Zoneomics Logo
search icon

Piscataway City Zoning Code

§ 21-1010.1-3

Noise and Vibration.

[1972 Code § 21-1010.1-3]
All uses and activities shall comply with applicable noise and vibration standards of the State of New Jersey including the following:
No sound from any industrial operation which, when measured at any residential property line, is in excess of any of the following:
a. 
From 7:00 a.m. to 10:00 p.m.:
1. 
Continuous airborne sound which has sound level in excess of 65 dBA; or
2. 
Continuous airborne sound which has an octave band sound pressure level in decibels which exceeds the values listed below in one or more octave bands:
Octave Band Center Frequency
(Hz)
Octave Band Sound Pressure Level
(dB)
31.5
96
63
82
125
74
250
67
500
63
1,000
60
2,000
57
4,000
55
8,000
53
or;
3. 
Impulsive sound in air which has an impulsive sound level in excess of 80 decibels.
b. 
From 10:00 p.m. to 7:00 a.m.;
1. 
Continuous airborne sound which has a sound level in excess of 50 dBA; or
2. 
Continuous airborne sound which has an octave band sound pressure level in decibels which exceeds the values listed below in one or more octave bands:
Octave Band Center Frequency
(Hz)
Octave Band Sound Pressure Level
(dB)
31.5
86
63
71
125
61
250
53
500
48
1,000
45
2,000
42
4,000
40
8,000
38
Or;
3. 
Impulsive sound in air which has an impulsive sound level in excess of 80 decibels.
c. 