A. Development Standards for New Construction Accessory Dwelling Units.
1. Occupancy. The following occupancy standards shall be applied to every ADU and JADU in the city:
a. Short-Term Rental Use Prohibited. In no case shall a short-term rental use of less than thirty (30) days be permitted in JADUs or ADUs; these units shall be occupied for terms longer than thirty (30) days.
b. Sale. ADUs and JADUS shall not be sold separately from the primary unit.
i. Exception. An ADU can be sold or conveyed separately from the primary residence to a qualified buyer if the property was built or developed by a qualified nonprofit corporation and all provisions of California Government Code Section 65852.26 are met.
c. Owner Residency. The following requirements apply to all JADUs. Additionally, the following requirements apply to all ADUs except those permitted between January 1, 2020 and January 1, 2025.
i. Unless owned by a government agency, land trust, or public or nonprofit housing organization, the property owner shall permanently reside, as evidenced by a homeowner's property tax exemption, on the parcel in either the primary unit, ADU, or JADU.
ii. A deed restriction shall be recorded against the title of the property that contains the ADU or JADU, prior to issuance of a building permit. Such deed restriction shall stipulate the owner residency requirement and that the ADU or JADU cannot be sold separately.
2. Minimum Parcel Size. No minimum parcel size shall be required to establish an ADU or JADU.
a. Minimum unit size, JADU or ADU: One hundred fifty (150) square feet ("efficiency unit" per California Health and Safety Code section 17958.1).
b. Maximum unit size, JADU: Five hundred (500) square feet.
c. Maximum unit size, ADU:
ii. New Construction ADU: Eight hundred fifty (850) square feet (studio or one (1) bedroom), one thousand (1,000) square feet (two (2) bedrooms), or fifty percent (50%) of the primary unit, whichever is smaller.
iii. Regardless of subsections i. - ii. of this section and other site standards such as private open space or vegetation, an ADU must be allowed to be at least eight hundred (800) square feet.
a. JADUs and Conversion ADUs. Setbacks shall be sufficient for fire safety in conformance with the Building Code and Fire Code. Additions up to one hundred fifty (150) square feet shall meet setback requirements for new construction ADUs.
b. New Construction ADUs. ADUs shall comply with front and street side setbacks for the applicable zoning district. Minimum side and rear setbacks shall be four (4) feet or the setback for the applicable zoning district, whichever is less, with the following exceptions:
i. No setback shall be required for an existing living area or accessory structure, or a structure constructed in the same location and to the same dimensions as an existing structure that is converted to an ADU or to a portion of an ADU.
ii. ADUs subject to environmental buffers and constraints under the California Coastal Act.
a. JADUs and Conversion ADUs. Additions of up to one hundred fifty (150) square feet shall meet height requirements for new construction ADUs.
b. New Construction ADUs. Height shall be no greater than permitted in to the applicable zoning district height standards, dependent upon ADU configuration, but not less than sixteen (16) feet unless otherwise identified in the City's Local Coastal Plan in order to protect coastal resources.
6. Lot Coverage and Maximum Building Area.
a. JADUs and Conversion ADUs: Additions of up to one hundred fifty (150) square feet shall meet lot coverage and maximum building area requirements for new construction ADUs.
b. New Construction ADUs: Lot coverage and maximum building area shall comply with the standard for the applicable zoning district, except that an ADU of up to eight hundred (800) square feet shall be allowed, regardless of lot coverage and maximum building area.
7. Design. The design, materials, and color of a new construction ADU shall be compatible with that of the primary unit.
8. Number of Bedrooms. There is no maximum number of bedrooms for an ADU or JADU.
9. Utility Services. The primary unit, ADU, and JADU may be served from the same gas, electricity, and water lines, at the discretion of the property owner. No development shall be approved that would exceed the capacity of the municipal utility systems. Specifically, all applications received for ADUs and JADUs shall be accompanied by evidence provided by the municipal utility provider that there are adequate services/capacities to serve the proposed development.
10. Water Conservation. All plumbing fixtures in the primary unit, an ADU, and a JADU must meet current Building Energy Efficiency Standards - Title 24 requirements for water conservation.
11. Consistency with Codes. New development shall comply with all local, state, or federal regulations that apply to the property, including the applicable requirements of the general plan/local coastal plan and certified zoning ordinance. (Ord. O-2021-001 § 1 (part), 2021)