search icon

Enoch City Zoning Code

12.2700 CIVIL

PLANS AND PROFILE DRAWINGS

12.2700.2701 CIVIL PLANS AND PROFILE DRAWINGS

Civil plans and profile drawings shall be delivered by one of the following: CD, USB flash drive, or e-mailed zip file (not to exceed 20 MB). The must be in .pdf format and either AutoCAD format (DWG or DXF), Geodatabase format (GDB), or Shapefile format (SHP) and must have a projection assigned to the file(s). Submitted final plats must also include the proper metadata that describes what coordinate system/projection the data being delivered is assigned to. With 3 hard copies on 24"x 36" (trim line). Drawings submitted for approval shall include:

  1. Title Block with:
  2. Name of subdivision and date.
  3. Name of City.
  4. Type of work.
  5. Name of Engineer preparing drawings.
  6. Space for approval of the City Engineer.
  7. North Arrow and Scales. Horizontal scale preferred is 1-inch equals 50 feet; Minimum scale is 1-inch equals 10 feet. Vertical scale preferred is 1-inch equals 50 feet; minimum scale is 1-inch equals 10 feet.
  8. Location of permanent benchmarks and their true elevations according to United States Geological Service Datum. All profiles shall conform to the standards of the profession.
  9. Profiles shall indicate finished and existing grades for each side of the street and shall extend a minimum of two hundred (200) feet beyond the limits of the proposed project.
  10. Plans and Profiles shall also include details of:
  11. Curb and gutter (if any);
  12. Sidewalks (if any);
  13. Street cross-sections;
  14. Location and elevations of manholes, catch basins, storm sewers and their appurtenant works;
  15. Elevations and location of fire hydrants, water mains, type of pipe, valves and their appurtenant works;
  16. Location, size, and elevations of sewer mains with their grades and type of pipe (rubber gasket mandatory);
  17. Manholes;
  18. Clean outs;
  19. Other appurtenant works; and
  20. A non-culinary (irrigation) water system, if any, indicating size, location, and kind of pipe, valves and turnouts.
  21. On curb returns, at least one additional control point for elevation besides those at the P.C and P.T. shall be indicated on the plans and staked in the field to insure drainage at the intersections. Complete curve data must be shown for all horizontal and vertical curves. Minimum length of vertical curve is two hundred (200) feet, unless otherwise approved.
  22. Elevations for the top of curbs and road center lines shall be shown on the plans for all 50-foot stations, all BVC’s and EVC’s. Street monuments shall be installed by the subdivider/developer’s engineer or land surveyor at points designated on the final map. They must be placed prior to release of the completion assurance.
  23. After City approval, one set of drawings shall be returned to the subdivider/developer and shall be available at the work site.
  24. As Built Drawings. Upon completion of each improvement a reproducible copy and two (2) prints of “As Built Drawings” shall be prepared and submitted by the subdivider/developer’s engineer, to accurately define for permanent record the improvements and underground utilities as they were actually constructed.