DOWNTOWN DT
| Related Provisions | ||
|---|---|---|
| Sec. 10-1-1.3 | Land Use Matrix | Permitted, specially permitted, conditional, and accessory uses permitted within the NC and CM districts |
| Sec. 10-1-1.4 | Land Use Standards | Standards that apply to land uses denoted with an "S" in Section 10-1-1.3, Land Use Matrix |
| Sec. 10-9-5.1 | Conditional Use Standards | Standards for land uses denoted as "C" in Section 10-1-1.3, Land Use Matrix |
| Sec. 10-1-2.3 | Height and Yard Exceptions | Allowable exceptions to the setbacks and heights within the NC and CM districts |
| Sec. 10-1-3.1 | General Design Standards | Standards relating to wall articulation, varied massing, blank walls, and screening |
| Sec. 10-1-3.2 | Non-Residential and Mixed-Use Design Standards | Permitted and alternative materials and CPTED review standards |
| Sec. 10-9-5.8 | Adaptive Reuse Plan | Development standards and reuse incentives for the revitalization or redevelopment of buildings |
| Sec. 10-1-3.4 | Sustainable Building Design | Incentives for the use of sustainable design and development practices |
| Sec. 10-1-3.7 | Vehicle Mobility | Minimum required and maximum allowable parking, credits and reductions, vehicle access and parking design, landscape and screening standards, and pedestrian circulation (Subsection 10-1-3.7.B, Parking and Access in the DT Districts) |
| Sec. 10-1-3.8 | Alternative Mobility | Bicycle parking standards |
| Sec. 10-1-3.11 | Outdoor Lighting Standards | Standards for on-site exterior lighting and for certain districts, uses and site features |
| Sec. 10-9-3.10 | Development Review Summary | Descriptions of all required approval and permit processes |
| Sec. 10-12-2.1 | Definitions | Definitions of land uses and general terms |
| Base Standards | ||
| Sec. 10-1-3.6 | Greenspace Design Standards | General planting, landscape, bufferyard and tree canopy coverage requirements |
| Sec. 10-1-3.10 | Sign Standards | Signs allowed and prohibited, installation and maintenance requirements, means of measuring sign dimensions, bonuses, and standards for temporary signs |
| Related Provisions | ||
|---|---|---|
| Sec. 10-1-1.3 | Land Use Matrix | Permitted, specially permitted, conditional, and accessory uses permitted within the NC and CM districts |
| Sec. 10-1-1.4 | Land Use Standards | Standards that apply to land uses denoted with an "S" in Section 10-1-1.3, Land Use Matrix |
| Sec. 10-9-5.1 | Conditional Use Standards | Standards for land uses denoted as "C" in Section 10-1-1.3, Land Use Matrix |
| Sec. 10-1-2.3 | Height and Yard Exceptions | Allowable exceptions to the setbacks and heights within the NC and CM districts |
| Sec. 10-1-3.1 | General Design Standards | Standards relating to wall articulation, varied massing, blank walls, and screening |
| Sec. 10-1-3.2 | Non-Residential and Mixed-Use Design Standards | Permitted and alternative materials and CPTED review standards |
| Sec. 10-9-5.8 | Adaptive Reuse Plan | Development standards and reuse incentives for the revitalization or redevelopment of buildings |
| Sec. 10-1-3.4 | Sustainable Building Design | Incentives for the use of sustainable design and development practices |
| Sec. 10-1-3.7 | Vehicle Mobility | Minimum required and maximum allowable parking, credits and reductions, vehicle access and parking design, landscape and screening standards, and pedestrian circulation (Subsection 10-1-3.7.B, Parking and Access in the DT Districts) |
| Sec. 10-1-3.8 | Alternative Mobility | Bicycle parking standards |
| Sec. 10-1-3.11 | Outdoor Lighting Standards | Standards for on-site exterior lighting and for certain districts, uses and site features |
| Sec. 10-9-3.10 | Development Review Summary | Descriptions of all required approval and permit processes |
| Sec. 10-12-2.1 | Definitions | Definitions of land uses and general terms |
| Base Standards | ||
| Sec. 10-1-3.6 | Greenspace Design Standards | General planting, landscape, bufferyard and tree canopy coverage requirements |
| Sec. 10-1-3.10 | Sign Standards | Signs allowed and prohibited, installation and maintenance requirements, means of measuring sign dimensions, bonuses, and standards for temporary signs |
| Related Provisions | ||
|---|---|---|
| Sec. 10-1-1.3 | Land Use Matrix | Permitted, specially permitted, conditional, and accessory uses permitted within the NC and CM districts |
| Sec. 10-1-1.4 | Land Use Standards | Standards that apply to land uses denoted with an "S" in Section 10-1-1.3, Land Use Matrix |
| Sec. 10-9-5.1 | Conditional Use Standards | Standards for land uses denoted as "C" in Section 10-1-1.3, Land Use Matrix |
| Sec. 10-1-2.3 | Height and Yard Exceptions | Allowable exceptions to the setbacks and heights within the NC and CM districts |
| Sec. 10-1-3.1 | General Design Standards | Standards relating to wall articulation, varied massing, blank walls, and screening |
| Sec. 10-1-3.2 | Non-Residential and Mixed-Use Design Standards | Permitted and alternative materials and CPTED review standards |
| Sec. 10-9-5.8 | Adaptive Reuse Plan | Development standards and reuse incentives for the revitalization or redevelopment of buildings |
| Sec. 10-1-3.4 | Sustainable Building Design | Incentives for the use of sustainable design and development practices |
| Sec. 10-1-3.7 | Vehicle Mobility | Minimum required and maximum allowable parking, credits and reductions, vehicle access and parking design, landscape and screening standards, and pedestrian circulation (Subsection 10-1-3.7.B, Parking and Access in the DT Districts) |
| Sec. 10-1-3.8 | Alternative Mobility | Bicycle parking standards |
| Sec. 10-1-3.11 | Outdoor Lighting Standards | Standards for on-site exterior lighting and for certain districts, uses and site features |
| Sec. 10-9-3.10 | Development Review Summary | Descriptions of all required approval and permit processes |
| Sec. 10-12-2.1 | Definitions | Definitions of land uses and general terms |
| Base Standards | ||
| Sec. 10-1-3.6 | Greenspace Design Standards | General planting, landscape, bufferyard and tree canopy coverage requirements |
| Sec. 10-1-3.10 | Sign Standards | Signs allowed and prohibited, installation and maintenance requirements, means of measuring sign dimensions, bonuses, and standards for temporary signs |
| Related Provisions | ||
|---|---|---|
| Sec. 10-1-1.3 | Land Use Matrix | Permitted, specially permitted, conditional, and accessory uses permitted within the NC and CM districts |
| Sec. 10-1-1.4 | Land Use Standards | Standards that apply to land uses denoted with an "S" in Section 10-1-1.3, Land Use Matrix |
| Sec. 10-9-5.1 | Conditional Use Standards | Standards for land uses denoted as "C" in Section 10-1-1.3, Land Use Matrix |
| Sec. 10-1-2.3 | Height and Yard Exceptions | Allowable exceptions to the setbacks and heights within the NC and CM districts |
| Sec. 10-1-3.1 | General Design Standards | Standards relating to wall articulation, varied massing, blank walls, and screening |
| Sec. 10-1-3.2 | Non-Residential and Mixed-Use Design Standards | Permitted and alternative materials and CPTED review standards |
| Sec. 10-9-5.8 | Adaptive Reuse Plan | Development standards and reuse incentives for the revitalization or redevelopment of buildings |
| Sec. 10-1-3.4 | Sustainable Building Design | Incentives for the use of sustainable design and development practices |
| Sec. 10-1-3.7 | Vehicle Mobility | Minimum required and maximum allowable parking, credits and reductions, vehicle access and parking design, landscape and screening standards, and pedestrian circulation (Subsection 10-1-3.7.B, Parking and Access in the DT Districts) |
| Sec. 10-1-3.8 | Alternative Mobility | Bicycle parking standards |
| Sec. 10-1-3.11 | Outdoor Lighting Standards | Standards for on-site exterior lighting and for certain districts, uses and site features |
| Sec. 10-9-3.10 | Development Review Summary | Descriptions of all required approval and permit processes |
| Sec. 10-12-2.1 | Definitions | Definitions of land uses and general terms |
| Base Standards | ||
| Sec. 10-1-3.6 | Greenspace Design Standards | General planting, landscape, bufferyard and tree canopy coverage requirements |
| Sec. 10-1-3.10 | Sign Standards | Signs allowed and prohibited, installation and maintenance requirements, means of measuring sign dimensions, bonuses, and standards for temporary signs |
(Ord. 20, Series of 2023)
(Ord. 18, Series of 2022)
Effective on: 8/25/2022
Effective on: 10/28/2021
(Ord. 18, Series of 2022)
Effective on: 8/25/2022
Effective on: 10/28/2021
Table 10-2-3.1 Building Materials Permitted by DT District | |||||
|---|---|---|---|---|---|
| P = Primary material; S = Secondary material (less than 25% of façade area); "--" = Not permitted | |||||
| Material Type | DNR | DMU | DMS | DTA | |
| 1 Masonry | |||||
| 1a) | Modular Brick | P, S | P, S | P, S | P, S |
| 1b) | Modular Stone | P, S | P, S | S | P, S |
| 1c) | Architectural cast or precast concrete (detailed) | S | P, S | S | P, S |
| 1d) | Architectural reinforced concrete (glass fiber, fiber) | -- | P, S | -- | S |
| 1e) | Cement board siding | P, S | P, S | -- | S |
| 1f) | Terra cotta | P, S | P, S | P, S | P, S |
| 1g) | Cast stone | P, S | P, S | S | P, S |
| 1h) | An architectural concrete masonry unit | -- | S | -- | S |
| 1i) | Panelized brick or stone | S | P, S | -- | S |
| 2 Metal | |||||
| 2a) | Metal panels | -- | S | S | S |
| 2b) | Metal accents | S | S | S | S |
| 3 Siding | |||||
| 3a) | Horizontal lap (wood, cement board) | P, S | S | S* | P, S |
| 3b) | Shingles (wood, cement board) | P, S | S | -- | P, S |
| Vertical board and batten (wood, cement board) | P, S | -- | -- | P, S | |
| 4 Stucco | |||||
| 4a) | Authentic | P, S | P, S | P, S | P, S |
| 4b) | Synthetic (scored) | S | P, S | -- | S |
| 4c) | Synthetic (not scored) | S | -- | -- | S |
| 5 Glass | |||||
| 5a) | Curtain wall | -- | S | -- | S |
| 5b) | Glass Accent | S | S | S | S |
| TABLE NOTES: *This is only allowed on upper stories that are stepped back from the building front. | |||||
Table 10-2-3.1 Building Materials Permitted by DT District | |||||
|---|---|---|---|---|---|
| P = Primary material; S = Secondary material (less than 25% of façade area); "--" = Not permitted | |||||
| Material Type | DNR | DMU | DMS | DTA | |
| 1 Masonry | |||||
| 1a) | Modular Brick | P, S | P, S | P, S | P, S |
| 1b) | Modular Stone | P, S | P, S | S | P, S |
| 1c) | Architectural cast or precast concrete (detailed) | S | P, S | S | P, S |
| 1d) | Architectural reinforced concrete (glass fiber, fiber) | -- | P, S | -- | S |
| 1e) | Cement board siding | P, S | P, S | -- | S |
| 1f) | Terra cotta | P, S | P, S | P, S | P, S |
| 1g) | Cast stone | P, S | P, S | S | P, S |
| 1h) | An architectural concrete masonry unit | -- | S | -- | S |
| 1i) | Panelized brick or stone | S | P, S | -- | S |
| 2 Metal | |||||
| 2a) | Metal panels | -- | S | S | S |
| 2b) | Metal accents | S | S | S | S |
| 3 Siding | |||||
| 3a) | Horizontal lap (wood, cement board) | P, S | S | S* | P, S |
| 3b) | Shingles (wood, cement board) | P, S | S | -- | P, S |
| Vertical board and batten (wood, cement board) | P, S | -- | -- | P, S | |
| 4 Stucco | |||||
| 4a) | Authentic | P, S | P, S | P, S | P, S |
| 4b) | Synthetic (scored) | S | P, S | -- | S |
| 4c) | Synthetic (not scored) | S | -- | -- | S |
| 5 Glass | |||||
| 5a) | Curtain wall | -- | S | -- | S |
| 5b) | Glass Accent | S | S | S | S |
| TABLE NOTES: *This is only allowed on upper stories that are stepped back from the building front. | |||||
Table 10-2-3.1 Building Materials Permitted by DT District | |||||
|---|---|---|---|---|---|
| P = Primary material; S = Secondary material (less than 25% of façade area); "--" = Not permitted | |||||
| Material Type | DNR | DMU | DMS | DTA | |
| 1 Masonry | |||||
| 1a) | Modular Brick | P, S | P, S | P, S | P, S |
| 1b) | Modular Stone | P, S | P, S | S | P, S |
| 1c) | Architectural cast or precast concrete (detailed) | S | P, S | S | P, S |
| 1d) | Architectural reinforced concrete (glass fiber, fiber) | -- | P, S | -- | S |
| 1e) | Cement board siding | P, S | P, S | -- | S |
| 1f) | Terra cotta | P, S | P, S | P, S | P, S |
| 1g) | Cast stone | P, S | P, S | S | P, S |
| 1h) | An architectural concrete masonry unit | -- | S | -- | S |
| 1i) | Panelized brick or stone | S | P, S | -- | S |
| 2 Metal | |||||
| 2a) | Metal panels | -- | S | S | S |
| 2b) | Metal accents | S | S | S | S |
| 3 Siding | |||||
| 3a) | Horizontal lap (wood, cement board) | P, S | S | S* | P, S |
| 3b) | Shingles (wood, cement board) | P, S | S | -- | P, S |
| Vertical board and batten (wood, cement board) | P, S | -- | -- | P, S | |
| 4 Stucco | |||||
| 4a) | Authentic | P, S | P, S | P, S | P, S |
| 4b) | Synthetic (scored) | S | P, S | -- | S |
| 4c) | Synthetic (not scored) | S | -- | -- | S |
| 5 Glass | |||||
| 5a) | Curtain wall | -- | S | -- | S |
| 5b) | Glass Accent | S | S | S | S |
| TABLE NOTES: *This is only allowed on upper stories that are stepped back from the building front. | |||||
Table 10-2-3.1 Building Materials Permitted by DT District | |||||
|---|---|---|---|---|---|
| P = Primary material; S = Secondary material (less than 25% of façade area); "--" = Not permitted | |||||
| Material Type | DNR | DMU | DMS | DTA | |
| 1 Masonry | |||||
| 1a) | Modular Brick | P, S | P, S | P, S | P, S |
| 1b) | Modular Stone | P, S | P, S | S | P, S |
| 1c) | Architectural cast or precast concrete (detailed) | S | P, S | S | P, S |
| 1d) | Architectural reinforced concrete (glass fiber, fiber) | -- | P, S | -- | S |
| 1e) | Cement board siding | P, S | P, S | -- | S |
| 1f) | Terra cotta | P, S | P, S | P, S | P, S |
| 1g) | Cast stone | P, S | P, S | S | P, S |
| 1h) | An architectural concrete masonry unit | -- | S | -- | S |
| 1i) | Panelized brick or stone | S | P, S | -- | S |
| 2 Metal | |||||
| 2a) | Metal panels | -- | S | S | S |
| 2b) | Metal accents | S | S | S | S |
| 3 Siding | |||||
| 3a) | Horizontal lap (wood, cement board) | P, S | S | S* | P, S |
| 3b) | Shingles (wood, cement board) | P, S | S | -- | P, S |
| Vertical board and batten (wood, cement board) | P, S | -- | -- | P, S | |
| 4 Stucco | |||||
| 4a) | Authentic | P, S | P, S | P, S | P, S |
| 4b) | Synthetic (scored) | S | P, S | -- | S |
| 4c) | Synthetic (not scored) | S | -- | -- | S |
| 5 Glass | |||||
| 5a) | Curtain wall | -- | S | -- | S |
| 5b) | Glass Accent | S | S | S | S |
| TABLE NOTES: *This is only allowed on upper stories that are stepped back from the building front. | |||||
Effective on: 10/28/2021
Table 10-2-3.2.1 Permitted Building Types by District | ||||
|---|---|---|---|---|
| Building Type | Downtown Zoning Districts | |||
| Downtown Neighborhood Residential (DNR) | Downtown Transition Area (DTA) | Downtown Main Street (DMS) | Downtown Mixed-Use (DMU) | |
| Residential | ||||
| Apartment | -- | P | -- | P |
| Mixed-Use Building (upper floor residential units) | -- | P | P | P |
| Dwelling, Single-Family Attached / Duplex | P | P | -- | P |
| Dwelling, Single-Family Detached | P | P | -- | P |
| Multiplex (3-6 residential units) | P | P | -- | P |
| Townhouse | P | P | -- | P |
| Non-residential / Mixed-Use | ||||
| Live-Work | -- | P | -- | P |
| Mixed-Use | -- | P | P | P |
| Commercial | -- | P | P | P |
| Office-Institutional | -- | P | P | P |
| Parking Structure | -- | P | P | P |
Table 10-2-3.2.1 Permitted Building Types by District | ||||
|---|---|---|---|---|
| Building Type | Downtown Zoning Districts | |||
| Downtown Neighborhood Residential (DNR) | Downtown Transition Area (DTA) | Downtown Main Street (DMS) | Downtown Mixed-Use (DMU) | |
| Residential | ||||
| Apartment | -- | P | -- | P |
| Mixed-Use Building (upper floor residential units) | -- | P | P | P |
| Dwelling, Single-Family Attached / Duplex | P | P | -- | P |
| Dwelling, Single-Family Detached | P | P | -- | P |
| Multiplex (3-6 residential units) | P | P | -- | P |
| Townhouse | P | P | -- | P |
| Non-residential / Mixed-Use | ||||
| Live-Work | -- | P | -- | P |
| Mixed-Use | -- | P | P | P |
| Commercial | -- | P | P | P |
| Office-Institutional | -- | P | P | P |
| Parking Structure | -- | P | P | P |
Table 10-2-3.2.1 Permitted Building Types by District | ||||
|---|---|---|---|---|
| Building Type | Downtown Zoning Districts | |||
| Downtown Neighborhood Residential (DNR) | Downtown Transition Area (DTA) | Downtown Main Street (DMS) | Downtown Mixed-Use (DMU) | |
| Residential | ||||
| Apartment | -- | P | -- | P |
| Mixed-Use Building (upper floor residential units) | -- | P | P | P |
| Dwelling, Single-Family Attached / Duplex | P | P | -- | P |
| Dwelling, Single-Family Detached | P | P | -- | P |
| Multiplex (3-6 residential units) | P | P | -- | P |
| Townhouse | P | P | -- | P |
| Non-residential / Mixed-Use | ||||
| Live-Work | -- | P | -- | P |
| Mixed-Use | -- | P | P | P |
| Commercial | -- | P | P | P |
| Office-Institutional | -- | P | P | P |
| Parking Structure | -- | P | P | P |
Table 10-2-3.2.1 Permitted Building Types by District | ||||
|---|---|---|---|---|
| Building Type | Downtown Zoning Districts | |||
| Downtown Neighborhood Residential (DNR) | Downtown Transition Area (DTA) | Downtown Main Street (DMS) | Downtown Mixed-Use (DMU) | |
| Residential | ||||
| Apartment | -- | P | -- | P |
| Mixed-Use Building (upper floor residential units) | -- | P | P | P |
| Dwelling, Single-Family Attached / Duplex | P | P | -- | P |
| Dwelling, Single-Family Detached | P | P | -- | P |
| Multiplex (3-6 residential units) | P | P | -- | P |
| Townhouse | P | P | -- | P |
| Non-residential / Mixed-Use | ||||
| Live-Work | -- | P | -- | P |
| Mixed-Use | -- | P | P | P |
| Commercial | -- | P | P | P |
| Office-Institutional | -- | P | P | P |
| Parking Structure | -- | P | P | P |
Table 10-2-4.1.1 Public Open Space Standards | |
|---|---|
| Type | Standard |
Plaza![]() | General Character
Location and Size
|
Pocket Park![]() | General Character
Location and Size
|
Common Green![]() | General Character
Location and Size
|
Paseo![]() | General Character
Location and Size
|
Rooftop Garden![]() | General Character
Location and Size
|
Parklet![]() | General Character
Location and Size
|
Table 10-2-4.1.1 Public Open Space Standards | |
|---|---|
| Type | Standard |
Plaza![]() | General Character
Location and Size
|
Pocket Park![]() | General Character
Location and Size
|
Common Green![]() | General Character
Location and Size
|
Paseo![]() | General Character
Location and Size
|
Rooftop Garden![]() | General Character
Location and Size
|
Parklet![]() | General Character
Location and Size
|
Table 10-2-4.1.1 Public Open Space Standards | |
|---|---|
| Type | Standard |
Plaza![]() | General Character
Location and Size
|
Pocket Park![]() | General Character
Location and Size
|
Common Green![]() | General Character
Location and Size
|
Paseo![]() | General Character
Location and Size
|
Rooftop Garden![]() | General Character
Location and Size
|
Parklet![]() | General Character
Location and Size
|
Table 10-2-4.1.1 Public Open Space Standards | |
|---|---|
| Type | Standard |
Plaza![]() | General Character
Location and Size
|
Pocket Park![]() | General Character
Location and Size
|
Common Green![]() | General Character
Location and Size
|
Paseo![]() | General Character
Location and Size
|
Rooftop Garden![]() | General Character
Location and Size
|
Parklet![]() | General Character
Location and Size
|
Table 10-2-4.1.2 Minimum Size of Trees or Shrubs at Installation | ||
|---|---|---|
Type of Plant | Distance from Public Right-of-Way | |
| 10 feet or less, or in tree lawns or medians | More than 10 feet | |
| Shade Tree (>30’ in mature height) | 2-inch caliper | 2-inch caliper |
| Ornamental Tree (<25’ in mature height) | 1.5-inch caliper | 1.5-inch caliper |
| Evergreen Tree | 8-feet in height | 6-feet in height |
| Shrub | 5-gallon container | 5-gallon container |
Table 10-2-4.1.2 Minimum Size of Trees or Shrubs at Installation | ||
|---|---|---|
Type of Plant | Distance from Public Right-of-Way | |
| 10 feet or less, or in tree lawns or medians | More than 10 feet | |
| Shade Tree (>30’ in mature height) | 2-inch caliper | 2-inch caliper |
| Ornamental Tree (<25’ in mature height) | 1.5-inch caliper | 1.5-inch caliper |
| Evergreen Tree | 8-feet in height | 6-feet in height |
| Shrub | 5-gallon container | 5-gallon container |
Table 10-2-4.1.2 Minimum Size of Trees or Shrubs at Installation | ||
|---|---|---|
Type of Plant | Distance from Public Right-of-Way | |
| 10 feet or less, or in tree lawns or medians | More than 10 feet | |
| Shade Tree (>30’ in mature height) | 2-inch caliper | 2-inch caliper |
| Ornamental Tree (<25’ in mature height) | 1.5-inch caliper | 1.5-inch caliper |
| Evergreen Tree | 8-feet in height | 6-feet in height |
| Shrub | 5-gallon container | 5-gallon container |
Table 10-2-4.1.2 Minimum Size of Trees or Shrubs at Installation | ||
|---|---|---|
Type of Plant | Distance from Public Right-of-Way | |
| 10 feet or less, or in tree lawns or medians | More than 10 feet | |
| Shade Tree (>30’ in mature height) | 2-inch caliper | 2-inch caliper |
| Ornamental Tree (<25’ in mature height) | 1.5-inch caliper | 1.5-inch caliper |
| Evergreen Tree | 8-feet in height | 6-feet in height |
| Shrub | 5-gallon container | 5-gallon container |
Effective on: 10/28/2021
| Figure 10-2-4.2.1 Bufferyard Illustration |
|---|
![]() |
Figure 10-2-4.2.2 Average Bufferyard Width |
|---|
![]() |
Table 10-2-4.2.1 Building Type Bufferyard Requirements | ||||
|---|---|---|---|---|
| District | SFD, SFA | MP, TH | LW, MU, APT | COM, OFF, INS, PS |
| SFD, SFA | -- | -- | R | R |
| MP, TH, | -- | -- | -- | R |
| LW, MU, APT | R | -- | -- | -- |
| COM, OFF, INS, PS | R | R | -- | -- |
Table Notes: SFD = Single-family detached; SFA = Single-family attached/Duplex; MP = Multiplex; TH = Townhouse; APT = Apartment; LW = Live-Work; MU = Mixed-Use; COM = Commercial; OFF = Office; INS = Institutional; PS = Parking Structure R = Bufferyard required | ||||
Table 10-2-4.2.1 Building Type Bufferyard Requirements | ||||
|---|---|---|---|---|
| District | SFD, SFA | MP, TH | LW, MU, APT | COM, OFF, INS, PS |
| SFD, SFA | -- | -- | R | R |
| MP, TH, | -- | -- | -- | R |
| LW, MU, APT | R | -- | -- | -- |
| COM, OFF, INS, PS | R | R | -- | -- |
Table Notes: SFD = Single-family detached; SFA = Single-family attached/Duplex; MP = Multiplex; TH = Townhouse; APT = Apartment; LW = Live-Work; MU = Mixed-Use; COM = Commercial; OFF = Office; INS = Institutional; PS = Parking Structure R = Bufferyard required | ||||
Table 10-2-4.2.1 Building Type Bufferyard Requirements | ||||
|---|---|---|---|---|
| District | SFD, SFA | MP, TH | LW, MU, APT | COM, OFF, INS, PS |
| SFD, SFA | -- | -- | R | R |
| MP, TH, | -- | -- | -- | R |
| LW, MU, APT | R | -- | -- | -- |
| COM, OFF, INS, PS | R | R | -- | -- |
Table Notes: SFD = Single-family detached; SFA = Single-family attached/Duplex; MP = Multiplex; TH = Townhouse; APT = Apartment; LW = Live-Work; MU = Mixed-Use; COM = Commercial; OFF = Office; INS = Institutional; PS = Parking Structure R = Bufferyard required | ||||
Table 10-2-4.2.1 Building Type Bufferyard Requirements | ||||
|---|---|---|---|---|
| District | SFD, SFA | MP, TH | LW, MU, APT | COM, OFF, INS, PS |
| SFD, SFA | -- | -- | R | R |
| MP, TH, | -- | -- | -- | R |
| LW, MU, APT | R | -- | -- | -- |
| COM, OFF, INS, PS | R | R | -- | -- |
Table Notes: SFD = Single-family detached; SFA = Single-family attached/Duplex; MP = Multiplex; TH = Townhouse; APT = Apartment; LW = Live-Work; MU = Mixed-Use; COM = Commercial; OFF = Office; INS = Institutional; PS = Parking Structure R = Bufferyard required | ||||
Effective on: 10/28/2021
Table 10-2-5.1.1 Sign Types by District | |||||
|---|---|---|---|---|---|
| DNR | DTA | DMS | DMU | Standards Reference | |
| Attached Signs | |||||
| Arcade | P | P | P | P | -- |
| Awning | -- | P | P | P | C.7 |
| Marquee | -- | -- | P1 | P1 | -- |
| Mural | -- | -- | P | P | C.8 |
| Projecting | -- | P | P | P | C.9 |
| Wall | P | P | P | P | C.10 |
| Window | P | P | P | P | C.11 |
| Detached Signs | |||||
| Monument | P | P | -- | P | -- |
| Pole | -- | P | -- | P | C.12 |
Table Notes:
| |||||
Table 10-2-5.1.1 Sign Types by District | |||||
|---|---|---|---|---|---|
| DNR | DTA | DMS | DMU | Standards Reference | |
| Attached Signs | |||||
| Arcade | P | P | P | P | -- |
| Awning | -- | P | P | P | C.7 |
| Marquee | -- | -- | P1 | P1 | -- |
| Mural | -- | -- | P | P | C.8 |
| Projecting | -- | P | P | P | C.9 |
| Wall | P | P | P | P | C.10 |
| Window | P | P | P | P | C.11 |
| Detached Signs | |||||
| Monument | P | P | -- | P | -- |
| Pole | -- | P | -- | P | C.12 |
Table Notes:
| |||||
Table 10-2-5.1.1 Sign Types by District | |||||
|---|---|---|---|---|---|
| DNR | DTA | DMS | DMU | Standards Reference | |
| Attached Signs | |||||
| Arcade | P | P | P | P | -- |
| Awning | -- | P | P | P | C.7 |
| Marquee | -- | -- | P1 | P1 | -- |
| Mural | -- | -- | P | P | C.8 |
| Projecting | -- | P | P | P | C.9 |
| Wall | P | P | P | P | C.10 |
| Window | P | P | P | P | C.11 |
| Detached Signs | |||||
| Monument | P | P | -- | P | -- |
| Pole | -- | P | -- | P | C.12 |
Table Notes:
| |||||
Table 10-2-5.1.1 Sign Types by District | |||||
|---|---|---|---|---|---|
| DNR | DTA | DMS | DMU | Standards Reference | |
| Attached Signs | |||||
| Arcade | P | P | P | P | -- |
| Awning | -- | P | P | P | C.7 |
| Marquee | -- | -- | P1 | P1 | -- |
| Mural | -- | -- | P | P | C.8 |
| Projecting | -- | P | P | P | C.9 |
| Wall | P | P | P | P | C.10 |
| Window | P | P | P | P | C.11 |
| Detached Signs | |||||
| Monument | P | P | -- | P | -- |
| Pole | -- | P | -- | P | C.12 |
Table Notes:
| |||||
Table 10-2-5.1.2 Attached Permanent Sign Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| DNR | DTA | DMS | DMU | |||||
| Arcade Sign | ||||||||
| Number Allowed | -- | -- | 1 per public entrance under arcade | |||||
| Maximum Area | -- | -- | 6 sq. ft. | |||||
| Minimum Clearance above Sidewalk | -- | -- | 8 ft. | |||||
| Illumination | -- | -- | External downlighting or halo | |||||
| Changeable Copy | -- | -- | Not permitted | |||||
| Awning Sign | ||||||||
| Number Allowed | -- | One per building façade or one per storefront for a mixed-use or multi-tenant building | ||||||
| Maximum Area | -- | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear foot of façade width, whichever is greatest1 | ||||||
| Minimum Vertical Clearance/ Maximum Height Above Grade | -- | 8 ft./ No higher than top of ground floor | ||||||
| Illumination | -- | External downlighting | ||||||
| Changeable Copy | -- | Not permitted | ||||||
| Marquee Signs | ||||||||
| Number Allowed | -- | -- | 1 per building front façade | |||||
| Maximum Area | -- | -- | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear foot of building front width, whichever is greatest1 | |||||
| Min./ Max. Clearance Above Grade | -- | -- | 12 ft./25 ft. | |||||
| Maximum Distance from Building Façade | -- | -- | 48 inches5 | |||||
| Illumination | -- | -- | Internal or halo | |||||
| Changeable Copy | -- | -- | Permitted | |||||
| Mural Sign | ||||||||
| Number Allowed | -- | -- | 1 per building façade | |||||
| Maximum Area | -- | -- | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear foot of building front width, whichever is greatest1 | |||||
| Maximum Height | -- | -- | Above ground floor but no higher than the roofline | |||||
| Illumination | -- | -- | External downlighting | |||||
| Changeable Copy | -- | -- | Not permitted | |||||
| Projecting Signs | ||||||||
| Number Allowed | -- | 1 per tenant per building frontage and 1 per tenant in the alley of the building, if applicable | ||||||
| Maximum Area | -- | 12 sq. ft. per face or 24 sq. ft. per sign | ||||||
| Min./Max. Clearance Above Grade | -- | 8 ft./No higher than the ground floor | ||||||
| Illumination | -- | Internal, halo, or downlight | ||||||
| Changeable Copy | -- | Not Permitted | ||||||
| Wall Signs4 | ||||||||
| Number Allowed | 1 per tenant per building frontage | |||||||
| Maximum Area/Sign | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of façade width occupied by an individual business, whichever is greatest1 | |||||||
| Max. Clearance Above Grade | No higher than roof or parapet line2 | |||||||
| Maximum Projection from Wall | 12 inches | |||||||
| Illumination | External downlighting, internal, or halo | |||||||
| Changeable Copy | Not Permitted | |||||||
| Other Standards | Wall signs professionally painted directly onto a wall are deemed mural signs | |||||||
| Window Signs | ||||||||
| Number Allowed | 1 per tenant per building frontage | |||||||
| Maximum Area | 10% of combined area of all windows | |||||||
| Max. Clearance Above Grade | No higher than roof or parapet line | |||||||
| Illumination | Internal with nighttime NITs level not to exceed 500 nits | |||||||
| Changeable Copy | Not permitted | Permitted3 | ||||||
Table Notes:
"--" = Sign type is not permitted | ||||||||
Table 10-2-5.1.2 Attached Permanent Sign Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| DNR | DTA | DMS | DMU | |||||
| Arcade Sign | ||||||||
| Number Allowed | -- | -- | 1 per public entrance under arcade | |||||
| Maximum Area | -- | -- | 6 sq. ft. | |||||
| Minimum Clearance above Sidewalk | -- | -- | 8 ft. | |||||
| Illumination | -- | -- | External downlighting or halo | |||||
| Changeable Copy | -- | -- | Not permitted | |||||
| Awning Sign | ||||||||
| Number Allowed | -- | One per building façade or one per storefront for a mixed-use or multi-tenant building | ||||||
| Maximum Area | -- | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear foot of façade width, whichever is greatest1 | ||||||
| Minimum Vertical Clearance/ Maximum Height Above Grade | -- | 8 ft./ No higher than top of ground floor | ||||||
| Illumination | -- | External downlighting | ||||||
| Changeable Copy | -- | Not permitted | ||||||
| Marquee Signs | ||||||||
| Number Allowed | -- | -- | 1 per building front façade | |||||
| Maximum Area | -- | -- | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear foot of building front width, whichever is greatest1 | |||||
| Min./ Max. Clearance Above Grade | -- | -- | 12 ft./25 ft. | |||||
| Maximum Distance from Building Façade | -- | -- | 48 inches5 | |||||
| Illumination | -- | -- | Internal or halo | |||||
| Changeable Copy | -- | -- | Permitted | |||||
| Mural Sign | ||||||||
| Number Allowed | -- | -- | 1 per building façade | |||||
| Maximum Area | -- | -- | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear foot of building front width, whichever is greatest1 | |||||
| Maximum Height | -- | -- | Above ground floor but no higher than the roofline | |||||
| Illumination | -- | -- | External downlighting | |||||
| Changeable Copy | -- | -- | Not permitted | |||||
| Projecting Signs | ||||||||
| Number Allowed | -- | 1 per tenant per building frontage and 1 per tenant in the alley of the building, if applicable | ||||||
| Maximum Area | -- | 12 sq. ft. per face or 24 sq. ft. per sign | ||||||
| Min./Max. Clearance Above Grade | -- | 8 ft./No higher than the ground floor | ||||||
| Illumination | -- | Internal, halo, or downlight | ||||||
| Changeable Copy | -- | Not Permitted | ||||||
| Wall Signs4 | ||||||||
| Number Allowed | 1 per tenant per building frontage | |||||||
| Maximum Area/Sign | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of façade width occupied by an individual business, whichever is greatest1 | |||||||
| Max. Clearance Above Grade | No higher than roof or parapet line2 | |||||||
| Maximum Projection from Wall | 12 inches | |||||||
| Illumination | External downlighting, internal, or halo | |||||||
| Changeable Copy | Not Permitted | |||||||
| Other Standards | Wall signs professionally painted directly onto a wall are deemed mural signs | |||||||
| Window Signs | ||||||||
| Number Allowed | 1 per tenant per building frontage | |||||||
| Maximum Area | 10% of combined area of all windows | |||||||
| Max. Clearance Above Grade | No higher than roof or parapet line | |||||||
| Illumination | Internal with nighttime NITs level not to exceed 500 nits | |||||||
| Changeable Copy | Not permitted | Permitted3 | ||||||
Table Notes:
"--" = Sign type is not permitted | ||||||||
Table 10-2-5.1.2 Attached Permanent Sign Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| DNR | DTA | DMS | DMU | |||||
| Arcade Sign | ||||||||
| Number Allowed | -- | -- | 1 per public entrance under arcade | |||||
| Maximum Area | -- | -- | 6 sq. ft. | |||||
| Minimum Clearance above Sidewalk | -- | -- | 8 ft. | |||||
| Illumination | -- | -- | External downlighting or halo | |||||
| Changeable Copy | -- | -- | Not permitted | |||||
| Awning Sign | ||||||||
| Number Allowed | -- | One per building façade or one per storefront for a mixed-use or multi-tenant building | ||||||
| Maximum Area | -- | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear foot of façade width, whichever is greatest1 | ||||||
| Minimum Vertical Clearance/ Maximum Height Above Grade | -- | 8 ft./ No higher than top of ground floor | ||||||
| Illumination | -- | External downlighting | ||||||
| Changeable Copy | -- | Not permitted | ||||||
| Marquee Signs | ||||||||
| Number Allowed | -- | -- | 1 per building front façade | |||||
| Maximum Area | -- | -- | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear foot of building front width, whichever is greatest1 | |||||
| Min./ Max. Clearance Above Grade | -- | -- | 12 ft./25 ft. | |||||
| Maximum Distance from Building Façade | -- | -- | 48 inches5 | |||||
| Illumination | -- | -- | Internal or halo | |||||
| Changeable Copy | -- | -- | Permitted | |||||
| Mural Sign | ||||||||
| Number Allowed | -- | -- | 1 per building façade | |||||
| Maximum Area | -- | -- | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear foot of building front width, whichever is greatest1 | |||||
| Maximum Height | -- | -- | Above ground floor but no higher than the roofline | |||||
| Illumination | -- | -- | External downlighting | |||||
| Changeable Copy | -- | -- | Not permitted | |||||
| Projecting Signs | ||||||||
| Number Allowed | -- | 1 per tenant per building frontage and 1 per tenant in the alley of the building, if applicable | ||||||
| Maximum Area | -- | 12 sq. ft. per face or 24 sq. ft. per sign | ||||||
| Min./Max. Clearance Above Grade | -- | 8 ft./No higher than the ground floor | ||||||
| Illumination | -- | Internal, halo, or downlight | ||||||
| Changeable Copy | -- | Not Permitted | ||||||
| Wall Signs4 | ||||||||
| Number Allowed | 1 per tenant per building frontage | |||||||
| Maximum Area/Sign | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of façade width occupied by an individual business, whichever is greatest1 | |||||||
| Max. Clearance Above Grade | No higher than roof or parapet line2 | |||||||
| Maximum Projection from Wall | 12 inches | |||||||
| Illumination | External downlighting, internal, or halo | |||||||
| Changeable Copy | Not Permitted | |||||||
| Other Standards | Wall signs professionally painted directly onto a wall are deemed mural signs | |||||||
| Window Signs | ||||||||
| Number Allowed | 1 per tenant per building frontage | |||||||
| Maximum Area | 10% of combined area of all windows | |||||||
| Max. Clearance Above Grade | No higher than roof or parapet line | |||||||
| Illumination | Internal with nighttime NITs level not to exceed 500 nits | |||||||
| Changeable Copy | Not permitted | Permitted3 | ||||||
Table Notes:
"--" = Sign type is not permitted | ||||||||
Table 10-2-5.1.2 Attached Permanent Sign Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| DNR | DTA | DMS | DMU | |||||
| Arcade Sign | ||||||||
| Number Allowed | -- | -- | 1 per public entrance under arcade | |||||
| Maximum Area | -- | -- | 6 sq. ft. | |||||
| Minimum Clearance above Sidewalk | -- | -- | 8 ft. | |||||
| Illumination | -- | -- | External downlighting or halo | |||||
| Changeable Copy | -- | -- | Not permitted | |||||
| Awning Sign | ||||||||
| Number Allowed | -- | One per building façade or one per storefront for a mixed-use or multi-tenant building | ||||||
| Maximum Area | -- | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear foot of façade width, whichever is greatest1 | ||||||
| Minimum Vertical Clearance/ Maximum Height Above Grade | -- | 8 ft./ No higher than top of ground floor | ||||||
| Illumination | -- | External downlighting | ||||||
| Changeable Copy | -- | Not permitted | ||||||
| Marquee Signs | ||||||||
| Number Allowed | -- | -- | 1 per building front façade | |||||
| Maximum Area | -- | -- | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear foot of building front width, whichever is greatest1 | |||||
| Min./ Max. Clearance Above Grade | -- | -- | 12 ft./25 ft. | |||||
| Maximum Distance from Building Façade | -- | -- | 48 inches5 | |||||
| Illumination | -- | -- | Internal or halo | |||||
| Changeable Copy | -- | -- | Permitted | |||||
| Mural Sign | ||||||||
| Number Allowed | -- | -- | 1 per building façade | |||||
| Maximum Area | -- | -- | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear foot of building front width, whichever is greatest1 | |||||
| Maximum Height | -- | -- | Above ground floor but no higher than the roofline | |||||
| Illumination | -- | -- | External downlighting | |||||
| Changeable Copy | -- | -- | Not permitted | |||||
| Projecting Signs | ||||||||
| Number Allowed | -- | 1 per tenant per building frontage and 1 per tenant in the alley of the building, if applicable | ||||||
| Maximum Area | -- | 12 sq. ft. per face or 24 sq. ft. per sign | ||||||
| Min./Max. Clearance Above Grade | -- | 8 ft./No higher than the ground floor | ||||||
| Illumination | -- | Internal, halo, or downlight | ||||||
| Changeable Copy | -- | Not Permitted | ||||||
| Wall Signs4 | ||||||||
| Number Allowed | 1 per tenant per building frontage | |||||||
| Maximum Area/Sign | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of façade width occupied by an individual business, whichever is greatest1 | |||||||
| Max. Clearance Above Grade | No higher than roof or parapet line2 | |||||||
| Maximum Projection from Wall | 12 inches | |||||||
| Illumination | External downlighting, internal, or halo | |||||||
| Changeable Copy | Not Permitted | |||||||
| Other Standards | Wall signs professionally painted directly onto a wall are deemed mural signs | |||||||
| Window Signs | ||||||||
| Number Allowed | 1 per tenant per building frontage | |||||||
| Maximum Area | 10% of combined area of all windows | |||||||
| Max. Clearance Above Grade | No higher than roof or parapet line | |||||||
| Illumination | Internal with nighttime NITs level not to exceed 500 nits | |||||||
| Changeable Copy | Not permitted | Permitted3 | ||||||
Table Notes:
"--" = Sign type is not permitted | ||||||||
Table 10-2-5.1.3 Detached Permanent Sign Standards | ||||
|---|---|---|---|---|
| DNR | DTA | DMS | DMU | |
| Monument Sign | ||||
| Number Allowed | 1 per street frontage |
| ||
| Maximum Area | 40 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width, whichever is greater1 | |||
| Maximum Height Above Grade | 5 ft. | 8 ft. | ||
| Illumination | Internally lit, Halo lit, or Externally downlit | |||
| Changeable Copy | Not permitted | Permitted2 | ||
| Pole Sign | ||||
| Number Allowed | -- | 1 per street frontage | -- | 1 per street frontage |
| Maximum Area | -- | 40 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width, whichever is greater1 | -- | 40 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width, whichever is greater1 |
| Maximum Height Above Grade | -- | 15 ft. | -- | 15 ft. |
| Illumination | -- | Halo | -- | Halo |
| Changeable Copy | -- | Not permitted | -- | Not permitted |
Table Notes:
"--" = The sign type is not permitted. | ||||
Table 10-2-5.1.3 Detached Permanent Sign Standards | ||||
|---|---|---|---|---|
| DNR | DTA | DMS | DMU | |
| Monument Sign | ||||
| Number Allowed | 1 per street frontage |
| ||
| Maximum Area | 40 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width, whichever is greater1 | |||
| Maximum Height Above Grade | 5 ft. | 8 ft. | ||
| Illumination | Internally lit, Halo lit, or Externally downlit | |||
| Changeable Copy | Not permitted | Permitted2 | ||
| Pole Sign | ||||
| Number Allowed | -- | 1 per street frontage | -- | 1 per street frontage |
| Maximum Area | -- | 40 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width, whichever is greater1 | -- | 40 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width, whichever is greater1 |
| Maximum Height Above Grade | -- | 15 ft. | -- | 15 ft. |
| Illumination | -- | Halo | -- | Halo |
| Changeable Copy | -- | Not permitted | -- | Not permitted |
Table Notes:
"--" = The sign type is not permitted. | ||||
Table 10-2-5.1.3 Detached Permanent Sign Standards | ||||
|---|---|---|---|---|
| DNR | DTA | DMS | DMU | |
| Monument Sign | ||||
| Number Allowed | 1 per street frontage |
| ||
| Maximum Area | 40 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width, whichever is greater1 | |||
| Maximum Height Above Grade | 5 ft. | 8 ft. | ||
| Illumination | Internally lit, Halo lit, or Externally downlit | |||
| Changeable Copy | Not permitted | Permitted2 | ||
| Pole Sign | ||||
| Number Allowed | -- | 1 per street frontage | -- | 1 per street frontage |
| Maximum Area | -- | 40 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width, whichever is greater1 | -- | 40 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width, whichever is greater1 |
| Maximum Height Above Grade | -- | 15 ft. | -- | 15 ft. |
| Illumination | -- | Halo | -- | Halo |
| Changeable Copy | -- | Not permitted | -- | Not permitted |
Table Notes:
"--" = The sign type is not permitted. | ||||
Table 10-2-5.1.3 Detached Permanent Sign Standards | ||||
|---|---|---|---|---|
| DNR | DTA | DMS | DMU | |
| Monument Sign | ||||
| Number Allowed | 1 per street frontage |
| ||
| Maximum Area | 40 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width, whichever is greater1 | |||
| Maximum Height Above Grade | 5 ft. | 8 ft. | ||
| Illumination | Internally lit, Halo lit, or Externally downlit | |||
| Changeable Copy | Not permitted | Permitted2 | ||
| Pole Sign | ||||
| Number Allowed | -- | 1 per street frontage | -- | 1 per street frontage |
| Maximum Area | -- | 40 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width, whichever is greater1 | -- | 40 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width, whichever is greater1 |
| Maximum Height Above Grade | -- | 15 ft. | -- | 15 ft. |
| Illumination | -- | Halo | -- | Halo |
| Changeable Copy | -- | Not permitted | -- | Not permitted |
Table Notes:
"--" = The sign type is not permitted. | ||||
(Ord. 18, Series of 2022; Ord. 20, Series of 2023)
Effective on: 10/13/2023
Figure 10-2-3.2.1 Single-Family Detached Building Type | |||||
|---|---|---|---|---|---|
![]() | |||||
![]()
| Primary entrance is oriented to the street and often defined by a porch. | ![]() | Some portion of the roof is pitched | ![]() | Walkway leads to the primary entrance from the public way. |
![]() | Autos access the property either from the alley or the street (where permitted) | ||||
Figure 10-2-3.2.1 Single-Family Detached Building Type | |||||
|---|---|---|---|---|---|
![]() | |||||
![]()
| Primary entrance is oriented to the street and often defined by a porch. | ![]() | Some portion of the roof is pitched | ![]() | Walkway leads to the primary entrance from the public way. |
![]() | Autos access the property either from the alley or the street (where permitted) | ||||
Figure 10-2-3.2.1 Single-Family Detached Building Type | |||||
|---|---|---|---|---|---|
![]() | |||||
![]()
| Primary entrance is oriented to the street and often defined by a porch. | ![]() | Some portion of the roof is pitched | ![]() | Walkway leads to the primary entrance from the public way. |
![]() | Autos access the property either from the alley or the street (where permitted) | ||||
Figure 10-2-3.2.1 Single-Family Detached Building Type | |||||
|---|---|---|---|---|---|
![]() | |||||
![]()
| Primary entrance is oriented to the street and often defined by a porch. | ![]() | Some portion of the roof is pitched | ![]() | Walkway leads to the primary entrance from the public way. |
![]() | Autos access the property either from the alley or the street (where permitted) | ||||
THE SAMPLE IMAGES BELOW ARE SHOWN ONLY FOR ILLUSTRATIVE PURPOSES AND ARE NOT MEANT TO PRESCRIBE THAT THESE FORMS MUST BE USED. | ||
|---|---|---|
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
Figure 10-2-3.2.2 Single-Family Detached Building Type (see Table 10-2-3.2.2, below) | |
|---|---|
![]() | ![]() |
| Building Placement and Building Coverage | Building Height and Upper Story Stepbacks |
![]() | ![]() |
| Building Activation | Building Form and Orientation |
Table 10-2-3.2.2 Single-Family Detached Building Type Standards (see Figure 10-2-3.2.2 above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 10’ / 20’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min. ft.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 65% | 65% | N/A | 70% |
| G | Public or Private Open Space and Tree Canopy Coverage (min. %) | 35% | 35% | N/A | 30% |
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | N/A | N/A | N/A |
| B | Maximum Height (number of stories/feet) | 2.5 / 30’ | 2.5 / 30’ | N/A | 2.5 / 30’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | N/A | N/A | N/A |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | N/A | N/A | N/A | N/A |
| Street Facing Wall Articulation | |||||
| C | Maximum façade width before articulation | 30’ | 30' | N/A | 30’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 1 | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques required (refer to Table 10-1-3.1.B for technique options) | N/A | N/A | N/A | N/A |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | N/A | N/A | N/A |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | N/A | N/A | N/A |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) percentage of building in plan view | 50% | 50% | N/A | 50% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Table 10-2-3.2.2 Single-Family Detached Building Type Standards (see Figure 10-2-3.2.2 above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 10’ / 20’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min. ft.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 65% | 65% | N/A | 70% |
| G | Public or Private Open Space and Tree Canopy Coverage (min. %) | 35% | 35% | N/A | 30% |
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | N/A | N/A | N/A |
| B | Maximum Height (number of stories/feet) | 2.5 / 30’ | 2.5 / 30’ | N/A | 2.5 / 30’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | N/A | N/A | N/A |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | N/A | N/A | N/A | N/A |
| Street Facing Wall Articulation | |||||
| C | Maximum façade width before articulation | 30’ | 30' | N/A | 30’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 1 | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques required (refer to Table 10-1-3.1.B for technique options) | N/A | N/A | N/A | N/A |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | N/A | N/A | N/A |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | N/A | N/A | N/A |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) percentage of building in plan view | 50% | 50% | N/A | 50% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Table 10-2-3.2.2 Single-Family Detached Building Type Standards (see Figure 10-2-3.2.2 above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 10’ / 20’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min. ft.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 65% | 65% | N/A | 70% |
| G | Public or Private Open Space and Tree Canopy Coverage (min. %) | 35% | 35% | N/A | 30% |
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | N/A | N/A | N/A |
| B | Maximum Height (number of stories/feet) | 2.5 / 30’ | 2.5 / 30’ | N/A | 2.5 / 30’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | N/A | N/A | N/A |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | N/A | N/A | N/A | N/A |
| Street Facing Wall Articulation | |||||
| C | Maximum façade width before articulation | 30’ | 30' | N/A | 30’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 1 | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques required (refer to Table 10-1-3.1.B for technique options) | N/A | N/A | N/A | N/A |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | N/A | N/A | N/A |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | N/A | N/A | N/A |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) percentage of building in plan view | 50% | 50% | N/A | 50% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Table 10-2-3.2.2 Single-Family Detached Building Type Standards (see Figure 10-2-3.2.2 above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 10’ / 20’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min. ft.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 65% | 65% | N/A | 70% |
| G | Public or Private Open Space and Tree Canopy Coverage (min. %) | 35% | 35% | N/A | 30% |
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | N/A | N/A | N/A |
| B | Maximum Height (number of stories/feet) | 2.5 / 30’ | 2.5 / 30’ | N/A | 2.5 / 30’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | N/A | N/A | N/A |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | N/A | N/A | N/A | N/A |
| Street Facing Wall Articulation | |||||
| C | Maximum façade width before articulation | 30’ | 30' | N/A | 30’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 1 | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques required (refer to Table 10-1-3.1.B for technique options) | N/A | N/A | N/A | N/A |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | N/A | N/A | N/A |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | N/A | N/A | N/A |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) percentage of building in plan view | 50% | 50% | N/A | 50% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Effective on: 1/1/1901
Figure 10-2-3.2.3 Single-Family Attached / Duplex Building Type | |||||
|---|---|---|---|---|---|
![]() | |||||
![]() | Primary entrance is oriented to the street and may be defined by a porch. | ![]() | Parking is subordinate to the primary building. | ![]() | Walkway leads to the primary entrance from the public way. |
| THE SAMPLE IMAGES BELOW ARE SHOWN ONLY FOR ILLUSTRATIVE PURPOSES AND ARE NOT MEANT TO PRESCRIBE THAT THESE FORMS MUST BE USED. | ||
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
Figure 10-2-3.2.4 Single-Family Attached / Duplex Building Type (see Table 10-2-3.2.3, below) | |
|---|---|
![]() | ![]() |
| Building Placement and Building Coverage | Building Height and Upper Story Stepbacks |
![]() |
![]() |
| Building Activation | Building Form and Orientation |
Table 10-2-3.2.3 Single-Family Attached / Duplex Building Type Standards (see Figure 10-2-3.2.4, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 20’ / 30’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min. ft.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5 |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 60% | 60% | N/A | 60% |
| G | Public or Private Open Space and Tree Canopy Coverage (min. %) | 30% | 30% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | 1 | N/A | N/A |
| B | Maximum Height (number of stories/feet) | 2.5 / 30’ | 2.5 / 30’ | N/A | 2.5 / 30’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | N/A | N/A | N/A |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | 30’ | 30’ | N/A | 30’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | 25’ | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 1 | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques required (refer to Table 10-1-3.1.B for technique options) | N/A | N/A | N/A | N/A |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | N/A | N/A | N/A |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | N/A | N/A | N/A |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) percentage of topmost floor | 50% | 50% | N/A | 50% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Table 10-2-3.2.3 Single-Family Attached / Duplex Building Type Standards (see Figure 10-2-3.2.4, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 20’ / 30’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min. ft.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5 |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 60% | 60% | N/A | 60% |
| G | Public or Private Open Space and Tree Canopy Coverage (min. %) | 30% | 30% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | 1 | N/A | N/A |
| B | Maximum Height (number of stories/feet) | 2.5 / 30’ | 2.5 / 30’ | N/A | 2.5 / 30’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | N/A | N/A | N/A |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | 30’ | 30’ | N/A | 30’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | 25’ | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 1 | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques required (refer to Table 10-1-3.1.B for technique options) | N/A | N/A | N/A | N/A |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | N/A | N/A | N/A |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | N/A | N/A | N/A |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) percentage of topmost floor | 50% | 50% | N/A | 50% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Table 10-2-3.2.3 Single-Family Attached / Duplex Building Type Standards (see Figure 10-2-3.2.4, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 20’ / 30’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min. ft.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5 |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 60% | 60% | N/A | 60% |
| G | Public or Private Open Space and Tree Canopy Coverage (min. %) | 30% | 30% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | 1 | N/A | N/A |
| B | Maximum Height (number of stories/feet) | 2.5 / 30’ | 2.5 / 30’ | N/A | 2.5 / 30’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | N/A | N/A | N/A |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | 30’ | 30’ | N/A | 30’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | 25’ | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 1 | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques required (refer to Table 10-1-3.1.B for technique options) | N/A | N/A | N/A | N/A |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | N/A | N/A | N/A |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | N/A | N/A | N/A |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) percentage of topmost floor | 50% | 50% | N/A | 50% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Table 10-2-3.2.3 Single-Family Attached / Duplex Building Type Standards (see Figure 10-2-3.2.4, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 20’ / 30’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min. ft.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5 |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 60% | 60% | N/A | 60% |
| G | Public or Private Open Space and Tree Canopy Coverage (min. %) | 30% | 30% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | 1 | N/A | N/A |
| B | Maximum Height (number of stories/feet) | 2.5 / 30’ | 2.5 / 30’ | N/A | 2.5 / 30’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | N/A | N/A | N/A |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | 30’ | 30’ | N/A | 30’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | 25’ | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 1 | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques required (refer to Table 10-1-3.1.B for technique options) | N/A | N/A | N/A | N/A |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | N/A | N/A | N/A |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | N/A | N/A | N/A |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) percentage of topmost floor | 50% | 50% | N/A | 50% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Effective on: 1/1/1901
Figure 10-2-3.2.5 Multiplex Building Type | |||||
|---|---|---|---|---|---|
![]() | |||||
![]() | Primary entrance is oriented to the street and may be defined by a porch. | ![]() | Pitched roof relates to traditional single-family buildings. | ![]() | Walkway leads to the primary entrance from the public way. |
| THE SAMPLE IMAGES BELOW ARE SHOWN ONLY FOR ILLUSTRATIVE PURPOSES AND ARE NOT MEANT TO PRESCRIBE THAT THESE FORMS MUST BE USED. | ||
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
Figure 10-2-3.2.6 Multiplex Building Type (see Table 10-2-3.2.4, below) | |
|---|---|
![]() | ![]() |
| Building Placement and Building Coverage | Building Height and Upper Story Stepbacks |
![]() |
![]() |
| Building Activation | Building Form and Orientation |
Table 10-2-3.2.4 Multiplex Building Type Standards (see Figure 10-2-3.2.6, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 20’ / 30’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min. ft.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 70% | 70% | N/A | 70% |
| G | Public Amenity / Outdoor Space and Tree Canopy Coverage (min. %) | 25% | 25% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | 2.5 / 30’ | 2.5 / 30' | N/A | 2.5 / 30' |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 20 ft. of a sensitive edge | N/A | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | 15’ | 15’ | N/A | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum wall length before articulation | 25’ | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 2 | 1 | N/A | 2 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | 2 | 1 | N/A | 2 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | 30% | 30% | N/A | 30% |
| G | Façade glazed: % upper floor(s) wall area (min.) | 20% | 20% | N/A | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) as percentage of building in plan view if not an art-deco or contemporary architectural style | 50% | 50% | N/A | 25% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation requirement | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Table 10-2-3.2.4 Multiplex Building Type Standards (see Figure 10-2-3.2.6, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 20’ / 30’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min. ft.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 70% | 70% | N/A | 70% |
| G | Public Amenity / Outdoor Space and Tree Canopy Coverage (min. %) | 25% | 25% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | 2.5 / 30’ | 2.5 / 30' | N/A | 2.5 / 30' |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 20 ft. of a sensitive edge | N/A | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | 15’ | 15’ | N/A | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum wall length before articulation | 25’ | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 2 | 1 | N/A | 2 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | 2 | 1 | N/A | 2 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | 30% | 30% | N/A | 30% |
| G | Façade glazed: % upper floor(s) wall area (min.) | 20% | 20% | N/A | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) as percentage of building in plan view if not an art-deco or contemporary architectural style | 50% | 50% | N/A | 25% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation requirement | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Table 10-2-3.2.4 Multiplex Building Type Standards (see Figure 10-2-3.2.6, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 20’ / 30’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min. ft.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 70% | 70% | N/A | 70% |
| G | Public Amenity / Outdoor Space and Tree Canopy Coverage (min. %) | 25% | 25% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | 2.5 / 30’ | 2.5 / 30' | N/A | 2.5 / 30' |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 20 ft. of a sensitive edge | N/A | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | 15’ | 15’ | N/A | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum wall length before articulation | 25’ | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 2 | 1 | N/A | 2 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | 2 | 1 | N/A | 2 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | 30% | 30% | N/A | 30% |
| G | Façade glazed: % upper floor(s) wall area (min.) | 20% | 20% | N/A | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) as percentage of building in plan view if not an art-deco or contemporary architectural style | 50% | 50% | N/A | 25% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation requirement | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Table 10-2-3.2.4 Multiplex Building Type Standards (see Figure 10-2-3.2.6, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 20’ / 30’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min. ft.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 70% | 70% | N/A | 70% |
| G | Public Amenity / Outdoor Space and Tree Canopy Coverage (min. %) | 25% | 25% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | 2.5 / 30’ | 2.5 / 30' | N/A | 2.5 / 30' |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 20 ft. of a sensitive edge | N/A | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | 15’ | 15’ | N/A | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum wall length before articulation | 25’ | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 2 | 1 | N/A | 2 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | 2 | 1 | N/A | 2 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | 30% | 30% | N/A | 30% |
| G | Façade glazed: % upper floor(s) wall area (min.) | 20% | 20% | N/A | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) as percentage of building in plan view if not an art-deco or contemporary architectural style | 50% | 50% | N/A | 25% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation requirement | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
(There are no ordinances associated with this section.)
Effective on: 10/13/2023
Description. This building type accommodates three to eight single-family units which are attached to one another and are oriented to the street. They are to be compatible in mass and scale with nearby residential structures of a lower scale. A Townhouse is one to three stories in height. The façade is designed to express each individual unit. Each unit has a principal entrance on the ground floor defined by a porch, stoop, or recessed entry. End units have window openings on three sides, while interior units have window openings only in the front and back. Parking is located in the rear. Figure 10-2-3.2.7, Townhouse Building Type, illustrates this building type.
Figure 10-2-3.2.7 Townhouse Building Type | |||||
|---|---|---|---|---|---|
![]() | |||||
![]() | Walkway leads to the primary entrance from the public way | ![]() | Articulation techniques provide variety in scale and add visual interest | ![]() | A primary entrance may be defined by a covered porch, stoop, or covered entry. |
| THE SAMPLE IMAGES BELOW ARE SHOWN ONLY FOR ILLUSTRATIVE PURPOSES AND ARE NOT MEANT TO PRESCRIBE THAT THESE FORMS MUST BE USED. | |
![]() | ![]() |
![]() | ![]() |
Figure 10-2-3.2.8 Townhouse Building Type (see Table 10-2-3.2.5, below) | |
|---|---|
![]() | ![]() |
| Building Placement and Building Coverage | Building Height and Upper Story Stepbacks |
![]() |
![]() |
| Building Activation | Building Form and Orientation |
Table 10-2-3.2.5 Townhouse Building Type Standards (see Figure 10-2-3.2.8 above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 20’ / 30’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 70% | 70% | N/A | 70% |
| G | Public Amenity / Open Space and Tree Canopy Coverage (min. %) | 25% | 25% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | 2.5 / 30' | 3 / 45’ | N/A | 3 / 45’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 20 ft. of a sensitive edge | 2 | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | 125’ | 125’ | N/A | 125’ |
| B | Blank Wall (max. ft.) | 15’ | 15’ | N/A | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | 25’ | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 1 | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | 1 | 1 | N/A | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | 30% | 30% | N/A | 30% |
| G | Façade glazed: % upper floor(s) wall area (min.) | 20% | 20% | N/A | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) percentage of topmost floor | 25% | 25% | N/A | 25% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Table 10-2-3.2.5 Townhouse Building Type Standards (see Figure 10-2-3.2.8 above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 20’ / 30’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 70% | 70% | N/A | 70% |
| G | Public Amenity / Open Space and Tree Canopy Coverage (min. %) | 25% | 25% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | 2.5 / 30' | 3 / 45’ | N/A | 3 / 45’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 20 ft. of a sensitive edge | 2 | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | 125’ | 125’ | N/A | 125’ |
| B | Blank Wall (max. ft.) | 15’ | 15’ | N/A | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | 25’ | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 1 | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | 1 | 1 | N/A | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | 30% | 30% | N/A | 30% |
| G | Façade glazed: % upper floor(s) wall area (min.) | 20% | 20% | N/A | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) percentage of topmost floor | 25% | 25% | N/A | 25% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Table 10-2-3.2.5 Townhouse Building Type Standards (see Figure 10-2-3.2.8 above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 20’ / 30’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 70% | 70% | N/A | 70% |
| G | Public Amenity / Open Space and Tree Canopy Coverage (min. %) | 25% | 25% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | 2.5 / 30' | 3 / 45’ | N/A | 3 / 45’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 20 ft. of a sensitive edge | 2 | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | 125’ | 125’ | N/A | 125’ |
| B | Blank Wall (max. ft.) | 15’ | 15’ | N/A | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | 25’ | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 1 | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | 1 | 1 | N/A | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | 30% | 30% | N/A | 30% |
| G | Façade glazed: % upper floor(s) wall area (min.) | 20% | 20% | N/A | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) percentage of topmost floor | 25% | 25% | N/A | 25% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Table 10-2-3.2.5 Townhouse Building Type Standards (see Figure 10-2-3.2.8 above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 20’ / 30’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 70% | 70% | N/A | 70% |
| G | Public Amenity / Open Space and Tree Canopy Coverage (min. %) | 25% | 25% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | 2.5 / 30' | 3 / 45’ | N/A | 3 / 45’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 20 ft. of a sensitive edge | 2 | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | 125’ | 125’ | N/A | 125’ |
| B | Blank Wall (max. ft.) | 15’ | 15’ | N/A | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | 25’ | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 1 | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | 1 | 1 | N/A | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | 30% | 30% | N/A | 30% |
| G | Façade glazed: % upper floor(s) wall area (min.) | 20% | 20% | N/A | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) percentage of topmost floor | 25% | 25% | N/A | 25% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Effective on: 1/1/1901
Figure 10-2-3.2.9 Apartment Building Type | |||||
|---|---|---|---|---|---|
![]() | |||||
![]() | Primary entrance orients to the street or a shared open space. | ![]() | Variation in massing and wall articulation provides visual interest and reduces perceived mass. | ![]() | Windows provide a sense of connection to the public way. |
| THE SAMPLE IMAGES BELOW ARE SHOWN ONLY FOR ILLUSTRATIVE PURPOSES AND ARE NOT MEANT TO PRESCRIBE THAT THESE FORMS MUST BE USED. | |
![]() | ![]() |
![]() | ![]() |
Figure 10-2-3.2.10 Apartment Building Type (see Table 10-2-3.2.6, below) | |
|---|---|
![]() | ![]() |
| Building Placement and Building Coverage | Building Height and Upper Story Stepbacks |
![]() | ![]() |
| Building Activation | Building Form and Orientation |
Table 10-2-3.2.6 Apartment Building Type Standards (see Figure 10-2-3.2.10, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 10’ / 30’ | N/A | 5’ / 20’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min.) | N/A | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 5’ | N/A | 5’ |
E | Rear Setback (min. ft. / min. ft. with alley)1 | N/A | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | N/A | 65% | N/A | 75% |
| G | Public Amenity / Outdoor Space and Tree Canopy Coverage (min. %) | N/A | 35% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | N/A | 4 / 55'’* |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | 80% |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 14’ | N/A | 14’ |
| *A maximum of four stories is permitted in the DMU character area that lies between Church Avenue and Alamo Avenue (but not abutting Alamo), and north of Berry Avenue, except in the white hatched area of the Character Map, where the maximum height is three stories / 45’. | |||||
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 125’ | N/A | 125’ |
| B | Blank Wall (max. ft.) | N/A | 20’ | N/A | 20’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | N/A | 3 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | N/A | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 40% | N/A | 40% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 30% | N/A | 30% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) as a percentage of building in plan view | N/A | 25% | N/A | N/A |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | N/A | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | 50’ | N/A | 50’ |
Table 10-2-3.2.6 Apartment Building Type Standards (see Figure 10-2-3.2.10, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 10’ / 30’ | N/A | 5’ / 20’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min.) | N/A | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 5’ | N/A | 5’ |
E | Rear Setback (min. ft. / min. ft. with alley)1 | N/A | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | N/A | 65% | N/A | 75% |
| G | Public Amenity / Outdoor Space and Tree Canopy Coverage (min. %) | N/A | 35% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | N/A | 4 / 55'’* |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | 80% |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 14’ | N/A | 14’ |
| *A maximum of four stories is permitted in the DMU character area that lies between Church Avenue and Alamo Avenue (but not abutting Alamo), and north of Berry Avenue, except in the white hatched area of the Character Map, where the maximum height is three stories / 45’. | |||||
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 125’ | N/A | 125’ |
| B | Blank Wall (max. ft.) | N/A | 20’ | N/A | 20’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | N/A | 3 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | N/A | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 40% | N/A | 40% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 30% | N/A | 30% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) as a percentage of building in plan view | N/A | 25% | N/A | N/A |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | N/A | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | 50’ | N/A | 50’ |
Table 10-2-3.2.6 Apartment Building Type Standards (see Figure 10-2-3.2.10, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 10’ / 30’ | N/A | 5’ / 20’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min.) | N/A | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 5’ | N/A | 5’ |
E | Rear Setback (min. ft. / min. ft. with alley)1 | N/A | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | N/A | 65% | N/A | 75% |
| G | Public Amenity / Outdoor Space and Tree Canopy Coverage (min. %) | N/A | 35% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | N/A | 4 / 55'’* |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | 80% |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 14’ | N/A | 14’ |
| *A maximum of four stories is permitted in the DMU character area that lies between Church Avenue and Alamo Avenue (but not abutting Alamo), and north of Berry Avenue, except in the white hatched area of the Character Map, where the maximum height is three stories / 45’. | |||||
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 125’ | N/A | 125’ |
| B | Blank Wall (max. ft.) | N/A | 20’ | N/A | 20’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | N/A | 3 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | N/A | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 40% | N/A | 40% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 30% | N/A | 30% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) as a percentage of building in plan view | N/A | 25% | N/A | N/A |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | N/A | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | 50’ | N/A | 50’ |
Table 10-2-3.2.6 Apartment Building Type Standards (see Figure 10-2-3.2.10, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 10’ / 30’ | N/A | 5’ / 20’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min.) | N/A | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 5’ | N/A | 5’ |
E | Rear Setback (min. ft. / min. ft. with alley)1 | N/A | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | N/A | 65% | N/A | 75% |
| G | Public Amenity / Outdoor Space and Tree Canopy Coverage (min. %) | N/A | 35% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | N/A | 4 / 55'’* |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | 80% |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 14’ | N/A | 14’ |
| *A maximum of four stories is permitted in the DMU character area that lies between Church Avenue and Alamo Avenue (but not abutting Alamo), and north of Berry Avenue, except in the white hatched area of the Character Map, where the maximum height is three stories / 45’. | |||||
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 125’ | N/A | 125’ |
| B | Blank Wall (max. ft.) | N/A | 20’ | N/A | 20’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | N/A | 3 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | N/A | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 40% | N/A | 40% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 30% | N/A | 30% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) as a percentage of building in plan view | N/A | 25% | N/A | N/A |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | N/A | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | 50’ | N/A | 50’ |
Effective on: 1/1/1901
Figure 10-2-3.2.11 Live-Work Building Type | |||||
|---|---|---|---|---|---|
![]() | |||||
![]() | An easily identifiable entrance to the building. | ![]() | Step back of the upper floor reduces perceived mass. | ![]() | Transparency at the ground level engages the public way. |
| THE SAMPLE IMAGES BELOW ARE SHOWN ONLY FOR ILLUSTRATIVE PURPOSES AND ARE NOT MEANT TO PRESCRIBE THAT THESE FORMS MUST BE USED. | ||
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
Figure 10-2-3.2.12 Live-Work Building Type (see Table 10-2-3.2.7, below) | |
|---|---|
![]() | ![]() |
| Building Placement and Building Coverage | Building Height and Upper Story Stepbacks |
![]() | ![]() |
| Building Activation | Building Form and Orientation |
Table 10-2-3.2.7 Live-Work Building Type Standards (see Figure 10-2-3.2.12, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 5’ / 10’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 70% / 70% | N/A | 90% / 90% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 0’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | N/A | 10’ / 20' | N/A | 0’ ' 20' |
| F | Building Coverage (max. %) | N/A | 70% | N/A | 80% |
| G | Public Amenity / Open Space and Tree Canopy Coverage (min. %) | N/A | 30% | N/A | 20% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | N/A | 3 / 45’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 14’ | N/A | 14’ |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 125’ | N/A | 125’ |
| B | Blank Wall (max. ft.) | N/A | 20’ | N/A | 20’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | N/A | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 50% | N/A | 50% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 30% | N/A | 30% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | 50% | N/A | 50% |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | 50’ | N/A | 50’ |
Table 10-2-3.2.7 Live-Work Building Type Standards (see Figure 10-2-3.2.12, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 5’ / 10’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 70% / 70% | N/A | 90% / 90% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 0’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | N/A | 10’ / 20' | N/A | 0’ ' 20' |
| F | Building Coverage (max. %) | N/A | 70% | N/A | 80% |
| G | Public Amenity / Open Space and Tree Canopy Coverage (min. %) | N/A | 30% | N/A | 20% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | N/A | 3 / 45’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 14’ | N/A | 14’ |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 125’ | N/A | 125’ |
| B | Blank Wall (max. ft.) | N/A | 20’ | N/A | 20’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | N/A | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 50% | N/A | 50% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 30% | N/A | 30% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | 50% | N/A | 50% |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | 50’ | N/A | 50’ |
Table 10-2-3.2.7 Live-Work Building Type Standards (see Figure 10-2-3.2.12, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 5’ / 10’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 70% / 70% | N/A | 90% / 90% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 0’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | N/A | 10’ / 20' | N/A | 0’ ' 20' |
| F | Building Coverage (max. %) | N/A | 70% | N/A | 80% |
| G | Public Amenity / Open Space and Tree Canopy Coverage (min. %) | N/A | 30% | N/A | 20% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | N/A | 3 / 45’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 14’ | N/A | 14’ |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 125’ | N/A | 125’ |
| B | Blank Wall (max. ft.) | N/A | 20’ | N/A | 20’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | N/A | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 50% | N/A | 50% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 30% | N/A | 30% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | 50% | N/A | 50% |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | 50’ | N/A | 50’ |
Table 10-2-3.2.7 Live-Work Building Type Standards (see Figure 10-2-3.2.12, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 5’ / 10’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 70% / 70% | N/A | 90% / 90% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 0’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | N/A | 10’ / 20' | N/A | 0’ ' 20' |
| F | Building Coverage (max. %) | N/A | 70% | N/A | 80% |
| G | Public Amenity / Open Space and Tree Canopy Coverage (min. %) | N/A | 30% | N/A | 20% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | N/A | 3 / 45’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 14’ | N/A | 14’ |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 125’ | N/A | 125’ |
| B | Blank Wall (max. ft.) | N/A | 20’ | N/A | 20’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | N/A | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 50% | N/A | 50% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 30% | N/A | 30% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | 50% | N/A | 50% |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | 50’ | N/A | 50’ |
Effective on: 1/1/1901
Figure 10-2-3.2.12 Mixed-Use Building Type | |||||
|---|---|---|---|---|---|
![]() | |||||
![]() | An easily identifiable entrance to the building. | ![]() | Step back of the upper floor reduces perceived mass. | ![]() | Transparency at the ground level engages the public way. |
| THE SAMPLE IMAGES BELOW ARE SHOWN ONLY FOR ILLUSTRATIVE PURPOSES AND ARE NOT MEANT TO PRESCRIBE THAT THESE FORMS MUST BE USED. | ||
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
Figure 10-2-3.2.13 Mixed-Use Building Type (see Table 10-2-3.2.8, below) | |
|---|---|
![]() | ![]() |
| Building Placement and Building Coverage | Building Height and Upper Story Stepbacks |
![]() | ![]() |
| Building Activation | Building Form and Orientation |
Table 10-2-3.2.8 Mixed-Use Building Type Standards (see Figure 10-2-3.2.13, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 10’ / 20’ | 0’ / 5’ | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 70% / 70% | 80% / 80% | 80% / 80% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 0’ | 0’ | 10’ |
| D | Interior Lot Side Setback (min. ft.) | N/A | 0’ | 0’ | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | N/A | 10' / 10’ | 0’ / 10' | 0' / 10’ |
| F | Building Coverage (max. %) | N/A | 75% | 90% | 90% |
| G | Public Amenity / Open Space and Tree Canopy Coverage (min. %) | N/A | 25% | 0% | 10% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | 2 | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 4' / 55' | 3 / 45’ | 4 / 55' |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | 65% | N/A | 80% |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | 2 | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 15' | 15' | 15' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 150’ | 150’ | 150’ |
| B | Blank Wall (max. ft.) | N/A | 20’ | 20’ | 20’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade width before articulation is required (refer to Table 10-1-3.1.A for technique options) | N/A | 25’ | 25’ | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | 2 | 2 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques required | N/A | 1 | 1 | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 65% | 70% | 65% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 25% | 20% | 25% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | 25% | N/A | 25% |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | ||
| C | Primary entrance spacing (max.) | N/A | 50’ | 50’ | 50’ |
Table 10-2-3.2.8 Mixed-Use Building Type Standards (see Figure 10-2-3.2.13, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 10’ / 20’ | 0’ / 5’ | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 70% / 70% | 80% / 80% | 80% / 80% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 0’ | 0’ | 10’ |
| D | Interior Lot Side Setback (min. ft.) | N/A | 0’ | 0’ | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | N/A | 10' / 10’ | 0’ / 10' | 0' / 10’ |
| F | Building Coverage (max. %) | N/A | 75% | 90% | 90% |
| G | Public Amenity / Open Space and Tree Canopy Coverage (min. %) | N/A | 25% | 0% | 10% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | 2 | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 4' / 55' | 3 / 45’ | 4 / 55' |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | 65% | N/A | 80% |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | 2 | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 15' | 15' | 15' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 150’ | 150’ | 150’ |
| B | Blank Wall (max. ft.) | N/A | 20’ | 20’ | 20’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade width before articulation is required (refer to Table 10-1-3.1.A for technique options) | N/A | 25’ | 25’ | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | 2 | 2 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques required | N/A | 1 | 1 | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 65% | 70% | 65% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 25% | 20% | 25% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | 25% | N/A | 25% |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | ||
| C | Primary entrance spacing (max.) | N/A | 50’ | 50’ | 50’ |
Table 10-2-3.2.8 Mixed-Use Building Type Standards (see Figure 10-2-3.2.13, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 10’ / 20’ | 0’ / 5’ | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 70% / 70% | 80% / 80% | 80% / 80% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 0’ | 0’ | 10’ |
| D | Interior Lot Side Setback (min. ft.) | N/A | 0’ | 0’ | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | N/A | 10' / 10’ | 0’ / 10' | 0' / 10’ |
| F | Building Coverage (max. %) | N/A | 75% | 90% | 90% |
| G | Public Amenity / Open Space and Tree Canopy Coverage (min. %) | N/A | 25% | 0% | 10% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | 2 | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 4' / 55' | 3 / 45’ | 4 / 55' |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | 65% | N/A | 80% |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | 2 | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 15' | 15' | 15' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 150’ | 150’ | 150’ |
| B | Blank Wall (max. ft.) | N/A | 20’ | 20’ | 20’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade width before articulation is required (refer to Table 10-1-3.1.A for technique options) | N/A | 25’ | 25’ | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | 2 | 2 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques required | N/A | 1 | 1 | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 65% | 70% | 65% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 25% | 20% | 25% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | 25% | N/A | 25% |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | ||
| C | Primary entrance spacing (max.) | N/A | 50’ | 50’ | 50’ |
Table 10-2-3.2.8 Mixed-Use Building Type Standards (see Figure 10-2-3.2.13, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 10’ / 20’ | 0’ / 5’ | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 70% / 70% | 80% / 80% | 80% / 80% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 0’ | 0’ | 10’ |
| D | Interior Lot Side Setback (min. ft.) | N/A | 0’ | 0’ | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | N/A | 10' / 10’ | 0’ / 10' | 0' / 10’ |
| F | Building Coverage (max. %) | N/A | 75% | 90% | 90% |
| G | Public Amenity / Open Space and Tree Canopy Coverage (min. %) | N/A | 25% | 0% | 10% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | 2 | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 4' / 55' | 3 / 45’ | 4 / 55' |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | 65% | N/A | 80% |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | 2 | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 15' | 15' | 15' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 150’ | 150’ | 150’ |
| B | Blank Wall (max. ft.) | N/A | 20’ | 20’ | 20’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade width before articulation is required (refer to Table 10-1-3.1.A for technique options) | N/A | 25’ | 25’ | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | 2 | 2 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques required | N/A | 1 | 1 | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 65% | 70% | 65% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 25% | 20% | 25% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | 25% | N/A | 25% |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | ||
| C | Primary entrance spacing (max.) | N/A | 50’ | 50’ | 50’ |
Effective on: 1/1/1901
Figure 10-2-3.2.14 Commercial Building Type | |||||
|---|---|---|---|---|---|
![]() | |||||
![]() | Primary entrance identified by raised parapet entry type and small plaza. | ![]() | Variation in roofline provides interest and reduces perceived scale | ![]() | Display windows face onto the public way |
| THE SAMPLE IMAGES BELOW ARE SHOWN ONLY FOR ILLUSTRATIVE PURPOSES AND ARE NOT MEANT TO PRESCRIBE THAT THESE FORMS MUST BE USED. | ||
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
Figure 10-2-3.2.15 Commercial Building Type (see Table 10-2-3.2.9, below) | |
|---|---|
![]() | ![]() |
| Building Placement and Building Coverage | Building Height and Upper Story Stepbacks |
![]() | ![]() |
| Building Activation | Building Form and Orientation |
Table 10-2-3.2.9 Commercial Building Type Standards (see Figure 10-2-3.2.15, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 10’ / 20’ | 0’ / 10’ | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 70% / 70% | 90% / 90% | 70% / 70% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 0’ | 0’ | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | 0’ | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | N/A | 10’ / 10' | 0’ / 10' | 0' / 10’ |
| F | Building Coverage (max. %) | N/A | 75% | 90% | 90% |
| G | Open Space and Tree Canopy Coverage (min. %) | N/A | 25% | 0% | 10% |
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | 2 | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | 3 / 45’ | 3 / 45 |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | 80% |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | 2 | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 15' | 15' | 15' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 180’ | 180’ | 180’ |
| B | Blank Wall (max. ft.) | N/A | 15’ | 15’ | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | 25’ | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | 3 | 3 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | 1 | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 40% | 60% | 40% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 20% | 20% | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) as percentage of building in plan view | N/A | 25% | N/A | 25% |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | ||
| C | Primary entrance spacing (max.) | N/A | 75’ | 75’ | 75’ |
Table 10-2-3.2.9 Commercial Building Type Standards (see Figure 10-2-3.2.15, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 10’ / 20’ | 0’ / 10’ | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 70% / 70% | 90% / 90% | 70% / 70% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 0’ | 0’ | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | 0’ | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | N/A | 10’ / 10' | 0’ / 10' | 0' / 10’ |
| F | Building Coverage (max. %) | N/A | 75% | 90% | 90% |
| G | Open Space and Tree Canopy Coverage (min. %) | N/A | 25% | 0% | 10% |
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | 2 | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | 3 / 45’ | 3 / 45 |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | 80% |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | 2 | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 15' | 15' | 15' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 180’ | 180’ | 180’ |
| B | Blank Wall (max. ft.) | N/A | 15’ | 15’ | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | 25’ | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | 3 | 3 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | 1 | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 40% | 60% | 40% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 20% | 20% | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) as percentage of building in plan view | N/A | 25% | N/A | 25% |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | ||
| C | Primary entrance spacing (max.) | N/A | 75’ | 75’ | 75’ |
Table 10-2-3.2.9 Commercial Building Type Standards (see Figure 10-2-3.2.15, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 10’ / 20’ | 0’ / 10’ | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 70% / 70% | 90% / 90% | 70% / 70% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 0’ | 0’ | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | 0’ | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | N/A | 10’ / 10' | 0’ / 10' | 0' / 10’ |
| F | Building Coverage (max. %) | N/A | 75% | 90% | 90% |
| G | Open Space and Tree Canopy Coverage (min. %) | N/A | 25% | 0% | 10% |
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | 2 | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | 3 / 45’ | 3 / 45 |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | 80% |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | 2 | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 15' | 15' | 15' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 180’ | 180’ | 180’ |
| B | Blank Wall (max. ft.) | N/A | 15’ | 15’ | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | 25’ | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | 3 | 3 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | 1 | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 40% | 60% | 40% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 20% | 20% | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) as percentage of building in plan view | N/A | 25% | N/A | 25% |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | ||
| C | Primary entrance spacing (max.) | N/A | 75’ | 75’ | 75’ |
Table 10-2-3.2.9 Commercial Building Type Standards (see Figure 10-2-3.2.15, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 10’ / 20’ | 0’ / 10’ | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 70% / 70% | 90% / 90% | 70% / 70% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 0’ | 0’ | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | 0’ | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | N/A | 10’ / 10' | 0’ / 10' | 0' / 10’ |
| F | Building Coverage (max. %) | N/A | 75% | 90% | 90% |
| G | Open Space and Tree Canopy Coverage (min. %) | N/A | 25% | 0% | 10% |
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | 2 | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | 3 / 45’ | 3 / 45 |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | 80% |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | 2 | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 15' | 15' | 15' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 180’ | 180’ | 180’ |
| B | Blank Wall (max. ft.) | N/A | 15’ | 15’ | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | 25’ | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | 3 | 3 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | 1 | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 40% | 60% | 40% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 20% | 20% | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) as percentage of building in plan view | N/A | 25% | N/A | 25% |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | ||
| C | Primary entrance spacing (max.) | N/A | 75’ | 75’ | 75’ |
Effective on: 1/1/1901
Figure 10-2-3.2.16 Office-Institutional Building Type | |||||
|---|---|---|---|---|---|
![]() | |||||
![]() | Primary entrance connects to a public walkway. | ![]() | Composition has a base, middle, and a cap with articulated walls and varied massing. | ![]() | A high degree of transparency activates the street level façade. |
| THE SAMPLE IMAGES BELOW ARE SHOWN ONLY FOR ILLUSTRATIVE PURPOSES AND ARE NOT MEANT TO PRESCRIBE THAT THESE FORMS MUST BE USED. | ||
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
Figure 10-2-3.2.17 Office - Institutional Building Type (see Table 10-2-3.2.10, below) | |
|---|---|
![]() | ![]() |
| Building Placement and Building Coverage | Building Height and Upper Story Stepbacks |
![]() |
![]() |
| Building Activation | Building Form and Orientation |
Table 10-2-3.2.10 Office - Institutional Building Type Standards (see Figure 10-2-3.2.17, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 5’ / 20’ | 0’ / 10’ | 0’ / 20’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 90% / 70% | 90% / 90% | 90% / 90% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 10’ | 10’ | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | 0’ | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | N/A | 10’ / 10' | 0’ / 10' | 0' / 10’ |
| F | Building Coverage (max. %) | N/A | 70% | 90% | 80% |
| G | Outdoor Space and Tree Canopy Coverage (min. %) | N/A | 30% | 0% | 20% |
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | 2 | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | 3 / 45' | 4 / 55'* |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | 80% |
| D | Maximum number of stories within 20 ft. of a sensitive edge | N/A | 2 | 2 | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 12' | 12' | 12' |
| * A maximum of three stories / 45’ stories is permitted in the DMU district. | |||||
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 150’ | 150’ | 100’ |
| B | Blank Wall (max. ft.) | N/A | 15’ | 15’ | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | 25’ | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | 2 | 3 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | 1 | 2 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 30% | 60% | 30% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 20% | 20% | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | 5% | N/A | N/A |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | N/A | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | ||
| C | Primary entrance spacing (max.) | N/A | 75’ | 75’ | 75’ |
Table 10-2-3.2.10 Office - Institutional Building Type Standards (see Figure 10-2-3.2.17, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 5’ / 20’ | 0’ / 10’ | 0’ / 20’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 90% / 70% | 90% / 90% | 90% / 90% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 10’ | 10’ | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | 0’ | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | N/A | 10’ / 10' | 0’ / 10' | 0' / 10’ |
| F | Building Coverage (max. %) | N/A | 70% | 90% | 80% |
| G | Outdoor Space and Tree Canopy Coverage (min. %) | N/A | 30% | 0% | 20% |
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | 2 | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | 3 / 45' | 4 / 55'* |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | 80% |
| D | Maximum number of stories within 20 ft. of a sensitive edge | N/A | 2 | 2 | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 12' | 12' | 12' |
| * A maximum of three stories / 45’ stories is permitted in the DMU district. | |||||
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 150’ | 150’ | 100’ |
| B | Blank Wall (max. ft.) | N/A | 15’ | 15’ | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | 25’ | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | 2 | 3 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | 1 | 2 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 30% | 60% | 30% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 20% | 20% | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | 5% | N/A | N/A |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | N/A | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | ||
| C | Primary entrance spacing (max.) | N/A | 75’ | 75’ | 75’ |
Table 10-2-3.2.10 Office - Institutional Building Type Standards (see Figure 10-2-3.2.17, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 5’ / 20’ | 0’ / 10’ | 0’ / 20’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 90% / 70% | 90% / 90% | 90% / 90% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 10’ | 10’ | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | 0’ | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | N/A | 10’ / 10' | 0’ / 10' | 0' / 10’ |
| F | Building Coverage (max. %) | N/A | 70% | 90% | 80% |
| G | Outdoor Space and Tree Canopy Coverage (min. %) | N/A | 30% | 0% | 20% |
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | 2 | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | 3 / 45' | 4 / 55'* |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | 80% |
| D | Maximum number of stories within 20 ft. of a sensitive edge | N/A | 2 | 2 | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 12' | 12' | 12' |
| * A maximum of three stories / 45’ stories is permitted in the DMU district. | |||||
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 150’ | 150’ | 100’ |
| B | Blank Wall (max. ft.) | N/A | 15’ | 15’ | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | 25’ | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | 2 | 3 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | 1 | 2 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 30% | 60% | 30% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 20% | 20% | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | 5% | N/A | N/A |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | N/A | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | ||
| C | Primary entrance spacing (max.) | N/A | 75’ | 75’ | 75’ |
Table 10-2-3.2.10 Office - Institutional Building Type Standards (see Figure 10-2-3.2.17, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 5’ / 20’ | 0’ / 10’ | 0’ / 20’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 90% / 70% | 90% / 90% | 90% / 90% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 10’ | 10’ | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | 0’ | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | N/A | 10’ / 10' | 0’ / 10' | 0' / 10’ |
| F | Building Coverage (max. %) | N/A | 70% | 90% | 80% |
| G | Outdoor Space and Tree Canopy Coverage (min. %) | N/A | 30% | 0% | 20% |
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | 2 | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | 3 / 45' | 4 / 55'* |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | 80% |
| D | Maximum number of stories within 20 ft. of a sensitive edge | N/A | 2 | 2 | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 12' | 12' | 12' |
| * A maximum of three stories / 45’ stories is permitted in the DMU district. | |||||
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 150’ | 150’ | 100’ |
| B | Blank Wall (max. ft.) | N/A | 15’ | 15’ | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | 25’ | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | 2 | 3 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | 1 | 2 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 30% | 60% | 30% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 20% | 20% | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | 5% | N/A | N/A |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | N/A | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | ||
| C | Primary entrance spacing (max.) | N/A | 75’ | 75’ | 75’ |
Effective on: 1/1/1901
Figure 10-2-3.2.18 Parking Structure Building Type | |||||
|---|---|---|---|---|---|
![]() | |||||
![]() | Activated street level “wrap”. | ![]() | Architectural screening of parking levels. | ![]() | Varied massing and articulation. |
| THE SAMPLE IMAGES BELOW ARE SHOWN ONLY FOR ILLUSTRATIVE PURPOSES AND ARE NOT MEANT TO PRESCRIBE THAT THESE FORMS MUST BE USED. | |||
![]() | ![]() | ![]() | |
![]() | ![]() | ||
Figure 10-2-3.2.19 Parking Structure Building Type (see Table 10-2-3.2.11, below) | |
|---|---|
![]() | ![]() |
| Building Placement and Building Coverage | Building Height and Upper Story Stepbacks |
![]() | ![]() |
| Building Activation | Building Form and Orientation |
Table 10-2-3.2.11 Parking Structure Building Type Standards (see Figure 10-2-3.2.19, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 20’ / 30’ | 20’ / 30’ | 20’ / 30’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 90% / 70% | 90% / 90% | 90% / 90% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 10’ | 1’ | 15’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | 0’ | 10’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | N/A | 15’ / 24' | 0’ / 24' | 10’ / 24' |
| F | Building Coverage (max. %) | N/A | 75% | 90% | 90% |
| G | Open Space and Tree Canopy Coverage (min. %) | N/A | 25% | 0% | 10% |
| Building Height and Upper Story Stepbacks (For building wrap) | |||||
| A | Maximum number of stories/feet of a “wrap” within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 / 30' | 2 / 30' | 2 / 30' |
| B | Maximum number of stories/feet of a “wrap” | N/A | 3 / 45' | 3 / 45' | 3 / 45' |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories/feet of a “wrap” within 10 ft. of a sensitive edge | N/A | 2 / 30' | 2 / 30' | 2 / 30' |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) of a “wrap” | N/A | 16' | 16' | 16' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | N/A | 50’ | 50’ | 50’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length of “wrap” before articulation | N/A | 50’ | 50’ | 50’ |
| D | Minimum number of articulation techniques required for “wrap” (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | 2 | 2 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques for “wrap” | N/A | 1 | 1 | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) for “wrap” | N/A | 50% | 50% | 50% |
| G | Façade glazed: % upper floor(s) wall area (min.) for “wrap” | N/A | 30% | 30% | 30% |
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | N/A | N/A | N/A |
| Building Entry | |||||
| A | Primary entrance orientation for “wrap” | N/A | Directly facing the street | ||
| B | Primary entrance spacing (max.) for “wrap” (not including vehicle entries) | N/A | 50’ | 50’ | 50’ |
Table 10-2-3.2.11 Parking Structure Building Type Standards (see Figure 10-2-3.2.19, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 20’ / 30’ | 20’ / 30’ | 20’ / 30’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 90% / 70% | 90% / 90% | 90% / 90% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 10’ | 1’ | 15’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | 0’ | 10’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | N/A | 15’ / 24' | 0’ / 24' | 10’ / 24' |
| F | Building Coverage (max. %) | N/A | 75% | 90% | 90% |
| G | Open Space and Tree Canopy Coverage (min. %) | N/A | 25% | 0% | 10% |
| Building Height and Upper Story Stepbacks (For building wrap) | |||||
| A | Maximum number of stories/feet of a “wrap” within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 / 30' | 2 / 30' | 2 / 30' |
| B | Maximum number of stories/feet of a “wrap” | N/A | 3 / 45' | 3 / 45' | 3 / 45' |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories/feet of a “wrap” within 10 ft. of a sensitive edge | N/A | 2 / 30' | 2 / 30' | 2 / 30' |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) of a “wrap” | N/A | 16' | 16' | 16' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | N/A | 50’ | 50’ | 50’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length of “wrap” before articulation | N/A | 50’ | 50’ | 50’ |
| D | Minimum number of articulation techniques required for “wrap” (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | 2 | 2 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques for “wrap” | N/A | 1 | 1 | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) for “wrap” | N/A | 50% | 50% | 50% |
| G | Façade glazed: % upper floor(s) wall area (min.) for “wrap” | N/A | 30% | 30% | 30% |
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | N/A | N/A | N/A |
| Building Entry | |||||
| A | Primary entrance orientation for “wrap” | N/A | Directly facing the street | ||
| B | Primary entrance spacing (max.) for “wrap” (not including vehicle entries) | N/A | 50’ | 50’ | 50’ |
Table 10-2-3.2.11 Parking Structure Building Type Standards (see Figure 10-2-3.2.19, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 20’ / 30’ | 20’ / 30’ | 20’ / 30’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 90% / 70% | 90% / 90% | 90% / 90% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 10’ | 1’ | 15’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | 0’ | 10’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | N/A | 15’ / 24' | 0’ / 24' | 10’ / 24' |
| F | Building Coverage (max. %) | N/A | 75% | 90% | 90% |
| G | Open Space and Tree Canopy Coverage (min. %) | N/A | 25% | 0% | 10% |
| Building Height and Upper Story Stepbacks (For building wrap) | |||||
| A | Maximum number of stories/feet of a “wrap” within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 / 30' | 2 / 30' | 2 / 30' |
| B | Maximum number of stories/feet of a “wrap” | N/A | 3 / 45' | 3 / 45' | 3 / 45' |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories/feet of a “wrap” within 10 ft. of a sensitive edge | N/A | 2 / 30' | 2 / 30' | 2 / 30' |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) of a “wrap” | N/A | 16' | 16' | 16' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | N/A | 50’ | 50’ | 50’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length of “wrap” before articulation | N/A | 50’ | 50’ | 50’ |
| D | Minimum number of articulation techniques required for “wrap” (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | 2 | 2 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques for “wrap” | N/A | 1 | 1 | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) for “wrap” | N/A | 50% | 50% | 50% |
| G | Façade glazed: % upper floor(s) wall area (min.) for “wrap” | N/A | 30% | 30% | 30% |
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | N/A | N/A | N/A |
| Building Entry | |||||
| A | Primary entrance orientation for “wrap” | N/A | Directly facing the street | ||
| B | Primary entrance spacing (max.) for “wrap” (not including vehicle entries) | N/A | 50’ | 50’ | 50’ |
Table 10-2-3.2.11 Parking Structure Building Type Standards (see Figure 10-2-3.2.19, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 20’ / 30’ | 20’ / 30’ | 20’ / 30’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 90% / 70% | 90% / 90% | 90% / 90% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 10’ | 1’ | 15’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | 0’ | 10’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | N/A | 15’ / 24' | 0’ / 24' | 10’ / 24' |
| F | Building Coverage (max. %) | N/A | 75% | 90% | 90% |
| G | Open Space and Tree Canopy Coverage (min. %) | N/A | 25% | 0% | 10% |
| Building Height and Upper Story Stepbacks (For building wrap) | |||||
| A | Maximum number of stories/feet of a “wrap” within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 / 30' | 2 / 30' | 2 / 30' |
| B | Maximum number of stories/feet of a “wrap” | N/A | 3 / 45' | 3 / 45' | 3 / 45' |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories/feet of a “wrap” within 10 ft. of a sensitive edge | N/A | 2 / 30' | 2 / 30' | 2 / 30' |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) of a “wrap” | N/A | 16' | 16' | 16' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | N/A | 50’ | 50’ | 50’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length of “wrap” before articulation | N/A | 50’ | 50’ | 50’ |
| D | Minimum number of articulation techniques required for “wrap” (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | 2 | 2 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques for “wrap” | N/A | 1 | 1 | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) for “wrap” | N/A | 50% | 50% | 50% |
| G | Façade glazed: % upper floor(s) wall area (min.) for “wrap” | N/A | 30% | 30% | 30% |
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | N/A | N/A | N/A |
| Building Entry | |||||
| A | Primary entrance orientation for “wrap” | N/A | Directly facing the street | ||
| B | Primary entrance spacing (max.) for “wrap” (not including vehicle entries) | N/A | 50’ | 50’ | 50’ |
Effective on: 1/1/1901
Effective on: 1/1/1901
DOWNTOWN DT
| Related Provisions | ||
|---|---|---|
| Sec. 10-1-1.3 | Land Use Matrix | Permitted, specially permitted, conditional, and accessory uses permitted within the NC and CM districts |
| Sec. 10-1-1.4 | Land Use Standards | Standards that apply to land uses denoted with an "S" in Section 10-1-1.3, Land Use Matrix |
| Sec. 10-9-5.1 | Conditional Use Standards | Standards for land uses denoted as "C" in Section 10-1-1.3, Land Use Matrix |
| Sec. 10-1-2.3 | Height and Yard Exceptions | Allowable exceptions to the setbacks and heights within the NC and CM districts |
| Sec. 10-1-3.1 | General Design Standards | Standards relating to wall articulation, varied massing, blank walls, and screening |
| Sec. 10-1-3.2 | Non-Residential and Mixed-Use Design Standards | Permitted and alternative materials and CPTED review standards |
| Sec. 10-9-5.8 | Adaptive Reuse Plan | Development standards and reuse incentives for the revitalization or redevelopment of buildings |
| Sec. 10-1-3.4 | Sustainable Building Design | Incentives for the use of sustainable design and development practices |
| Sec. 10-1-3.7 | Vehicle Mobility | Minimum required and maximum allowable parking, credits and reductions, vehicle access and parking design, landscape and screening standards, and pedestrian circulation (Subsection 10-1-3.7.B, Parking and Access in the DT Districts) |
| Sec. 10-1-3.8 | Alternative Mobility | Bicycle parking standards |
| Sec. 10-1-3.11 | Outdoor Lighting Standards | Standards for on-site exterior lighting and for certain districts, uses and site features |
| Sec. 10-9-3.10 | Development Review Summary | Descriptions of all required approval and permit processes |
| Sec. 10-12-2.1 | Definitions | Definitions of land uses and general terms |
| Base Standards | ||
| Sec. 10-1-3.6 | Greenspace Design Standards | General planting, landscape, bufferyard and tree canopy coverage requirements |
| Sec. 10-1-3.10 | Sign Standards | Signs allowed and prohibited, installation and maintenance requirements, means of measuring sign dimensions, bonuses, and standards for temporary signs |
| Related Provisions | ||
|---|---|---|
| Sec. 10-1-1.3 | Land Use Matrix | Permitted, specially permitted, conditional, and accessory uses permitted within the NC and CM districts |
| Sec. 10-1-1.4 | Land Use Standards | Standards that apply to land uses denoted with an "S" in Section 10-1-1.3, Land Use Matrix |
| Sec. 10-9-5.1 | Conditional Use Standards | Standards for land uses denoted as "C" in Section 10-1-1.3, Land Use Matrix |
| Sec. 10-1-2.3 | Height and Yard Exceptions | Allowable exceptions to the setbacks and heights within the NC and CM districts |
| Sec. 10-1-3.1 | General Design Standards | Standards relating to wall articulation, varied massing, blank walls, and screening |
| Sec. 10-1-3.2 | Non-Residential and Mixed-Use Design Standards | Permitted and alternative materials and CPTED review standards |
| Sec. 10-9-5.8 | Adaptive Reuse Plan | Development standards and reuse incentives for the revitalization or redevelopment of buildings |
| Sec. 10-1-3.4 | Sustainable Building Design | Incentives for the use of sustainable design and development practices |
| Sec. 10-1-3.7 | Vehicle Mobility | Minimum required and maximum allowable parking, credits and reductions, vehicle access and parking design, landscape and screening standards, and pedestrian circulation (Subsection 10-1-3.7.B, Parking and Access in the DT Districts) |
| Sec. 10-1-3.8 | Alternative Mobility | Bicycle parking standards |
| Sec. 10-1-3.11 | Outdoor Lighting Standards | Standards for on-site exterior lighting and for certain districts, uses and site features |
| Sec. 10-9-3.10 | Development Review Summary | Descriptions of all required approval and permit processes |
| Sec. 10-12-2.1 | Definitions | Definitions of land uses and general terms |
| Base Standards | ||
| Sec. 10-1-3.6 | Greenspace Design Standards | General planting, landscape, bufferyard and tree canopy coverage requirements |
| Sec. 10-1-3.10 | Sign Standards | Signs allowed and prohibited, installation and maintenance requirements, means of measuring sign dimensions, bonuses, and standards for temporary signs |
| Related Provisions | ||
|---|---|---|
| Sec. 10-1-1.3 | Land Use Matrix | Permitted, specially permitted, conditional, and accessory uses permitted within the NC and CM districts |
| Sec. 10-1-1.4 | Land Use Standards | Standards that apply to land uses denoted with an "S" in Section 10-1-1.3, Land Use Matrix |
| Sec. 10-9-5.1 | Conditional Use Standards | Standards for land uses denoted as "C" in Section 10-1-1.3, Land Use Matrix |
| Sec. 10-1-2.3 | Height and Yard Exceptions | Allowable exceptions to the setbacks and heights within the NC and CM districts |
| Sec. 10-1-3.1 | General Design Standards | Standards relating to wall articulation, varied massing, blank walls, and screening |
| Sec. 10-1-3.2 | Non-Residential and Mixed-Use Design Standards | Permitted and alternative materials and CPTED review standards |
| Sec. 10-9-5.8 | Adaptive Reuse Plan | Development standards and reuse incentives for the revitalization or redevelopment of buildings |
| Sec. 10-1-3.4 | Sustainable Building Design | Incentives for the use of sustainable design and development practices |
| Sec. 10-1-3.7 | Vehicle Mobility | Minimum required and maximum allowable parking, credits and reductions, vehicle access and parking design, landscape and screening standards, and pedestrian circulation (Subsection 10-1-3.7.B, Parking and Access in the DT Districts) |
| Sec. 10-1-3.8 | Alternative Mobility | Bicycle parking standards |
| Sec. 10-1-3.11 | Outdoor Lighting Standards | Standards for on-site exterior lighting and for certain districts, uses and site features |
| Sec. 10-9-3.10 | Development Review Summary | Descriptions of all required approval and permit processes |
| Sec. 10-12-2.1 | Definitions | Definitions of land uses and general terms |
| Base Standards | ||
| Sec. 10-1-3.6 | Greenspace Design Standards | General planting, landscape, bufferyard and tree canopy coverage requirements |
| Sec. 10-1-3.10 | Sign Standards | Signs allowed and prohibited, installation and maintenance requirements, means of measuring sign dimensions, bonuses, and standards for temporary signs |
| Related Provisions | ||
|---|---|---|
| Sec. 10-1-1.3 | Land Use Matrix | Permitted, specially permitted, conditional, and accessory uses permitted within the NC and CM districts |
| Sec. 10-1-1.4 | Land Use Standards | Standards that apply to land uses denoted with an "S" in Section 10-1-1.3, Land Use Matrix |
| Sec. 10-9-5.1 | Conditional Use Standards | Standards for land uses denoted as "C" in Section 10-1-1.3, Land Use Matrix |
| Sec. 10-1-2.3 | Height and Yard Exceptions | Allowable exceptions to the setbacks and heights within the NC and CM districts |
| Sec. 10-1-3.1 | General Design Standards | Standards relating to wall articulation, varied massing, blank walls, and screening |
| Sec. 10-1-3.2 | Non-Residential and Mixed-Use Design Standards | Permitted and alternative materials and CPTED review standards |
| Sec. 10-9-5.8 | Adaptive Reuse Plan | Development standards and reuse incentives for the revitalization or redevelopment of buildings |
| Sec. 10-1-3.4 | Sustainable Building Design | Incentives for the use of sustainable design and development practices |
| Sec. 10-1-3.7 | Vehicle Mobility | Minimum required and maximum allowable parking, credits and reductions, vehicle access and parking design, landscape and screening standards, and pedestrian circulation (Subsection 10-1-3.7.B, Parking and Access in the DT Districts) |
| Sec. 10-1-3.8 | Alternative Mobility | Bicycle parking standards |
| Sec. 10-1-3.11 | Outdoor Lighting Standards | Standards for on-site exterior lighting and for certain districts, uses and site features |
| Sec. 10-9-3.10 | Development Review Summary | Descriptions of all required approval and permit processes |
| Sec. 10-12-2.1 | Definitions | Definitions of land uses and general terms |
| Base Standards | ||
| Sec. 10-1-3.6 | Greenspace Design Standards | General planting, landscape, bufferyard and tree canopy coverage requirements |
| Sec. 10-1-3.10 | Sign Standards | Signs allowed and prohibited, installation and maintenance requirements, means of measuring sign dimensions, bonuses, and standards for temporary signs |
(Ord. 20, Series of 2023)
(Ord. 18, Series of 2022)
Effective on: 8/25/2022
Effective on: 10/28/2021
(Ord. 18, Series of 2022)
Effective on: 8/25/2022
Effective on: 10/28/2021
Table 10-2-3.1 Building Materials Permitted by DT District | |||||
|---|---|---|---|---|---|
| P = Primary material; S = Secondary material (less than 25% of façade area); "--" = Not permitted | |||||
| Material Type | DNR | DMU | DMS | DTA | |
| 1 Masonry | |||||
| 1a) | Modular Brick | P, S | P, S | P, S | P, S |
| 1b) | Modular Stone | P, S | P, S | S | P, S |
| 1c) | Architectural cast or precast concrete (detailed) | S | P, S | S | P, S |
| 1d) | Architectural reinforced concrete (glass fiber, fiber) | -- | P, S | -- | S |
| 1e) | Cement board siding | P, S | P, S | -- | S |
| 1f) | Terra cotta | P, S | P, S | P, S | P, S |
| 1g) | Cast stone | P, S | P, S | S | P, S |
| 1h) | An architectural concrete masonry unit | -- | S | -- | S |
| 1i) | Panelized brick or stone | S | P, S | -- | S |
| 2 Metal | |||||
| 2a) | Metal panels | -- | S | S | S |
| 2b) | Metal accents | S | S | S | S |
| 3 Siding | |||||
| 3a) | Horizontal lap (wood, cement board) | P, S | S | S* | P, S |
| 3b) | Shingles (wood, cement board) | P, S | S | -- | P, S |
| Vertical board and batten (wood, cement board) | P, S | -- | -- | P, S | |
| 4 Stucco | |||||
| 4a) | Authentic | P, S | P, S | P, S | P, S |
| 4b) | Synthetic (scored) | S | P, S | -- | S |
| 4c) | Synthetic (not scored) | S | -- | -- | S |
| 5 Glass | |||||
| 5a) | Curtain wall | -- | S | -- | S |
| 5b) | Glass Accent | S | S | S | S |
| TABLE NOTES: *This is only allowed on upper stories that are stepped back from the building front. | |||||
Table 10-2-3.1 Building Materials Permitted by DT District | |||||
|---|---|---|---|---|---|
| P = Primary material; S = Secondary material (less than 25% of façade area); "--" = Not permitted | |||||
| Material Type | DNR | DMU | DMS | DTA | |
| 1 Masonry | |||||
| 1a) | Modular Brick | P, S | P, S | P, S | P, S |
| 1b) | Modular Stone | P, S | P, S | S | P, S |
| 1c) | Architectural cast or precast concrete (detailed) | S | P, S | S | P, S |
| 1d) | Architectural reinforced concrete (glass fiber, fiber) | -- | P, S | -- | S |
| 1e) | Cement board siding | P, S | P, S | -- | S |
| 1f) | Terra cotta | P, S | P, S | P, S | P, S |
| 1g) | Cast stone | P, S | P, S | S | P, S |
| 1h) | An architectural concrete masonry unit | -- | S | -- | S |
| 1i) | Panelized brick or stone | S | P, S | -- | S |
| 2 Metal | |||||
| 2a) | Metal panels | -- | S | S | S |
| 2b) | Metal accents | S | S | S | S |
| 3 Siding | |||||
| 3a) | Horizontal lap (wood, cement board) | P, S | S | S* | P, S |
| 3b) | Shingles (wood, cement board) | P, S | S | -- | P, S |
| Vertical board and batten (wood, cement board) | P, S | -- | -- | P, S | |
| 4 Stucco | |||||
| 4a) | Authentic | P, S | P, S | P, S | P, S |
| 4b) | Synthetic (scored) | S | P, S | -- | S |
| 4c) | Synthetic (not scored) | S | -- | -- | S |
| 5 Glass | |||||
| 5a) | Curtain wall | -- | S | -- | S |
| 5b) | Glass Accent | S | S | S | S |
| TABLE NOTES: *This is only allowed on upper stories that are stepped back from the building front. | |||||
Table 10-2-3.1 Building Materials Permitted by DT District | |||||
|---|---|---|---|---|---|
| P = Primary material; S = Secondary material (less than 25% of façade area); "--" = Not permitted | |||||
| Material Type | DNR | DMU | DMS | DTA | |
| 1 Masonry | |||||
| 1a) | Modular Brick | P, S | P, S | P, S | P, S |
| 1b) | Modular Stone | P, S | P, S | S | P, S |
| 1c) | Architectural cast or precast concrete (detailed) | S | P, S | S | P, S |
| 1d) | Architectural reinforced concrete (glass fiber, fiber) | -- | P, S | -- | S |
| 1e) | Cement board siding | P, S | P, S | -- | S |
| 1f) | Terra cotta | P, S | P, S | P, S | P, S |
| 1g) | Cast stone | P, S | P, S | S | P, S |
| 1h) | An architectural concrete masonry unit | -- | S | -- | S |
| 1i) | Panelized brick or stone | S | P, S | -- | S |
| 2 Metal | |||||
| 2a) | Metal panels | -- | S | S | S |
| 2b) | Metal accents | S | S | S | S |
| 3 Siding | |||||
| 3a) | Horizontal lap (wood, cement board) | P, S | S | S* | P, S |
| 3b) | Shingles (wood, cement board) | P, S | S | -- | P, S |
| Vertical board and batten (wood, cement board) | P, S | -- | -- | P, S | |
| 4 Stucco | |||||
| 4a) | Authentic | P, S | P, S | P, S | P, S |
| 4b) | Synthetic (scored) | S | P, S | -- | S |
| 4c) | Synthetic (not scored) | S | -- | -- | S |
| 5 Glass | |||||
| 5a) | Curtain wall | -- | S | -- | S |
| 5b) | Glass Accent | S | S | S | S |
| TABLE NOTES: *This is only allowed on upper stories that are stepped back from the building front. | |||||
Table 10-2-3.1 Building Materials Permitted by DT District | |||||
|---|---|---|---|---|---|
| P = Primary material; S = Secondary material (less than 25% of façade area); "--" = Not permitted | |||||
| Material Type | DNR | DMU | DMS | DTA | |
| 1 Masonry | |||||
| 1a) | Modular Brick | P, S | P, S | P, S | P, S |
| 1b) | Modular Stone | P, S | P, S | S | P, S |
| 1c) | Architectural cast or precast concrete (detailed) | S | P, S | S | P, S |
| 1d) | Architectural reinforced concrete (glass fiber, fiber) | -- | P, S | -- | S |
| 1e) | Cement board siding | P, S | P, S | -- | S |
| 1f) | Terra cotta | P, S | P, S | P, S | P, S |
| 1g) | Cast stone | P, S | P, S | S | P, S |
| 1h) | An architectural concrete masonry unit | -- | S | -- | S |
| 1i) | Panelized brick or stone | S | P, S | -- | S |
| 2 Metal | |||||
| 2a) | Metal panels | -- | S | S | S |
| 2b) | Metal accents | S | S | S | S |
| 3 Siding | |||||
| 3a) | Horizontal lap (wood, cement board) | P, S | S | S* | P, S |
| 3b) | Shingles (wood, cement board) | P, S | S | -- | P, S |
| Vertical board and batten (wood, cement board) | P, S | -- | -- | P, S | |
| 4 Stucco | |||||
| 4a) | Authentic | P, S | P, S | P, S | P, S |
| 4b) | Synthetic (scored) | S | P, S | -- | S |
| 4c) | Synthetic (not scored) | S | -- | -- | S |
| 5 Glass | |||||
| 5a) | Curtain wall | -- | S | -- | S |
| 5b) | Glass Accent | S | S | S | S |
| TABLE NOTES: *This is only allowed on upper stories that are stepped back from the building front. | |||||
Effective on: 10/28/2021
Table 10-2-3.2.1 Permitted Building Types by District | ||||
|---|---|---|---|---|
| Building Type | Downtown Zoning Districts | |||
| Downtown Neighborhood Residential (DNR) | Downtown Transition Area (DTA) | Downtown Main Street (DMS) | Downtown Mixed-Use (DMU) | |
| Residential | ||||
| Apartment | -- | P | -- | P |
| Mixed-Use Building (upper floor residential units) | -- | P | P | P |
| Dwelling, Single-Family Attached / Duplex | P | P | -- | P |
| Dwelling, Single-Family Detached | P | P | -- | P |
| Multiplex (3-6 residential units) | P | P | -- | P |
| Townhouse | P | P | -- | P |
| Non-residential / Mixed-Use | ||||
| Live-Work | -- | P | -- | P |
| Mixed-Use | -- | P | P | P |
| Commercial | -- | P | P | P |
| Office-Institutional | -- | P | P | P |
| Parking Structure | -- | P | P | P |
Table 10-2-3.2.1 Permitted Building Types by District | ||||
|---|---|---|---|---|
| Building Type | Downtown Zoning Districts | |||
| Downtown Neighborhood Residential (DNR) | Downtown Transition Area (DTA) | Downtown Main Street (DMS) | Downtown Mixed-Use (DMU) | |
| Residential | ||||
| Apartment | -- | P | -- | P |
| Mixed-Use Building (upper floor residential units) | -- | P | P | P |
| Dwelling, Single-Family Attached / Duplex | P | P | -- | P |
| Dwelling, Single-Family Detached | P | P | -- | P |
| Multiplex (3-6 residential units) | P | P | -- | P |
| Townhouse | P | P | -- | P |
| Non-residential / Mixed-Use | ||||
| Live-Work | -- | P | -- | P |
| Mixed-Use | -- | P | P | P |
| Commercial | -- | P | P | P |
| Office-Institutional | -- | P | P | P |
| Parking Structure | -- | P | P | P |
Table 10-2-3.2.1 Permitted Building Types by District | ||||
|---|---|---|---|---|
| Building Type | Downtown Zoning Districts | |||
| Downtown Neighborhood Residential (DNR) | Downtown Transition Area (DTA) | Downtown Main Street (DMS) | Downtown Mixed-Use (DMU) | |
| Residential | ||||
| Apartment | -- | P | -- | P |
| Mixed-Use Building (upper floor residential units) | -- | P | P | P |
| Dwelling, Single-Family Attached / Duplex | P | P | -- | P |
| Dwelling, Single-Family Detached | P | P | -- | P |
| Multiplex (3-6 residential units) | P | P | -- | P |
| Townhouse | P | P | -- | P |
| Non-residential / Mixed-Use | ||||
| Live-Work | -- | P | -- | P |
| Mixed-Use | -- | P | P | P |
| Commercial | -- | P | P | P |
| Office-Institutional | -- | P | P | P |
| Parking Structure | -- | P | P | P |
Table 10-2-3.2.1 Permitted Building Types by District | ||||
|---|---|---|---|---|
| Building Type | Downtown Zoning Districts | |||
| Downtown Neighborhood Residential (DNR) | Downtown Transition Area (DTA) | Downtown Main Street (DMS) | Downtown Mixed-Use (DMU) | |
| Residential | ||||
| Apartment | -- | P | -- | P |
| Mixed-Use Building (upper floor residential units) | -- | P | P | P |
| Dwelling, Single-Family Attached / Duplex | P | P | -- | P |
| Dwelling, Single-Family Detached | P | P | -- | P |
| Multiplex (3-6 residential units) | P | P | -- | P |
| Townhouse | P | P | -- | P |
| Non-residential / Mixed-Use | ||||
| Live-Work | -- | P | -- | P |
| Mixed-Use | -- | P | P | P |
| Commercial | -- | P | P | P |
| Office-Institutional | -- | P | P | P |
| Parking Structure | -- | P | P | P |
Table 10-2-4.1.1 Public Open Space Standards | |
|---|---|
| Type | Standard |
Plaza![]() | General Character
Location and Size
|
Pocket Park![]() | General Character
Location and Size
|
Common Green![]() | General Character
Location and Size
|
Paseo![]() | General Character
Location and Size
|
Rooftop Garden![]() | General Character
Location and Size
|
Parklet![]() | General Character
Location and Size
|
Table 10-2-4.1.1 Public Open Space Standards | |
|---|---|
| Type | Standard |
Plaza![]() | General Character
Location and Size
|
Pocket Park![]() | General Character
Location and Size
|
Common Green![]() | General Character
Location and Size
|
Paseo![]() | General Character
Location and Size
|
Rooftop Garden![]() | General Character
Location and Size
|
Parklet![]() | General Character
Location and Size
|
Table 10-2-4.1.1 Public Open Space Standards | |
|---|---|
| Type | Standard |
Plaza![]() | General Character
Location and Size
|
Pocket Park![]() | General Character
Location and Size
|
Common Green![]() | General Character
Location and Size
|
Paseo![]() | General Character
Location and Size
|
Rooftop Garden![]() | General Character
Location and Size
|
Parklet![]() | General Character
Location and Size
|
Table 10-2-4.1.1 Public Open Space Standards | |
|---|---|
| Type | Standard |
Plaza![]() | General Character
Location and Size
|
Pocket Park![]() | General Character
Location and Size
|
Common Green![]() | General Character
Location and Size
|
Paseo![]() | General Character
Location and Size
|
Rooftop Garden![]() | General Character
Location and Size
|
Parklet![]() | General Character
Location and Size
|
Table 10-2-4.1.2 Minimum Size of Trees or Shrubs at Installation | ||
|---|---|---|
Type of Plant | Distance from Public Right-of-Way | |
| 10 feet or less, or in tree lawns or medians | More than 10 feet | |
| Shade Tree (>30’ in mature height) | 2-inch caliper | 2-inch caliper |
| Ornamental Tree (<25’ in mature height) | 1.5-inch caliper | 1.5-inch caliper |
| Evergreen Tree | 8-feet in height | 6-feet in height |
| Shrub | 5-gallon container | 5-gallon container |
Table 10-2-4.1.2 Minimum Size of Trees or Shrubs at Installation | ||
|---|---|---|
Type of Plant | Distance from Public Right-of-Way | |
| 10 feet or less, or in tree lawns or medians | More than 10 feet | |
| Shade Tree (>30’ in mature height) | 2-inch caliper | 2-inch caliper |
| Ornamental Tree (<25’ in mature height) | 1.5-inch caliper | 1.5-inch caliper |
| Evergreen Tree | 8-feet in height | 6-feet in height |
| Shrub | 5-gallon container | 5-gallon container |
Table 10-2-4.1.2 Minimum Size of Trees or Shrubs at Installation | ||
|---|---|---|
Type of Plant | Distance from Public Right-of-Way | |
| 10 feet or less, or in tree lawns or medians | More than 10 feet | |
| Shade Tree (>30’ in mature height) | 2-inch caliper | 2-inch caliper |
| Ornamental Tree (<25’ in mature height) | 1.5-inch caliper | 1.5-inch caliper |
| Evergreen Tree | 8-feet in height | 6-feet in height |
| Shrub | 5-gallon container | 5-gallon container |
Table 10-2-4.1.2 Minimum Size of Trees or Shrubs at Installation | ||
|---|---|---|
Type of Plant | Distance from Public Right-of-Way | |
| 10 feet or less, or in tree lawns or medians | More than 10 feet | |
| Shade Tree (>30’ in mature height) | 2-inch caliper | 2-inch caliper |
| Ornamental Tree (<25’ in mature height) | 1.5-inch caliper | 1.5-inch caliper |
| Evergreen Tree | 8-feet in height | 6-feet in height |
| Shrub | 5-gallon container | 5-gallon container |
Effective on: 10/28/2021
| Figure 10-2-4.2.1 Bufferyard Illustration |
|---|
![]() |
Figure 10-2-4.2.2 Average Bufferyard Width |
|---|
![]() |
Table 10-2-4.2.1 Building Type Bufferyard Requirements | ||||
|---|---|---|---|---|
| District | SFD, SFA | MP, TH | LW, MU, APT | COM, OFF, INS, PS |
| SFD, SFA | -- | -- | R | R |
| MP, TH, | -- | -- | -- | R |
| LW, MU, APT | R | -- | -- | -- |
| COM, OFF, INS, PS | R | R | -- | -- |
Table Notes: SFD = Single-family detached; SFA = Single-family attached/Duplex; MP = Multiplex; TH = Townhouse; APT = Apartment; LW = Live-Work; MU = Mixed-Use; COM = Commercial; OFF = Office; INS = Institutional; PS = Parking Structure R = Bufferyard required | ||||
Table 10-2-4.2.1 Building Type Bufferyard Requirements | ||||
|---|---|---|---|---|
| District | SFD, SFA | MP, TH | LW, MU, APT | COM, OFF, INS, PS |
| SFD, SFA | -- | -- | R | R |
| MP, TH, | -- | -- | -- | R |
| LW, MU, APT | R | -- | -- | -- |
| COM, OFF, INS, PS | R | R | -- | -- |
Table Notes: SFD = Single-family detached; SFA = Single-family attached/Duplex; MP = Multiplex; TH = Townhouse; APT = Apartment; LW = Live-Work; MU = Mixed-Use; COM = Commercial; OFF = Office; INS = Institutional; PS = Parking Structure R = Bufferyard required | ||||
Table 10-2-4.2.1 Building Type Bufferyard Requirements | ||||
|---|---|---|---|---|
| District | SFD, SFA | MP, TH | LW, MU, APT | COM, OFF, INS, PS |
| SFD, SFA | -- | -- | R | R |
| MP, TH, | -- | -- | -- | R |
| LW, MU, APT | R | -- | -- | -- |
| COM, OFF, INS, PS | R | R | -- | -- |
Table Notes: SFD = Single-family detached; SFA = Single-family attached/Duplex; MP = Multiplex; TH = Townhouse; APT = Apartment; LW = Live-Work; MU = Mixed-Use; COM = Commercial; OFF = Office; INS = Institutional; PS = Parking Structure R = Bufferyard required | ||||
Table 10-2-4.2.1 Building Type Bufferyard Requirements | ||||
|---|---|---|---|---|
| District | SFD, SFA | MP, TH | LW, MU, APT | COM, OFF, INS, PS |
| SFD, SFA | -- | -- | R | R |
| MP, TH, | -- | -- | -- | R |
| LW, MU, APT | R | -- | -- | -- |
| COM, OFF, INS, PS | R | R | -- | -- |
Table Notes: SFD = Single-family detached; SFA = Single-family attached/Duplex; MP = Multiplex; TH = Townhouse; APT = Apartment; LW = Live-Work; MU = Mixed-Use; COM = Commercial; OFF = Office; INS = Institutional; PS = Parking Structure R = Bufferyard required | ||||
Effective on: 10/28/2021
Table 10-2-5.1.1 Sign Types by District | |||||
|---|---|---|---|---|---|
| DNR | DTA | DMS | DMU | Standards Reference | |
| Attached Signs | |||||
| Arcade | P | P | P | P | -- |
| Awning | -- | P | P | P | C.7 |
| Marquee | -- | -- | P1 | P1 | -- |
| Mural | -- | -- | P | P | C.8 |
| Projecting | -- | P | P | P | C.9 |
| Wall | P | P | P | P | C.10 |
| Window | P | P | P | P | C.11 |
| Detached Signs | |||||
| Monument | P | P | -- | P | -- |
| Pole | -- | P | -- | P | C.12 |
Table Notes:
| |||||
Table 10-2-5.1.1 Sign Types by District | |||||
|---|---|---|---|---|---|
| DNR | DTA | DMS | DMU | Standards Reference | |
| Attached Signs | |||||
| Arcade | P | P | P | P | -- |
| Awning | -- | P | P | P | C.7 |
| Marquee | -- | -- | P1 | P1 | -- |
| Mural | -- | -- | P | P | C.8 |
| Projecting | -- | P | P | P | C.9 |
| Wall | P | P | P | P | C.10 |
| Window | P | P | P | P | C.11 |
| Detached Signs | |||||
| Monument | P | P | -- | P | -- |
| Pole | -- | P | -- | P | C.12 |
Table Notes:
| |||||
Table 10-2-5.1.1 Sign Types by District | |||||
|---|---|---|---|---|---|
| DNR | DTA | DMS | DMU | Standards Reference | |
| Attached Signs | |||||
| Arcade | P | P | P | P | -- |
| Awning | -- | P | P | P | C.7 |
| Marquee | -- | -- | P1 | P1 | -- |
| Mural | -- | -- | P | P | C.8 |
| Projecting | -- | P | P | P | C.9 |
| Wall | P | P | P | P | C.10 |
| Window | P | P | P | P | C.11 |
| Detached Signs | |||||
| Monument | P | P | -- | P | -- |
| Pole | -- | P | -- | P | C.12 |
Table Notes:
| |||||
Table 10-2-5.1.1 Sign Types by District | |||||
|---|---|---|---|---|---|
| DNR | DTA | DMS | DMU | Standards Reference | |
| Attached Signs | |||||
| Arcade | P | P | P | P | -- |
| Awning | -- | P | P | P | C.7 |
| Marquee | -- | -- | P1 | P1 | -- |
| Mural | -- | -- | P | P | C.8 |
| Projecting | -- | P | P | P | C.9 |
| Wall | P | P | P | P | C.10 |
| Window | P | P | P | P | C.11 |
| Detached Signs | |||||
| Monument | P | P | -- | P | -- |
| Pole | -- | P | -- | P | C.12 |
Table Notes:
| |||||
Table 10-2-5.1.2 Attached Permanent Sign Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| DNR | DTA | DMS | DMU | |||||
| Arcade Sign | ||||||||
| Number Allowed | -- | -- | 1 per public entrance under arcade | |||||
| Maximum Area | -- | -- | 6 sq. ft. | |||||
| Minimum Clearance above Sidewalk | -- | -- | 8 ft. | |||||
| Illumination | -- | -- | External downlighting or halo | |||||
| Changeable Copy | -- | -- | Not permitted | |||||
| Awning Sign | ||||||||
| Number Allowed | -- | One per building façade or one per storefront for a mixed-use or multi-tenant building | ||||||
| Maximum Area | -- | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear foot of façade width, whichever is greatest1 | ||||||
| Minimum Vertical Clearance/ Maximum Height Above Grade | -- | 8 ft./ No higher than top of ground floor | ||||||
| Illumination | -- | External downlighting | ||||||
| Changeable Copy | -- | Not permitted | ||||||
| Marquee Signs | ||||||||
| Number Allowed | -- | -- | 1 per building front façade | |||||
| Maximum Area | -- | -- | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear foot of building front width, whichever is greatest1 | |||||
| Min./ Max. Clearance Above Grade | -- | -- | 12 ft./25 ft. | |||||
| Maximum Distance from Building Façade | -- | -- | 48 inches5 | |||||
| Illumination | -- | -- | Internal or halo | |||||
| Changeable Copy | -- | -- | Permitted | |||||
| Mural Sign | ||||||||
| Number Allowed | -- | -- | 1 per building façade | |||||
| Maximum Area | -- | -- | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear foot of building front width, whichever is greatest1 | |||||
| Maximum Height | -- | -- | Above ground floor but no higher than the roofline | |||||
| Illumination | -- | -- | External downlighting | |||||
| Changeable Copy | -- | -- | Not permitted | |||||
| Projecting Signs | ||||||||
| Number Allowed | -- | 1 per tenant per building frontage and 1 per tenant in the alley of the building, if applicable | ||||||
| Maximum Area | -- | 12 sq. ft. per face or 24 sq. ft. per sign | ||||||
| Min./Max. Clearance Above Grade | -- | 8 ft./No higher than the ground floor | ||||||
| Illumination | -- | Internal, halo, or downlight | ||||||
| Changeable Copy | -- | Not Permitted | ||||||
| Wall Signs4 | ||||||||
| Number Allowed | 1 per tenant per building frontage | |||||||
| Maximum Area/Sign | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of façade width occupied by an individual business, whichever is greatest1 | |||||||
| Max. Clearance Above Grade | No higher than roof or parapet line2 | |||||||
| Maximum Projection from Wall | 12 inches | |||||||
| Illumination | External downlighting, internal, or halo | |||||||
| Changeable Copy | Not Permitted | |||||||
| Other Standards | Wall signs professionally painted directly onto a wall are deemed mural signs | |||||||
| Window Signs | ||||||||
| Number Allowed | 1 per tenant per building frontage | |||||||
| Maximum Area | 10% of combined area of all windows | |||||||
| Max. Clearance Above Grade | No higher than roof or parapet line | |||||||
| Illumination | Internal with nighttime NITs level not to exceed 500 nits | |||||||
| Changeable Copy | Not permitted | Permitted3 | ||||||
Table Notes:
"--" = Sign type is not permitted | ||||||||
Table 10-2-5.1.2 Attached Permanent Sign Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| DNR | DTA | DMS | DMU | |||||
| Arcade Sign | ||||||||
| Number Allowed | -- | -- | 1 per public entrance under arcade | |||||
| Maximum Area | -- | -- | 6 sq. ft. | |||||
| Minimum Clearance above Sidewalk | -- | -- | 8 ft. | |||||
| Illumination | -- | -- | External downlighting or halo | |||||
| Changeable Copy | -- | -- | Not permitted | |||||
| Awning Sign | ||||||||
| Number Allowed | -- | One per building façade or one per storefront for a mixed-use or multi-tenant building | ||||||
| Maximum Area | -- | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear foot of façade width, whichever is greatest1 | ||||||
| Minimum Vertical Clearance/ Maximum Height Above Grade | -- | 8 ft./ No higher than top of ground floor | ||||||
| Illumination | -- | External downlighting | ||||||
| Changeable Copy | -- | Not permitted | ||||||
| Marquee Signs | ||||||||
| Number Allowed | -- | -- | 1 per building front façade | |||||
| Maximum Area | -- | -- | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear foot of building front width, whichever is greatest1 | |||||
| Min./ Max. Clearance Above Grade | -- | -- | 12 ft./25 ft. | |||||
| Maximum Distance from Building Façade | -- | -- | 48 inches5 | |||||
| Illumination | -- | -- | Internal or halo | |||||
| Changeable Copy | -- | -- | Permitted | |||||
| Mural Sign | ||||||||
| Number Allowed | -- | -- | 1 per building façade | |||||
| Maximum Area | -- | -- | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear foot of building front width, whichever is greatest1 | |||||
| Maximum Height | -- | -- | Above ground floor but no higher than the roofline | |||||
| Illumination | -- | -- | External downlighting | |||||
| Changeable Copy | -- | -- | Not permitted | |||||
| Projecting Signs | ||||||||
| Number Allowed | -- | 1 per tenant per building frontage and 1 per tenant in the alley of the building, if applicable | ||||||
| Maximum Area | -- | 12 sq. ft. per face or 24 sq. ft. per sign | ||||||
| Min./Max. Clearance Above Grade | -- | 8 ft./No higher than the ground floor | ||||||
| Illumination | -- | Internal, halo, or downlight | ||||||
| Changeable Copy | -- | Not Permitted | ||||||
| Wall Signs4 | ||||||||
| Number Allowed | 1 per tenant per building frontage | |||||||
| Maximum Area/Sign | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of façade width occupied by an individual business, whichever is greatest1 | |||||||
| Max. Clearance Above Grade | No higher than roof or parapet line2 | |||||||
| Maximum Projection from Wall | 12 inches | |||||||
| Illumination | External downlighting, internal, or halo | |||||||
| Changeable Copy | Not Permitted | |||||||
| Other Standards | Wall signs professionally painted directly onto a wall are deemed mural signs | |||||||
| Window Signs | ||||||||
| Number Allowed | 1 per tenant per building frontage | |||||||
| Maximum Area | 10% of combined area of all windows | |||||||
| Max. Clearance Above Grade | No higher than roof or parapet line | |||||||
| Illumination | Internal with nighttime NITs level not to exceed 500 nits | |||||||
| Changeable Copy | Not permitted | Permitted3 | ||||||
Table Notes:
"--" = Sign type is not permitted | ||||||||
Table 10-2-5.1.2 Attached Permanent Sign Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| DNR | DTA | DMS | DMU | |||||
| Arcade Sign | ||||||||
| Number Allowed | -- | -- | 1 per public entrance under arcade | |||||
| Maximum Area | -- | -- | 6 sq. ft. | |||||
| Minimum Clearance above Sidewalk | -- | -- | 8 ft. | |||||
| Illumination | -- | -- | External downlighting or halo | |||||
| Changeable Copy | -- | -- | Not permitted | |||||
| Awning Sign | ||||||||
| Number Allowed | -- | One per building façade or one per storefront for a mixed-use or multi-tenant building | ||||||
| Maximum Area | -- | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear foot of façade width, whichever is greatest1 | ||||||
| Minimum Vertical Clearance/ Maximum Height Above Grade | -- | 8 ft./ No higher than top of ground floor | ||||||
| Illumination | -- | External downlighting | ||||||
| Changeable Copy | -- | Not permitted | ||||||
| Marquee Signs | ||||||||
| Number Allowed | -- | -- | 1 per building front façade | |||||
| Maximum Area | -- | -- | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear foot of building front width, whichever is greatest1 | |||||
| Min./ Max. Clearance Above Grade | -- | -- | 12 ft./25 ft. | |||||
| Maximum Distance from Building Façade | -- | -- | 48 inches5 | |||||
| Illumination | -- | -- | Internal or halo | |||||
| Changeable Copy | -- | -- | Permitted | |||||
| Mural Sign | ||||||||
| Number Allowed | -- | -- | 1 per building façade | |||||
| Maximum Area | -- | -- | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear foot of building front width, whichever is greatest1 | |||||
| Maximum Height | -- | -- | Above ground floor but no higher than the roofline | |||||
| Illumination | -- | -- | External downlighting | |||||
| Changeable Copy | -- | -- | Not permitted | |||||
| Projecting Signs | ||||||||
| Number Allowed | -- | 1 per tenant per building frontage and 1 per tenant in the alley of the building, if applicable | ||||||
| Maximum Area | -- | 12 sq. ft. per face or 24 sq. ft. per sign | ||||||
| Min./Max. Clearance Above Grade | -- | 8 ft./No higher than the ground floor | ||||||
| Illumination | -- | Internal, halo, or downlight | ||||||
| Changeable Copy | -- | Not Permitted | ||||||
| Wall Signs4 | ||||||||
| Number Allowed | 1 per tenant per building frontage | |||||||
| Maximum Area/Sign | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of façade width occupied by an individual business, whichever is greatest1 | |||||||
| Max. Clearance Above Grade | No higher than roof or parapet line2 | |||||||
| Maximum Projection from Wall | 12 inches | |||||||
| Illumination | External downlighting, internal, or halo | |||||||
| Changeable Copy | Not Permitted | |||||||
| Other Standards | Wall signs professionally painted directly onto a wall are deemed mural signs | |||||||
| Window Signs | ||||||||
| Number Allowed | 1 per tenant per building frontage | |||||||
| Maximum Area | 10% of combined area of all windows | |||||||
| Max. Clearance Above Grade | No higher than roof or parapet line | |||||||
| Illumination | Internal with nighttime NITs level not to exceed 500 nits | |||||||
| Changeable Copy | Not permitted | Permitted3 | ||||||
Table Notes:
"--" = Sign type is not permitted | ||||||||
Table 10-2-5.1.2 Attached Permanent Sign Standards | ||||||||
|---|---|---|---|---|---|---|---|---|
| DNR | DTA | DMS | DMU | |||||
| Arcade Sign | ||||||||
| Number Allowed | -- | -- | 1 per public entrance under arcade | |||||
| Maximum Area | -- | -- | 6 sq. ft. | |||||
| Minimum Clearance above Sidewalk | -- | -- | 8 ft. | |||||
| Illumination | -- | -- | External downlighting or halo | |||||
| Changeable Copy | -- | -- | Not permitted | |||||
| Awning Sign | ||||||||
| Number Allowed | -- | One per building façade or one per storefront for a mixed-use or multi-tenant building | ||||||
| Maximum Area | -- | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear foot of façade width, whichever is greatest1 | ||||||
| Minimum Vertical Clearance/ Maximum Height Above Grade | -- | 8 ft./ No higher than top of ground floor | ||||||
| Illumination | -- | External downlighting | ||||||
| Changeable Copy | -- | Not permitted | ||||||
| Marquee Signs | ||||||||
| Number Allowed | -- | -- | 1 per building front façade | |||||
| Maximum Area | -- | -- | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear foot of building front width, whichever is greatest1 | |||||
| Min./ Max. Clearance Above Grade | -- | -- | 12 ft./25 ft. | |||||
| Maximum Distance from Building Façade | -- | -- | 48 inches5 | |||||
| Illumination | -- | -- | Internal or halo | |||||
| Changeable Copy | -- | -- | Permitted | |||||
| Mural Sign | ||||||||
| Number Allowed | -- | -- | 1 per building façade | |||||
| Maximum Area | -- | -- | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear foot of building front width, whichever is greatest1 | |||||
| Maximum Height | -- | -- | Above ground floor but no higher than the roofline | |||||
| Illumination | -- | -- | External downlighting | |||||
| Changeable Copy | -- | -- | Not permitted | |||||
| Projecting Signs | ||||||||
| Number Allowed | -- | 1 per tenant per building frontage and 1 per tenant in the alley of the building, if applicable | ||||||
| Maximum Area | -- | 12 sq. ft. per face or 24 sq. ft. per sign | ||||||
| Min./Max. Clearance Above Grade | -- | 8 ft./No higher than the ground floor | ||||||
| Illumination | -- | Internal, halo, or downlight | ||||||
| Changeable Copy | -- | Not Permitted | ||||||
| Wall Signs4 | ||||||||
| Number Allowed | 1 per tenant per building frontage | |||||||
| Maximum Area/Sign | 32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of façade width occupied by an individual business, whichever is greatest1 | |||||||
| Max. Clearance Above Grade | No higher than roof or parapet line2 | |||||||
| Maximum Projection from Wall | 12 inches | |||||||
| Illumination | External downlighting, internal, or halo | |||||||
| Changeable Copy | Not Permitted | |||||||
| Other Standards | Wall signs professionally painted directly onto a wall are deemed mural signs | |||||||
| Window Signs | ||||||||
| Number Allowed | 1 per tenant per building frontage | |||||||
| Maximum Area | 10% of combined area of all windows | |||||||
| Max. Clearance Above Grade | No higher than roof or parapet line | |||||||
| Illumination | Internal with nighttime NITs level not to exceed 500 nits | |||||||
| Changeable Copy | Not permitted | Permitted3 | ||||||
Table Notes:
"--" = Sign type is not permitted | ||||||||
Table 10-2-5.1.3 Detached Permanent Sign Standards | ||||
|---|---|---|---|---|
| DNR | DTA | DMS | DMU | |
| Monument Sign | ||||
| Number Allowed | 1 per street frontage |
| ||
| Maximum Area | 40 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width, whichever is greater1 | |||
| Maximum Height Above Grade | 5 ft. | 8 ft. | ||
| Illumination | Internally lit, Halo lit, or Externally downlit | |||
| Changeable Copy | Not permitted | Permitted2 | ||
| Pole Sign | ||||
| Number Allowed | -- | 1 per street frontage | -- | 1 per street frontage |
| Maximum Area | -- | 40 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width, whichever is greater1 | -- | 40 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width, whichever is greater1 |
| Maximum Height Above Grade | -- | 15 ft. | -- | 15 ft. |
| Illumination | -- | Halo | -- | Halo |
| Changeable Copy | -- | Not permitted | -- | Not permitted |
Table Notes:
"--" = The sign type is not permitted. | ||||
Table 10-2-5.1.3 Detached Permanent Sign Standards | ||||
|---|---|---|---|---|
| DNR | DTA | DMS | DMU | |
| Monument Sign | ||||
| Number Allowed | 1 per street frontage |
| ||
| Maximum Area | 40 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width, whichever is greater1 | |||
| Maximum Height Above Grade | 5 ft. | 8 ft. | ||
| Illumination | Internally lit, Halo lit, or Externally downlit | |||
| Changeable Copy | Not permitted | Permitted2 | ||
| Pole Sign | ||||
| Number Allowed | -- | 1 per street frontage | -- | 1 per street frontage |
| Maximum Area | -- | 40 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width, whichever is greater1 | -- | 40 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width, whichever is greater1 |
| Maximum Height Above Grade | -- | 15 ft. | -- | 15 ft. |
| Illumination | -- | Halo | -- | Halo |
| Changeable Copy | -- | Not permitted | -- | Not permitted |
Table Notes:
"--" = The sign type is not permitted. | ||||
Table 10-2-5.1.3 Detached Permanent Sign Standards | ||||
|---|---|---|---|---|
| DNR | DTA | DMS | DMU | |
| Monument Sign | ||||
| Number Allowed | 1 per street frontage |
| ||
| Maximum Area | 40 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width, whichever is greater1 | |||
| Maximum Height Above Grade | 5 ft. | 8 ft. | ||
| Illumination | Internally lit, Halo lit, or Externally downlit | |||
| Changeable Copy | Not permitted | Permitted2 | ||
| Pole Sign | ||||
| Number Allowed | -- | 1 per street frontage | -- | 1 per street frontage |
| Maximum Area | -- | 40 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width, whichever is greater1 | -- | 40 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width, whichever is greater1 |
| Maximum Height Above Grade | -- | 15 ft. | -- | 15 ft. |
| Illumination | -- | Halo | -- | Halo |
| Changeable Copy | -- | Not permitted | -- | Not permitted |
Table Notes:
"--" = The sign type is not permitted. | ||||
Table 10-2-5.1.3 Detached Permanent Sign Standards | ||||
|---|---|---|---|---|
| DNR | DTA | DMS | DMU | |
| Monument Sign | ||||
| Number Allowed | 1 per street frontage |
| ||
| Maximum Area | 40 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width, whichever is greater1 | |||
| Maximum Height Above Grade | 5 ft. | 8 ft. | ||
| Illumination | Internally lit, Halo lit, or Externally downlit | |||
| Changeable Copy | Not permitted | Permitted2 | ||
| Pole Sign | ||||
| Number Allowed | -- | 1 per street frontage | -- | 1 per street frontage |
| Maximum Area | -- | 40 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width, whichever is greater1 | -- | 40 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width, whichever is greater1 |
| Maximum Height Above Grade | -- | 15 ft. | -- | 15 ft. |
| Illumination | -- | Halo | -- | Halo |
| Changeable Copy | -- | Not permitted | -- | Not permitted |
Table Notes:
"--" = The sign type is not permitted. | ||||
(Ord. 18, Series of 2022; Ord. 20, Series of 2023)
Effective on: 10/13/2023
Figure 10-2-3.2.1 Single-Family Detached Building Type | |||||
|---|---|---|---|---|---|
![]() | |||||
![]()
| Primary entrance is oriented to the street and often defined by a porch. | ![]() | Some portion of the roof is pitched | ![]() | Walkway leads to the primary entrance from the public way. |
![]() | Autos access the property either from the alley or the street (where permitted) | ||||
Figure 10-2-3.2.1 Single-Family Detached Building Type | |||||
|---|---|---|---|---|---|
![]() | |||||
![]()
| Primary entrance is oriented to the street and often defined by a porch. | ![]() | Some portion of the roof is pitched | ![]() | Walkway leads to the primary entrance from the public way. |
![]() | Autos access the property either from the alley or the street (where permitted) | ||||
Figure 10-2-3.2.1 Single-Family Detached Building Type | |||||
|---|---|---|---|---|---|
![]() | |||||
![]()
| Primary entrance is oriented to the street and often defined by a porch. | ![]() | Some portion of the roof is pitched | ![]() | Walkway leads to the primary entrance from the public way. |
![]() | Autos access the property either from the alley or the street (where permitted) | ||||
Figure 10-2-3.2.1 Single-Family Detached Building Type | |||||
|---|---|---|---|---|---|
![]() | |||||
![]()
| Primary entrance is oriented to the street and often defined by a porch. | ![]() | Some portion of the roof is pitched | ![]() | Walkway leads to the primary entrance from the public way. |
![]() | Autos access the property either from the alley or the street (where permitted) | ||||
THE SAMPLE IMAGES BELOW ARE SHOWN ONLY FOR ILLUSTRATIVE PURPOSES AND ARE NOT MEANT TO PRESCRIBE THAT THESE FORMS MUST BE USED. | ||
|---|---|---|
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
Figure 10-2-3.2.2 Single-Family Detached Building Type (see Table 10-2-3.2.2, below) | |
|---|---|
![]() | ![]() |
| Building Placement and Building Coverage | Building Height and Upper Story Stepbacks |
![]() | ![]() |
| Building Activation | Building Form and Orientation |
Table 10-2-3.2.2 Single-Family Detached Building Type Standards (see Figure 10-2-3.2.2 above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 10’ / 20’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min. ft.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 65% | 65% | N/A | 70% |
| G | Public or Private Open Space and Tree Canopy Coverage (min. %) | 35% | 35% | N/A | 30% |
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | N/A | N/A | N/A |
| B | Maximum Height (number of stories/feet) | 2.5 / 30’ | 2.5 / 30’ | N/A | 2.5 / 30’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | N/A | N/A | N/A |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | N/A | N/A | N/A | N/A |
| Street Facing Wall Articulation | |||||
| C | Maximum façade width before articulation | 30’ | 30' | N/A | 30’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 1 | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques required (refer to Table 10-1-3.1.B for technique options) | N/A | N/A | N/A | N/A |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | N/A | N/A | N/A |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | N/A | N/A | N/A |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) percentage of building in plan view | 50% | 50% | N/A | 50% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Table 10-2-3.2.2 Single-Family Detached Building Type Standards (see Figure 10-2-3.2.2 above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 10’ / 20’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min. ft.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 65% | 65% | N/A | 70% |
| G | Public or Private Open Space and Tree Canopy Coverage (min. %) | 35% | 35% | N/A | 30% |
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | N/A | N/A | N/A |
| B | Maximum Height (number of stories/feet) | 2.5 / 30’ | 2.5 / 30’ | N/A | 2.5 / 30’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | N/A | N/A | N/A |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | N/A | N/A | N/A | N/A |
| Street Facing Wall Articulation | |||||
| C | Maximum façade width before articulation | 30’ | 30' | N/A | 30’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 1 | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques required (refer to Table 10-1-3.1.B for technique options) | N/A | N/A | N/A | N/A |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | N/A | N/A | N/A |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | N/A | N/A | N/A |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) percentage of building in plan view | 50% | 50% | N/A | 50% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Table 10-2-3.2.2 Single-Family Detached Building Type Standards (see Figure 10-2-3.2.2 above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 10’ / 20’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min. ft.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 65% | 65% | N/A | 70% |
| G | Public or Private Open Space and Tree Canopy Coverage (min. %) | 35% | 35% | N/A | 30% |
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | N/A | N/A | N/A |
| B | Maximum Height (number of stories/feet) | 2.5 / 30’ | 2.5 / 30’ | N/A | 2.5 / 30’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | N/A | N/A | N/A |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | N/A | N/A | N/A | N/A |
| Street Facing Wall Articulation | |||||
| C | Maximum façade width before articulation | 30’ | 30' | N/A | 30’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 1 | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques required (refer to Table 10-1-3.1.B for technique options) | N/A | N/A | N/A | N/A |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | N/A | N/A | N/A |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | N/A | N/A | N/A |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) percentage of building in plan view | 50% | 50% | N/A | 50% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Table 10-2-3.2.2 Single-Family Detached Building Type Standards (see Figure 10-2-3.2.2 above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 10’ / 20’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min. ft.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 65% | 65% | N/A | 70% |
| G | Public or Private Open Space and Tree Canopy Coverage (min. %) | 35% | 35% | N/A | 30% |
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | N/A | N/A | N/A |
| B | Maximum Height (number of stories/feet) | 2.5 / 30’ | 2.5 / 30’ | N/A | 2.5 / 30’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | N/A | N/A | N/A |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | N/A | N/A | N/A | N/A |
| Street Facing Wall Articulation | |||||
| C | Maximum façade width before articulation | 30’ | 30' | N/A | 30’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 1 | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques required (refer to Table 10-1-3.1.B for technique options) | N/A | N/A | N/A | N/A |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | N/A | N/A | N/A |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | N/A | N/A | N/A |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) percentage of building in plan view | 50% | 50% | N/A | 50% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Effective on: 1/1/1901
Figure 10-2-3.2.3 Single-Family Attached / Duplex Building Type | |||||
|---|---|---|---|---|---|
![]() | |||||
![]() | Primary entrance is oriented to the street and may be defined by a porch. | ![]() | Parking is subordinate to the primary building. | ![]() | Walkway leads to the primary entrance from the public way. |
| THE SAMPLE IMAGES BELOW ARE SHOWN ONLY FOR ILLUSTRATIVE PURPOSES AND ARE NOT MEANT TO PRESCRIBE THAT THESE FORMS MUST BE USED. | ||
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
Figure 10-2-3.2.4 Single-Family Attached / Duplex Building Type (see Table 10-2-3.2.3, below) | |
|---|---|
![]() | ![]() |
| Building Placement and Building Coverage | Building Height and Upper Story Stepbacks |
![]() |
![]() |
| Building Activation | Building Form and Orientation |
Table 10-2-3.2.3 Single-Family Attached / Duplex Building Type Standards (see Figure 10-2-3.2.4, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 20’ / 30’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min. ft.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5 |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 60% | 60% | N/A | 60% |
| G | Public or Private Open Space and Tree Canopy Coverage (min. %) | 30% | 30% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | 1 | N/A | N/A |
| B | Maximum Height (number of stories/feet) | 2.5 / 30’ | 2.5 / 30’ | N/A | 2.5 / 30’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | N/A | N/A | N/A |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | 30’ | 30’ | N/A | 30’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | 25’ | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 1 | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques required (refer to Table 10-1-3.1.B for technique options) | N/A | N/A | N/A | N/A |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | N/A | N/A | N/A |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | N/A | N/A | N/A |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) percentage of topmost floor | 50% | 50% | N/A | 50% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Table 10-2-3.2.3 Single-Family Attached / Duplex Building Type Standards (see Figure 10-2-3.2.4, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 20’ / 30’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min. ft.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5 |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 60% | 60% | N/A | 60% |
| G | Public or Private Open Space and Tree Canopy Coverage (min. %) | 30% | 30% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | 1 | N/A | N/A |
| B | Maximum Height (number of stories/feet) | 2.5 / 30’ | 2.5 / 30’ | N/A | 2.5 / 30’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | N/A | N/A | N/A |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | 30’ | 30’ | N/A | 30’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | 25’ | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 1 | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques required (refer to Table 10-1-3.1.B for technique options) | N/A | N/A | N/A | N/A |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | N/A | N/A | N/A |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | N/A | N/A | N/A |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) percentage of topmost floor | 50% | 50% | N/A | 50% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Table 10-2-3.2.3 Single-Family Attached / Duplex Building Type Standards (see Figure 10-2-3.2.4, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 20’ / 30’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min. ft.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5 |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 60% | 60% | N/A | 60% |
| G | Public or Private Open Space and Tree Canopy Coverage (min. %) | 30% | 30% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | 1 | N/A | N/A |
| B | Maximum Height (number of stories/feet) | 2.5 / 30’ | 2.5 / 30’ | N/A | 2.5 / 30’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | N/A | N/A | N/A |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | 30’ | 30’ | N/A | 30’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | 25’ | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 1 | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques required (refer to Table 10-1-3.1.B for technique options) | N/A | N/A | N/A | N/A |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | N/A | N/A | N/A |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | N/A | N/A | N/A |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) percentage of topmost floor | 50% | 50% | N/A | 50% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Table 10-2-3.2.3 Single-Family Attached / Duplex Building Type Standards (see Figure 10-2-3.2.4, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 20’ / 30’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min. ft.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5 |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 60% | 60% | N/A | 60% |
| G | Public or Private Open Space and Tree Canopy Coverage (min. %) | 30% | 30% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | 1 | N/A | N/A |
| B | Maximum Height (number of stories/feet) | 2.5 / 30’ | 2.5 / 30’ | N/A | 2.5 / 30’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | N/A | N/A | N/A |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | 30’ | 30’ | N/A | 30’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | 25’ | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 1 | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques required (refer to Table 10-1-3.1.B for technique options) | N/A | N/A | N/A | N/A |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | N/A | N/A | N/A |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | N/A | N/A | N/A |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) percentage of topmost floor | 50% | 50% | N/A | 50% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Effective on: 1/1/1901
Figure 10-2-3.2.5 Multiplex Building Type | |||||
|---|---|---|---|---|---|
![]() | |||||
![]() | Primary entrance is oriented to the street and may be defined by a porch. | ![]() | Pitched roof relates to traditional single-family buildings. | ![]() | Walkway leads to the primary entrance from the public way. |
| THE SAMPLE IMAGES BELOW ARE SHOWN ONLY FOR ILLUSTRATIVE PURPOSES AND ARE NOT MEANT TO PRESCRIBE THAT THESE FORMS MUST BE USED. | ||
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
Figure 10-2-3.2.6 Multiplex Building Type (see Table 10-2-3.2.4, below) | |
|---|---|
![]() | ![]() |
| Building Placement and Building Coverage | Building Height and Upper Story Stepbacks |
![]() |
![]() |
| Building Activation | Building Form and Orientation |
Table 10-2-3.2.4 Multiplex Building Type Standards (see Figure 10-2-3.2.6, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 20’ / 30’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min. ft.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 70% | 70% | N/A | 70% |
| G | Public Amenity / Outdoor Space and Tree Canopy Coverage (min. %) | 25% | 25% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | 2.5 / 30’ | 2.5 / 30' | N/A | 2.5 / 30' |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 20 ft. of a sensitive edge | N/A | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | 15’ | 15’ | N/A | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum wall length before articulation | 25’ | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 2 | 1 | N/A | 2 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | 2 | 1 | N/A | 2 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | 30% | 30% | N/A | 30% |
| G | Façade glazed: % upper floor(s) wall area (min.) | 20% | 20% | N/A | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) as percentage of building in plan view if not an art-deco or contemporary architectural style | 50% | 50% | N/A | 25% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation requirement | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Table 10-2-3.2.4 Multiplex Building Type Standards (see Figure 10-2-3.2.6, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 20’ / 30’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min. ft.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 70% | 70% | N/A | 70% |
| G | Public Amenity / Outdoor Space and Tree Canopy Coverage (min. %) | 25% | 25% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | 2.5 / 30’ | 2.5 / 30' | N/A | 2.5 / 30' |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 20 ft. of a sensitive edge | N/A | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | 15’ | 15’ | N/A | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum wall length before articulation | 25’ | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 2 | 1 | N/A | 2 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | 2 | 1 | N/A | 2 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | 30% | 30% | N/A | 30% |
| G | Façade glazed: % upper floor(s) wall area (min.) | 20% | 20% | N/A | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) as percentage of building in plan view if not an art-deco or contemporary architectural style | 50% | 50% | N/A | 25% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation requirement | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Table 10-2-3.2.4 Multiplex Building Type Standards (see Figure 10-2-3.2.6, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 20’ / 30’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min. ft.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 70% | 70% | N/A | 70% |
| G | Public Amenity / Outdoor Space and Tree Canopy Coverage (min. %) | 25% | 25% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | 2.5 / 30’ | 2.5 / 30' | N/A | 2.5 / 30' |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 20 ft. of a sensitive edge | N/A | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | 15’ | 15’ | N/A | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum wall length before articulation | 25’ | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 2 | 1 | N/A | 2 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | 2 | 1 | N/A | 2 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | 30% | 30% | N/A | 30% |
| G | Façade glazed: % upper floor(s) wall area (min.) | 20% | 20% | N/A | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) as percentage of building in plan view if not an art-deco or contemporary architectural style | 50% | 50% | N/A | 25% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation requirement | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Table 10-2-3.2.4 Multiplex Building Type Standards (see Figure 10-2-3.2.6, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 20’ / 30’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min. ft.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 70% | 70% | N/A | 70% |
| G | Public Amenity / Outdoor Space and Tree Canopy Coverage (min. %) | 25% | 25% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | 2.5 / 30’ | 2.5 / 30' | N/A | 2.5 / 30' |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 20 ft. of a sensitive edge | N/A | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | 15’ | 15’ | N/A | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum wall length before articulation | 25’ | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 2 | 1 | N/A | 2 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | 2 | 1 | N/A | 2 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | 30% | 30% | N/A | 30% |
| G | Façade glazed: % upper floor(s) wall area (min.) | 20% | 20% | N/A | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) as percentage of building in plan view if not an art-deco or contemporary architectural style | 50% | 50% | N/A | 25% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation requirement | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
(There are no ordinances associated with this section.)
Effective on: 10/13/2023
Description. This building type accommodates three to eight single-family units which are attached to one another and are oriented to the street. They are to be compatible in mass and scale with nearby residential structures of a lower scale. A Townhouse is one to three stories in height. The façade is designed to express each individual unit. Each unit has a principal entrance on the ground floor defined by a porch, stoop, or recessed entry. End units have window openings on three sides, while interior units have window openings only in the front and back. Parking is located in the rear. Figure 10-2-3.2.7, Townhouse Building Type, illustrates this building type.
Figure 10-2-3.2.7 Townhouse Building Type | |||||
|---|---|---|---|---|---|
![]() | |||||
![]() | Walkway leads to the primary entrance from the public way | ![]() | Articulation techniques provide variety in scale and add visual interest | ![]() | A primary entrance may be defined by a covered porch, stoop, or covered entry. |
| THE SAMPLE IMAGES BELOW ARE SHOWN ONLY FOR ILLUSTRATIVE PURPOSES AND ARE NOT MEANT TO PRESCRIBE THAT THESE FORMS MUST BE USED. | |
![]() | ![]() |
![]() | ![]() |
Figure 10-2-3.2.8 Townhouse Building Type (see Table 10-2-3.2.5, below) | |
|---|---|
![]() | ![]() |
| Building Placement and Building Coverage | Building Height and Upper Story Stepbacks |
![]() |
![]() |
| Building Activation | Building Form and Orientation |
Table 10-2-3.2.5 Townhouse Building Type Standards (see Figure 10-2-3.2.8 above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 20’ / 30’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 70% | 70% | N/A | 70% |
| G | Public Amenity / Open Space and Tree Canopy Coverage (min. %) | 25% | 25% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | 2.5 / 30' | 3 / 45’ | N/A | 3 / 45’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 20 ft. of a sensitive edge | 2 | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | 125’ | 125’ | N/A | 125’ |
| B | Blank Wall (max. ft.) | 15’ | 15’ | N/A | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | 25’ | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 1 | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | 1 | 1 | N/A | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | 30% | 30% | N/A | 30% |
| G | Façade glazed: % upper floor(s) wall area (min.) | 20% | 20% | N/A | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) percentage of topmost floor | 25% | 25% | N/A | 25% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Table 10-2-3.2.5 Townhouse Building Type Standards (see Figure 10-2-3.2.8 above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 20’ / 30’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 70% | 70% | N/A | 70% |
| G | Public Amenity / Open Space and Tree Canopy Coverage (min. %) | 25% | 25% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | 2.5 / 30' | 3 / 45’ | N/A | 3 / 45’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 20 ft. of a sensitive edge | 2 | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | 125’ | 125’ | N/A | 125’ |
| B | Blank Wall (max. ft.) | 15’ | 15’ | N/A | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | 25’ | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 1 | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | 1 | 1 | N/A | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | 30% | 30% | N/A | 30% |
| G | Façade glazed: % upper floor(s) wall area (min.) | 20% | 20% | N/A | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) percentage of topmost floor | 25% | 25% | N/A | 25% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Table 10-2-3.2.5 Townhouse Building Type Standards (see Figure 10-2-3.2.8 above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 20’ / 30’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 70% | 70% | N/A | 70% |
| G | Public Amenity / Open Space and Tree Canopy Coverage (min. %) | 25% | 25% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | 2.5 / 30' | 3 / 45’ | N/A | 3 / 45’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 20 ft. of a sensitive edge | 2 | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | 125’ | 125’ | N/A | 125’ |
| B | Blank Wall (max. ft.) | 15’ | 15’ | N/A | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | 25’ | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 1 | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | 1 | 1 | N/A | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | 30% | 30% | N/A | 30% |
| G | Façade glazed: % upper floor(s) wall area (min.) | 20% | 20% | N/A | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) percentage of topmost floor | 25% | 25% | N/A | 25% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Table 10-2-3.2.5 Townhouse Building Type Standards (see Figure 10-2-3.2.8 above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | 20’ / 30’ | 20’ / 30’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | 85% / 60% | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min.) | 10’ | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | 5’ | 5’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | 20' / 20’ | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | 70% | 70% | N/A | 70% |
| G | Public Amenity / Open Space and Tree Canopy Coverage (min. %) | 25% | 25% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within BTZ | 1 | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | 2.5 / 30' | 3 / 45’ | N/A | 3 / 45’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 20 ft. of a sensitive edge | 2 | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | 10' | 10' | N/A | 10' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | 125’ | 125’ | N/A | 125’ |
| B | Blank Wall (max. ft.) | 15’ | 15’ | N/A | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | 25’ | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | 1 | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | 1 | 1 | N/A | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | 30% | 30% | N/A | 30% |
| G | Façade glazed: % upper floor(s) wall area (min.) | 20% | 20% | N/A | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) percentage of topmost floor | 25% | 25% | N/A | 25% |
| Roof Slope | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | Directly facing the street | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | N/A | N/A | N/A |
Effective on: 1/1/1901
Figure 10-2-3.2.9 Apartment Building Type | |||||
|---|---|---|---|---|---|
![]() | |||||
![]() | Primary entrance orients to the street or a shared open space. | ![]() | Variation in massing and wall articulation provides visual interest and reduces perceived mass. | ![]() | Windows provide a sense of connection to the public way. |
| THE SAMPLE IMAGES BELOW ARE SHOWN ONLY FOR ILLUSTRATIVE PURPOSES AND ARE NOT MEANT TO PRESCRIBE THAT THESE FORMS MUST BE USED. | |
![]() | ![]() |
![]() | ![]() |
Figure 10-2-3.2.10 Apartment Building Type (see Table 10-2-3.2.6, below) | |
|---|---|
![]() | ![]() |
| Building Placement and Building Coverage | Building Height and Upper Story Stepbacks |
![]() | ![]() |
| Building Activation | Building Form and Orientation |
Table 10-2-3.2.6 Apartment Building Type Standards (see Figure 10-2-3.2.10, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 10’ / 30’ | N/A | 5’ / 20’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min.) | N/A | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 5’ | N/A | 5’ |
E | Rear Setback (min. ft. / min. ft. with alley)1 | N/A | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | N/A | 65% | N/A | 75% |
| G | Public Amenity / Outdoor Space and Tree Canopy Coverage (min. %) | N/A | 35% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | N/A | 4 / 55'’* |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | 80% |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 14’ | N/A | 14’ |
| *A maximum of four stories is permitted in the DMU character area that lies between Church Avenue and Alamo Avenue (but not abutting Alamo), and north of Berry Avenue, except in the white hatched area of the Character Map, where the maximum height is three stories / 45’. | |||||
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 125’ | N/A | 125’ |
| B | Blank Wall (max. ft.) | N/A | 20’ | N/A | 20’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | N/A | 3 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | N/A | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 40% | N/A | 40% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 30% | N/A | 30% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) as a percentage of building in plan view | N/A | 25% | N/A | N/A |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | N/A | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | 50’ | N/A | 50’ |
Table 10-2-3.2.6 Apartment Building Type Standards (see Figure 10-2-3.2.10, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 10’ / 30’ | N/A | 5’ / 20’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min.) | N/A | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 5’ | N/A | 5’ |
E | Rear Setback (min. ft. / min. ft. with alley)1 | N/A | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | N/A | 65% | N/A | 75% |
| G | Public Amenity / Outdoor Space and Tree Canopy Coverage (min. %) | N/A | 35% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | N/A | 4 / 55'’* |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | 80% |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 14’ | N/A | 14’ |
| *A maximum of four stories is permitted in the DMU character area that lies between Church Avenue and Alamo Avenue (but not abutting Alamo), and north of Berry Avenue, except in the white hatched area of the Character Map, where the maximum height is three stories / 45’. | |||||
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 125’ | N/A | 125’ |
| B | Blank Wall (max. ft.) | N/A | 20’ | N/A | 20’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | N/A | 3 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | N/A | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 40% | N/A | 40% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 30% | N/A | 30% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) as a percentage of building in plan view | N/A | 25% | N/A | N/A |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | N/A | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | 50’ | N/A | 50’ |
Table 10-2-3.2.6 Apartment Building Type Standards (see Figure 10-2-3.2.10, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 10’ / 30’ | N/A | 5’ / 20’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min.) | N/A | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 5’ | N/A | 5’ |
E | Rear Setback (min. ft. / min. ft. with alley)1 | N/A | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | N/A | 65% | N/A | 75% |
| G | Public Amenity / Outdoor Space and Tree Canopy Coverage (min. %) | N/A | 35% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | N/A | 4 / 55'’* |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | 80% |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 14’ | N/A | 14’ |
| *A maximum of four stories is permitted in the DMU character area that lies between Church Avenue and Alamo Avenue (but not abutting Alamo), and north of Berry Avenue, except in the white hatched area of the Character Map, where the maximum height is three stories / 45’. | |||||
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 125’ | N/A | 125’ |
| B | Blank Wall (max. ft.) | N/A | 20’ | N/A | 20’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | N/A | 3 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | N/A | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 40% | N/A | 40% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 30% | N/A | 30% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) as a percentage of building in plan view | N/A | 25% | N/A | N/A |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | N/A | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | 50’ | N/A | 50’ |
Table 10-2-3.2.6 Apartment Building Type Standards (see Figure 10-2-3.2.10, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 10’ / 30’ | N/A | 5’ / 20’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 85% / 60% | N/A | 85% / 60% |
| C | Corner Lot Side Setback (min.) | N/A | 10’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 5’ | N/A | 5’ |
E | Rear Setback (min. ft. / min. ft. with alley)1 | N/A | 15' / 20’ | N/A | 10' / 20’ |
| F | Building Coverage (max. %) | N/A | 65% | N/A | 75% |
| G | Public Amenity / Outdoor Space and Tree Canopy Coverage (min. %) | N/A | 35% | N/A | 25% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | N/A | 4 / 55'’* |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | 80% |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 14’ | N/A | 14’ |
| *A maximum of four stories is permitted in the DMU character area that lies between Church Avenue and Alamo Avenue (but not abutting Alamo), and north of Berry Avenue, except in the white hatched area of the Character Map, where the maximum height is three stories / 45’. | |||||
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 125’ | N/A | 125’ |
| B | Blank Wall (max. ft.) | N/A | 20’ | N/A | 20’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | N/A | 3 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | N/A | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 40% | N/A | 40% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 30% | N/A | 30% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) as a percentage of building in plan view | N/A | 25% | N/A | N/A |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | N/A | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | 50’ | N/A | 50’ |
Effective on: 1/1/1901
Figure 10-2-3.2.11 Live-Work Building Type | |||||
|---|---|---|---|---|---|
![]() | |||||
![]() | An easily identifiable entrance to the building. | ![]() | Step back of the upper floor reduces perceived mass. | ![]() | Transparency at the ground level engages the public way. |
| THE SAMPLE IMAGES BELOW ARE SHOWN ONLY FOR ILLUSTRATIVE PURPOSES AND ARE NOT MEANT TO PRESCRIBE THAT THESE FORMS MUST BE USED. | ||
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
Figure 10-2-3.2.12 Live-Work Building Type (see Table 10-2-3.2.7, below) | |
|---|---|
![]() | ![]() |
| Building Placement and Building Coverage | Building Height and Upper Story Stepbacks |
![]() | ![]() |
| Building Activation | Building Form and Orientation |
Table 10-2-3.2.7 Live-Work Building Type Standards (see Figure 10-2-3.2.12, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 5’ / 10’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 70% / 70% | N/A | 90% / 90% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 0’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | N/A | 10’ / 20' | N/A | 0’ ' 20' |
| F | Building Coverage (max. %) | N/A | 70% | N/A | 80% |
| G | Public Amenity / Open Space and Tree Canopy Coverage (min. %) | N/A | 30% | N/A | 20% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | N/A | 3 / 45’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 14’ | N/A | 14’ |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 125’ | N/A | 125’ |
| B | Blank Wall (max. ft.) | N/A | 20’ | N/A | 20’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | N/A | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 50% | N/A | 50% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 30% | N/A | 30% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | 50% | N/A | 50% |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | 50’ | N/A | 50’ |
Table 10-2-3.2.7 Live-Work Building Type Standards (see Figure 10-2-3.2.12, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 5’ / 10’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 70% / 70% | N/A | 90% / 90% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 0’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | N/A | 10’ / 20' | N/A | 0’ ' 20' |
| F | Building Coverage (max. %) | N/A | 70% | N/A | 80% |
| G | Public Amenity / Open Space and Tree Canopy Coverage (min. %) | N/A | 30% | N/A | 20% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | N/A | 3 / 45’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 14’ | N/A | 14’ |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 125’ | N/A | 125’ |
| B | Blank Wall (max. ft.) | N/A | 20’ | N/A | 20’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | N/A | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 50% | N/A | 50% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 30% | N/A | 30% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | 50% | N/A | 50% |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | 50’ | N/A | 50’ |
Table 10-2-3.2.7 Live-Work Building Type Standards (see Figure 10-2-3.2.12, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 5’ / 10’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 70% / 70% | N/A | 90% / 90% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 0’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | N/A | 10’ / 20' | N/A | 0’ ' 20' |
| F | Building Coverage (max. %) | N/A | 70% | N/A | 80% |
| G | Public Amenity / Open Space and Tree Canopy Coverage (min. %) | N/A | 30% | N/A | 20% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | N/A | 3 / 45’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 14’ | N/A | 14’ |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 125’ | N/A | 125’ |
| B | Blank Wall (max. ft.) | N/A | 20’ | N/A | 20’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | N/A | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 50% | N/A | 50% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 30% | N/A | 30% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | 50% | N/A | 50% |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | 50’ | N/A | 50’ |
Table 10-2-3.2.7 Live-Work Building Type Standards (see Figure 10-2-3.2.12, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 5’ / 10’ | N/A | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 70% / 70% | N/A | 90% / 90% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 0’ | N/A | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | N/A | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | N/A | 10’ / 20' | N/A | 0’ ' 20' |
| F | Building Coverage (max. %) | N/A | 70% | N/A | 80% |
| G | Public Amenity / Open Space and Tree Canopy Coverage (min. %) | N/A | 30% | N/A | 20% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | N/A | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | N/A | 3 / 45’ |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | N/A | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 14’ | N/A | 14’ |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 125’ | N/A | 125’ |
| B | Blank Wall (max. ft.) | N/A | 20’ | N/A | 20’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | N/A | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 1 | N/A | 1 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | N/A | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 50% | N/A | 50% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 30% | N/A | 30% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | 50% | N/A | 50% |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | N/A | Directly facing the street |
| C | Primary entrance spacing (max.) | N/A | 50’ | N/A | 50’ |
Effective on: 1/1/1901
Figure 10-2-3.2.12 Mixed-Use Building Type | |||||
|---|---|---|---|---|---|
![]() | |||||
![]() | An easily identifiable entrance to the building. | ![]() | Step back of the upper floor reduces perceived mass. | ![]() | Transparency at the ground level engages the public way. |
| THE SAMPLE IMAGES BELOW ARE SHOWN ONLY FOR ILLUSTRATIVE PURPOSES AND ARE NOT MEANT TO PRESCRIBE THAT THESE FORMS MUST BE USED. | ||
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
Figure 10-2-3.2.13 Mixed-Use Building Type (see Table 10-2-3.2.8, below) | |
|---|---|
![]() | ![]() |
| Building Placement and Building Coverage | Building Height and Upper Story Stepbacks |
![]() | ![]() |
| Building Activation | Building Form and Orientation |
Table 10-2-3.2.8 Mixed-Use Building Type Standards (see Figure 10-2-3.2.13, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 10’ / 20’ | 0’ / 5’ | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 70% / 70% | 80% / 80% | 80% / 80% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 0’ | 0’ | 10’ |
| D | Interior Lot Side Setback (min. ft.) | N/A | 0’ | 0’ | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | N/A | 10' / 10’ | 0’ / 10' | 0' / 10’ |
| F | Building Coverage (max. %) | N/A | 75% | 90% | 90% |
| G | Public Amenity / Open Space and Tree Canopy Coverage (min. %) | N/A | 25% | 0% | 10% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | 2 | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 4' / 55' | 3 / 45’ | 4 / 55' |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | 65% | N/A | 80% |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | 2 | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 15' | 15' | 15' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 150’ | 150’ | 150’ |
| B | Blank Wall (max. ft.) | N/A | 20’ | 20’ | 20’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade width before articulation is required (refer to Table 10-1-3.1.A for technique options) | N/A | 25’ | 25’ | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | 2 | 2 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques required | N/A | 1 | 1 | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 65% | 70% | 65% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 25% | 20% | 25% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | 25% | N/A | 25% |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | ||
| C | Primary entrance spacing (max.) | N/A | 50’ | 50’ | 50’ |
Table 10-2-3.2.8 Mixed-Use Building Type Standards (see Figure 10-2-3.2.13, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 10’ / 20’ | 0’ / 5’ | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 70% / 70% | 80% / 80% | 80% / 80% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 0’ | 0’ | 10’ |
| D | Interior Lot Side Setback (min. ft.) | N/A | 0’ | 0’ | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | N/A | 10' / 10’ | 0’ / 10' | 0' / 10’ |
| F | Building Coverage (max. %) | N/A | 75% | 90% | 90% |
| G | Public Amenity / Open Space and Tree Canopy Coverage (min. %) | N/A | 25% | 0% | 10% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | 2 | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 4' / 55' | 3 / 45’ | 4 / 55' |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | 65% | N/A | 80% |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | 2 | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 15' | 15' | 15' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 150’ | 150’ | 150’ |
| B | Blank Wall (max. ft.) | N/A | 20’ | 20’ | 20’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade width before articulation is required (refer to Table 10-1-3.1.A for technique options) | N/A | 25’ | 25’ | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | 2 | 2 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques required | N/A | 1 | 1 | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 65% | 70% | 65% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 25% | 20% | 25% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | 25% | N/A | 25% |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | ||
| C | Primary entrance spacing (max.) | N/A | 50’ | 50’ | 50’ |
Table 10-2-3.2.8 Mixed-Use Building Type Standards (see Figure 10-2-3.2.13, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 10’ / 20’ | 0’ / 5’ | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 70% / 70% | 80% / 80% | 80% / 80% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 0’ | 0’ | 10’ |
| D | Interior Lot Side Setback (min. ft.) | N/A | 0’ | 0’ | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | N/A | 10' / 10’ | 0’ / 10' | 0' / 10’ |
| F | Building Coverage (max. %) | N/A | 75% | 90% | 90% |
| G | Public Amenity / Open Space and Tree Canopy Coverage (min. %) | N/A | 25% | 0% | 10% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | 2 | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 4' / 55' | 3 / 45’ | 4 / 55' |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | 65% | N/A | 80% |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | 2 | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 15' | 15' | 15' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 150’ | 150’ | 150’ |
| B | Blank Wall (max. ft.) | N/A | 20’ | 20’ | 20’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade width before articulation is required (refer to Table 10-1-3.1.A for technique options) | N/A | 25’ | 25’ | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | 2 | 2 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques required | N/A | 1 | 1 | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 65% | 70% | 65% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 25% | 20% | 25% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | 25% | N/A | 25% |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | ||
| C | Primary entrance spacing (max.) | N/A | 50’ | 50’ | 50’ |
Table 10-2-3.2.8 Mixed-Use Building Type Standards (see Figure 10-2-3.2.13, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 10’ / 20’ | 0’ / 5’ | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 70% / 70% | 80% / 80% | 80% / 80% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 0’ | 0’ | 10’ |
| D | Interior Lot Side Setback (min. ft.) | N/A | 0’ | 0’ | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley)1 | N/A | 10' / 10’ | 0’ / 10' | 0' / 10’ |
| F | Building Coverage (max. %) | N/A | 75% | 90% | 90% |
| G | Public Amenity / Open Space and Tree Canopy Coverage (min. %) | N/A | 25% | 0% | 10% |
| |||||
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | 2 | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 4' / 55' | 3 / 45’ | 4 / 55' |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | 65% | N/A | 80% |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | 2 | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 15' | 15' | 15' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 150’ | 150’ | 150’ |
| B | Blank Wall (max. ft.) | N/A | 20’ | 20’ | 20’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade width before articulation is required (refer to Table 10-1-3.1.A for technique options) | N/A | 25’ | 25’ | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | 2 | 2 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques required | N/A | 1 | 1 | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 65% | 70% | 65% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 25% | 20% | 25% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | 25% | N/A | 25% |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | ||
| C | Primary entrance spacing (max.) | N/A | 50’ | 50’ | 50’ |
Effective on: 1/1/1901
Figure 10-2-3.2.14 Commercial Building Type | |||||
|---|---|---|---|---|---|
![]() | |||||
![]() | Primary entrance identified by raised parapet entry type and small plaza. | ![]() | Variation in roofline provides interest and reduces perceived scale | ![]() | Display windows face onto the public way |
| THE SAMPLE IMAGES BELOW ARE SHOWN ONLY FOR ILLUSTRATIVE PURPOSES AND ARE NOT MEANT TO PRESCRIBE THAT THESE FORMS MUST BE USED. | ||
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
Figure 10-2-3.2.15 Commercial Building Type (see Table 10-2-3.2.9, below) | |
|---|---|
![]() | ![]() |
| Building Placement and Building Coverage | Building Height and Upper Story Stepbacks |
![]() | ![]() |
| Building Activation | Building Form and Orientation |
Table 10-2-3.2.9 Commercial Building Type Standards (see Figure 10-2-3.2.15, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 10’ / 20’ | 0’ / 10’ | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 70% / 70% | 90% / 90% | 70% / 70% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 0’ | 0’ | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | 0’ | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | N/A | 10’ / 10' | 0’ / 10' | 0' / 10’ |
| F | Building Coverage (max. %) | N/A | 75% | 90% | 90% |
| G | Open Space and Tree Canopy Coverage (min. %) | N/A | 25% | 0% | 10% |
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | 2 | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | 3 / 45’ | 3 / 45 |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | 80% |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | 2 | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 15' | 15' | 15' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 180’ | 180’ | 180’ |
| B | Blank Wall (max. ft.) | N/A | 15’ | 15’ | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | 25’ | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | 3 | 3 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | 1 | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 40% | 60% | 40% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 20% | 20% | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) as percentage of building in plan view | N/A | 25% | N/A | 25% |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | ||
| C | Primary entrance spacing (max.) | N/A | 75’ | 75’ | 75’ |
Table 10-2-3.2.9 Commercial Building Type Standards (see Figure 10-2-3.2.15, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 10’ / 20’ | 0’ / 10’ | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 70% / 70% | 90% / 90% | 70% / 70% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 0’ | 0’ | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | 0’ | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | N/A | 10’ / 10' | 0’ / 10' | 0' / 10’ |
| F | Building Coverage (max. %) | N/A | 75% | 90% | 90% |
| G | Open Space and Tree Canopy Coverage (min. %) | N/A | 25% | 0% | 10% |
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | 2 | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | 3 / 45’ | 3 / 45 |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | 80% |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | 2 | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 15' | 15' | 15' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 180’ | 180’ | 180’ |
| B | Blank Wall (max. ft.) | N/A | 15’ | 15’ | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | 25’ | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | 3 | 3 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | 1 | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 40% | 60% | 40% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 20% | 20% | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) as percentage of building in plan view | N/A | 25% | N/A | 25% |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | ||
| C | Primary entrance spacing (max.) | N/A | 75’ | 75’ | 75’ |
Table 10-2-3.2.9 Commercial Building Type Standards (see Figure 10-2-3.2.15, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 10’ / 20’ | 0’ / 10’ | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 70% / 70% | 90% / 90% | 70% / 70% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 0’ | 0’ | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | 0’ | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | N/A | 10’ / 10' | 0’ / 10' | 0' / 10’ |
| F | Building Coverage (max. %) | N/A | 75% | 90% | 90% |
| G | Open Space and Tree Canopy Coverage (min. %) | N/A | 25% | 0% | 10% |
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | 2 | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | 3 / 45’ | 3 / 45 |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | 80% |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | 2 | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 15' | 15' | 15' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 180’ | 180’ | 180’ |
| B | Blank Wall (max. ft.) | N/A | 15’ | 15’ | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | 25’ | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | 3 | 3 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | 1 | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 40% | 60% | 40% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 20% | 20% | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) as percentage of building in plan view | N/A | 25% | N/A | 25% |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | ||
| C | Primary entrance spacing (max.) | N/A | 75’ | 75’ | 75’ |
Table 10-2-3.2.9 Commercial Building Type Standards (see Figure 10-2-3.2.15, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 10’ / 20’ | 0’ / 10’ | 0’ / 10’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 70% / 70% | 90% / 90% | 70% / 70% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 0’ | 0’ | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | 0’ | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | N/A | 10’ / 10' | 0’ / 10' | 0' / 10’ |
| F | Building Coverage (max. %) | N/A | 75% | 90% | 90% |
| G | Open Space and Tree Canopy Coverage (min. %) | N/A | 25% | 0% | 10% |
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | 2 | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | 3 / 45’ | 3 / 45 |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | 80% |
| D | Maximum number of stories within 10 ft. of a sensitive edge | N/A | 2 | 2 | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 15' | 15' | 15' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 180’ | 180’ | 180’ |
| B | Blank Wall (max. ft.) | N/A | 15’ | 15’ | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | 25’ | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | 3 | 3 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | 1 | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 40% | 60% | 40% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 20% | 20% | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip or gable) as percentage of building in plan view | N/A | 25% | N/A | 25% |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | ||
| C | Primary entrance spacing (max.) | N/A | 75’ | 75’ | 75’ |
Effective on: 1/1/1901
Figure 10-2-3.2.16 Office-Institutional Building Type | |||||
|---|---|---|---|---|---|
![]() | |||||
![]() | Primary entrance connects to a public walkway. | ![]() | Composition has a base, middle, and a cap with articulated walls and varied massing. | ![]() | A high degree of transparency activates the street level façade. |
| THE SAMPLE IMAGES BELOW ARE SHOWN ONLY FOR ILLUSTRATIVE PURPOSES AND ARE NOT MEANT TO PRESCRIBE THAT THESE FORMS MUST BE USED. | ||
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
Figure 10-2-3.2.17 Office - Institutional Building Type (see Table 10-2-3.2.10, below) | |
|---|---|
![]() | ![]() |
| Building Placement and Building Coverage | Building Height and Upper Story Stepbacks |
![]() |
![]() |
| Building Activation | Building Form and Orientation |
Table 10-2-3.2.10 Office - Institutional Building Type Standards (see Figure 10-2-3.2.17, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 5’ / 20’ | 0’ / 10’ | 0’ / 20’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 90% / 70% | 90% / 90% | 90% / 90% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 10’ | 10’ | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | 0’ | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | N/A | 10’ / 10' | 0’ / 10' | 0' / 10’ |
| F | Building Coverage (max. %) | N/A | 70% | 90% | 80% |
| G | Outdoor Space and Tree Canopy Coverage (min. %) | N/A | 30% | 0% | 20% |
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | 2 | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | 3 / 45' | 4 / 55'* |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | 80% |
| D | Maximum number of stories within 20 ft. of a sensitive edge | N/A | 2 | 2 | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 12' | 12' | 12' |
| * A maximum of three stories / 45’ stories is permitted in the DMU district. | |||||
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 150’ | 150’ | 100’ |
| B | Blank Wall (max. ft.) | N/A | 15’ | 15’ | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | 25’ | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | 2 | 3 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | 1 | 2 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 30% | 60% | 30% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 20% | 20% | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | 5% | N/A | N/A |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | N/A | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | ||
| C | Primary entrance spacing (max.) | N/A | 75’ | 75’ | 75’ |
Table 10-2-3.2.10 Office - Institutional Building Type Standards (see Figure 10-2-3.2.17, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 5’ / 20’ | 0’ / 10’ | 0’ / 20’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 90% / 70% | 90% / 90% | 90% / 90% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 10’ | 10’ | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | 0’ | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | N/A | 10’ / 10' | 0’ / 10' | 0' / 10’ |
| F | Building Coverage (max. %) | N/A | 70% | 90% | 80% |
| G | Outdoor Space and Tree Canopy Coverage (min. %) | N/A | 30% | 0% | 20% |
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | 2 | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | 3 / 45' | 4 / 55'* |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | 80% |
| D | Maximum number of stories within 20 ft. of a sensitive edge | N/A | 2 | 2 | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 12' | 12' | 12' |
| * A maximum of three stories / 45’ stories is permitted in the DMU district. | |||||
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 150’ | 150’ | 100’ |
| B | Blank Wall (max. ft.) | N/A | 15’ | 15’ | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | 25’ | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | 2 | 3 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | 1 | 2 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 30% | 60% | 30% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 20% | 20% | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | 5% | N/A | N/A |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | N/A | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | ||
| C | Primary entrance spacing (max.) | N/A | 75’ | 75’ | 75’ |
Table 10-2-3.2.10 Office - Institutional Building Type Standards (see Figure 10-2-3.2.17, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 5’ / 20’ | 0’ / 10’ | 0’ / 20’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 90% / 70% | 90% / 90% | 90% / 90% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 10’ | 10’ | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | 0’ | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | N/A | 10’ / 10' | 0’ / 10' | 0' / 10’ |
| F | Building Coverage (max. %) | N/A | 70% | 90% | 80% |
| G | Outdoor Space and Tree Canopy Coverage (min. %) | N/A | 30% | 0% | 20% |
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | 2 | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | 3 / 45' | 4 / 55'* |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | 80% |
| D | Maximum number of stories within 20 ft. of a sensitive edge | N/A | 2 | 2 | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 12' | 12' | 12' |
| * A maximum of three stories / 45’ stories is permitted in the DMU district. | |||||
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 150’ | 150’ | 100’ |
| B | Blank Wall (max. ft.) | N/A | 15’ | 15’ | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | 25’ | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | 2 | 3 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | 1 | 2 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 30% | 60% | 30% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 20% | 20% | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | 5% | N/A | N/A |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | N/A | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | ||
| C | Primary entrance spacing (max.) | N/A | 75’ | 75’ | 75’ |
Table 10-2-3.2.10 Office - Institutional Building Type Standards (see Figure 10-2-3.2.17, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 5’ / 20’ | 0’ / 10’ | 0’ / 20’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 90% / 70% | 90% / 90% | 90% / 90% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 10’ | 10’ | 10’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | 0’ | 5’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | N/A | 10’ / 10' | 0’ / 10' | 0' / 10’ |
| F | Building Coverage (max. %) | N/A | 70% | 90% | 80% |
| G | Outdoor Space and Tree Canopy Coverage (min. %) | N/A | 30% | 0% | 20% |
| Building Height and Upper Story Stepbacks | |||||
| A | Maximum number of stories within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 | 2 | 2 |
| B | Maximum Height (number of stories/feet) | N/A | 3 / 45’ | 3 / 45' | 4 / 55'* |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | 80% |
| D | Maximum number of stories within 20 ft. of a sensitive edge | N/A | 2 | 2 | 2 |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) | N/A | 12' | 12' | 12' |
| * A maximum of three stories / 45’ stories is permitted in the DMU district. | |||||
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | 150’ | 150’ | 100’ |
| B | Blank Wall (max. ft.) | N/A | 15’ | 15’ | 15’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length before articulation | N/A | 25’ | 25’ | 25’ |
| D | Minimum number of articulation techniques required (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | 2 | 3 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques (refer to Table 10-1-3.1.B for technique options) | N/A | 1 | 1 | 2 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) | N/A | 30% | 60% | 30% |
| G | Façade glazed: % upper floor(s) wall area (min.) | N/A | 20% | 20% | 20% |
| Building Form and Orientation | |||||
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | 5% | N/A | N/A |
| Roof Slope | N/A | 5:12 or steeper 3:12 or steeper for porches, add-ons, etc. | N/A | N/A | |
| Building Entry | |||||
| B | Primary entrance orientation | N/A | Directly facing the street | ||
| C | Primary entrance spacing (max.) | N/A | 75’ | 75’ | 75’ |
Effective on: 1/1/1901
Figure 10-2-3.2.18 Parking Structure Building Type | |||||
|---|---|---|---|---|---|
![]() | |||||
![]() | Activated street level “wrap”. | ![]() | Architectural screening of parking levels. | ![]() | Varied massing and articulation. |
| THE SAMPLE IMAGES BELOW ARE SHOWN ONLY FOR ILLUSTRATIVE PURPOSES AND ARE NOT MEANT TO PRESCRIBE THAT THESE FORMS MUST BE USED. | |||
![]() | ![]() | ![]() | |
![]() | ![]() | ||
Figure 10-2-3.2.19 Parking Structure Building Type (see Table 10-2-3.2.11, below) | |
|---|---|
![]() | ![]() |
| Building Placement and Building Coverage | Building Height and Upper Story Stepbacks |
![]() | ![]() |
| Building Activation | Building Form and Orientation |
Table 10-2-3.2.11 Parking Structure Building Type Standards (see Figure 10-2-3.2.19, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 20’ / 30’ | 20’ / 30’ | 20’ / 30’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 90% / 70% | 90% / 90% | 90% / 90% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 10’ | 1’ | 15’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | 0’ | 10’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | N/A | 15’ / 24' | 0’ / 24' | 10’ / 24' |
| F | Building Coverage (max. %) | N/A | 75% | 90% | 90% |
| G | Open Space and Tree Canopy Coverage (min. %) | N/A | 25% | 0% | 10% |
| Building Height and Upper Story Stepbacks (For building wrap) | |||||
| A | Maximum number of stories/feet of a “wrap” within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 / 30' | 2 / 30' | 2 / 30' |
| B | Maximum number of stories/feet of a “wrap” | N/A | 3 / 45' | 3 / 45' | 3 / 45' |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories/feet of a “wrap” within 10 ft. of a sensitive edge | N/A | 2 / 30' | 2 / 30' | 2 / 30' |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) of a “wrap” | N/A | 16' | 16' | 16' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | N/A | 50’ | 50’ | 50’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length of “wrap” before articulation | N/A | 50’ | 50’ | 50’ |
| D | Minimum number of articulation techniques required for “wrap” (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | 2 | 2 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques for “wrap” | N/A | 1 | 1 | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) for “wrap” | N/A | 50% | 50% | 50% |
| G | Façade glazed: % upper floor(s) wall area (min.) for “wrap” | N/A | 30% | 30% | 30% |
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | N/A | N/A | N/A |
| Building Entry | |||||
| A | Primary entrance orientation for “wrap” | N/A | Directly facing the street | ||
| B | Primary entrance spacing (max.) for “wrap” (not including vehicle entries) | N/A | 50’ | 50’ | 50’ |
Table 10-2-3.2.11 Parking Structure Building Type Standards (see Figure 10-2-3.2.19, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 20’ / 30’ | 20’ / 30’ | 20’ / 30’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 90% / 70% | 90% / 90% | 90% / 90% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 10’ | 1’ | 15’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | 0’ | 10’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | N/A | 15’ / 24' | 0’ / 24' | 10’ / 24' |
| F | Building Coverage (max. %) | N/A | 75% | 90% | 90% |
| G | Open Space and Tree Canopy Coverage (min. %) | N/A | 25% | 0% | 10% |
| Building Height and Upper Story Stepbacks (For building wrap) | |||||
| A | Maximum number of stories/feet of a “wrap” within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 / 30' | 2 / 30' | 2 / 30' |
| B | Maximum number of stories/feet of a “wrap” | N/A | 3 / 45' | 3 / 45' | 3 / 45' |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories/feet of a “wrap” within 10 ft. of a sensitive edge | N/A | 2 / 30' | 2 / 30' | 2 / 30' |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) of a “wrap” | N/A | 16' | 16' | 16' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | N/A | 50’ | 50’ | 50’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length of “wrap” before articulation | N/A | 50’ | 50’ | 50’ |
| D | Minimum number of articulation techniques required for “wrap” (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | 2 | 2 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques for “wrap” | N/A | 1 | 1 | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) for “wrap” | N/A | 50% | 50% | 50% |
| G | Façade glazed: % upper floor(s) wall area (min.) for “wrap” | N/A | 30% | 30% | 30% |
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | N/A | N/A | N/A |
| Building Entry | |||||
| A | Primary entrance orientation for “wrap” | N/A | Directly facing the street | ||
| B | Primary entrance spacing (max.) for “wrap” (not including vehicle entries) | N/A | 50’ | 50’ | 50’ |
Table 10-2-3.2.11 Parking Structure Building Type Standards (see Figure 10-2-3.2.19, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 20’ / 30’ | 20’ / 30’ | 20’ / 30’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 90% / 70% | 90% / 90% | 90% / 90% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 10’ | 1’ | 15’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | 0’ | 10’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | N/A | 15’ / 24' | 0’ / 24' | 10’ / 24' |
| F | Building Coverage (max. %) | N/A | 75% | 90% | 90% |
| G | Open Space and Tree Canopy Coverage (min. %) | N/A | 25% | 0% | 10% |
| Building Height and Upper Story Stepbacks (For building wrap) | |||||
| A | Maximum number of stories/feet of a “wrap” within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 / 30' | 2 / 30' | 2 / 30' |
| B | Maximum number of stories/feet of a “wrap” | N/A | 3 / 45' | 3 / 45' | 3 / 45' |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories/feet of a “wrap” within 10 ft. of a sensitive edge | N/A | 2 / 30' | 2 / 30' | 2 / 30' |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) of a “wrap” | N/A | 16' | 16' | 16' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | N/A | 50’ | 50’ | 50’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length of “wrap” before articulation | N/A | 50’ | 50’ | 50’ |
| D | Minimum number of articulation techniques required for “wrap” (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | 2 | 2 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques for “wrap” | N/A | 1 | 1 | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) for “wrap” | N/A | 50% | 50% | 50% |
| G | Façade glazed: % upper floor(s) wall area (min.) for “wrap” | N/A | 30% | 30% | 30% |
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | N/A | N/A | N/A |
| Building Entry | |||||
| A | Primary entrance orientation for “wrap” | N/A | Directly facing the street | ||
| B | Primary entrance spacing (max.) for “wrap” (not including vehicle entries) | N/A | 50’ | 50’ | 50’ |
Table 10-2-3.2.11 Parking Structure Building Type Standards (see Figure 10-2-3.2.19, above) | |||||
|---|---|---|---|---|---|
| Symbol | Standard | DNR | DTA | DMS | DMU |
| Building Placement and Building Coverage | |||||
| A | Build-to Zone (BTZ) (min. / max. ft.) | N/A | 20’ / 30’ | 20’ / 30’ | 20’ / 30’ |
| B | Primary / Secondary Street Frontage (min. % of façade in BTZ) | N/A | 90% / 70% | 90% / 90% | 90% / 90% |
| C | Corner Lot Side Setback (min. ft.) | N/A | 10’ | 1’ | 15’ |
| D | Interior Side Setback (min. ft.) | N/A | 0’ | 0’ | 10’ |
| E | Rear Setback (min. ft. / min. ft. with alley) | N/A | 15’ / 24' | 0’ / 24' | 10’ / 24' |
| F | Building Coverage (max. %) | N/A | 75% | 90% | 90% |
| G | Open Space and Tree Canopy Coverage (min. %) | N/A | 25% | 0% | 10% |
| Building Height and Upper Story Stepbacks (For building wrap) | |||||
| A | Maximum number of stories/feet of a “wrap” within 20 ft. of front property line (stepback distance of 20 ft.) | N/A | 2 / 30' | 2 / 30' | 2 / 30' |
| B | Maximum number of stories/feet of a “wrap” | N/A | 3 / 45' | 3 / 45' | 3 / 45' |
| C | Maximum 4th-floor plate area (percentage of 3rd-floor area) | N/A | N/A | N/A | N/A |
| D | Maximum number of stories/feet of a “wrap” within 10 ft. of a sensitive edge | N/A | 2 / 30' | 2 / 30' | 2 / 30' |
| E | Ground Floor - Floor-to-Floor Height (max. ft.) of a “wrap” | N/A | 16' | 16' | 16' |
| Building Activation | |||||
| Street Facing Wall Lengths | |||||
| A | Overall (max. ft.) | N/A | N/A | N/A | N/A |
| B | Blank Wall (max. ft.) | N/A | 50’ | 50’ | 50’ |
| Street Facing Wall Articulation | |||||
| C | Maximum façade length of “wrap” before articulation | N/A | 50’ | 50’ | 50’ |
| D | Minimum number of articulation techniques required for “wrap” (refer to Table 10-1-3.1.A for technique options) | N/A | 2 | 2 | 2 |
| Mass Variation | |||||
| E | Minimum number of varied massing techniques for “wrap” | N/A | 1 | 1 | 1 |
| Transparency | |||||
| F | Façade glazed: % ground floor wall area (min.) for “wrap” | N/A | 50% | 50% | 50% |
| G | Façade glazed: % upper floor(s) wall area (min.) for “wrap” | N/A | 30% | 30% | 30% |
| Roof Form | |||||
| A | Minimum sloping roof form (hip, shed, or gable) as percentage of building in plan view | N/A | N/A | N/A | N/A |
| Building Entry | |||||
| A | Primary entrance orientation for “wrap” | N/A | Directly facing the street | ||
| B | Primary entrance spacing (max.) for “wrap” (not including vehicle entries) | N/A | 50’ | 50’ | 50’ |
Effective on: 1/1/1901