BASE ZONING DISTRICTS
The Industrial districts are intended to accommodate industrial park development, manufacturing, warehousing, and wholesaling in locations with good access to highways and arterial roads. The Industrial districts are intended to promote job retention and job creation and such districts are intended to promote expansion of the Town’s employment base and access to jobs in close proximity to people’s homes.
The I, Institutional district is intended to provide a transition zone between residential and business or industrial districts and to accommodate a moderate to high intensity mixture of institutional uses. Within this district, uses such as schools, hospitals, government buildings, churches, and public utility buildings may be allowed. Land designated I, Industrial District shall normally be served with public water and sewer services and has direct access to major or minor thoroughfares.
The Table of Permitted Uses Chapter 570 identifies permitted, permitted with conditional zoning, prohibited and other uses authorized within the zoning districts identified. The uses identified are subject to compliance with all other applicable standards or requirements of this ordinance.
The “R” residential zoning districts are intended to create, maintain, and promote a variety of housing opportunities for individual household and to maintain the desire physical character of the Town’s existing neighborhoods. While the districts primarily accommodate residential use types, certain nonresidential uses such as schools, churches, parks and other uses that are compatible with residential neighborhoods are also allowed.
The use table shown in Chapter 570 identifies permitted, permitted with conditional zoning, and prohibited uses within the zoning districts identified. The uses identified are subject to compliance with all other applicable standards or requirements of this ordinance.
Different development options are offered in the R districts as a way of promoting a wide variety of housing options and lifestyle choices. The development options described in this section may be used at the property owner’s election.
| Lot and Building Standards | RSF | SF-1 | SF-2 | SF-3 | SF-4 | SF-5 | MFR |
| CONVENTIONAL DEVELOPMENT | |||||||
| Lot Size | |||||||
| Lot Area (minimum sq. ft.) | 40,000 | 20,000 | 15,000 | 12,000 | 10,000 | 8,000 | NA |
| Lot Area Per Unit (minimum sq. ft.) | 40,000 | 20,000 | 15,000 | 12,000 | 10,000 | 8,000 | 3,350 |
| Lot Frontage (minimum feet) | 120 | 100 | 80 | 80 | 60 | 60 | NA |
| Lot Depth to Width Ratio (maximum) | 4 | NA | NA | NA | NA | NA | NA |
| Lot Coverage (maximum) | 24% | 24% | 35% | 35% | 50% | 50% | NA |
| Front Setback - Boulevards and Thoroughfares (minimum feet) | 50 | 50 | 40 | 40 | 40 | 30 | 30 |
| Front Setback - All Other Streets (minimum feet) | 40 | 40 | 30 | 30 | 30 | 25 | 25 |
| Rear Setback (minimum feet) | 40 | 40 | 40 | 40 | 40 | 30 | 30 |
| Side Setback (minimum feet) | 15 | 15 | 12 | 12 | 10 | 10 | 10 |
| Side Setback - Corner Lot Street Side (minimum feet) | 20 | 20 | 17 | 17 | 15 | 15 | 15 |
| Accessory Structure Setback (minimum feet from side and rear property lines) (1) | 5 | 5 | 5 | 5 | 5 | 5 | - |
| Accessory Structure Setback - Corner Lot Street Side (minimum feet from side and rear property lines) (1) | 10 | 10 | 10 | 10 | 10 | 10 | - |
| Maximum Building Height | 35 | 35 | 35 | 35 | 35 | 35 | 40 |
| CLUSTER DEVELOPMENT (* See Chapter 1210) | |||||||
| Overall Site Area | |||||||
| Site Area (minimum acres) | 10 | 10 | 10 | 10 | NA | NA | NA |
| Open Space (minimum % of site)* | 15%/20% | 15%/20% | 15%/20% | 15%/20% | NA | NA | NA |
| Site Area Per Unit (minimum sq. ft.) | 40,000 | 20,000 | 15,000 | 12,000 | NA | NA | NA |
| Lot Size | |||||||
| Lot Area (minimum sq. ft.) | 30,000 | 15,000 | 12,000 | 10,000 | NA | NA | NA |
| Lot Frontage (minimum feet) | 100 | 80 | 70 | 60 | NA | NA | NA |
| Lot Coverage (maximum) | 24% | 24% | 35% | 35% | 50% | 50% | NA |
| Front Setback - Boulevards and Thoroughfares (minimum feet) | 40 | 40 | 30 | 30 | NA | NA | NA |
| Front Setback - All Other Streets (minimum feet) | 20 | 20 | 20 | 20 | NA | NA | NA |
| Rear Setback (minimum feet) | 20 | 20 | 20 | 20 | NA | NA | NA |
| Side Setback (minimum feet) | 12 | 12 | 12 | 12 | NA | NA | See Section 1210.060 |
| Side Setback - Corner Lot Street Side (minimum feet) | 17 | 17 | 17 | 17 | NA | NA | See Section 1210.060 |
| Accessory Structure (feet from side and rear property lines) (1) | 5 | 5 | 5 | 5 | 5 | 5 | - |
| Accessory Structure - Corner Lot Street Side (feet from side and rear property lines) (1) | 10 | 10 | 10 | 10 | 10 | 10 | - |
| Maximum Building Height | 35 | 35 | 35 | 35 | NA | NA | NA |
| OPEN SPACE DEVELOPMENT | |||||||
| Overall Site Area | |||||||
| Site Area (minimum acres) | 25 | 25 | 25 | 25 | NA | NA | NA |
| Open Space (minimum % of site) | 25% | 25% | 25% | 25% | NA | NA | NA |
| Site Area Per Unit (minimum sq. ft) on Community Water and Waste Water | 20,000 | 15,000 | 12,000 | 10,000 | NA | NA | NA |
| Site Area Per Unit (minimum sq. ft) on Private Water and Waste Water | 20,000 | 15,000 | 12,000 | 10,000 | NA | NA | NA |
| Lot Size | |||||||
| Lot Area (minimum sq. ft.) | 20,000 | 15,000 | 12,000 | 10,000 | NA | NA | NA |
| Lot Frontage (minimum feet) | 100 | 75 | 60 | 60 | NA | NA | NA |
| Lot Coverage (maximum) | 24% | 24% | 35% | 35% | 50% | 50% | NA |
| Front Setback - from Boulevards and Thoroughfares (minimum feet) | 40 | 40 | 30 | 30 | NA | NA | NA |
| Front Setback - from All Other Streets (minimum feet) | 20 | 20 | 20 | 20 | NA | NA | NA |
| Rear Setback (minimum feet) | 20 | 20 | 20 | 20 | NA | NA | NA |
| Side Setback (minimum feet) | 12 | 12 | 6 | 6 | NA | NA | NA |
| Side Setback - Corner Lot Street Side (minimum feet) | 17 | 17 | 11 | 11 | NA | NA | See Section 1210.060 |
| Accessory Structure Setback (minimum feet from side and rear property lines) (1) | 5 | 5 | 5 | 5 | 5 | 5 | - |
| Accessory Structure Setback - Corner Lot Street Side (minimum feet from side and rear property lines) (1) | 10 | 10 | 10 | 10 | 10 | 10 | - |
| Maximum Building Height | 35 | 35 | 35 | 35 | NA | NA | NA |
Uses and development in R districts are subject to other standards including the following:
(See Landscaping and Screening, DIVISION 800)
(See Sign Regulation DIVISION 900)
(See Supplementary Use Regulations, DIVISION 700 )
The creation of new flag lots may be considered only in compliance with 1110.080 H.
*See Chapter 7220 for existing car wash uses within the Old Monroe Mixed Use Activity Center Overlay. New car wash uses in Mixed Use and Sub-Regional Activity Center Overlays are otherwise prohibited.
The use table shown in Chapter 570 identifies permitted, permitted with conditional zoning, and prohibited uses within the zoning districts identified. The uses identified are subject to compliance with all other applicable standards or requirements of this ordinance.
All residential and nonresidential development in business districts must comply with the lot and building standards of Table 500-2, except as otherwise expressly provided. Rules for measuring compliance with the lot and building standards established in Table 500-2 and applicable exceptions to the standards can be found in the Development Review Procedures, DIVISION 300.
| Lot and Building Standards (1) | NBD | GBD | RBD | O-NSAC, O-MUAC and O-SRAC |
| LOT SIZE | ||||
| Lot Area (minimum sq. ft.) | 6,000 | 6,000 | 8,000 | NA |
| Lot Area Per Dwelling Unit (minimum sq.ft.) | 6,000 | 6,000 | 6,000 | NA |
| Lot Width (minimum feet) | 60 | 60 | 60 | NA |
| BUILDING SETBACKS AND HEIGHT | ||||
| Front Setback (minimum feet unless range provided) (2) | 25; 15 if parking is located behind building | 25; 15 if parking is located behind building | 40; 20 if parking is located behind building | 0 -15 (max.) |
| Rear Setback - Not Abutting Residential (minimum feet) | 12.5 | 12.5 | 20 | NA |
| Rear Setback - Abutting Residential (minimum feet) | 15 | 20 | 20 | 15 |
| Side Setback - not abutting residential (minimum feet unless range provided) | 10 | 10 | 10 | 0-10 |
| Side Setback - abutting residential district (minimum feet) | 15 | 20 | 20 | 15 |
| Side Setback - abutting a street (minimum feet) | 25; 15 if parking is located behind building | 25; 15 if parking is located behind building | 40; 20 if parking is located behind building | 0-15 (max.) |
| Maximum Height (feet) | 50 | 50 | 70 | 70 (45 for single family detached & attached residential) |
| Maximum Building Area (Gross Floor Area (GFA) for individual establishments/ uses on a single building floor level) (3) | 15,000 square feet | 35,000 square feet | None | 15,000 square feet |
Uses and development in the NBD, GBD, RBD districts; Mixed Use Activity Center Overlay; and Sub-Regional Activity Center Overlay are subject to other standards including the following:
The use table shown in Chapter 570 identifies permitted, permitted with conditional zoning, and prohibited uses within the zoning districts identified. The uses identified are subject to compliance with all other applicable standards or requirements of this ordinance.
| Lot and Building Standards (Industrial and Institutional Districts) | L-I District | H-I District | I District |
| LOT SIZE | |||
| Minimum lot area (square feet) | NA | NA | NA |
| Minimum lot width (feet) | 100 | 100 | 100 |
| BUILDING SETBACKS AND HEIGHT | |||
| Front Setback (1) | 50 | 50 | 50 |
| Rear Setback - not abutting residential | 50 | 50 | 50 |
| Rear Setback - abutting residential | 60 | 60 | 60 |
| Side Setback - not abutting residential | 20 | 20 | 20 |
| Side Setback - abutting residential district | 25 | 25 | 25 |
| Maximum permitted building height | 100 | 100 | 100 |
Uses and development in I districts are subject to other standards including the following:
The use table shown in Chapter 570 identifies permitted, permitted with conditional zoning, and prohibited uses within the zoning districts identified. The uses identified are subject to compliance with all other applicable standards or requirements of this ordinance.
All institutional development must comply with the lot and building standards below and combined with the Industrial District in Table 500-3 under Section 540.030,B ("Lot and Building Standards") of Chapter 540, "Industrial Zoning Districts". Rules for measuring compliance with the lot and building standards and applicable exceptions to the standards can be found in the Development Review Procedures, DIVISION 300. Refer to Chapter 7250, "Union County Public Schools Design Standards," for public school development.
The Downtown zoning districts are intended to accommodate a mix of uses including residential, commercial, office, food, retail, and service uses. Each Downtown district provides a distinct treatment of uses based on the Downtown Master Plan.
The use table shown in Chapter 570 identifies permitted, permitted with conditional zoning, and prohibited uses within the zoning districts identified. The uses identified are subject to compliance with all other applicable standards or requirements of the ordinance.
All residential and nonresidential development in business districts must comply with the lot and building standards of Table 500-_, except as otherwise expressly provided. Rules for measuring compliance with the lot and building standards established in Table 500-4 and applicable exceptions to the standards can be found in the Development Review Procedures, DIVISION 300.
| Lot and Building Standards | DCD | DTD | DTD-R |
| LOT SIZE | |||
| Lot Area | NA | NA | NA |
| Lot Area Per Dwelling Unit (min. sq. ft.) | NA | NA | 8,000 |
| Lot Width (min. ft.) | NA | NA | 50 |
| BUILDING SETBACKS AND HEIGHT | |||
| Front Setback (min. ft.) | None | 10 | 25 |
| Rear Setback – Not Abutting Residential (min. feet) | None | 15 | 30 |
| Rear Setback – Abutting Residential (feet) | 15 max. | 30 min. | 30 min. |
| Side Setback – Not Abutting Residential (feet) | 10 max. | 10 min. | 10 min. |
| Side Setback – Abutting Residential (feet) | 15 max. | 15 min. | 15 min. |
| Side Corner (min. ft.) | None | 10 | 10 |
| Accessory Structure Setback (min. feet from side and rear property lines) (1) | 5 | 5 | 5 |
| Accessory Structure Setback - Corner Lot Street Side (min. feet from side and rear property lines) (1) | 5 | 10 | 10 |
| Maximum Height (feet) | 50 | 50 | 50 |
| Maximum Building Area (Gross Floor Area (GFA) for individual establishments/ uses on a single building floor level) (3) | 15,000 sq. ft. | 20,000 sq. ft. | NA |
Uses and development in the DCD, DTD, and DTD-R districts are subject to other applicable regulations throughout the UDO such as the following:
The use table at the link below identifies uses authorized or prohibited within the zoning districts identified in DIVISION 500. The use codes are as follows: P = Permitted Use; C = Conditional Zoning; and "-" = Prohibited Use/Not Permitted.
Click Here for Table 500-5: Table of Permitted Uses.
BASE ZONING DISTRICTS
The Industrial districts are intended to accommodate industrial park development, manufacturing, warehousing, and wholesaling in locations with good access to highways and arterial roads. The Industrial districts are intended to promote job retention and job creation and such districts are intended to promote expansion of the Town’s employment base and access to jobs in close proximity to people’s homes.
The I, Institutional district is intended to provide a transition zone between residential and business or industrial districts and to accommodate a moderate to high intensity mixture of institutional uses. Within this district, uses such as schools, hospitals, government buildings, churches, and public utility buildings may be allowed. Land designated I, Industrial District shall normally be served with public water and sewer services and has direct access to major or minor thoroughfares.
The Table of Permitted Uses Chapter 570 identifies permitted, permitted with conditional zoning, prohibited and other uses authorized within the zoning districts identified. The uses identified are subject to compliance with all other applicable standards or requirements of this ordinance.
The “R” residential zoning districts are intended to create, maintain, and promote a variety of housing opportunities for individual household and to maintain the desire physical character of the Town’s existing neighborhoods. While the districts primarily accommodate residential use types, certain nonresidential uses such as schools, churches, parks and other uses that are compatible with residential neighborhoods are also allowed.
The use table shown in Chapter 570 identifies permitted, permitted with conditional zoning, and prohibited uses within the zoning districts identified. The uses identified are subject to compliance with all other applicable standards or requirements of this ordinance.
Different development options are offered in the R districts as a way of promoting a wide variety of housing options and lifestyle choices. The development options described in this section may be used at the property owner’s election.
| Lot and Building Standards | RSF | SF-1 | SF-2 | SF-3 | SF-4 | SF-5 | MFR |
| CONVENTIONAL DEVELOPMENT | |||||||
| Lot Size | |||||||
| Lot Area (minimum sq. ft.) | 40,000 | 20,000 | 15,000 | 12,000 | 10,000 | 8,000 | NA |
| Lot Area Per Unit (minimum sq. ft.) | 40,000 | 20,000 | 15,000 | 12,000 | 10,000 | 8,000 | 3,350 |
| Lot Frontage (minimum feet) | 120 | 100 | 80 | 80 | 60 | 60 | NA |
| Lot Depth to Width Ratio (maximum) | 4 | NA | NA | NA | NA | NA | NA |
| Lot Coverage (maximum) | 24% | 24% | 35% | 35% | 50% | 50% | NA |
| Front Setback - Boulevards and Thoroughfares (minimum feet) | 50 | 50 | 40 | 40 | 40 | 30 | 30 |
| Front Setback - All Other Streets (minimum feet) | 40 | 40 | 30 | 30 | 30 | 25 | 25 |
| Rear Setback (minimum feet) | 40 | 40 | 40 | 40 | 40 | 30 | 30 |
| Side Setback (minimum feet) | 15 | 15 | 12 | 12 | 10 | 10 | 10 |
| Side Setback - Corner Lot Street Side (minimum feet) | 20 | 20 | 17 | 17 | 15 | 15 | 15 |
| Accessory Structure Setback (minimum feet from side and rear property lines) (1) | 5 | 5 | 5 | 5 | 5 | 5 | - |
| Accessory Structure Setback - Corner Lot Street Side (minimum feet from side and rear property lines) (1) | 10 | 10 | 10 | 10 | 10 | 10 | - |
| Maximum Building Height | 35 | 35 | 35 | 35 | 35 | 35 | 40 |
| CLUSTER DEVELOPMENT (* See Chapter 1210) | |||||||
| Overall Site Area | |||||||
| Site Area (minimum acres) | 10 | 10 | 10 | 10 | NA | NA | NA |
| Open Space (minimum % of site)* | 15%/20% | 15%/20% | 15%/20% | 15%/20% | NA | NA | NA |
| Site Area Per Unit (minimum sq. ft.) | 40,000 | 20,000 | 15,000 | 12,000 | NA | NA | NA |
| Lot Size | |||||||
| Lot Area (minimum sq. ft.) | 30,000 | 15,000 | 12,000 | 10,000 | NA | NA | NA |
| Lot Frontage (minimum feet) | 100 | 80 | 70 | 60 | NA | NA | NA |
| Lot Coverage (maximum) | 24% | 24% | 35% | 35% | 50% | 50% | NA |
| Front Setback - Boulevards and Thoroughfares (minimum feet) | 40 | 40 | 30 | 30 | NA | NA | NA |
| Front Setback - All Other Streets (minimum feet) | 20 | 20 | 20 | 20 | NA | NA | NA |
| Rear Setback (minimum feet) | 20 | 20 | 20 | 20 | NA | NA | NA |
| Side Setback (minimum feet) | 12 | 12 | 12 | 12 | NA | NA | See Section 1210.060 |
| Side Setback - Corner Lot Street Side (minimum feet) | 17 | 17 | 17 | 17 | NA | NA | See Section 1210.060 |
| Accessory Structure (feet from side and rear property lines) (1) | 5 | 5 | 5 | 5 | 5 | 5 | - |
| Accessory Structure - Corner Lot Street Side (feet from side and rear property lines) (1) | 10 | 10 | 10 | 10 | 10 | 10 | - |
| Maximum Building Height | 35 | 35 | 35 | 35 | NA | NA | NA |
| OPEN SPACE DEVELOPMENT | |||||||
| Overall Site Area | |||||||
| Site Area (minimum acres) | 25 | 25 | 25 | 25 | NA | NA | NA |
| Open Space (minimum % of site) | 25% | 25% | 25% | 25% | NA | NA | NA |
| Site Area Per Unit (minimum sq. ft) on Community Water and Waste Water | 20,000 | 15,000 | 12,000 | 10,000 | NA | NA | NA |
| Site Area Per Unit (minimum sq. ft) on Private Water and Waste Water | 20,000 | 15,000 | 12,000 | 10,000 | NA | NA | NA |
| Lot Size | |||||||
| Lot Area (minimum sq. ft.) | 20,000 | 15,000 | 12,000 | 10,000 | NA | NA | NA |
| Lot Frontage (minimum feet) | 100 | 75 | 60 | 60 | NA | NA | NA |
| Lot Coverage (maximum) | 24% | 24% | 35% | 35% | 50% | 50% | NA |
| Front Setback - from Boulevards and Thoroughfares (minimum feet) | 40 | 40 | 30 | 30 | NA | NA | NA |
| Front Setback - from All Other Streets (minimum feet) | 20 | 20 | 20 | 20 | NA | NA | NA |
| Rear Setback (minimum feet) | 20 | 20 | 20 | 20 | NA | NA | NA |
| Side Setback (minimum feet) | 12 | 12 | 6 | 6 | NA | NA | NA |
| Side Setback - Corner Lot Street Side (minimum feet) | 17 | 17 | 11 | 11 | NA | NA | See Section 1210.060 |
| Accessory Structure Setback (minimum feet from side and rear property lines) (1) | 5 | 5 | 5 | 5 | 5 | 5 | - |
| Accessory Structure Setback - Corner Lot Street Side (minimum feet from side and rear property lines) (1) | 10 | 10 | 10 | 10 | 10 | 10 | - |
| Maximum Building Height | 35 | 35 | 35 | 35 | NA | NA | NA |
Uses and development in R districts are subject to other standards including the following:
(See Landscaping and Screening, DIVISION 800)
(See Sign Regulation DIVISION 900)
(See Supplementary Use Regulations, DIVISION 700 )
The creation of new flag lots may be considered only in compliance with 1110.080 H.
*See Chapter 7220 for existing car wash uses within the Old Monroe Mixed Use Activity Center Overlay. New car wash uses in Mixed Use and Sub-Regional Activity Center Overlays are otherwise prohibited.
The use table shown in Chapter 570 identifies permitted, permitted with conditional zoning, and prohibited uses within the zoning districts identified. The uses identified are subject to compliance with all other applicable standards or requirements of this ordinance.
All residential and nonresidential development in business districts must comply with the lot and building standards of Table 500-2, except as otherwise expressly provided. Rules for measuring compliance with the lot and building standards established in Table 500-2 and applicable exceptions to the standards can be found in the Development Review Procedures, DIVISION 300.
| Lot and Building Standards (1) | NBD | GBD | RBD | O-NSAC, O-MUAC and O-SRAC |
| LOT SIZE | ||||
| Lot Area (minimum sq. ft.) | 6,000 | 6,000 | 8,000 | NA |
| Lot Area Per Dwelling Unit (minimum sq.ft.) | 6,000 | 6,000 | 6,000 | NA |
| Lot Width (minimum feet) | 60 | 60 | 60 | NA |
| BUILDING SETBACKS AND HEIGHT | ||||
| Front Setback (minimum feet unless range provided) (2) | 25; 15 if parking is located behind building | 25; 15 if parking is located behind building | 40; 20 if parking is located behind building | 0 -15 (max.) |
| Rear Setback - Not Abutting Residential (minimum feet) | 12.5 | 12.5 | 20 | NA |
| Rear Setback - Abutting Residential (minimum feet) | 15 | 20 | 20 | 15 |
| Side Setback - not abutting residential (minimum feet unless range provided) | 10 | 10 | 10 | 0-10 |
| Side Setback - abutting residential district (minimum feet) | 15 | 20 | 20 | 15 |
| Side Setback - abutting a street (minimum feet) | 25; 15 if parking is located behind building | 25; 15 if parking is located behind building | 40; 20 if parking is located behind building | 0-15 (max.) |
| Maximum Height (feet) | 50 | 50 | 70 | 70 (45 for single family detached & attached residential) |
| Maximum Building Area (Gross Floor Area (GFA) for individual establishments/ uses on a single building floor level) (3) | 15,000 square feet | 35,000 square feet | None | 15,000 square feet |
Uses and development in the NBD, GBD, RBD districts; Mixed Use Activity Center Overlay; and Sub-Regional Activity Center Overlay are subject to other standards including the following:
The use table shown in Chapter 570 identifies permitted, permitted with conditional zoning, and prohibited uses within the zoning districts identified. The uses identified are subject to compliance with all other applicable standards or requirements of this ordinance.
| Lot and Building Standards (Industrial and Institutional Districts) | L-I District | H-I District | I District |
| LOT SIZE | |||
| Minimum lot area (square feet) | NA | NA | NA |
| Minimum lot width (feet) | 100 | 100 | 100 |
| BUILDING SETBACKS AND HEIGHT | |||
| Front Setback (1) | 50 | 50 | 50 |
| Rear Setback - not abutting residential | 50 | 50 | 50 |
| Rear Setback - abutting residential | 60 | 60 | 60 |
| Side Setback - not abutting residential | 20 | 20 | 20 |
| Side Setback - abutting residential district | 25 | 25 | 25 |
| Maximum permitted building height | 100 | 100 | 100 |
Uses and development in I districts are subject to other standards including the following:
The use table shown in Chapter 570 identifies permitted, permitted with conditional zoning, and prohibited uses within the zoning districts identified. The uses identified are subject to compliance with all other applicable standards or requirements of this ordinance.
All institutional development must comply with the lot and building standards below and combined with the Industrial District in Table 500-3 under Section 540.030,B ("Lot and Building Standards") of Chapter 540, "Industrial Zoning Districts". Rules for measuring compliance with the lot and building standards and applicable exceptions to the standards can be found in the Development Review Procedures, DIVISION 300. Refer to Chapter 7250, "Union County Public Schools Design Standards," for public school development.
The Downtown zoning districts are intended to accommodate a mix of uses including residential, commercial, office, food, retail, and service uses. Each Downtown district provides a distinct treatment of uses based on the Downtown Master Plan.
The use table shown in Chapter 570 identifies permitted, permitted with conditional zoning, and prohibited uses within the zoning districts identified. The uses identified are subject to compliance with all other applicable standards or requirements of the ordinance.
All residential and nonresidential development in business districts must comply with the lot and building standards of Table 500-_, except as otherwise expressly provided. Rules for measuring compliance with the lot and building standards established in Table 500-4 and applicable exceptions to the standards can be found in the Development Review Procedures, DIVISION 300.
| Lot and Building Standards | DCD | DTD | DTD-R |
| LOT SIZE | |||
| Lot Area | NA | NA | NA |
| Lot Area Per Dwelling Unit (min. sq. ft.) | NA | NA | 8,000 |
| Lot Width (min. ft.) | NA | NA | 50 |
| BUILDING SETBACKS AND HEIGHT | |||
| Front Setback (min. ft.) | None | 10 | 25 |
| Rear Setback – Not Abutting Residential (min. feet) | None | 15 | 30 |
| Rear Setback – Abutting Residential (feet) | 15 max. | 30 min. | 30 min. |
| Side Setback – Not Abutting Residential (feet) | 10 max. | 10 min. | 10 min. |
| Side Setback – Abutting Residential (feet) | 15 max. | 15 min. | 15 min. |
| Side Corner (min. ft.) | None | 10 | 10 |
| Accessory Structure Setback (min. feet from side and rear property lines) (1) | 5 | 5 | 5 |
| Accessory Structure Setback - Corner Lot Street Side (min. feet from side and rear property lines) (1) | 5 | 10 | 10 |
| Maximum Height (feet) | 50 | 50 | 50 |
| Maximum Building Area (Gross Floor Area (GFA) for individual establishments/ uses on a single building floor level) (3) | 15,000 sq. ft. | 20,000 sq. ft. | NA |
Uses and development in the DCD, DTD, and DTD-R districts are subject to other applicable regulations throughout the UDO such as the following:
The use table at the link below identifies uses authorized or prohibited within the zoning districts identified in DIVISION 500. The use codes are as follows: P = Permitted Use; C = Conditional Zoning; and "-" = Prohibited Use/Not Permitted.
Click Here for Table 500-5: Table of Permitted Uses.