Zoneomics Logo
search icon

Littleton City Zoning Code

CHAPTER 3

CORRIDORS AND MIXED-USE CMU

Related Provisions
Sec. 10-1-1.1Base DistrictsDistrict purposes and relationships between the ULUC zoning districts, the former districts, and the Land Use and Character Map
Sec. 10-1-1.2Overlay and Special DistrictsProcedures for the transition of the PD and PDO districts to a PL-O, Planned Overlay, and their termination or expiration
Sec. 10-1-1.3Land Use MatrixPermitted, specially permitted, conditional, and accessory permitted within the NC and CM districts
Sec. 10-1-1.4Land Use StandardsStandards that apply to land uses denoted with an "S" in Section 10-1-1.3, Land Use Matrix
Sec. 10-9-5.1Conditional Use StandardsStandards for land uses denoted as "C" in Section 10-1-1.3, Land Use Matrix
Sec. 10-1-2.3Height and Yard ExceptionsAllowable exceptions to the setbacks and heights within the NC and CM districts
Sec. 10-1-3.1General Design StandardsStandards relating to wall articulation, varied massing, blank walls, and screening
Sec. 10-1-3.2Non-Residential and Mixed-Use Design StandardsPermitted and alternative materials and CPTED review standards
Sec. 10-9-5.8Adaptive Reuse PlanDevelopment standards and reuse incentives for the revitalization or redevelopment of buildings
Sec. 10-1-3.4Sustainable Building DesignIncentives for the use of sustainable design and development practices
Sec. 10-1-3.5Transition StandardsRequirements for building setbacks and stepbacks to transition the intensity of development when sharing a property line of rights-of-way with districts of lesser intensity
Sec. 10-1-3.7Vehicle MobilityMinimum required and maximum allowable parking and loading spaces, design standards, and maintenance requirements
Sec. 10-1-3.8Alternative MobilityOn-site pedestrian access and circulation standards and bicycle parking requirements
Sec. 10-1-3.9Managed AccessAccess locations, spacing and dimensional requirements and sight triangle standards
Sec. 10-1-3.11Outdoor Lighting StandardsStandards for on-site exterior lighting and for certain districts, uses and site features
Sec. 10-6-2.3Subdivision DesignStandards for streets, blocks, lots, easements, open space and public utilities and infrastructure
Sec. 10-7-1.5Floodplain / Flood Fringe RegulationsRequirements for subdivisions, construction and critical facility standards, and alterations of watercourses
Sec. 10-9-3.9Development Review SummaryDescriptions of all required approval and permit processes
Sec. 10-12-2.1DefinitionsDefinitions of land uses and general terms
Base Standards
Sec. 10-1-3.6Greenspace Design StandardsGeneral planting, landscape, bufferyard and tree canopy coverage requirements
Sec. 10-1-3.10Sign StandardsSigns allowed and prohibited, installation and maintenance requirements, means of measuring sign dimensions, bonuses, and standards for temporary signs
Related Provisions
Sec. 10-1-1.1Base DistrictsDistrict purposes and relationships between the ULUC zoning districts, the former districts, and the Land Use and Character Map
Sec. 10-1-1.2Overlay and Special DistrictsProcedures for the transition of the PD and PDO districts to a PL-O, Planned Overlay, and their termination or expiration
Sec. 10-1-1.3Land Use MatrixPermitted, specially permitted, conditional, and accessory permitted within the NC and CM districts
Sec. 10-1-1.4Land Use StandardsStandards that apply to land uses denoted with an "S" in Section 10-1-1.3, Land Use Matrix
Sec. 10-9-5.1Conditional Use StandardsStandards for land uses denoted as "C" in Section 10-1-1.3, Land Use Matrix
Sec. 10-1-2.3Height and Yard ExceptionsAllowable exceptions to the setbacks and heights within the NC and CM districts
Sec. 10-1-3.1General Design StandardsStandards relating to wall articulation, varied massing, blank walls, and screening
Sec. 10-1-3.2Non-Residential and Mixed-Use Design StandardsPermitted and alternative materials and CPTED review standards
Sec. 10-9-5.8Adaptive Reuse PlanDevelopment standards and reuse incentives for the revitalization or redevelopment of buildings
Sec. 10-1-3.4Sustainable Building DesignIncentives for the use of sustainable design and development practices
Sec. 10-1-3.5Transition StandardsRequirements for building setbacks and stepbacks to transition the intensity of development when sharing a property line of rights-of-way with districts of lesser intensity
Sec. 10-1-3.7Vehicle MobilityMinimum required and maximum allowable parking and loading spaces, design standards, and maintenance requirements
Sec. 10-1-3.8Alternative MobilityOn-site pedestrian access and circulation standards and bicycle parking requirements
Sec. 10-1-3.9Managed AccessAccess locations, spacing and dimensional requirements and sight triangle standards
Sec. 10-1-3.11Outdoor Lighting StandardsStandards for on-site exterior lighting and for certain districts, uses and site features
Sec. 10-6-2.3Subdivision DesignStandards for streets, blocks, lots, easements, open space and public utilities and infrastructure
Sec. 10-7-1.5Floodplain / Flood Fringe RegulationsRequirements for subdivisions, construction and critical facility standards, and alterations of watercourses
Sec. 10-9-3.9Development Review SummaryDescriptions of all required approval and permit processes
Sec. 10-12-2.1DefinitionsDefinitions of land uses and general terms
Base Standards
Sec. 10-1-3.6Greenspace Design StandardsGeneral planting, landscape, bufferyard and tree canopy coverage requirements
Sec. 10-1-3.10Sign StandardsSigns allowed and prohibited, installation and maintenance requirements, means of measuring sign dimensions, bonuses, and standards for temporary signs
Related Provisions
Sec. 10-1-1.1Base DistrictsDistrict purposes and relationships between the ULUC zoning districts, the former districts, and the Land Use and Character Map
Sec. 10-1-1.2Overlay and Special DistrictsProcedures for the transition of the PD and PDO districts to a PL-O, Planned Overlay, and their termination or expiration
Sec. 10-1-1.3Land Use MatrixPermitted, specially permitted, conditional, and accessory permitted within the NC and CM districts
Sec. 10-1-1.4Land Use StandardsStandards that apply to land uses denoted with an "S" in Section 10-1-1.3, Land Use Matrix
Sec. 10-9-5.1Conditional Use StandardsStandards for land uses denoted as "C" in Section 10-1-1.3, Land Use Matrix
Sec. 10-1-2.3Height and Yard ExceptionsAllowable exceptions to the setbacks and heights within the NC and CM districts
Sec. 10-1-3.1General Design StandardsStandards relating to wall articulation, varied massing, blank walls, and screening
Sec. 10-1-3.2Non-Residential and Mixed-Use Design StandardsPermitted and alternative materials and CPTED review standards
Sec. 10-9-5.8Adaptive Reuse PlanDevelopment standards and reuse incentives for the revitalization or redevelopment of buildings
Sec. 10-1-3.4Sustainable Building DesignIncentives for the use of sustainable design and development practices
Sec. 10-1-3.5Transition StandardsRequirements for building setbacks and stepbacks to transition the intensity of development when sharing a property line of rights-of-way with districts of lesser intensity
Sec. 10-1-3.7Vehicle MobilityMinimum required and maximum allowable parking and loading spaces, design standards, and maintenance requirements
Sec. 10-1-3.8Alternative MobilityOn-site pedestrian access and circulation standards and bicycle parking requirements
Sec. 10-1-3.9Managed AccessAccess locations, spacing and dimensional requirements and sight triangle standards
Sec. 10-1-3.11Outdoor Lighting StandardsStandards for on-site exterior lighting and for certain districts, uses and site features
Sec. 10-6-2.3Subdivision DesignStandards for streets, blocks, lots, easements, open space and public utilities and infrastructure
Sec. 10-7-1.5Floodplain / Flood Fringe RegulationsRequirements for subdivisions, construction and critical facility standards, and alterations of watercourses
Sec. 10-9-3.9Development Review SummaryDescriptions of all required approval and permit processes
Sec. 10-12-2.1DefinitionsDefinitions of land uses and general terms
Base Standards
Sec. 10-1-3.6Greenspace Design StandardsGeneral planting, landscape, bufferyard and tree canopy coverage requirements
Sec. 10-1-3.10Sign StandardsSigns allowed and prohibited, installation and maintenance requirements, means of measuring sign dimensions, bonuses, and standards for temporary signs
Related Provisions
Sec. 10-1-1.1Base DistrictsDistrict purposes and relationships between the ULUC zoning districts, the former districts, and the Land Use and Character Map
Sec. 10-1-1.2Overlay and Special DistrictsProcedures for the transition of the PD and PDO districts to a PL-O, Planned Overlay, and their termination or expiration
Sec. 10-1-1.3Land Use MatrixPermitted, specially permitted, conditional, and accessory permitted within the NC and CM districts
Sec. 10-1-1.4Land Use StandardsStandards that apply to land uses denoted with an "S" in Section 10-1-1.3, Land Use Matrix
Sec. 10-9-5.1Conditional Use StandardsStandards for land uses denoted as "C" in Section 10-1-1.3, Land Use Matrix
Sec. 10-1-2.3Height and Yard ExceptionsAllowable exceptions to the setbacks and heights within the NC and CM districts
Sec. 10-1-3.1General Design StandardsStandards relating to wall articulation, varied massing, blank walls, and screening
Sec. 10-1-3.2Non-Residential and Mixed-Use Design StandardsPermitted and alternative materials and CPTED review standards
Sec. 10-9-5.8Adaptive Reuse PlanDevelopment standards and reuse incentives for the revitalization or redevelopment of buildings
Sec. 10-1-3.4Sustainable Building DesignIncentives for the use of sustainable design and development practices
Sec. 10-1-3.5Transition StandardsRequirements for building setbacks and stepbacks to transition the intensity of development when sharing a property line of rights-of-way with districts of lesser intensity
Sec. 10-1-3.7Vehicle MobilityMinimum required and maximum allowable parking and loading spaces, design standards, and maintenance requirements
Sec. 10-1-3.8Alternative MobilityOn-site pedestrian access and circulation standards and bicycle parking requirements
Sec. 10-1-3.9Managed AccessAccess locations, spacing and dimensional requirements and sight triangle standards
Sec. 10-1-3.11Outdoor Lighting StandardsStandards for on-site exterior lighting and for certain districts, uses and site features
Sec. 10-6-2.3Subdivision DesignStandards for streets, blocks, lots, easements, open space and public utilities and infrastructure
Sec. 10-7-1.5Floodplain / Flood Fringe RegulationsRequirements for subdivisions, construction and critical facility standards, and alterations of watercourses
Sec. 10-9-3.9Development Review SummaryDescriptions of all required approval and permit processes
Sec. 10-12-2.1DefinitionsDefinitions of land uses and general terms
Base Standards
Sec. 10-1-3.6Greenspace Design StandardsGeneral planting, landscape, bufferyard and tree canopy coverage requirements
Sec. 10-1-3.10Sign StandardsSigns allowed and prohibited, installation and maintenance requirements, means of measuring sign dimensions, bonuses, and standards for temporary signs

(Ord. 20, Series of 2023) 

Section 10-3-1.1 CMU Purpose

The purpose of this Chapter is to establish the districts and standards to implement the corresponding designations of the Future Land Use and Character Map set forth in the adopted Comprehensive Plan. More specifically, the Neighborhood Commercial (NC) and Corridor Mixed (CM) districts are designed to:

  • Provide for neighborhood-serving uses on lots near single-family dwellings where there are scale and transition standards to protect neighborhood character;

  • Establish frontage standards that relate the context of the proposed development with the building placements of the adjoining properties and surrounding environment;
  • Create site design standards that provide on-site open space to be used for landscaping, screening, and buffering, to preserve trees and other vegetation, and to achieve sustainable development objectives;
  • Provide ample areas that are suitable for corporate offices, technology, and manufacturing facilities that help to strengthen the tax base and provide for local employment;

  • Promote walkable mixed-use centers that support transit usage, provide opportunities for additional housing types and formats, and increase non-residential floor area; and

  • Encourage good standards of site planning, sustainable design, architecture, and landscape design to maintain quality of place and a desirable community character.

Effective on: 10/28/2021

Section 10-3-1.2 CMU Applicability

The provisions of this Chapter apply to land that is depicted on the Future Land Use and Character Map as Corridor Mixed-Use. The applicable zoning districts include Neighborhood Commercial (NC) and Corridor Mixed (CM), as set out in Section 10-1-1.1, Base Districts.

Effective on: 10/28/2021

Section 10-3-2.1 CMU Districts and Uses

  • A.
    Districts.
    1. 1.
      Plan Implementation. The zoning districts that implement the Corridor Mixed-Use designation on the Future Land Use and Character Map include:
      1. a.
        NC, Neighborhood Commercial; and
      2. b.
        CM, Corridor Mixed.
    2. 2.
      Purposes. The purposes of these districts and their relationships to the Comprehensive Plan and former zoning designations are set out in Section 10-1-1.1, Base Districts.
  • B.
    Land Uses. The land uses are organized by general and specific use categories. As set out in Table 10-1-1.3.1, Land Use Matrix, each land use is indicated as being Permitted (P), permitted subject to special Standards (S), permitted subject to approval of the Conditional Use (C), Accessory (A), or Prohibited (--). If additional standards apply to land uses, the applicable sections are cross-referenced in the far right column of the land use matrix.
  • Effective on: 10/28/2021

    Section 10-3-2.2 CMU Lot and Building Standards

  • A.
    Purpose. This Section establishes the development standards for residential, non-residential, and mixed-use buildings in the NC and CM districts, as shown in:
    1. 1.
      Residential. See Table 10-3-2.2.1, Residential Lot and Building Standards; and
    2. 2.
      Non-Residential and Mixed-Use. See Table 10-3-2.2.2, Non-Residential and Mixed-Use Lot and Building Standards.
  • B.
    Applicability.
    1. 1.
      Residential Lots and Building Standards.
      1. a.
        The standards in Table 10-3-2.2.1, Residential Lot and Building Standards, apply to new residential development within the Neighborhood Commercial (NC) and Corridor Mixed (CM) district.
      2. b.
        Construction or reconstruction of residential dwellings in pre-established neighborhoods within the CM district shall conform to the standards of Subsection 10-4-3.2.C, Contextual Development.
      3. c.
        Additions or expansions to existing single-family detached dwellings in pre-established neighborhoods within the CM district shall conform to the standards of Subsection 10-4-3.2.F, Neighborhood Conservation.
  • Table 10-3-2.2.1
    Residential Lot and Building Standards
    District and Housing TypeMaximum
    Density (Dwelling Units/Acre)4
    MinimumMaximum
    Building
    Height4
    LotSetbacksCommon Open Space
    Area1WidthFront2

    Interior Side2

    Corner2Rear3
    Single-Family Detached
    NC66,000 sf.50'5' / 20'5'5' / 10'20' / 20'--35'
    Single-Family Attached
    NC144,500 sf.40'5' / 20'0' / 5'5' / 10'20' / 20'--35'
    CM183,500 sf.30'0' / 8'0' / 5'5' / 10'10' / 20'--35'
    Multiplex
    NC222,000 sf.20'5' / 20'8'8' / 10'20' / 20'--35'
    CM261.500 sf.15'5' / 10'5'5' / 10'10' / 20'--45'
    Townhouse
    NC252,000 sf.20'15' / 25'0' / 8'12' / 25'20' / 20'20%35'
    CM311,250 sf.15'8' / 15'0' / 8'8' / 15'10' / 20'15%45'
    Multi-Family
    NC36----15' / 20'15'10' / 20'10' / 20'30%45'
    CM52 / 62 ----15' / 20'10'10' / 20'10' / 20'25%55 ' / 65'

    Table Notes:

    1. 1.
      Lot area is calculated on a per dwelling unit basis.
    2. 2.
      Where two setback dimensions are shown, the lesser dimension is for the build-to, shop front, and stoop frontage types, where permitted according to Section 10-3-3.2, CMU Standards of Design. The second dimension is the maximum setback.
    3. 3.
      The two dimensions shown are the rear yard setbacks when adjoining and not adjoining an alley, respectively.
    4. 4.
      The larger number represents the potential allowance with incentives from Section 10-1-3.4, Sustainable Building Design.
    Table 10-3-2.2.1
    Residential Lot and Building Standards
    District and Housing TypeMaximum
    Density (Dwelling Units/Acre)4
    MinimumMaximum
    Building
    Height4
    LotSetbacksCommon Open Space
    Area1WidthFront2

    Interior Side2

    Corner2Rear3
    Single-Family Detached
    NC66,000 sf.50'5' / 20'5'5' / 10'20' / 20'--35'
    Single-Family Attached
    NC144,500 sf.40'5' / 20'0' / 5'5' / 10'20' / 20'--35'
    CM183,500 sf.30'0' / 8'0' / 5'5' / 10'10' / 20'--35'
    Multiplex
    NC222,000 sf.20'5' / 20'8'8' / 10'20' / 20'--35'
    CM261.500 sf.15'5' / 10'5'5' / 10'10' / 20'--45'
    Townhouse
    NC252,000 sf.20'15' / 25'0' / 8'12' / 25'20' / 20'20%35'
    CM311,250 sf.15'8' / 15'0' / 8'8' / 15'10' / 20'15%45'
    Multi-Family
    NC36----15' / 20'15'10' / 20'10' / 20'30%45'
    CM52 / 62 ----15' / 20'10'10' / 20'10' / 20'25%55 ' / 65'

    Table Notes:

    1. 1.
      Lot area is calculated on a per dwelling unit basis.
    2. 2.
      Where two setback dimensions are shown, the lesser dimension is for the build-to, shop front, and stoop frontage types, where permitted according to Section 10-3-3.2, CMU Standards of Design. The second dimension is the maximum setback.
    3. 3.
      The two dimensions shown are the rear yard setbacks when adjoining and not adjoining an alley, respectively.
    4. 4.
      The larger number represents the potential allowance with incentives from Section 10-1-3.4, Sustainable Building Design.
    Table 10-3-2.2.1
    Residential Lot and Building Standards
    District and Housing TypeMaximum
    Density (Dwelling Units/Acre)4
    MinimumMaximum
    Building
    Height4
    LotSetbacksCommon Open Space
    Area1WidthFront2

    Interior Side2

    Corner2Rear3
    Single-Family Detached
    NC66,000 sf.50'5' / 20'5'5' / 10'20' / 20'--35'
    Single-Family Attached
    NC144,500 sf.40'5' / 20'0' / 5'5' / 10'20' / 20'--35'
    CM183,500 sf.30'0' / 8'0' / 5'5' / 10'10' / 20'--35'
    Multiplex
    NC222,000 sf.20'5' / 20'8'8' / 10'20' / 20'--35'
    CM261.500 sf.15'5' / 10'5'5' / 10'10' / 20'--45'
    Townhouse
    NC252,000 sf.20'15' / 25'0' / 8'12' / 25'20' / 20'20%35'
    CM311,250 sf.15'8' / 15'0' / 8'8' / 15'10' / 20'15%45'
    Multi-Family
    NC36----15' / 20'15'10' / 20'10' / 20'30%45'
    CM52 / 62 ----15' / 20'10'10' / 20'10' / 20'25%55 ' / 65'

    Table Notes:

    1. 1.
      Lot area is calculated on a per dwelling unit basis.
    2. 2.
      Where two setback dimensions are shown, the lesser dimension is for the build-to, shop front, and stoop frontage types, where permitted according to Section 10-3-3.2, CMU Standards of Design. The second dimension is the maximum setback.
    3. 3.
      The two dimensions shown are the rear yard setbacks when adjoining and not adjoining an alley, respectively.
    4. 4.
      The larger number represents the potential allowance with incentives from Section 10-1-3.4, Sustainable Building Design.
    Table 10-3-2.2.1
    Residential Lot and Building Standards
    District and Housing TypeMaximum
    Density (Dwelling Units/Acre)4
    MinimumMaximum
    Building
    Height4
    LotSetbacksCommon Open Space
    Area1WidthFront2

    Interior Side2

    Corner2Rear3
    Single-Family Detached
    NC66,000 sf.50'5' / 20'5'5' / 10'20' / 20'--35'
    Single-Family Attached
    NC144,500 sf.40'5' / 20'0' / 5'5' / 10'20' / 20'--35'
    CM183,500 sf.30'0' / 8'0' / 5'5' / 10'10' / 20'--35'
    Multiplex
    NC222,000 sf.20'5' / 20'8'8' / 10'20' / 20'--35'
    CM261.500 sf.15'5' / 10'5'5' / 10'10' / 20'--45'
    Townhouse
    NC252,000 sf.20'15' / 25'0' / 8'12' / 25'20' / 20'20%35'
    CM311,250 sf.15'8' / 15'0' / 8'8' / 15'10' / 20'15%45'
    Multi-Family
    NC36----15' / 20'15'10' / 20'10' / 20'30%45'
    CM52 / 62 ----15' / 20'10'10' / 20'10' / 20'25%55 ' / 65'

    Table Notes:

    1. 1.
      Lot area is calculated on a per dwelling unit basis.
    2. 2.
      Where two setback dimensions are shown, the lesser dimension is for the build-to, shop front, and stoop frontage types, where permitted according to Section 10-3-3.2, CMU Standards of Design. The second dimension is the maximum setback.
    3. 3.
      The two dimensions shown are the rear yard setbacks when adjoining and not adjoining an alley, respectively.
    4. 4.
      The larger number represents the potential allowance with incentives from Section 10-1-3.4, Sustainable Building Design.
    1.   
      1. 2.
        Non-Residential Lots and Mixed-Use Lot and Building Standards.
        1. a.

          The standards in Table 10-3-2.2.2, Non-Residential Lot and Mixed-Use Lot and Building Standards, apply to new development within the Neighborhood Commercial (NC) and Corridor Mixed (CM) districts.

        2. b.

          Construction or reconstruction of non-residential or mixed-use buildings within the NC and CM districts shall conform to the standards of this Section, subject to the provisions of Section 10-10-3.1, Administrative Compliance, or as applicable, Section 10-9-5.8, Adaptive Reuse Plan.

        3. c.

          Additions or expansions to existing buildings shall conform to the standards of this Section, subject to the provisions of Section 10-10-3.1, Administrative Compliance.

    Table 10-3-2.2.2 

    Non-Residential and Mixed-Use Lot and Building Standards

    District and Building TypeDensity (Dwelling Units / Acre)3MinimumMaximum
    Building
    Height3,4
    LotSetbacksCommon Open Space
    AreaWidthFront1

    Interior Side1

    Corner Lot1Rear2
    Live-Work
    NC9----10' / 20'8'8' / 12'15' / 20'20%44'
    CM10----5' / 15'0' / 8'5' / 10'10' / 20'15%47' / 58'
    Mixed-Use
    NC24 / 29----8' / 20'8'8' / 12'15' / 20'15%47' / 58'

    CM

    50 / 60----0' / 5'0' / 8'0' / 5'0' / 10'12%80' / 91'
    Commercial
    NC

    --

    ----8' / 20'8'8' / 12'15' / 20'18%47' / 58'
    CM------0' / 5'0' / 8'0' / 5'0' / 10'15%80' / 91'
    Office-Institutional
    NC

    --

    ----8' / 20'8'8' / 12'15' / 20'20%47' / 58'
    CM------0' / 15'0' / 8'0' / 12'0' / 10'15%80' / 91'

    Table Notes:

    1. 1.
      Where two setback dimensions are shown, the lesser dimension is for the build-to, shop front, and stoop frontage types, where permitted according to Section 10-3-3.2, CMU Standards of Design. The second dimension is the maximum build-to line in the front and the minimum setback for the side yard setback.
    2. 2.
      The two dimensions shown are rear yard setbacks when adjoining and not adjoining an alley, respectively.
    3. 3.
      Greater density or height may be permitted for development that meets the standards set out in Section 10-1-3.4,Sustainable Building Design. Increased height is subject to the bulk plane standards set out in Subsection 10-1-3.5, Transition Standards, when the CM district shares a common lot line with an ACR, LLR, MLR or SLR district. Development internal to a CM district is exempt from the bulk plane standards.
    4. 4.
      Height is based upon a maximum first floor height of 14 feet.

    Table 10-3-2.2.2 

    Non-Residential and Mixed-Use Lot and Building Standards

    District and Building TypeDensity (Dwelling Units / Acre)3MinimumMaximum
    Building
    Height3,4
    LotSetbacksCommon Open Space
    AreaWidthFront1

    Interior Side1

    Corner Lot1Rear2
    Live-Work
    NC9----10' / 20'8'8' / 12'15' / 20'20%44'
    CM10----5' / 15'0' / 8'5' / 10'10' / 20'15%47' / 58'
    Mixed-Use
    NC24 / 29----8' / 20'8'8' / 12'15' / 20'15%47' / 58'

    CM

    50 / 60----0' / 5'0' / 8'0' / 5'0' / 10'12%80' / 91'
    Commercial
    NC

    --

    ----8' / 20'8'8' / 12'15' / 20'18%47' / 58'
    CM------0' / 5'0' / 8'0' / 5'0' / 10'15%80' / 91'
    Office-Institutional
    NC

    --

    ----8' / 20'8'8' / 12'15' / 20'20%47' / 58'
    CM------0' / 15'0' / 8'0' / 12'0' / 10'15%80' / 91'

    Table Notes:

    1. 1.
      Where two setback dimensions are shown, the lesser dimension is for the build-to, shop front, and stoop frontage types, where permitted according to Section 10-3-3.2, CMU Standards of Design. The second dimension is the maximum build-to line in the front and the minimum setback for the side yard setback.
    2. 2.
      The two dimensions shown are rear yard setbacks when adjoining and not adjoining an alley, respectively.
    3. 3.
      Greater density or height may be permitted for development that meets the standards set out in Section 10-1-3.4,Sustainable Building Design. Increased height is subject to the bulk plane standards set out in Subsection 10-1-3.5, Transition Standards, when the CM district shares a common lot line with an ACR, LLR, MLR or SLR district. Development internal to a CM district is exempt from the bulk plane standards.
    4. 4.
      Height is based upon a maximum first floor height of 14 feet.

    Table 10-3-2.2.2 

    Non-Residential and Mixed-Use Lot and Building Standards

    District and Building TypeDensity (Dwelling Units / Acre)3MinimumMaximum
    Building
    Height3,4
    LotSetbacksCommon Open Space
    AreaWidthFront1

    Interior Side1

    Corner Lot1Rear2
    Live-Work
    NC9----10' / 20'8'8' / 12'15' / 20'20%44'
    CM10----5' / 15'0' / 8'5' / 10'10' / 20'15%47' / 58'
    Mixed-Use
    NC24 / 29----8' / 20'8'8' / 12'15' / 20'15%47' / 58'

    CM

    50 / 60----0' / 5'0' / 8'0' / 5'0' / 10'12%80' / 91'
    Commercial
    NC

    --

    ----8' / 20'8'8' / 12'15' / 20'18%47' / 58'
    CM------0' / 5'0' / 8'0' / 5'0' / 10'15%80' / 91'
    Office-Institutional
    NC

    --

    ----8' / 20'8'8' / 12'15' / 20'20%47' / 58'
    CM------0' / 15'0' / 8'0' / 12'0' / 10'15%80' / 91'

    Table Notes:

    1. 1.
      Where two setback dimensions are shown, the lesser dimension is for the build-to, shop front, and stoop frontage types, where permitted according to Section 10-3-3.2, CMU Standards of Design. The second dimension is the maximum build-to line in the front and the minimum setback for the side yard setback.
    2. 2.
      The two dimensions shown are rear yard setbacks when adjoining and not adjoining an alley, respectively.
    3. 3.
      Greater density or height may be permitted for development that meets the standards set out in Section 10-1-3.4,Sustainable Building Design. Increased height is subject to the bulk plane standards set out in Subsection 10-1-3.5, Transition Standards, when the CM district shares a common lot line with an ACR, LLR, MLR or SLR district. Development internal to a CM district is exempt from the bulk plane standards.
    4. 4.
      Height is based upon a maximum first floor height of 14 feet.

    Table 10-3-2.2.2 

    Non-Residential and Mixed-Use Lot and Building Standards

    District and Building TypeDensity (Dwelling Units / Acre)3MinimumMaximum
    Building
    Height3,4
    LotSetbacksCommon Open Space
    AreaWidthFront1

    Interior Side1

    Corner Lot1Rear2
    Live-Work
    NC9----10' / 20'8'8' / 12'15' / 20'20%44'
    CM10----5' / 15'0' / 8'5' / 10'10' / 20'15%47' / 58'
    Mixed-Use
    NC24 / 29----8' / 20'8'8' / 12'15' / 20'15%47' / 58'

    CM

    50 / 60----0' / 5'0' / 8'0' / 5'0' / 10'12%80' / 91'
    Commercial
    NC

    --

    ----8' / 20'8'8' / 12'15' / 20'18%47' / 58'
    CM------0' / 5'0' / 8'0' / 5'0' / 10'15%80' / 91'
    Office-Institutional
    NC

    --

    ----8' / 20'8'8' / 12'15' / 20'20%47' / 58'
    CM------0' / 15'0' / 8'0' / 12'0' / 10'15%80' / 91'

    Table Notes:

    1. 1.
      Where two setback dimensions are shown, the lesser dimension is for the build-to, shop front, and stoop frontage types, where permitted according to Section 10-3-3.2, CMU Standards of Design. The second dimension is the maximum build-to line in the front and the minimum setback for the side yard setback.
    2. 2.
      The two dimensions shown are rear yard setbacks when adjoining and not adjoining an alley, respectively.
    3. 3.
      Greater density or height may be permitted for development that meets the standards set out in Section 10-1-3.4,Sustainable Building Design. Increased height is subject to the bulk plane standards set out in Subsection 10-1-3.5, Transition Standards, when the CM district shares a common lot line with an ACR, LLR, MLR or SLR district. Development internal to a CM district is exempt from the bulk plane standards.
    4. 4.
      Height is based upon a maximum first floor height of 14 feet.

    (Ord. 18, Series of 2022; Ord. 20, Series of 2023) 

    Effective on: 10/13/2023

    Section 10-3-3.1 CMU Building Materials

  • A.
    Applicability. These building material standards apply to the Neighborhood Commercial (NC) and Corridor Mixed (CM) districts.
  • B.
    Building Materials.
    1. 1.
      Material Types. Refer to Subsection 10-1-3.2.A, Building Material Standards.
    2. 2.
      Building Materials Table. Displayed in Table 10-3-3.1, CMU Building and Roofing Materials, are the applicable zoning districts and the allowable material types.
    3. 3.
      Alternate Materials. Refer to Subsection 10-1-3.2.A, Building Material Standards.
  • Table 10-3-3.1

    CMU Building and Roofing Materials

    P = Primary material; S = Secondary material; "--" = Prohibited
    See Section 10-1-3.2.AMaterial TypeNeighborhood Commercial (NC)Corridor Mixed (CM)
    1 Masonry
    1a)Modular BrickP, SP, S
    1b)Modular StoneP, SP, S
    1c)Architectural cast or precast concrete (detailed)--P, S
    1d)Architectural reinforced concrete (glass fiber, fiber)--S
    1e)Cement board sidingP, SS
    1f)Terra cottaSP, S
    1g)Cast stoneP, SP, S
    1h)Architectural concrete masonry unitSS
    1i)Panelized brick or stoneSS
    --Cinder block--S
    --Plywood siding (T1-11)----
    --Unfired or underfired clay, sand, or shale brick----
    --Smooth or untextured concrete finishesSS
    2 Metal
    2a)Metal panels--S
    2b)Metal accentsSS
    3 Siding
    3a)Horizontal lap (wood, cement board)P2, SS1
    3b)Shingles (wood, cement board)P2, S--
    3c)Vertical board and batten (wood, cement board)--S
    --Galvanized, aluminum coated, zinc-aluminum coated or unpainted metal finishes--S
    --Corrugated metal, plastic, or fiberglass panels----
    --Vinyl siding----
    4 Stucco
    4a)AuthenticP, SP, S
    4b)Synthetic (scored)SS
    4c)Synthetic (not scored)SS
    5 Glass
    5a)Curtain wall--P
    5b)Glass accentSS
    --Glass blockPP
    6 Roof Materials
    6a)Asphalt shingles (architectural grade)PP2
    6b)Ceramic tilePP
    6b)Clay tilePP
    6b)Concrete tilePP
    --Aluminum shinglesPP
    --SlatePP
    6c)Standing seam metalSP
    Table Notes:
    1. 1.
      Only allowed on upper stories that are stepped back from the building front.
    2. 2.
      Residential structures only.

    Table 10-3-3.1

    CMU Building and Roofing Materials

    P = Primary material; S = Secondary material; "--" = Prohibited
    See Section 10-1-3.2.AMaterial TypeNeighborhood Commercial (NC)Corridor Mixed (CM)
    1 Masonry
    1a)Modular BrickP, SP, S
    1b)Modular StoneP, SP, S
    1c)Architectural cast or precast concrete (detailed)--P, S
    1d)Architectural reinforced concrete (glass fiber, fiber)--S
    1e)Cement board sidingP, SS
    1f)Terra cottaSP, S
    1g)Cast stoneP, SP, S
    1h)Architectural concrete masonry unitSS
    1i)Panelized brick or stoneSS
    --Cinder block--S
    --Plywood siding (T1-11)----
    --Unfired or underfired clay, sand, or shale brick----
    --Smooth or untextured concrete finishesSS
    2 Metal
    2a)Metal panels--S
    2b)Metal accentsSS
    3 Siding
    3a)Horizontal lap (wood, cement board)P2, SS1
    3b)Shingles (wood, cement board)P2, S--
    3c)Vertical board and batten (wood, cement board)--S
    --Galvanized, aluminum coated, zinc-aluminum coated or unpainted metal finishes--S
    --Corrugated metal, plastic, or fiberglass panels----
    --Vinyl siding----
    4 Stucco
    4a)AuthenticP, SP, S
    4b)Synthetic (scored)SS
    4c)Synthetic (not scored)SS
    5 Glass
    5a)Curtain wall--P
    5b)Glass accentSS
    --Glass blockPP
    6 Roof Materials
    6a)Asphalt shingles (architectural grade)PP2
    6b)Ceramic tilePP
    6b)Clay tilePP
    6b)Concrete tilePP
    --Aluminum shinglesPP
    --SlatePP
    6c)Standing seam metalSP
    Table Notes:
    1. 1.
      Only allowed on upper stories that are stepped back from the building front.
    2. 2.
      Residential structures only.

    Table 10-3-3.1

    CMU Building and Roofing Materials

    P = Primary material; S = Secondary material; "--" = Prohibited
    See Section 10-1-3.2.AMaterial TypeNeighborhood Commercial (NC)Corridor Mixed (CM)
    1 Masonry
    1a)Modular BrickP, SP, S
    1b)Modular StoneP, SP, S
    1c)Architectural cast or precast concrete (detailed)--P, S
    1d)Architectural reinforced concrete (glass fiber, fiber)--S
    1e)Cement board sidingP, SS
    1f)Terra cottaSP, S
    1g)Cast stoneP, SP, S
    1h)Architectural concrete masonry unitSS
    1i)Panelized brick or stoneSS
    --Cinder block--S
    --Plywood siding (T1-11)----
    --Unfired or underfired clay, sand, or shale brick----
    --Smooth or untextured concrete finishesSS
    2 Metal
    2a)Metal panels--S
    2b)Metal accentsSS
    3 Siding
    3a)Horizontal lap (wood, cement board)P2, SS1
    3b)Shingles (wood, cement board)P2, S--
    3c)Vertical board and batten (wood, cement board)--S
    --Galvanized, aluminum coated, zinc-aluminum coated or unpainted metal finishes--S
    --Corrugated metal, plastic, or fiberglass panels----
    --Vinyl siding----
    4 Stucco
    4a)AuthenticP, SP, S
    4b)Synthetic (scored)SS
    4c)Synthetic (not scored)SS
    5 Glass
    5a)Curtain wall--P
    5b)Glass accentSS
    --Glass blockPP
    6 Roof Materials
    6a)Asphalt shingles (architectural grade)PP2
    6b)Ceramic tilePP
    6b)Clay tilePP
    6b)Concrete tilePP
    --Aluminum shinglesPP
    --SlatePP
    6c)Standing seam metalSP
    Table Notes:
    1. 1.
      Only allowed on upper stories that are stepped back from the building front.
    2. 2.
      Residential structures only.

    Table 10-3-3.1

    CMU Building and Roofing Materials

    P = Primary material; S = Secondary material; "--" = Prohibited
    See Section 10-1-3.2.AMaterial TypeNeighborhood Commercial (NC)Corridor Mixed (CM)
    1 Masonry
    1a)Modular BrickP, SP, S
    1b)Modular StoneP, SP, S
    1c)Architectural cast or precast concrete (detailed)--P, S
    1d)Architectural reinforced concrete (glass fiber, fiber)--S
    1e)Cement board sidingP, SS
    1f)Terra cottaSP, S
    1g)Cast stoneP, SP, S
    1h)Architectural concrete masonry unitSS
    1i)Panelized brick or stoneSS
    --Cinder block--S
    --Plywood siding (T1-11)----
    --Unfired or underfired clay, sand, or shale brick----
    --Smooth or untextured concrete finishesSS
    2 Metal
    2a)Metal panels--S
    2b)Metal accentsSS
    3 Siding
    3a)Horizontal lap (wood, cement board)P2, SS1
    3b)Shingles (wood, cement board)P2, S--
    3c)Vertical board and batten (wood, cement board)--S
    --Galvanized, aluminum coated, zinc-aluminum coated or unpainted metal finishes--S
    --Corrugated metal, plastic, or fiberglass panels----
    --Vinyl siding----
    4 Stucco
    4a)AuthenticP, SP, S
    4b)Synthetic (scored)SS
    4c)Synthetic (not scored)SS
    5 Glass
    5a)Curtain wall--P
    5b)Glass accentSS
    --Glass blockPP
    6 Roof Materials
    6a)Asphalt shingles (architectural grade)PP2
    6b)Ceramic tilePP
    6b)Clay tilePP
    6b)Concrete tilePP
    --Aluminum shinglesPP
    --SlatePP
    6c)Standing seam metalSP
    Table Notes:
    1. 1.
      Only allowed on upper stories that are stepped back from the building front.
    2. 2.
      Residential structures only.

    Effective on: 10/28/2021

    Section 10-3-3.2 CMU Standards of Design

  • A.
    Purpose. The purpose of this Section is to provide site and building design and street frontage standards for the NC and CM districts. Where impractical, these provisions may be subject to waiver requests at the sole discretion of the Director.
  • B.
    Applicability. The standards of this Section apply to:
    1. 1.
      New. New non-residential and mixed-use principal buildings;
    2. 2.
      Minor Additions or Alterations. Added or altered portions of an existing non-residential and mixed-use principal building; and
    3. 3.
      Major Additions or Alterations. Added or altered portions of an existing non-residential and mixed-use principal building when the addition or alteration exceeds 25 percent of the building’s existing gross floor area.
      1. Section 10-3-4.1 CMU Landscaping

      2. A.

        Purpose. To provide landscape design standards specific to commercial and mixed-use development in NC and CM districts.

      3. B.

        Applicability. All new development, redevelopment, and adaptive reuse in the NC and CM districts shall comply with this Section, together with the standards in Section 10-1-3.6, Greenscape Design Standards. Where impractical, these provisions may be subject to waiver requests at the sole discretion of the Director.

      4. C.
        Minimum Planting Standards.
        1. 1.
          Site Landscaping. The minimum landscape plantings required within the NC and CM districts are set out in Table 10-3-4.1, CMU Minimum Landscape Planting Requirements.
        2. 2.
          Canopy Coverage. The tree canopy coverage requirements for the NC and CM districts are set out in Subsection 10-1-3.6.E, Tree Canopy Coverage Requirements.
        3. 3.
          Adjustments. On sites where there are physical constraints to meeting the minimum landscape requirements of this Section due to frontage type or other site-specific conditions, the Director may authorize an adjustment as set out in Section 10-9-9.1, Administrative Adjustment.
      5.  Table 10-3-4.1

        CMU Minimum Landscape Planting Requirements

        District

        Tree and Shrub PlantingsParking Lot Landscaping1,2Common Open Space Landscaping3
        NC, Neighborhood Commercial

        Street Trees:

        deciduous tree per 40' linear street frontage.

         

        Understory Plantings: Shrubs and grasses along 75% of all street-facing building elevations, at least 2' from the foundation.

        Perimeter Screening: Shrubs shall be planted along 75% of all parking and vehicular use areas that are parallel, or approximately parallel, to public street rights-of-way.  Shrubs shall be planted along 50% of a common boundary between parking lots.

         

        Interior Landscaping: Landscape islands shall cover a minimum of 5% of parking and vehicular use area surfaces. Each island shall include 1 deciduous tree, 50% coverage in shrubs, and the remaining in groundcover.

        Pervious Area: 1 deciduous or two evergreen trees per 500 sf.
        CM, Corridor Mixed

        Street Trees:

        deciduous tree per 40' of linear frontage.

         

        Understory Plantings: Shrubs and grasses extending along 50% of all building elevations facing a street or parking lot of an adjoining property, placed at least 2' from the foundation.

        Perimeter Screening: Shrubs shall be planted along 100% of all parking and vehicular use areas that are parallel, or approximately parallel, to public street rights-of-way.  Shrubs shall be planted along 75% of a common boundary between parking lots.

         

        Interior Landscaping: Landscape islands shall cover a minimum of 5% of parking and vehicular use area surfaces. Each island shall include 1 deciduous tree and 100% coverage in shrubs.

        Pervious Area: 1 deciduous or two evergreen trees per 1,000 sf.

        Table Notes:

        1. 1.
          A landscape island measures a minimum of 162 sf. (9' X 18').
        2. 2.
          Parking lot landscaping is not required in a rear or interior side yard without frontage on a street, adjacent drive, or parking lot.
        3. 3.
          Common open space landscaping excludes all areas established to meet street tree and understory plantings, parking lot landscaping, and bufferyard requirements.

         Table 10-3-4.1

        CMU Minimum Landscape Planting Requirements

        District

        Tree and Shrub PlantingsParking Lot Landscaping1,2Common Open Space Landscaping3
        NC, Neighborhood Commercial

        Street Trees:

        deciduous tree per 40' linear street frontage.

         

        Understory Plantings: Shrubs and grasses along 75% of all street-facing building elevations, at least 2' from the foundation.

        Perimeter Screening: Shrubs shall be planted along 75% of all parking and vehicular use areas that are parallel, or approximately parallel, to public street rights-of-way.  Shrubs shall be planted along 50% of a common boundary between parking lots.

         

        Interior Landscaping: Landscape islands shall cover a minimum of 5% of parking and vehicular use area surfaces. Each island shall include 1 deciduous tree, 50% coverage in shrubs, and the remaining in groundcover.

        Pervious Area: 1 deciduous or two evergreen trees per 500 sf.
        CM, Corridor Mixed

        Street Trees:

        deciduous tree per 40' of linear frontage.

         

        Understory Plantings: Shrubs and grasses extending along 50% of all building elevations facing a street or parking lot of an adjoining property, placed at least 2' from the foundation.

        Perimeter Screening: Shrubs shall be planted along 100% of all parking and vehicular use areas that are parallel, or approximately parallel, to public street rights-of-way.  Shrubs shall be planted along 75% of a common boundary between parking lots.

         

        Interior Landscaping: Landscape islands shall cover a minimum of 5% of parking and vehicular use area surfaces. Each island shall include 1 deciduous tree and 100% coverage in shrubs.

        Pervious Area: 1 deciduous or two evergreen trees per 1,000 sf.

        Table Notes:

        1. 1.
          A landscape island measures a minimum of 162 sf. (9' X 18').
        2. 2.
          Parking lot landscaping is not required in a rear or interior side yard without frontage on a street, adjacent drive, or parking lot.
        3. 3.
          Common open space landscaping excludes all areas established to meet street tree and understory plantings, parking lot landscaping, and bufferyard requirements.

         Table 10-3-4.1

        CMU Minimum Landscape Planting Requirements

        District

        Tree and Shrub PlantingsParking Lot Landscaping1,2Common Open Space Landscaping3
        NC, Neighborhood Commercial

        Street Trees:

        deciduous tree per 40' linear street frontage.

         

        Understory Plantings: Shrubs and grasses along 75% of all street-facing building elevations, at least 2' from the foundation.

        Perimeter Screening: Shrubs shall be planted along 75% of all parking and vehicular use areas that are parallel, or approximately parallel, to public street rights-of-way.  Shrubs shall be planted along 50% of a common boundary between parking lots.

         

        Interior Landscaping: Landscape islands shall cover a minimum of 5% of parking and vehicular use area surfaces. Each island shall include 1 deciduous tree, 50% coverage in shrubs, and the remaining in groundcover.

        Pervious Area: 1 deciduous or two evergreen trees per 500 sf.
        CM, Corridor Mixed

        Street Trees:

        deciduous tree per 40' of linear frontage.

         

        Understory Plantings: Shrubs and grasses extending along 50% of all building elevations facing a street or parking lot of an adjoining property, placed at least 2' from the foundation.

        Perimeter Screening: Shrubs shall be planted along 100% of all parking and vehicular use areas that are parallel, or approximately parallel, to public street rights-of-way.  Shrubs shall be planted along 75% of a common boundary between parking lots.

         

        Interior Landscaping: Landscape islands shall cover a minimum of 5% of parking and vehicular use area surfaces. Each island shall include 1 deciduous tree and 100% coverage in shrubs.

        Pervious Area: 1 deciduous or two evergreen trees per 1,000 sf.

        Table Notes:

        1. 1.
          A landscape island measures a minimum of 162 sf. (9' X 18').
        2. 2.
          Parking lot landscaping is not required in a rear or interior side yard without frontage on a street, adjacent drive, or parking lot.
        3. 3.
          Common open space landscaping excludes all areas established to meet street tree and understory plantings, parking lot landscaping, and bufferyard requirements.

         Table 10-3-4.1

        CMU Minimum Landscape Planting Requirements

        District

        Tree and Shrub PlantingsParking Lot Landscaping1,2Common Open Space Landscaping3
        NC, Neighborhood Commercial

        Street Trees:

        deciduous tree per 40' linear street frontage.

         

        Understory Plantings: Shrubs and grasses along 75% of all street-facing building elevations, at least 2' from the foundation.

        Perimeter Screening: Shrubs shall be planted along 75% of all parking and vehicular use areas that are parallel, or approximately parallel, to public street rights-of-way.  Shrubs shall be planted along 50% of a common boundary between parking lots.

         

        Interior Landscaping: Landscape islands shall cover a minimum of 5% of parking and vehicular use area surfaces. Each island shall include 1 deciduous tree, 50% coverage in shrubs, and the remaining in groundcover.

        Pervious Area: 1 deciduous or two evergreen trees per 500 sf.
        CM, Corridor Mixed

        Street Trees:

        deciduous tree per 40' of linear frontage.

         

        Understory Plantings: Shrubs and grasses extending along 50% of all building elevations facing a street or parking lot of an adjoining property, placed at least 2' from the foundation.

        Perimeter Screening: Shrubs shall be planted along 100% of all parking and vehicular use areas that are parallel, or approximately parallel, to public street rights-of-way.  Shrubs shall be planted along 75% of a common boundary between parking lots.

         

        Interior Landscaping: Landscape islands shall cover a minimum of 5% of parking and vehicular use area surfaces. Each island shall include 1 deciduous tree and 100% coverage in shrubs.

        Pervious Area: 1 deciduous or two evergreen trees per 1,000 sf.

        Table Notes:

        1. 1.
          A landscape island measures a minimum of 162 sf. (9' X 18').
        2. 2.
          Parking lot landscaping is not required in a rear or interior side yard without frontage on a street, adjacent drive, or parking lot.
        3. 3.
          Common open space landscaping excludes all areas established to meet street tree and understory plantings, parking lot landscaping, and bufferyard requirements.

        Effective on: 10/28/2021

        Section 10-3-4.2 CMU Bufferyards

        Refer to Subsection 10-1-3.6.F, Bufferyard Requirements, for provisions related to the district bufferyards and where they are required or exempted.

        Effective on: 10/28/2021

        Section 10-3-5.1 CMU Sign Types and Standards

      6. A.
        Applicability. The sign requirements in this Section apply to the NC and CM districts.
      7. B.
        Master Sign Plan. Refer to Subsec. 10-1-3.10.G.
      8. C.
        Sign Types.
        1. 1.
          Unlisted Sign Types. Sign types that are not listed in the following tables are prohibited in these districts.
      9. Table 10-3-5.1.1

        CMU Sign Types

        P = Permitted;     "--" = Prohibited
        Sign TypesNeighborhood Commercial (NC)Commercial Mixed (CM)
        Attached Signs
        Arcade Sign--P
        Awning SignPP
        Blade SignPP
        Marquee Sign--P
        Projecting SignPP
        Wall SignPP
        Window SignPP
        Freestanding Signs
        Monument SignPP
        Pole Sign--P
        Post SignP--
        Pylon Sign--P
        Temporary Signs - See Subsection 10-1-3.10.F, Temporary Signs

        Table 10-3-5.1.1

        CMU Sign Types

        P = Permitted;     "--" = Prohibited
        Sign TypesNeighborhood Commercial (NC)Commercial Mixed (CM)
        Attached Signs
        Arcade Sign--P
        Awning SignPP
        Blade SignPP
        Marquee Sign--P
        Projecting SignPP
        Wall SignPP
        Window SignPP
        Freestanding Signs
        Monument SignPP
        Pole Sign--P
        Post SignP--
        Pylon Sign--P
        Temporary Signs - See Subsection 10-1-3.10.F, Temporary Signs

        Table 10-3-5.1.1

        CMU Sign Types

        P = Permitted;     "--" = Prohibited
        Sign TypesNeighborhood Commercial (NC)Commercial Mixed (CM)
        Attached Signs
        Arcade Sign--P
        Awning SignPP
        Blade SignPP
        Marquee Sign--P
        Projecting SignPP
        Wall SignPP
        Window SignPP
        Freestanding Signs
        Monument SignPP
        Pole Sign--P
        Post SignP--
        Pylon Sign--P
        Temporary Signs - See Subsection 10-1-3.10.F, Temporary Signs

        Table 10-3-5.1.1

        CMU Sign Types

        P = Permitted;     "--" = Prohibited
        Sign TypesNeighborhood Commercial (NC)Commercial Mixed (CM)
        Attached Signs
        Arcade Sign--P
        Awning SignPP
        Blade SignPP
        Marquee Sign--P
        Projecting SignPP
        Wall SignPP
        Window SignPP
        Freestanding Signs
        Monument SignPP
        Pole Sign--P
        Post SignP--
        Pylon Sign--P
        Temporary Signs - See Subsection 10-1-3.10.F, Temporary Signs
        1. D.
          Attached Signs. Set out in Table 10-3-5.1.2, CMU Attached Sign Standards, are the types, numbers, areas, heights, and methods of illumination allowed for each sign type and district.

        Table 10-3-5.1.2

        CMU Attached Sign Standards

        Sign Types / StandardsNeighborhood Commercial (NC)Corridor Mixed (CM)
        Arcade Sign
        Number Allowed--1 per public entrance under arcade
        Maximum Area--6 sq. ft.
        Minimum Clearance above Sidewalk--8 ft.
        Illumination--External downlighting or halo
        Changeable Copy----
        Awning or Canopy Sign
        Number Allowed1 per street-facing façade1 per building façade or 1 per storefront for a mixed-use or multi-tenant building
        Maximum Area6 sq. ft. with a vertical dimension of 1 ft.
        Minimum Vertical Clearance / Maximum Height Above GradeMinimum 8 ft. / Maximum no higher than top of ground floor4
        IlluminationExternal downlighting
        Changeable Copy--
        Blade Sign
        Number Allowed1 per each 10 ft. of an awning or canopy1 per each 8 ft. of an awning or canopy
        Maximum Area3 sq. ft. per face; 12 sq. ft. per sign8 sq. ft. per face; 16 sq. ft. per sign
        Minimum Vertical Clearance / Maximum Height Above Grade8 ft.8 ft.
        Illumination--External downlighting
        Changeable Copy----
        Marquee Sign
        Number Allowed--1 per front building façade
        Maximum Area1--32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear foot of building front width, whichever is greatest
        Min. / Max. Clearance Above Grade--12 ft. / 25 ft.
        Maximum Distance from Building Façade--48 inches4
        Illumination--Internal or halo
        Changeable Copy--Permitted
        Projecting Sign
        Number Allowed1 per street-facing façade1 per tenant per building frontage
        Maximum Area18 sq. ft. per face; 36 sq. ft. per sign
        Min.  /Max. Clearance Above Grade8 ft. / No higher than the ground floor
        Maximum Projection from Wall6 ft.; 3 ft. into right-of-way (subject to an encroachment permit)
        IlluminationInternal, halo, or downlight
        Changeable Copy--
        Wall Sign
        Number Allowed1 per street-facing façade31 per tenant per building frontage
        Maximum Area/Sign232 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of façade width occupied by an individual business, whichever is greatest
        Max. Clearance Above GradeNo higher than wall structure
        Maximum Projection from Wall12 in.4
        IlluminationExternal downlighting, internal, or halo
        Changeable Copy--
        Window Sign
        Number Allowed1 per tenant per building frontage1 per tenant per building frontage
        Maximum Area15% of combined area of all windows20% of combined area of all windows
        Max. Clearance Above Grade--No higher than top of ground floor
        IlluminationDimmable and any applicable standards in Sec. 

        10-1-3.11, Outdoor Lighting Standards 

        Dimmable and any applicable standards in Sec. 

        10-1-3.11, Outdoor Lighting Standards

        Changeable Copy--Permitted

        Table Notes:

        1. 1.
          Reserved.
        2. 2.
          The area of wall signs may be increased by 25 percent for each 10 ft. of building height above 30 ft. up to a maximum of 200 sq. ft. per sign.
        3. 3.
          Signs may be permitted on side and rear walls facing private streets or public right-of-way where there are no primary identification signs in the same line of sight.  
        4. 4.
          Awnings, canopies, marquees, and signs with less than 15 feet clearance above the sidewalk must meet building codes for maximum projection. 

        Table 10-3-5.1.2

        CMU Attached Sign Standards

        Sign Types / StandardsNeighborhood Commercial (NC)Corridor Mixed (CM)
        Arcade Sign
        Number Allowed--1 per public entrance under arcade
        Maximum Area--6 sq. ft.
        Minimum Clearance above Sidewalk--8 ft.
        Illumination--External downlighting or halo
        Changeable Copy----
        Awning or Canopy Sign
        Number Allowed1 per street-facing façade1 per building façade or 1 per storefront for a mixed-use or multi-tenant building
        Maximum Area6 sq. ft. with a vertical dimension of 1 ft.
        Minimum Vertical Clearance / Maximum Height Above GradeMinimum 8 ft. / Maximum no higher than top of ground floor4
        IlluminationExternal downlighting
        Changeable Copy--
        Blade Sign
        Number Allowed1 per each 10 ft. of an awning or canopy1 per each 8 ft. of an awning or canopy
        Maximum Area3 sq. ft. per face; 12 sq. ft. per sign8 sq. ft. per face; 16 sq. ft. per sign
        Minimum Vertical Clearance / Maximum Height Above Grade8 ft.8 ft.
        Illumination--External downlighting
        Changeable Copy----
        Marquee Sign
        Number Allowed--1 per front building façade
        Maximum Area1--32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear foot of building front width, whichever is greatest
        Min. / Max. Clearance Above Grade--12 ft. / 25 ft.
        Maximum Distance from Building Façade--48 inches4
        Illumination--Internal or halo
        Changeable Copy--Permitted
        Projecting Sign
        Number Allowed1 per street-facing façade1 per tenant per building frontage
        Maximum Area18 sq. ft. per face; 36 sq. ft. per sign
        Min.  /Max. Clearance Above Grade8 ft. / No higher than the ground floor
        Maximum Projection from Wall6 ft.; 3 ft. into right-of-way (subject to an encroachment permit)
        IlluminationInternal, halo, or downlight
        Changeable Copy--
        Wall Sign
        Number Allowed1 per street-facing façade31 per tenant per building frontage
        Maximum Area/Sign232 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of façade width occupied by an individual business, whichever is greatest
        Max. Clearance Above GradeNo higher than wall structure
        Maximum Projection from Wall12 in.4
        IlluminationExternal downlighting, internal, or halo
        Changeable Copy--
        Window Sign
        Number Allowed1 per tenant per building frontage1 per tenant per building frontage
        Maximum Area15% of combined area of all windows20% of combined area of all windows
        Max. Clearance Above Grade--No higher than top of ground floor
        IlluminationDimmable and any applicable standards in Sec. 

        10-1-3.11, Outdoor Lighting Standards 

        Dimmable and any applicable standards in Sec. 

        10-1-3.11, Outdoor Lighting Standards

        Changeable Copy--Permitted

        Table Notes:

        1. 1.
          Reserved.
        2. 2.
          The area of wall signs may be increased by 25 percent for each 10 ft. of building height above 30 ft. up to a maximum of 200 sq. ft. per sign.
        3. 3.
          Signs may be permitted on side and rear walls facing private streets or public right-of-way where there are no primary identification signs in the same line of sight.  
        4. 4.
          Awnings, canopies, marquees, and signs with less than 15 feet clearance above the sidewalk must meet building codes for maximum projection. 

        Table 10-3-5.1.2

        CMU Attached Sign Standards

        Sign Types / StandardsNeighborhood Commercial (NC)Corridor Mixed (CM)
        Arcade Sign
        Number Allowed--1 per public entrance under arcade
        Maximum Area--6 sq. ft.
        Minimum Clearance above Sidewalk--8 ft.
        Illumination--External downlighting or halo
        Changeable Copy----
        Awning or Canopy Sign
        Number Allowed1 per street-facing façade1 per building façade or 1 per storefront for a mixed-use or multi-tenant building
        Maximum Area6 sq. ft. with a vertical dimension of 1 ft.
        Minimum Vertical Clearance / Maximum Height Above GradeMinimum 8 ft. / Maximum no higher than top of ground floor4
        IlluminationExternal downlighting
        Changeable Copy--
        Blade Sign
        Number Allowed1 per each 10 ft. of an awning or canopy1 per each 8 ft. of an awning or canopy
        Maximum Area3 sq. ft. per face; 12 sq. ft. per sign8 sq. ft. per face; 16 sq. ft. per sign
        Minimum Vertical Clearance / Maximum Height Above Grade8 ft.8 ft.
        Illumination--External downlighting
        Changeable Copy----
        Marquee Sign
        Number Allowed--1 per front building façade
        Maximum Area1--32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear foot of building front width, whichever is greatest
        Min. / Max. Clearance Above Grade--12 ft. / 25 ft.
        Maximum Distance from Building Façade--48 inches4
        Illumination--Internal or halo
        Changeable Copy--Permitted
        Projecting Sign
        Number Allowed1 per street-facing façade1 per tenant per building frontage
        Maximum Area18 sq. ft. per face; 36 sq. ft. per sign
        Min.  /Max. Clearance Above Grade8 ft. / No higher than the ground floor
        Maximum Projection from Wall6 ft.; 3 ft. into right-of-way (subject to an encroachment permit)
        IlluminationInternal, halo, or downlight
        Changeable Copy--
        Wall Sign
        Number Allowed1 per street-facing façade31 per tenant per building frontage
        Maximum Area/Sign232 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of façade width occupied by an individual business, whichever is greatest
        Max. Clearance Above GradeNo higher than wall structure
        Maximum Projection from Wall12 in.4
        IlluminationExternal downlighting, internal, or halo
        Changeable Copy--
        Window Sign
        Number Allowed1 per tenant per building frontage1 per tenant per building frontage
        Maximum Area15% of combined area of all windows20% of combined area of all windows
        Max. Clearance Above Grade--No higher than top of ground floor
        IlluminationDimmable and any applicable standards in Sec. 

        10-1-3.11, Outdoor Lighting Standards 

        Dimmable and any applicable standards in Sec. 

        10-1-3.11, Outdoor Lighting Standards

        Changeable Copy--Permitted

        Table Notes:

        1. 1.
          Reserved.
        2. 2.
          The area of wall signs may be increased by 25 percent for each 10 ft. of building height above 30 ft. up to a maximum of 200 sq. ft. per sign.
        3. 3.
          Signs may be permitted on side and rear walls facing private streets or public right-of-way where there are no primary identification signs in the same line of sight.  
        4. 4.
          Awnings, canopies, marquees, and signs with less than 15 feet clearance above the sidewalk must meet building codes for maximum projection. 

        Table 10-3-5.1.2

        CMU Attached Sign Standards

        Sign Types / StandardsNeighborhood Commercial (NC)Corridor Mixed (CM)
        Arcade Sign
        Number Allowed--1 per public entrance under arcade
        Maximum Area--6 sq. ft.
        Minimum Clearance above Sidewalk--8 ft.
        Illumination--External downlighting or halo
        Changeable Copy----
        Awning or Canopy Sign
        Number Allowed1 per street-facing façade1 per building façade or 1 per storefront for a mixed-use or multi-tenant building
        Maximum Area6 sq. ft. with a vertical dimension of 1 ft.
        Minimum Vertical Clearance / Maximum Height Above GradeMinimum 8 ft. / Maximum no higher than top of ground floor4
        IlluminationExternal downlighting
        Changeable Copy--
        Blade Sign
        Number Allowed1 per each 10 ft. of an awning or canopy1 per each 8 ft. of an awning or canopy
        Maximum Area3 sq. ft. per face; 12 sq. ft. per sign8 sq. ft. per face; 16 sq. ft. per sign
        Minimum Vertical Clearance / Maximum Height Above Grade8 ft.8 ft.
        Illumination--External downlighting
        Changeable Copy----
        Marquee Sign
        Number Allowed--1 per front building façade
        Maximum Area1--32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear foot of building front width, whichever is greatest
        Min. / Max. Clearance Above Grade--12 ft. / 25 ft.
        Maximum Distance from Building Façade--48 inches4
        Illumination--Internal or halo
        Changeable Copy--Permitted
        Projecting Sign
        Number Allowed1 per street-facing façade1 per tenant per building frontage
        Maximum Area18 sq. ft. per face; 36 sq. ft. per sign
        Min.  /Max. Clearance Above Grade8 ft. / No higher than the ground floor
        Maximum Projection from Wall6 ft.; 3 ft. into right-of-way (subject to an encroachment permit)
        IlluminationInternal, halo, or downlight
        Changeable Copy--
        Wall Sign
        Number Allowed1 per street-facing façade31 per tenant per building frontage
        Maximum Area/Sign232 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of façade width occupied by an individual business, whichever is greatest
        Max. Clearance Above GradeNo higher than wall structure
        Maximum Projection from Wall12 in.4
        IlluminationExternal downlighting, internal, or halo
        Changeable Copy--
        Window Sign
        Number Allowed1 per tenant per building frontage1 per tenant per building frontage
        Maximum Area15% of combined area of all windows20% of combined area of all windows
        Max. Clearance Above Grade--No higher than top of ground floor
        IlluminationDimmable and any applicable standards in Sec. 

        10-1-3.11, Outdoor Lighting Standards 

        Dimmable and any applicable standards in Sec. 

        10-1-3.11, Outdoor Lighting Standards

        Changeable Copy--Permitted

        Table Notes:

        1. 1.
          Reserved.
        2. 2.
          The area of wall signs may be increased by 25 percent for each 10 ft. of building height above 30 ft. up to a maximum of 200 sq. ft. per sign.
        3. 3.
          Signs may be permitted on side and rear walls facing private streets or public right-of-way where there are no primary identification signs in the same line of sight.  
        4. 4.
          Awnings, canopies, marquees, and signs with less than 15 feet clearance above the sidewalk must meet building codes for maximum projection. 
        1. E.
          Freestanding Signs. Set out in Table 10-3-5.1.3, CMU Freestanding Sign Standards, are the types, numbers, areas, heights, and methods of illumination allowed for each sign type and district.

        Table 10-3-5.1.3

        CMU Freestanding Sign Standards

        Sign Types / StandardsNCCM
        Monument1
        Number Allowed1 per street frontage
        1. 1
          per 150 ft. of street frontage
        Maximum Area232 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width,  whichever is greater
        Maximum Height Above Grade6 ft.15 ft.
        Minimum Front Property Line Setback5 ft.5 ft.
        IlluminationInternally lit, Halo lit, or Externally downlit
        Changeable CopyPermitted2
        Bonus Sign Area--Yes; See Subsec. 10-1-3.10.E, Sign References and Bonuses
        Pole
        Number Allowed--1 per street frontage
        Maximum Area--32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width,  whichever is greater
        Maximum Height Above Grade--Lesser of the highest point of the building or 15 ft.
        Minimum Front Property Line Setback --5 ft.
        Bonus Sign Area--Yes; See Subsec. 10-1-3.10.E, Sign References and Bonuses
        Post Sign
        Number Allowed1 per street frontage
        Maximum Area6 sq. ft.
        Maximum Height Above Grade5 ft.
        Minimum Front Property Line Setback5 ft.
        Bonus Sign Area--
        Pylon1
        Number Allowed--1 per 150 ft. of street frontage
        Maximum Area2--32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width,  whichever is greater
        Maximum Height Above Grade--Lesser of the highest point of the building or 25 ft.
        Illumination--Internally lit, Halo lit, or Externally downlit
        Changeable Copy--Not Permitted
        Bonus Sign Area--Yes; See Subsec. 10-1-3.10.E, Sign References and Bonuses

        Table Notes:

        1. 1.
          A joint identification sign is permitted.
        2. 2.
          The maximum total area per sign allowed is 80 square feet per display face and 160 square feet per sign.

        Table 10-3-5.1.3

        CMU Freestanding Sign Standards

        Sign Types / StandardsNCCM
        Monument1
        Number Allowed1 per street frontage
        1. 1
          per 150 ft. of street frontage
        Maximum Area232 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width,  whichever is greater
        Maximum Height Above Grade6 ft.15 ft.
        Minimum Front Property Line Setback5 ft.5 ft.
        IlluminationInternally lit, Halo lit, or Externally downlit
        Changeable CopyPermitted2
        Bonus Sign Area--Yes; See Subsec. 10-1-3.10.E, Sign References and Bonuses
        Pole
        Number Allowed--1 per street frontage
        Maximum Area--32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width,  whichever is greater
        Maximum Height Above Grade--Lesser of the highest point of the building or 15 ft.
        Minimum Front Property Line Setback --5 ft.
        Bonus Sign Area--Yes; See Subsec. 10-1-3.10.E, Sign References and Bonuses
        Post Sign
        Number Allowed1 per street frontage
        Maximum Area6 sq. ft.
        Maximum Height Above Grade5 ft.
        Minimum Front Property Line Setback5 ft.
        Bonus Sign Area--
        Pylon1
        Number Allowed--1 per 150 ft. of street frontage
        Maximum Area2--32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width,  whichever is greater
        Maximum Height Above Grade--Lesser of the highest point of the building or 25 ft.
        Illumination--Internally lit, Halo lit, or Externally downlit
        Changeable Copy--Not Permitted
        Bonus Sign Area--Yes; See Subsec. 10-1-3.10.E, Sign References and Bonuses

        Table Notes:

        1. 1.
          A joint identification sign is permitted.
        2. 2.
          The maximum total area per sign allowed is 80 square feet per display face and 160 square feet per sign.

        Table 10-3-5.1.3

        CMU Freestanding Sign Standards

        Sign Types / StandardsNCCM
        Monument1
        Number Allowed1 per street frontage
        1. 1
          per 150 ft. of street frontage
        Maximum Area232 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width,  whichever is greater
        Maximum Height Above Grade6 ft.15 ft.
        Minimum Front Property Line Setback5 ft.5 ft.
        IlluminationInternally lit, Halo lit, or Externally downlit
        Changeable CopyPermitted2
        Bonus Sign Area--Yes; See Subsec. 10-1-3.10.E, Sign References and Bonuses
        Pole
        Number Allowed--1 per street frontage
        Maximum Area--32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width,  whichever is greater
        Maximum Height Above Grade--Lesser of the highest point of the building or 15 ft.
        Minimum Front Property Line Setback --5 ft.
        Bonus Sign Area--Yes; See Subsec. 10-1-3.10.E, Sign References and Bonuses
        Post Sign
        Number Allowed1 per street frontage
        Maximum Area6 sq. ft.
        Maximum Height Above Grade5 ft.
        Minimum Front Property Line Setback5 ft.
        Bonus Sign Area--
        Pylon1
        Number Allowed--1 per 150 ft. of street frontage
        Maximum Area2--32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width,  whichever is greater
        Maximum Height Above Grade--Lesser of the highest point of the building or 25 ft.
        Illumination--Internally lit, Halo lit, or Externally downlit
        Changeable Copy--Not Permitted
        Bonus Sign Area--Yes; See Subsec. 10-1-3.10.E, Sign References and Bonuses

        Table Notes:

        1. 1.
          A joint identification sign is permitted.
        2. 2.
          The maximum total area per sign allowed is 80 square feet per display face and 160 square feet per sign.

        Table 10-3-5.1.3

        CMU Freestanding Sign Standards

        Sign Types / StandardsNCCM
        Monument1
        Number Allowed1 per street frontage
        1. 1
          per 150 ft. of street frontage
        Maximum Area232 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width,  whichever is greater
        Maximum Height Above Grade6 ft.15 ft.
        Minimum Front Property Line Setback5 ft.5 ft.
        IlluminationInternally lit, Halo lit, or Externally downlit
        Changeable CopyPermitted2
        Bonus Sign Area--Yes; See Subsec. 10-1-3.10.E, Sign References and Bonuses
        Pole
        Number Allowed--1 per street frontage
        Maximum Area--32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width,  whichever is greater
        Maximum Height Above Grade--Lesser of the highest point of the building or 15 ft.
        Minimum Front Property Line Setback --5 ft.
        Bonus Sign Area--Yes; See Subsec. 10-1-3.10.E, Sign References and Bonuses
        Post Sign
        Number Allowed1 per street frontage
        Maximum Area6 sq. ft.
        Maximum Height Above Grade5 ft.
        Minimum Front Property Line Setback5 ft.
        Bonus Sign Area--
        Pylon1
        Number Allowed--1 per 150 ft. of street frontage
        Maximum Area2--32 sq. ft. or 1 sq. ft. of sign area for each 1.5 linear feet of building frontage width,  whichever is greater
        Maximum Height Above Grade--Lesser of the highest point of the building or 25 ft.
        Illumination--Internally lit, Halo lit, or Externally downlit
        Changeable Copy--Not Permitted
        Bonus Sign Area--Yes; See Subsec. 10-1-3.10.E, Sign References and Bonuses

        Table Notes:

        1. 1.
          A joint identification sign is permitted.
        2. 2.
          The maximum total area per sign allowed is 80 square feet per display face and 160 square feet per sign.

        (Ord. 18, Series of 2022; Ord. 20, Series of 2023; Ord. 13, Series of 2025) 

        Effective on: 8/28/2025

        Subsec. 10-3-3.2.A CMU Frontage Types
      10. A.
        Purpose. The purpose for establishing street frontage standards is to ensure that new development or redevelopment occurs within the context of the adjoining properties and surrounding built environment.
      11. B.
        Applicability.
        1. 1.
          Determination. During a pre-application meeting or through staff review, a determination by the Director shall be made as to the required frontage type(s).
        2. 2.
          Criteria. The criteria for use in making a determination of frontage type shall include:
          1. a.
            The context of the proposed development or redevelopment and where such frontage type is deemed applicable;
          2. b.
            The zoning of the subject lot or adjoining lots;
          3. c.
            If frontage is on a commercial corridor, suburban or neighborhood connector, or local street;
          4. d.
            The frontages of developed lots adjoining and on the same side of the street as the subject lot or within 300 feet in either direction of the subject lot along a block front; and
          5. e.
            The established building and parking footprints when the subject lot is developed or proposed for an addition, alteration, or redevelopment.
      12. C.
        Frontage Types and Standards.
        1. 1.
          Build-To Frontage.
          1. a.
            Context. Buildings are set forward on a lot and located a specified distance from the front lot line, as illustrated in Figure 10-3-3.2.A.1, Build-To Frontage.
          2. b.
            Applicability. The Build-To frontage type applies:
            1. 1.
              When at least 60 percent of a block face is established along a build-to line or are generally aligned with one another relative to the street;
            2. 2.
              When buildings within 300' in either direction of the subject lot along a block face are established along a build-to line or are generally aligned with one another relative to the street; or
            3. 3.
              When development is proposed on a lot at an intersection of commercial corridors where buildings, existing or proposed to be constructed, located on any of the adjacent corners are built to the street.
      13. Figure 10-3-3.2.A.1

        Build-To Frontage

        Building Set Forward on a Lot Located a Specific Distance From Street

        Figure 10-3-3.2.A.1

        Build-To Frontage

        Building Set Forward on a Lot Located a Specific Distance From Street

        Figure 10-3-3.2.A.1

        Build-To Frontage

        Building Set Forward on a Lot Located a Specific Distance From Street

        Figure 10-3-3.2.A.1

        Build-To Frontage

        Building Set Forward on a Lot Located a Specific Distance From Street
          1. 2.
            Drive-Through Frontage.
            1. a.
              Context. A drive-through lane as illustrated in Figure 10-3-3.2.A.2, Drive-Through Frontage, may be located on a lot provided compliance with the standards set out in Subsection 10-3-3.2.B, CMU Building and Site Design.
            2. b.
              Applicability. The Drive-Through frontage type applies:
              1. 1.
                Where the use is permitted in Section 10-1-1.3, Land Use Matrix;
              2. 2.
                Where the use is permitted subject to standards as set out in Section 10-1-1.4, Land Use Standards; or
              3. 3.
                Along the interior side or rear elevation of a building.

        Figure 10-3-3.2.A.2

        Drive-Through Frontage

        Drive-Through Located a Specific Distance From Street

        Figure 10-3-3.2.A.2

        Drive-Through Frontage

        Drive-Through Located a Specific Distance From Street

        Figure 10-3-3.2.A.2

        Drive-Through Frontage

        Drive-Through Located a Specific Distance From Street

        Figure 10-3-3.2.A.2

        Drive-Through Frontage

        Drive-Through Located a Specific Distance From Street
          1. 3.
            Green Frontage.
            1. a.
              Context. Buildings are set back from the front lot line and separated from the abutting street right-of-way by a tree-lawn as illustrated in Figure 10-3-3.2.A.3, Green Frontage.
            2. b.
              Applicability. The Green frontage type applies:
              1. 1.
                When development or redevelopment is proposed on lots with frontage on:
                1. i.
                  US 85 / S. Santa Fe Drive;
                2. ii.
                  West Belleview Avenue from South Windemere Street west to the City limits; or
                3. iii.
                  West Mineral Avenue; or
              2. 2.
                When non-residential or mixed-use development is proposed on a lot located across the street from a single-family detached or attached residential use or district.

        Figure 10-3-3.2.A.3

        Green Frontage

        Green Frontage

        Figure 10-3-3.2.A.3

        Green Frontage

        Green Frontage

        Figure 10-3-3.2.A.3

        Green Frontage

        Green Frontage

        Figure 10-3-3.2.A.3

        Green Frontage

        Green Frontage
          1. 4.
            Parking Court Frontage.
            1. a.
              Context. Buildings are set back from the front lot line with the parking located between the building and street as illustrated in Figure 10-3-3.2.A.4, Parking Court Frontage.
            2. b.
              Applicability. The Parking Court frontage type applies when adaptive reuse of existing lots with this frontage type is proposed.

        Figure 10-3-3.2.A.4

        Parking Court Frontage

        Parking Court Frontage

        Figure 10-3-3.2.A.4

        Parking Court Frontage

        Parking Court Frontage

        Figure 10-3-3.2.A.4

        Parking Court Frontage

        Parking Court Frontage

        Figure 10-3-3.2.A.4

        Parking Court Frontage

        Parking Court Frontage
          1. 5.
            Shopfront Frontage.
            1. a.
              Context. Buildings have a narrow front setback from the front lot line with a yard separating the building and abutting street right-of-way as illustrated in 10-3-3.2.A.5, Shopfront Frontage.
            2. b.
              Applicability. The Shopfront frontage type applies:
              1. 1.
                When development is proposed on a lot with frontage on a suburban or neighborhood connector or mixed-use / downtown main street outside of the DMS and DTA districts;
              2. 2.
                When development is proposed on out parcels of a shopping center or multi-tenant development; or
              3. 3.
                When development is proposed on a lot facing a single-family detached or attached residential use or district.

        Figure 10-3-3.2.A.5

        Shopfront Frontage

        Shopfront Frontage

        Figure 10-3-3.2.A.5

        Shopfront Frontage

        Shopfront Frontage

        Figure 10-3-3.2.A.5

        Shopfront Frontage

        Shopfront Frontage

        Figure 10-3-3.2.A.5

        Shopfront Frontage

        Shopfront Frontage
          1. 6.
            Stoop Frontage.
            1. a.
              Context. Buildings have a shallow front yard with individual sidewalks leading from the public sidewalk along the street to the front door and stoop of each unit as illustrated in Figure 10-3-3.2.A.6, Stoop Frontage.
            2. b.
              Applicability. The Stoop frontage type applies:
              1. 1.
                When development is proposed on a lot with frontage on a suburban or neighborhood connector, mixed-use / downtown main street, or mixed-use / downtown connector;
              2. 2.
                When townhouse dwellings are being proposed for development, where permitted;
              3. 3.
                When development is proposed along pedestrian streets within a mixed-use development; or
              4. 4.
                When multi-family, commercial, and mixed-use buildings within a transit shed of a fixed transit stop or station are proposed, where permitted.

        Figure 10-3-3.2.A.6

        Stoop Frontage

        Stoop Frontage

        Figure 10-3-3.2.A.6

        Stoop Frontage

        Stoop Frontage

        Figure 10-3-3.2.A.6

        Stoop Frontage

        Stoop Frontage

        Figure 10-3-3.2.A.6

        Stoop Frontage

        Stoop Frontage
          1. 7.
            Yard Frontage.
            1. a.
              Context. Buildings have a significant setback from the front lot line, as illustrated in Figure 10-3-3.2.A.7, Yard Frontage.
            2. b.
              Applicability. The Yard frontage type applies:
              1. 1.
                Where a business use of a former residential dwelling is proposed; or
              2. 2.
                When dwellings are being proposed in an NC or CM district.

        Figure 10-3-3.2.A.7

        Yard Frontage

        Yard Frontage

        Figure 10-3-3.2.A.7

        Yard Frontage

        Yard Frontage

        Figure 10-3-3.2.A.7

        Yard Frontage

        Yard Frontage

        Figure 10-3-3.2.A.7

        Yard Frontage

        Yard Frontage

        Effective on: 10/28/2021

        Subsec. 10-3-3.2.B CMU Building and Site Design
      14. A.
        Purpose. The purpose of this Section is to establish building and site design standards for development in the NC and CM districts. 
      15. B.
        Applicability. This Section applies to freestanding commercial and mixed-use developments where permitted in Section 10-1-1.3, Land Use Matrix. Where impractical, these provisions may be subject to waiver requests at the sole discretion of the Director or the Director's designee.
      16. C.
        Types of Approval.
        1. 1.
          Site Plan. Development characteristics requiring a Site Plan include:
          1. a.
            The parcel is less than 10 acres in size;
          2. b.
            Construction occurs in a single phase;
          3. c.
            Development includes no more than two buildings; and
          4. d.
            A gross floor area of less than 100,000 square feet.
        2. 2.
          Master Development Plan. Development characteristics requiring a Master Development Plan include:
          1. a.
            A development site of 10 acres in size or more; or
          2. b.
            Construction in two or more phases; or
          3. c.
            Large-scale development with:
            1. 1.
              100,000 square feet of gross floor area or more in a single building, including big-box stores, supermarkets, wholesale stores, and multi-tenant shopping centers; or
            2. 2.
              Two or more separate buildings and a combined square footage of 150,000 square feet or more.
      17. D.
        Mixed-Use Development Layout and Design. Mixed-use development is to be designed to favor the pedestrian more so than the automobile. To create a walkable environment, buildings shall address the street, creating a safe and pleasant streetscape, and be in close proximity to one another. A Master Development Plan for a mixed-use development shall demonstrate adherence to the following design principles:
        1. 1.
          Walkable Layout. Development shall be organized with block lengths that facilitate walkability or include provision for pedestrian accessways that shorten the walking distance between residential, commercial, and public and institutional uses within a mixed-use development.
        2. 2.
          Context-Sensitive Streets. Streets shall be laid out in a hierarchy with a main street and mixed-use and neighborhood connectors that tie into the existing street system to provide for continuity and good access as further defined in the LEDS.
        3. 3.
          Parking. Parking shall be provided on-street to the maximum practicable extent and within parking lots or garages that are placed on the interior of blocks accessed from the side or rear of buildings or alleyways.
        4. 4.
          Connectivity. A pedestrian and bicycle system shall provide connections to peripheral sidewalks and trails and create both on- and off-street linkages tying together residential and non-residential areas, together with civic spaces, schools, transit stops/stations, and parks, in adherence with the Littleton Engineering Design Standards (LEDS).
        5. 5.
          Open Space. Parks and landscape areas shall be located to provide direct connections within and between neighborhoods and areas of employment and commercial services.
        6. 6.
          Resource Integration. Natural resources and environmental features shall be focal points and connected to parking and activity areas by sidewalks, trails, and greenways.
        7. 7.
          Building/Street Relationship. Buildings shall be designed to relate directly to streets and located to create a sense of enclosure and a street environment rich with street-level businesses, amenities, and access to activity areas.
        8. 8.
          Livability. Residential, non-residential, civic, and public transit uses shall related to one another to promote convenience and walkability. Areas designated as residential on a Master Development Plan may include a broad range of residential unit types and related accessory uses. The Master Development Plan may include residential land use sub-areas designating areas of different densities or housing types. Permitted uses are set out in Section 10-1-1.3, Land Use Matrix.
      18. E.
        Design Standards. These site and building design standards apply to all development requiring a Site Plan or Master Development Plan.
        1. 1.
          Unified Design. Commercial centers and their out parcels shall be of a unified design, including use of common design elements, building materials and colors, roof type and material, signage, landscaping and hardscaping, and site access and circulation.
        2. 2.
          Access, Circulation, Parking, and Traffic
          1. a.
            Generally. Vehicular circulation patterns shall be designed to minimize potential conflicts between traffic generated by the site and traffic on adjoining streets, and the number and location of curb cuts shall be as set out in Section 10-1-3.7, Vehicular Mobility.
          2. b.

            Access. Sites shall have frontage on a public or private street classified as a connector or commercial corridor by the Transportation Master Plan. Unless included in the Master Development Plan, vehicle access to local streets in an LLR, MLR, or SLR district shall be prohibited.

          3. c.

            Circulation. The development shall provide for a pedestrian circulation system that provides direct pedestrian and bicycle pathways to surrounding buildings, adjacent parcels, neighborhoods, civic spaces, schools, transit stations/stops, and parks. The plan shall identify the location and width of all sidewalks, crosswalks, mid-block pass-throughs, and connections to adjacent development in adherence with the Littleton Engineering Design Standards (LEDS).

          4. d.

            Parking.

            1. 1.

              Parking shall be designed to:

              1. i.

                Meet the minimum and not exceed the maximum number of parking spaces calculated according to requirements of Subsection 10-1-3.7.A, Parking and Loading; and

              2. ii.

                Comply with the standards for large parking lots set out in Subsection 10-1-3.7.CParking and Loading Design, when a project is considered a large-scale development.

            2. 2.

              Transit-Oriented Development (TOD).

              1. i.
                Parking shall be provided as the cumulative total of each land use or according to the shared parking provisions set out in Subsection 10-1-3.7.AParking and Loading.
              2. ii.
                Within one-quarter mile of a fixed transit station, credit for shared and on-street parking may be granted administratively by the Director.
          5. e.

            Traffic Impact Study (TIS). A traffic impact study may be required by the City Engineer.

        3. 3.
          Site Orientation.
          1. a.

            Street-Facing. Unless otherwise approved by a Site Plan or Master Development Plan, the primary building entrance(s) shall face the street of greater classification type according to the Transportation Master Plan (TMP).

          2. b.

            Parking Setback. All parking and vehicular use areas shall be set back from public rights-of-way and property lines according to the frontage types outlined in Subsection 10-3-3.2.A, CMU Frontage Types. This area shall be credited toward the common open space requirements provided in Section 10-3-2.2CMU Lot and Building Standards, and landscaped according to Section 10-3-4.1CMU Landscaping.

          3. c.

            Street-Facing Side or Rear Elevation. Buildings that share a lot line with a commercial corridor or suburban or neighborhood connector street may be oriented with a side or rear elevation facing the street provided it is constructed with a primary material on 75 percent or more of the building façade or on 50 percent of the building façade together with a Type B bufferyard, as set out in Subsection 10-1-3.6.FBufferyard Requirements.

        4. 4.
          Site Design.
          1. a.
            Landscaping and Bufferyards. Refer to Section 10-3-4.1, CMU Landscaping, and Section 10-3-4.2, CMU Bufferyards.
          2. b.

            Lighting. Lighting shall adhere to the standards in Section 10-1-3.11Outdoor Lighting Standards.

          3. c.

            Signage. Signage shall adhere to the standards out in Section 10-1-3.10Sign Standards, along with those in Article 10-3-5CMU Signs.

          4. d.
            Outparcels. The layout, arrangement, and design of outparcels shall be integrated as part of the overall site, including provisions for joint and cross access, vehicle and pedestrian circulation patterns, and shared parking.
          5. e.
            Service Areas. Loading docks, truck parking, trash collection and compaction, and other functions shall be located in an interior side or rear yard and shall be screened from public view. Such screening shall consist of either an opaque wall that is equal to or greater than the height of the vehicle, equipment, or object to be screened. Alternatively, a fence and a Type B bufferyard, as set out in Subsection 10-1-3.6.FBufferyard Requirements, may be used along all lot lines in public view.
          6. f.
            Civic Spaces
            1. 1.
              ​​​​​Buildings shall be designed to form outdoor spaces such as courtyards, plazas, arcades, terraces, balconies, and decks for residents' and workers' use and interaction, and to integrate the development with the adjacent physical context.
            2. 2.

              At least two of the following improvements shall be incorporated into the design of a project warranting a Master Development Plan:

              1. i.
              2. ii.

                Patios with seating areas;

              3. iii.

                Pedestrian plaza with fixed seating and a design feature as a focal point;

              4. iv.

                Water feature(s);

              5. v.
                Picnic pavilion;
              6. vi.
                Public art installation;
              7. vii.
                Performance stage
              8. viii.

                Clock tower; or

              9. ix.

                Other amenities approved by the Director.

        5. 5.
          Buildings. New development and redevelopment shall meet these building design standards. Substantial improvement of existing buildings shall meet these standards to the extent practicable.
          1. a.
            Bulk and Scale. Front and corner street building elevations shall be partitioned into a series of smaller wall segments and planes that correspond to, or give the appearance of, individual tenant spaces. The partitioned wall segments shall vary in width and height, with the narrowest being 25 feet and the widest being no greater than 40 percent of the largest tenant space. Such wall segments shall relate to the required articulation. In the instance of an anchor building, walls shall be modulated to reduce the mass of the building, add visual interest, and contribute to the pedestrian environment. 
          2. b.

            Articulation. Where practicable, street-facing elevations shall not exceed 65 horizontal feet without including at least three of the following elements:

            1. 1.
              Decorative ornamentation such as corbels, medallions (non‐signage), niches, wrought iron, balconettes, horizontal and rhythm patterned brickwork, or other features approved through the Site Plan or Master Development Plan process;
            2. 2.

              Complementary changes in materials or texture;

            3. 3.

              An offset, column, reveal, void, projecting rib, band, cornice, or similar element with a minimum depth of six inches;

            4. 4.

              Vertical elements such as tower, cupola, turret, arches, etc.;

            5. 5.

              Raised pilaster cornices (end columns at corner) or quoined corners; or

            6. 6.

              Canopies, awnings, porticos with colonnade, or arcades.

          3. c.
            EntrywaysFacades with public entrances shall be clearly defined and include at least four of the following architectural components:
            1. 1.
              Canopies, porticos, or overhangs;
            2. 2.
              Recesses and projections;
            3. 3.
              Arcades;
            4. 4.
              Raised parapets with cornices;
            5. 5.
              Peaked-roof forms;
            6. 6.
              Arches;
            7. 7.
              Display windows; and
            8. 8.
              Integrated architectural detailing such as tile work, moldings, and wing walls.
          4. d.
            Street Walls. The first floor of all commercial uses shall be designed to encourage pedestrian interest and activity by incorporating:
            1. 1.
              Transparent windows and doors arranged so that the uses inside are visible from and/or accessible to the street on at least 25 percent of the length of the first floor building elevation; and
            2. 2.
              Expanses of blank walls shall comply with the standards set out in Subsection 10-1-3.1.C, Blank Walls.
          5. e.
            Building Wall and Roofline Offsets. Building wall offsets, including projections, recesses, and changes in floor level shall be used to add architectural interest and variety, relieve the visual effect of a single, long wall, and subdivide the wall into human-scale proportions.
          6. f.
            Elevations.
            1. 1.
              Building entrances shall be clearly distinguishable through their architectural design and treatment.
            2. 2.
              Buildings shall provide detailed design by using no less than two of the following or other proposed architectural features for the proposed building type and style:
              1. i.

                Window hoods or canopies;

              2. ii.

                Storefront (mid-wall) cornice;

              3. iii.

                Transom windows;

              4. iv.

                Masonry piers (rhythmically-spaced);

              5. v.

                Ground-level bulkhead;

              6. vi.

                Recessed entries; and 

              7. vii.

                Bay window or balcony.

          7. g.
            Materials. B​​​​​uilding walls shall utilize building materials set out in Section 10-3-3.1, CMU Building Materials.
            1. 1.
              Street-Facing Elevations. Buildings shall be designed to include primary building materials on 60 percent of the front and corner street building elevations.
            2. 2.
              Side and Rear Elevations. Buildings on an out parcel, within a mixed-use development, or adjoining another use or parking lot shall be designed to include primary building materials on 60 percent of the side and rear elevations.
            3. 3.
              Accessory Buildings. Accessory buildings, such as parking garages, porte-cocheres, storage facilities, car washes, and other similar buildings must be designed as integral to the overall site development and architecture. Building materials, colors, and roof types shall be consistent with or compatible with the principal building(s).
          8. h.
            Roofs. Roof forms and rooflines shall be broken into a series of smaller building components when viewed from the street.
            1. 1.

              For flat roofs in the Corridor Mixed (CM) district or facades with a horizontal eave, fascia, or parapet, the minimum vertical dimension of roofline modulation is the greater of two feet or 10 percent of the wall height (finish grade to top of wall).

            2. 2.

              For other roof forms, individual segments of the roof with no change in slope or discontinuity may not exceed 40 percent (measured horizontally) of the roof length.

            3. 3.

              Roofs shall be clad in standing seam metal, corrugated metal, slate, asphalt shingles, or synthetic materials similar and/or superior in appearance and durability.

          9. i.
            Building Canopy. A building canopy, awning, or similar weather protection may be provided. Where provided, the canopy should project a minimum of eight feet from the facade when used above a primary building entrance.
        6. 6.
          Drive-Through Aisles.
          1. a.

            Surface. The surface of drive-through aisles and bypass lanes shall be paved with asphalt, concrete, or impervious paving meeting load standards as determined by the City Engineer.

          2. b.

            WidthDrive-through aisles and bypass lanes shall be a minimum width of 10 feet.

          3. c.

            Stacking. Drive-up windows shall provide stacking space that complies with the standards set out in Subsection 10-1-3.7.C, Parking and Loading Design.

          4. d.

            Bypass Lane. The order lane shall either include a parallel bypass lane or a means of vehicle exit before reaching the order station.

          5. e.

            Intersection. Each drive-through entrance and exit, when accessing a public right-of-way or private street, shall be subject to the driveway spacing standards in Subsection 10-1-3.9.B, Vehicular Access and Circulation. An exception may be granted if meeting the spacing standards is impossible and the drive-through aisle is located where it is most nearly consistent with the spacing requirements.

          6. f.

            Traffic Conflict. The facilities and queuing lanes shall be located and designed to minimize turning movements in relation to driveway access to streets and intersections.

          7. g.

            Lane Markings. Each entrance to an aisle and the direction of traffic flow shall be clearly designated by signs and pavement markings. Pedestrian walkways that intersect the drive-through aisles shall be clearly visible and delineated by textured and/or painted paving.

          8. h.

            LandscapingDrive-through aisles shall include shrubs measuring to a minimum height of three feet, planted at a rate of one shrub for every five linear feet abutting street rights-of way.

          9. i.

            Parking. The provision of drive-through service facilities shall not justify a reduction in the number of required off-street parking spaces for the accompanying use.

          10. j.

            Order and Pick-Up Windows. Where drive-through order or pick-up windows are located on a  building elevation facing, or approximately facing, a street or development entrance, the length of the lane that is parallel to the street or entrance shall be screened by a berm, wall, continuous row of shrubs, or a difference in ground elevation of no less than 30 inches.

          11. k.

            ScreeningDrive-through uses shall construct a six-foot tall opaque wall or fence along adjoining property that shares a common property line with an LLR, MLR or SLR district.

        7. 7.
          Structured Parking.
          1. a.
            Access. Structured parking shall be located to the interior side or rear of the principal building and shall be accessed from an alley or a connector street. Curb cuts shall be placed where they are least likely to impede pedestrian circulation.
          2. b.
            Wrapping. Where a parking structure fronts on a commercial corridor or connector street as defined in the Transportation Master Plan, non-residential uses shall be required along no less than 50 percent of the ground-level frontage. 
          3. c.

            Screening. All open portions of any street-facing elevation shall include a screen device with no less than 50 percent opacity for the areas between parking decks and on the roof of the structure.

          4. d.

            Landscaping. A Type A bufferyard shall be planted along all street-facing elevations to screen the view of parked vehicles.

          5. e.
            Lighting. Structures shall be well-illuminated to provide security. The lighting shall be a minimum uniformly distributed 40 footcandles so dark areas are not created. Low-energy, high-efficiency (fluorescent, LED, etc.) lighting shall be used whenever feasible. All stairways and elevator lobbies shall be well-illuminated and, if possible, visible to the outside.
          6. f.
            Security. Security measures shall be incorporated into the design of all parking structures, reviewed for consistency with Section 10-1-3.2-2, CPTED (Crime Prevention Through Environmental Design), and reflected on the Site Plan, Master Development Plan, or building plans.
          7. g.

            Design.

            1. 1.

              The exterior elevations of a parking structure with frontage on a street or common open space shall be designed to match or complement the materials and colors of the principal building.

            2. 2.

              In considering an application for development approval, the Director will evaluate the proposed structured parking facility based on these criteria:

              1. i.

                Architectural treatments designed to minimize visual impacts, including, but not limited to, false façades, buildings wrapping the ground floor, or substantially opaque screening as specified above;

              2. ii.

                Effectiveness of the landscape to reduce the perception of bulk, enhancing the façade, screening side and rear elevations, and integrating the landscaping with the overall site and landscape design;

              3. iii.

                Effectiveness of buffering to screen or block views of the parking structure from adjacent residential uses and districts;

              4. iv.

                Lighting design to control light trespass and spillover onto public rights-of-way and adjoining or adjacent uses;

              5. v.

                Provision of vehicular and pedestrian access and circulation; and

              6. vi.

                Safety and convenience of ingress and egress.

      19. (Ord. 18, Series of 2022; Ord. 20, Series of 2023) 

        Effective on: 10/13/2023