Zoneomics Logo
search icon

Starkville City Zoning Code

SECTION 9

Special Districts

The intent of the Special Use District is to implement the Special District placetype of the Starkville Comprehensive Plan as it relates to community institutions such as medical institutions, schools, municipal facilities, and parks, and other uses related to civic, recreation, or social activities. The Special District provides for a range of spatial forms based upon the use and intensity intended.

9.1.1 General Provisions

  1. The intent is for concentrations of medical facilities and related uses to be in a “campus” setting that will better accommodate the needs of the medical profession and those served by it. Facilities on and immediately surrounding Hospital Road will be subject to these provisions.
  2. Uses include: assisted living facilities, care centers, community associations, civic associations, nursing homes, educational facilities, group care homes, hospitals, life care communities, municipal buildings, municipal facilities, parks, places of worship, public buildings, public facilities, medical offices, professional offices, retail sales, and research facilities. The City Planner shall determine if a proposed use is appropriate.

9.1.2 Base Dimensional Standards

Special Use Medical

 

A. Lot Dimensions

S-M

A1. Lot size (min)

*

A2. Lot width (min)

*

B. Building/Structure Setbacks

S-M

B1. Front setback min

25’

B2. Side setback

10’

B3. Side setback adjacent to detached residential

20’**

B4. Side setback corner lot

15’

B5. Rear setback

20’

B6. Rear setback adjacent to detached residential

20’**

D. Parking Setbacks

S-M

D1. From primary and adjacent streets

5’

D2. From side and rear property line

5’

D3. From adjacent residential

20’

E. Height

S-M

E1. Principal building(s) (max)

30’, 2 story

E2. Accessory structure(s) (max)

15’, 1 story

F. Pedestrian Access

S-M

F1. Street-facing primary entrance along street

yes

*lots must be of a sufficient size to accommodate the proposed use and meet all subsequent development standards

** see additional development standards for proposed use

9.2.1 General Provisions

  1. Any City of Starkville owned, managed, and/or partially-owned building used for purposes such as, but not limited to: administrative functions, emergency services, utilities, public facilities, and/or parks and recreation.
  2. Municipal Building: Any City of Starkville owned, managed, and/or partial owned building.
  3. Municipal Structures or Facilities: Any City of Starkville owned, managed, and/or partial owned structure or other facility used for infrastructure-related municipal uses such as but not limited to: sewer lift stations, electric utility substations, water towers, and water pump facilities.
  4. Parks and Recreation: Any City of Starkville owned, managed, and/or partial owned space used for passive or active recreation.

9.2.2 Base Dimensional Standards

Special Use Institutional

A. Lot Dimensions

S-I

A1 Lot size (min)

*

A2 Lot width (min)

*

B. Building/Structure Setbacks

S-I

B1 Front setback min

30’ or infill standards

B2 Side setback

10’

B3 Side setback adjacent to detached residential

20’**

B4 Side setback corner lot

30’ or infill standards

B5 Rear setback

10’

B6 Rear setback adjacent to detached residential

20**

D. Parking Setbacks

S-I

D1 From primary and adjacent streets

5’**

D2 From adjacent residential

20’**

E. Height

S-I

E1 Principal building(s) (max)

**

E2 Accessory structure(s) (max)

**

*lots must be of a sufficient size to accommodate the proposed use and meet all subsequent development standards

** see additional development standards for proposed use

9.3.1 General Provisions

  1. PK-12: Any public or private institution providing educational services to grades PK-12.
  2. Higher-education: Any public or private institution providing higher education, specialized professional, or vocational training.

9.3.2 Base Dimensional Standards

Special Use Educational

A. Lot Dimensions

S-E

A1 Lot size (min)

*

A2 Lot width (min)

*

B. Building/Structure Setbacks

S-E

B1 Front setback min

25’ or infill standards

B2 Side setback

10’

B3 Side setback adjacent to detached residential

50’

B4 Side setback adjacent to street

20’ or infill standards

B5 Rear setback

20’

B6 Rear setback adjacent to detached residential

50’

C. Accessory Structure Setbacks

S-E

C1 Front setback

20’

C2 Side setback

10’

C3 Side setback adjacent to street

20’

C4 Rear setback

10’

D. Parking Setbacks

S-E

D1 From primary and adjacent streets

5’**

D2 From adjacent residential

20’**

E. Height

S-E

E1 Principal building(s) (max)

**

E2 Accessory structure(s) (max)

15’, 1 story

F. Pedestrian Access

S-E

F1 Street-facing primary entrance along street

yes

*lots must be of a sufficient size to accommodate the proposed use and meet all subsequent development standards

**see additional development standards for proposed use

9.4.1 Intent

The intent of the special uses infill compatibility standards is to accommodate and encourage compatible development and appropriate redevelopment in existing special use areas, while reinforcing the established character of the area and mitigating adverse impacts on adjacent residential and commercial uses.

9.4.2 Applicability

  1. When indicated on the base dimensional standards chart as “infill standards”, infill development standards shall be applied unless determined to be not applicable in accordance with Section 9.4.2. The base dimensional standards of the district shall apply if infill standards are not applicable.
  2. The standards contained within this section apply to any building in an S-I and S-E district.
  3. These infill development standards do not take precedence over any requirements found in a Historic District.
  4. Front Setback
    1. The proposed building must be located within the range of setbacks, no closer than the smallest setback in the range and no further than the largest setback in the range.
    2. On an interior lot, the range of setbacks is measured on the basis of the two (2) closest lots in both directions along the primary street. This shall be considered the measurement of the block face.
    3. On a corner lot, the range of setbacks is measured on the basis of the two (2) closest lots along the primary street. This shall be considered the measure of the block face.
    4. Where the calculation cannot be applied to at least four (4) lots on an interior lot or two (2) lots on a corner lot, the building shall meet the base dimensional standards for the zoning district.
    5. Where a setback in any lot(s) used in the calculation is significantly out of the range of setbacks along the block face, the City Planner may eliminate it from the range.
  5. Side Setback
    1. The minimum side setback is equal to the average side setback of the two (2) closest lots in either direction along the block face.
    2. On a corner lot, the side setback adjacent to a street (also known as a secondary street), shall match the front setback of the two (2) closest lots along the secondary street.
    3. No setback is required to exceed twenty-five percent (25%) of the subject lot width.
    4. No structure shall be sited within ten (10) feet of an existing structure on the adjacent lot.