Zoneomics Logo
search icon

Wildwood City Zoning Code

SECTION 415

360 Minimum Loading Requirements.

[R.O. 1997 § 415.360; Ord. No. 1324 App. A § 1003.165H, 8-14-2006]
When required in conjunction with uses specified elsewhere in this Chapter, loading spaces shall be provided in accordance with the following tables:
TABLE A
Gross Floor Area (Square Feet)
Number Of Minimum 10 Foot By 40 Foot Loading Spaces*
5,000 — 24,000
1
24,000 — 60,000
2
60,000 — 96,000
3
96,000 — 144,000
4
144,000 — 192,000
5
192,000 — 240,000
6
240,000 — 294,000
7
294,000 — 348,000
8
For each additional 54,000
1 additional loading space
* Each 10 feet by 40 feet loading space shall have a height clear of obstruction of not less than 14 feet.
TABLE B
Gross Floor Area (Square Feet)
Number Of Loading Spaces
10 Feet By 25 Feet Minimum
Number Of Loading Spaces
10 Feet By 40 Feet Minimum*
2,000 — 10,000
1
0
10,000 — 25,000
2
0
25,000 — 100,000
2
1
For each additional 100,000
1 additional
1 additional