111 TRANSIT ORIENTED DEVELOPMENT PACKING HOUSE DISTRICT DEVELOPMENT STANDARDS
Table 1. Allowed Land Uses and Permit Requirements |
|---|
P – permitted |
UP – use permit |
NP – not permitted |
Land Use Type | Permit Requirement | Specific Use Regulations |
|---|---|---|
Recreation, Education, Public Assembly Uses | ||
1. Commercial recreation facility – indoor | NP | |
2. Conference/Convention Facility | NP | |
3. Health/Fitness Facility, including stand alone or roving fitness classes | NP | |
4. Library, Museum | P | Permitted only in the historic Packing House building.1 |
5. Park, Playground | P | Only permitted when integrated into the overall development of a site. |
6. School – specialized education, training | NP | |
7. Studio – art, dance, martial arts, music, cooking, fitness (such as yoga, Pilates, spin, etc.) | P | Permitted only above the ground floor within a mixed use development or above the ground floor of the Packing House building. Only one studio per development. |
8. Theatre (live performing arts) | P | Movie cinemas not permitted. |
Residential Uses | ||
9. Emergency Shelter | NP | |
10. Home Occupation | P | PMC Section 23.81.020. No additional parking shall be permitted for those units with home occupation. |
11. Live Work, in Packing House Building | P | |
12. Live Work | UP | |
13. Mixed Use Project with Residential | P | Maximum of 3 bedrooms per unit; 15% of all units may be up to 3 bedrooms. The design and construction of multifamily residential developments as courtyard housing projects is encouraged. Ground floors in mixed use projects must be plumbed/planned restaurant infrastructure including exhaust and grease control device. |
14. Multifamily Residential, Catalyst Site | UP | Maximum of 3 bedrooms per unit; 15% of all units may be up to 3 bedrooms. Project with only multifamily residential are permitted only on the “catalyst site.” See definition of “catalyst site.” |
15. Non Mixed Use Project with a parcel size under 20,000 square feet | UP | Must be commercial on ground floor. May also include commercial, residential or office above ground floor. Must meet all other development standards. Must meet the intent and purpose of this chapter. |
16. Residential Only | NP, except as permitted as a catalyst site as described in definitions. | |
Retail/Commercial Uses | ||
17. Accessory Retail or Services | P | Only permitted when primary commercial use is established. Must be incorporated into mixed-use or within Packing House; cannot stand alone. |
18. Adult Entertainment Facility or Business | NP Pursuant to PMC Ch. 23.89 | |
19. Alcoholic Beverage Sales (not associated with bar, brewery, distillery, restaurant, or neighborhood market or grocery) | NP | |
20. Antique or Collectible Store | P | Must be incorporated into mixed-use or within Packing House; cannot stand alone. |
21. Artisan Shop | P | Must be incorporated into mixed-use or within Packing House; cannot stand alone. |
22. Auto Repair or Auto Parts Sales | NP | |
23. Bar, Tavern, Brewery, Distillery, Tasting Rooms, Wine Cellar | UP | Must be incorporated into mixed-use or within Packing House; cannot stand alone. |
24. Neighborhood Market (without alcohol beverage sales) | P | With alcohol sales, a use permit is required. |
25. Drive-Through (any uses) | NP | |
26. Furniture, Furnishings and Appliance Store | NP | |
27. General Retail – less than 5,000 sf | P | Must be incorporated into mixed-use or within Packing House; cannot stand alone. |
28. General Retail –5,000 sf to 20,000 sf | UP | Must be incorporated into mixed-use or within Packing House; cannot stand alone. |
29. General Retail – more than 20,000 sf (max 60,000 sf) | NP | |
30. Groceries, Specialty Foods – 10,000 sf or less | P | With alcohol sales, a use permit is required. |
31. Groceries, Specialty Foods – more than 10,000 sf | UP | |
32. Medical Marijuana Facilities | NP Pursuant to PMC Ch. 23.46 | |
33. Nightclub (including comedy clubs) | UP | Must be incorporated into mixed-use or within Packing House; cannot stand alone. “Hostess” clubs are not permitted. |
34. Outdoor Dining | P | Permitted in public right-of-way with an encroachment permit. Pursuant to ABC requirements as well as the outdoor dining permit and guidelines. |
35. Outdoor Display and Sales | NP | May be permitted with a special event permit as part of a coordinated event, pursuant to PMC Section 23.81.015. No more than 4 a year. |
37. Restaurant with Alcohol Sales | UP | Must be incorporated into mixed-use or within Packing House; cannot stand alone. |
38. Restaurant | P | Must be incorporated into mixed-use or within Packing House; cannot stand alone. |
39. Secondhand/Thrift/Pawnshop/Charity Store | NP | |
40. Service Station | NP | |
41. Tobacco Sales, including electronic smoking devices | UP | |
Services – Business, Financial, Professional | ||
42. ATM | P | Must be integrated into building façade. Stand alone kiosks not permitted. |
43. Bank, over 2,000 sf | NP | Small banks of 2,000 sf or less are permitted. |
44. Medical Services | UP | See definition. May only be permitted on 2nd story of mixed-use development. |
45. Office | P | Upper floors; or in conjunction with live/work. Must be incorporated into mixed-use or within Packing House; cannot stand alone. May only be permitted on 2nd story of mixed-use development. |
Services – General | ||
46. Adult Daycare | NP | |
47. Commercial Daycare Center | NP | Large family daycare facilities not permitted. All child care facilities shall be integrated into the over development. |
48. Lodging – Bed and Breakfast | UP | Maximum of 10 beds allowed. Are not required to contain residential units or uses. |
49. Lodging – Hotel | UP | Are not required to contain residential units or uses. Permitted within 250 feet (verify) of freeway right-of-way. 1st floor must include 25—50% of floor area as retail or restaurant or conference area. Retail/restaurant uses must be consistent with mixed use standards. Must include conference center. |
50. Massage Establishments | UP Pursuant to PMC § 23.30.030 | |
51. Personal Services | P | Must be incorporated into mixed-use or within Packing House; cannot consist of a stand-alone use or building. May only be permitted on 2nd story of mixed-use development or Packing House. |
52. Public Safety Facility | NP | Except that city police department satellite stations are permitted. Satellite stations may not be stand alone facilities. |
53. Spa Services | UP | Must be incorporated into mixed-use or within Packing House; cannot stand alone. May only be permitted on 2nd story of mixed-use development. Must include a full suite of services. |
54. Spa Services with Alcohol | UP | Must be incorporated into mixed-use or within Packing House; cannot stand alone. May only be permitted on 2nd story of mixed-use development. Must include a full suite of services. |
55. Cigar or Hookah Lounge | UP | |
56. Meeting Halls, Banquet Centers (stand alone) | NP | |
57. Tattoo Parlors/Body Modification | UP | |
58. Hostess Bars | NP | |
Transportation, Communications & Infrastructure | ||
59. Broadcasting or Recording Studio | UP | Must be incorporated into mixed-use or within Packing House; cannot stand alone. May only be permitted on 2nd story of mixed-use development. |
60. Public Parking Structure | P | |
61. Transit Station or Terminal | P | |
62. Telecommunication Cell Tower | Pursuant to PMC Ch. 23.82 | |
Historic Packing House Building | ||
63. Adaptive Re-Use of Packing House Building. The building and property located at 341 S. Melrose Street is a local historic building and is listed on the California Register. As an historic building, it is eligible for adaptive re-use in order to preserve the historic elements and quality of the building and property. | UP, subject to an adaptive re-use plan prepared by a qualified preservation expert as deemed appropriate by the city. | Adaptive re-use plan may be reviewed for comment by the city of Placentia historical committee. The adaptive re-use of this building is not subject to any development standards contained in this chapter, however a finding must be made that the reuse plan meets and is consistent with the intent and purpose of this chapter. |
Notes: | |
|---|---|
1 | The Packing House Building is located at 341 S. Melrose Street. |
Table 2. Development Standards | ||
|---|---|---|
Standard | Notes | |
Architectural Review | ||
High quality, 360 degree, architectural and urban design is required. All new projects will require architectural review by a third party architectural expert, selected by the city. | Third party review costs are the responsibility of the applicant. | |
Building Placement Regulations | ||
1. Density | 65 dwelling unit/acre minimum and 95 dwelling units/acre maximum | Density shall be calculated using gross lot size, prior to any required right-of-way dedications. Dedications shall be required along Crowther Avenue. |
2. Block Length and Lot Size Requirements. Each project along Crowther Avenue shall create an active and inviting environment for pedestrians. | ||
a. Maximum Building Length without Breaks in Building Massing | 350 ft. | Breaks in building massing mean courtyards, plazas, outdoor dining, etc. These should be open from ground to sky and constitute a true break in the building massing. |
b. Lot Depth | No minimum lot depth | Integrated developments and lot consolidations are encouraged with lot orientation fronting on Crowther Avenue, and where possible, with parcels extending from Crowther to the railroad right-of-way. |
c. Minimum Lot Size | 20,000 square feet | |
3. Setbacks. Minimum setbacks required and, where noted, maximum setbacks established, except where a frontage type standard allows exceptions or establishes different requirements. Setbacks are measured from property line after any required dedications. Fire department requirements supersede any setback listed below. | ||
a. Setback From Railroad Track | 0 feet | 10 ft. from rear ROW preferred by BNSF for above ground structures. Applicants should consider access to rear portion of new development. |
b. Front Yard Setback | 3 ft. min./15 ft. max. | |
c. Side Yard Setback | 0 feet, or 10 ft. when adjacent to a property containing residential uses. | |
d. Rear Yard Setback | 10 ft. | |
e. Street Side Yard Setback | 5 ft. min./15 ft. max. | |
4. Projections | ||
a. Allowable Setback Projections. | ||
i. Ground Floor: | ||
• Awnings and canopies over windows: 60 inches; | ||
• Sun shade structures: 15 feet; | ||
• Bay windows: 60 inches (not wider than 10 feet); | ||
• Cornices, belt courses, and similar architectural features: 12 inches; | ||
• Eaves, roof overhangs: 30 inches; and | ||
• Uncovered porches, decks and landings (may be covered by arbors or trellises): 10 feet. | ||
ii. Above Ground Floor. Awnings, galleries, balconies, bay windows: 48 inches. | ||
iii. Art, as determined by the approval of the public art component of the project. | ||
iv. For signs, see Sign Regulations, § 23.110.050. | ||
v. All projections must maintain a minimum of 8 feet vertical height from ground. | ||
b. Public right-of-way encroachments require approval of an encroachment permit. | ||
5. Building Height, Rooftop Amenities, Frontages, and Ground Floor | ||
a. Building Height | 3 stories minimum, 35 ft. minimum, 5 stories maximum, not to exceed 68 ft. | |
b. Frontage Requirements. In order to support the pedestrian environment, building frontages onto streets and open spaces shall be maximized. No visible parking is permitted along frontages. A minimum of 75% of the site frontage shall be occupied as building frontage. A section of blank wall shall not exceed 20 linear feet without being interrupted by a window or entry or other façade treatment. | ||
c. Where commercial uses are required on ground floors, those commercial uses shall have a minimum 15 ft. floor to ceiling height. | ||
6. Provision of Common Open Space (Residential Portion Only) | ||
a. Amount per residential use | 50 sf/unit for residential units; 50 sf/unit for 5 or more live work units. | Up to 75% of this requirement can be fulfilled by providing a public plaza in lieu of private common open space. |
b. Types of Common Open Space Permitted | • Common open space can be active or passive but must be accessible to all non-residential tenants (i.e., employees and employers) and residential residents. | |
• Required setbacks may not be counted as common open space, except that rear yards counted as meeting the requirement for live/work units. | ||
• Common open space shall be fully landscaped and requires an approved landscape plan. | ||
• Examples may include: courtyards, clubhouses with accompanying landscaped areas, swimming pools, plazas, greens, parks, playgrounds, picnic areas, outdoor seating. | ||
c. Rooftop Amenities | Rooftop amenities are permitted if they provide additional recreational or common open space activities for the residents of the building. | |
• 50% of the rooftop amenities (structures and active recreation amenities) may count towards the square footage requirement for either private or common open space. | ||
• Rooftop amenities, such as and not limited to, clubhouses, swimming pools, tennis courts, open space areas, fitness centers, are permitted to project 16 ft. above the maximum height limit if integrated into the overall design of the project and the maximum rooftop building coverage is limited to 30% of the rooftop floor area. | ||
• Roof top amenities shall be set back from the building edge such that no more than 20% of the rooftop structure can be visible from the primary public right-of-way at centerline of the street. | ||
• Rooftop amenities are intended for the use of building residents. | ||
d. Courtyard Common Open Space Requirements | Courtyards shall be designed as a central courtyard or as partial, multiple, separated or interconnected courtyards. | |
• Minimum courtyard dimension shall be 40 ft. when the long axis of the courtyard is oriented EW and 30 ft. for a NS orientation. The courtyard proportion is 1:1 between its width and height for at least 2/3 of the court’s perimeter. As long as total open space requirement is met, this ratio could be modified by up to 10%. | ||
• When there are 2 or more courtyards, they shall be connected to each other. | ||
• The area required for first level patios shall not be deducted from the overall courtyard area. | ||
7. Provision of Private Open Space (Residential Portion Only) | ||
a. Live Work | 64 sf/unit | 6 ft. min. in any direction; the total of 64 sf must be provided as 1 private open space area, not broken up into smaller sizes. |
b. Residential-Attached & Multifamily | 64 sf/unit | 6 ft. min. in any direction; the total of 64 sf must be provided as 1 private open space area, not broken up into smaller sizes. |
8. Parking | Standards | Applicable Land Uses |
a. Retail – spaces per 1,000 sf | 2 min./4 max. | Accessory retail, antique, artisan, general retail, grocery, retail complex, personal services |
b. Eating and Drinking Establishments – spaces per 1,000 sf | 5 min./10 max. | Bar/tavern, restaurant, brewery, etc. |
c. Outdoor Dining on Private Property | 0 | • Outdoor dining is encouraged and shall be incorporated as part of the overall design of the building or project. • Outdoor dining may project into required setbacks. |
• No parking is required for outdoor dining unless the total outdoor dining square footage is greater than the total interior dining area. In this circumstance, project must provide parking for the amount over the interior square footage. • Acceptable barriers for defining outdoor dining areas shall include fences, railings, and planter boxes. | ||
d. Specialty Goods & Foods– spaces per 1,000 sf | 2 min./4 max. | |
e. Entertainment & Recreation – spaces per 1,000 sf | 6 min./10 max. | Health/fitness, playgrounds, studios, theatres cannot be stand alone. |
f. Commercial Goods – spaces per 1,000 sf | 2 min./4 max. | |
g. Civic & Cultural, including Libraries and Museums – spaces per 1,000 sf | 3 min./no max. | |
h. Office Professional – spaces per 1,000 sf | 2 min./4 max. | |
i. Personal Services | 3 min./no max. | |
j. Live Work | 1 min./1.5 max. | |
k. ATM | 0 | |
l. Lodging – B&B | 1 per sleeping room. | No assembly space permitted. |
m. Lodging – Hotel | 1 per sleeping room, plus 1 space for every 75 sf of assembly area. | |
Residential | ||
n. Spaces per studio unit | 1 min./1 max. | |
o. Spaces per 1 bed unit | 1 min./1.5 max. | |
p. Spaces per 2 bed unit | 1.5 min./2 max. | |
q. Spaces per 3 bed unit | 2 min./2.5 max. | |
r. Guest spaces per 10 units | 2 min./3 max. | |
s. Mixed Use | Parking shall meet the requirements for individual land uses. Residential parking shall be separated from non-residential parking and easily accessible through a controlled mechanism. | Reduced parking may be permitted through a parking study. |
Other | ||
t. Bike Parking – Short-Term | Residential: 1 resident bicycle parking space for every 5 residential units, or portion thereof; Nonresidential: 1 bicycle parking space for every 5,000 sf, or portion thereof, of nonresidential floor area. | |
u. Bike Parking – Long-Term | Residential: 2 bicycle storage units for every 5 dwelling units for the first 20, and 1 for every 5 additional units, or portion thereof; Nonresidential: Any establishment with a parking structure and a minimum of 10,000 sf of nonresidential space shall provide long-term bicycle parking at a minimum ratio of 1 space per 20 vehicle spaces. | |
v. Electric Vehicle Charging Stations. | Minimum 10% of project’s parking spaces must provide EV Level 2 charging stations. Alternatively, 5% of total spaces if installing DC fast charging stations. | |
w. Transit Station or Terminal. | As per director of development services in coordination with transportation authority. | |
x. Telecommunication Facility | 1 space to service facility. | |
y. Surface Parking. | Surface parking is permitted as long as not visible from public street and is fully landscaped and screened from public view. | |
z. Parking Structure. | Structure parking permitted only if integrated into overall design of building and “wrapped” with the building, such that the parking area is not visible from any portion of the front, sides, rear or interior courtyards of the project. | |
aa. Podium Parking. | Permitted if fully integrated into a development with a “wrapped” parking structure. | |
bb. Underground Parking. | Permitted if fully integrated into the design of the development. | |
cc. Parking Reduction. | Applicants may apply for parking reduction before the planning commission for residential and mixed use projects up to a maximum reduction of 25% through a parking demand study or shared parking analysis. One such incentive could include a Zip car or shared car plan. | |
Table 3. Sign Standards by Use | |||
|---|---|---|---|
Multi-Family Residential Use | |||
Allowed Sign | Maximum Sign Height | Maximum No. of Signs Allowed per Parcel | Maximum Sign Area Allowed per Parcel |
i. Wall or Freestanding | Wall signs: below edge of roof. Freestanding: 48″ | 1 wall sign or freestanding sign per entrance or street frontage. | 12 sf each per face area; 24 sf maximum total sf for all signs. |
Nonresidential Use/Mixed Use | ||
|---|---|---|
Allowed Sign | Placement Standards | Maximum Number and Sign Area |
i. Awning | Shall be entirely on awning valence; lettering max 66% of valence height; valence height max: 18″. | 50% of the area of the valence front. 1 sign max per each separate awning valence. |
ii. Marquee | To be established during project review. Allowed only for the entrance of a theatre or playhouse. | To be established during project review. 1 sign max. |
iii. Monument | 5 ft. including base structure. Allowed only on a site with more than 100 ft. of continuous street frontage. | 36 sf |
iv. Projecting or Suspended | 16″ from face of building and bottom of sign shall be no closer than 8 ft. above sidewalk surface below. | 6 sf. No dimension greater than 3 ft. Sign shall be redwood sandblasted, hand carved or architecturally designed. |
v. Wall | 2 ft. below parapet or eave. Individual letters 18″. Mounting 1-story: above 1st floor windows. Mounting multi-story: between windows. | 1 sf per linear foot primary business. 1 sign allowed per business frontage with pedestrian entrance. Side street or rear entrance wall sign max 50% of the primary sign area. |
vi. Window Permanent | Within window area. | 15% of total window area max. |
vii. Window Temporary | Within window area. | 25% of total window area. Allowed for display a maximum of 15 days at 1 time, up to 3 times in a 12-month period. |
viii. A-Boards and Other Portable Sidewalk Signs are Permitted | May not impede pedestrian flow. | 1 per business. Signs may only be permitted while the business is open. Requires an encroachment permit if in the public right-of-way. |
ix. Building Wall Facing RR ROW | Businesses may have signage equal to or less than the allowable projecting or wall sign standards. | Building or parcel must front along Crowther Avenue and the Railroad ROW |
x. Directional Signage on Private Property | ||
111 TRANSIT ORIENTED DEVELOPMENT PACKING HOUSE DISTRICT DEVELOPMENT STANDARDS
Table 1. Allowed Land Uses and Permit Requirements |
|---|
P – permitted |
UP – use permit |
NP – not permitted |
Land Use Type | Permit Requirement | Specific Use Regulations |
|---|---|---|
Recreation, Education, Public Assembly Uses | ||
1. Commercial recreation facility – indoor | NP | |
2. Conference/Convention Facility | NP | |
3. Health/Fitness Facility, including stand alone or roving fitness classes | NP | |
4. Library, Museum | P | Permitted only in the historic Packing House building.1 |
5. Park, Playground | P | Only permitted when integrated into the overall development of a site. |
6. School – specialized education, training | NP | |
7. Studio – art, dance, martial arts, music, cooking, fitness (such as yoga, Pilates, spin, etc.) | P | Permitted only above the ground floor within a mixed use development or above the ground floor of the Packing House building. Only one studio per development. |
8. Theatre (live performing arts) | P | Movie cinemas not permitted. |
Residential Uses | ||
9. Emergency Shelter | NP | |
10. Home Occupation | P | PMC Section 23.81.020. No additional parking shall be permitted for those units with home occupation. |
11. Live Work, in Packing House Building | P | |
12. Live Work | UP | |
13. Mixed Use Project with Residential | P | Maximum of 3 bedrooms per unit; 15% of all units may be up to 3 bedrooms. The design and construction of multifamily residential developments as courtyard housing projects is encouraged. Ground floors in mixed use projects must be plumbed/planned restaurant infrastructure including exhaust and grease control device. |
14. Multifamily Residential, Catalyst Site | UP | Maximum of 3 bedrooms per unit; 15% of all units may be up to 3 bedrooms. Project with only multifamily residential are permitted only on the “catalyst site.” See definition of “catalyst site.” |
15. Non Mixed Use Project with a parcel size under 20,000 square feet | UP | Must be commercial on ground floor. May also include commercial, residential or office above ground floor. Must meet all other development standards. Must meet the intent and purpose of this chapter. |
16. Residential Only | NP, except as permitted as a catalyst site as described in definitions. | |
Retail/Commercial Uses | ||
17. Accessory Retail or Services | P | Only permitted when primary commercial use is established. Must be incorporated into mixed-use or within Packing House; cannot stand alone. |
18. Adult Entertainment Facility or Business | NP Pursuant to PMC Ch. 23.89 | |
19. Alcoholic Beverage Sales (not associated with bar, brewery, distillery, restaurant, or neighborhood market or grocery) | NP | |
20. Antique or Collectible Store | P | Must be incorporated into mixed-use or within Packing House; cannot stand alone. |
21. Artisan Shop | P | Must be incorporated into mixed-use or within Packing House; cannot stand alone. |
22. Auto Repair or Auto Parts Sales | NP | |
23. Bar, Tavern, Brewery, Distillery, Tasting Rooms, Wine Cellar | UP | Must be incorporated into mixed-use or within Packing House; cannot stand alone. |
24. Neighborhood Market (without alcohol beverage sales) | P | With alcohol sales, a use permit is required. |
25. Drive-Through (any uses) | NP | |
26. Furniture, Furnishings and Appliance Store | NP | |
27. General Retail – less than 5,000 sf | P | Must be incorporated into mixed-use or within Packing House; cannot stand alone. |
28. General Retail –5,000 sf to 20,000 sf | UP | Must be incorporated into mixed-use or within Packing House; cannot stand alone. |
29. General Retail – more than 20,000 sf (max 60,000 sf) | NP | |
30. Groceries, Specialty Foods – 10,000 sf or less | P | With alcohol sales, a use permit is required. |
31. Groceries, Specialty Foods – more than 10,000 sf | UP | |
32. Medical Marijuana Facilities | NP Pursuant to PMC Ch. 23.46 | |
33. Nightclub (including comedy clubs) | UP | Must be incorporated into mixed-use or within Packing House; cannot stand alone. “Hostess” clubs are not permitted. |
34. Outdoor Dining | P | Permitted in public right-of-way with an encroachment permit. Pursuant to ABC requirements as well as the outdoor dining permit and guidelines. |
35. Outdoor Display and Sales | NP | May be permitted with a special event permit as part of a coordinated event, pursuant to PMC Section 23.81.015. No more than 4 a year. |
37. Restaurant with Alcohol Sales | UP | Must be incorporated into mixed-use or within Packing House; cannot stand alone. |
38. Restaurant | P | Must be incorporated into mixed-use or within Packing House; cannot stand alone. |
39. Secondhand/Thrift/Pawnshop/Charity Store | NP | |
40. Service Station | NP | |
41. Tobacco Sales, including electronic smoking devices | UP | |
Services – Business, Financial, Professional | ||
42. ATM | P | Must be integrated into building façade. Stand alone kiosks not permitted. |
43. Bank, over 2,000 sf | NP | Small banks of 2,000 sf or less are permitted. |
44. Medical Services | UP | See definition. May only be permitted on 2nd story of mixed-use development. |
45. Office | P | Upper floors; or in conjunction with live/work. Must be incorporated into mixed-use or within Packing House; cannot stand alone. May only be permitted on 2nd story of mixed-use development. |
Services – General | ||
46. Adult Daycare | NP | |
47. Commercial Daycare Center | NP | Large family daycare facilities not permitted. All child care facilities shall be integrated into the over development. |
48. Lodging – Bed and Breakfast | UP | Maximum of 10 beds allowed. Are not required to contain residential units or uses. |
49. Lodging – Hotel | UP | Are not required to contain residential units or uses. Permitted within 250 feet (verify) of freeway right-of-way. 1st floor must include 25—50% of floor area as retail or restaurant or conference area. Retail/restaurant uses must be consistent with mixed use standards. Must include conference center. |
50. Massage Establishments | UP Pursuant to PMC § 23.30.030 | |
51. Personal Services | P | Must be incorporated into mixed-use or within Packing House; cannot consist of a stand-alone use or building. May only be permitted on 2nd story of mixed-use development or Packing House. |
52. Public Safety Facility | NP | Except that city police department satellite stations are permitted. Satellite stations may not be stand alone facilities. |
53. Spa Services | UP | Must be incorporated into mixed-use or within Packing House; cannot stand alone. May only be permitted on 2nd story of mixed-use development. Must include a full suite of services. |
54. Spa Services with Alcohol | UP | Must be incorporated into mixed-use or within Packing House; cannot stand alone. May only be permitted on 2nd story of mixed-use development. Must include a full suite of services. |
55. Cigar or Hookah Lounge | UP | |
56. Meeting Halls, Banquet Centers (stand alone) | NP | |
57. Tattoo Parlors/Body Modification | UP | |
58. Hostess Bars | NP | |
Transportation, Communications & Infrastructure | ||
59. Broadcasting or Recording Studio | UP | Must be incorporated into mixed-use or within Packing House; cannot stand alone. May only be permitted on 2nd story of mixed-use development. |
60. Public Parking Structure | P | |
61. Transit Station or Terminal | P | |
62. Telecommunication Cell Tower | Pursuant to PMC Ch. 23.82 | |
Historic Packing House Building | ||
63. Adaptive Re-Use of Packing House Building. The building and property located at 341 S. Melrose Street is a local historic building and is listed on the California Register. As an historic building, it is eligible for adaptive re-use in order to preserve the historic elements and quality of the building and property. | UP, subject to an adaptive re-use plan prepared by a qualified preservation expert as deemed appropriate by the city. | Adaptive re-use plan may be reviewed for comment by the city of Placentia historical committee. The adaptive re-use of this building is not subject to any development standards contained in this chapter, however a finding must be made that the reuse plan meets and is consistent with the intent and purpose of this chapter. |
Notes: | |
|---|---|
1 | The Packing House Building is located at 341 S. Melrose Street. |
Table 2. Development Standards | ||
|---|---|---|
Standard | Notes | |
Architectural Review | ||
High quality, 360 degree, architectural and urban design is required. All new projects will require architectural review by a third party architectural expert, selected by the city. | Third party review costs are the responsibility of the applicant. | |
Building Placement Regulations | ||
1. Density | 65 dwelling unit/acre minimum and 95 dwelling units/acre maximum | Density shall be calculated using gross lot size, prior to any required right-of-way dedications. Dedications shall be required along Crowther Avenue. |
2. Block Length and Lot Size Requirements. Each project along Crowther Avenue shall create an active and inviting environment for pedestrians. | ||
a. Maximum Building Length without Breaks in Building Massing | 350 ft. | Breaks in building massing mean courtyards, plazas, outdoor dining, etc. These should be open from ground to sky and constitute a true break in the building massing. |
b. Lot Depth | No minimum lot depth | Integrated developments and lot consolidations are encouraged with lot orientation fronting on Crowther Avenue, and where possible, with parcels extending from Crowther to the railroad right-of-way. |
c. Minimum Lot Size | 20,000 square feet | |
3. Setbacks. Minimum setbacks required and, where noted, maximum setbacks established, except where a frontage type standard allows exceptions or establishes different requirements. Setbacks are measured from property line after any required dedications. Fire department requirements supersede any setback listed below. | ||
a. Setback From Railroad Track | 0 feet | 10 ft. from rear ROW preferred by BNSF for above ground structures. Applicants should consider access to rear portion of new development. |
b. Front Yard Setback | 3 ft. min./15 ft. max. | |
c. Side Yard Setback | 0 feet, or 10 ft. when adjacent to a property containing residential uses. | |
d. Rear Yard Setback | 10 ft. | |
e. Street Side Yard Setback | 5 ft. min./15 ft. max. | |
4. Projections | ||
a. Allowable Setback Projections. | ||
i. Ground Floor: | ||
• Awnings and canopies over windows: 60 inches; | ||
• Sun shade structures: 15 feet; | ||
• Bay windows: 60 inches (not wider than 10 feet); | ||
• Cornices, belt courses, and similar architectural features: 12 inches; | ||
• Eaves, roof overhangs: 30 inches; and | ||
• Uncovered porches, decks and landings (may be covered by arbors or trellises): 10 feet. | ||
ii. Above Ground Floor. Awnings, galleries, balconies, bay windows: 48 inches. | ||
iii. Art, as determined by the approval of the public art component of the project. | ||
iv. For signs, see Sign Regulations, § 23.110.050. | ||
v. All projections must maintain a minimum of 8 feet vertical height from ground. | ||
b. Public right-of-way encroachments require approval of an encroachment permit. | ||
5. Building Height, Rooftop Amenities, Frontages, and Ground Floor | ||
a. Building Height | 3 stories minimum, 35 ft. minimum, 5 stories maximum, not to exceed 68 ft. | |
b. Frontage Requirements. In order to support the pedestrian environment, building frontages onto streets and open spaces shall be maximized. No visible parking is permitted along frontages. A minimum of 75% of the site frontage shall be occupied as building frontage. A section of blank wall shall not exceed 20 linear feet without being interrupted by a window or entry or other façade treatment. | ||
c. Where commercial uses are required on ground floors, those commercial uses shall have a minimum 15 ft. floor to ceiling height. | ||
6. Provision of Common Open Space (Residential Portion Only) | ||
a. Amount per residential use | 50 sf/unit for residential units; 50 sf/unit for 5 or more live work units. | Up to 75% of this requirement can be fulfilled by providing a public plaza in lieu of private common open space. |
b. Types of Common Open Space Permitted | • Common open space can be active or passive but must be accessible to all non-residential tenants (i.e., employees and employers) and residential residents. | |
• Required setbacks may not be counted as common open space, except that rear yards counted as meeting the requirement for live/work units. | ||
• Common open space shall be fully landscaped and requires an approved landscape plan. | ||
• Examples may include: courtyards, clubhouses with accompanying landscaped areas, swimming pools, plazas, greens, parks, playgrounds, picnic areas, outdoor seating. | ||
c. Rooftop Amenities | Rooftop amenities are permitted if they provide additional recreational or common open space activities for the residents of the building. | |
• 50% of the rooftop amenities (structures and active recreation amenities) may count towards the square footage requirement for either private or common open space. | ||
• Rooftop amenities, such as and not limited to, clubhouses, swimming pools, tennis courts, open space areas, fitness centers, are permitted to project 16 ft. above the maximum height limit if integrated into the overall design of the project and the maximum rooftop building coverage is limited to 30% of the rooftop floor area. | ||
• Roof top amenities shall be set back from the building edge such that no more than 20% of the rooftop structure can be visible from the primary public right-of-way at centerline of the street. | ||
• Rooftop amenities are intended for the use of building residents. | ||
d. Courtyard Common Open Space Requirements | Courtyards shall be designed as a central courtyard or as partial, multiple, separated or interconnected courtyards. | |
• Minimum courtyard dimension shall be 40 ft. when the long axis of the courtyard is oriented EW and 30 ft. for a NS orientation. The courtyard proportion is 1:1 between its width and height for at least 2/3 of the court’s perimeter. As long as total open space requirement is met, this ratio could be modified by up to 10%. | ||
• When there are 2 or more courtyards, they shall be connected to each other. | ||
• The area required for first level patios shall not be deducted from the overall courtyard area. | ||
7. Provision of Private Open Space (Residential Portion Only) | ||
a. Live Work | 64 sf/unit | 6 ft. min. in any direction; the total of 64 sf must be provided as 1 private open space area, not broken up into smaller sizes. |
b. Residential-Attached & Multifamily | 64 sf/unit | 6 ft. min. in any direction; the total of 64 sf must be provided as 1 private open space area, not broken up into smaller sizes. |
8. Parking | Standards | Applicable Land Uses |
a. Retail – spaces per 1,000 sf | 2 min./4 max. | Accessory retail, antique, artisan, general retail, grocery, retail complex, personal services |
b. Eating and Drinking Establishments – spaces per 1,000 sf | 5 min./10 max. | Bar/tavern, restaurant, brewery, etc. |
c. Outdoor Dining on Private Property | 0 | • Outdoor dining is encouraged and shall be incorporated as part of the overall design of the building or project. • Outdoor dining may project into required setbacks. |
• No parking is required for outdoor dining unless the total outdoor dining square footage is greater than the total interior dining area. In this circumstance, project must provide parking for the amount over the interior square footage. • Acceptable barriers for defining outdoor dining areas shall include fences, railings, and planter boxes. | ||
d. Specialty Goods & Foods– spaces per 1,000 sf | 2 min./4 max. | |
e. Entertainment & Recreation – spaces per 1,000 sf | 6 min./10 max. | Health/fitness, playgrounds, studios, theatres cannot be stand alone. |
f. Commercial Goods – spaces per 1,000 sf | 2 min./4 max. | |
g. Civic & Cultural, including Libraries and Museums – spaces per 1,000 sf | 3 min./no max. | |
h. Office Professional – spaces per 1,000 sf | 2 min./4 max. | |
i. Personal Services | 3 min./no max. | |
j. Live Work | 1 min./1.5 max. | |
k. ATM | 0 | |
l. Lodging – B&B | 1 per sleeping room. | No assembly space permitted. |
m. Lodging – Hotel | 1 per sleeping room, plus 1 space for every 75 sf of assembly area. | |
Residential | ||
n. Spaces per studio unit | 1 min./1 max. | |
o. Spaces per 1 bed unit | 1 min./1.5 max. | |
p. Spaces per 2 bed unit | 1.5 min./2 max. | |
q. Spaces per 3 bed unit | 2 min./2.5 max. | |
r. Guest spaces per 10 units | 2 min./3 max. | |
s. Mixed Use | Parking shall meet the requirements for individual land uses. Residential parking shall be separated from non-residential parking and easily accessible through a controlled mechanism. | Reduced parking may be permitted through a parking study. |
Other | ||
t. Bike Parking – Short-Term | Residential: 1 resident bicycle parking space for every 5 residential units, or portion thereof; Nonresidential: 1 bicycle parking space for every 5,000 sf, or portion thereof, of nonresidential floor area. | |
u. Bike Parking – Long-Term | Residential: 2 bicycle storage units for every 5 dwelling units for the first 20, and 1 for every 5 additional units, or portion thereof; Nonresidential: Any establishment with a parking structure and a minimum of 10,000 sf of nonresidential space shall provide long-term bicycle parking at a minimum ratio of 1 space per 20 vehicle spaces. | |
v. Electric Vehicle Charging Stations. | Minimum 10% of project’s parking spaces must provide EV Level 2 charging stations. Alternatively, 5% of total spaces if installing DC fast charging stations. | |
w. Transit Station or Terminal. | As per director of development services in coordination with transportation authority. | |
x. Telecommunication Facility | 1 space to service facility. | |
y. Surface Parking. | Surface parking is permitted as long as not visible from public street and is fully landscaped and screened from public view. | |
z. Parking Structure. | Structure parking permitted only if integrated into overall design of building and “wrapped” with the building, such that the parking area is not visible from any portion of the front, sides, rear or interior courtyards of the project. | |
aa. Podium Parking. | Permitted if fully integrated into a development with a “wrapped” parking structure. | |
bb. Underground Parking. | Permitted if fully integrated into the design of the development. | |
cc. Parking Reduction. | Applicants may apply for parking reduction before the planning commission for residential and mixed use projects up to a maximum reduction of 25% through a parking demand study or shared parking analysis. One such incentive could include a Zip car or shared car plan. | |
Table 3. Sign Standards by Use | |||
|---|---|---|---|
Multi-Family Residential Use | |||
Allowed Sign | Maximum Sign Height | Maximum No. of Signs Allowed per Parcel | Maximum Sign Area Allowed per Parcel |
i. Wall or Freestanding | Wall signs: below edge of roof. Freestanding: 48″ | 1 wall sign or freestanding sign per entrance or street frontage. | 12 sf each per face area; 24 sf maximum total sf for all signs. |
Nonresidential Use/Mixed Use | ||
|---|---|---|
Allowed Sign | Placement Standards | Maximum Number and Sign Area |
i. Awning | Shall be entirely on awning valence; lettering max 66% of valence height; valence height max: 18″. | 50% of the area of the valence front. 1 sign max per each separate awning valence. |
ii. Marquee | To be established during project review. Allowed only for the entrance of a theatre or playhouse. | To be established during project review. 1 sign max. |
iii. Monument | 5 ft. including base structure. Allowed only on a site with more than 100 ft. of continuous street frontage. | 36 sf |
iv. Projecting or Suspended | 16″ from face of building and bottom of sign shall be no closer than 8 ft. above sidewalk surface below. | 6 sf. No dimension greater than 3 ft. Sign shall be redwood sandblasted, hand carved or architecturally designed. |
v. Wall | 2 ft. below parapet or eave. Individual letters 18″. Mounting 1-story: above 1st floor windows. Mounting multi-story: between windows. | 1 sf per linear foot primary business. 1 sign allowed per business frontage with pedestrian entrance. Side street or rear entrance wall sign max 50% of the primary sign area. |
vi. Window Permanent | Within window area. | 15% of total window area max. |
vii. Window Temporary | Within window area. | 25% of total window area. Allowed for display a maximum of 15 days at 1 time, up to 3 times in a 12-month period. |
viii. A-Boards and Other Portable Sidewalk Signs are Permitted | May not impede pedestrian flow. | 1 per business. Signs may only be permitted while the business is open. Requires an encroachment permit if in the public right-of-way. |
ix. Building Wall Facing RR ROW | Businesses may have signage equal to or less than the allowable projecting or wall sign standards. | Building or parcel must front along Crowther Avenue and the Railroad ROW |
x. Directional Signage on Private Property | ||