124 Downtown Zones
The downtown zoning categories implement the downtown specific plan titled “Fast Forward Spokane” along with the goals and policies and land use plan map designations of the comprehensive plan. The differences in the zoning categories reflect the desired character for different downtown areas. The zones are distinguished by the design, intensity, and form of development allowed. A wide range of uses is allowed in each zone. The zones encourage a wide mix of residential, recreational, commercial, office, and some light industrial uses. The intensity of the uses allowed and the development and design standards promote the desired character within the zone. The development standards are designed to allow a large degree of development flexibility within parameters that support the intent of the specific zone. The standards are intended to provide certainty to property owners, developers, and neighbors about the limits of what is allowed in the various zoning categories.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
All projects must address the pertinent design standards and guidelines. A determination of consistency with the standards and guidelines will be made by the planning and economic development services director following an administrative design review process. Design standards are in the form of Requirements (R), Presumptions (P), and Considerations (C). Regardless of which term is used, an applicant must address each guideline. An applicant may seek to deviate from eligible standards and guidelines through the design departure process; see chapter 17G.030 SMC, Design Departures.
Requirements are mandatory in that they contain language that is not discretionary, such as “shall,” “must,” and “will.” Requirements must be satisfied by any plan prior to building permit approval. An applicant may seek a deviation from certain requirements through the design departure process, chapter 17G.030 SMC. Requirements are listed with an (R) after the standard.
Presumptions are guidelines that are meant to be applied, but with some flexibility. Presumptions indicate that the City is open to design features that are equal to, or better than, that stated – so long as the purpose is satisfied. A submitted plan is incomplete and will be rejected if it does not demonstrate that the presumptive elements have been in some way incorporated or overcome. Presumptions are listed with a (P) after the standard.
A presumption that may be unsuitable for a given project may be waived if an applicant can demonstrate to the planning and economic development services director that there is a good reason why the presumption is inappropriate. The director may approve an alternative that achieves the intent of the presumption. At the discretion of the applicant, or in rare cases the director may refer the permit to the design review committee. A referral from the director would be in those cases where the complexity of the project and/or the cumulative impacts of deviations result in the project no longer meeting the overall intent of the design standards and the comprehensive plan.
Note: Increases in the cost of development will not be an acceptable reason to waive a guideline or determine that a guideline is inappropriate.
Design guidelines listed as considerations are features and concepts that an applicant should consider in preparing a plan. Their omission is not grounds for rejecting a plan, but their inclusion or recognition is encouraged and may assist in overcoming certain presumptions and in gaining acceptance for a plan. Considerations are listed with a (C) after the standard.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
The full and short names of the downtown zones and their zoning map symbols are listed below. When this chapter and other chapters within the Unified Development Code (Title 17 SMC) refer to the downtown zones, they are referring to the zoning categories listed here.
Full Name | Short Name / Zoning Map Symbol |
Downtown Core | DTC |
Downtown General | DTG |
Downtown University | DTU |
Downtown South | DTS |
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
The downtown zones are complemented by the complete streets designations map (described in detail in the downtown plan) that further guides public and private development within the downtown. The different complete streets designations set different street standards and desired amenities based upon the intended use and desired qualities of the street. The complete streets designations are depicted on Map 5.1 “Streetscape Improvements” in the downtown plan and zoning layer. Right-of-ways found on the complete streets map shall not be vacated as the space is needed to incorporate the elements described in the complete street designation; provided, upon a finding that a vacation is needed in order to accommodate a public use, the City Council may approve a request to vacate such right-of-ways or portions thereof. Curb to property line and the sidewalk width shall not be reduced in order to allow for future complete street elements. The complete streets designation types are summarized below:
A. Type I – Community Activity Street.
Type I streets are slow, two-way streets with wide, well-maintained sidewalks and pedestrian amenities to encourage strolling, walking, and shopping.
B. Type II – Community Connector.
Type II streets move traffic and pedestrians into and around downtown. There streets provide some of the major pedestrian connection to surrounding neighborhoods and districts.
C. Type III – City-Regional Connector.
Type III streets move auto traffic through downtown and provide connections to the rest of the City and region. These attractive, landscaped arterials are to be improved with street trees, sufficient sidewalks for pedestrian circulation and pedestrian buffer areas, and safe pedestrian crossings.
D. Type IV – Neighborhood Streets.
Type IV streets carry little through traffic and tend to have less commercial activity than the other types of complete streets. These tend to have generous sidewalks, landscaping, and street trees. All downtown streets will meet Type IV criteria to a minimum.
E. Alleys.
Alleys provide the best opportunity to prioritize the pedestrian above the motor vehicle. Alleys are critical service areas where deliveries and refuse collection shall be focused. Alley encroachments shall be removable and allow for nightly access.”
Date Passed: Monday, November 4, 2019
Effective Date: Monday, November 4, 2019
ORD C35826 Section 2
The standards in this chapter state the allowed uses and the development standards for the base downtown zones. Sites with overlay zones, plan districts, or designated historical landmarks are subject to additional standards. The official zoning maps indicate which sites are subject to the additional standards. Specific uses or development types may also be subject to standards in Part 3, Special Use Standards, of this division.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
Table 17C.124.100-1 Downtown Zone Primary Uses (See Linked Document)
Date Passed: Monday, June 23, 2014
Effective Date: Friday, August 8, 2014
ORD C35098 Section 5
This regulation applies to all parts of Table 17C.124.100-1 that have a [1].
All group living uses except for alternative or post-incarceration facilities are allowed by right.
Group living uses which consist of alternative or post incarceration facilities are conditional uses.
This regulation applies to all parts of Table 17C.124.100-1 that have a [2]. Adult businesses are subject to the additional standards of chapter 17C.305 SMC.
This regulation applies to all parts of Table 17C.124.100-1 that have a [3]. See SMC 17C.230.310 for the parking structure design guidelines. See SMC 17C.124.340, Parking and Loading, for ground level parking structure use standards.
This regulation applies to all parts of Table 17C.124.100-1 that have a [4]. Drive-through facilities are subject to the additional standards of SMC 17C.124.290.
This regulation applies to all parts of Table 17C.124.100-1 that have a [5]. Quick vehicle servicing uses are permitted only on sites that have frontage on a Type III or IV complete street. Quick vehicle servicing uses must be fully contained within a structure. Quick vehicle servicing uses are subject to the additional standards of SMC 17C.124.290.
This regulation applies to all parts of Table 17C.124.100-1 that have a [6]. Sale, rental, or leasing of motor vehicles, including passenger vehicles, light and medium trucks is not allowed. Sale, rental, and leasing of motorcycles and other recreational vehicles not able to be licensed for normal on street use is allowed. For sale or leasing of motorcycles and other recreational vehicles see SMC 17C.124.270, Outdoor Activities.
This regulation applies to all parts of Table 17C.124.100-1 that have a [7]. These types of uses are limited to assure that they will not dominate the downtown area and to limit their potential impacts on residential and commercial uses. In addition, if the planning and economic development services director determines that the proposed use will not be able to comply with the off-site impact standards of chapter 17C.220 SMC, the planning and economic development services director may require documentation that the development will be modified to conform with the standards.
This regulation applies to all parts of Table 17C.124.100-1 that have an [8]. See SMC 17C.124.340.
This regulation applies to all parts of Table 17C.124.100-1 that have an [9]. Mini-storage facilities are subject to the additional standards of chapter 17C.350 SMC, Mini-storage Facilities.
This regulation applies to all parts of Table 17C.124.100-1 that have a [10]. Outdoor display, storage, or use of industrial equipment or other industrial items such as tools, equipment, vehicles, products, materials, or other objects that are part of or used for the business operation is prohibited.
This regulation applies to all parts of Table 17C.124.100-1 that have a [11]. Most community service uses are allowed by right.
See chapter 17C.355A SMC.
This regulation applies to all parts of Table 17C.124.100-1 that have an [13]. Light industrial and self-service storage uses in operation on the effective date of this ordinance, are considered to be a conforming use.
This standard applies to all parts of Table 17C.124.100-1 that have a [14]. All mobile food vendors shall have a valid mobile food vending license issued pursuant to SMC 10.51.010.
Date Passed: Monday, March 29, 2021
Effective Date: Thursday, May 6, 2021
ORD C36024 Section 2
Uses that are accessory to a primary use are allowed if they comply with specific standards for the accessory uses and all development standards. See chapter 17C.190 SMC, Use Category Descriptions.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
Dimensional standards for new development within the downtown are found in Table 17C.124.210-1, Development Standards. Creation of new lots is subject to the standards of chapter 17G.080 SMC, Subdivisions.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
FAR Standard.
The floor area ratios are stated in Table 17C.124.210-1. To determine the allowed gross floor area of all structures allowed on a site, the FAR in the Table 17C.124.210-1 below is multiplied by the area of the lot. The following are excluded from FAR calculations:
Floor area dedicated to parking.
Elevators, staircases, escalators, and mechanical spaces.
Exterior decks, porches, and arcades open to the air.

Table 17C.124.210-1 Development Standards [1] | ||||
Standard | DTC | DTG | DTU | DTS |
Maximum FAR [2] | No Limit | 6 | 6 | 4 |
Maximum height [3] | No Limit | 12 Stories [3] | 12 Stories [3] | 12 Stories [3] |
Minimum setback from street lot line [4,5] | 0 ft. | 0 ft. | 0 ft. | 0 ft. |
Minimum setback from R-zoned lots [5] | 10 ft. | 10 ft. | 10 ft. | 10 ft. |
Minimum setback from lot lines [5] | 0 ft. | 0 ft. | 0 ft. | 0 ft. |
Minimum front lot line | 10 ft | 10 ft. | 10 ft. | 10 ft. |
Landscaping required [6] | [6] | [6] | [6] | [6] |
Parking required [7] | [7] | [7] | [7] | [7] |
Notes: | ||||
Date Passed: Monday, January 11, 2016
Effective Date: Wednesday, February 24, 2016
ORD C35346 Section 7
The height and massing standards control the overall scale of buildings. These standards downtown allow for building height and mass at a scale that generally reflects the most intensive area within the City. The standards help to preserve light, air, and the potential for privacy in lower intensity residential zones that are adjacent to the downtown zones.
The height and massing standards for all structures are stated in Table 17C.124-2 and as shown on the zoning map. Bonus height may be allowed as defined in SMC 17C.124.220(E). The Bonus height provisions are not available within downtown zones that have a maximum height specified on the zoning map by a dash and a maximum height specified after the zone map symbol (i.e. DTG-100).
Changes to the height limits are not allowed outside of a downtown plan update process.
Chimneys, flag poles, satellite receiving dishes, and other similar items with a width, depth, or diameter of five feet or less may rise ten feet above the height limit, or five feet above the highest point of the roof, whichever is greater. If they are greater than five feet in width, depth, or diameter, they are subject to the height limit.
All rooftop mechanical equipment must be set back at least fifteen feet from all roof edges visible from streets. Elevator mechanical equipment may extend up to sixteen feet above the height limit. Other rooftop mechanical equipment which cumulatively covers no more than ten percent of the roof area may extend ten feet above the height limit.
The height limits do not apply to uninhabitable space under four hundred square feet in floor area that is devoted to decorative architectural features such belfries, spires, and clock towers.
The first story of the building may be up to twenty-five feet tall and still count as only one story.
Special height districts are established to control structure heights under particular circumstances such as preservation of public view or airport approaches and protection. See chapter 17C.170 SMC, Special Height Overlay Districts.
For the properties shown in Figure 17C.124.220-1 that are located in the area generally west of Monroe Street, east of Cedar Street, and between Main Avenue and Riverside Avenue, the maximum height shall be as shown in Figures 17C.124.220-1 and 17C.124.220-2.
Figure 17C.124.220-1
Notes for Figure 17C.124.220-1.
Figure 17C.124.220-2
Additional stories for structures where the maximum height is specified with a dash after the zoning map symbol (i.e. DTG-70).
These standards are designed to transition the building bulk and mass for buildings exceeding seven stories in the DTG, DTU, and DTS zones.
All stories above the seventh story shall be setback from all property lines and street lot lines a minimum of fifteen feet.
The provision of an exterior public space as defined below allows for encroachment into the upper story stepback. The allowed area of encroachment may not exceed an area equal to five times the area of the exterior public space.
Exterior Public Space(s) – A Plaza or Courtyard With a Minimum Area of Two Hundred Square Feet.
A plaza or a courtyard is a level space accessible to the public, at least ten feet in width, with a building façade on at least one side. The elevation of the courtyard or plaza shall be within thirty inches of the grade of the sidewalk providing access to it. For courtyards, at least sixty percent of the green shall be planted with trees, ground cover and other vegetation. For plazas, at least fifteen percent, but no more than sixty percent of the space shall be planted with trees, ground cover and other vegetation. Courtyards and plazas shall also include seating, pedestrian-scale lighting, decorative paving, and other pedestrian furnishings. The use of artists to create fixtures and furnishings is strongly encouraged.
The bonus height provisions are not available within specially designated height areas or the downtown zones that have a maximum height specified on the zoning map by a dash and a maximum height specified after the zone map symbol (i.e. DTG-100).
Additional bonus stories may be achieved if a development incorporates specified and described public amenities allowing bonus height and stories above the number of stories allowed outright in the zone. The bonus stories are in addition to what is specified in Table 17C.124-2. The number of stories above the number of stories allowed outright may be increased through a ministerial process intended to ensure that each amenity both satisfies design criteria and serves a public purpose in the proposed location. Amenities provided must be associated with the use for which the height increase is sought. Proposed amenities shall have a public benefit that is appropriate considering the height increase being achieved.
These standards are designed to transition the apparent building height and mass for buildings that exceed twelfth stories in the DTG, DTU, and DTS zones. All stories above the twelfth story must meet the following standards. The following floor area and maximum diagonal plan tower dimension shall be measured from the inside face of the outside wall.
Preferred uses include retail sales and service or entertainment use, or any combination thereof, located on the ground floor with direct access and fronting on a street.
Structure envelop devoted to permanent affordable household living space (housing units affordable to households making less than eighty percent of area median income for the City as defined by HUD) is not subject to a height or story limit.
An area equal to the area devoted to permanent affordable housing that lies below the twelfth story may be added above the twelfth story in residential use that is not affordable housing.
Subject to the requirements of chapter 17D.070 SMC, Transfer of Development Rights, additional building height and gross floor area may be transferred from a building on the Spokane register of historic places that is within a downtown zone to a new development within a downtown zone. The TDR may be transferred from a historic landmark located on the same site or from a historic landmark located on a separate site.
The following items each qualify for two bonus stories.
One ground floor use that “spills” (single use) per one hundred foot of structure street frontage.
Preferred uses include retail sales and service or entertainment use, or any combination thereof, located on the ground floor with direct access and fronting on a street.
A virtually continuous canopy structure. A canopy is a permanent architectural element projecting out from a building facade over a sidewalk or walkway. A canopy shall be at least five feet in horizontal width and be no less than eight feet and no more than twelve feet above grade.
Decorative paving, pedestrian-scaled lighting, special paving, and rear entrances intended to encourage pedestrian use of the alley.
Seating, trees, pedestrian-scaled lighting, and special paving in addition to any that are required by the design standards and guidelines.
A small scale minor water feature integrated within an open space or plaza between the structure and public sidewalk. Small scale minor water features are generally designed to be viewed but not physically interacted with.
Including historic plaques or markings about the local area or site. Reusing historic building elements and features on the site. Reusing existing landmark signs.
Providing covered bicycle parking for all required bicycle parking along with other bicycle amenities such as secured bicycle lockers and equipment storage facilities.
The following items qualify for four bonus stories each.
An additional ten feet of upper floor stepback from the street lot lines.
Use of brick and stone on the building facades that face streets on the first three stories of the building.
One ground floor use that “spills” per thirty feet of structure street frontage. Preferred uses include retail sales and service or entertainment use, or any combination thereof, located on the ground floor with direct access and fronting on a street.
A plaza or courtyard, with a minimum area of four hundred square feet or one percent of the site size, whichever is greater. A plaza or a courtyard is a level space accessible to the public, at least ten feet in width, with a building façade on at least one side. The elevation of the courtyard or plaza shall be within thirty inches of the grade of the sidewalk providing access to it. For courtyards, at least sixty percent of the green shall be planted with trees, ground cover and other vegetation. For plazas, at least fifteen percent, but no more than sixty percent of the space shall be planted with trees, ground cover and other vegetation. Courtyards and plazas shall also include seating, pedestrian-scale lighting, decorative paving and other pedestrian furnishings. The use of artists to create fixtures and furnishings is strongly encouraged.
For this bonus, the housing units shall be affordable to households earning one hundred twenty percent or less of area medium income (AMI). For homes to be purchased the total housing payment (principal, interest, taxes, and insurance, PITI) shall be no more than thirty-three percent of income. For rental housing the rent plus utilities shall be no more than thirty percent of income.
Public art includes sculptures, murals, inlays, mosaics, and other two-dimensional or three-dimensional works, as well as elements integrated into the design of a project (e.g., fountain) that are designed and crafted by one or more artists. Such artists must be listed on a registry of either the Washington state arts commission or the Spokane arts commission. To receive the bonus, public art must be documented at a value that is at least one percent of the construction value of the bonus stories.
Through-block pedestrian connection providing a continuous walkway accessible to the public, at least ten feet in width, paved with decorative paving and lighted for nighttime use. It may be covered or open to the sky.
A major water feature integrated within an open space or plaza between the structure and public sidewalk. A major water feature is designed to be viewed and is large enough to be physically interacted with by the public. It shall be at least ten square feet in size as measure in plan view.
A planted area of a roof covering greater than fifty percent of the roof surface.
The following items qualify for eight bonus stories each.
For this bonus, the housing units shall be affordable to households earning one hundred twenty percent or less of area medium income (AMI). For homes to be purchased the total housing payment (principal, interest, taxes, and insurance, PITI) shall be no more than thirty-three percent of income. For rental housing the rent plus utilities shall be no more than thirty percent of income.
Structures containing two hundred thousand square feet or more of office gross floor area shall include shower facilities and clothing storage areas for bicycle commuters. One shower per gender shall be required. Such facilities shall be for the use of the employees and occupants of the building, and shall be located where they are easily accessible to parking facilities for bicycles.
Date Passed: Monday, November 2, 2015
Effective Date: Monday, November 2, 2015
ORD C35312 Section 9
The required structure setbacks promote streetscapes that are consistent with the desired character of the different downtown zones and the character of the complete street designation of the adjacent street. The sidewalk standards provide a continuous, safe, and consistent street frontage character along the street right-of-way.
The setback standards for all structures are stated in Table 17C.124.210-1, Development Standards, and as stated below.
Exception to Maintain Existing Historic Character:
Exceptions:
TABLE 17C.124.230-1 Building Setbacks & Complete Streets [1] | |||
DTC | DTG | DTU | DTS |
All Streets | Type I, II | Type I, II, IV | Type I, II, IV |
Notes: | |||
Street trees must be installed and maintained by the adjacent property in all streets bordering development. Requirements for street trees and landscaping are stated in chapter 17C.200 SMC, Landscaping and Screening.
The setback standards for detached accessory structures are stated in SMC 17C.124.300. Fences are addressed in SMC 17C.124.310. Sign standards are in chapter 17C.240 SMC, Signs.
The following features attached to structures are allowed as exceptions to the setback standards except they shall not reduce the required sidewalk width of subsection (B) of this section.
In addition to subsection (F)(1)(b) of this section, the following features are allowed to project farther into required structure setbacks:
Attached mechanical structures such as heat pumps, air conditioners, emergency generators, and water pumps are not allowed between the street lot line and buildings or within any required setback from an abutting residential zone.
Date Passed: Monday, February 25, 2013
Effective Date: Thursday, April 4, 2013
ORD C34961 Section 5
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
The standards of this section are intended to assure that outdoor sales, display, storage, and work activities:
Outdoor activities associated with permitted uses shall be permitted subject to the standards of the zone and as described below.
Where permitted, the following outdoor activities shall be located at least fifty feet from a residential zone or an existing residentially use:
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
Site Access Standards.
When a lot abuts an alley, alley access shall be required, unless the director otherwise determines under (C).
Adjacent developments should share new or existing driveways and curb cuts to the greatest extent possible.
When a site does not abut an alley and abuts more than one right-of-way, the new curb cut location shall be based upon the following complete street hierarchy. The curb cuts shall be focused onto lower priority complete streets.
Vehicular access should first be from alleys, then from Type IV, Type III, Type II streets.
Type I complete streets shall only allow curb cuts when there are no other alternatives for access to the site.
Curb Cut Spacing.
Curb cuts shall be located at least forty feet away from street intersections.
On an individual site a maximum of two curb cuts for one-way traffic at least forty feet apart, or one curb cut for two-way traffic, is permitted on each street front where access is permitted.

Curb Cut Width.
The maximum curb cut width for one-way traffic shall be fifteen feet. Driveway width for one way traffic where the sidewalk crosses the driveway shall not exceed twelve feet in width.

Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
Drive-through facilities are allowed in the zones that are intended for auto-accommodating development. They are limited in areas where the desired character is pedestrian-oriented development. Additional standards for drive-through facilities are stated in chapter 17C.325 SMC, Drive-through Facilities.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
These standards are to ensure that the required sidewalk width is maintained and that there is a transition between the downtown zones and abutting residential zones.
Covered structures such as storage buildings, garages, greenhouses, work shed, covered decks, and covered recreational structures are subject to the setbacks for structures.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
The fence standards promote the positive benefits of fences without negatively impacting the community or endangering public or vehicle safety. Fences near streets are kept low in order to allow visibility into and out of the site and to ensure visibility for motorists.
The standards apply to walls, fences, and screens of all types whether open, solid, wood, metal, wire, masonry, or other material.
Colors shall complement the primary color of the development and shall not be so extreme in contrast or intensity that the color competes with the building for attention. Proposed fencing materials and colors that differ from these standards are subject to an administrative design review process.
Sight-obscuring fences, walls, and other structures over three and one-half feet high and visible from a street are subject to SMC 17C.124.570, Treating Blank Walls – Building Design.
Date Passed: Monday, January 11, 2016
Effective Date: Wednesday, February 24, 2016
ORD C35346 Section 8
Existing development that does not conform to the development standards of this chapter is subject to the standards of chapter 17C.210 SMC, Nonconforming Situations.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
The standards pertaining to the minimum required and maximum allowed number of auto parking spaces, minimum required number of bicycle parking spaces, parking lot placement, parking lot setbacks, and internal parking lot pedestrian connections are stated in chapter 17C.230 SMC, Parking and Loading.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
The sign standards are stated in chapter 17C.240 SMC, Sign Code.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
Purpose.
In the downtown the facade and window standards are required in order to:
provide a pleasant, rich, and diverse pedestrian-friendly experience by connecting activities occurring within a structure to adjacent sidewalk areas;
encourage observation or viewing opportunities by restricting fortress-like facades at street level; and
Required Street Facing Window Area and Façade Features.
These provisions apply to building facades in the downtown zones.
For buildings facades visible from, fronting on, and located within sixty feet of a lot line of a complete street the minimum percentage window glazing requirements found within Table 17C.124.510-1 Complete Street Window Standards apply. On the ground floor, display windows may be used to meet half of the requirement. (R)
On Type III streets in the DTG, DTU, and DTS zones a minimum of fifty percent of any ground floor nonresidential building facade that is visible from and located within twenty feet of the lot line of an arterial street designated on the arterial street plan shall be comprised of windows. Display windows may be used to meet half of this requirement. (R)
In all downtown zones, buildings that do not front on a designated complete street or an alley a minimum of thirty percent of any ground floor nonresidential building facade that is visible from, fronting on, and located within sixty feet of the lot line of the street shall be comprised of windows. Display windows may be used to meet half of this requirement. (R)
In all cases, required window glazing between two and forty feet shall comprise of clear, “vision” glass allowing views into the interior. (R)
Blank wall areas on street facing facades may not extend more than twenty-five feet without a window, glass-covered display area, entryway, or a recessed area of a minimum size of two feet deep by six feet wide by ten feet high.
Maximum ground floor blank wall length
Table 17C.124.510-1 Complete Street Window Standards [1] | ||||
| DTC | DTG | DTU | DTS |
Window Requirement of Facades of Non-residential Uses Fronting a Complete Street by Street Type | All Streets | Type I, II, IV | Type I, II, IV | Type I, II, IV |
Ground Floor Facades between 2 and 10 feet | 60% | 60% | 60% | 60% |
Between 10 and 40 feet | 40% | 40% | 40% | 40% |
| ||||
Window Requirement of Facades of Residential Uses Fronting a Complete Street by Street Type [2] | All Streets | Type I, II, IV | Type I, II, IV | Type I, II, IV |
Facades between 2 and 40 feet | 20% | 20% | 20% | 20% |
Notes: [1] Plan district or overlay zone standards may supersede these standards. [2] Ground floor residential uses should be raised a minimum of two feet from average sidewalk grade.
| ||||

Facade surface for non-residential

Facade surface for residential uses
Visual connection between indoor and outdoor spaces




Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
Base/Middle/Top Implementation.
Buildings shall have a distinct “base” at the ground level, using articulation and materials such as stone, masonry, or decorative concrete. (P)


A distinctive cornice with parapet define the top

The changes in amount and form of
windows along with details such as
belt lines help to define the base,
middle, and top.

Different materials can be used at the ground level
to define a "base."
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
Articulation Implementation.
Facades longer than fifty feet shall be broken down into smaller units through the use of offsets, recesses, staggered walls, stepped walls, pitched or stepped rooflines, overhangs and other elements of the building’s mass. Simply changing materials or color is not sufficient to accomplish this. (R)


A change in the materials used along
the façade along with window shades
and belt course, reduces the perceived
mass of large buildings.

A recessed entry, balconies, canopies, a change in
materials, and window patterns all add to articulation
of the façade.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
Prominent Entrance Implementation.
Principal entry to the store/building shall be marked by at least one element from Group A and one element from Group B: (R)
Group A.
Large entry doors.
Recessed entrance.
Protruding entrance.
Group B.
Canopy.
Portico.

Weather protection provided by a canopy and large
entry doors help to define this entrance.

A recessed entry with overhead weather protections
and distinctive and artistic doors define the entrance.

This entrance is emphasized by a multistory protrusion that
breaks up the massing, along with an emphasized cornice,
and overhead weather protection over the entry doors.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
Ground Level Details Implementation.
Ground level of building shall be pedestrian-friendly in scale, expression and use of materials. (R)
Ground floor of the buildings shall have at least three of the following elements: (P)
Large windows.
Kickplates for storefront window.
Projecting sills.
Pedestrian scale signs.
Canopies.
Large ground floor windows, kick plates, and recessed entries reinforce the character of the ground level.



Ground level details can be subtle, like the planter boxes,
pedestrian level signage and window detailing.

Each building in this row uses different ground level
windows and facade details.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
To ensure that rooflines present a distinct profile and appearance for the building.
Buildings with flat roofs shall have portions with pitched roofs, extended parapets or projecting cornices to create a prominent edge when viewed against the sky, especially to highlight major entrances. (P)


Portion of roof extended.

Traditional extended parapet and cornice with emphasis
over entrance.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
To mitigate blank walls by providing visual interest.
Where windows are not provided on walls (or portions of walls) facing streets or visible from right-of-way, at least four of the following elements shall be incorporated: (R)



Historic elements used on section of
blank wall.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
To provide a pedestrian-friendly environment by creating a variety of usable and interesting open spaces within private development.


Plaza with seating located at main entrance

Landscaping and enhances plaza/courtyard area
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
To maintain a view corridor for pedestrians at the street level from the intersection of Riverside Avenue and Jefferson Street to the Spokane County Courthouse.
A clear view shall be maintained at the pedestrian and street level between the intersection of Riverside Avenue and Jefferson Street and the Spokane County Courthouse.

View looking north from Jefferson Street toward
Spokane County Courthouse.

Courthouse View Corridor
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
To ensure that upper floors with blank facades on tall buildings are visually interesting when viewed from surrounding streets and buildings.

Artistic mural

Textured surface

Articulation/recessed windows

Trompe l'oeil (painted facade)
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
124 Downtown Zones
The downtown zoning categories implement the downtown specific plan titled “Fast Forward Spokane” along with the goals and policies and land use plan map designations of the comprehensive plan. The differences in the zoning categories reflect the desired character for different downtown areas. The zones are distinguished by the design, intensity, and form of development allowed. A wide range of uses is allowed in each zone. The zones encourage a wide mix of residential, recreational, commercial, office, and some light industrial uses. The intensity of the uses allowed and the development and design standards promote the desired character within the zone. The development standards are designed to allow a large degree of development flexibility within parameters that support the intent of the specific zone. The standards are intended to provide certainty to property owners, developers, and neighbors about the limits of what is allowed in the various zoning categories.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
All projects must address the pertinent design standards and guidelines. A determination of consistency with the standards and guidelines will be made by the planning and economic development services director following an administrative design review process. Design standards are in the form of Requirements (R), Presumptions (P), and Considerations (C). Regardless of which term is used, an applicant must address each guideline. An applicant may seek to deviate from eligible standards and guidelines through the design departure process; see chapter 17G.030 SMC, Design Departures.
Requirements are mandatory in that they contain language that is not discretionary, such as “shall,” “must,” and “will.” Requirements must be satisfied by any plan prior to building permit approval. An applicant may seek a deviation from certain requirements through the design departure process, chapter 17G.030 SMC. Requirements are listed with an (R) after the standard.
Presumptions are guidelines that are meant to be applied, but with some flexibility. Presumptions indicate that the City is open to design features that are equal to, or better than, that stated – so long as the purpose is satisfied. A submitted plan is incomplete and will be rejected if it does not demonstrate that the presumptive elements have been in some way incorporated or overcome. Presumptions are listed with a (P) after the standard.
A presumption that may be unsuitable for a given project may be waived if an applicant can demonstrate to the planning and economic development services director that there is a good reason why the presumption is inappropriate. The director may approve an alternative that achieves the intent of the presumption. At the discretion of the applicant, or in rare cases the director may refer the permit to the design review committee. A referral from the director would be in those cases where the complexity of the project and/or the cumulative impacts of deviations result in the project no longer meeting the overall intent of the design standards and the comprehensive plan.
Note: Increases in the cost of development will not be an acceptable reason to waive a guideline or determine that a guideline is inappropriate.
Design guidelines listed as considerations are features and concepts that an applicant should consider in preparing a plan. Their omission is not grounds for rejecting a plan, but their inclusion or recognition is encouraged and may assist in overcoming certain presumptions and in gaining acceptance for a plan. Considerations are listed with a (C) after the standard.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
The full and short names of the downtown zones and their zoning map symbols are listed below. When this chapter and other chapters within the Unified Development Code (Title 17 SMC) refer to the downtown zones, they are referring to the zoning categories listed here.
Full Name | Short Name / Zoning Map Symbol |
Downtown Core | DTC |
Downtown General | DTG |
Downtown University | DTU |
Downtown South | DTS |
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
The downtown zones are complemented by the complete streets designations map (described in detail in the downtown plan) that further guides public and private development within the downtown. The different complete streets designations set different street standards and desired amenities based upon the intended use and desired qualities of the street. The complete streets designations are depicted on Map 5.1 “Streetscape Improvements” in the downtown plan and zoning layer. Right-of-ways found on the complete streets map shall not be vacated as the space is needed to incorporate the elements described in the complete street designation; provided, upon a finding that a vacation is needed in order to accommodate a public use, the City Council may approve a request to vacate such right-of-ways or portions thereof. Curb to property line and the sidewalk width shall not be reduced in order to allow for future complete street elements. The complete streets designation types are summarized below:
A. Type I – Community Activity Street.
Type I streets are slow, two-way streets with wide, well-maintained sidewalks and pedestrian amenities to encourage strolling, walking, and shopping.
B. Type II – Community Connector.
Type II streets move traffic and pedestrians into and around downtown. There streets provide some of the major pedestrian connection to surrounding neighborhoods and districts.
C. Type III – City-Regional Connector.
Type III streets move auto traffic through downtown and provide connections to the rest of the City and region. These attractive, landscaped arterials are to be improved with street trees, sufficient sidewalks for pedestrian circulation and pedestrian buffer areas, and safe pedestrian crossings.
D. Type IV – Neighborhood Streets.
Type IV streets carry little through traffic and tend to have less commercial activity than the other types of complete streets. These tend to have generous sidewalks, landscaping, and street trees. All downtown streets will meet Type IV criteria to a minimum.
E. Alleys.
Alleys provide the best opportunity to prioritize the pedestrian above the motor vehicle. Alleys are critical service areas where deliveries and refuse collection shall be focused. Alley encroachments shall be removable and allow for nightly access.”
Date Passed: Monday, November 4, 2019
Effective Date: Monday, November 4, 2019
ORD C35826 Section 2
The standards in this chapter state the allowed uses and the development standards for the base downtown zones. Sites with overlay zones, plan districts, or designated historical landmarks are subject to additional standards. The official zoning maps indicate which sites are subject to the additional standards. Specific uses or development types may also be subject to standards in Part 3, Special Use Standards, of this division.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
Table 17C.124.100-1 Downtown Zone Primary Uses (See Linked Document)
Date Passed: Monday, June 23, 2014
Effective Date: Friday, August 8, 2014
ORD C35098 Section 5
This regulation applies to all parts of Table 17C.124.100-1 that have a [1].
All group living uses except for alternative or post-incarceration facilities are allowed by right.
Group living uses which consist of alternative or post incarceration facilities are conditional uses.
This regulation applies to all parts of Table 17C.124.100-1 that have a [2]. Adult businesses are subject to the additional standards of chapter 17C.305 SMC.
This regulation applies to all parts of Table 17C.124.100-1 that have a [3]. See SMC 17C.230.310 for the parking structure design guidelines. See SMC 17C.124.340, Parking and Loading, for ground level parking structure use standards.
This regulation applies to all parts of Table 17C.124.100-1 that have a [4]. Drive-through facilities are subject to the additional standards of SMC 17C.124.290.
This regulation applies to all parts of Table 17C.124.100-1 that have a [5]. Quick vehicle servicing uses are permitted only on sites that have frontage on a Type III or IV complete street. Quick vehicle servicing uses must be fully contained within a structure. Quick vehicle servicing uses are subject to the additional standards of SMC 17C.124.290.
This regulation applies to all parts of Table 17C.124.100-1 that have a [6]. Sale, rental, or leasing of motor vehicles, including passenger vehicles, light and medium trucks is not allowed. Sale, rental, and leasing of motorcycles and other recreational vehicles not able to be licensed for normal on street use is allowed. For sale or leasing of motorcycles and other recreational vehicles see SMC 17C.124.270, Outdoor Activities.
This regulation applies to all parts of Table 17C.124.100-1 that have a [7]. These types of uses are limited to assure that they will not dominate the downtown area and to limit their potential impacts on residential and commercial uses. In addition, if the planning and economic development services director determines that the proposed use will not be able to comply with the off-site impact standards of chapter 17C.220 SMC, the planning and economic development services director may require documentation that the development will be modified to conform with the standards.
This regulation applies to all parts of Table 17C.124.100-1 that have an [8]. See SMC 17C.124.340.
This regulation applies to all parts of Table 17C.124.100-1 that have an [9]. Mini-storage facilities are subject to the additional standards of chapter 17C.350 SMC, Mini-storage Facilities.
This regulation applies to all parts of Table 17C.124.100-1 that have a [10]. Outdoor display, storage, or use of industrial equipment or other industrial items such as tools, equipment, vehicles, products, materials, or other objects that are part of or used for the business operation is prohibited.
This regulation applies to all parts of Table 17C.124.100-1 that have a [11]. Most community service uses are allowed by right.
See chapter 17C.355A SMC.
This regulation applies to all parts of Table 17C.124.100-1 that have an [13]. Light industrial and self-service storage uses in operation on the effective date of this ordinance, are considered to be a conforming use.
This standard applies to all parts of Table 17C.124.100-1 that have a [14]. All mobile food vendors shall have a valid mobile food vending license issued pursuant to SMC 10.51.010.
Date Passed: Monday, March 29, 2021
Effective Date: Thursday, May 6, 2021
ORD C36024 Section 2
Uses that are accessory to a primary use are allowed if they comply with specific standards for the accessory uses and all development standards. See chapter 17C.190 SMC, Use Category Descriptions.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
Dimensional standards for new development within the downtown are found in Table 17C.124.210-1, Development Standards. Creation of new lots is subject to the standards of chapter 17G.080 SMC, Subdivisions.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
FAR Standard.
The floor area ratios are stated in Table 17C.124.210-1. To determine the allowed gross floor area of all structures allowed on a site, the FAR in the Table 17C.124.210-1 below is multiplied by the area of the lot. The following are excluded from FAR calculations:
Floor area dedicated to parking.
Elevators, staircases, escalators, and mechanical spaces.
Exterior decks, porches, and arcades open to the air.

Table 17C.124.210-1 Development Standards [1] | ||||
Standard | DTC | DTG | DTU | DTS |
Maximum FAR [2] | No Limit | 6 | 6 | 4 |
Maximum height [3] | No Limit | 12 Stories [3] | 12 Stories [3] | 12 Stories [3] |
Minimum setback from street lot line [4,5] | 0 ft. | 0 ft. | 0 ft. | 0 ft. |
Minimum setback from R-zoned lots [5] | 10 ft. | 10 ft. | 10 ft. | 10 ft. |
Minimum setback from lot lines [5] | 0 ft. | 0 ft. | 0 ft. | 0 ft. |
Minimum front lot line | 10 ft | 10 ft. | 10 ft. | 10 ft. |
Landscaping required [6] | [6] | [6] | [6] | [6] |
Parking required [7] | [7] | [7] | [7] | [7] |
Notes: | ||||
Date Passed: Monday, January 11, 2016
Effective Date: Wednesday, February 24, 2016
ORD C35346 Section 7
The height and massing standards control the overall scale of buildings. These standards downtown allow for building height and mass at a scale that generally reflects the most intensive area within the City. The standards help to preserve light, air, and the potential for privacy in lower intensity residential zones that are adjacent to the downtown zones.
The height and massing standards for all structures are stated in Table 17C.124-2 and as shown on the zoning map. Bonus height may be allowed as defined in SMC 17C.124.220(E). The Bonus height provisions are not available within downtown zones that have a maximum height specified on the zoning map by a dash and a maximum height specified after the zone map symbol (i.e. DTG-100).
Changes to the height limits are not allowed outside of a downtown plan update process.
Chimneys, flag poles, satellite receiving dishes, and other similar items with a width, depth, or diameter of five feet or less may rise ten feet above the height limit, or five feet above the highest point of the roof, whichever is greater. If they are greater than five feet in width, depth, or diameter, they are subject to the height limit.
All rooftop mechanical equipment must be set back at least fifteen feet from all roof edges visible from streets. Elevator mechanical equipment may extend up to sixteen feet above the height limit. Other rooftop mechanical equipment which cumulatively covers no more than ten percent of the roof area may extend ten feet above the height limit.
The height limits do not apply to uninhabitable space under four hundred square feet in floor area that is devoted to decorative architectural features such belfries, spires, and clock towers.
The first story of the building may be up to twenty-five feet tall and still count as only one story.
Special height districts are established to control structure heights under particular circumstances such as preservation of public view or airport approaches and protection. See chapter 17C.170 SMC, Special Height Overlay Districts.
For the properties shown in Figure 17C.124.220-1 that are located in the area generally west of Monroe Street, east of Cedar Street, and between Main Avenue and Riverside Avenue, the maximum height shall be as shown in Figures 17C.124.220-1 and 17C.124.220-2.
Figure 17C.124.220-1
Notes for Figure 17C.124.220-1.
Figure 17C.124.220-2
Additional stories for structures where the maximum height is specified with a dash after the zoning map symbol (i.e. DTG-70).
These standards are designed to transition the building bulk and mass for buildings exceeding seven stories in the DTG, DTU, and DTS zones.
All stories above the seventh story shall be setback from all property lines and street lot lines a minimum of fifteen feet.
The provision of an exterior public space as defined below allows for encroachment into the upper story stepback. The allowed area of encroachment may not exceed an area equal to five times the area of the exterior public space.
Exterior Public Space(s) – A Plaza or Courtyard With a Minimum Area of Two Hundred Square Feet.
A plaza or a courtyard is a level space accessible to the public, at least ten feet in width, with a building façade on at least one side. The elevation of the courtyard or plaza shall be within thirty inches of the grade of the sidewalk providing access to it. For courtyards, at least sixty percent of the green shall be planted with trees, ground cover and other vegetation. For plazas, at least fifteen percent, but no more than sixty percent of the space shall be planted with trees, ground cover and other vegetation. Courtyards and plazas shall also include seating, pedestrian-scale lighting, decorative paving, and other pedestrian furnishings. The use of artists to create fixtures and furnishings is strongly encouraged.
The bonus height provisions are not available within specially designated height areas or the downtown zones that have a maximum height specified on the zoning map by a dash and a maximum height specified after the zone map symbol (i.e. DTG-100).
Additional bonus stories may be achieved if a development incorporates specified and described public amenities allowing bonus height and stories above the number of stories allowed outright in the zone. The bonus stories are in addition to what is specified in Table 17C.124-2. The number of stories above the number of stories allowed outright may be increased through a ministerial process intended to ensure that each amenity both satisfies design criteria and serves a public purpose in the proposed location. Amenities provided must be associated with the use for which the height increase is sought. Proposed amenities shall have a public benefit that is appropriate considering the height increase being achieved.
These standards are designed to transition the apparent building height and mass for buildings that exceed twelfth stories in the DTG, DTU, and DTS zones. All stories above the twelfth story must meet the following standards. The following floor area and maximum diagonal plan tower dimension shall be measured from the inside face of the outside wall.
Preferred uses include retail sales and service or entertainment use, or any combination thereof, located on the ground floor with direct access and fronting on a street.
Structure envelop devoted to permanent affordable household living space (housing units affordable to households making less than eighty percent of area median income for the City as defined by HUD) is not subject to a height or story limit.
An area equal to the area devoted to permanent affordable housing that lies below the twelfth story may be added above the twelfth story in residential use that is not affordable housing.
Subject to the requirements of chapter 17D.070 SMC, Transfer of Development Rights, additional building height and gross floor area may be transferred from a building on the Spokane register of historic places that is within a downtown zone to a new development within a downtown zone. The TDR may be transferred from a historic landmark located on the same site or from a historic landmark located on a separate site.
The following items each qualify for two bonus stories.
One ground floor use that “spills” (single use) per one hundred foot of structure street frontage.
Preferred uses include retail sales and service or entertainment use, or any combination thereof, located on the ground floor with direct access and fronting on a street.
A virtually continuous canopy structure. A canopy is a permanent architectural element projecting out from a building facade over a sidewalk or walkway. A canopy shall be at least five feet in horizontal width and be no less than eight feet and no more than twelve feet above grade.
Decorative paving, pedestrian-scaled lighting, special paving, and rear entrances intended to encourage pedestrian use of the alley.
Seating, trees, pedestrian-scaled lighting, and special paving in addition to any that are required by the design standards and guidelines.
A small scale minor water feature integrated within an open space or plaza between the structure and public sidewalk. Small scale minor water features are generally designed to be viewed but not physically interacted with.
Including historic plaques or markings about the local area or site. Reusing historic building elements and features on the site. Reusing existing landmark signs.
Providing covered bicycle parking for all required bicycle parking along with other bicycle amenities such as secured bicycle lockers and equipment storage facilities.
The following items qualify for four bonus stories each.
An additional ten feet of upper floor stepback from the street lot lines.
Use of brick and stone on the building facades that face streets on the first three stories of the building.
One ground floor use that “spills” per thirty feet of structure street frontage. Preferred uses include retail sales and service or entertainment use, or any combination thereof, located on the ground floor with direct access and fronting on a street.
A plaza or courtyard, with a minimum area of four hundred square feet or one percent of the site size, whichever is greater. A plaza or a courtyard is a level space accessible to the public, at least ten feet in width, with a building façade on at least one side. The elevation of the courtyard or plaza shall be within thirty inches of the grade of the sidewalk providing access to it. For courtyards, at least sixty percent of the green shall be planted with trees, ground cover and other vegetation. For plazas, at least fifteen percent, but no more than sixty percent of the space shall be planted with trees, ground cover and other vegetation. Courtyards and plazas shall also include seating, pedestrian-scale lighting, decorative paving and other pedestrian furnishings. The use of artists to create fixtures and furnishings is strongly encouraged.
For this bonus, the housing units shall be affordable to households earning one hundred twenty percent or less of area medium income (AMI). For homes to be purchased the total housing payment (principal, interest, taxes, and insurance, PITI) shall be no more than thirty-three percent of income. For rental housing the rent plus utilities shall be no more than thirty percent of income.
Public art includes sculptures, murals, inlays, mosaics, and other two-dimensional or three-dimensional works, as well as elements integrated into the design of a project (e.g., fountain) that are designed and crafted by one or more artists. Such artists must be listed on a registry of either the Washington state arts commission or the Spokane arts commission. To receive the bonus, public art must be documented at a value that is at least one percent of the construction value of the bonus stories.
Through-block pedestrian connection providing a continuous walkway accessible to the public, at least ten feet in width, paved with decorative paving and lighted for nighttime use. It may be covered or open to the sky.
A major water feature integrated within an open space or plaza between the structure and public sidewalk. A major water feature is designed to be viewed and is large enough to be physically interacted with by the public. It shall be at least ten square feet in size as measure in plan view.
A planted area of a roof covering greater than fifty percent of the roof surface.
The following items qualify for eight bonus stories each.
For this bonus, the housing units shall be affordable to households earning one hundred twenty percent or less of area medium income (AMI). For homes to be purchased the total housing payment (principal, interest, taxes, and insurance, PITI) shall be no more than thirty-three percent of income. For rental housing the rent plus utilities shall be no more than thirty percent of income.
Structures containing two hundred thousand square feet or more of office gross floor area shall include shower facilities and clothing storage areas for bicycle commuters. One shower per gender shall be required. Such facilities shall be for the use of the employees and occupants of the building, and shall be located where they are easily accessible to parking facilities for bicycles.
Date Passed: Monday, November 2, 2015
Effective Date: Monday, November 2, 2015
ORD C35312 Section 9
The required structure setbacks promote streetscapes that are consistent with the desired character of the different downtown zones and the character of the complete street designation of the adjacent street. The sidewalk standards provide a continuous, safe, and consistent street frontage character along the street right-of-way.
The setback standards for all structures are stated in Table 17C.124.210-1, Development Standards, and as stated below.
Exception to Maintain Existing Historic Character:
Exceptions:
TABLE 17C.124.230-1 Building Setbacks & Complete Streets [1] | |||
DTC | DTG | DTU | DTS |
All Streets | Type I, II | Type I, II, IV | Type I, II, IV |
Notes: | |||
Street trees must be installed and maintained by the adjacent property in all streets bordering development. Requirements for street trees and landscaping are stated in chapter 17C.200 SMC, Landscaping and Screening.
The setback standards for detached accessory structures are stated in SMC 17C.124.300. Fences are addressed in SMC 17C.124.310. Sign standards are in chapter 17C.240 SMC, Signs.
The following features attached to structures are allowed as exceptions to the setback standards except they shall not reduce the required sidewalk width of subsection (B) of this section.
In addition to subsection (F)(1)(b) of this section, the following features are allowed to project farther into required structure setbacks:
Attached mechanical structures such as heat pumps, air conditioners, emergency generators, and water pumps are not allowed between the street lot line and buildings or within any required setback from an abutting residential zone.
Date Passed: Monday, February 25, 2013
Effective Date: Thursday, April 4, 2013
ORD C34961 Section 5
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
The standards of this section are intended to assure that outdoor sales, display, storage, and work activities:
Outdoor activities associated with permitted uses shall be permitted subject to the standards of the zone and as described below.
Where permitted, the following outdoor activities shall be located at least fifty feet from a residential zone or an existing residentially use:
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
Site Access Standards.
When a lot abuts an alley, alley access shall be required, unless the director otherwise determines under (C).
Adjacent developments should share new or existing driveways and curb cuts to the greatest extent possible.
When a site does not abut an alley and abuts more than one right-of-way, the new curb cut location shall be based upon the following complete street hierarchy. The curb cuts shall be focused onto lower priority complete streets.
Vehicular access should first be from alleys, then from Type IV, Type III, Type II streets.
Type I complete streets shall only allow curb cuts when there are no other alternatives for access to the site.
Curb Cut Spacing.
Curb cuts shall be located at least forty feet away from street intersections.
On an individual site a maximum of two curb cuts for one-way traffic at least forty feet apart, or one curb cut for two-way traffic, is permitted on each street front where access is permitted.

Curb Cut Width.
The maximum curb cut width for one-way traffic shall be fifteen feet. Driveway width for one way traffic where the sidewalk crosses the driveway shall not exceed twelve feet in width.

Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
Drive-through facilities are allowed in the zones that are intended for auto-accommodating development. They are limited in areas where the desired character is pedestrian-oriented development. Additional standards for drive-through facilities are stated in chapter 17C.325 SMC, Drive-through Facilities.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
These standards are to ensure that the required sidewalk width is maintained and that there is a transition between the downtown zones and abutting residential zones.
Covered structures such as storage buildings, garages, greenhouses, work shed, covered decks, and covered recreational structures are subject to the setbacks for structures.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
The fence standards promote the positive benefits of fences without negatively impacting the community or endangering public or vehicle safety. Fences near streets are kept low in order to allow visibility into and out of the site and to ensure visibility for motorists.
The standards apply to walls, fences, and screens of all types whether open, solid, wood, metal, wire, masonry, or other material.
Colors shall complement the primary color of the development and shall not be so extreme in contrast or intensity that the color competes with the building for attention. Proposed fencing materials and colors that differ from these standards are subject to an administrative design review process.
Sight-obscuring fences, walls, and other structures over three and one-half feet high and visible from a street are subject to SMC 17C.124.570, Treating Blank Walls – Building Design.
Date Passed: Monday, January 11, 2016
Effective Date: Wednesday, February 24, 2016
ORD C35346 Section 8
Existing development that does not conform to the development standards of this chapter is subject to the standards of chapter 17C.210 SMC, Nonconforming Situations.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
The standards pertaining to the minimum required and maximum allowed number of auto parking spaces, minimum required number of bicycle parking spaces, parking lot placement, parking lot setbacks, and internal parking lot pedestrian connections are stated in chapter 17C.230 SMC, Parking and Loading.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
The sign standards are stated in chapter 17C.240 SMC, Sign Code.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
Purpose.
In the downtown the facade and window standards are required in order to:
provide a pleasant, rich, and diverse pedestrian-friendly experience by connecting activities occurring within a structure to adjacent sidewalk areas;
encourage observation or viewing opportunities by restricting fortress-like facades at street level; and
Required Street Facing Window Area and Façade Features.
These provisions apply to building facades in the downtown zones.
For buildings facades visible from, fronting on, and located within sixty feet of a lot line of a complete street the minimum percentage window glazing requirements found within Table 17C.124.510-1 Complete Street Window Standards apply. On the ground floor, display windows may be used to meet half of the requirement. (R)
On Type III streets in the DTG, DTU, and DTS zones a minimum of fifty percent of any ground floor nonresidential building facade that is visible from and located within twenty feet of the lot line of an arterial street designated on the arterial street plan shall be comprised of windows. Display windows may be used to meet half of this requirement. (R)
In all downtown zones, buildings that do not front on a designated complete street or an alley a minimum of thirty percent of any ground floor nonresidential building facade that is visible from, fronting on, and located within sixty feet of the lot line of the street shall be comprised of windows. Display windows may be used to meet half of this requirement. (R)
In all cases, required window glazing between two and forty feet shall comprise of clear, “vision” glass allowing views into the interior. (R)
Blank wall areas on street facing facades may not extend more than twenty-five feet without a window, glass-covered display area, entryway, or a recessed area of a minimum size of two feet deep by six feet wide by ten feet high.
Maximum ground floor blank wall length
Table 17C.124.510-1 Complete Street Window Standards [1] | ||||
| DTC | DTG | DTU | DTS |
Window Requirement of Facades of Non-residential Uses Fronting a Complete Street by Street Type | All Streets | Type I, II, IV | Type I, II, IV | Type I, II, IV |
Ground Floor Facades between 2 and 10 feet | 60% | 60% | 60% | 60% |
Between 10 and 40 feet | 40% | 40% | 40% | 40% |
| ||||
Window Requirement of Facades of Residential Uses Fronting a Complete Street by Street Type [2] | All Streets | Type I, II, IV | Type I, II, IV | Type I, II, IV |
Facades between 2 and 40 feet | 20% | 20% | 20% | 20% |
Notes: [1] Plan district or overlay zone standards may supersede these standards. [2] Ground floor residential uses should be raised a minimum of two feet from average sidewalk grade.
| ||||

Facade surface for non-residential

Facade surface for residential uses
Visual connection between indoor and outdoor spaces




Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
Base/Middle/Top Implementation.
Buildings shall have a distinct “base” at the ground level, using articulation and materials such as stone, masonry, or decorative concrete. (P)


A distinctive cornice with parapet define the top

The changes in amount and form of
windows along with details such as
belt lines help to define the base,
middle, and top.

Different materials can be used at the ground level
to define a "base."
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
Articulation Implementation.
Facades longer than fifty feet shall be broken down into smaller units through the use of offsets, recesses, staggered walls, stepped walls, pitched or stepped rooflines, overhangs and other elements of the building’s mass. Simply changing materials or color is not sufficient to accomplish this. (R)


A change in the materials used along
the façade along with window shades
and belt course, reduces the perceived
mass of large buildings.

A recessed entry, balconies, canopies, a change in
materials, and window patterns all add to articulation
of the façade.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
Prominent Entrance Implementation.
Principal entry to the store/building shall be marked by at least one element from Group A and one element from Group B: (R)
Group A.
Large entry doors.
Recessed entrance.
Protruding entrance.
Group B.
Canopy.
Portico.

Weather protection provided by a canopy and large
entry doors help to define this entrance.

A recessed entry with overhead weather protections
and distinctive and artistic doors define the entrance.

This entrance is emphasized by a multistory protrusion that
breaks up the massing, along with an emphasized cornice,
and overhead weather protection over the entry doors.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
Ground Level Details Implementation.
Ground level of building shall be pedestrian-friendly in scale, expression and use of materials. (R)
Ground floor of the buildings shall have at least three of the following elements: (P)
Large windows.
Kickplates for storefront window.
Projecting sills.
Pedestrian scale signs.
Canopies.
Large ground floor windows, kick plates, and recessed entries reinforce the character of the ground level.



Ground level details can be subtle, like the planter boxes,
pedestrian level signage and window detailing.

Each building in this row uses different ground level
windows and facade details.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
To ensure that rooflines present a distinct profile and appearance for the building.
Buildings with flat roofs shall have portions with pitched roofs, extended parapets or projecting cornices to create a prominent edge when viewed against the sky, especially to highlight major entrances. (P)


Portion of roof extended.

Traditional extended parapet and cornice with emphasis
over entrance.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
To mitigate blank walls by providing visual interest.
Where windows are not provided on walls (or portions of walls) facing streets or visible from right-of-way, at least four of the following elements shall be incorporated: (R)



Historic elements used on section of
blank wall.
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
To provide a pedestrian-friendly environment by creating a variety of usable and interesting open spaces within private development.


Plaza with seating located at main entrance

Landscaping and enhances plaza/courtyard area
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
To maintain a view corridor for pedestrians at the street level from the intersection of Riverside Avenue and Jefferson Street to the Spokane County Courthouse.
A clear view shall be maintained at the pedestrian and street level between the intersection of Riverside Avenue and Jefferson Street and the Spokane County Courthouse.

View looking north from Jefferson Street toward
Spokane County Courthouse.

Courthouse View Corridor
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1
To ensure that upper floors with blank facades on tall buildings are visually interesting when viewed from surrounding streets and buildings.

Artistic mural

Textured surface

Articulation/recessed windows

Trompe l'oeil (painted facade)
Date Passed: Monday, December 14, 2009
Effective Date: Saturday, January 16, 2010
Ordinance C34522 Section 1