LIGHTING PLAN SUBMITTAL REQUIREMENTS
The lighting plan shall be drawn to a scale no larger than one inch: 50 feet and shall contain the following information:
1.
The type of lamp to be used in each fixture, including the manufacturer's name and part number, lamp wattage, lumen output, and a copy of the manufacturer's lamp specifications;
2.
Fixture heights measured from grade and locations of the same;
3.
The type of fixtures, including the manufacturer's name and model number; wattage; a picture of the fixture; and the IES file name;
4.
Point-to-point photometric calculations at intervals of not more than ten feet at ground level demonstrating that the plan will provide a uniform intensity of lighting on vehicular surfaces;
5.
The area of each photometric calculation, including an extra calculation to identify the light level produced at the property line, and all data used in each calculation; and
6.
The seal of the qualified Alabama registered design professional.
LIGHTING PLAN SUBMITTAL REQUIREMENTS
The lighting plan shall be drawn to a scale no larger than one inch: 50 feet and shall contain the following information:
1.
The type of lamp to be used in each fixture, including the manufacturer's name and part number, lamp wattage, lumen output, and a copy of the manufacturer's lamp specifications;
2.
Fixture heights measured from grade and locations of the same;
3.
The type of fixtures, including the manufacturer's name and model number; wattage; a picture of the fixture; and the IES file name;
4.
Point-to-point photometric calculations at intervals of not more than ten feet at ground level demonstrating that the plan will provide a uniform intensity of lighting on vehicular surfaces;
5.
The area of each photometric calculation, including an extra calculation to identify the light level produced at the property line, and all data used in each calculation; and
6.
The seal of the qualified Alabama registered design professional.