor of the zone 387 feet above mean sea level. |
| Approach zone | Sloping zone that extends away from the runway ends along the extended runway centerline, with the floor set by the approach surfaces. The lower surface of the approach zone equals the runway end elevation. The surface of the zone slopes upward as it extends away from the runway. |
| Transitional zone | Sloping zone that fans away perpendicular to the runway centerline and approach surfaces, with the floor set by the transitional surfaces. |
| Conical zone | Sloping zone that circles around the periphery of, and outward from, the airport zone with the floor set by the conical surface. The lower surface of the conical zone touches the airport zone at an elevation of 387 feet above mean sea level and slopes upward and outward to an elevation of 587 feet above mean sea level. |
| Primary zone | Generally horizontal zone that is centered about the runway. The surface of the zone is the same elevation as the elevation of the nearest point of the runway centerline. |
Purpose: This Section protects and improves water quality in the Chesapeake Bay and its tributaries by requiring the use of effective conservation planning and pollution prevention practices when using and developing environmentally sensitive lands. This Section implements the Chesapeake Bay Preservation Act (Act) (Code of Virginia Title 62.1, Chapter 3.1, Article 2.5, § 62.1-44.15:67 et seq.). The two types of Chesapeake Bay Preservation Areas (CBPA) are Resource Protection Areas (RPA) and Resource Management Areas (RMA). RPAs serve an important water quality function by protecting County water bodies and providing a buffer adjacent to them. The buffer acts to filter runoff prior to entering water bodies. RMAs also include land types that have the potential to cause significant water quality degradation or for diminishing the functional value of the RPA if they are improperly used or developed. The entire County is designated as an RMA.
Purpose: The floodplain management regulations set forth in this Section are adopted pursuant to the authority set forth in Va. Code § 15.2-2280 and may be referred to as the floodplain management ordinance. The purpose of these provisions is to prevent loss of life and property, creation of hazards to health and safety, disruption of commercial and governmental services, extraordinary and unnecessary expenditure of public funds for flood protection and relief and impairment of the tax base by:
Floodway District. The following shall be prohibited in the floodway district: structures, substantial improvements, manufactured homes, fill or other development. The County shall not grant relief from this provision through any process, unless relief from this provision shall have first been approved by FEMA to the extent that the Director of Environmental Engineering determines that FEMA approval is required.