60 LOT AND STRUCTURE DIMENSIONAL REQUIREMENTS
Chart 1 Dimensional Requirements | ||||||
|---|---|---|---|---|---|---|
Minimum Setbacks | ||||||
District | Min. Sq. Ft. | Min. Width | Front | Rear | Side | Street |
R-R | 20,000 | 100′ | 40′ | 40′ | 10′ | 25′ |
R-1 | 8,000 | 75′ | 20′ | 20′ | 5′ | 20′ |
R-2 | 5,000 | 50′ | 20′ | 20′ | 5′ | 20′ |
R-2D Single-family Duplex | 5,000 7,500 | 50′ 75′ | 20′ 20′ | 20′ 20′ | 5′ 5′ | 20′ 20′ |
R-3 | 5,000 | 50′ | 20′ | 20′ | 5′ | 20′ |
R-4 | none | 50′ | 20′ | 20′ | 5′ | 20′ |
C-1 | none | none | see Exception 4 | |||
C-19 | 5,000 | 50′ | 20′ | 20′ | 5′ | 20′ |
C-2 | 5,000 | 50′ | see Exceptions 4 and 5 | |||
C-29 | 5,000 | 50′ | 20′ | 20′ | 5′ | 20′ |
C-3 | 5,000 | 50′ | see Exceptions 4 and 5 | |||
C-39 | 5,000 | 50′ | 20′ | 20′ | 5′ | 20′ |
I-1 | 5,000* | 50′ | see Exceptions 4 and 5 | |||
I-2 | 5,000* | 50′ | see Exceptions 4 and 5 | |||
Conservancy | see Exception 7 | |||||
*Smaller lot sizes can be achieved if done by PUD. |
Chart 2 Height, Bulk and Density Requirements | ||||
|---|---|---|---|---|
District | Max. Height | Min. Floor Area | Max. Density* | Max. Lot Coverage |
R-R | 35′ | 1200 sq. ft. | 2.8 DU/acre | 20% |
R-1 | 35′ | 700 sq. ft. | 6.5 DU/acre | 35% |
R-2 | 35′ | 700 sq. ft. | 10.4 DU/acre | 35% |
R-3 | 35′ | 700 sq. ft. | 10.4 DU/acre | 35% |
R-4 | 35′ | 700 sq. ft. | 18.0 DU/acre | 40% |
C-1 | 50′ | none | none | none |
C-15 | 50′ | 700 sq. ft. | 18.0 DU/acre | 80% |
C-2 | 50′ | none | none | none |
C-25 | 50′ | 700 sq. ft. | 9-18 DU/acre | 40% |
C-3 | 50′ | none | none | none |
C-35 | 50′ | 700 sq. ft. | 9-18 DU/acre | 40% |
I-1 | none | none | none | none |
I-2 | none | none | none | none |
Conservancy | see Exception 4 | |||
*maximum densities may be reached only by PUD (planned unit development). |
60 LOT AND STRUCTURE DIMENSIONAL REQUIREMENTS
Chart 1 Dimensional Requirements | ||||||
|---|---|---|---|---|---|---|
Minimum Setbacks | ||||||
District | Min. Sq. Ft. | Min. Width | Front | Rear | Side | Street |
R-R | 20,000 | 100′ | 40′ | 40′ | 10′ | 25′ |
R-1 | 8,000 | 75′ | 20′ | 20′ | 5′ | 20′ |
R-2 | 5,000 | 50′ | 20′ | 20′ | 5′ | 20′ |
R-2D Single-family Duplex | 5,000 7,500 | 50′ 75′ | 20′ 20′ | 20′ 20′ | 5′ 5′ | 20′ 20′ |
R-3 | 5,000 | 50′ | 20′ | 20′ | 5′ | 20′ |
R-4 | none | 50′ | 20′ | 20′ | 5′ | 20′ |
C-1 | none | none | see Exception 4 | |||
C-19 | 5,000 | 50′ | 20′ | 20′ | 5′ | 20′ |
C-2 | 5,000 | 50′ | see Exceptions 4 and 5 | |||
C-29 | 5,000 | 50′ | 20′ | 20′ | 5′ | 20′ |
C-3 | 5,000 | 50′ | see Exceptions 4 and 5 | |||
C-39 | 5,000 | 50′ | 20′ | 20′ | 5′ | 20′ |
I-1 | 5,000* | 50′ | see Exceptions 4 and 5 | |||
I-2 | 5,000* | 50′ | see Exceptions 4 and 5 | |||
Conservancy | see Exception 7 | |||||
*Smaller lot sizes can be achieved if done by PUD. |
Chart 2 Height, Bulk and Density Requirements | ||||
|---|---|---|---|---|
District | Max. Height | Min. Floor Area | Max. Density* | Max. Lot Coverage |
R-R | 35′ | 1200 sq. ft. | 2.8 DU/acre | 20% |
R-1 | 35′ | 700 sq. ft. | 6.5 DU/acre | 35% |
R-2 | 35′ | 700 sq. ft. | 10.4 DU/acre | 35% |
R-3 | 35′ | 700 sq. ft. | 10.4 DU/acre | 35% |
R-4 | 35′ | 700 sq. ft. | 18.0 DU/acre | 40% |
C-1 | 50′ | none | none | none |
C-15 | 50′ | 700 sq. ft. | 18.0 DU/acre | 80% |
C-2 | 50′ | none | none | none |
C-25 | 50′ | 700 sq. ft. | 9-18 DU/acre | 40% |
C-3 | 50′ | none | none | none |
C-35 | 50′ | 700 sq. ft. | 9-18 DU/acre | 40% |
I-1 | none | none | none | none |
I-2 | none | none | none | none |
Conservancy | see Exception 4 | |||
*maximum densities may be reached only by PUD (planned unit development). |