Zoneomics Logo
search icon

Montgomery Town City Zoning Code

§ 235-13.1

Schedule of permitted and special permitted signs.

[Amended 10-6-2022 by L.L. No. 10-2022]
A. 
The following schedule of permitted signs shall apply to each premises according to the district in which it is located on the Zoning Map, whether it be used for a permitted use or for a special permit use:
Permitted Signs - Residential and Agriculture Districts
Type of Sign
Number of Signs Permitted
Professional or announcement sign
Pursuant to § 235-13.2
Personal identification sign having an area not greater than 2 square feet
Permitted
Real estate "for sale" or "for rent" sign or construction sign
1 on each public street frontage for single lots or buildings; 2 subdivision signs on each public street frontage for each approved subdivision, pursuant to § 235-13.5A
Temporary sign
Pursuant to § 235-13.6B
Permitted Signs - Business Districts (B-1, B-2, B-3 and Crossroads Commercial Overlay District)
Type of Sign
Number of Signs Permitted
Professional or announcement sign
Pursuant to § 235-13.2
Business identification signs
Pursuant to § 235-13.3
Real estate "for sale" or "for rent" sign or construction sign
1 on each public street or frontage for single lots or building; 2 subdivision signs on each public street frontage for each approved subdivision, pursuant to § 235-13.6
Temporary sign
Pursuant to § 235-13.6B
Permitted Signs - I-1, I-2, and I-3 Districts
Type of Sign
Number of Signs Permitted
Professional or announcement sign
Pursuant to § 235-13.2
Business identification signs
Pursuant to § 235-13.4 (I-2, I-3) or § 235-13.5 (I-1)
Real estate "for sale" or "for rent" sign or construction sign
1 on each public street or frontage for single lots or buildings; 2 subdivision signs on each public street frontage for each approved subdivision, pursuant to § 235-13.6
Temporary sign
Pursuant to § 235-13.6B
B. 
Special regulations for all permitted business and industrial business identification signs.
(1) 
Sign construction specifications. All signs which exceed 15 feet in height shall require plans approved by a licensed professional engineer or architect and:
(a) 
Supports on lighted signs shall be steel pipe, tubing or I-beams;
(b) 
Metal facings shall not be less than 24 gauge;
(c) 
Plastic facings shall not be less than 1/8 inch thick up to 32 square feet, 3/16 inch up to 250 square feet, and 1/4 inch over 250 square feet, provided bumpers are spaced 48 inches on center within the interior of the sign cabinet; and
(d) 
Electrical wiring shall be in accordance with Underwriter Laboratories specifications and signs shall bear the Underwriter Laboratories label.
(2) 
One identification-directional sign with an area of not more than eight square feet per side shall be permitted at each point of access to a lot, set back at least five feet from the property line, which shall not obstruct the view of exiting motorists and shall not exceed 10 feet in height.
(3) 
On-site directional signs shall not exceed 10 feet in height unless mounted on a building or structure other than a sign structure. Such signs shall not exceed eight square feet in area.
(4) 
More than one wall sign may be permitted per wall surface, provided the total sign area of all signs on the wall does not exceed the total sign area permitted in §§ 235-13.3 through 235-13.5.
(5) 
Signs may be interior-lighted with nonglaring lights or may be illuminated by shielded floodlights; provided, however, that red and green lights shall be set back at least 75 feet from the point of intersection of the street lines at a street corner; and further provided that intermittent or flashing lights shall not be used on or in any sign or in conjunction with any sign. Moving or animated signs shall be prohibited.
C. 
Regulations for special permitted business and industrial business identification signs.
(1) 
The Planning Board may issue a special permit for business or industrial ground-mounted signs which do not comply with these regulations only when such sign, if it were to comply, could not be seen by a motorist for the time required as shown on Column Two of the table below for the type of road indicated on Column One due only to terrain conditions:
Road Type
Reaction Time
(seconds)
Speed
(mph)
Sight Distance
(feet)
Minimum Letter Height
(inches)
Expressway
15
55
1,200
21
4 lanes
10
55
810
17
4 lanes
10
50
730
15
4 lanes
10
45
660
13
4 lanes
10
40
590
11
2 lanes
8
55
645
14
2 lanes
8
50
590
12
2 lanes
8
45
530
10
2 lanes
8
40
470
9
2 lanes
8
35
410
8
2 lanes
8
30
350
7
2 lanes
8
25
290
5
(2) 
The applicant shall agree to make the letters no smaller than the minimum size shown in the table above and no larger than four feet in height, and limit the message to no more than 16 message units in four lines of words, with no more than 26 letters per line. For the purpose of this subsection, a message unit is a symbol or a syllable.
(3) 
Any sign permitted by the Planning Board shall be the minimum size necessary for the purposes stated by the applicant, in the opinion of the Planning Board.