112 OLD TOWN PLACENTIA REVITALIZATION PLAN DEVELOPMENT STANDARDS
Table 1. Allowed Land Uses and Permit Requirements |
|---|
P – permitted |
UP – use permit |
NP – not permitted |
Permit Requirement | Planning Subareas | Notes And Special Use | ||||
|---|---|---|---|---|---|---|
Main Street | Village | Mixed-Use (1) | High-Density Residential | Public Facility | Regulations | |
Recreation, Education, Public Assembly Uses | ||||||
1. Commercial Recreation Facility, Indoor | NP | NP | NP | NP | NP | |
2. Community Recreation Facility | NP | NP | NP | NP | NP | |
3. Conference/ Convention Facility | NP | NP | NP | NP | NP | |
4. Health/Fitness Facility, including stand alone or roving fitness classes | NP | UP | UP | NP | NP | |
5. Library, Museum | NP | UP | NP | NP | NP | |
6. Public Park, Playground or Plaza | P | P | P | P | P | |
7. School – specialized education, training | NP | NP | NP | NP | NP | |
8. Studio – art, dance, martial arts, music, photography, cooking, instructional, fitness (such as yoga, Pilates, spin, etc.) | UP | UP | UP | NP | NP | Not to exceed 1,500 square feet |
9. Theatre (live performing arts, live music) | UP | UP | UP | NP | NP | Movie cinemas only permitted in mixed use. |
Residential Uses | ||||||
1. Emergency/Transitional Shelter | NP | NP | NP | NP | NP | |
2. Home Occupation | NP | P | P | P | NP | Not permitted in ground floor units, must comply with home occupation provisions of PMC. |
3. Live Work | NP | UP | NP | NP | NP | |
4. Multifamily Residential, new construction only, maximum of 29 du/ac | UP (only permitted above the second floor) | UP (upper floors only) | UP (upper floors only) | NP | NP | See definition of “new construction.” |
5. Multifamily Residential, new construction only, minimum of 30 du/ac | NP | UP (upper floors only) | UP (upper floors only) | P (by right) | NP | By right developments must meet: • The purpose and intent of this chapter as well as all standards. • All zoning code regulations. • All city policies. • Requires review by the planning & development ad hoc committee. • All existing and future design guidelines. |
6. Assisted Living Facility | NP | NP | NP | NP | NP | |
7. Single-Family or Duplex Residential, new | NP | NP | NP | NP | NP | Only permitted in the R-2 overlay zone. Pursuant to Ch. 23.15 of the municipal code. |
8. Existing Residential Uses Fronting on Main and Alta Streets | P | P | NP | NP | NP | Only permitted in the R-2 overlay zone. Pursuant to Ch. 23.15 of the municipal code. |
9. Mixed Use Development | UP (only permitted above the second floor) | UP | UP | NP | NP | |
Retail/Commercial Uses (2) | ||||||
1. New Ground Floor Residential and Office Uses in R-2 Overlay Zone | UP | UP | NA | NA | NA | 50% of the lot depth, measured from Alta or Main, must be either residential or office along Alta and Main. The rear 50%, facing the alley, may be any other use permitted in the subarea. |
2. Accessory Retail or Services | P | P | P | NP | NP | Only permitted when primary commercial use is established. Must be incorporated into mixed-use; cannot stand alone. |
3. Adult Entertainment Facility or Business | NP | NP | NP | NP | NP | Pursuant to PMC Ch. 23.89 |
4. Liquor Stores/Alcoholic Beverage Sales (not associated with bar, brewery, distillery, restaurant, or neighborhood market or grocery) | NP | NP | NP | NP | NP | |
5. Antique or Collectible Store | P | P | P | NP | NP | |
6. Artisan/Handcraft Shop | P | P | P | NP | NP | |
7. Auto Repair, Auto Sales or Auto Parts Sales | NP | NP | NP | NP | NP | |
8. Bar, Tavern, Brewery, Distillery, Tasting Rooms, Wine Cellar | UP | UP | UP | NP | NP | |
9. Drive-Through (any uses) | NP | NP | NP | NP | NP | |
10. General Retail – less than 5,000 sf | P | P | P | NP | NP | |
11. General Retail –5,000 sf to 20,000 sf | UP | UP | UP | NP | NP | |
12. General Retail – more than 20,000 sf (max 60,000 sf) | NP | NP | NP | NP | NP | |
13. Groceries, Specialty Foods – 10,000 sf or less | P | P | P | NP | NP | With alcohol sales, a use permit is required. |
14. Groceries, Specialty Foods – more than 10,000 sf | UP | UP | UP | NP | NP | |
15. Medical Marijuana Facilities | NP | NP | NP | NP | NP | Pursuant to PMC Ch. 23.46 |
16. Neighborhood Market (without alcohol beverage sales) – 10,000 sf or less | P | P | P | NP | NP | With alcohol sales, a use permit is required. |
17. Nightclub | UP | UP | UP | NP | NP | |
18. Outdoor Dining | P | P | P | NP | NP | Permitted in public right-of-way with an encroachment permit. Pursuant to ABC requirements as well as the city’s outdoor dining permit and guidelines. |
19. Outdoor Display and Sales | NP | NP | NP | NP | NP | May not encroach into public right-of-way. |
20. Pet Store, Pet Boarding, Animal Shelter | UP | UP | UP | NP | NP | Sheltering and boarding shall require a use permit. |
21. Restaurant | P | P | P | NP | NP | |
22. Restaurant with Alcohol Sales | UP | UP | UP | NP | NP | |
23. Secondhand/Thrift/ Consignment/Pawn/Charity Store | UP | UP | UP | NP | NP | |
24. Service Station | NP | NP | NP | NP | NP | |
25. Tobacco Sales, including Electronic Smoking Devices | UP | UP | UP | NP | NP | |
Services – Business, Financial, Medical, Professional | ||||||
1. ATM | P | P | P | NP | NP | Must be integrated into building façade. Stand alone kiosks not permitted. |
2. Bank (2,000 sf or less) | P | P | P | NP | NP | Banks over 2,000 sf are not permitted. |
3. Business Support Services (copying, printing, office supplies, etc.) | P | P | P | NP | NP | |
4. Hospital | NP | NP | NP | NP | NP | |
5. Medical Office | P | P | P | NP | NP | See definition. Only permitted on upper floors, except in R-2 overlay. |
6. Office | P | P | P | NP | P | See definition. Only permitted on upper floors except in R-2 overlay. |
Services – General | ||||||
1. Adult Daycare | NP | NP | NP | NP | NP | |
2. Cigar or Hookah Lounge | UP | UP | UP | NP | NP | |
3. Commercial Daycare Center | UP | UP | UP | NP | NP | |
4. Hostess Bars | NP | NP | NP | NP | NP | |
5. Laundromat and Laundry Services | UP | UP | UP | NP | NP | |
6. Lodging – B&B | UP | UP | NP | NP | NP | |
7. Lodging – Hotel | UP | UP | UP | NP | NP | |
8. Massage Establishments | UP | UP | UP | NP | NP | Not permitted on the ground floor in any subarea. Pursuant to PMC § 23.30.030 |
9. Meeting Halls, Banquet Centers (Stand alone) | NP | NP | NP | NP | NP | |
10. Personal Services | P | P | P | NP | NP | |
11. Public Safety Facility | NP | NP | NP | NP | P | |
12. Spa Services (with or without alcohol) | UP | UP | UP | NP | NP | |
13. Tattoo Parlors/Body Modification | UP | UP | UP | NP | NP | |
Transportation, Communications & Infrastructure | ||||||
1. Broadcasting or Recording Studio | UP | UP | UP | NP | NP | May only be permitted on upper floors of mixed-use development. |
2. Public Parking Structure or Surface Parking Lot | UP | UP | UP | UP | P | |
3. Transit Station or Terminal | NP | NP | NP | NP | NP | |
4. Telecommunication Cell Tower/Microcell and Small Cell Sites | Pursuant to PMC Ch. 23.82 | |||||
Notes: | |
|---|---|
(1) | See Section 25.112.050, Development standards, for frontage requirements regarding building located at 102 S. Bradford Ave. |
(2) | Within the R-2 overlay zone, no retail or commercial uses are permitted on the ground floor. |
Table 2. Development Standards | ||||||
|---|---|---|---|---|---|---|
Development Standard | Planning Subareas | Notes and Additional Requirements | ||||
Main Street | Village | Mixed-Use | High-Density Residential | Public Facility | ||
Residential Density | ||||||
1. Density (max du/ac) | 25 | 35 | 55 | 65 | NA | Density shall be calculated using gross lot size, prior to any required right-of-way dedications. |
Setbacks. Minimum setbacks required and, where noted, maximum setbacks established, except where a frontage type standard allows exceptions or establishes different requirements. Setbacks are measured from property line after any required dedications. Fire department requirements supersede any setback listed below. | ||||||
1. Setback from Railroad Track | NA | NA | NA | 0 ft. | 0 ft. | 10′ from rear ROW preferred by BNSF for above ground structures. Applicants should consider access to rear portion of new development. |
2. Front Yard Setback (min-max) | 0 ft. | 0-5 ft. | 5-15 ft. | 5-15 ft. | NA | All setback areas facing a street or alley not devoted to walkways and driveways shall be properly landscaped and maintained in compliance with PMC Ch. 23.77. In the R-2 overlay zone, the front yard setback shall be 15′. |
3. Front Yard Setback for “through lots” and cross-alley developments in the R-2 overlay, fronting Alta and Main. See definitions section. | 15 ft. | 15 ft. | 15 ft. | NA | NA | |
4. Side Yard Setback | 0 ft. | 0 ft. | 0 ft. | 0 ft. | NA | |
5. Side Yard Setback for “through lots” and cross-alley developments in the R-2 overlay, fronting Alta and Main. See definitions section. | 0-5 ft.* | 0-5 ft.* | NA | 0 ft. | NA | *Less than 5′ setback adjoining an R-2 use requires approval from adjoining property owner of said R-2 use. |
6. Rear Yard Setback (min-max) | 0-15 ft. | 0-15 ft. | 0-15 ft. | 0 ft. | NA | |
7. Street Side Yard Setback (minmax) | 0 ft. | 0-5 ft. | 5* ft. | 5-15 ft. | NA | *Refers to Chapman Avenue setback. |
Projections and Encroachments | ||||||
1. Allowable Setback Projections | a. Ground Floor: i. Awnings and canopies over windows: 60″; ii. Barriers for defining outdoor dining areas such as fences, railings, planter boxes: as needed to encompass outdoor dining area; iii. Sun shade structures: 15′; iv. Bay windows: 60″ (not wider than 10′); v. Cornices, belt courses, and similar architectural features: 12″; vi. Eaves, roof overhangs: 30″; and vii. Uncovered porches, decks and landings (may be covered by arbors or trellises): 10′. b. Above Ground Floor. Awnings, galleries, balconies, bay windows: 48″ c. Art, as determined by the approval of the public art component of the project. d. For signs, see sign regulations, § 23.112.070. e. All projections must maintain a minimum of 8′ vertical clearance from ground. | |||||
2. Public Right-of-Way Encroachments (all require approval of an encroachment permit) | a. Art, as determined by the approval of the public art component of the project. b. For signs, see sign regulations, § 23.111.070. c. Outdoor dining is allowed by approval of the director of development services and director of public works or their designees and may require Alcoholic Beverage Control Board (ABC) approval. Approval is pursuant to the outdoor dining permit and guidelines. | |||||
Heights, Rooftop Amenities, Frontages, Lot Sizes | ||||||
1. Building Height | 2-Story Area: 2 stories, 30′ 3-Story Area: 3 stories, 40′ 4-Story Area: 4 stories, 55′ | 2 min/3 max stories, 40′ | 3 min/4 max stories, 60′ | 3 min/4 max stories, 55′ | 5 stories, 65′ | See “Old Town zoning map” for height subareas. New stories built on top of existing buildings shall be fully integrated into the design of the existing building. |
2. Minimum Lot Size required for a development at or over 3 stories. | 0 | 8,000 sf* | 10,000 sf | 10,000 sf | 0 | *Developments on lots smaller than 8,000 sf can be considered if they are contiguous to parcels with proposed or approved new developments and are developed with a zero lot line scenario or similar concept. The development on the smaller lot must complement and enhance the contiguous development and further the goals of this chapter. |
3. Ground Floor Height measured from finished floor to ceiling (min) | 15 ft. | 15 ft. | 15 ft. | NA | NA | |
4. Frontage Requirements | In order to support the pedestrian environment, building frontages onto streets and open spaces shall be maximized. No visible parking is permitted along frontages. A minimum of 75% of the site frontage shall be occupied as building frontage. A section of blank wall shall not exceed 20 linear feet without being interrupted by a window or entry or other façade treatment. | |||||
5. Rooftop Amenities | In multifamily residential and mixed-use residential projects, rooftop amenities, such as and not limited to, clubhouses, swimming pools, tennis courts, open space areas, fitness centers, are permitted to project 16′ above the maximum height limit if integrated into the overall design of the project and the maximum rooftop building coverage is limited to 30% of the rooftop floor area. Rooftop amenities shall be set back from the building edge such that no more than 20% of the rooftop structure can be visible from the primary public right-of-way at centerline of the street. Rooftop amenities are intended for the use of building residents. Rooftop amenities do not count as a “story” or “floor.” | |||||
6. Height Exceptions | Non-habitable building features such as chimneys (up to 6′ in width), cupolas, flagpoles, monuments, steeples, roof screens, equipment, and similar structures, covering no more than 10% of the top floor roof area to which they are accessory, may exceed maximum permitted height standards by up to 8′. | |||||
7. Building Orientation | New commercial or mixed use construction must orient the principal façade onto Bradford, Santa Fe or Chapman Avenue or Walnut Avenue. In the mixed use subarea, new buildings must be oriented toward Bradford and Chapman. | NA | NA | |||
8. Building Façade for building located at 102 S. Bradford Avenue (at Chapman) | The building façade of this building shall be preserved and integrated into the new design of any new development proposed on this site. This includes the façade along Bradford Ave (including the tower and the front section containing the large round window opening) and up to and including the façade (containing the stained glass windows) along Chapman Avenue. The Chapman Avenue façade preservation can end at the point where the planes of the two sections of that façade meet (where the east/west oriented portion of the building meets the north/south oriented portion of the building). The preservation does not necessarily have to include the small vestibule. The proposed architectural design of any new development shall be reviewed by a preservation architect; the selection of such preservation expert shall be approved by the city. | |||||
Provision of Common Open Space (Residential Only) | ||||||
1. Amount per Residential Use | a. 50 sf/unit for residential units; b. 50 sf/unit for 5 or more live work units. | |||||
2. Types of Common Open Space Permitted | a. Common open space can be active or passive but must be accessible to all nonresidential tenants (i.e., employees and employers) and residential residents. b. Required setbacks may not be counted as common open space. c. Common open space shall be fully landscaped and requires an approved landscape plan. d. Examples may include: courtyards, clubhouses with accompanying landscaped areas, swimming pools, plazas, greens, parks, playgrounds, picnic areas, outdoor seating. | |||||
3. Rooftop Amenities | 1. Rooftop amenities are permitted if they provide additional recreational or common open space activities. 2. Amenities, such as and not limited to, clubhouses, swimming pools, tennis courts, open space areas, fitness centers, are permitted to project 16′ above the maximum height limit if integrated into the overall design of the project and the maximum rooftop building coverage is limited to 30% of the rooftop floor area. Roof top amenities shall be set back from the building edge such that no more than 20% of the rooftop structure can be visible from the primary public right-of-way at centerline of the street. Rooftop amenities are intended for the use of building residents. 3. 50% of the rooftop amenities (structures and active recreation amenities) may count towards the square footage requirement for either private or common open space. 4. Rooftop buildings supporting recreational activities may cover a maximum of 30% of the rooftop area and may project above the maximum height limit by 16′. | |||||
4. Courtyard and Common Open Space Requirements | 1. Courtyards shall be designed as a central courtyard or as partial, multiple, separated or interconnected courtyards. 2. Minimum courtyard dimension shall be 40′ when the long axis of the courtyard is oriented EW and 30′ for a NS orientation. The courtyard proportion is 1:1 between its width and height for at least 2/3 of the court’s perimeter. As long as total open space requirement is met, this ratio could be modified by up to 10%. 3. When there are 2 or more courtyards, they shall be connected to each other. | |||||
Provision of Private Open Space (Residential and Live/Work Only) | ||||||
Amount per Residential Unit | 64 sf/unit | 6′ min. in any direction; the total of 64 sf must be provided as one private open space area, not broken up into smaller sizes. | ||||
Shopfronts | ||||||
The following are specific guidelines for shopfronts in the Old Town area: 1. 12′ to 16′ tall, as measured from the adjacent sidewalk. 2. The corresponding storefront(s) opening(s) along the primary frontage shall comprise 65% of the 1st floor wall area facing the street and not have opaque, stucco or reflective glazing. 3. Storefronts may be recessed from the frontage line by up to 10′. 4. “Bulkheads,” which are a segment of wall that transitions between the window opening(s) and the adjacent grade, are also encouraged. The bulkhead shall be between 24″ and 36″ tall (aluminum storefront or spandrel panel may not substitute for a bulkhead). | ||||||
Architectural Styles | ||||||
1. Main Street Commercial Multi-story façades are typically divided into base, body and top with the ground floor taller than the shorter upper floor which is finished by a significant parapet. The ground floor has recessed entries and any expansive glass is interrupted by structural columns with transoms to allow light to penetrate deep into the interior. Upper floor windows are smaller with vertical windows directly relating to the ground floor openings. | Style of architecture required in Main Street subareas | |||||
2. Mission Revival Prominent features of the style include red clay tile roofs, use of balconies, smooth-stuccoed exterior walls usually painted white, arched openings, colorful tile work and elaborate landscaping. The buildings frequently have courtyards. | Choices of architecture for the following: • Village subarea • Mixed use subarea • High density residential subarea | |||||
3. Spanish Colonial Typical features include a low-pitched roof with little or no eave overhang, a red-tiled roof, perhaps a prominent rounded arch over a door, window or porch, a stucco wall surface, and usually an asymmetrical façade. The features elaborate molded ornament around doors and windows, polychrome tile at ingresses and wrought iron grilles and balconies. | This style of architecture permitted only in high density residential subarea | |||||
Table 3. Parking Standards | ||
|---|---|---|
Parking Standards | Standards | Applicable Land Uses |
Nonresidential | ||
Retail – spaces per 1,000 sf | 2 min./4 max. | Accessory retail, antique, artisan, bank, business support services, general retail, grocery, retail complex, personal services, pet store/boarding. |
Eating and Drinking Establishments – spaces per 1,000 sf | 5 min./10 max | Bar/tavern, restaurant, brewery, etc. |
Outdoor Dining | 0 | Provided the outdoor dining area does not exceed the interior dining area. Any square footage over the interior dining area shall provide parking pursuant to the eating and drinking establishment requirement above. |
Specialty Goods & Foods – spaces per 1,000 sf | 2 min./4 max. | |
Entertainment & Recreation – spaces per 1,000 sf | 6 min./10 max. | Health/fitness, recreation, playgrounds, studios, theatres cannot be stand alone. |
Commercial Goods – spaces per 1,000 sf | 2 min./4 max. | |
Civic & Cultural, including libraries, museums – spaces per 1,000 sf | 3 min./no max. | |
Office Professional – spaces per 1,000 sf | 2 min./4 max. | |
Personal Services | 3 min./no max. | |
Live Work | 1 min./1.5 max. | |
ATM | 0 | |
Lodging – Bed & Breakfast | 1 per sleeping room. | No assembly space permitted. |
Lodging – Hotel | 1 per sleeping room, plus 1 space for every 75 sf of assembly area. | |
Residential | ||
Spaces per studio unit | 1 min./1 max. | |
Spaces per 1 bed unit | 1 min./1.5 max. | |
Spaces per 2 bed unit | 1.5 min./2 max. | |
Spaces per 3 or more bed unit | 2 min./2.5 max. | |
Guest spaces per 10 units | 2 min./3 max. | |
Mixed-Use | ||
Mixed Use | Parking shall meet the requirements for individual land uses. Residential parking shall be separated from nonresidential parking and easily accessible through a controlled mechanism. | Reduced parking may be permitted through a parking study. |
Other | ||
Transit Station or Terminal | As per director of development services in coordination with transportation authority. | |
Telecommunication Facility, Small/Micro Cell Sites | 1 space to service facility. | |
Table 4. Sign Standards by Use | |||
|---|---|---|---|
Multifamily Residential Use | |||
Allowed Sign | Maximum Sign Height | Maximum No. of Signs Allowed per Parcel | Maximum Sign Area Allowed per Parcel |
1. Wall or Freestanding | Wall signs: below edge of roof. Placement shall only be located below the roof or over the primary entrance. Freestanding: 48 in. | 1 wall sign or freestanding sign per entrance or street frontage | 12 sf each per face area; 24 sf maximum total sf for all signs. |
1. Awning | Shall be entirely on awning valance; lettering max 66% of valance height; valance height max: 18 in. | 50% of the area of the valance front. 1 sign max per each separate awning valance. | 1. Awning |
2. Marquee | To be established during project review. Allowed only for the entrance of a theatre or playhouse. | To be established during project review. 1 sign max | 2. Marquee |
Nonresidential Use/Mixed-Use | ||
|---|---|---|
Allowed Sign | Placement Standards | Maximum Number and Sign Area |
3. Monument | 5 ft. including base structure. Allowed only on a site with more than 100 ft. of continuous street frontage. | 36 sf |
4. Projecting or Suspended | 16 inches from face of building and bottom of sign shall be no closer than 8 ft. above sidewalk surface below. | 6 sf. No dimension greater than 3 ft. Sign shall be redwood sandblasted, hand carved or architecturally designed. |
5. Wall | 2 ft. below parapet or eave. Individual letters 18 inches. | 1 sf. per linear foot primary business. |
Mounting 1-story: above 1st floor windows. | 1 sign allowed per business frontage with pedestrian entrance. | |
Mounting multi-story: between windows. | Side street or rear entrance wall sign max 50% of the primary sign area. | |
6. Window Permanent | Within window area | 15% of total window area max. |
7. Window Temporary | Within window area | 25% of total window area. Allowed for display a maximum of 15 days at 1 time, up to 3 times in a 12-month period. |
8. A-Boards and other Portable Sidewalk Signs are permitted | May not impede pedestrian flow. | 1 per business. Signs may only be permitted while the business is open. Requires an encroachment permit if in the public right-of-way and a creative sign permit. |
9. Building Wall Facing RR ROW | Businesses may have signage equal to or less than the allowable projecting or wall sign standards. | Building or parcel must front along Crowther Avenue and the Railroad ROW. |
10. Directional Signage on Private Property | Cannot be freestanding and shall be minimized for basic directional functions. | Included in sign permit application approval process. |
112 OLD TOWN PLACENTIA REVITALIZATION PLAN DEVELOPMENT STANDARDS
Table 1. Allowed Land Uses and Permit Requirements |
|---|
P – permitted |
UP – use permit |
NP – not permitted |
Permit Requirement | Planning Subareas | Notes And Special Use | ||||
|---|---|---|---|---|---|---|
Main Street | Village | Mixed-Use (1) | High-Density Residential | Public Facility | Regulations | |
Recreation, Education, Public Assembly Uses | ||||||
1. Commercial Recreation Facility, Indoor | NP | NP | NP | NP | NP | |
2. Community Recreation Facility | NP | NP | NP | NP | NP | |
3. Conference/ Convention Facility | NP | NP | NP | NP | NP | |
4. Health/Fitness Facility, including stand alone or roving fitness classes | NP | UP | UP | NP | NP | |
5. Library, Museum | NP | UP | NP | NP | NP | |
6. Public Park, Playground or Plaza | P | P | P | P | P | |
7. School – specialized education, training | NP | NP | NP | NP | NP | |
8. Studio – art, dance, martial arts, music, photography, cooking, instructional, fitness (such as yoga, Pilates, spin, etc.) | UP | UP | UP | NP | NP | Not to exceed 1,500 square feet |
9. Theatre (live performing arts, live music) | UP | UP | UP | NP | NP | Movie cinemas only permitted in mixed use. |
Residential Uses | ||||||
1. Emergency/Transitional Shelter | NP | NP | NP | NP | NP | |
2. Home Occupation | NP | P | P | P | NP | Not permitted in ground floor units, must comply with home occupation provisions of PMC. |
3. Live Work | NP | UP | NP | NP | NP | |
4. Multifamily Residential, new construction only, maximum of 29 du/ac | UP (only permitted above the second floor) | UP (upper floors only) | UP (upper floors only) | NP | NP | See definition of “new construction.” |
5. Multifamily Residential, new construction only, minimum of 30 du/ac | NP | UP (upper floors only) | UP (upper floors only) | P (by right) | NP | By right developments must meet: • The purpose and intent of this chapter as well as all standards. • All zoning code regulations. • All city policies. • Requires review by the planning & development ad hoc committee. • All existing and future design guidelines. |
6. Assisted Living Facility | NP | NP | NP | NP | NP | |
7. Single-Family or Duplex Residential, new | NP | NP | NP | NP | NP | Only permitted in the R-2 overlay zone. Pursuant to Ch. 23.15 of the municipal code. |
8. Existing Residential Uses Fronting on Main and Alta Streets | P | P | NP | NP | NP | Only permitted in the R-2 overlay zone. Pursuant to Ch. 23.15 of the municipal code. |
9. Mixed Use Development | UP (only permitted above the second floor) | UP | UP | NP | NP | |
Retail/Commercial Uses (2) | ||||||
1. New Ground Floor Residential and Office Uses in R-2 Overlay Zone | UP | UP | NA | NA | NA | 50% of the lot depth, measured from Alta or Main, must be either residential or office along Alta and Main. The rear 50%, facing the alley, may be any other use permitted in the subarea. |
2. Accessory Retail or Services | P | P | P | NP | NP | Only permitted when primary commercial use is established. Must be incorporated into mixed-use; cannot stand alone. |
3. Adult Entertainment Facility or Business | NP | NP | NP | NP | NP | Pursuant to PMC Ch. 23.89 |
4. Liquor Stores/Alcoholic Beverage Sales (not associated with bar, brewery, distillery, restaurant, or neighborhood market or grocery) | NP | NP | NP | NP | NP | |
5. Antique or Collectible Store | P | P | P | NP | NP | |
6. Artisan/Handcraft Shop | P | P | P | NP | NP | |
7. Auto Repair, Auto Sales or Auto Parts Sales | NP | NP | NP | NP | NP | |
8. Bar, Tavern, Brewery, Distillery, Tasting Rooms, Wine Cellar | UP | UP | UP | NP | NP | |
9. Drive-Through (any uses) | NP | NP | NP | NP | NP | |
10. General Retail – less than 5,000 sf | P | P | P | NP | NP | |
11. General Retail –5,000 sf to 20,000 sf | UP | UP | UP | NP | NP | |
12. General Retail – more than 20,000 sf (max 60,000 sf) | NP | NP | NP | NP | NP | |
13. Groceries, Specialty Foods – 10,000 sf or less | P | P | P | NP | NP | With alcohol sales, a use permit is required. |
14. Groceries, Specialty Foods – more than 10,000 sf | UP | UP | UP | NP | NP | |
15. Medical Marijuana Facilities | NP | NP | NP | NP | NP | Pursuant to PMC Ch. 23.46 |
16. Neighborhood Market (without alcohol beverage sales) – 10,000 sf or less | P | P | P | NP | NP | With alcohol sales, a use permit is required. |
17. Nightclub | UP | UP | UP | NP | NP | |
18. Outdoor Dining | P | P | P | NP | NP | Permitted in public right-of-way with an encroachment permit. Pursuant to ABC requirements as well as the city’s outdoor dining permit and guidelines. |
19. Outdoor Display and Sales | NP | NP | NP | NP | NP | May not encroach into public right-of-way. |
20. Pet Store, Pet Boarding, Animal Shelter | UP | UP | UP | NP | NP | Sheltering and boarding shall require a use permit. |
21. Restaurant | P | P | P | NP | NP | |
22. Restaurant with Alcohol Sales | UP | UP | UP | NP | NP | |
23. Secondhand/Thrift/ Consignment/Pawn/Charity Store | UP | UP | UP | NP | NP | |
24. Service Station | NP | NP | NP | NP | NP | |
25. Tobacco Sales, including Electronic Smoking Devices | UP | UP | UP | NP | NP | |
Services – Business, Financial, Medical, Professional | ||||||
1. ATM | P | P | P | NP | NP | Must be integrated into building façade. Stand alone kiosks not permitted. |
2. Bank (2,000 sf or less) | P | P | P | NP | NP | Banks over 2,000 sf are not permitted. |
3. Business Support Services (copying, printing, office supplies, etc.) | P | P | P | NP | NP | |
4. Hospital | NP | NP | NP | NP | NP | |
5. Medical Office | P | P | P | NP | NP | See definition. Only permitted on upper floors, except in R-2 overlay. |
6. Office | P | P | P | NP | P | See definition. Only permitted on upper floors except in R-2 overlay. |
Services – General | ||||||
1. Adult Daycare | NP | NP | NP | NP | NP | |
2. Cigar or Hookah Lounge | UP | UP | UP | NP | NP | |
3. Commercial Daycare Center | UP | UP | UP | NP | NP | |
4. Hostess Bars | NP | NP | NP | NP | NP | |
5. Laundromat and Laundry Services | UP | UP | UP | NP | NP | |
6. Lodging – B&B | UP | UP | NP | NP | NP | |
7. Lodging – Hotel | UP | UP | UP | NP | NP | |
8. Massage Establishments | UP | UP | UP | NP | NP | Not permitted on the ground floor in any subarea. Pursuant to PMC § 23.30.030 |
9. Meeting Halls, Banquet Centers (Stand alone) | NP | NP | NP | NP | NP | |
10. Personal Services | P | P | P | NP | NP | |
11. Public Safety Facility | NP | NP | NP | NP | P | |
12. Spa Services (with or without alcohol) | UP | UP | UP | NP | NP | |
13. Tattoo Parlors/Body Modification | UP | UP | UP | NP | NP | |
Transportation, Communications & Infrastructure | ||||||
1. Broadcasting or Recording Studio | UP | UP | UP | NP | NP | May only be permitted on upper floors of mixed-use development. |
2. Public Parking Structure or Surface Parking Lot | UP | UP | UP | UP | P | |
3. Transit Station or Terminal | NP | NP | NP | NP | NP | |
4. Telecommunication Cell Tower/Microcell and Small Cell Sites | Pursuant to PMC Ch. 23.82 | |||||
Notes: | |
|---|---|
(1) | See Section 25.112.050, Development standards, for frontage requirements regarding building located at 102 S. Bradford Ave. |
(2) | Within the R-2 overlay zone, no retail or commercial uses are permitted on the ground floor. |
Table 2. Development Standards | ||||||
|---|---|---|---|---|---|---|
Development Standard | Planning Subareas | Notes and Additional Requirements | ||||
Main Street | Village | Mixed-Use | High-Density Residential | Public Facility | ||
Residential Density | ||||||
1. Density (max du/ac) | 25 | 35 | 55 | 65 | NA | Density shall be calculated using gross lot size, prior to any required right-of-way dedications. |
Setbacks. Minimum setbacks required and, where noted, maximum setbacks established, except where a frontage type standard allows exceptions or establishes different requirements. Setbacks are measured from property line after any required dedications. Fire department requirements supersede any setback listed below. | ||||||
1. Setback from Railroad Track | NA | NA | NA | 0 ft. | 0 ft. | 10′ from rear ROW preferred by BNSF for above ground structures. Applicants should consider access to rear portion of new development. |
2. Front Yard Setback (min-max) | 0 ft. | 0-5 ft. | 5-15 ft. | 5-15 ft. | NA | All setback areas facing a street or alley not devoted to walkways and driveways shall be properly landscaped and maintained in compliance with PMC Ch. 23.77. In the R-2 overlay zone, the front yard setback shall be 15′. |
3. Front Yard Setback for “through lots” and cross-alley developments in the R-2 overlay, fronting Alta and Main. See definitions section. | 15 ft. | 15 ft. | 15 ft. | NA | NA | |
4. Side Yard Setback | 0 ft. | 0 ft. | 0 ft. | 0 ft. | NA | |
5. Side Yard Setback for “through lots” and cross-alley developments in the R-2 overlay, fronting Alta and Main. See definitions section. | 0-5 ft.* | 0-5 ft.* | NA | 0 ft. | NA | *Less than 5′ setback adjoining an R-2 use requires approval from adjoining property owner of said R-2 use. |
6. Rear Yard Setback (min-max) | 0-15 ft. | 0-15 ft. | 0-15 ft. | 0 ft. | NA | |
7. Street Side Yard Setback (minmax) | 0 ft. | 0-5 ft. | 5* ft. | 5-15 ft. | NA | *Refers to Chapman Avenue setback. |
Projections and Encroachments | ||||||
1. Allowable Setback Projections | a. Ground Floor: i. Awnings and canopies over windows: 60″; ii. Barriers for defining outdoor dining areas such as fences, railings, planter boxes: as needed to encompass outdoor dining area; iii. Sun shade structures: 15′; iv. Bay windows: 60″ (not wider than 10′); v. Cornices, belt courses, and similar architectural features: 12″; vi. Eaves, roof overhangs: 30″; and vii. Uncovered porches, decks and landings (may be covered by arbors or trellises): 10′. b. Above Ground Floor. Awnings, galleries, balconies, bay windows: 48″ c. Art, as determined by the approval of the public art component of the project. d. For signs, see sign regulations, § 23.112.070. e. All projections must maintain a minimum of 8′ vertical clearance from ground. | |||||
2. Public Right-of-Way Encroachments (all require approval of an encroachment permit) | a. Art, as determined by the approval of the public art component of the project. b. For signs, see sign regulations, § 23.111.070. c. Outdoor dining is allowed by approval of the director of development services and director of public works or their designees and may require Alcoholic Beverage Control Board (ABC) approval. Approval is pursuant to the outdoor dining permit and guidelines. | |||||
Heights, Rooftop Amenities, Frontages, Lot Sizes | ||||||
1. Building Height | 2-Story Area: 2 stories, 30′ 3-Story Area: 3 stories, 40′ 4-Story Area: 4 stories, 55′ | 2 min/3 max stories, 40′ | 3 min/4 max stories, 60′ | 3 min/4 max stories, 55′ | 5 stories, 65′ | See “Old Town zoning map” for height subareas. New stories built on top of existing buildings shall be fully integrated into the design of the existing building. |
2. Minimum Lot Size required for a development at or over 3 stories. | 0 | 8,000 sf* | 10,000 sf | 10,000 sf | 0 | *Developments on lots smaller than 8,000 sf can be considered if they are contiguous to parcels with proposed or approved new developments and are developed with a zero lot line scenario or similar concept. The development on the smaller lot must complement and enhance the contiguous development and further the goals of this chapter. |
3. Ground Floor Height measured from finished floor to ceiling (min) | 15 ft. | 15 ft. | 15 ft. | NA | NA | |
4. Frontage Requirements | In order to support the pedestrian environment, building frontages onto streets and open spaces shall be maximized. No visible parking is permitted along frontages. A minimum of 75% of the site frontage shall be occupied as building frontage. A section of blank wall shall not exceed 20 linear feet without being interrupted by a window or entry or other façade treatment. | |||||
5. Rooftop Amenities | In multifamily residential and mixed-use residential projects, rooftop amenities, such as and not limited to, clubhouses, swimming pools, tennis courts, open space areas, fitness centers, are permitted to project 16′ above the maximum height limit if integrated into the overall design of the project and the maximum rooftop building coverage is limited to 30% of the rooftop floor area. Rooftop amenities shall be set back from the building edge such that no more than 20% of the rooftop structure can be visible from the primary public right-of-way at centerline of the street. Rooftop amenities are intended for the use of building residents. Rooftop amenities do not count as a “story” or “floor.” | |||||
6. Height Exceptions | Non-habitable building features such as chimneys (up to 6′ in width), cupolas, flagpoles, monuments, steeples, roof screens, equipment, and similar structures, covering no more than 10% of the top floor roof area to which they are accessory, may exceed maximum permitted height standards by up to 8′. | |||||
7. Building Orientation | New commercial or mixed use construction must orient the principal façade onto Bradford, Santa Fe or Chapman Avenue or Walnut Avenue. In the mixed use subarea, new buildings must be oriented toward Bradford and Chapman. | NA | NA | |||
8. Building Façade for building located at 102 S. Bradford Avenue (at Chapman) | The building façade of this building shall be preserved and integrated into the new design of any new development proposed on this site. This includes the façade along Bradford Ave (including the tower and the front section containing the large round window opening) and up to and including the façade (containing the stained glass windows) along Chapman Avenue. The Chapman Avenue façade preservation can end at the point where the planes of the two sections of that façade meet (where the east/west oriented portion of the building meets the north/south oriented portion of the building). The preservation does not necessarily have to include the small vestibule. The proposed architectural design of any new development shall be reviewed by a preservation architect; the selection of such preservation expert shall be approved by the city. | |||||
Provision of Common Open Space (Residential Only) | ||||||
1. Amount per Residential Use | a. 50 sf/unit for residential units; b. 50 sf/unit for 5 or more live work units. | |||||
2. Types of Common Open Space Permitted | a. Common open space can be active or passive but must be accessible to all nonresidential tenants (i.e., employees and employers) and residential residents. b. Required setbacks may not be counted as common open space. c. Common open space shall be fully landscaped and requires an approved landscape plan. d. Examples may include: courtyards, clubhouses with accompanying landscaped areas, swimming pools, plazas, greens, parks, playgrounds, picnic areas, outdoor seating. | |||||
3. Rooftop Amenities | 1. Rooftop amenities are permitted if they provide additional recreational or common open space activities. 2. Amenities, such as and not limited to, clubhouses, swimming pools, tennis courts, open space areas, fitness centers, are permitted to project 16′ above the maximum height limit if integrated into the overall design of the project and the maximum rooftop building coverage is limited to 30% of the rooftop floor area. Roof top amenities shall be set back from the building edge such that no more than 20% of the rooftop structure can be visible from the primary public right-of-way at centerline of the street. Rooftop amenities are intended for the use of building residents. 3. 50% of the rooftop amenities (structures and active recreation amenities) may count towards the square footage requirement for either private or common open space. 4. Rooftop buildings supporting recreational activities may cover a maximum of 30% of the rooftop area and may project above the maximum height limit by 16′. | |||||
4. Courtyard and Common Open Space Requirements | 1. Courtyards shall be designed as a central courtyard or as partial, multiple, separated or interconnected courtyards. 2. Minimum courtyard dimension shall be 40′ when the long axis of the courtyard is oriented EW and 30′ for a NS orientation. The courtyard proportion is 1:1 between its width and height for at least 2/3 of the court’s perimeter. As long as total open space requirement is met, this ratio could be modified by up to 10%. 3. When there are 2 or more courtyards, they shall be connected to each other. | |||||
Provision of Private Open Space (Residential and Live/Work Only) | ||||||
Amount per Residential Unit | 64 sf/unit | 6′ min. in any direction; the total of 64 sf must be provided as one private open space area, not broken up into smaller sizes. | ||||
Shopfronts | ||||||
The following are specific guidelines for shopfronts in the Old Town area: 1. 12′ to 16′ tall, as measured from the adjacent sidewalk. 2. The corresponding storefront(s) opening(s) along the primary frontage shall comprise 65% of the 1st floor wall area facing the street and not have opaque, stucco or reflective glazing. 3. Storefronts may be recessed from the frontage line by up to 10′. 4. “Bulkheads,” which are a segment of wall that transitions between the window opening(s) and the adjacent grade, are also encouraged. The bulkhead shall be between 24″ and 36″ tall (aluminum storefront or spandrel panel may not substitute for a bulkhead). | ||||||
Architectural Styles | ||||||
1. Main Street Commercial Multi-story façades are typically divided into base, body and top with the ground floor taller than the shorter upper floor which is finished by a significant parapet. The ground floor has recessed entries and any expansive glass is interrupted by structural columns with transoms to allow light to penetrate deep into the interior. Upper floor windows are smaller with vertical windows directly relating to the ground floor openings. | Style of architecture required in Main Street subareas | |||||
2. Mission Revival Prominent features of the style include red clay tile roofs, use of balconies, smooth-stuccoed exterior walls usually painted white, arched openings, colorful tile work and elaborate landscaping. The buildings frequently have courtyards. | Choices of architecture for the following: • Village subarea • Mixed use subarea • High density residential subarea | |||||
3. Spanish Colonial Typical features include a low-pitched roof with little or no eave overhang, a red-tiled roof, perhaps a prominent rounded arch over a door, window or porch, a stucco wall surface, and usually an asymmetrical façade. The features elaborate molded ornament around doors and windows, polychrome tile at ingresses and wrought iron grilles and balconies. | This style of architecture permitted only in high density residential subarea | |||||
Table 3. Parking Standards | ||
|---|---|---|
Parking Standards | Standards | Applicable Land Uses |
Nonresidential | ||
Retail – spaces per 1,000 sf | 2 min./4 max. | Accessory retail, antique, artisan, bank, business support services, general retail, grocery, retail complex, personal services, pet store/boarding. |
Eating and Drinking Establishments – spaces per 1,000 sf | 5 min./10 max | Bar/tavern, restaurant, brewery, etc. |
Outdoor Dining | 0 | Provided the outdoor dining area does not exceed the interior dining area. Any square footage over the interior dining area shall provide parking pursuant to the eating and drinking establishment requirement above. |
Specialty Goods & Foods – spaces per 1,000 sf | 2 min./4 max. | |
Entertainment & Recreation – spaces per 1,000 sf | 6 min./10 max. | Health/fitness, recreation, playgrounds, studios, theatres cannot be stand alone. |
Commercial Goods – spaces per 1,000 sf | 2 min./4 max. | |
Civic & Cultural, including libraries, museums – spaces per 1,000 sf | 3 min./no max. | |
Office Professional – spaces per 1,000 sf | 2 min./4 max. | |
Personal Services | 3 min./no max. | |
Live Work | 1 min./1.5 max. | |
ATM | 0 | |
Lodging – Bed & Breakfast | 1 per sleeping room. | No assembly space permitted. |
Lodging – Hotel | 1 per sleeping room, plus 1 space for every 75 sf of assembly area. | |
Residential | ||
Spaces per studio unit | 1 min./1 max. | |
Spaces per 1 bed unit | 1 min./1.5 max. | |
Spaces per 2 bed unit | 1.5 min./2 max. | |
Spaces per 3 or more bed unit | 2 min./2.5 max. | |
Guest spaces per 10 units | 2 min./3 max. | |
Mixed-Use | ||
Mixed Use | Parking shall meet the requirements for individual land uses. Residential parking shall be separated from nonresidential parking and easily accessible through a controlled mechanism. | Reduced parking may be permitted through a parking study. |
Other | ||
Transit Station or Terminal | As per director of development services in coordination with transportation authority. | |
Telecommunication Facility, Small/Micro Cell Sites | 1 space to service facility. | |
Table 4. Sign Standards by Use | |||
|---|---|---|---|
Multifamily Residential Use | |||
Allowed Sign | Maximum Sign Height | Maximum No. of Signs Allowed per Parcel | Maximum Sign Area Allowed per Parcel |
1. Wall or Freestanding | Wall signs: below edge of roof. Placement shall only be located below the roof or over the primary entrance. Freestanding: 48 in. | 1 wall sign or freestanding sign per entrance or street frontage | 12 sf each per face area; 24 sf maximum total sf for all signs. |
1. Awning | Shall be entirely on awning valance; lettering max 66% of valance height; valance height max: 18 in. | 50% of the area of the valance front. 1 sign max per each separate awning valance. | 1. Awning |
2. Marquee | To be established during project review. Allowed only for the entrance of a theatre or playhouse. | To be established during project review. 1 sign max | 2. Marquee |
Nonresidential Use/Mixed-Use | ||
|---|---|---|
Allowed Sign | Placement Standards | Maximum Number and Sign Area |
3. Monument | 5 ft. including base structure. Allowed only on a site with more than 100 ft. of continuous street frontage. | 36 sf |
4. Projecting or Suspended | 16 inches from face of building and bottom of sign shall be no closer than 8 ft. above sidewalk surface below. | 6 sf. No dimension greater than 3 ft. Sign shall be redwood sandblasted, hand carved or architecturally designed. |
5. Wall | 2 ft. below parapet or eave. Individual letters 18 inches. | 1 sf. per linear foot primary business. |
Mounting 1-story: above 1st floor windows. | 1 sign allowed per business frontage with pedestrian entrance. | |
Mounting multi-story: between windows. | Side street or rear entrance wall sign max 50% of the primary sign area. | |
6. Window Permanent | Within window area | 15% of total window area max. |
7. Window Temporary | Within window area | 25% of total window area. Allowed for display a maximum of 15 days at 1 time, up to 3 times in a 12-month period. |
8. A-Boards and other Portable Sidewalk Signs are permitted | May not impede pedestrian flow. | 1 per business. Signs may only be permitted while the business is open. Requires an encroachment permit if in the public right-of-way and a creative sign permit. |
9. Building Wall Facing RR ROW | Businesses may have signage equal to or less than the allowable projecting or wall sign standards. | Building or parcel must front along Crowther Avenue and the Railroad ROW. |
10. Directional Signage on Private Property | Cannot be freestanding and shall be minimized for basic directional functions. | Included in sign permit application approval process. |